Most Frequently Cited Serious Violations
description
Transcript of Most Frequently Cited Serious Violations
Most Frequently CitedSerious Violations
Construction – FY 2007
Number of Serious Violations - FY 2007 2
2043
1889
1612
1480
1463
1247
1219
1206
1155
889
501(b)(13) - M
501(b)(1) - M
100(a) - E
451(g)(1) - L
453(b)(2)(v) - L
503(a)(1) - M
1053(b)(1) - X
451(e)(1) - L
451(b)(1) - L
454(a) - L
Most Frequently Cited Serious Violationsin Construction – FY 2007
Aerial Lifts - Body belt and lanyard
Head protection
Portable ladders 3 feet above landing surface
Training for employees using scaffolds
Fall hazards training program
Scaffolds - Fall protection
Fall protection - Unprotected sides & edgesFall protection – Residential construction 6’ or more
Scaffolds - Platform constructionScaffolds - Access
Stan
dard
& S
ubpa
rt -
1926
.
-
There were also 359 Section 5(a)(1) violations cited in construction SIC codes (1500 – 1799) during this period.
Number of Serious Violations - FY 2007 3
861
750
705
231
92
21(b)(2)
20(b)(2)
20(b)(1)
25(a)
28(a)
Stan
dard
- 19
26.
Subpart C - General Safety & Health(1926.20 - 35)
Employee training programs
Inspections by competent person
Initiate and maintain accident prevention programs
Personal protective equipment – Employer responsibility
Housekeeping
Number of Serious Violations - FY 2007 4
Subpart D - Occupational Health & Environmental Controls
(1926.50 - 66)
42
38
32
28
25
25
50(c)
62(d)(1)(i)
62(d)(2)(v)(A)
55(a)
62(d)(2)(v)(B)
62(d)(2)(v)(F)
Stan
dard
- 19
26.
Lead – Interim respiratory protection
Lead - Exposure assessment
First aid training
Lead – Interim personal protective clothing & equipment
Exposure to air contaminants
Lead – Interim training
Number of Serious Violations - FY 2007 5
Subpart E - Personal Protective & Life Saving Equipment
(1926.95 - 107)
1612
860
340
21
17
100(a)
102(a)(1)
95(a)
106(a)
102(a)(2)
Stan
dard
- 19
26.
Head protection
Required eye & face protection – ANSI requirements
PPE - Provided, used & maintained
Eye & face protection
Life jackets/vests
Number of Serious Violations - FY 2007 6
Subpart F - Fire Protection & Prevention(1926.150 - 159)
28
25
25
23
68150(c)(1)(i)
152(a)(1)
150(c)(1)(iv)
150(c)(1)(vi)
153(j)
Stan
dard
- 19
26.
Extinguishers within 50 ft. of flammables/combustibles
2A fire extinguishers - Building area
Extinguishers on each floor
Storage of LPG containers
Flammable/combustible liquids – Approved containers
Number of Serious Violations - FY 2007 7
46
35
24
16
5
200(g)(2)
200(g)(1)
201(a)
202
200(a)
Stan
dard
- 19
26.
Subpart G - Signs, Signals & Barricades(1926.200 - 203)
Traffic control signs/devices - Requirements
Barricades - Requirements
Flaggers – Proper signaling by & use of
Traffic signs at points of hazard
Visible signs & symbols
Number of Serious Violations - FY 2007 8
Subpart H - Materials Handling, Storage, Use & Disposal
(1926.250 - 252)
29
18
16
11
5
251(a)(1)
252(a)
251(e)(8)(iii)
251(e)(8)
251(a)(4)
Stan
dard
- 19
26.
Rigging equipment inspection & removal from service
Torn/cut synthetic web slings - Removal from service
Rigging equipment lifting accessories – Marked & tested
Exterior drop chutes
Synthetic web slings - Removal from service
Number of Serious Violations - FY 2007 9
Subpart I - Tools: Hand & Power(1926.300 - 307)
129
92
49
49
45
304(f)
300(b)(1)
300(b)(2)
304(i)(1)
304(d)
Stan
dard
- 19
26.
Woodworking tools - ANSI requirements
Guarding of rotating/moving parts
Tools designed for guards - Guards in place
Guarding of ripsaws
Guarding of portable circular saws
Number of Serious Violations - FY 2007 10
Subpart J - Welding & Cutting(1926.350 -354)
80
57
17
17
17
350(a)(9)
350(a)(10)
350(a)(7)
351(b)(4)
352(d)
Stan
dard
- 19
26.
Cylinders secured upright
Cables needing repair
Oxygen cylinder storage
Fire extinguishing equipment in area
Use of device to keep cylinders steady while in use
Number of Serious Violations - FY 2007 11
Subpart K - Electrical(1926.400 - 449)
385
367
197
162
159
404(f)(6)
404(b)(1)(i)
403(b)(2)
405(g)(2)(iv)
416(e)(1)
Stan
dard
- 19
26.
Ground fault protection
Grounding path
Equipment installation & use
Worn/frayed cords or cables
Flexible cords – Strain relief
Number of Serious Violations - FY 2007 12
Subpart L - Scaffolds(1926.450 - 454)
1480
1463
1206
1155
889
451(g)(1)
453(b)(2)(v)
451(e)(1)
451(b)(1)
454(a)
Stan
dard
- 19
26.
Scaffolds above 10 ft. - Fall protection
Scaffold access
Scaffold platform construction
Aerial lifts - Body belt & lanyard
Training for employees using scaffolds
Number of Serious Violations - FY 2007 13
2043
1889
1247
541
343
501(b)(13)
501(b)(1)
503(a)(1)
501(b)(10)
501(b)(11)
Stan
dard
- 19
26.
Subpart M - Fall Protection(1926.500 - 503)
Fall protection - Residential construction 6’ or more
Fall hazards training program
Fall protection - Unprotected sides & edges
Fall protection - Roofing work on low-slope roofsFall protection – Steep roofs
Number of Serious Violations - FY 2007 14
24
21
21
17
16
550(a)(1)
550(a)(9)
550(a)(15)(i)
550(b)(2)
550(a)(19)
Stan
dard
- 19
26.
Subpart N - Cranes, Derricks, Hoists, Elevators & Conveyors
(1926.550 - 556)
Cranes and derricks – Manufacturers’ specifications
Clearances between power lines & equipment
Swing radius at rear of crane barricaded
Employees kept clear of loads
ANSI Requirements
Number of Serious Violations - FY 2007 15
Subpart O - Motor Vehicles, Mechanized Equipment, & Marine Operations
(1926.600 - 606)
50
42
39
32
31
602(c)(1)(vi)
602(a)(9)(ii)
602(c)(1)(viii)(A)
602(c)(1)(vii)
602(a)(9)(i)
Stan
dard
- 19
26.
Earthmoving/compacting equipment - Reverse signal alarm
Bi-directional machines - Horn
Industrial trucks – Unauthorized personnel
Lifting/hauling equipment - Use of safety platform
Industrial trucks - ANSI B56.1-1969
Number of Serious Violations - FY 2007 16
Subpart P - Excavations(1926.650 - 652)
88
332
384
440
828652(a)(1)
651(c)(2)
651(k)(1)
651(j)(2)
651(k)(2)
Stan
dard
- 19
26.
Employee protection in excavations - Protective system use
Inspections by competent personProtection from falling/rolling materials/equipment
Egress from trench excavations
Competent person inspection - Employees removed from hazard
Number of Serious Violations - FY 2007 17
Subpart Q - Concrete & Masonry Construction(1926.700 - 706)
256
22
15
9
701(b)
706(b)
706(a)(1)
703(a)(2)
Stan
dard
- 19
26.
Reinforcing steel - Guarding
Masonry walls - Bracing
Masonry walls – Limited access zone prior to start
Formwork – Drawings/plans available on jobsite
Number of Serious Violations - FY 2007 18
Subpart R – Steel Erection(1926.750 - 761)
249
60
24
15
8
8
760(a)(1)
761(b)
760(b)(3)
760(b)(1)
760(c)(3)
760(d)(1)
Stan
dard
- 19
26.
Protection from fall hazards
Controlled Decking Zone designated & marked
Fall protection for connectors – 15’ to 30’
Fall hazard training
Fall protection for connectors – More than 2 stories or 30’
Fall protection equipment – Conform to 1926.502
Number of Serious Violations - FY 2007 19
56
15
11
11
9
850(a)
852(a)
850(i)
856(b)
859(g)
Stan
dard
- 19
26.
Subpart T - Demolition(1926.850 - 860)
Engineering survey - Prior to operations
Chutes – No material dropped outside structure unless protected
Floor openings – Curbs or stop-logs
Inspections by competent person
Floor openings covered
Number of Serious Violations - FY 2007 20
Subpart X - Ladders(1926.1050 - 1060)
Stairrails & handrails1219
381
333
288
238
1053(b)(1)
1052(c)(1)
1060(a)
1053(b)(4)
1053(b)(13)
Stan
dard
- 19
26.
Portable ladders 3 feet above landing surface
Top of stepladder improperly used
Training program
Appropriate use of ladders
Number of Serious Violations - FY 2007 21
Subpart Z - Toxic & Hazardous Substances(1926.1100 - 1152)
26
20
19
15
13
1101(e)(1)
1101(f)(2)(i)
1101(k)(9)(i)
1101(k)(3)(i)
1101(f)(1)(i)Stan
dard
- 19
26.
Asbestos - Exposure assessment by competent person
Asbestos - Class I, II, & III asbestos work in regulated areas
Asbestos – Identify AMC/PACM* before work
Asbestos - Training program
Asbestos - Monitoring
* Asbestos-containing material/Presumed asbestos-containing material
Number of Serious Violations - FY 2007 22
73
67
45
38
30
134(c)(1)
134(e)(1)
134(d)(1)(iii)
134(f)(1)
134(k)(1)
Respiratory Protection (1910.134)Cited in Construction SIC Codes
Medical evaluation to determine employee’s ability to use respirator
Employee demonstration of knowledge of respirator
Evaluation of respiratory hazards
Qualitative or quantitative fit testing
Written respiratory protection program
Stan
dard
: 191
0.
Number of Serious Violations - FY 2007 23
82
27
23
9
178(l)(1)(i)
178(l)(1)(ii)
178(l)(6)
178(l)(2)(ii)
Powered Industrial TruckOperator Training [1910.178(l)]Cited in Construction SIC Codes
Training prior to truck operation
Operator Training – Formal, practical & performance
Operator certification
Stan
dard
: 191
0.
Operator competency
Number of Serious Violations - FY 2007 24
Hazard Communication (1910.1200)Cited in Construction SIC Codes
278
128
93
89
74
1200(e)(1)
1200(h)(1)
1200(g)(8)
1200(g)(1)
1200(h)
Written program
Information & training
Material Safety Data Sheets readily accessible
Training initially & for new hazards
Material Safety Data Sheets
Stan
dard
: 191
0.