MS.CR.090 Emergency Generator - Drass Diving System€¦ · MS.CR.090 Emergency Generator The main...

4
The Drass Emergency Generator is a modular unit, designed mainly to support the operation of the Drass 900 Series Modular Saturation System and 700 Series Modular Surface Diving System. The generator set is installed in a 20ft container holding DNV Certification. The start system is air-driven in order to avoid electrical battery maintenance and related potential safety issues. The Emergency Generator can be operated as a harbor auxiliary generator, making use of the complete diagnostic system which is not usually provided in a regular emergency generator. The Generator should be connected to a switchboard with at least one protection switch. In case of emergency the switch receive, from the system emergency switchboard, a signal activating in this way the generator. Emergency Generator Drass Tecnologie Sottomarine MS.CR.090

Transcript of MS.CR.090 Emergency Generator - Drass Diving System€¦ · MS.CR.090 Emergency Generator The main...

Page 1: MS.CR.090 Emergency Generator - Drass Diving System€¦ · MS.CR.090 Emergency Generator The main features are as follows: ... IMO’s circular MSC/Circ. 860 and also with EN 12079

The Drass Emergency Generator is a modular unit, designed mainly to support the operation of the Drass 900 Series Modular Saturation System and 700 Series Modular Surface Diving System.The generator set is installed in a 20ft container holding DNV Certification.The start system is air-driven in order to avoid electrical battery maintenance and related potential safety issues.The Emergency Generator can be operated as a harbor auxiliary generator, making use of the complete diagnostic system which is not usually provided in a regular emergency generator. The Generator should be connected to a switchboard with at least one protection switch.In case of emergency the switch receive, from the system emergency switchboard, a signal activating in this way the generator.

Emergency Generator

DrassTecnologie Sottomarine

MS.CR.090

Page 2: MS.CR.090 Emergency Generator - Drass Diving System€¦ · MS.CR.090 Emergency Generator The main features are as follows: ... IMO’s circular MSC/Circ. 860 and also with EN 12079

MS.CR.090 Emergency Generator

The main features are as follows:

Electrical power generation from 550Kw / 650Kw / 750Kw / 900Kw, 440V 3Phases 60HzAuxiliary power generation 125KVA/230V/3 Phases 60HzAir start systemExternal fuel supply through sidewall inletSound level: 78 -80 dB(A)Installed in a modified 20ft high cube container.

Classification: Notation :DNV AUT-UMSDNV certificate :for diesel engine and generatorIMO certificate :included

Page 3: MS.CR.090 Emergency Generator - Drass Diving System€¦ · MS.CR.090 Emergency Generator The main features are as follows: ... IMO’s circular MSC/Circ. 860 and also with EN 12079

Emergency GeneratorContainerization:

The module is equipped with a CATERPILLAR Generator, which provides all the reliability and safety features requested by the offshore standards.The main characteristics of the container for offshore and maritime use (option 1) are the following:

1.Containers comply with DNV 2.7-1, 2.7-2 & 2.7-3, the guidelines in IMO’s circular MSC/Circ. 860 and also with EN 12079 points 1 and 2 respectively.2.All Modules defined as “ Units for Transportation Offshore” are portable units with a maximum gross mass not exceeding 50,000kg. The modules are for repeated or single use with a primary service function, handled in open seas, to, from or between fixed and/or floating offshore installations and ships.3.The Modules are designed with top and bottom side & end rails, corner posts, pad eyes and fork lift pockets. They are load carrying and support frames and load carrying panels. At the very least they are supplied with a minimum of 2 Escape Doors, wall and roof panels, covers on skid, panel stiffeners and corrugations and internal securing points.4.All containers have a minimum of two Interface Panels for Hose connections and Electrical socket/plug connectors. The electrical signal connectors are IP68 and the power socket/plug are for marine use. Above 63 A all sockets have disconnection equipment. The containers have a Flammable Gas & Smoke Detection System and Ventilation / Conditioning System. 5.The containers have an Air Conditioning System.

Types of Generators

Technical Data: (for all types of Generators)

Lenght Width Height

mmmmmm

60582438

2891

Code

MS.CR.091

Power

eKw550eKw650eKw750

eKw900

Weight9800 kg

13150 kg14350 kg

15500 kg

MS.CR.092 MS.CR.093 MS.CR.094

Main Dimmension: (for all types of Generators)

Start Fuel tank capacity (External fuel supply) Sound Level

Air system

1500 litres

78 - 80 dB (A)

20 ft containerPackaged

Page 4: MS.CR.090 Emergency Generator - Drass Diving System€¦ · MS.CR.090 Emergency Generator The main features are as follows: ... IMO’s circular MSC/Circ. 860 and also with EN 12079

DRASSVia Padre Nicola Magri, 112, 57121 – Livorno, ItalyPhone +39 (0) 586 421221 Fax +39 (0) 586 421223em@il: [email protected]

DrassTecnologie Sottomarine

Emergency Generator Internal View

Emergency Generator Side View