Mr. Slim Air Conditioner Error Codes

download Mr. Slim Air Conditioner Error Codes

of 19

Transcript of Mr. Slim Air Conditioner Error Codes

  • 8/20/2019 Mr. Slim Air Conditioner Error Codes

    1/45

    Mr. Slim Air Conditioner Error Codes

    ttp://acerrorcode.com/mr-slim-air-conditioner-error-codes.html[03/03/2016 10:23:01 PM]

     AC Error CodeError Codes of All Air Conditioning Brands.

     

    MR. SLIM AIR CONDITIONER ERROR CODES

    December 10, 2014 Mitsubishi, Mitsubishi Electric, Mr. Slim

     

     After 

     completing

     installation and

     the wiring and

     piping of the indoor and outdoor units, check for 

     refrigerant leakage, looseness in the power supply or 

     control wiring, wrong polarity, and no disconnection

     of one phase in the supply.

    P1 Intake sensor error 

    P2 P9 Pipe (Liquid or 2-phase pipe) sensor error 

    E6 E7 Indoor/outdoor unit communication error 

    P4 Drain sensor error 

    P5  Drain pump error 

    PA Forced compressor error 

    P6  Freezing/Overheating safeguard operation

    EE  Communication error between indoor and outdoor units

    P8  Pipe temperature error 

    E4  Remote controller signal receiving error 

    Fb  Indoor unit control system error (memory error, etc.)

    E0 E3 Remote controller transmission error 

    E1 E2 Remote controller control board error 

    For details, check the LED display of the outdoor controller board.

    E9  Indoor/outdoor unit communication error (Transmitting error) (Outdoor unit)

    UP  Compressor overcurrent interruption

    U3, U4  Open/short of outdoor unit thermistors

    UF Compressor overcurrent interruption (When compressor locked)

    U2  Abnormal high discharging temperature/49C worked/insufficient refrigerant

    U1 Ud Abnormal high pressure (63H worked)/Overheating safeguard operation

    U5  Abnormal temperature of heat sink

    HOME CONTACT

    Search

    http://acerrorcode.com/http://acerrorcode.com/brands/mitsubishihttp://acerrorcode.com/brands/mitsubishi-electrichttp://acerrorcode.com/brands/mitsubishi-electrichttp://acerrorcode.com/brands/mr-slimhttp://acerrorcode.com/http://acerrorcode.com/contacthttp://acerrorcode.com/contacthttp://acerrorcode.com/http://acerrorcode.com/brands/mr-slimhttp://acerrorcode.com/brands/mitsubishi-electrichttp://acerrorcode.com/brands/mitsubishihttp://acerrorcode.com/mailto:[email protected]://plus.google.com/

  • 8/20/2019 Mr. Slim Air Conditioner Error Codes

    2/45

    Mr. Slim Air Conditioner Error Codes

    ttp://acerrorcode.com/mr-slim-air-conditioner-error-codes.html[03/03/2016 10:23:01 PM]

    U8 Outdoor unit fan safeguard stop

    U6  Compressor overcurrent interruption/Abnormal of power module

    U7 Abnormality of super heat due to low discharge temperature

    U9 UH Abnormality such as overvoltage or voltage shortage and abnormal synchronous signal to main circuit/

     Current sensor error.

    Others Other errors (Refer to the technical manual for the outdoor unit.)

    List of error codes and stop codes (for all models)

    Pdf -1

    Pdf -2

    Pdf -3

    Mr.Slim A-control error code list

    Display of remote controller 

    Code EA

    Error detail Mis-wiring of indoor/outdoor unit. exceed the number of indoor unit connection.

     Inspected unit Outdoor.

    Code Eb

     Error detail Mis-wiring of indoor/outdoor unit. (mis-wiring disconnection) Inspected unit Outdoor.

    Code EC

     Error detail Start-up time over 

     Inspected unit Outdoor.

    Code E6

     Error detail Indoor/outdoor unit transmission error (signal receiving error). Inspected unit Indoor.

    Code E7

     Error detail Indoor/outdoor unit transmission error (transmitting error).

     Inspected unit Indoor.

    Code E8

     Error detail Indoor/outdoor unit transmission error (signal receiving error).

     Inspected unit Outdoor.

    Code E9

     Error detail Indoor/outdoor unit transmission error (transmitting error).

     Inspected unit Outdoor.

    https://docs.google.com/file/d/0BwpXRGTFIK57anNjd0E2SzJvTUEhttps://docs.google.com/file/d/0BwpXRGTFIK57OEdaSGgxMWlsZzghttps://drive.google.com/file/d/0BwpXRGTFIK57RVkwbTNqX2RDc0Ehttps://drive.google.com/file/d/0BwpXRGTFIK57RVkwbTNqX2RDc0Ehttps://docs.google.com/file/d/0BwpXRGTFIK57OEdaSGgxMWlsZzghttps://docs.google.com/file/d/0BwpXRGTFIK57anNjd0E2SzJvTUE

  • 8/20/2019 Mr. Slim Air Conditioner Error Codes

    3/45

    Mr. Slim Air Conditioner Error Codes

    ttp://acerrorcode.com/mr-slim-air-conditioner-error-codes.html[03/03/2016 10:23:01 PM]

    Code E0 Error detail Remote control transmission error (signal receiving error)

     Inspected unit Remote control

    Code E3

     Error detail Remote control transmission error (transmitting error)

     Inspected unit Remote control.

    Code E4

     Error detail Remote control transmission error (signal receiving error)

     Inspected unit Indoor.

    Code E5

     Error detail Remote control transmission error (transmitting error)

     Inspected unit Indoor.

    Code EF Error detail M-NET transmission error 

     Inspected unit Indoor and outdoor.

    Code Ed

     Error detail Serial transmission error 

     Inspected unit Outdoor.

    Code P1

     Error detail Abnolmality of room temperature thermistor (TH1). Inspected unit Indoor.

    Code P2

     Error detail Abnormality of pipe temperature themistor/liquid (TH2).

     Inspected unit Indoor.

    Code P4

     Error detail Abnomarlity of drain sensor (DS)

     Inspected unit Indoor.

    Code P5

     Error detail Malfunction of drain-up machine.

     Inspected unit Indoor.

    Code P6

     Error detail Freezing/overheating protection detect.

     Inspected unit Indoor.

    Code P8

     Error detail Abnormality of pipe temperature.

     Inspected unit Indoor.

  • 8/20/2019 Mr. Slim Air Conditioner Error Codes

    4/45

    Mr. Slim Air Conditioner Error Codes

    ttp://acerrorcode.com/mr-slim-air-conditioner-error-codes.html[03/03/2016 10:23:01 PM]

    Code P9

     Error detail Anormality of pipe temperature thermistor/condenser/evaporator (TH5)

     Inspected unit Indoor.

    Code F1

     Error detail Reverse phase detection.

    Code F2

     Error detail L3 open phase detection.

    Code F3

     Error detail 63L connector open.

    Code F4

     Error detail 49C connector open.

    Code F9

     Error detail Connector 2 or more open.

    Code FA

     Error detail L2-phased open phase or 51CM connector open.

    Code F7

     Error detail Reverse phase detection circuit (p.c.board) fault.

    Code F8 Error detail Input circuit fault.

    Code U2

     Error detail Abnormal high discharging temperature.

    Code U2

     Error detail Inner thermostat (49C) operation.

    Code U1 Error detail Abnormal high pressure (high pressure swicth 63H worked)

    Code U1

     Error detail Direct cut operation.

    Code UE

     Error detail High pressure error (ball valve closed)

    Code UL Error detail Abnormal low pressure.

    Code Ud

     Error detail Over heat protection

  • 8/20/2019 Mr. Slim Air Conditioner Error Codes

    5/45

    Mr. Slim Air Conditioner Error Codes

    ttp://acerrorcode.com/mr-slim-air-conditioner-error-codes.html[03/03/2016 10:23:01 PM]

    Code U6

     Error detail Compressor over current (overload) cut off.

    Code UA

     Error detail Compressor over current (terminal relay operation).

    Code UF Error detail Compressor over current (start-up locked) cut off.

    Code UF

     Error detail Compressor over current (operating locked) cut off.

    Code UH

     Error detail Current sensor error.

    Code U3 Error detail Discharge thermistor short/open.

    Code U4

     Error detail Outdoor thermistor short/open.

    Mr.Slim K-control

     Display of remote controller 

    LED E0 Diagnosis of malfunction Transmitting/receiving signal error.

     Inspected unit Indoor.

    LED P1

     Diagnosis of malfunction Intake air sensor abnormal.

     Inspected unit Indoor.

    LED P2

     Diagnosis of malfunction Pipe sensor abnormal.

     Inspected unit Indoor.

    LED P4

     Diagnosis of malfunction Drain sensor abnormal.

     Inspected unit Indoor.

    LED P5

     Diagnosis of malfunction Malfunctioning of the drain overflow protecting mechanism.

     Inspected unit Indoor.

    LED P6

     Diagnosis of malfunction Abnomality of the coil frost/overheating protection mode.

     Inspected unit Indoor.

  • 8/20/2019 Mr. Slim Air Conditioner Error Codes

    6/45

    Mr. Slim Air Conditioner Error Codes

    ttp://acerrorcode.com/mr-slim-air-conditioner-error-codes.html[03/03/2016 10:23:01 PM]

    LED P3

     Diagnosis of malfunction System error (transmitting/receiving signal).

     Inspected unit Indoor.

    LED P7

     Diagnosis of malfunction System error (address)

     Inspected unit Indoor.

    LED P8

     Diagnosis of malfunction Outdoor unit malfunction

     Inspected unit Outdoor.

    Mr.Slim K-control PUH-EK

     Outdoor unit

    LED ON = Operation status

     LED Flash = Check code diplay

    LED LD1

     LED ON Compressor directive

     LED Flash Reverse phase detect

    LED LD2

     LED ON Heating directive

     LED Flash Open phase detect

    LED LD3

     LED ON During 63H1 operation

     LED Flash Pipe sensor short/open

    LED LD4

     LED ON Compressor ON

     LED Flash High pressure swicth (63H2) operation.

    LED LD5

     LED ON Outdoor fan ON

     LED Flash Over current relay (51CM) operation.

    LED LD6

     LED ON 4-way valve ON

     LED Flash Thermal swicth (26C) operation.

    LED LD7

     LED ON Bypass valve ON

     LED Flash Thermistor (TH3) overheat protection.

    LED LD8

     LED ON Crankcase heater ON

  • 8/20/2019 Mr. Slim Air Conditioner Error Codes

    7/45

    Mr. Slim Air Conditioner Error Codes

    ttp://acerrorcode.com/mr-slim-air-conditioner-error-codes.html[03/03/2016 10:23:01 PM]

     LED Flash Devective input.

    Mitsubishi Electric ‘Mr. Slim’ P-Series Commercial Models

      Mitsubishi Electric ‘Mr. Slim’ P-Series Commercial Models

    TROUBLESHOOTING TIPS / P8 ERROR CODE

    List of error codes and stop codes (for all models)

    Pdf -1

    Pdf -2

    Pdf -3

     

    Mitsubishi Mr.Slim Error Code Pdf 

    Mr Slim MULTI-S CHECK CODE

    https://docs.google.com/file/d/0BwpXRGTFIK57VjYtN1hsQm9KMjA/previewhttps://docs.google.com/file/d/0BwpXRGTFIK57anNjd0E2SzJvTUEhttps://docs.google.com/file/d/0BwpXRGTFIK57OEdaSGgxMWlsZzghttps://drive.google.com/file/d/0BwpXRGTFIK57RVkwbTNqX2RDc0Ehttps://docs.google.com/file/d/0BwpXRGTFIK57X1BMVk91ZmFWMFk/previewhttps://docs.google.com/file/d/0BwpXRGTFIK57X1BMVk91ZmFWMFk/previewhttps://drive.google.com/file/d/0BwpXRGTFIK57RVkwbTNqX2RDc0Ehttps://docs.google.com/file/d/0BwpXRGTFIK57OEdaSGgxMWlsZzghttps://docs.google.com/file/d/0BwpXRGTFIK57anNjd0E2SzJvTUEhttps://docs.google.com/file/d/0BwpXRGTFIK57VjYtN1hsQm9KMjA/preview

  • 8/20/2019 Mr. Slim Air Conditioner Error Codes

    8/45

    Mr. Slim Air Conditioner Error Codes

    ttp://acerrorcode.com/mr-slim-air-conditioner-error-codes.html[03/03/2016 10:23:01 PM]

     ERROR CODE = 1102

    POSTPONED ERROR CODE = 1202

    FAULT = Discharge temperature is unusual

    DETECTED UNIT

    Indoor Unit =

    Outdoor Unit = *

    Remote Control =

    THE PART TO BE CHECKED

    1) Confirm whether gas leak or gas shortage occurred

    2) Is the ball valve open?

    ERROR CODE = 1108

    POSTPONED ERROR CODE = 1208

    FAULT = Inner thermostat of compressor is unusual

    DETECTED UNIT

    Indoor Unit =

    Outdoor Unit = *

    Remote Control =

    THE PART TO BE CHECKED

    1) Confirm whether gas leak or gas shortage occurred

    2) Is the S phase on outdoor board open?

    ERROR CODE = 1302

    POSTPONED ERROR CODE = 1402

    FAULT = High-pressure is unusual

    DETECTED UNIT

  • 8/20/2019 Mr. Slim Air Conditioner Error Codes

    9/45

    Mr. Slim Air Conditioner Error Codes

    ttp://acerrorcode.com/mr-slim-air-conditioner-error-codes.html[03/03/2016 10:23:01 PM]

    Indoor Unit =

    Outdoor Unit = *

    Remote Control =

    THE PART TO BE CHECKED

    1) Is the ball valve opened?

    2) Confirm whether indoor filter is blocked or whether outdoor short cycle occurred

    ERROR CODE = 1500

    POSTPONED ERROR CODE = 1600

    FAULT = Refrigerant is overcharged

    DETECTED UNIT

    Indoor Unit =

    Outdoor Unit = *

    Remote Control =

    THE PART TO BE CHECKED

    1) Confirm whether gas leak or gas shortage occurred

    2) Is the ball valve open?

    ERROR CODE = 1501

    POSTPONED ERROR CODE = 1601

    FAULT = Refrigerant is insufficient

    DETECTED UNIT

    Indoor Unit =

    Outdoor Unit = *

    Remote Control =

    THE PART TO BE CHECKED

  • 8/20/2019 Mr. Slim Air Conditioner Error Codes

    10/45

    Mr. Slim Air Conditioner Error Codes

    ttp://acerrorcode.com/mr-slim-air-conditioner-error-codes.html[03/03/2016 10:23:01 PM]

    1) Confirm whether gas leak or gas shortage occurred

    2) Is the ball valve open?

    ERROR CODE = 1505

    POSTPONED ERROR CODE = 1605

    FAULT = Vacuum operation is protected

    DETECTED UNIT

    Indoor Unit =

    Outdoor Unit = *

    Remote Control =

    THE PART TO BE CHECKED

    1) Confirm whether gas leak or gas shortage occurred

    2) Is the ball valve open?

    ERROR CODE = 2502

    POSTPONED ERROR CODE =

    FAULT = Drain pump is unusual

    DETECTED UNIT

    Indoor Unit = *

    Outdoor Unit =

    Remote Control =

    THE PART TO BE CHECKED

    1) Confirm whether drain pipe is inclined or blocked

    2) Connector of drain pipe seperated

    ERROR CODE = 2503

    POSTPONED ERROR CODE =

  • 8/20/2019 Mr. Slim Air Conditioner Error Codes

    11/45

    Mr. Slim Air Conditioner Error Codes

    ttp://acerrorcode.com/mr-slim-air-conditioner-error-codes.html[03/03/2016 10:23:01 PM]

    FAULT = Drain sensor (THd) is unusual

    DETECTED UNIT

    Indoor Unit = *

    Outdoor Unit =

    Remote Control =

    THE PART TO BE CHECKED

    1) Drain sensor is dirty

    2) CN50 connector on indoor board seperated

    ERROR CODE = 4115

    POSTPONED ERROR CODE = 4165

    FAULT = Synchronizing signal of power is unusual

    DETECTED UNIT

    Indoor Unit =

    Outdoor Unit = *

    Remote Control =

    THE PART TO BE CHECKED

    1) Is R phase or T phase open?

    2) Has fuse of R phase or T phase blown?

    ERROR CODE = 4116

    POSTPONED ERROR CODE =

    FAULT = Rotation amount of fan is wrong (PKFY-AM)

    DETECTED UNIT

    Indoor Unit = *

    Outdoor Unit =

  • 8/20/2019 Mr. Slim Air Conditioner Error Codes

    12/45

    Mr. Slim Air Conditioner Error Codes

    ttp://acerrorcode.com/mr-slim-air-conditioner-error-codes.html[03/03/2016 10:23:01 PM]

    Remote Control =

    THE PART TO BE CHECKED

    1) Is air filter blocked

    ERROR CODE = 4220

    POSTPONED ERROR CODE = 4320

    FAULT = Voltage of inverter bus is insufficient

    DETECTED UNIT

    Indoor Unit =

    Outdoor Unit = *

    Remote Control =

    THE PART TO BE CHECKED

    1) Is S phase open?

    ERROR CODE = 4230

    POSTPONED ERROR CODE = 4330

    FAULT = Temperature of heat dissipation board is unusual

    DETECTED UNIT

    Indoor Unit =

    Outdoor Unit = *

    Remote Control =

    THE PART TO BE CHECKED

    1) Is ventilation of heat dissipation board for cooling blocked

    ERROR CODE = 4250

    POSTPONED ERROR CODE = 4350

    FAULT = IPM error (Heat current is intercepted) IPM error 

  • 8/20/2019 Mr. Slim Air Conditioner Error Codes

    13/45

    Mr. Slim Air Conditioner Error Codes

    ttp://acerrorcode.com/mr-slim-air-conditioner-error-codes.html[03/03/2016 10:23:01 PM]

    DETECTED UNIT

    Indoor Unit =

    Outdoor Unit = *

    Remote Control =

    THE PART TO BE CHECKED

    1) Is any power phase open?

    2) Has voltage of power supply failed?

    ERROR CODE = 5101

    POSTPONED ERROR CODE = 1202

    FAULT = Thermistor (TH21) for suction temperature is unusual

    DETECTED UNIT

    Indoor Unit = *

    Outdoor Unit =

    Remote Control =

    THE PART TO BE CHECKED = 1) CN20 connector on indoor board seperated

    ERROR CODE = 5101

    POSTPONED ERROR CODE = 1202

    FAULT = Thermistor (TH1) for Discharge temperature is unusual

    DETECTED UNIT

    Indoor Unit =

    Outdoor Unit = *

    Remote Control =

    THE PART TO BE CHECKED = 1) TH1 connector on outdoor board seperated

    ERROR CODE = 5102

  • 8/20/2019 Mr. Slim Air Conditioner Error Codes

    14/45

    Mr. Slim Air Conditioner Error Codes

    ttp://acerrorcode.com/mr-slim-air-conditioner-error-codes.html[03/03/2016 10:23:01 PM]

    POSTPONED ERROR CODE = 1211

    FAULT = Thermistor (TH22) for refrigerant pipe temperature is unusual

    DETECTED UNIT

    Indoor Unit = *

    Outdoor Unit =

    Remote Control =

    THE PART TO BE CHECKED = 1) CN21 connector on indoor board seperated

    ERROR CODE = 5102

    POSTPONED ERROR CODE = 1211

    FAULT = Thermistor (TH2) for suction pressure saturation temperature is unusual

    DETECTED UNIT

    Indoor Unit =

    Outdoor Unit = *

    Remote Control =

    THE PART TO BE CHECKED = 1) TH2 connector on outdoor board seperated

    ERROR CODE = 5103

    POSTPONED ERROR CODE = 1213

    FAULT = Thermistor (TH23) for gas pipe temperature is unusual

    DETECTED UNIT

    Indoor Unit = *

    Outdoor Unit =

    Remote Control =

    THE PART TO BE CHECKED = 1) TH29 connector on indoor board seperated

    ERROR CODE = 5105

  • 8/20/2019 Mr. Slim Air Conditioner Error Codes

    15/45

    Mr. Slim Air Conditioner Error Codes

    ttp://acerrorcode.com/mr-slim-air-conditioner-error-codes.html[03/03/2016 10:23:01 PM]

    POSTPONED ERROR CODE = 1205

    FAULT = Thermistor (TH5) for condensor outlet temperature is unusual

    DETECTED UNIT

    Indoor Unit =

    Outdoor Unit = *

    Remote Control =

    THE PART TO BE CHECKED = 1) TH5 connector on indoor board seperated

    ERROR CODE = 5106

    POSTPONED ERROR CODE = 1221

    FAULT = Thermistor (TH6) for outdoor temperature is unusual

    DETECTED UNIT

    Indoor Unit =

    Outdoor Unit = *

    Remote Control =

    THE PART TO BE CHECKED = 1) TH6 connector on indoor board seperated

    ERROR CODE = 5110

    POSTPONED ERROR CODE = 1214

    FAULT = Thermistor (THHS) for IPM heat dissipation board temperature is unusual

    DETECTED UNIT

    Indoor Unit =

    Outdoor Unit = *

    Remote Control =

    THE PART TO BE CHECKED = 1) THHS connector on indoor board seperated

    ERROR CODE = 5201

  • 8/20/2019 Mr. Slim Air Conditioner Error Codes

    16/45

    Mr. Slim Air Conditioner Error Codes

    ttp://acerrorcode.com/mr-slim-air-conditioner-error-codes.html[03/03/2016 10:23:01 PM]

    POSTPONED ERROR CODE = 1402

    FAULT = Pressure sensor (63HS) is unusual

    DETECTED UNIT

    Indoor Unit =

    Outdoor Unit = *

    Remote Control =

    THE PART TO BE CHECKED = 1) Affirm whether gas leak or gas shortage occurred

    ERROR CODE = 6600

    POSTPONED ERROR CODE =

    FAULT = Address double definition error 

    DETECTED UNIT

    Indoor Unit = *

    Outdoor Unit = *

    Remote Control = *

    THE PART TO BE CHECKED = 1) Is the same address as the error generating origin specified?

    ERROR CODE = 6602

    POSTPONED ERROR CODE =

    FAULT = Transmission processor H/W error 

    DETECTED UNIT

    Indoor Unit = *

    Outdoor Unit = *

    Remote Control = *

    THE PART TO BE CHECKED = 1) Turn power OFF simultaneously for 2 minutes or more, Then turn them back on

     again.

    ERROR CODE = 6603

  • 8/20/2019 Mr. Slim Air Conditioner Error Codes

    17/45

    Mr. Slim Air Conditioner Error Codes

    ttp://acerrorcode.com/mr-slim-air-conditioner-error-codes.html[03/03/2016 10:23:01 PM]

    POSTPONED ERROR CODE =

    FAULT = Transmission circuit (bus) Busy error 

    DETECTED UNIT

    Indoor Unit = *

    Outdoor Unit = *

    Remote Control = *

    THE PART TO BE CHECKED = 1) Wiring mistake of TB3 or TB7 on outdoor unit

    ERROR CODE = 6606

    POSTPONED ERROR CODE =

    FAULT = Communication error with the transmission processor 

    DETECTED UNIT

    Indoor Unit = *

    Outdoor Unit = *

    Remote Control = *

    THE PART TO BE CHECKED = 1) Turn power OFF simultaneously for 2 minutes or more, Then turn them back on

     again.

    ERROR CODE = 6607

    POSTPONED ERROR CODE =

    FAULT = No ACK

    DETECTED UNIT

    Indoor Unit = *

    Outdoor Unit =

    Remote Control = *

    THE PART TO BE CHECKED = 1) Address setting is improper, or transmission cable seperated

  • 8/20/2019 Mr. Slim Air Conditioner Error Codes

    18/45

    Mr. Slim Air Conditioner Error Codes

    ttp://acerrorcode.com/mr-slim-air-conditioner-error-codes.html[03/03/2016 10:23:01 PM]

    ERROR CODE =6608

    POSTPONED ERROR CODE =

    FAULT = No response

    DETECTED UNIT

    Indoor Unit = *

    Outdoor Unit =

    Remote Control = *

    THE PART TO BE CHECKED = 1) Check the used electric wire

    ERROR CODE = 6810

    POSTPONED ERROR CODE =

    FAULT = UR communicaton

    DETECTED UNIT

    Indoor Unit = *

    Outdoor Unit =

    Remote Control = *

    THE PART TO BE CHECKED = 1) Wire connection for the unit remote control transmission is poor 

    ERROR CODE = 7100

    POSTPONED ERROR CODE =

    FAULT = Over index

    DETECTED UNIT

    Indoor Unit =

    Outdoor Unit = *

    Remote Control =

    THE PART TO BE CHECKED = 1) Has index been exceeded

  • 8/20/2019 Mr. Slim Air Conditioner Error Codes

    19/45

    Mr. Slim Air Conditioner Error Codes

    ttp://acerrorcode.com/mr-slim-air-conditioner-error-codes.html[03/03/2016 10:23:01 PM]

    ERROR CODE = 7101

    POSTPONED ERROR CODE =

    FAULT = Over index

    DETECTED UNIT

    Indoor Unit = *

    Outdoor Unit = *

    Remote Control =

    THE PART TO BE CHECKED = 1) Has an indoor unit beyond the permitted index connected

    ERROR CODE = 7102

    POSTPONED ERROR CODE =

    FAULT = The number of connected units

    DETECTED UNIT

    Indoor Unit =

    Outdoor Unit = *

    Remote Control =

    THE PART TO BE CHECKED

    1) Are connected units over the number of restriction?

    2) Transmission cord of indoor unit seperated

    ERROR CODE = 7105

    POSTPONED ERROR CODE =

    FAULT = Address setting error 

    DETECTED UNIT

    Indoor Unit =

    Outdoor Unit = *

  • 8/20/2019 Mr. Slim Air Conditioner Error Codes

    20/45

    Mr. Slim Air Conditioner Error Codes

    ttp://acerrorcode.com/mr-slim-air-conditioner-error-codes.html[03/03/2016 10:23:01 PM]

    Remote Control =

    THE PART TO BE CHECKED = 1) Is outdoor unit address set to 000 or to a range of 51-100?

    ERROR CODE = 7111

    POSTPONED ERROR CODE =

    FAULT = Remote control sensor is unusual

    DETECTED UNIT

    Indoor Unit = *

    Outdoor Unit =

    Remote Control =

    Mr Slim A-CONTROL CHECK CODE (U INDICATIONS)

     

    INDICATIONS ON REMOTE CONTROL = U1

    INDICATIONS ON OUTDOOR UNIT

    LED1 (GREEN) =

    LED2 (RED) =

    FAULTS = Unusual high pressure (63H) operated

    STANDARD =

    INVERTER = *

    DETECTED UNIT = Outdoor Unit

    THE PART TO BE CHECKED = 1) Is ball valve open?

    2) Check the indoor/outdoor short cycle

     

    INDICATIONS ON REMOTE CONTROL = U2

  • 8/20/2019 Mr. Slim Air Conditioner Error Codes

    21/45

    Mr. Slim Air Conditioner Error Codes

    ttp://acerrorcode.com/mr-slim-air-conditioner-error-codes.html[03/03/2016 10:23:01 PM]

    INDICATIONS ON OUTDOOR UNIT

    LED1 (GREEN) = Flash 3 Times

    LED2 (RED) = Flash Once

    FAULTS = Discharge temperature is unusual/49C (inner thermostat operated) Refrigerant is insufficient

    STANDARD =

    INVERTER = *

    DETECTED UNIT = Outdoor Unit

    THE PART TO BE CHECKED = 1) Check whether air filter is dirty to Clean it

    2) Confirm whether gas leak or gas shortage occurred

    3) Check the indoor/outdoor short cycle

     

    INDICATIONS ON REMOTE CONTROL = U7

    INDICATIONS ON OUTDOOR UNIT

    LED1 (GREEN) = Flash 3 Times

    LED2 (RED) = Flash Once

    FAULTS = Superheat occurred by low discharge

    STANDARD =

    INVERTER = *

    DETECTED UNIT = Outdoor Unit

    THE PART TO BE CHECKED = 1) Has the discharge thermistor seperated?

    2) Confirm whether electronic expansion valve has failed

    3) Check CN LEV connector on the outdoor board

     

    INDICATIONS ON REMOTE CONTROL = UE

  • 8/20/2019 Mr. Slim Air Conditioner Error Codes

    22/45

    Mr. Slim Air Conditioner Error Codes

    ttp://acerrorcode.com/mr-slim-air-conditioner-error-codes.html[03/03/2016 10:23:01 PM]

    INDICATIONS ON OUTDOOR UNIT

    LED1 (GREEN) = Flash 3 Times

    LED2 (RED) = Flash Twice

    FAULTS = Unusual high-pressure (63H) operated

    STANDARD = *

    INVERTER = *

    DETECTED UNIT = Outdoor Unit

    THE PART TO BE CHECKED = 1) Is the ball valve open?

    2) Check the indoor/outdoor short cycle

    3) Is gas overcharged

     

    INDICATIONS ON REMOTE CONTROL = UL

    INDICATIONS ON OUTDOOR UNIT

    LED1 (GREEN) = Flash 3 Times

    LED2 (RED) = Flash Twice

    FAULTS = Unusual low-pressure (63L) operated

    STANDARD = *

    INVERTER =

    DETECTED UNIT = Outdoor Unit

    THE PART TO BE CHECKED = 1) Is the ball valve open?

    2) Confirm whether gas leak or gas shortage has occurred

     

    INDICATIONS ON REMOTE CONTROL = Ud

    INDICATIONS ON OUTDOOR UNIT

  • 8/20/2019 Mr. Slim Air Conditioner Error Codes

    23/45

    Mr. Slim Air Conditioner Error Codes

    ttp://acerrorcode.com/mr-slim-air-conditioner-error-codes.html[03/03/2016 10:23:01 PM]

    LED1 (GREEN) = Flash 3 Times

    LED2 (RED) = Flash 3 Times

    FAULTS = Over raise is protected (overload operation is protected/Fan fault)

    STANDARD = *

    INVERTER =

    DETECTED UNIT = Outdoor Unit

    THE PART TO BE CHECKED = 1) Check whether outdoor heat exchanger is dirty try to Clean it

    2) Check the outdoor short cycle

     

    INDICATIONS ON REMOTE CONTROL = U6

    INDICATIONS ON OUTDOOR UNIT

    LED1 (GREEN) = Flash 3 Times

    LED2 (RED) = Flash 4 Times

    FAULTS = Compressor is intercepted by over-current (overload)

    STANDARD = *

    INVERTER = *

    DETECTED UNIT = Outdoor Unit

    THE PART TO BE CHECKED = 1) After turning crank case heater on, have 12 hours or more passed?

     

    INDICATIONS ON REMOTE CONTROL = U6

    INDICATIONS ON OUTDOOR UNIT

    LED1 (GREEN) = Flash 3 Times

    LED2 (RED) = Flash 4 Times

    FAULTS = Powered module fault occurred

  • 8/20/2019 Mr. Slim Air Conditioner Error Codes

    24/45

    Mr. Slim Air Conditioner Error Codes

    ttp://acerrorcode.com/mr-slim-air-conditioner-error-codes.html[03/03/2016 10:23:01 PM]

    STANDARD =

    INVERTER = *

    DETECTED UNIT = Outdoor Unit

    THE PART TO BE CHECKED = (Replace the outdoor board)

     

    INDICATIONS ON REMOTE CONTROL = UC

    INDICATIONS ON OUTDOOR UNIT

    LED1 (GREEN) = Flash 3 Times

    LED2 (RED) = Flash 4 Times

    FAULTS = Compressor self protection activated

    STANDARD = *

    INVERTER = *

    DETECTED UNIT = Outdoor Unit

    THE PART TO BE CHECKED = 1) Is ball valve open?

     

    INDICATIONS ON REMOTE CONTROL = UF

    INDICATIONS ON OUTDOOR UNIT

    LED1 (GREEN) = Flash 3 Times

    LED2 (RED) = Flash 4 Times

    FAULTS = Compressor is over-current (locked)

    STANDARD = *

    INVERTER = *

    DETECTED UNIT = Outdoor Unit

    THE PART TO BE CHECKED = 1) Is ball valve open?

  • 8/20/2019 Mr. Slim Air Conditioner Error Codes

    25/45

    Mr. Slim Air Conditioner Error Codes

    ttp://acerrorcode.com/mr-slim-air-conditioner-error-codes.html[03/03/2016 10:23:01 PM]

    2) Is power capacity insufficient?

     

    INDICATIONS ON REMOTE CONTROL = UH

    INDICATIONS ON OUTDOOR UNIT

    LED1 (GREEN) = Flash 3 Times

    LED2 (RED) = Flash 4 Times

    FAULTS = Current sensor is unusual

    STANDARD = *

    INVERTER = *

    DETECTED UNIT = Outdoor Unit

    THE PART TO BE CHECKED = 1) If outdoor board has been replaced: Check wiring and board setting

     

    INDICATIONS ON REMOTE CONTROL = U3

    INDICATIONS ON OUTDOOR UNIT

    LED1 (GREEN) = Flash 3 Times

    LED2 (RED) = Flash 5 Times

    FAULTS = Discharge thermistor (TH14) is open/short

    STANDARD = *

    INVERTER = *

    DETECTED UNIT = Outdoor Unit

    THE PART TO BE CHECKED = TH4 connector on outdoor board seperated

     

    INDICATIONS ON REMOTE CONTROL = U4

    INDICATIONS ON OUTDOOR UNIT

  • 8/20/2019 Mr. Slim Air Conditioner Error Codes

    26/45

    Mr. Slim Air Conditioner Error Codes

    ttp://acerrorcode.com/mr-slim-air-conditioner-error-codes.html[03/03/2016 10:23:01 PM]

    LED1 (GREEN) = Flash 3 Times

    LED2 (RED) = Flash 5 Times

    FAULTS = Pipe thermistor (TH3) is open/short

    STANDARD = *

    INVERTER = *

    DETECTED UNIT = Outdoor Unit

    THE PART TO BE CHECKED = TH3 connector on outdoor board seperated

     

    INDICATIONS ON REMOTE CONTROL = U4

    INDICATIONS ON OUTDOOR UNIT

    LED1 (GREEN) = Flash 3 Times

    LED2 (RED) = Flash 5 Times

    FAULTS = 2-phase pipe thermistor (TH6) is open/short

    STANDARD =

    INVERTER = *

    DETECTED UNIT = Outdoor Unit

    THE PART TO BE CHECKED = TH6 connector on outdoor board seperated

     

    INDICATIONS ON REMOTE CONTROL = U4

    INDICATIONS ON OUTDOOR UNIT

    LED1 (GREEN) = Flash 3 Times

    LED2 (RED) = Flash 5 Times

    FAULTS = Outdoor temperature thermistor (TH7) is open/short

    STANDARD =

  • 8/20/2019 Mr. Slim Air Conditioner Error Codes

    27/45

  • 8/20/2019 Mr. Slim Air Conditioner Error Codes

    28/45

    Mr. Slim Air Conditioner Error Codes

    ttp://acerrorcode.com/mr-slim-air-conditioner-error-codes.html[03/03/2016 10:23:01 PM]

    INDICATIONS ON REMOTE CONTROL = UP

    INDICATIONS ON OUTDOOR UNIT

    LED1 (GREEN) =

    LED2 (RED) =

    FAULTS = Compressor is intercepted by over-current

    STANDARD =

    INVERTER = *

    DETECTED UNIT = Outdoor Unit

    THE PART TO BE CHECKED = 1) Is ball valve open? 

    Mr Slim A-CONTROL CHECK CODE (F.P INDICATIONS)

     

    INDICATIONS ON REMOTE CONTROL = F1

    INDICATIONS ON OUTDOOR UNIT

    LED1 (GREEN) = Flash Once

    LED2 (RED) = Flash Once

    FAULTS = Negative phase is detected, or power or connection between indoor unit and outdoor unit is incorrec

    STANDARD = *

    INVERTER =

    DETECTED UNIT = Outdoor Unit

    THE PART TO BE CHECKED = 1) Power or connection cable between indoor unit and outdoor unit is misplaced

    2) Negative Phase –> Exchange R.T phase on outdoor power terminal

  • 8/20/2019 Mr. Slim Air Conditioner Error Codes

    29/45

    Mr. Slim Air Conditioner Error Codes

    ttp://acerrorcode.com/mr-slim-air-conditioner-error-codes.html[03/03/2016 10:23:01 PM]

    3) Are all the 3 phases of power voltage the same voltage

     

    INDICATIONS ON REMOTE CONTROL = F2

    INDICATIONS ON OUTDOOR UNIT

    LED1 (GREEN) = Flash Once

    LED2 (RED) = Flash Once

    FAULTS = Open phase is detected (T phase is open)

    STANDARD = *

    INVERTER =

    DETECTED UNIT = Outdoor Unit

    THE PART TO BE CHECKED = 1) T phase of outdoor power terminal is loose

    2) Are all the 3 phases of power voltage the same voltage

     

    INDICATIONS ON REMOTE CONTROL = F3

    INDICATIONS ON OUTDOOR UNIT

    LED1 (GREEN) = Flash Once

    LED2 (RED) = Flash Twice

    FAULTS = Connector (63H) is open

    STANDARD = *

    INVERTER = *

    DETECTED UNIT = Outdoor Unit

    THE PART TO BE CHECKED = 1) Connector (63L) on outdoor board seperated

    2) Terminal of low-pressure switch (63L) seperated

     

  • 8/20/2019 Mr. Slim Air Conditioner Error Codes

    30/45

    Mr. Slim Air Conditioner Error Codes

    ttp://acerrorcode.com/mr-slim-air-conditioner-error-codes.html[03/03/2016 10:23:01 PM]

    INDICATIONS ON REMOTE CONTROL = F5

    INDICATIONS ON OUTDOOR UNIT

    LED1 (GREEN) = Flash Once

    LED2 (RED) = Flash Twice

    FAULTS = Connector (63H) is open

    STANDARD = *

    INVERTER = *

    DETECTED UNIT = Outdoor Unit

    THE PART TO BE CHECKED = 1) Connector (63H) on outdoor board seperated

    2) Terminal of high-pressure switch (63H) seperated

     

    INDICATIONS ON REMOTE CONTROL = F9

    INDICATIONS ON OUTDOOR UNIT

    LED1 (GREEN) = Flash Once

    LED2 (RED) = Flash Twice

    FAULTS = Two or more connectors are open

    STANDARD = *

    INVERTER = *

    DETECTED UNIT = Outdoor Unit

    THE PART TO BE CHECKED = 1) Confirm whether the connector on board seperated, or is loose

     

    INDICATIONS ON REMOTE CONTROL = F7

    INDICATIONS ON OUTDOOR UNIT

    LED1 (GREEN) = Flash Once

  • 8/20/2019 Mr. Slim Air Conditioner Error Codes

    31/45

    Mr. Slim Air Conditioner Error Codes

    ttp://acerrorcode.com/mr-slim-air-conditioner-error-codes.html[03/03/2016 10:23:01 PM]

    LED2 (RED) = Flash 3 times

    FAULTS = Circuit (board) of negative phase detection is poor 

    STANDARD = *

    INVERTER =

    DETECTED UNIT = Outdoor Unit

    THE PART TO BE CHECKED = (Replace the outdoor board)

     

    INDICATIONS ON REMOTE CONTROL = F8

    INDICATIONS ON OUTDOOR UNIT

    LED1 (GREEN) = Flash Once

    LED2 (RED) = Flash 3 times

    FAULTS = Input circuit (board) is poor 

    STANDARD = *

    INVERTER = *

    DETECTED UNIT = Outdoor Unit

    THE PART TO BE CHECKED = (Replace the outdoor board)

     

    INDICATIONS ON REMOTE CONTROL = P1

    INDICATIONS ON OUTDOOR UNIT

    LED1 (GREEN) = Flash 4 Times

    LED2 (RED) = Flash Once

    FAULTS = Suction sensor is unusual

    STANDARD = *

    INVERTER = *

  • 8/20/2019 Mr. Slim Air Conditioner Error Codes

    32/45

    Mr. Slim Air Conditioner Error Codes

    ttp://acerrorcode.com/mr-slim-air-conditioner-error-codes.html[03/03/2016 10:23:01 PM]

    DETECTED UNIT = Indoor Unit

    THE PART TO BE CHECKED = 1) CN20 connector on indoor board seperated

     

    INDICATIONS ON REMOTE CONTROL = P2

    INDICATIONS ON OUTDOOR UNIT

    LED1 (GREEN) = Flash 4 Times

    LED2 (RED) = Flash Once

    FAULTS = pipe (refrigerant pipe) sensor is unusual

    STANDARD = *

    INVERTER = *

    DETECTED UNIT = Indoor Unit

    THE PART TO BE CHECKED = 1) CN21 connector on indoor board seperated

     

    INDICATIONS ON REMOTE CONTROL = P4

    INDICATIONS ON OUTDOOR UNIT

    LED1 (GREEN) = Flash 4 Times

    LED2 (RED) = Flash Twice

    FAULTS = Drain sensor is unusual

    STANDARD = *

    INVERTER = *

    DETECTED UNIT = Indoor Unit

    THE PART TO BE CHECKED = 1) CN31 connector on indoor board seperated

     

    INDICATIONS ON REMOTE CONTROL = P5

  • 8/20/2019 Mr. Slim Air Conditioner Error Codes

    33/45

    Mr. Slim Air Conditioner Error Codes

    ttp://acerrorcode.com/mr-slim-air-conditioner-error-codes.html[03/03/2016 10:23:01 PM]

    INDICATIONS ON OUTDOOR UNIT

    LED1 (GREEN) = Flash 4 Times

    LED2 (RED) = Flash Twice

    FAULTS = Drain overflow is protected or water leakage ocurred

    STANDARD = *

    INVERTER = *

    DETECTED UNIT = Indoor Unit

    THE PART TO BE CHECKED = 1) Confirm whether draining pipe is inclined or blocked

    2) Confirm whether drain-pan or drain sensor becomes dirty

    3) CNP connector on indoor board seperated

     

    INDICATIONS ON REMOTE CONTROL = P6

    INDICATIONS ON OUTDOOR UNIT

    LED1 (GREEN) = Flash 4 Times

    LED2 (RED) = Flash 3 Times

    FAULTS = Freeze protecting (in cooling mode) / Over rise protecting (in heating mode)

    STANDARD = *

    INVERTER = *

    DETECTED UNIT = Indoor Unit

    THE PART TO BE CHECKED = 1) Air filter is dirty

    2) Gas leak or gas shortage occurred

    3) Does fan work on indoor unit?

     – Check the fan connector 

     

  • 8/20/2019 Mr. Slim Air Conditioner Error Codes

    34/45

    Mr. Slim Air Conditioner Error Codes

    ttp://acerrorcode.com/mr-slim-air-conditioner-error-codes.html[03/03/2016 10:23:01 PM]

    INDICATIONS ON REMOTE CONTROL = P8

    INDICATIONS ON OUTDOOR UNIT

    LED1 (GREEN) = Flash 4 Times

    LED2 (RED) = Flash 4 Times

    FAULTS = Pipe temperature is unusual

    STANDARD = *

    INVERTER = *

    DETECTED UNIT = Indoor Unit

    THE PART TO BE CHECKED = 1) Confirm whether wiring between indoor unit and outdoor unit or piping is faulty

     when using 2 indoor units

    2) Gas leak or gas shortage occurred

     

    INDICATIONS ON REMOTE CONTROL = P9

    INDICATIONS ON OUTDOOR UNIT

    LED1 (GREEN) =

    LED2 (RED) =

    FAULTS = Pipe (two-phase pipe) sensor is unusual

    STANDARD =

    INVERTER = *

    DETECTED UNIT = Indoor Unit

    THE PART TO BE CHECKED = 1) CN29 connector on indoor board seperated

    Mr Slim A-Control Check Code (E Indication)

     

    INDICATIONS ON REMOTE CONTROL = E0

    INDICATIONS ON OUTDOOR UNIT

  • 8/20/2019 Mr. Slim Air Conditioner Error Codes

    35/45

    Mr. Slim Air Conditioner Error Codes

    ttp://acerrorcode.com/mr-slim-air-conditioner-error-codes.html[03/03/2016 10:23:01 PM]

    LED1 (GREEN) = Flash Twice

    LED2 (RED) = Flash 3 times

    FAULTS = Communication or reception of remote control is unusual

    STANDARD = *

    INVERTER = *

    DETECTED UNIT = Remote Control

    THE PART TO BE CHECKED = 1) When using two or more remote controls, has a setup for master and slave

     been performed?

    2) Is a specified 2 core wire used for the electric wire? (03 – 1.25mm2 ) A wire with 3 or more cores is NG

     

    INDICATIONS ON REMOTE CONTROL = E3

    INDICATIONS ON OUTDOOR UNIT

    LED1 (GREEN) = Flash Twice

    LED2 (RED) = Flash 3 times

    FAULTS = Communication or reception of remote control is unusual

    STANDARD = *

    INVERTER = *

    DETECTED UNIT = Remote Control

    THE PART TO BE CHECKED = 1) When using two or more remote controls, has a setup for master and slave

     been performed?

    2) Is a specified 2 core wire used for the electric wire? (03 – 1.25mm2 ) A wire with 3 or more cores is NG

     

    INDICATIONS ON REMOTE CONTROL = E4

    INDICATIONS ON OUTDOOR UNIT

  • 8/20/2019 Mr. Slim Air Conditioner Error Codes

    36/45

    Mr. Slim Air Conditioner Error Codes

    ttp://acerrorcode.com/mr-slim-air-conditioner-error-codes.html[03/03/2016 10:23:01 PM]

    LED1 (GREEN) = Flash Twice

    LED2 (RED) = Flash 3 times

    FAULTS = Communication or reception of remote control is unusual

    STANDARD = *

    INVERTER = *

    DETECTED UNIT = Indoor Unit

    THE PART TO BE CHECKED = 1) When using two or more remote controls, has a setup for master and slave

     been performed?

    2) Is a specified 2 core wire used for the electric wire? (03 – 1.25mm2 ) A wire with 3 or more cores is NG

     

    INDICATIONS ON REMOTE CONTROL = E5

    INDICATIONS ON OUTDOOR UNIT

    LED1 (GREEN) = Flash Twice

    LED2 (RED) = Flash 3 times

    FAULTS = Communication or reception of remote control is unusual

    STANDARD = *

    INVERTER = *

    DETECTED UNIT = Indoor Unit

    THE PART TO BE CHECKED = 1) When using two or more remote controls, has a setup for master and slave

     been performed?

    2) Is a specified 2 core wire used for the electric wire? (03 – 1.25mm2 ) A wire with 3 or more cores is NG

     

    INDICATIONS ON REMOTE CONTROL = E6

  • 8/20/2019 Mr. Slim Air Conditioner Error Codes

    37/45

    Mr. Slim Air Conditioner Error Codes

    ttp://acerrorcode.com/mr-slim-air-conditioner-error-codes.html[03/03/2016 10:23:01 PM]

    INDICATIONS ON OUTDOOR UNIT

    LED1 (GREEN) = Flash Twice

     

    LED2 (RED) = Flash Twice

    FAULTS = Communication or reception between indoor unit and outdoor unit is unusual

    STANDARD = *

    INVERTER = *

    DETECTED UNIT = Indoor Unit

    THE PART TO BE CHECKED = 1) The line between indoor unit and outdoor unit is slack or unsuitable

    2) Is VVF with 3 cores used for the electric wire

    3) Is there a branch connection in middle of the line between indoor unit and outdoor unit

    4) Is the connection line between unit and outdoor unit wet

    5) Has fuse of outdoor board blown?

    6) Connector (CN01, 02 or 03) is slack or seperated

     

    INDICATIONS ON REMOTE CONTROL = E7

    INDICATIONS ON OUTDOOR UNIT

    LED1 (GREEN) = Flash Twice

    LED2 (RED) = Flash Twice

    FAULTS = Communication or reception between indoor unit and outdoor unit is unusual

    STANDARD = *

    INVERTER = *

    DETECTED UNIT = Indoor Unit

    THE PART TO BE CHECKED = 1) The line between indoor unit and outdoor unit is slack or unsuitable

  • 8/20/2019 Mr. Slim Air Conditioner Error Codes

    38/45

    Mr. Slim Air Conditioner Error Codes

    ttp://acerrorcode.com/mr-slim-air-conditioner-error-codes.html[03/03/2016 10:23:01 PM]

    2) Is VVF with 3 cores used for the electric wire

    3) Is there a branch connection in middle of the line between indoor unit and outdoor unit

    4) Is the connection line between unit and outdoor unit wet

    5) Has fuse of outdoor board blown?

    6) Connector (CN01, 02 or 03) is slack or seperated

     

    INDICATIONS ON REMOTE CONTROL = E8

    INDICATIONS ON OUTDOOR UNIT

    LED1 (GREEN) = Flash Twice

    LED2 (RED) = Flash Twice

    FAULTS = Communication or reception between indoor unit and outdoor unit is unusual

    STANDARD = *

    INVERTER = *

    DETECTED UNIT = Outdoor Unit

    THE PART TO BE CHECKED = 1) The line between indoor unit and outdoor unit is slack or unsuitable

    2) Is VVF with 3 cores used for the electric wire

    3) Is there a branch connection in middle of the line between indoor unit and outdoor unit

    4) Is the connection line between unit and outdoor unit wet

    5) Has fuse of outdoor board blown?

    6) Connector (CN01, 02 or 03) is slack or seperated

     

    INDICATIONS ON REMOTE CONTROL = E9

    INDICATIONS ON OUTDOOR UNIT

    LED1 (GREEN) = Flash Twice

  • 8/20/2019 Mr. Slim Air Conditioner Error Codes

    39/45

    Mr. Slim Air Conditioner Error Codes

    ttp://acerrorcode.com/mr-slim-air-conditioner-error-codes.html[03/03/2016 10:23:01 PM]

    LED2 (RED) = Flash Twice

    FAULTS = Communication or reception between indoor unit and outdoor unit is unusual

    STANDARD = *

    INVERTER = *

    DETECTED UNIT = Outdoor Unit

    THE PART TO BE CHECKED = 1) The line between indoor unit and outdoor unit is slack or unsuitable

    2) Is VVF with 3 cores used for the electric wire

    3) Is there a branch connection in middle of the line between indoor unit and outdoor unit

    4) Is the connection line between unit and outdoor unit wet

    5) Has fuse of outdoor board blown?

    6) Connector (CN01, 02 or 03) is slack or seperated

     

    INDICATIONS ON REMOTE CONTROL = EA

    INDICATIONS ON OUTDOOR UNIT

    LED1 (GREEN) = Flash Twice

    LED2 (RED) = Flash Once

    FAULTS = Wiring for connection between indoor unit and outdoor unit is wrong

    STANDARD = *

    INVERTER = *

    DETECTED UNIT = Outdoor Unit

    THE PART TO BE CHECKED = 1) The line between indoor unit and outdoor unit is slack or unsuitable

    2) Is VVF with 3 cores used for the electric wire

    3) Is there a branch connection in middle of the line between indoor unit and outdoor unit

    4) Is the connection line between unit and outdoor unit wet

  • 8/20/2019 Mr. Slim Air Conditioner Error Codes

    40/45

    Mr. Slim Air Conditioner Error Codes

    ttp://acerrorcode.com/mr-slim-air-conditioner-error-codes.html[03/03/2016 10:23:01 PM]

    5) Has fuse of outdoor board blown?

    6) Connector (CN01, 02 or 03) is slack or seperated

     

    INDICATIONS ON REMOTE CONTROL = Eb

    INDICATIONS ON OUTDOOR UNIT

    LED1 (GREEN) = Flash Twice

    LED2 (RED) = Flash Once

    FAULTS = Wiring for connection between indoor unit and outdoor unit is wrong (improper or seperated)

    STANDARD = *

    INVERTER = *

    DETECTED UNIT = Outdoor Unit

    THE PART TO BE CHECKED = 1) The line between indoor unit and outdoor unit is slack or unsuitable

    2) Is VVF with 3 cores used for the electric wire

    3) Is there a branch connection in middle of the line between indoor unit and outdoor unit

    4) Is the connection line between unit and outdoor unit wet

    5) Has fuse of outdoor board blown?

    6) Connector (CN01, 02 or 03) is slack or seperated

     

    INDICATIONS ON REMOTE CONTROL = EE

    INDICATIONS ON OUTDOOR UNIT

    LED1 (GREEN) = Flash Twice

    LED2 (RED) = Flash 4 times

    FAULTS = The combination is unusual

    STANDARD = *

  • 8/20/2019 Mr. Slim Air Conditioner Error Codes

    41/45

    Mr. Slim Air Conditioner Error Codes

    ttp://acerrorcode.com/mr-slim-air-conditioner-error-codes.html[03/03/2016 10:23:01 PM]

    INVERTER = *

    DETECTED UNIT = Indoor unit and Outdoor unit

    THE PART TO BE CHECKED = 1) Check the combination of indoor unit and outdoor unit

     

    INDICATIONS ON REMOTE CONTROL = EF

    INDICATIONS ON OUTDOOR UNIT

    LED1 (GREEN) = Flash Twice

    LED2 (RED) = Flash 4 times

    FAULTS = Non-definition error (M-NET system error / No target code)

    STANDARD = *

    INVERTER = *

    DETECTED UNIT = Indoor unit and Outdoor unit

    THE PART TO BE CHECKED = 1) Check the unusual indications of M-NET system’ remote control or centralized

     management system

     

    INDICATIONS ON REMOTE CONTROL = Ed

    INDICATIONS ON OUTDOOR UNIT

    LED1 (GREEN) = Flash Twice

    LED2 (RED) = Flash 5 times

    FAULTS = Communication between M-NET adapters is unusual

    STANDARD = *

    INVERTER = *

    DETECTED UNIT = Indoor unit and Outdoor unit

    THE PART TO BE CHECKED = 1) The connector between indoor control board and M-NET board seperated.

     

  • 8/20/2019 Mr. Slim Air Conditioner Error Codes

    42/45

    Mr. Slim Air Conditioner Error Codes

    ttp://acerrorcode.com/mr-slim-air-conditioner-error-codes.html[03/03/2016 10:23:01 PM]

     

    Related Posts:

    1. Mr. Slim Ai r Conditioner Error Codes

    2. Mitsubishi Mr Slim Air Conditioning Fault Codes

    CATEGORIES

     Acson

     Airwell

     Amana

     AmeriCool

     Aux

    Baxi

    Bryant

    Carrier 

    Chigo

    Chunlan

    Leave a ReplyYour email address will not be published. Required fields are marked *

    Comment 

    Name * 

    Email * 

    Website 

    Search

    Post Comment

    http://acerrorcode.com/mr-slim-air-conditioner-error-codes-2.htmlhttp://acerrorcode.com/mitsubishi-mr-slim-air-conditioning-fault-codes.htmlhttp://acerrorcode.com/brands/acsonhttp://acerrorcode.com/brands/airwellhttp://acerrorcode.com/brands/amanahttp://acerrorcode.com/brands/americoolhttp://acerrorcode.com/brands/auxhttp://acerrorcode.com/brands/baxihttp://acerrorcode.com/brands/bryanthttp://acerrorcode.com/brands/carrierhttp://acerrorcode.com/brands/chigohttp://acerrorcode.com/brands/chunlanhttp://acerrorcode.com/brands/chunlanhttp://acerrorcode.com/brands/chigohttp://acerrorcode.com/brands/carrierhttp://acerrorcode.com/brands/bryanthttp://acerrorcode.com/brands/baxihttp://acerrorcode.com/brands/auxhttp://acerrorcode.com/brands/americoolhttp://acerrorcode.com/brands/amanahttp://acerrorcode.com/brands/airwellhttp://acerrorcode.com/brands/acsonhttp://acerrorcode.com/mitsubishi-mr-slim-air-conditioning-fault-codes.htmlhttp://acerrorcode.com/mr-slim-air-conditioner-error-codes-2.html

  • 8/20/2019 Mr. Slim Air Conditioner Error Codes

    43/45

    Mr. Slim Air Conditioner Error Codes

    ttp://acerrorcode.com/mr-slim-air-conditioner-error-codes.html[03/03/2016 10:23:01 PM]

    Climatemaster 

    Comfortaire

    Comfortmaker 

    Daikin

    Danby

    Delonghi

    Derby

    Dometic

    Edgestar 

    Fedders

    Friedrich

    Frigidaire

    Fujitsu

    Fujitsu General

    Galanz

    GE

    Gree

    Haier 

    Hitachi

    Home

    Keeprite

    Kelvinator 

    Klimaire

    Koppel

    Lennox

    LG

    Lloyd

    McQuay

    Midea

    Mitsubishi

    Mitsubishi Electric

    http://acerrorcode.com/brands/climatemasterhttp://acerrorcode.com/brands/comfortairehttp://acerrorcode.com/brands/comfortmakerhttp://acerrorcode.com/brands/daikinhttp://acerrorcode.com/brands/danbyhttp://acerrorcode.com/brands/delonghihttp://acerrorcode.com/brands/derbyhttp://acerrorcode.com/brands/dometichttp://acerrorcode.com/brands/edgestarhttp://acerrorcode.com/brands/feddershttp://acerrorcode.com/brands/friedrichhttp://acerrorcode.com/brands/frigidairehttp://acerrorcode.com/brands/fujitsuhttp://acerrorcode.com/brands/fujitsu-generalhttp://acerrorcode.com/brands/galanzhttp://acerrorcode.com/brands/gehttp://acerrorcode.com/brands/greehttp://acerrorcode.com/brands/haierhttp://acerrorcode.com/brands/hitachihttp://acerrorcode.com/brands/homehttp://acerrorcode.com/brands/keepritehttp://acerrorcode.com/brands/kelvinatorhttp://acerrorcode.com/brands/klimairehttp://acerrorcode.com/brands/koppelhttp://acerrorcode.com/brands/lennoxhttp://acerrorcode.com/brands/lghttp://acerrorcode.com/brands/lloydhttp://acerrorcode.com/brands/mcquayhttp://acerrorcode.com/brands/mideahttp://acerrorcode.com/brands/mitsubishihttp://acerrorcode.com/brands/mitsubishi-electrichttp://acerrorcode.com/brands/mitsubishi-electrichttp://acerrorcode.com/brands/mitsubishihttp://acerrorcode.com/brands/mideahttp://acerrorcode.com/brands/mcquayhttp://acerrorcode.com/brands/lloydhttp://acerrorcode.com/brands/lghttp://acerrorcode.com/brands/lennoxhttp://acerrorcode.com/brands/koppelhttp://acerrorcode.com/brands/klimairehttp://acerrorcode.com/brands/kelvinatorhttp://acerrorcode.com/brands/keepritehttp://acerrorcode.com/brands/homehttp://acerrorcode.com/brands/hitachihttp://acerrorcode.com/brands/haierhttp://acerrorcode.com/brands/greehttp://acerrorcode.com/brands/gehttp://acerrorcode.com/brands/galanzhttp://acerrorcode.com/brands/fujitsu-generalhttp://acerrorcode.com/brands/fujitsuhttp://acerrorcode.com/brands/frigidairehttp://acerrorcode.com/brands/friedrichhttp://acerrorcode.com/brands/feddershttp://acerrorcode.com/brands/edgestarhttp://acerrorcode.com/brands/dometichttp://acerrorcode.com/brands/derbyhttp://acerrorcode.com/brands/delonghihttp://acerrorcode.com/brands/danbyhttp://acerrorcode.com/brands/daikinhttp://acerrorcode.com/brands/comfortmakerhttp://acerrorcode.com/brands/comfortairehttp://acerrorcode.com/brands/climatemaster

  • 8/20/2019 Mr. Slim Air Conditioner Error Codes

    44/45

    Mr. Slim Air Conditioner Error Codes

    ttp://acerrorcode.com/mr-slim-air-conditioner-error-codes.html[03/03/2016 10:23:01 PM]

    Recent Posts Comments

    Mitsubishi Heavy

    Mr. Slim

    Onida

    Panasonic

    Ramsond

    Rheem

    Rittal

    Ruud

    Samsung

    Sanyo

    Sharp

    Shinco

    TCL

    Teco

    Thermal Zone

    Thermo King

    Toshiba

    Trane

    Unionaire

    Westinghouse

    Whirlpool

    York

    Daikin AC Heat Pump Error Codes

    6:53 pm By admin

    Fault diagnosis by remote controller Read More »

    Samsung DVM S Error Codes

    10:20 am By admin

    E-101 Indoor unit communication error. No response from outdoor unit. (Indoor unit display) Read More »

    Daikin VRV 4 Fault Codes

    7:48 pm By admin

    In case a malfunction code appears on the indoor unit user interface display, contact your installer and inform the

    http://acerrorcode.com/brands/mitsubishi-heavyhttp://acerrorcode.com/brands/mr-slimhttp://acerrorcode.com/brands/onidahttp://acerrorcode.com/brands/panasonichttp://acerrorcode.com/brands/ramsondhttp://acerrorcode.com/brands/rheemhttp://acerrorcode.com/brands/rittalhttp://acerrorcode.com/brands/ruudhttp://acerrorcode.com/brands/samsunghttp://acerrorcode.com/brands/sanyohttp://acerrorcode.com/brands/sharphttp://acerrorcode.com/brands/shincohttp://acerrorcode.com/brands/tclhttp://acerrorcode.com/brands/tecohttp://acerrorcode.com/brands/thermal-zonehttp://acerrorcode.com/brands/thermo-kinghttp://acerrorcode.com/brands/toshibahttp://acerrorcode.com/brands/tranehttp://acerrorcode.com/brands/unionairehttp://acerrorcode.com/brands/westinghousehttp://acerrorcode.com/brands/whirlpoolhttp://acerrorcode.com/brands/yorkhttp://acerrorcode.com/daikin-ac-heat-pump-error-codes.htmlhttp://acerrorcode.com/daikin-ac-heat-pump-error-codes.htmlhttp://acerrorcode.com/samsung-dvm-s-error-codes.htmlhttp://acerrorcode.com/samsung-dvm-s-error-codes.htmlhttp://acerrorcode.com/daikin-vrv-4-fault-codes.htmlhttp://acerrorcode.com/daikin-vrv-4-fault-codes.htmlhttp://acerrorcode.com/samsung-dvm-s-error-codes.htmlhttp://acerrorcode.com/samsung-dvm-s-error-codes.htmlhttp://acerrorcode.com/daikin-ac-heat-pump-error-codes.htmlhttp://acerrorcode.com/daikin-ac-heat-pump-error-codes.htmlhttp://acerrorcode.com/brands/yorkhttp://acerrorcode.com/brands/whirlpoolhttp://acerrorcode.com/brands/westinghousehttp://acerrorcode.com/brands/unionairehttp://acerrorcode.com/brands/tranehttp://acerrorcode.com/brands/toshibahttp://acerrorcode.com/brands/thermo-kinghttp://acerrorcode.com/brands/thermal-zonehttp://acerrorcode.com/brands/tecohttp://acerrorcode.com/brands/tclhttp://acerrorcode.com/brands/shincohttp://acerrorcode.com/brands/sharphttp://acerrorcode.com/brands/sanyohttp://acerrorcode.com/brands/samsunghttp://acerrorcode.com/brands/ruudhttp://acerrorcode.com/brands/rittalhttp://acerrorcode.com/brands/rheemhttp://acerrorcode.com/brands/ramsondhttp://acerrorcode.com/brands/panasonichttp://acerrorcode.com/brands/onidahttp://acerrorcode.com/brands/mr-slimhttp://acerrorcode.com/brands/mitsubishi-heavy

  • 8/20/2019 Mr. Slim Air Conditioner Error Codes

    45/45

    Mr. Slim Air Conditioner Error Codes

     malfunction code, the unit type, and serial Read More »

    Samsung DVM S Hydro Unit Error Codes

    5:48 pm By admin

    Samsung DVM S Hydro Unit Error Codes Read More »

    Comfortmaker Air Conditioner Troubleshooting11:26 pm By admin

    Some models are factory equipped with the Comfort Alert Diagnostics device in the control box (refer to Figure

     Read More »

     © 2016 AC Error Code

    http://acerrorcode.com/daikin-vrv-4-fault-codes.htmlhttp://acerrorcode.com/samsung-dvm-s-hydro-unit-error-codes.htmlhttp://acerrorcode.com/samsung-dvm-s-hydro-unit-error-codes.htmlhttp://acerrorcode.com/comfortmaker-air-conditioner-troubleshooting.htmlhttp://acerrorcode.com/comfortmaker-air-conditioner-troubleshooting.htmlhttp://acerrorcode.com/http://acerrorcode.com/http://acerrorcode.com/comfortmaker-air-conditioner-troubleshooting.htmlhttp://acerrorcode.com/comfortmaker-air-conditioner-troubleshooting.htmlhttp://acerrorcode.com/samsung-dvm-s-hydro-unit-error-codes.htmlhttp://acerrorcode.com/samsung-dvm-s-hydro-unit-error-codes.htmlhttp://acerrorcode.com/daikin-vrv-4-fault-codes.html