MPRT MS - Vogel und Noot · 2011. 8. 25. · The MPRT MS is mounted using the two screws provided....
Transcript of MPRT MS - Vogel und Noot · 2011. 8. 25. · The MPRT MS is mounted using the two screws provided....
![Page 1: MPRT MS - Vogel und Noot · 2011. 8. 25. · The MPRT MS is mounted using the two screws provided. WHEREVER the Room Unit is mounted/used it should be out of direct sunlight, out](https://reader035.fdocuments.us/reader035/viewer/2022071407/60fdddcb03a78935c21943e5/html5/thumbnails/1.jpg)
OK
H
M
L
HEATTIMESPRESS TO ALTER YOUR HEATING TIMES
PRESS TO DEACTIVATE HEATING, OR HOLDFOR 5 SECONDS FOR MANUAL OVERRIDE
PRESS FOR 1 HOUR OF HIGH TEMPERATURE
PRESS TO ALTER YOUR “HIGH” TEMPERATURE
PRESS BOTH TOGETHER TO SET/VIEW CLOCK
PRESS TO ALTER YOUR “MID” TEMPERATURE
PRESS TO ALTER YOUR “LOW” TEMPERATURE
OFFMAN
1 Hr
High SettingCurrent
Temp
0 2 4 6 8 10 12 14 16 18 20 22 24
+PRESS HERE
MPRT MS PROGRAMMABLE ROOM THERMOSTAT
The MPRT MS is a programmable room thermostat. It senses the room temperature and if heat is called for, it activates the heating.
WIRING THE MPRT MS.The MPRT MS is wired directly to theheating equipment and powereddirectly from the main voltage supply.
MPRT MS
INSTALLATION INSTRUCTION
LOCATING THE ROOM UNITThe MPRT MS is mounted using the two screws provided.WHEREVER the Room Unit is mounted/used it should be out of direct sunlight, out of draughts, and clear of any heat source (e.g. radiators, fires or electronic equipment). For optimum use the unit should be sited between 1 and 1.5metres from the floor.
OK
H
M
L
HEATTIMESPRESS TO ALTER YOUR HEATING TIMES
PRESS TO DEACTIVATE HEATING, OR HOLDFOR 5 SECONDS FOR MANUAL OVERRIDE
PRESS FOR 1 HOUR OF HIGH TEMPERATURE
PRESS TO ALTER YOUR “HIGH” TEMPERATURE
PRESS BOTH TOGETHER TO SET/VIEW CLOCK
PRESS TO ALTER YOUR “MID” TEMPERATURE
PRESS TO ALTER YOUR “LOW” TEMPERATURE
OFFMAN
1 Hr
High SettingCurrent
Temp
0 2 4 6 8 10 12 14 16 18 20 22 24
OK
H
M
L
HEATTIMESPRESS TO ALTER YOUR HEATING TIMES
PRESS TO DEACTIVATE HEATING, OR HOLDFOR 5 SECONDS FOR MANUAL OVERRIDE
PRESS FOR 1 HOUR OF HIGH TEMPERATURE
PRESS TO ALTER YOUR “HIGH” TEMPERATURE
PRESS BOTH TOGETHER TO SET/VIEW CLOCK
PRESS TO ALTER YOUR “MID” TEMPERATURE
PRESS TO ALTER YOUR “LOW” TEMPERATURE
OFFMAN
1 Hr
High SettingCurrent
Temp
0 2 4 6 8 10 12 14 16 18 20 22 24
(1.0 - 1.5) m
Release the MPRT MS from its base by pressing at the arrow.
STEP 1.Remove terminal covers by removing terminal screws.
STEP 2.Thread control and power input wires through the knock-outs and attach base plate to the wall.
STEP 3.Connect control wires to terminals 2 and 3.Connect power input wires to terminals 4 and 6.
PRECAUTIONS AGAINST ELECTRIC SHOCK HAZARD.
Disconnect mains supply before moving cover.
Installation and maintenance must be carried out by suitably qualified personnel and in accordance with current IEE wiring regulations.
Do not mount to unearthed metal or metalised surfaces.
Fixed wiring installation must be employed. A class ’A’ switch, (having contact seperation of at least 3mm in all poles) must be incorporated in the fixed wiring as a means of disconnecting the supply. Use a fuse rated at least 3 amps to protect the system.
1 2 3
To heatingequipment
c
WIRING THE MPRT
To heatingequipment
MPRT Back Cover
123
The MPRT is wired directly to theheating equipment.
To heatingequipment
1
5
123
54
6
123
0C
Power input230 VAC 50Hz
Live
Neutral
456
1 2 3
To heatingequipment
c
WIRING THE MPRT
To heatingequipment
MPRT Back Cover
123
The MPRT is wired directly to theheating equipment.
To heatingequipment
1
5
123
54
6
123
0C
Power input230 VAC 50Hz
Live
Neutral
456
1 2 3
To heatingequipment
c
WIRING THE MPRT
To heatingequipment
MPRT Back Cover
123
The MPRT is wired directly to theheating equipment.
To heatingequipment
1
5
123
54
6
123
0C
Power input230 VAC 50Hz
Live
Neutral
456
![Page 2: MPRT MS - Vogel und Noot · 2011. 8. 25. · The MPRT MS is mounted using the two screws provided. WHEREVER the Room Unit is mounted/used it should be out of direct sunlight, out](https://reader035.fdocuments.us/reader035/viewer/2022071407/60fdddcb03a78935c21943e5/html5/thumbnails/2.jpg)
MYSON CONTROLSMYSON LTD., EASTERN AVENUE,TEAM VALLEY, GATESHEAD,TYNE & WEAR, NE11 0PGSALES OFFICE No. 0845 402 3434
IN ACCORDANCE WITH OUR POLICY OF CONTINUAL PRODUCT IMPROVEMENT WE RESERVE THE RIGHT TO AMEND THE SPECIFICATION OF THESE PRODUCTS WITHOUT PRIOR NOTIFICATION.
SETUP FOR SMART-START.To toggle the Smart-Start function between enabled and disabled, hold and down for 10 seconds. The button can now be used to toggle Smart-Start between active and deactivated.
CONFIGURING FOR WEEKLY ORDAILY TIMING.To toggle between weekly or daily time settings, hold and down for 10 seconds. The button can now be used to toggle between enabled and disabled.
CONFIGURING FOR GAS OR OILTo toggle between Oil or Gas hold and down for 10 seconds. The L button can be used to toggle between Oil and Gas.
OK
H
M
L
HEATTIMES
OFFMAN
1 Hr
OK
H
M
L
HEATTIMES
OFFMAN
1 Hr
OK
H
M
L
HEATTIMES
OFFMAN
1 Hr
OK
H
M
L
HEATTIMES
OFFMAN
1 Hr
OK
H
M
L
HEATTIMES
OFFMAN
1 Hr
OK
H
M
L
HEATTIMES
OFFMAN
1 Hr
TECHNICAL DATA:
Precision of measured temperature: 0.1oCSet temperature range: 6oC to 32oCElectrical Protection: Class IIIngress Protection: IP30Power Supply: 230 Vac +/- 10% , 50 HzStatutory Compliance: EMC 89\336\EEC, LVD 2006\95\EECPollution Situation: NormalSoftware Class: AOutput Relay Rating: 8(3)A 250Vac
ACTIVATING THE MPRT MS.Remove the plastic strip that is preventing the battery connection in the battery compartment.
The LCD should display as shown below.Re-assemble the unit to the base by first locating the right hand side and then closing the left .
MON TUE WED
THU FRI SAT SUN
High SettingCurrent
Temp
0 2 4 6 8 10 12 14 16 18 20 22 24
MON TUE WED THU FRI SAT SUN
0 2 4 6 8 10 12 14 16 18 20 22 24
High Setting
CurrentTime
MON TUE WED
THU FRI SAT SUN
TO ACCEPT & CONTINUE PRESS OK TO CHANGE VALUE PRESS OR
TO ACCEPT & CONTINUE PRESS OK TO CHANGE VALUE PRESS OR
FOR LOW PRESS “L”, FOR MEDIUM PRESS “M”, FOR HIGH PRESS “H”
TO ACCEPT & CONTINUE PRESS OK
Low Setting
Current
Temp
0 2 4 6 8 10 12 14 16 18 20 22 24
12 14 16 18 20 22 24
SAT SUN SMART START
12 14 16 18 20 22 24
SAT SUN SMART START
0 2 4 6 8 10 0 2 4 6 8 10
0 2 4 6 8 100 2 4 6 8 10
STEP 4.It is essential that the terminal cover must be replaced and secured with the screws removed in STEP 1.
OK
H
M
L
HEATTIMES
OFFMAN
1 Hr
OK
H
M
L
HEATTIMES
OFFMAN
1 Hr
SC2450 - R1
1 2 3
To heatingequipment
c
WIRING THE MPRT
To heatingequipment
MPRT Back Cover
123
The MPRT is wired directly to theheating equipment.
To heatingequipment
1
5
123
54
6
123
0C
Power input230 VAC 50Hz
Live
Neutral
456