MPA II. NIR IN A NEW LIGHT. · 2018. 5. 25. · • The MPA II comes with a new generation of light...
Transcript of MPA II. NIR IN A NEW LIGHT. · 2018. 5. 25. · • The MPA II comes with a new generation of light...
1
Lo spettrometro NIR MPA II: potenzialità applicative in campo agroalimentare
MPA II. NIR IN A NEW LIGHT.
Innovation with Integrity
Bruker Corporation Groups and Divisions(NASDAQ: BRKR)
Bruker BioSpin Group
Innovation with Integrity
Magnetic Resonance Spectroscopy (MRS)
Preclinical Imaging (PCI)
Bruker CALID Group
Mass spectrometry (Daltonics)
Infrared & Raman spectroscopy (Optics)
Bruker NANO Group
Bruker Nano Surface
Bruker EST (BEST)
Supercon wire and devices
Applied, Industrial and Clinical (AIC)
Bruker Nano Analytics
X-ray analysis
CBRNE (Detection)CALID = Chemical, Applied Markets, Life Science, In-Vitro Diagnostics, Detection
BEST: Bruker Energy and Supercon Technologies
5
Bruker Optics – Innovation Leader
FT-NIR Spectrometer
Research & Development Spectrometer
IFS
11
3v,
mod
ular
vac
uum
rese
arch
FT-
IR
IFS
11
2se
ries
, Bru
ker
Opt
ics
first
FT-
IR S
pect
rom
eter
IFS 85, first FT-IR for Routine Industry Applications
IRscope I, first FT-IR Microscope
VECTOR/N MATRIX MPA
IFS 1
20IF
S 8
8
IFS 28/N
FT-IR Routine Spectrometer
TENSORVECTORIFS 45 IFS 25
FT-IR Microscopes
IRscope II HYPERION
FT-Raman SpectrometerFRA 106 RFS 100
1998
Sentinel
Dispersive Raman
Senterra
ConfocheckIFS 28/BLife Science Systems
IFS 2
8
Ste
pSca
nR&
D 1
00 A
war
d
EQU
INO
X 5
5
IFS 6
6v
IFS 6
6
IFS
11
0,
Bru
ker‘s
first
purg
edFT
-IR S
pect
rom
ter
1974
1976
1981
1984
1985
1986
1988
2004
2002
2000
1990
1992
1994
1996
2006
2008
2011
2012
LUMOS
TANGO
ALPHA
Mobile-IR
2015
2016
Senterra II
MPAII
2018
INVENIO
6
Bruker Optics - Market Segments
CPPChemical, Pharma & Polymer
AFFAgri, Food & Feed
7
NIR: principio di base della tecnica
8
Principi della spettroscopia NIR
0 1 2 3 4 5 6 7Distanzadilegame
0
2
4
6
8
10
12
14
elaiznetoPid
esroM
v=0v=1
v=2v=3
-+
d B
A
0x
xµ∂ ≠ ∂
• Nella spettroscopia (N)IR si fornisce al sistema l’energia per passare dallo stato fondamentale a primo stato eccitato
• Non tutte le possibili vibrazioni sono in grado di interagire con le radiazioni elettromagnetiche
• regole di selezione
9
NIR: assorbimenti caratteristici
i legami chimici che assorbono (principalmente) in questa regione sono:• OH• CH• NH
10
NIR: Tecnologie disponibili
11
Perché FT?
• Eccellente rapporto segnale/rumore: tutte le lunghezze d’onda vengono raccolte simultaneamente vantaggio di Fellgett.
• Maggiore efficienza ottica Vantaggio di Jacquinot.• Elevata accuratezza della misura della lunghezza d’onda: è
garantita dall’utilizza di un riferimento interno (laser) che emette ad una lunghezza d’onda nota e stabile Vantaggio di Connes.
• Elevata risoluzione ottica: permette di ottenere spettri ad alta risoluzione, utili nel NIR non tanto per scopi applicativi quanto per permettere la verifica dell’accuratezza degli strumenti Standardizzazione degli strumenti
12
La trasformata di Fourier
OPD
Segn
ale
Det
ecto
rl
5001,0001,5002,0002,5003,0003,5004,000Numero d’onda, cm-1
0.10
0.20
0.30
0.40
Inte
nsità
Sin
gle-
chan
nel
Interferogramma SpettroFTIFT
2( ) ( ) i xS I x e dxπνν∞
−∞
= ∫
13
Interferometro
Sorgente
Detector
Specchiomobile M2
Specchiofisso M1
Beamsplitterx=0
14
ROCKSOLID Interferometer
Plane Mirrors in a classical Michelson Interferometer
Cube-Corner Mirrors in a ROCKSOLID-Interferometer
15
ROCKSOLID Interferometer
16
Bruker’s wear-free cube corner interferometer is state-of-the-art for modern near infrared spectrometers: Non-sensitive to vibrations Non-sensitive to temperature
fluctuations Highest repeatability: 0.006 cm-1
Excellent accuracy: 0.1cm-1
Highest resolution: 2 cm-1
…and permanently aligned!
ROCKSOLID Interferometer
Tecniche di campionamento
25/05/2018 17
Campione
Rivelatore
Sorgente
Trasmissione
Campione
RivelatoreSorgente
Riflettanza diffusa
Campione
RivelatoreSorgente
Specchio
Transflettanza
18
Each customer gets exactly the instrument that matches the application. There is no need to purchase anything that is not wanted or needed.
MPAII: Tailor-made Production
19
Maximum Flexibility
Sample Compartment
IntegratingSphere
Fiber OpticProbes
ExternalTransmission
20
Configurazione strumentale disponibile
MPA II MPA II basic, with integrated heatable and movable sample compartment for liquidsMPA II-R Extension module MPA-R (integrating sphere)IN312/C Rotating sample cup holder, 97mm w/o sample cupIN312-B Adaption for Petri dishesIN312-P Sample cup for IN312 (ABS)IN311-O/C Rotating sample cup holder, 51 mm w/o sample cupIN311-P Sample cup for IN311, 51mm diameterO/NIR_8.0+ OPUS/IR ver. 8.0O/QU-N OPUS Software "Quant"IN481S-2 Accessory for transflection measurements of liquidsIN441-001+ Glass vials, plain top, with flat bottom, 186 pieces w/o capsIN601CM Reduction insert for sample compartment for polymer cuvettes (IN455)IN601CRA Insert for cuvette-holder 10mmIN415QX-01 Rectangular flow cell (HELLMA 170-QX)
21
• Customizable workspaces• Easy measurement option• Setup of the instrument with
a few mouse clicks• Display informs user about
instrument status• Chemometrics quant
modeling (PLS) with self optimization function
Software OPUS: Easy Operation
22
• The MPA II comes with a new generation of light sources with a MTTF of 25,000 hours:
More peace of mind for the daily routine operation
Longer service intervals lead to reduced maintenance cost
Long-life NIR Light Source
23
• All detectors inside the MPA II are temperature-controlled and work linearly over the whole spectral range.
• This is essential for a successful quantitative analysis:
Highest accuracy and reliability
Highest reproducibility
High-sensitivity InGaAs detectors
24
• New durable diode laser for:
Highest wavenumber accuracy
Extra long lifetime (MTTF > 10 years)
Solid state laser technology
26
• easy sample insertion, no drawer or lid to open
• Moving insert for automated background measurements
• Temperature control as standard• A wide choice of vials, cuvettes
and flow cells available
Sample Compartment
27
• Ideal for the measurement of heterogeneous samples
• Wide range of accessories like sample rotators and vial holders available
• 30-position sample wheel for automated measurements
• Fully compatible to the compact TANGO-R and Matrix-I analyzers
Integrating Sphere
28
Integrating Sphere
Ideal for powders, granules or heterogeneous samples
Detector
Gold-coated integrating sphere
NIR Beam
Sample
29
• Small Rotator: Ø 50 mm• Large Rotator: Ø 97 mm• XXL Rotator: Ø 370 mm
Accessories: Rotators, Cups and Petri dishes
30
The MPA II is equipped with an integrated multiplexer so that two different probes can be attached:• investigation of solids and liquids
with only one instrument • no unplugging and changing of
the probes• quick and easy handling –
reproducible, reliable, and robust
Fiber Optic Probes
33
LSM Module
Liquid Samplig Module
• Fully automated liquid analysis and cleaning
• Homogenizer for raw milk
• Bypass pump for other liquid samples, e.g. cream and whey
• Handles high viscosity liquids, e.g. milk drinks, whey protein concentrates and permeates
34
LSM Module
Liquid Samplig Module
• 1 mm quartz Flowcell, easy to clean
• Calibrations can be easilytransferred to in-line applications
• Automatic routine for Homogenizer valve efficiency test
35
Performance example
36
Milk and Dairy Products with MPAII-D
MPA II: The tailor-made Solution for your Quality Control
http://www.niritalia2018.sisnir.org/
http://www.nir2019.com/
Innovation with Integrity