The effect of the homogenizer on board of the MS Ryndam
Heavy Fuel Oil (HFO) is not homogenous and has an average droplet size of 70 micron and larger.
It contains numerous much larger clusters of asphaltenes and complex long-chain hydro-carbons.
It is a refinery waste stream product with a high BTU content used as fuel oil.
Centrifuges and automated filters are used to clean the fuel. A percentage of the purchased fuel ends
up in the slop tank.
HFO needs to be heated and pressurized before it can be used to operated engines or boilers.
Exposing fuel to heat and pressure will unavoidably increase the size and mass of the fuel droplet,
change the physical condition of the oil and negatively impact the combustion process.
Implementing IPCO Power Fluid Shearing Technology reduces fuel droplet size to 3 micron and
smaller to enhance the cleaning process.
Smaller fuel droplets enhance combustion, lower emissions, improve fuel economy, extend engine
overhaul intervals and lower overall operating costs.
This report is from the evaluation of the homogenizer onboard of the MS Ryndam.
The following evaluations have been performed:
Baseline run
Homogenizer only For this evaluation purpose the vessel is excellent. The diesel-electric propulsion will show the produced amount of KW from the engine. Because of the more engines configuration, it is possible to put one engine on load control (fixed load).
Ship data
Name: MS Ryndam
Owner: Holland America Line
Tonnage: 55,819 GT
26,118 NT
7,447 DWT
Length: 220 m (720 ft)
Beam: 32 m (105 ft)
Draught: 7.71 m (25.3 ft)
Depth: 19.13 m (62.8 ft)
Year of built: 1994
Main Engine(s): 2 x Sulzer ZAV40S V12 and 3 x Sulzer ZAL40S L8
Diesel-Electric propulsion Total power: 34560 kW
Traject: Lissabon - Rotterdam
Evaluation: May 2012 on Engine 2 – Sulzer ZAV40S V12 – 8640 KW
Analyzing instruments:
Emerson Process Management Coriolis Flow and Density Meters
FuelTrax Marine Fuel Monitoring
2
Data
Baseline
Data between 01-May-2012 17:45 and 02-May-2012 17:45
Baseline
Avg. Power: 6286,483 kW
Avg. BSFC: 212,1895 g/kWh
Homogenizer only
Data between 03-May-2012 02:00 and 03-May-2012 16:45
Homogenizer only
Avg. Power: 6275 kW
Avg. BSFC: 209,7 g/kWh
igher.
0
1000
2000
3000
4000
5000
6000
7000
8000
200
205
210
215
220
225
230
235
1-5-2012 1-5-2012 2-5-2012 2-5-2012 2-5-2012 2-5-2012 2-5-2012
BSFC
DG2_DELIVERED_POWER KW
Lineair (BSFC)
Lineair (DG2_DELIVERED_POWER KW)
0
1000
2000
3000
4000
5000
6000
7000
8000
200
205
210
215
220
225
230
235
3-5-2012 3-5-2012 3-5-2012 3-5-2012 3-5-2012 3-5-2012 3-5-2012 3-5-2012
BSFC
DG2_DELIVERED_POWER KW
Lineair (BSFC)
Lineair (DG2_DELIVERED_POWER KW)