Morpho Biometric terminals - Biotime Technology...Let rest hand palm on the shell of the terminal...

15
Morpho Biometric terminals Finger position recommendations

Transcript of Morpho Biometric terminals - Biotime Technology...Let rest hand palm on the shell of the terminal...

Page 1: Morpho Biometric terminals - Biotime Technology...Let rest hand palm on the shell of the terminal Keep finger straight. 11 SSE-0000084555-02/ Finger position recommendations / March

Morpho Biometric terminals

Finger position recommendations

Page 2: Morpho Biometric terminals - Biotime Technology...Let rest hand palm on the shell of the terminal Keep finger straight. 11 SSE-0000084555-02/ Finger position recommendations / March

1 1

1

SSE-0000084555-02/ Finger position recommendations / March 2013

How to get the best quality

Finger position recommendations

Acquisition needs to be done with extreme care, in order to :

get the best image quality

increase recognition performance

reduce recognition time

Then, it is highly recommended to :

Maximize the contact between the fingerprint and the sensor

Exert firm, but not excessive, finger pressure on the surface of the sensor

Do not press too hard

Do not slide nor roll the finger across the sensor

Do not move the finger during acquisition

Wait for the extinction of sensor backlight before removing the finger

Page 3: Morpho Biometric terminals - Biotime Technology...Let rest hand palm on the shell of the terminal Keep finger straight. 11 SSE-0000084555-02/ Finger position recommendations / March

2 2

2

SSE-0000084555-02/ Finger position recommendations / March 2013

Fingerprint sensors

Page 4: Morpho Biometric terminals - Biotime Technology...Let rest hand palm on the shell of the terminal Keep finger straight. 11 SSE-0000084555-02/ Finger position recommendations / March

3 3

3

SSE-0000084555-02/ Finger position recommendations / March 2013

Fingerprint most useful area

Finger position recommendations

The most useful area is located around the centre of the fingerprint

Fingerprint central area must be aligned with sensor centre

Area containing

the maximum

information

Page 5: Morpho Biometric terminals - Biotime Technology...Let rest hand palm on the shell of the terminal Keep finger straight. 11 SSE-0000084555-02/ Finger position recommendations / March

4 4

4

SSE-0000084555-02/ Finger position recommendations / March 2013

Finger Height

Finger position recommendations

Align center of 1st phalanx with sensor center

Page 6: Morpho Biometric terminals - Biotime Technology...Let rest hand palm on the shell of the terminal Keep finger straight. 11 SSE-0000084555-02/ Finger position recommendations / March

5 5

5

SSE-0000084555-02/ Finger position recommendations / March 2013

Finger angle

Finger position recommendations

The finger must be parallel to sensor sides

IDEAL

POSITION

Page 7: Morpho Biometric terminals - Biotime Technology...Let rest hand palm on the shell of the terminal Keep finger straight. 11 SSE-0000084555-02/ Finger position recommendations / March

6 6

6

SSE-0000084555-02/ Finger position recommendations / March 2013

Finger inclination

Finger position recommendations

Finger must be parallel to the sensor surface

IDEAL

POSITION

Page 8: Morpho Biometric terminals - Biotime Technology...Let rest hand palm on the shell of the terminal Keep finger straight. 11 SSE-0000084555-02/ Finger position recommendations / March

7 7

7

SSE-0000084555-02/ Finger position recommendations / March 2013

Finger rotation

Finger position recommendations

Finger must be parallel to the sensor surface

IDEAL

POSITION

Page 9: Morpho Biometric terminals - Biotime Technology...Let rest hand palm on the shell of the terminal Keep finger straight. 11 SSE-0000084555-02/ Finger position recommendations / March

8 8

8

SSE-0000084555-02/ Finger position recommendations / March 2013

Fingerprint + Vein sensors

Page 10: Morpho Biometric terminals - Biotime Technology...Let rest hand palm on the shell of the terminal Keep finger straight. 11 SSE-0000084555-02/ Finger position recommendations / March

9 9

9

SSE-0000084555-02/ Finger position recommendations / March 2013

Fingerprint and vein network most useful areas

Finger position recommendations

Fingerprint : the most useful area is

located around the centre (1st phalanx)

Fingerprint central area must be

aligned with sensor centre

Finger Vein (blood vessel pattern): the

area of interest is usually located

between the 1st and the 3rd phalanxes

The finger tip must be placed in full

contact with the round shape guide

(please refer to next pages)

Area containing

the maximum

information

Page 11: Morpho Biometric terminals - Biotime Technology...Let rest hand palm on the shell of the terminal Keep finger straight. 11 SSE-0000084555-02/ Finger position recommendations / March

10 10

10

SSE-0000084555-02/ Finger position recommendations / March 2013

Fingerprint and vein sensors

Finger position recommendations

Good position

Place finger tip on the round shape guide by the LED indicator.

In case of long nail, place nail above the LED indicator with

finger tip touching the round shape guide

Keep finger tip in contact with the round shape guide (1).

Make sure that fingerprint is in contact with the optical

transparent surface (2).

Place finger root on its positioning guide (3).

Let rest hand palm on the shell of the terminal

Keep finger straight.

Page 12: Morpho Biometric terminals - Biotime Technology...Let rest hand palm on the shell of the terminal Keep finger straight. 11 SSE-0000084555-02/ Finger position recommendations / March

11 11

11

SSE-0000084555-02/ Finger position recommendations / March 2013

Fingerprint and vein sensors

Finger position recommendations

Bad positions

Do not place finger tip on top of the LED indicator.

Do not place the finger tip on the sensor surface : it must be in

contact with the round shape guide.

Do not lift finger.

Do not bend finger.

Finger must be parallel to the guide walls.

Do not roll the finger.

Do not bend finger.

Do not arch finger backwards

Do not tense finger and do not press strongly so as to avoid

blood vessels constriction.

Page 13: Morpho Biometric terminals - Biotime Technology...Let rest hand palm on the shell of the terminal Keep finger straight. 11 SSE-0000084555-02/ Finger position recommendations / March

12 12

12

SSE-0000084555-02/ Finger position recommendations / March 2013

Recommendation for all sensors

Page 14: Morpho Biometric terminals - Biotime Technology...Let rest hand palm on the shell of the terminal Keep finger straight. 11 SSE-0000084555-02/ Finger position recommendations / March

13 13

13

SSE-0000084555-02/ Finger position recommendations / March 2013

Troubleshooting

Finger position recommendations

When finger biometric data acquisition is difficult, please follow the

recommendations listed below :

The finger is cold

Solution : warm up the finger

The finger is wet

Solution : wipe the finger

The finger is dry

Solution : warm up the finger and/or add a little bit of humidity

The finger is dirty

Solution: wash hands

Remove bandages or adhesive tapes from the fingerprint area, and from

the 2nd phalanx of the finger

Do not press or tense finger to avoid blood vessels constriction

Page 15: Morpho Biometric terminals - Biotime Technology...Let rest hand palm on the shell of the terminal Keep finger straight. 11 SSE-0000084555-02/ Finger position recommendations / March

14 14

14

SSE-0000084555-02/ Finger position recommendations / March 2013

Contacts

Finger position recommendations

Registered Office :

11, boulevard Gallieni

92130 Issy-les-Moulineaux

FRANCE

http://www.morpho.com/

Customer Service (repair) :

Morpho

SAV terminaux biométriques

Boulevard Lénine - BP428

76805 Saint Etienne du Rouvray

FRANCE

Tel : +33 2 35 64 53 52

Customer assistance (hotline):

Morpho

Support terminaux biométriques

18, Chaussée Jules César

95520 OSNY - FRANCE

[email protected]

Tel : +33 1 58 11 39 19

(Monday to Friday, 09h00 to 18h00, French time)

www.biometric-terminals.com

Login and password required to access private areas