The effect of the homogenizer on board of the MS Ryndam Heavy Fuel Oil (HFO) is not homogenous and has an average droplet size of 70 micron and larger. It contains numerous much larger clusters of asphaltenes and complex long-chain hydro-carbons. It is a refinery waste stream product with a high BTU content used as fuel oil. Centrifuges and automated filters are used to clean the fuel. A percentage of the purchased fuel ends up in the slop tank. HFO needs to be heated and pressurized before it can be used to operated engines or boilers. Exposing fuel to heat and pressure will unavoidably increase the size and mass of the fuel droplet, change the physical condition of the oil and negatively impact the combustion process. Implementing IPCO Power Fluid Shearing Technology reduces fuel droplet size to 3 micron and smaller to enhance the cleaning process. Smaller fuel droplets enhance combustion, lower emissions, improve fuel economy, extend engine overhaul intervals and lower overall operating costs. This report is from the evaluation of the homogenizer onboard of the MS Ryndam. The following evaluations have been performed: Baseline run Homogenizer only For this evaluation purpose the vessel is excellent. The diesel-electric propulsion will show the produced amount of KW from the engine. Because of the more engines configuration, it is possible to put one engine on load control (fixed load). Ship data Name: MS Ryndam Owner: Holland America Line Tonnage: 55,819 GT 26,118 NT 7,447 DWT Length: 220 m (720 ft) Beam: 32 m (105 ft) Draught: 7.71 m (25.3 ft) Depth: 19.13 m (62.8 ft) Year of built: 1994 Main Engine(s): 2 x Sulzer ZAV40S V12 and 3 x Sulzer ZAL40S L8 Diesel-Electric propulsion Total power: 34560 kW Traject: Lissabon - Rotterdam Evaluation: May 2012 on Engine 2 Sulzer ZAV40S V12 8640 KW Analyzing instruments: Emerson Process Management Coriolis Flow and Density Meters FuelTrax Marine Fuel Monitoring

Transcript of Ms Ryndam Homogenizer Data.Docx

Page 1: Ms Ryndam Homogenizer Data.Docx

The effect of the homogenizer on board of the MS Ryndam

Heavy Fuel Oil (HFO) is not homogenous and has an average droplet size of 70 micron and larger.

It contains numerous much larger clusters of asphaltenes and complex long-chain hydro-carbons.

It is a refinery waste stream product with a high BTU content used as fuel oil.

Centrifuges and automated filters are used to clean the fuel. A percentage of the purchased fuel ends

up in the slop tank.

HFO needs to be heated and pressurized before it can be used to operated engines or boilers.

Exposing fuel to heat and pressure will unavoidably increase the size and mass of the fuel droplet,

change the physical condition of the oil and negatively impact the combustion process.

Implementing IPCO Power Fluid Shearing Technology reduces fuel droplet size to 3 micron and

smaller to enhance the cleaning process.

Smaller fuel droplets enhance combustion, lower emissions, improve fuel economy, extend engine

overhaul intervals and lower overall operating costs.

This report is from the evaluation of the homogenizer onboard of the MS Ryndam.

The following evaluations have been performed:

Baseline run

Homogenizer only For this evaluation purpose the vessel is excellent. The diesel-electric propulsion will show the produced amount of KW from the engine. Because of the more engines configuration, it is possible to put one engine on load control (fixed load).

Ship data

Name: MS Ryndam

Owner: Holland America Line

Tonnage: 55,819 GT

26,118 NT

7,447 DWT

Length: 220 m (720 ft)

Beam: 32 m (105 ft)

Draught: 7.71 m (25.3 ft)

Depth: 19.13 m (62.8 ft)

Year of built: 1994

Main Engine(s): 2 x Sulzer ZAV40S V12 and 3 x Sulzer ZAL40S L8

Diesel-Electric propulsion Total power: 34560 kW

Traject: Lissabon - Rotterdam

Evaluation: May 2012 on Engine 2 – Sulzer ZAV40S V12 – 8640 KW

Analyzing instruments:

Emerson Process Management Coriolis Flow and Density Meters

FuelTrax Marine Fuel Monitoring

Page 2: Ms Ryndam Homogenizer Data.Docx

2

Data

Baseline

Data between 01-May-2012 17:45 and 02-May-2012 17:45

Baseline

Avg. Power: 6286,483 kW

Avg. BSFC: 212,1895 g/kWh

Homogenizer only

Data between 03-May-2012 02:00 and 03-May-2012 16:45

Homogenizer only

Avg. Power: 6275 kW

Avg. BSFC: 209,7 g/kWh

igher.

0

1000

2000

3000

4000

5000

6000

7000

8000

200

205

210

215

220

225

230

235

1-5-2012 1-5-2012 2-5-2012 2-5-2012 2-5-2012 2-5-2012 2-5-2012

BSFC

DG2_DELIVERED_POWER KW

Lineair (BSFC)

Lineair (DG2_DELIVERED_POWER KW)

0

1000

2000

3000

4000

5000

6000

7000

8000

200

205

210

215

220

225

230

235

3-5-2012 3-5-2012 3-5-2012 3-5-2012 3-5-2012 3-5-2012 3-5-2012 3-5-2012

BSFC

DG2_DELIVERED_POWER KW

Lineair (BSFC)

Lineair (DG2_DELIVERED_POWER KW)