MSC - LeMessurier · The new design successfully integrates the old and ... The structure was...

8
MODERN STEEL CONSTRUCTION IN THIS ISSUE Modular Building BIM in the Fab Shop High-Strength Bolts MSC July 2012

Transcript of MSC - LeMessurier · The new design successfully integrates the old and ... The structure was...

MODERN STEEL CONSTRUCTION

IN THIS ISSUE

Modular BuildingBIM in the Fab ShopHigh-Strength Bolts

MSC July 2012

4 MODERN STEEL CONSTRUCTION JULY 2012

MODERN STEEL CONSTRUCTION (Volume 52, Number 7. ISSN (print) 0026-8445: ISSN (online) 1945-0737. Published monthly by the American Institute of Steel Construction (AISC), One E. Wacker Dr., Suite 700, Chicago, IL 60601. Subscriptions: Within the U.S.—single issues $6.00; 1 year, $44; 3 years $120. Outside the U.S.—single issues $9.00; 1 year $88; 3 years $216. Periodicals postage paid at Chicago, IL and at additional mailing offices. Postmaster: Please send address changes to MODERN STEEL CONSTRUCTION, One East Wacker Dr., Suite 700, Chicago, IL 60601.

AISC does not approve, disapprove, or guarantee the validity or accuracy of any data, claim, or opinion appearing under a byline or obtained or quoted from an acknowledged source. Opinions are those of the writers and AISC is not responsible for any statement made or opinions expressed in MODERN STEEL CONSTRUCTION. All rights reserved. Materials may not be reproduced without written permission, except for noncommercial educational purposes where fewer than 25 photocopies are being reproduced. The AISC and MSC logos are registered trademarks of AISC.

July 2012

ON THE COVER: The Tufts University School of Dental Medicine in downtown Boston, p. 34. (Photo: ©2012 Warren Patterson, Warren Patterson Photography)

26 Early to the PartyBY MARTIN ANDERSONUsing a kit-of-parts approach, the Golden Gate Bridge’s welcome center comes together in time for a big birthday bash.

30 The Star of Symphony ParkBY DAVID A. PLATTEN, P.E., ABHIJIT SHAH, P.E.,

AND JENNIFER E. RIDD, P.E.Creative cantilevers bring the audience as close to the stage as possible in the brand-new Smith Center for the Performing Arts.

34 High FiveBY ERIC M. HINES, P.E., PH.D., MYSORE V.

RAVINDRA, P.E., NATHAN C. ROY, P.E., ANDGREGORY D. SHREVE, P.E.

An urban university building grows upward by five floors to accommodate its growing programs.

40 It Takes a VillageBY J. BENJAMIN ALPER, P.E., WITH CAWSIE

JIJINA, P.E., AND FORTUNATO ORLANDO, P.E.New Brunswick’s new transit village creates a smart new crossroads for the city and the area.

44 Raising the DeadBY DAN PUTNAM, S.E., P.E.Long-span office space brings new life—and higher leases—to an urban garage that had fallen out of favor.

48 Sorting it OutBY D. MATTHEW STUART, S.E., P.E., AND

MATTHEW CORNMAN, P.E.The recent structural expansion of a package sorting facility didn’t get in the way of business as usual.

52 Anything but RedundantBY HONGZHI ZHANG, P.E., PH.D.A Washington flyover curves through a tight construction window using a non-redundant steel plate girder system.

56 A Model ApproachBY CHRIS MOORMoving to a model-based process for shop drawing review and approval in the structural steel industry.

steelwise

16 Designing Welds for Skewed Shear TabsBY CARLO LINI, P.E.How to choose the best welding option for skewed single-plate shear tabs.

product expert series22 Twists and Turns

BY ROBERT E. SHAW, JR., P.E.The latest from the world of high-strength bolting.

business issues

24 Leverage Your Nervous Energy!BY ANNE SCARLETTA myriad of tips for converting anxiety into positive energy.

people to know66 Around the World

Over the years, Jim Stori has fabricated a lot of steel—and seen a lot of the planet.

columnsfeatures

departments6 EDITOR’S NOTE

9 STEEL INTERCHANGE

12 STEEL QUIZ

60 NEWS & EVENTS

resources64 MARKETPLACE

64 ADVERTISER LIST

65 EMPLOYMENT

in every issue

30

52

34 MODERN STEEL CONSTRUCTION JULY 2012

SOMETIMES, THE ONLY WAY to go is up.This is especially the case for facilities in dense, urban areas

that find they need more space.The Tufts University School of Dental Medicine in down-

town Boston recently added two new clinical patient floors, an enlarged simulation lab and teaching facilities for students, as well as a continuing education conference center and admin-istrative offices. And it did it by expanding upward, adding 105,000 sq. ft in five stories on top of its existing 10-story struc-ture built in 1972.

The need for more space presented a compelling architec-tural challenge to integrate a prominent new steel-framed addi-tion with the original building’s aging precast concrete exteri-or—and one that would allow the existing teaching and clinical spaces to remain in use during all phases of the project. Tufts turned to architect ARC/Architectural Resources Cambridge

to develop a new exterior vision for the building and the school. The expansion created a distinctive new image for the school, which marks the gateway to the Tufts Health Science Campus.

The new design successfully integrates the old and the new by extending the new façade down the prominent northwest corner of the building to the ground-level entry, fusing the new design with the existing building. A horizontal “bump-out” cantilevers 8 ft from the building’s west face to compliment the vertical expansion of the existing building. The updated vestibule, entrance canopy and stone façade add to the new image of the building, creating a positive first impression for visitors and students. Structural fram-ing and precast panels at the northwest stair were removed two stories down to the ninth floor and replaced with a seven-story glass-enclosed orange metal-clad stair with exposed round HSS 12.75-in. framing. Visible from street level at night, the stairwell serves as a focal point for the building. The existing precast panels

An urban university building

grows upward by five floors

to accommodate its

growing programs.

BY ERIC M. HINES, P.E., PH.D., MYSORE V. RAVINDRA, P.E.,NATHAN C. ROY, P.E., AND GREGORY D. SHREVE, P.E.

High Five

©2012 W

arren Patterson, Warren Patterson Photog

raphy

JULY 2012 MODERN STEEL CONSTRUCTION 35

at the northwest corner were clad with metal panels to connect the new expansion with updates at the street level.

The five-story expansion contains floor-to-ceiling windows, allowing natural light to penetrate deep inside the 92-ft-wide by 245-ft-long structure, and provides sprawling views of Boston. The incorporation of two internal stairwells in the expanded sec-tion, between the 12th and 13th floors and the 14th and 15th

floors, allows users to easily flow from one floor to the next and promotes collaboration and interaction between the educational and clinical floors.

A Matter of LoadThe existing 10-story, 180,000-sq.-ft building was designed

by The Architects’ Collaborative (TAC) for a site that is now

Eric M. Hines is a principal with LeMessurier Consul-tants, Inc. and a professor of practice at Tufts University. Mysore V. Ravindra is chair-man of LeMessurier. NathanC. Roy is a structural engi-neer with LeMessurier and an instructor at the Boston Architectural College. Greg-ory D. Shreve is a vice pres-ident with LeMessurier.

A new column at an existing offset column splice.

The northwest stair of the building is a key architectural component of the expanded structure.

The expansion added five steel-framed stories onto an existing 10-story building.

©Alonso Nichols,Tufts University

Nat

han

Roy,

LeM

essu

rier

Con

sulta

nts

Nat

han

Roy,

LeM

essu

rier

Con

sulta

nts

36 MODERN STEEL CONSTRUCTION JULY 2012

bounded by two buildings, two busy streets and a subway tunnel. Although the original building had been engineered to accom-modate future levels, substantial changes in wind and seismic loads complicated the question of how many stories could be added to the structure without disturbing building operations.

Tufts University approached LeMessurier Consultants to ask whether a vertical expansion of the building would be pos-sible, as they had received a report by prior consultants stating that expansion would not be feasible due to significant changes in the building codes and a lack of detailed information on the pile foundations supporting the building. LeMessurier encour-aged the University to reconsider this conclusion in light of a more detailed study that included sophisticated conceptual and computational models and an in-situ exploration of existing

conditions to determine the precise level of upgrade required for existing members and details. In the end, five stories was deemed the optimal expansion size in order to minimize the required structural strengthening of the existing structure.

The structure was originally designed with braced frames in the short direction and moment frames in the long direction to resist 20-psf uniform wind load. The original building was 154 ft high, and the original base shear due to wind was 733 kips in the short direction. As originally conceived, the addition of five new 14-ft-high stories, plus a 20-ft wind screen, would increase the height to 244 ft, resulting in a total wind load of 1,160 kips in the short direction. The governing code (Massachusetts State Building Code, 6th Edition) for the expansion required wind loads that exceeded the original code loads by 23%. Detailed elastic modeling of the expanded structure demonstrated that this difference could be accommodated with an allowable stress increase of one-third in the members and connections. Results were similar for the moment frames in the long direction.

While wind controlled the design of braces and their con-nections, seismic forces governed the column splices under overturning forces. The code required amplification of the col-umn splice forces by 0.8R for this equivalent OCBF (R = 5) structure, resulting in an amplification factor of 4. Under this restriction, column splice forces calculated according to equiva-lent lateral force procedures would have required reinforcing of nearly every column splice in the braced frames, and rendered

Construction of the original foundation.

Erection of the steel framing.

©Alonso Nichols,Tufts University

JULY 2012 MODERN STEEL CONSTRUCTION 37

the project infeasible due to the requirements for operational continuity of the building. Furthermore, any attempt to bring the original brace members and connections into conformance with OCBF requirements also would have prevented the proj-ect from moving ahead.

Upon considering options for more advanced linear and non-linear dynamic procedures to evaluate the lateral system, an initial study was conceived to evaluate the extent to which non-linearity was expected to play a role under a site specific analysis. For this purpose, the designers applied methods similar to those described by Hines et al (see “Ground Motion Suite Selection for Eastern North America” in the March 2011 edition of ASCE Journal of Structural Engineering) to select a large and richly varying suite of over 60 relevant ground motions. Modal analyses based on these ground motions, amplified according to the site, showed elastic behavior under all ground motions in the short direction and panel zone yielding under only two ground motions in the long direction. Furthermore, initial assessments of the seismic story shears compared with story shears from wind loads implied that the effective R-factor of the braced frame was approximately 2 instead of 5. The effective R-factor is defined at the R-factor divided by the ratio of wind story shear to seismic story shear (buildings that are governed by wind loads have lower effective R-factors).

Based on this initial screening, it was determined that non-linear analyses would only add to the building assessment if they were used to construct performance limits based on incremental dynamic analyses. Since the object of the initial assessment was to demonstrate feasibility of the vertical expansion in confor-

mance with the governing code, and since the chances of elastic response to a 2% in 50-year event appeared quite high, further work was restricted to detailed modal analysis of the structure to determine the precise level of column splice reinforcement required by code. A linear dynamic approach to the problem allowed designers to take advantage of the fact that higher mode effects decreased the overturning forces on the column splices. This work resulted in identification of four locations in each frame on the first and second floors of the building where existing column splices would require reinforcement.

While reinforcement requirements for the steel frame could be minimized based on close scrutiny of existing documents, detailed analytical studies and in-situ investigations of the existing connections, missing pile layouts and details prevented answers to questions regarding the ability of the foundations to resist uplift forces due to overturning forces under wind loads. In order to address this challenge, LeMessurier developed an investiga-tion program that began with scanning all basement pile caps to determine the number of piles and their locations for each group. While the scans combined with the original column schedule and foundation layouts were able to support assessments of the pile groups under compression, missing splice details between the piles and the pile caps prevented detailed assessment of the lateral system’s tensile capacity at the foundations. This uncer-tainty and its implications were thoroughly discussed with Tufts, ARC and the peer review engineer, which resulted in a decision to specify in the construction documents the necessary tie-down reinforcement required should investigative demolition reveals insufficient pile-to-pile cap connection.

38 MODERN STEEL CONSTRUCTION JULY 2012

During construction, the investigative demolition revealed adequate splices between the piles and the pile caps, and resulted in removal of the tie-down requirements at a benefit of approxi-mately $1 million to the $68 million dollar project. This inves-tigative demolition consisted of excavating next to selected pile caps, exposing a single pile and chipping into the pile caps to find the splice reinforcement. Piles were assessed by the project’s geo-technical engineer, McPhail Associates, to have a tension capacity of 25 tons per pile, nearly twice the demand of 26 kips per pile. Selected #8 splice bars were chipped free over their entire length in the 6-ft, 6-in.-deep pile caps. These bars were assessed to yield at 47 kips, over seven times the demand of 6.6 kips per bar. In order to assess their development into the pile, individual bars were pull-tested to 19.7 kip/bar proof loads, which demonstrated a minimum safety factor of 3. Pile caps were repaired with steel friction reinforcement, epoxy grouted to the original pile cap to fully develop the pile strength.

Up from the TopIn addition to the investigation and analysis required to

verify the lateral system and minimize its reinforcement, sev-eral other measures were required to set the new steel frame on top of the existing structure. Existing columns at the roof were surveyed to be out of tolerance by as much as 2 in. While this was an acceptable tolerance for the existing building inte-rior columns, it allowed for no additional tolerance on the new columns above. LeMessurier identified this potential issue early in the design process so that the project was bid in anticipation of required corrective measures. When the final survey results were reported during construction, cap plates for the existing

columns were developed to allow new columns to be placed at their ideal grid points. LeMessurier determined the origin points of the ideal grid for the vertical expansion as the result of an optimization study that minimized the reinforcement required to resist eccentric loads on the existing columns.

Detailed analysis of existing full story transfer trusses over an auditorium in the existing structure helped to determine that no additional reinforcement would be required to support the vertical expansion. LeMessurier also advised the contractor, Shawmut Design and Construction, to account for the effects that the flexibility of these trusses would have on the proposed tower crane landing points. Ultimately, this investigation led to the placement of the tower crane in another part of the struc-ture. The height of the new structure, combined with its tight location between existing streets and buildings, presented an erection premium that motivated the designers to reduce the piece count to the greatest extent possible. To this end, most new floors were framed with beams at 15 ft on center, support-ing 16-gage deck running continuously for three spans, result-ing in a 12% piece count reduction. Floor framing was sized to exceed the vibration performance of the existing building fram-ing. This was not possible on the 14th Floor, which was subject to the vibration requirement of keeping velocities below 2,000 micro-in./sec under a range of walking regimes. This vibration criterion was met by limiting slab spans to 10 ft and increasing the stiffness of floor beams and girders as required. Reducing piece count and mitigating vibrations, along with designing the moment frames in the long direction, three monumental stairs and a perimeter screen wall at roof level, resulted in a total steel weight of 655 tons.

The expansion, which totals 105,000 sq. ft in five floors, includes clinical patient space an enlarged simulation lab and teaching facilities, conference center and offices.

©A

lons

oN

icho

ls,T

ufts

Uni

vers

ity

JULY 2012 MODERN STEEL CONSTRUCTION 39

As mentioned, a key architectural feature of the new structure was the stairway in the building’s northwest corner. This stair and its associated glass façade were designed for prominent physical and vertical integration between the new and existing structures. LeMessurier designed and detailed the stair with long spans, no intermediate hang-ers and high-vibration performance, and designed two other monumental stairs in the expansion for similar criteria. Both the northwest stair and two monumental stairs were designed for a peak acceleration limit due to walking of 0.5% g and a minimum natural frequency of 9 Hertz. Construction of the northwest stair was carefully coordi-nated so as to leave portions of the existing tenth floor open during construction. Only after the majority of steel framing had been erected was the existing northwest stair framing removed two stories down to the ninth floor, and the new HSS framed stair completed in its original place.

Since its completion in 2009, the proj-ect has fulfilled not only the needs of the school and its students, but also the neighboring community. The expanded and improved facility better positions the Dental School to increase enrollment, hire more faculty and deliver on its tradition of community service, benefiting more than 20,000 patients annually. And in an era where natural resources are scarce, it sets a standard for both environmental and urban stewardship.

The authors would like to acknowledge the team

of Robert Quigley, AIA, principal-in-charge;

Bryan Thorp, AIA, project manager; Chris-

topher Angelakis, AIA, project architect/proj-

ect designer; and Lucas Herringshaw, project

designer/interior architecture at ARC/Archi-

tectural Resources Cambridge for their dedica-

tion to making this project a success and their

contributions to this article. The authors would

also like to thank Timothy A. Nelson and Bal-

ram Chamaria, who played an important role

in the initial assessments of the facility.

OwnerTufts University, Medford, Mass.

ArchitectARC/Architectural Resources Cambridge, Cambridge, Mass.

Structural EngineerLeMessurier Consultants, Inc., Boston

General ContractorShawmut Design and Construction