© Packet Power 2015

About Packet Power

Founded in 2008

Based in Minneapolis, MN

Global partner network

Customers on 6 continents

Over 30,000 monitoring units deployed

© Packet Power 2015 3

© Packet Power 2015

Our goal

Make it easy and affordable to capture energy information everywhere it is of value

© Packet Power 2015 4

© Packet Power 2015

Create a monitoring platform that is:

Cost-effective

Flexible

Complete

Secure

Robust

Simple

© Packet Power 2015 11

© Packet Power 2015

We Built It Secure, purpose-built wireless mesh network

860-900MHz and 2.4GHz

Power monitoring from 10 to 3000+ amps

plug and play smart power cables plus busway, panel, PDU and whip

Flexible environmental monitoring

temperature, RH and pressure

Simple software – cloud or local

open – full SNMP and Modbus support

Simple Robust Secure Complete Flexible Cost-effective

© Packet Power 2015 12

© Packet Power 2015

Simple network connectivity

Gateways access data from up to 150 monitors each

add gateways to grow

standard, SNMP and Modbus models

Use Hubs to connect SNMP or Modbus monitors to EMX

DCIMBMS

EMX

© Packet Power 2015 13

© Packet Power 2015

Facility-wide power monitoring

Device, branch circuit and mains metering

AC and DC

Wide range of form factors

New build and retrofit

Primary uses cost allocation

operations management

energy efficiency

© Packet Power 2015 14

© Packet Power 2015

Power monitoring products

Smart power cables 10 to 100A Single- and three-phase

Panel monitoring panel infeed circuits or selective branch circuits switchgear, MDPs, RPPs, floor PDUs

Current-only monitoring 48V and 380V DC monitoring Integrated power strips, busways and whips

© Packet Power 2015 17

© Packet Power 2015

Wireless DC Monitoring Offerings Three related offerings

200-380V HVDC for data centers

48V for telecom / cable / wireless

5-24V for low voltage monitoring

Report V, A, W, Wh at ± 1% accuracy

Net metering capable

Use Packet Power’s wireless mesh network

© Packet Power 2015 18

© Packet Power 2015

48V DC Monitoring

Wireless power monitors Integrated 35 and 65 amp CTs External 20 – 3000A solid- or split-core CTs

Small size – 35 x 35 mm base Powered directly from 35 to 60V source ± 1% accuracy at 10-100% of range DIN rail, adhesive pad, cable tie or screw mount

© Packet Power 2015 19

© Packet Power 2015

High Voltage Direct Current Monitoring

Full power monitoring for DC systems 100 to 380 Volts

20 to 3000 Amps

Wireless data transmission using secure Packet Power mesh network

Suitable for use in busways and other enclosed environments

© Packet Power 2015 20

HVDC Components

Voltage and current sensors Wireless communication to display unit

Integrated or external CTs

Compact 35 x 35 mm base

DIN rail mount option

Display Mounts easily in 1” NPT knockout

Forms wireless connection to other displays and Ethernet Gateway

Display and CTs powered by 5V DC power supply

© Packet Power 2015 22

© Packet Power 2015

Initial DC Product Models

Product Number CT Type AmperageCT Inside Diameter (mm)

DC03-T00S Solid Core Integrated 35 8.5

DC06-T00S Solid Core Integrated 65 8.5

DC0E-T100 Split Core External 100 21

DC0E-T200 Split Core External 200 21

DC0E-T300 Split Core External 300 35

DC0E-T400 Split Core External 400 35

DC0E-T500 Split Core External 500 35

DC0E-T800 Split Core External 800 50

DC0E-T1X0 Split Core External 1000 84x22

DC0E-T2X0 Split Core External 2000 100x42

48 VDC Current / Power Monitors (20-65 V)

Product Number CT Type AmperageCT Inside Diameter (mm)

DC03-000S Solid Core Integrated 35 8.5

DC06-000S Solid Core Integrated 65 8.5

DC0E-0100 Split Core External 100 21

DC0E-0200 Split Core External 200 21

DC0E-0300 Split Core External 300 35

DC0E-0400 Split Core External 400 35

DC0E-0500 Split Core External 500 35

DC0E-0800 Split Core External 800 50

DC0E-01X0 Split Core External 1000 84x22

DC0E-02X0 Split Core External 2000 100x42

24 VDC Current / Power Monitors (5-36 V)

Example HVDC Models

DG06-002S includes: 1 x Display2 x Integrated 65A CT Current Monitors1 x 380 to 5V DC Power Supply1 x Harness Kit

Product Number Current VoltageDG30-V01S 1 x 300A Solid Core External Yes

DG06-002S 2 x 65A Solid Core Shared

DG03-001S 1 35A Solid Core Shared

© Packet Power 2015 25

© Packet Power 2015

Flexible environmental monitoring E306 - 1 to 6 temperature points per unit

AC power or PoE with splitter

E312 - 1 to 12 temperature points per unit 2 x AA battery or optional AC power

Temperature probe choices individual probes - 1 to 15 meters

probe assemblies - 1, 2, 3, 4 or 6 probes / cabinet

Option for relative humidity and differential pressure

© Packet Power 2015 26

© Packet Power 2015

Instant information from EMX

Get immediate value

data automatically flows on install

no external consultants needed

customize when and as you see fit

Real-time alerts

Flexible reporting

Cloud service or local software

Works with non-Packet Power monitors

© Packet Power 2015 33

© Packet Power 2015

Proven worldwide

© Packet Power 2015 34

© Packet Power 2015

SimpleRobustSecureCompleteFlexibleCost-effective

Easy to install Easy to get the data Easy to manage

configures itself adapts to changes grows easily optimizes performance

Designed for tough conditions Contends with a lot of metal and noise

long wavelengths ~ 900 MHz multiple paths small transmissions dynamic routing

Works for big and small installs Hardware

low price per unit

no need to run cables or remove existing devices use your existing software

Software low total cost

Instant access to information no need for expensive consultants works with existing monitoring units

Shortest time to value

Separate from primary networks

Limited, purpose-built protocol

Wireless / wired separation

Data is pulled on wired network

Sub-divide wireless networks

Encryption

Monitor where you want

servers, branch circuits, PDUs, panels, switchgear

low, medium and high-density tracking

Mix and match as you see fit

Grow easily over time

Fully open and vendor neutral

works on any vendors hardware

send data from our monitors to other software

use data from other monitors in our software

Power monitoring

Environmental monitoring

Software

Sophisticated monitoring made easy

Monitoring Made Easy

Thank you

Distribué en France par

Distributeur Européen exclusifDaxten France