DN SELECTED COLORBOND GUTTERS, FASCIAS AND DOWNPIPES TO THE MANUFACTURERS SPECIFICATIONS Ar04 1 Ar04 1 Ar04 2 Ar04 2 SELECTED PLASTERBOARD LININGS FIXED TO THE MANUFACTURERS SPECIFICATIONS & THE SCHEDULE OF SPECIFICATIONS DETAILS SELECTED BALUSTRADE, 1000 HIGH, 125 OPENINGS TO BCA CLAUSE 3.9.2 240 x 45 F7 KILN DRIED TREATED PINE TREADS TO BCA REQUIREMENTS 90 x 90 F7 KILN DRIED TREATED PINE OR 100 x 100 HARDWOOD POSTS TO THE OWNERS DETAILS EXTENT OF EXISTING ROOFLINE SELECTED 15mm AC OR 15mm STRUCTURAL GRADE PLY. WETSEAL TO MANUFACTURERS SPECIFICATIONS, SELECTED TILES OVER FIXED TO THE MANUFACTURERS SPECIFICATIONS NOTE - BRACING AND TIE-DOWN DETAILS TO THE ENGINEERS DETAILS AND AS1684.2 NOTE - : ALL TIMBER TO BE INSTALLED TO THE MANUFACTURERS SPECIFICATIONS Existing Bed Existing Bed Existing Bath Existing Kitchen Existing Living Existing Porch Existing Entry 100 1710 90 6000 PROPOSED LIVING 100 1100 100 5340 100 6740 APPROX (SITE CONFIRM) 7900 W2 W1 W4 W5 SD1 W3 2/770 PROPOSED L'DRY CUP'D 1800 100 6000 PROPOSED DECK B1 OVER B1 OVER B1 OVER SELECTED ALUMINIUM WINDOWS AND DOORS TO THE OWNERS DETAILS AND MANUFACTURERS SPECIFICATIONS SELECTED WEATHERBOARDS, SIMILAR TO EXISTING DWELLING, FIXED TO THE MANUFACTURERS SPECIFICATIONS. BLEND AND STAGGER AS REQUIRED TO CONCEAL LINE OF NEW ADDITIONS DEMOLISH WALLS, ROOF, FLOOR AND FOOTINGS AS REQUIRED FOR PROPOSED SCOPE OF WORKS SHOWN ON PLANS 90 x 45 F7 STUD WALLS. WALL FRAMING, BRACING AND TIE-DOWNS TO THE WALL MANUFACTURERS SPECIFICATIONS AND AS1684 DP DP SELECTED KILN DRIED TREATED PINE OR HARDWOOD DECKING 1800 REMOVE EXISTING WINDOW AS REQUIRED FOR PROPOSED SERVERY OPENING AS SHOWN Beams To Engineers details B1 Member Description Size Member Schedule Plan Vision Australia 12A Whitehaven Drive, Lakelands W/ (02) 4954 2422 M/ 0414 011 483 Drawn By: Date: Sheet: Client: Address: Drawing No: Scale: @ A3 1 : 100 MWG Ar01 Additions & Alterations 1 : 100 1 Ground Floor N OR T H SURVEY NOTE : Boundary dimensions are assumed only and taken from site information, others or owners information. Confirm boundaries before commencement of construction. Full project specific detailed survey plans have not been supplied to Plan Vision for planning purposes. See schedule of specifications for details. ASSUMED W33N WIND SPEED ASSUMED CLASS 'M' BUILDERS NOTE:- * Materials are under no circumstances to be ordered direct off Additions Plans. * Materials to be ordered are only to be ordered from a Builders or applicable product manufacturers seperate site confirmed Materials list. * Additions plans are not intended to be the absolute medium for construction information accuracy due to existing buildings discrepencies and existing buildings hidden characteristics. See schedule of specifications for further details. BUILDERS NOTE : Use Dimensions in preference to scale. Site verify all dimensions before ordering Materials. Footings information shown on these plans may have to be changed if Builders site excavations reveal non- virgin ground. Consultation of Plan Vision Australia Pty Ltd would then be necessary to determine the required changes. Builder to inspect adequacy of existing footings & piers for proposed scope of works. Replace existing footings & sub floor members as necessary Revision Schedule Date Description Issued by Door Schedule Level Mark Width Height Type Ground Floor SD1 1847 2121 ASD Window Schedule Level Mark Widt h Height Type Ground Floor W5 1791 590 ASW Ground Floor W4 1791 590 ASW Ground Floor W3 843 2042 ASW+FIXED Ground Floor W2 1791 590 ASW Ground Floor W1 1791 590 ASW

Embed Size (px)

Transcript of Morgan 1111-4140 (2012-01-10) · 12720 Ground Floor FCL 12720 Ground Floor FCL 10000 Ground Floor...

  • DN

    SELECTED COLORBOND GUTTERS, FASCIAS AND

    DOWNPIPES TO THE MANUFACTURERS SPECIFICATIONS

    Ar041

    Ar041

    Ar042

    Ar042

    SELECTED PLASTERBOARD LININGS FIXED TO THE

    MANUFACTURERS SPECIFICATIONS & THE SCHEDULE OF

    SPECIFICATIONS DETAILS

    SELECTED BALUSTRADE, 1000 HIGH, 125

    OPENINGS TO BCA CLAUSE 3.9.2

    240 x 45 F7 KILN DRIED TREATED PINE

    TREADS TO BCA REQUIREMENTS

    90 x 90 F7 KILN DRIED TREATED PINE OR 100 x 100

    HARDWOOD POSTS TO THE OWNERS DETAILSEXTENT OF EXISTING ROOFLINE

    SELECTED 15mm AC OR 15mm STRUCTURAL GRADE PLY. WETSEAL TO

    MANUFACTURERS SPECIFICATIONS, SELECTED TILES OVER FIXED TO

    THE MANUFACTURERS SPECIFICATIONS

    NOTE - BRACING AND TIE-DOWN DETAILS

    TO THE ENGINEERS DETAILS AND AS1684.2

    NOTE - : ALL TIMBER TO BE INSTALLED TO

    THE MANUFACTURERS SPECIFICATIONS

    Existing

    BedExisting

    BedExisting

    Bath

    Existing

    Kitchen

    Existing

    Living Existing

    Porch

    Existing

    Entry

    100 1710 90 6000

    PROPOSED

    LIVING

    100

    1100

    100

    5340

    100

    6740 APPROX (SITE CONFIRM)

    7900

    W2 W1

    W4 W5

    SD1

    W3

    2/770PROPOSED

    L'DRY CUP'D

    1800 100 6000

    PROPOSED

    DECK

    B1 OVER

    B1 OVER

    B1 OVER

    SELECTED ALUMINIUM WINDOWS AND DOORS TO THE OWNERS

    DETAILS AND MANUFACTURERS SPECIFICATIONS

    SELECTED WEATHERBOARDS, SIMILAR TO EXISTING

    DWELLING, FIXED TO THE MANUFACTURERS

    SPECIFICATIONS. BLEND AND STAGGER AS REQUIRED TO

    CONCEAL LINE OF NEW ADDITIONS

    DEMOLISH WALLS, ROOF, FLOOR AND FOOTINGS AS REQUIRED

    FOR PROPOSED SCOPE OF WORKS SHOWN ON PLANS

    90 x 45 F7 STUD WALLS. WALL FRAMING, BRACING AND TIE-DOWNS TO

    THE WALL MANUFACTURERS SPECIFICATIONS AND AS1684

    DP

    DP

    SELECTED KILN DRIED TREATED PINE OR

    HARDWOOD DECKING

    1800

    REMOVE EXISTING WINDOW AS REQUIRED FOR

    PROPOSED SERVERY OPENING AS SHOWN

    Beams To Engineers detailsB1

    Member Description SizeMember Schedule

    Plan Vision Australia12A Whitehaven Drive, Lakelands

    W/ (02) 4954 2422 M/ 0414 011 483

    Drawn By:

    Date:

    Sheet:

    Client:

    Address:

    Drawing No:

    Scale: @ A3 1 : 100

    MWG

    Ar01

    Additions & Alterations

    1 : 100

    1

    Ground Floor

    NORTH

    SURVEY NOTE :

    Boundary dimensions are assumed only and takenfrom site information, others or owners information.Confirm boundaries before commencement ofconstruction.

    Full project specific detailed survey plans havenot been supplied to Plan Vision for planningpurposes. See schedule of specifications fordetails.

    ASSUMED W33N WIND SPEED

    ASSUMED CLASS 'M'

    BUILDERS NOTE:-

    * Materials are under no circumstances to beordered direct off Additions Plans. * Materials tobe ordered are only to be ordered from a Buildersor applicable product manufacturers seperate siteconfirmed Materials list. * Additions plans are notintended to be the absolute medium forconstruction information accuracy due to existingbuildings discrepencies and existing buildingshidden characteristics. See schedule ofspecifications for further details.

    BUILDERS NOTE

    :

    Use Dimensions in preference to scale. Site verifyall dimensions before ordering Materials. Footingsinformation shown on these plans may have to bechanged if Builders site excavations reveal non-virgin ground. Consultation of Plan Vision AustraliaPty Ltd would then be necessary to determine therequired changes.

    Builder to inspect adequacy of existing footings& piers for proposed scope of works. Replaceexisting footings & sub floor members asnecessary

    Revision Schedule

    Date DescriptionIssued

    by

    Door Schedule

    Level Mark Width Height Type

    Ground Floor SD1 1847 2121 ASD

    Window Schedule

    Level Mark

    Widt

    h Height Type

    Ground Floor W5 1791 590 ASW

    Ground Floor W4 1791 590 ASW

    Ground Floor W3 843 2042 ASW+FIXED

    Ground Floor W2 1791 590 ASW

    Ground Floor W1 1791 590 ASW

  • 12720

    Ground Floor FCL

    12720

    Ground Floor FCL

    10000

    Ground Floor

    10000

    Ground Floor

    2720

    2720

    PROPOSED GROUNDLINE

    SD1 W3

    ROOF PITCH TO

    MATCH EXISTING

    EXISTING GROUNDLINE

    SELECTED COLORBOND GUTTERS, FASCIAS AND

    DOWNPIPES TO THE MANUFACTURERS SPECIFICATIONS

    230 x 230 BRICKWORK PIERS. SEE

    FOOTINGS PLAN AND DETAILS

    SELECTED CONCRETE ROOF TILES TO OWNERS DETAILS

    AND FIXED TO THE MANUFACTURERS SPECIFICATIONS

    90 x 45 F7 STUD WALLS. WALL FRAMING, BRACING AND TIE-DOWNS TO

    THE WALL MANUFACTURERS SPECIFICATIONS AND AS1684

    SELECTED KILN DRIED TREATED PINE OR

    HARDWOOD DECKING

    240 x 45 F7 KILN DRIED TREATED PINE

    TREADS TO BCA REQUIREMENTS

    SELECTED BALUSTRADE, 1000 HIGH, 125

    OPENINGS TO BCA CLAUSE 3.9.2

    90 x 90 F7 KILN DRIED TREATED PINE OR 100 x 100

    HARDWOOD POSTS TO THE OWNERS DETAILS

    ROOF TRUSSES OVER. ROOF TRUSSES, ROOF BRACING AND TIE DOWNS

    TO THE MANUFACTURERS SPECIFICATIONS AND AS1684

    SELECTED ALUMINIUM WINDOWS AND DOORS TO THE OWNERS

    DETAILS AND MANUFACTURERS SPECIFICATIONS

    CUT AS REQUIRED FOR MINIMUM 250 SUB-FLOOR

    CLEARANCE TO BCA REQUIREMENTS

    SELECTED WEATHERBOARDS, SIMILAR TO EXISTING DWELLING, FIXED

    TO THE MANUFACTURERS SPECIFICATIONS

    DPDP

    MATCH EXISTING

    EAVES TO

    12720

    Ground Floor FCL

    12720

    Ground Floor FCL

    10000

    Ground Floor

    10000

    Ground Floor

    2720

    2720

    ROOF PITCH TO

    MATCH EXISTING

    PROPOSED GROUNDLINE

    EXISTING GROUNDLINE

    SELECTED COLORBOND GUTTERS, FASCIAS AND

    DOWNPIPES TO THE MANUFACTURERS SPECIFICATIONS

    CUT AS REQUIRED FOR MINIMUM 250 SUB-FLOOR

    CLEARANCE TO BCA REQUIREMENTS

    230 x 230 BRICKWORK PIERS. SEE

    FOOTINGS PLAN AND DETAILS

    SELECTED CONCRETE ROOF TILES TO OWNERS DETAILS

    AND FIXED TO THE MANUFACTURERS SPECIFICATIONS

    SELECTED ALUMINIUM WINDOWS AND DOORS TO THE OWNERS

    DETAILS AND MANUFACTURERS SPECIFICATIONS

    SELECTED WEATHERBOARDS, SIMILAR TO EXISTING DWELLING, FIXED

    TO THE MANUFACTURERS SPECIFICATIONS. BLEND AND STAGGER AS

    REQUIRED TO CONCEAL LINE OF NEW ADDITIONS

    90 x 45 F7 STUD WALLS. WALL FRAMING, BRACING AND TIE-DOWNS TO

    THE WALL MANUFACTURERS SPECIFICATIONS AND AS1684

    DP

    W1 W2

    EXTENT OF EXISTING ROOFLINE

    EAVES TO

    MATCH EXISTING

    SELECTED KILN DRIED TREATED PINE OR

    HARDWOOD DECKING

    240 x 45 F7 KILN DRIED TREATED PINE

    TREADS TO BCA REQUIREMENTS

    SELECTED BALUSTRADE, 1000 HIGH, 125

    OPENINGS TO BCA CLAUSE 3.9.2

    90 x 90 F7 KILN DRIED TREATED PINE OR 100 x 100

    HARDWOOD POSTS TO THE OWNERS DETAILS

    ROOF TRUSSES OVER. ROOF TRUSSES, ROOF BRACING AND TIE DOWNS

    TO THE MANUFACTURERS SPECIFICATIONS AND AS1684

    EXISTING DWELLING

    Plan Vision Australia12A Whitehaven Drive, Lakelands

    W/ (02) 4954 2422 M/ 0414 011 483

    Drawn By:

    Date:

    Sheet:

    Client:

    Address:

    Drawing No:

    Scale: @ A3 1 : 100

    MWG

    Ar02

    Additions & Alterations

    1 : 100

    1

    West Elevation

    1 : 100

    2

    North Elevation

    SURVEY NOTE :

    Boundary dimensions are assumed only and takenfrom site information, others or owners information.Confirm boundaries before commencement ofconstruction.

    Full project specific detailed survey plans havenot been supplied to Plan Vision for planningpurposes. See schedule of specifications fordetails.

    ASSUMED W33N WIND SPEED

    ASSUMED CLASS 'M'

    BUILDERS NOTE:-

    * Materials are under no circumstances to beordered direct off Additions Plans. * Materials tobe ordered are only to be ordered from a Buildersor applicable product manufacturers seperate siteconfirmed Materials list. * Additions plans are notintended to be the absolute medium forconstruction information accuracy due to existingbuildings discrepencies and existing buildingshidden characteristics. See schedule ofspecifications for further details.

    BUILDERS NOTE

    :

    Use Dimensions in preference to scale. Site verifyall dimensions before ordering Materials. Footingsinformation shown on these plans may have to bechanged if Builders site excavations reveal non-virgin ground. Consultation of Plan Vision AustraliaPty Ltd would then be necessary to determine therequired changes.

    Builder to inspect adequacy of existing footings& piers for proposed scope of works. Replaceexisting footings & sub floor members asnecessary

    Revision Schedule

    Date DescriptionIssued

    by

  • 12720

    Ground Floor FCL

    12720

    Ground Floor FCL

    10000

    Ground Floor

    10000

    Ground Floor

    2720

    2720

    EXISTING GROUNDLINE

    ROOF PITCH TO

    MATCH EXISTING

    SELECTED COLORBOND GUTTERS, FASCIAS AND

    DOWNPIPES TO THE MANUFACTURERS SPECIFICATIONS

    230 x 230 BRICKWORK PIERS. SEE

    FOOTINGS PLAN AND DETAILS

    SELECTED CONCRETE ROOF TILES TO OWNERS DETAILS

    AND FIXED TO THE MANUFACTURERS SPECIFICATIONS

    SELECTED ALUMINIUM WINDOWS AND DOORS TO THE OWNERS

    DETAILS AND MANUFACTURERS SPECIFICATIONS

    SELECTED WEATHERBOARDS, SIMILAR TO EXISTING DWELLING, FIXED

    TO THE MANUFACTURERS SPECIFICATIONS. BLEND AND STAGGER AS

    REQUIRED TO CONCEAL LINE OF NEW ADDITIONS

    EXTENT OF EXISTING ROOFLINE

    240 x 45 F7 KILN DRIED TREATED PINE

    TREADS TO BCA REQUIREMENTS

    SELECTED BALUSTRADE, 1000 HIGH, 125

    OPENINGS TO BCA CLAUSE 3.9.2

    ROOF TRUSSES OVER. ROOF TRUSSES, ROOF BRACING AND TIE DOWNS

    TO THE MANUFACTURERS SPECIFICATIONS AND AS1684

    DP

    MATCH EXISTING

    EAVES TO

    W4 W5EXISTING

    DWELLING

    90 x 45 F7 STUD WALLS. WALL FRAMING, BRACING AND TIE-DOWNS TO

    THE WALL MANUFACTURERS SPECIFICATIONS AND AS1684DEMOLISH WALLS, ROOF, FLOOR AND FOOTINGS AS REQUIRED

    FOR PROPOSED SCOPE OF WORKS SHOWN ON PLANS

    Plan Vision Australia12A Whitehaven Drive, Lakelands

    W/ (02) 4954 2422 M/ 0414 011 483

    Drawn By:

    Date:

    Sheet:

    Client:

    Address:

    Drawing No:

    Scale: @ A3 1 : 100

    MWG

    Ar03

    Additions & Alterations

    1 : 100

    2

    South Elevation

    SURVEY NOTE :

    Boundary dimensions are assumed only and takenfrom site information, others or owners information.Confirm boundaries before commencement ofconstruction.

    Full project specific detailed survey plans havenot been supplied to Plan Vision for planningpurposes. See schedule of specifications fordetails.

    ASSUMED W33N WIND SPEED

    ASSUMED CLASS 'M'

    BUILDERS NOTE:-

    * Materials are under no circumstances to beordered direct off Additions Plans. * Materials tobe ordered are only to be ordered from a Buildersor applicable product manufacturers seperate siteconfirmed Materials list. * Additions plans are notintended to be the absolute medium forconstruction information accuracy due to existingbuildings discrepencies and existing buildingshidden characteristics. See schedule ofspecifications for further details.

    BUILDERS NOTE

    :

    Use Dimensions in preference to scale. Site verifyall dimensions before ordering Materials. Footingsinformation shown on these plans may have to bechanged if Builders site excavations reveal non-virgin ground. Consultation of Plan Vision AustraliaPty Ltd would then be necessary to determine therequired changes.

    Builder to inspect adequacy of existing footings& piers for proposed scope of works. Replaceexisting footings & sub floor members asnecessary

    Revision Schedule

    Date DescriptionIssued

    by

  • 12720

    Ground Floor FCL

    12720

    Ground Floor FCL

    10000

    Ground Floor

    10000

    Ground Floor

    2720

    2720PROPOSED

    LIVING

    ROOF PITCH TO

    MATCH EXISTING

    EXISTING GROUNDLINE

    SELECTED COLORBOND GUTTERS, FASCIAS AND

    DOWNPIPES TO THE MANUFACTURERS SPECIFICATIONS

    230 x 230 BRICKWORK PIERS. SEE

    FOOTINGS PLAN AND DETAILS

    ROOF TRUSSES OVER. ROOF TRUSSES, ROOF BRACING AND TIE DOWNS

    TO THE MANUFACTURERS SPECIFICATIONS AND AS1684

    SELECTED ALUMINIUM WINDOWS AND DOORS TO THE OWNERS

    DETAILS AND MANUFACTURERS SPECIFICATIONSMATCH EXISTING

    EAVES TO

    90 x 45 F7 STUD WALLS. WALL FRAMING,

    BRACING AND TIE-DOWNS TO THE WALL

    MANUFACTURERS SPECIFICATIONS AND AS1684 PROPOSED GROUNDLINE

    CUT AS REQUIRED FOR MINIMUM 250 SUB-FLOOR

    CLEARANCE TO BCA REQUIREMENTS

    W3 SD1

    12720

    Ground Floor FCL

    12720

    Ground Floor FCL

    10000

    Ground Floor

    10000

    Ground Floor

    2720

    2720

    PROPOSED LIVING

    PROPOSED

    DECK EXISTING KITCHENEXISTING

    LIVING

    EXISTING

    BED

    EXISTING GROUNDLINE

    ROOF PITCH TO

    MATCH EXISTING

    SELECTED COLORBOND GUTTERS, FASCIAS AND

    DOWNPIPES TO THE MANUFACTURERS SPECIFICATIONS

    230 x 230 BRICKWORK PIERS. SEE

    FOOTINGS PLAN AND DETAILSSELECTED ALUMINIUM WINDOWS AND DOORS TO THE OWNERS

    DETAILS AND MANUFACTURERS SPECIFICATIONS

    EXTENT OF EXISTING ROOFLINE

    240 x 45 F7 KILN DRIED TREATED PINE

    TREADS TO BCA REQUIREMENTS

    SELECTED BALUSTRADE, 1000 HIGH, 125

    OPENINGS TO BCA CLAUSE 3.9.2

    ROOF TRUSSES OVER. ROOF TRUSSES, ROOF BRACING AND TIE DOWNS

    TO THE MANUFACTURERS SPECIFICATIONS AND AS1684

    90 x 45 F7 STUD WALLS. WALL FRAMING, BRACING AND TIE-DOWNS TO

    THE WALL MANUFACTURERS SPECIFICATIONS AND AS1684

    W2 W1

    PROPOSED GROUNDLINE

    MATCH EXISTING

    EAVES TO

    Plan Vision Australia12A Whitehaven Drive, Lakelands

    W/ (02) 4954 2422 M/ 0414 011 483

    Drawn By:

    Date:

    Sheet:

    Client:

    Address:

    Drawing No:

    Scale: @ A3 1 : 100

    MWG

    Ar04

    Additions & Alterations

    1 : 100

    1

    Section 1

    1 : 100

    2

    Section 2

    SURVEY NOTE :Boundary dimensions are assumed only and takenfrom site information, others or owners information.Confirm boundaries before commencement ofconstruction.

    Full project specific detailed survey plans havenot been supplied to Plan Vision for planningpurposes. See schedule of specifications fordetails.

    ASSUMED W33N WIND SPEED

    ASSUMED CLASS 'M'

    BUILDERS NOTE:-

    * Materials are under no circumstances to beordered direct off Additions Plans. * Materials tobe ordered are only to be ordered from a Buildersor applicable product manufacturers seperate siteconfirmed Materials list. * Additions plans are notintended to be the absolute medium forconstruction information accuracy due to existingbuildings discrepencies and existing buildingshidden characteristics. See schedule ofspecifications for further details.

    BUILDERS NOTE

    :

    Use Dimensions in preference to scale. Site verifyall dimensions before ordering Materials. Footingsinformation shown on these plans may have to bechanged if Builders site excavations reveal non-virgin ground. Consultation of Plan Vision AustraliaPty Ltd would then be necessary to determine therequired changes.

    Builder to inspect adequacy of existing footings& piers for proposed scope of works. Replaceexisting footings & sub floor members asnecessary

    Revision Schedule

    Date DescriptionIssued

    by

  • UP

    PF1 PF2PF3

    BR1

    LB1

    LB2BR2

    PF2 PF2

    PF2 PF2 PF2

    PF2 PF2 PF2

    PF2 PF2 PF2

    PF2 PF2 PF2

    PF1

    PF1

    PF1PF1

    PF1 PF2BR1

    BR1

    BR1

    BR1

    BR1

    BR1

    BR1

    BR1

    BR1

    BR1

    BR1

    BR1

    BR1

    BR1

    BR1

    BR1

    BR2

    BR2

    BR2

    LB2

    LB2

    LB2

    FJ1

    FJ1

    FJ1

    FJ2 EXISTING DWELLING SUB-FLOOR. OTHERS TO

    CONFIRM ADEQUACY OF EXISTING FOOTINGS,

    PIERS AND SUB-FLOOR MEMBERS FOR PROPOSED

    SCOPE OF WORKS SHOWN ON PLANS. UPGRADE

    AS REQUIRED TO AS1684.2 & AS2870.1

    500 x 500 x 400 MASS CONCRETE FOOTINGS

    FOUNDED 500 DEEP (SEE DETAIL)

    LB1

    LB1

    LB1

    PF3

    PF3

    PF3

    PF3

    PF3

    Bearer

    Ledger Bearer

    Floor Joist

    Bearer

    Ledger Bearer

    Floor Joist

    To Engineers details

    To Engineers details

    To Engineers details

    To Engineers details

    To Engineers details

    To Engineers details

    BR1

    LB1

    FJ1

    BR2

    LB2

    FJ2

    Member Description SizeMember Schedule

    90 x 90 H4 kiln dried treated pine or

    100 x 100 hardwood post

    25MPa concrete

    500

    400 500

    Mass concrete pier to be founded

    in firm natural material

    Run of timber floor shown indicative only

    Ant capping200

    500

    400

    250 min

    Mass concrete pad

    Note:

    All white ant protection to be strictly within the guidelines

    of AS3600 and qualified licenced pest control consultant

    Run of timber floor shown indicative only

    Ant capping

    Mass concrete pad

    Stud wall over

    400

    500

    200

    250 min

    Plan Vision Australia12A Whitehaven Drive, Lakelands

    W/ (02) 4954 2422 M/ 0414 011 483

    Drawn By:

    Date:

    Sheet:

    Client:

    Address:

    Drawing No:

    Scale: @ A3As indicated

    MWG

    Ar05

    Additions & Alterations

    Revision Schedule

    Date DescriptionIssued

    by

    1 : 100

    1

    Footings Plan

    SURVEY NOTE :

    Boundary dimensions are assumed only and takenfrom site information, others or owners information.Confirm boundaries before commencement ofconstruction.

    Full project specific detailed survey plans havenot been supplied to Plan Vision for planningpurposes. See schedule of specifications fordetails.

    ASSUMED W33N WIND SPEED

    ASSUMED CLASS 'M'

    BUILDERS NOTE:-

    * Materials are under no circumstances to beordered direct off Additions Plans. * Materials tobe ordered are only to be ordered from a Buildersor applicable product manufacturers seperate siteconfirmed Materials list. * Additions plans are notintended to be the absolute medium forconstruction information accuracy due to existingbuildings discrepencies and existing buildingshidden characteristics. See schedule ofspecifications for further details.

    BUILDERS NOTE

    :

    Use Dimensions in preference to scale. Site verifyall dimensions before ordering Materials. Footingsinformation shown on these plans may have to bechanged if Builders site excavations reveal non-virgin ground. Consultation of Plan Vision AustraliaPty Ltd would then be necessary to determine therequired changes.

    Builder to inspect adequacy of existing footings& piers for proposed scope of works. Replaceexisting footings & sub floor members asnecessary

    PF1 PAD FOOTING DETAIL

    1:20

    PF2 PAD FOOTING DETAIL

    1:20

    PF3 PAD FOOTING DETAIL

    1:20

    NORTH

  • Plan Vision Australia12A Whitehaven Drive, Lakelands

    W/ (02) 4954 2422 M/ 0414 011 483

    Drawn By:

    Date:

    Sheet:

    Client:

    Address:

    Drawing No:

    Scale: @ A3 1 : 1

    MWG

    Ar06

    Additions & Alterations

    Revision Schedule

    Date DescriptionIssued

    by

    SURVEY NOTE :

    Boundary dimensions are assumed only and takenfrom site information, others or owners information.Confirm boundaries before commencement ofconstruction.

    Full project specific detailed survey plans havenot been supplied to Plan Vision for planningpurposes. See schedule of specifications fordetails.

    ASSUMED W33N WIND SPEED

    ASSUMED CLASS 'M'

    BUILDERS NOTE:-

    * Materials are under no circumstances to beordered direct off Additions Plans. * Materials tobe ordered are only to be ordered from a Buildersor applicable product manufacturers seperate siteconfirmed Materials list. * Additions plans are notintended to be the absolute medium forconstruction information accuracy due to existingbuildings discrepencies and existing buildingshidden characteristics. See schedule ofspecifications for further details.

    BUILDERS NOTE

    :

    Use Dimensions in preference to scale. Site verifyall dimensions before ordering Materials. Footingsinformation shown on these plans may have to bechanged if Builders site excavations reveal non-virgin ground. Consultation of Plan Vision AustraliaPty Ltd would then be necessary to determine therequired changes.

    Builder to inspect adequacy of existing footings& piers for proposed scope of works. Replaceexisting footings & sub floor members asnecessary

    1 : 1

    1

    3D View 1

    1 : 1

    2

    3D View 2

  • DN

    LOT 20

    SECTION E

    DP 1570

    N E I L S O N S T R E E T

    APPRO

    XIMATE LOCA

    TION OF

    EXISTING SEW

    ER MAIN

    BOUNDARY

    BOUNDARY

    BOUNDARY

    BOUNDARY

    EXISTING

    DWELLING

    PROPOSED

    ADDITIONS

    PROPOSED DRAINAGE LINES TO STREETKERBAS EXISTING

    1200 APPROX

    AS EXISTING

    2170 APPROX

    EXISTING SHED

    Sediment Control Notes

    Sediment Fence

    Geotextile filter fabric

    200mm

    N.T.S

    Direction of flow

    500m

    m

    Timber posts driven

    300mm into ground

    Undisturbed ground

    3.00m max.

    Disturbed ground

    1. All erosion and sedimentation control measures, including revegetation

    and storage of soil and topsoil, shall be implemented to the standards of

    the soil conservation of nsw.

    2. All drainage works shall be constructed and stabilised as early as possible.

    3. Sediment traps shall be constructed around all inlet pits, consisting of

    300mm wide x 300mm deep trench.

    4. All sediment basins and traps shall be cleaned when the structures are a

    60% full of soil materials, including the maintenance period.

    5. All disturbed areas shall be revegetated as soon as the relevant works are

    completed.

    6. Soil and topsoil stockpiles shall be located away from drainage lines and

    area where water may concentrate.

    7. Filter shall be constructed by stretching a filter fabric (propex or

    approved equivalent) between post at 3.0m centres. fabric shall be buried

    150mm along its lower edge.

    Plan Vision Australia12A Whitehaven Drive, Lakelands

    W/ (02) 4954 2422 M/ 0414 011 483

    Drawn By:

    Date:

    Sheet:

    Client:

    Address:

    Drawing No:

    Scale: @ A3As indicated

    MWG

    Ar07

    Additions & Alterations

    Revision Schedule

    Date DescriptionIssued

    by

    1 : 200

    1

    Site Plan

    SURVEY NOTE :

    Boundary dimensions are assumed only and takenfrom site information, others or owners information.Confirm boundaries before commencement ofconstruction.

    Full project specific detailed survey plans havenot been supplied to Plan Vision for planningpurposes. See schedule of specifications fordetails.

    ASSUMED W33N WIND SPEED

    ASSUMED CLASS 'M'

    BUILDERS NOTE:-

    * Materials are under no circumstances to beordered direct off Additions Plans. * Materials tobe ordered are only to be ordered from a Buildersor applicable product manufacturers seperate siteconfirmed Materials list. * Additions plans are notintended to be the absolute medium forconstruction information accuracy due to existingbuildings discrepencies and existing buildingshidden characteristics. See schedule ofspecifications for further details.

    BUILDERS NOTE

    :

    Use Dimensions in preference to scale. Site verifyall dimensions before ordering Materials. Footingsinformation shown on these plans may have to bechanged if Builders site excavations reveal non-virgin ground. Consultation of Plan Vision AustraliaPty Ltd would then be necessary to determine therequired changes.

    Builder to inspect adequacy of existing footings& piers for proposed scope of works. Replaceexisting footings & sub floor members asnecessary

    NORTH