DN
SELECTED COLORBOND GUTTERS, FASCIAS AND
DOWNPIPES TO THE MANUFACTURERS SPECIFICATIONS
Ar041
Ar041
Ar042
Ar042
SELECTED PLASTERBOARD LININGS FIXED TO THE
MANUFACTURERS SPECIFICATIONS & THE SCHEDULE OF
SPECIFICATIONS DETAILS
SELECTED BALUSTRADE, 1000 HIGH, 125
OPENINGS TO BCA CLAUSE 3.9.2
240 x 45 F7 KILN DRIED TREATED PINE
TREADS TO BCA REQUIREMENTS
90 x 90 F7 KILN DRIED TREATED PINE OR 100 x 100
HARDWOOD POSTS TO THE OWNERS DETAILSEXTENT OF EXISTING ROOFLINE
SELECTED 15mm AC OR 15mm STRUCTURAL GRADE PLY. WETSEAL TO
MANUFACTURERS SPECIFICATIONS, SELECTED TILES OVER FIXED TO
THE MANUFACTURERS SPECIFICATIONS
NOTE - BRACING AND TIE-DOWN DETAILS
TO THE ENGINEERS DETAILS AND AS1684.2
NOTE - : ALL TIMBER TO BE INSTALLED TO
THE MANUFACTURERS SPECIFICATIONS
Existing
BedExisting
BedExisting
Bath
Existing
Kitchen
Existing
Living Existing
Porch
Existing
Entry
100 1710 90 6000
PROPOSED
LIVING
100
1100
100
5340
100
6740 APPROX (SITE CONFIRM)
7900
W2 W1
W4 W5
SD1
W3
2/770PROPOSED
L'DRY CUP'D
1800 100 6000
PROPOSED
DECK
B1 OVER
B1 OVER
B1 OVER
SELECTED ALUMINIUM WINDOWS AND DOORS TO THE OWNERS
DETAILS AND MANUFACTURERS SPECIFICATIONS
SELECTED WEATHERBOARDS, SIMILAR TO EXISTING
DWELLING, FIXED TO THE MANUFACTURERS
SPECIFICATIONS. BLEND AND STAGGER AS REQUIRED TO
CONCEAL LINE OF NEW ADDITIONS
DEMOLISH WALLS, ROOF, FLOOR AND FOOTINGS AS REQUIRED
FOR PROPOSED SCOPE OF WORKS SHOWN ON PLANS
90 x 45 F7 STUD WALLS. WALL FRAMING, BRACING AND TIE-DOWNS TO
THE WALL MANUFACTURERS SPECIFICATIONS AND AS1684
DP
DP
SELECTED KILN DRIED TREATED PINE OR
HARDWOOD DECKING
1800
REMOVE EXISTING WINDOW AS REQUIRED FOR
PROPOSED SERVERY OPENING AS SHOWN
Beams To Engineers detailsB1
Member Description SizeMember Schedule
Plan Vision Australia12A Whitehaven Drive, Lakelands
W/ (02) 4954 2422 M/ 0414 011 483
Drawn By:
Date:
Sheet:
Client:
Address:
Drawing No:
Scale: @ A3 1 : 100
MWG
Ar01
Additions & Alterations
1 : 100
1
Ground Floor
NORTH
SURVEY NOTE :
Boundary dimensions are assumed only and takenfrom site information, others or owners information.Confirm boundaries before commencement ofconstruction.
Full project specific detailed survey plans havenot been supplied to Plan Vision for planningpurposes. See schedule of specifications fordetails.
ASSUMED W33N WIND SPEED
ASSUMED CLASS 'M'
BUILDERS NOTE:-
* Materials are under no circumstances to beordered direct off Additions Plans. * Materials tobe ordered are only to be ordered from a Buildersor applicable product manufacturers seperate siteconfirmed Materials list. * Additions plans are notintended to be the absolute medium forconstruction information accuracy due to existingbuildings discrepencies and existing buildingshidden characteristics. See schedule ofspecifications for further details.
BUILDERS NOTE
:
Use Dimensions in preference to scale. Site verifyall dimensions before ordering Materials. Footingsinformation shown on these plans may have to bechanged if Builders site excavations reveal non-virgin ground. Consultation of Plan Vision AustraliaPty Ltd would then be necessary to determine therequired changes.
Builder to inspect adequacy of existing footings& piers for proposed scope of works. Replaceexisting footings & sub floor members asnecessary
Revision Schedule
Date DescriptionIssued
by
Door Schedule
Level Mark Width Height Type
Ground Floor SD1 1847 2121 ASD
Window Schedule
Level Mark
Widt
h Height Type
Ground Floor W5 1791 590 ASW
Ground Floor W4 1791 590 ASW
Ground Floor W3 843 2042 ASW+FIXED
Ground Floor W2 1791 590 ASW
Ground Floor W1 1791 590 ASW
-
12720
Ground Floor FCL
12720
Ground Floor FCL
10000
Ground Floor
10000
Ground Floor
2720
2720
PROPOSED GROUNDLINE
SD1 W3
ROOF PITCH TO
MATCH EXISTING
EXISTING GROUNDLINE
SELECTED COLORBOND GUTTERS, FASCIAS AND
DOWNPIPES TO THE MANUFACTURERS SPECIFICATIONS
230 x 230 BRICKWORK PIERS. SEE
FOOTINGS PLAN AND DETAILS
SELECTED CONCRETE ROOF TILES TO OWNERS DETAILS
AND FIXED TO THE MANUFACTURERS SPECIFICATIONS
90 x 45 F7 STUD WALLS. WALL FRAMING, BRACING AND TIE-DOWNS TO
THE WALL MANUFACTURERS SPECIFICATIONS AND AS1684
SELECTED KILN DRIED TREATED PINE OR
HARDWOOD DECKING
240 x 45 F7 KILN DRIED TREATED PINE
TREADS TO BCA REQUIREMENTS
SELECTED BALUSTRADE, 1000 HIGH, 125
OPENINGS TO BCA CLAUSE 3.9.2
90 x 90 F7 KILN DRIED TREATED PINE OR 100 x 100
HARDWOOD POSTS TO THE OWNERS DETAILS
ROOF TRUSSES OVER. ROOF TRUSSES, ROOF BRACING AND TIE DOWNS
TO THE MANUFACTURERS SPECIFICATIONS AND AS1684
SELECTED ALUMINIUM WINDOWS AND DOORS TO THE OWNERS
DETAILS AND MANUFACTURERS SPECIFICATIONS
CUT AS REQUIRED FOR MINIMUM 250 SUB-FLOOR
CLEARANCE TO BCA REQUIREMENTS
SELECTED WEATHERBOARDS, SIMILAR TO EXISTING DWELLING, FIXED
TO THE MANUFACTURERS SPECIFICATIONS
DPDP
MATCH EXISTING
EAVES TO
12720
Ground Floor FCL
12720
Ground Floor FCL
10000
Ground Floor
10000
Ground Floor
2720
2720
ROOF PITCH TO
MATCH EXISTING
PROPOSED GROUNDLINE
EXISTING GROUNDLINE
SELECTED COLORBOND GUTTERS, FASCIAS AND
DOWNPIPES TO THE MANUFACTURERS SPECIFICATIONS
CUT AS REQUIRED FOR MINIMUM 250 SUB-FLOOR
CLEARANCE TO BCA REQUIREMENTS
230 x 230 BRICKWORK PIERS. SEE
FOOTINGS PLAN AND DETAILS
SELECTED CONCRETE ROOF TILES TO OWNERS DETAILS
AND FIXED TO THE MANUFACTURERS SPECIFICATIONS
SELECTED ALUMINIUM WINDOWS AND DOORS TO THE OWNERS
DETAILS AND MANUFACTURERS SPECIFICATIONS
SELECTED WEATHERBOARDS, SIMILAR TO EXISTING DWELLING, FIXED
TO THE MANUFACTURERS SPECIFICATIONS. BLEND AND STAGGER AS
REQUIRED TO CONCEAL LINE OF NEW ADDITIONS
90 x 45 F7 STUD WALLS. WALL FRAMING, BRACING AND TIE-DOWNS TO
THE WALL MANUFACTURERS SPECIFICATIONS AND AS1684
DP
W1 W2
EXTENT OF EXISTING ROOFLINE
EAVES TO
MATCH EXISTING
SELECTED KILN DRIED TREATED PINE OR
HARDWOOD DECKING
240 x 45 F7 KILN DRIED TREATED PINE
TREADS TO BCA REQUIREMENTS
SELECTED BALUSTRADE, 1000 HIGH, 125
OPENINGS TO BCA CLAUSE 3.9.2
90 x 90 F7 KILN DRIED TREATED PINE OR 100 x 100
HARDWOOD POSTS TO THE OWNERS DETAILS
ROOF TRUSSES OVER. ROOF TRUSSES, ROOF BRACING AND TIE DOWNS
TO THE MANUFACTURERS SPECIFICATIONS AND AS1684
EXISTING DWELLING
Plan Vision Australia12A Whitehaven Drive, Lakelands
W/ (02) 4954 2422 M/ 0414 011 483
Drawn By:
Date:
Sheet:
Client:
Address:
Drawing No:
Scale: @ A3 1 : 100
MWG
Ar02
Additions & Alterations
1 : 100
1
West Elevation
1 : 100
2
North Elevation
SURVEY NOTE :
Boundary dimensions are assumed only and takenfrom site information, others or owners information.Confirm boundaries before commencement ofconstruction.
Full project specific detailed survey plans havenot been supplied to Plan Vision for planningpurposes. See schedule of specifications fordetails.
ASSUMED W33N WIND SPEED
ASSUMED CLASS 'M'
BUILDERS NOTE:-
* Materials are under no circumstances to beordered direct off Additions Plans. * Materials tobe ordered are only to be ordered from a Buildersor applicable product manufacturers seperate siteconfirmed Materials list. * Additions plans are notintended to be the absolute medium forconstruction information accuracy due to existingbuildings discrepencies and existing buildingshidden characteristics. See schedule ofspecifications for further details.
BUILDERS NOTE
:
Use Dimensions in preference to scale. Site verifyall dimensions before ordering Materials. Footingsinformation shown on these plans may have to bechanged if Builders site excavations reveal non-virgin ground. Consultation of Plan Vision AustraliaPty Ltd would then be necessary to determine therequired changes.
Builder to inspect adequacy of existing footings& piers for proposed scope of works. Replaceexisting footings & sub floor members asnecessary
Revision Schedule
Date DescriptionIssued
by
-
12720
Ground Floor FCL
12720
Ground Floor FCL
10000
Ground Floor
10000
Ground Floor
2720
2720
EXISTING GROUNDLINE
ROOF PITCH TO
MATCH EXISTING
SELECTED COLORBOND GUTTERS, FASCIAS AND
DOWNPIPES TO THE MANUFACTURERS SPECIFICATIONS
230 x 230 BRICKWORK PIERS. SEE
FOOTINGS PLAN AND DETAILS
SELECTED CONCRETE ROOF TILES TO OWNERS DETAILS
AND FIXED TO THE MANUFACTURERS SPECIFICATIONS
SELECTED ALUMINIUM WINDOWS AND DOORS TO THE OWNERS
DETAILS AND MANUFACTURERS SPECIFICATIONS
SELECTED WEATHERBOARDS, SIMILAR TO EXISTING DWELLING, FIXED
TO THE MANUFACTURERS SPECIFICATIONS. BLEND AND STAGGER AS
REQUIRED TO CONCEAL LINE OF NEW ADDITIONS
EXTENT OF EXISTING ROOFLINE
240 x 45 F7 KILN DRIED TREATED PINE
TREADS TO BCA REQUIREMENTS
SELECTED BALUSTRADE, 1000 HIGH, 125
OPENINGS TO BCA CLAUSE 3.9.2
ROOF TRUSSES OVER. ROOF TRUSSES, ROOF BRACING AND TIE DOWNS
TO THE MANUFACTURERS SPECIFICATIONS AND AS1684
DP
MATCH EXISTING
EAVES TO
W4 W5EXISTING
DWELLING
90 x 45 F7 STUD WALLS. WALL FRAMING, BRACING AND TIE-DOWNS TO
THE WALL MANUFACTURERS SPECIFICATIONS AND AS1684DEMOLISH WALLS, ROOF, FLOOR AND FOOTINGS AS REQUIRED
FOR PROPOSED SCOPE OF WORKS SHOWN ON PLANS
Plan Vision Australia12A Whitehaven Drive, Lakelands
W/ (02) 4954 2422 M/ 0414 011 483
Drawn By:
Date:
Sheet:
Client:
Address:
Drawing No:
Scale: @ A3 1 : 100
MWG
Ar03
Additions & Alterations
1 : 100
2
South Elevation
SURVEY NOTE :
Boundary dimensions are assumed only and takenfrom site information, others or owners information.Confirm boundaries before commencement ofconstruction.
Full project specific detailed survey plans havenot been supplied to Plan Vision for planningpurposes. See schedule of specifications fordetails.
ASSUMED W33N WIND SPEED
ASSUMED CLASS 'M'
BUILDERS NOTE:-
* Materials are under no circumstances to beordered direct off Additions Plans. * Materials tobe ordered are only to be ordered from a Buildersor applicable product manufacturers seperate siteconfirmed Materials list. * Additions plans are notintended to be the absolute medium forconstruction information accuracy due to existingbuildings discrepencies and existing buildingshidden characteristics. See schedule ofspecifications for further details.
BUILDERS NOTE
:
Use Dimensions in preference to scale. Site verifyall dimensions before ordering Materials. Footingsinformation shown on these plans may have to bechanged if Builders site excavations reveal non-virgin ground. Consultation of Plan Vision AustraliaPty Ltd would then be necessary to determine therequired changes.
Builder to inspect adequacy of existing footings& piers for proposed scope of works. Replaceexisting footings & sub floor members asnecessary
Revision Schedule
Date DescriptionIssued
by
-
12720
Ground Floor FCL
12720
Ground Floor FCL
10000
Ground Floor
10000
Ground Floor
2720
2720PROPOSED
LIVING
ROOF PITCH TO
MATCH EXISTING
EXISTING GROUNDLINE
SELECTED COLORBOND GUTTERS, FASCIAS AND
DOWNPIPES TO THE MANUFACTURERS SPECIFICATIONS
230 x 230 BRICKWORK PIERS. SEE
FOOTINGS PLAN AND DETAILS
ROOF TRUSSES OVER. ROOF TRUSSES, ROOF BRACING AND TIE DOWNS
TO THE MANUFACTURERS SPECIFICATIONS AND AS1684
SELECTED ALUMINIUM WINDOWS AND DOORS TO THE OWNERS
DETAILS AND MANUFACTURERS SPECIFICATIONSMATCH EXISTING
EAVES TO
90 x 45 F7 STUD WALLS. WALL FRAMING,
BRACING AND TIE-DOWNS TO THE WALL
MANUFACTURERS SPECIFICATIONS AND AS1684 PROPOSED GROUNDLINE
CUT AS REQUIRED FOR MINIMUM 250 SUB-FLOOR
CLEARANCE TO BCA REQUIREMENTS
W3 SD1
12720
Ground Floor FCL
12720
Ground Floor FCL
10000
Ground Floor
10000
Ground Floor
2720
2720
PROPOSED LIVING
PROPOSED
DECK EXISTING KITCHENEXISTING
LIVING
EXISTING
BED
EXISTING GROUNDLINE
ROOF PITCH TO
MATCH EXISTING
SELECTED COLORBOND GUTTERS, FASCIAS AND
DOWNPIPES TO THE MANUFACTURERS SPECIFICATIONS
230 x 230 BRICKWORK PIERS. SEE
FOOTINGS PLAN AND DETAILSSELECTED ALUMINIUM WINDOWS AND DOORS TO THE OWNERS
DETAILS AND MANUFACTURERS SPECIFICATIONS
EXTENT OF EXISTING ROOFLINE
240 x 45 F7 KILN DRIED TREATED PINE
TREADS TO BCA REQUIREMENTS
SELECTED BALUSTRADE, 1000 HIGH, 125
OPENINGS TO BCA CLAUSE 3.9.2
ROOF TRUSSES OVER. ROOF TRUSSES, ROOF BRACING AND TIE DOWNS
TO THE MANUFACTURERS SPECIFICATIONS AND AS1684
90 x 45 F7 STUD WALLS. WALL FRAMING, BRACING AND TIE-DOWNS TO
THE WALL MANUFACTURERS SPECIFICATIONS AND AS1684
W2 W1
PROPOSED GROUNDLINE
MATCH EXISTING
EAVES TO
Plan Vision Australia12A Whitehaven Drive, Lakelands
W/ (02) 4954 2422 M/ 0414 011 483
Drawn By:
Date:
Sheet:
Client:
Address:
Drawing No:
Scale: @ A3 1 : 100
MWG
Ar04
Additions & Alterations
1 : 100
1
Section 1
1 : 100
2
Section 2
SURVEY NOTE :Boundary dimensions are assumed only and takenfrom site information, others or owners information.Confirm boundaries before commencement ofconstruction.
Full project specific detailed survey plans havenot been supplied to Plan Vision for planningpurposes. See schedule of specifications fordetails.
ASSUMED W33N WIND SPEED
ASSUMED CLASS 'M'
BUILDERS NOTE:-
* Materials are under no circumstances to beordered direct off Additions Plans. * Materials tobe ordered are only to be ordered from a Buildersor applicable product manufacturers seperate siteconfirmed Materials list. * Additions plans are notintended to be the absolute medium forconstruction information accuracy due to existingbuildings discrepencies and existing buildingshidden characteristics. See schedule ofspecifications for further details.
BUILDERS NOTE
:
Use Dimensions in preference to scale. Site verifyall dimensions before ordering Materials. Footingsinformation shown on these plans may have to bechanged if Builders site excavations reveal non-virgin ground. Consultation of Plan Vision AustraliaPty Ltd would then be necessary to determine therequired changes.
Builder to inspect adequacy of existing footings& piers for proposed scope of works. Replaceexisting footings & sub floor members asnecessary
Revision Schedule
Date DescriptionIssued
by
-
UP
PF1 PF2PF3
BR1
LB1
LB2BR2
PF2 PF2
PF2 PF2 PF2
PF2 PF2 PF2
PF2 PF2 PF2
PF2 PF2 PF2
PF1
PF1
PF1PF1
PF1 PF2BR1
BR1
BR1
BR1
BR1
BR1
BR1
BR1
BR1
BR1
BR1
BR1
BR1
BR1
BR1
BR1
BR2
BR2
BR2
LB2
LB2
LB2
FJ1
FJ1
FJ1
FJ2 EXISTING DWELLING SUB-FLOOR. OTHERS TO
CONFIRM ADEQUACY OF EXISTING FOOTINGS,
PIERS AND SUB-FLOOR MEMBERS FOR PROPOSED
SCOPE OF WORKS SHOWN ON PLANS. UPGRADE
AS REQUIRED TO AS1684.2 & AS2870.1
500 x 500 x 400 MASS CONCRETE FOOTINGS
FOUNDED 500 DEEP (SEE DETAIL)
LB1
LB1
LB1
PF3
PF3
PF3
PF3
PF3
Bearer
Ledger Bearer
Floor Joist
Bearer
Ledger Bearer
Floor Joist
To Engineers details
To Engineers details
To Engineers details
To Engineers details
To Engineers details
To Engineers details
BR1
LB1
FJ1
BR2
LB2
FJ2
Member Description SizeMember Schedule
90 x 90 H4 kiln dried treated pine or
100 x 100 hardwood post
25MPa concrete
500
400 500
Mass concrete pier to be founded
in firm natural material
Run of timber floor shown indicative only
Ant capping200
500
400
250 min
Mass concrete pad
Note:
All white ant protection to be strictly within the guidelines
of AS3600 and qualified licenced pest control consultant
Run of timber floor shown indicative only
Ant capping
Mass concrete pad
Stud wall over
400
500
200
250 min
Plan Vision Australia12A Whitehaven Drive, Lakelands
W/ (02) 4954 2422 M/ 0414 011 483
Drawn By:
Date:
Sheet:
Client:
Address:
Drawing No:
Scale: @ A3As indicated
MWG
Ar05
Additions & Alterations
Revision Schedule
Date DescriptionIssued
by
1 : 100
1
Footings Plan
SURVEY NOTE :
Boundary dimensions are assumed only and takenfrom site information, others or owners information.Confirm boundaries before commencement ofconstruction.
Full project specific detailed survey plans havenot been supplied to Plan Vision for planningpurposes. See schedule of specifications fordetails.
ASSUMED W33N WIND SPEED
ASSUMED CLASS 'M'
BUILDERS NOTE:-
* Materials are under no circumstances to beordered direct off Additions Plans. * Materials tobe ordered are only to be ordered from a Buildersor applicable product manufacturers seperate siteconfirmed Materials list. * Additions plans are notintended to be the absolute medium forconstruction information accuracy due to existingbuildings discrepencies and existing buildingshidden characteristics. See schedule ofspecifications for further details.
BUILDERS NOTE
:
Use Dimensions in preference to scale. Site verifyall dimensions before ordering Materials. Footingsinformation shown on these plans may have to bechanged if Builders site excavations reveal non-virgin ground. Consultation of Plan Vision AustraliaPty Ltd would then be necessary to determine therequired changes.
Builder to inspect adequacy of existing footings& piers for proposed scope of works. Replaceexisting footings & sub floor members asnecessary
PF1 PAD FOOTING DETAIL
1:20
PF2 PAD FOOTING DETAIL
1:20
PF3 PAD FOOTING DETAIL
1:20
NORTH
-
Plan Vision Australia12A Whitehaven Drive, Lakelands
W/ (02) 4954 2422 M/ 0414 011 483
Drawn By:
Date:
Sheet:
Client:
Address:
Drawing No:
Scale: @ A3 1 : 1
MWG
Ar06
Additions & Alterations
Revision Schedule
Date DescriptionIssued
by
SURVEY NOTE :
Boundary dimensions are assumed only and takenfrom site information, others or owners information.Confirm boundaries before commencement ofconstruction.
Full project specific detailed survey plans havenot been supplied to Plan Vision for planningpurposes. See schedule of specifications fordetails.
ASSUMED W33N WIND SPEED
ASSUMED CLASS 'M'
BUILDERS NOTE:-
* Materials are under no circumstances to beordered direct off Additions Plans. * Materials tobe ordered are only to be ordered from a Buildersor applicable product manufacturers seperate siteconfirmed Materials list. * Additions plans are notintended to be the absolute medium forconstruction information accuracy due to existingbuildings discrepencies and existing buildingshidden characteristics. See schedule ofspecifications for further details.
BUILDERS NOTE
:
Use Dimensions in preference to scale. Site verifyall dimensions before ordering Materials. Footingsinformation shown on these plans may have to bechanged if Builders site excavations reveal non-virgin ground. Consultation of Plan Vision AustraliaPty Ltd would then be necessary to determine therequired changes.
Builder to inspect adequacy of existing footings& piers for proposed scope of works. Replaceexisting footings & sub floor members asnecessary
1 : 1
1
3D View 1
1 : 1
2
3D View 2
-
DN
LOT 20
SECTION E
DP 1570
N E I L S O N S T R E E T
APPRO
XIMATE LOCA
TION OF
EXISTING SEW
ER MAIN
BOUNDARY
BOUNDARY
BOUNDARY
BOUNDARY
EXISTING
DWELLING
PROPOSED
ADDITIONS
PROPOSED DRAINAGE LINES TO STREETKERBAS EXISTING
1200 APPROX
AS EXISTING
2170 APPROX
EXISTING SHED
Sediment Control Notes
Sediment Fence
Geotextile filter fabric
200mm
N.T.S
Direction of flow
500m
m
Timber posts driven
300mm into ground
Undisturbed ground
3.00m max.
Disturbed ground
1. All erosion and sedimentation control measures, including revegetation
and storage of soil and topsoil, shall be implemented to the standards of
the soil conservation of nsw.
2. All drainage works shall be constructed and stabilised as early as possible.
3. Sediment traps shall be constructed around all inlet pits, consisting of
300mm wide x 300mm deep trench.
4. All sediment basins and traps shall be cleaned when the structures are a
60% full of soil materials, including the maintenance period.
5. All disturbed areas shall be revegetated as soon as the relevant works are
completed.
6. Soil and topsoil stockpiles shall be located away from drainage lines and
area where water may concentrate.
7. Filter shall be constructed by stretching a filter fabric (propex or
approved equivalent) between post at 3.0m centres. fabric shall be buried
150mm along its lower edge.
Plan Vision Australia12A Whitehaven Drive, Lakelands
W/ (02) 4954 2422 M/ 0414 011 483
Drawn By:
Date:
Sheet:
Client:
Address:
Drawing No:
Scale: @ A3As indicated
MWG
Ar07
Additions & Alterations
Revision Schedule
Date DescriptionIssued
by
1 : 200
1
Site Plan
SURVEY NOTE :
Boundary dimensions are assumed only and takenfrom site information, others or owners information.Confirm boundaries before commencement ofconstruction.
Full project specific detailed survey plans havenot been supplied to Plan Vision for planningpurposes. See schedule of specifications fordetails.
ASSUMED W33N WIND SPEED
ASSUMED CLASS 'M'
BUILDERS NOTE:-
* Materials are under no circumstances to beordered direct off Additions Plans. * Materials tobe ordered are only to be ordered from a Buildersor applicable product manufacturers seperate siteconfirmed Materials list. * Additions plans are notintended to be the absolute medium forconstruction information accuracy due to existingbuildings discrepencies and existing buildingshidden characteristics. See schedule ofspecifications for further details.
BUILDERS NOTE
:
Use Dimensions in preference to scale. Site verifyall dimensions before ordering Materials. Footingsinformation shown on these plans may have to bechanged if Builders site excavations reveal non-virgin ground. Consultation of Plan Vision AustraliaPty Ltd would then be necessary to determine therequired changes.
Builder to inspect adequacy of existing footings& piers for proposed scope of works. Replaceexisting footings & sub floor members asnecessary
NORTH