Moeller GmbHGB Leistungsschalter

The new line of circuit breaker IZM

ILS

-P /

W. W

agne

r Ju

ly 2

003,

01

IZM

Bac

is D

evic

es, p

age

1P

rote

ctiv

e no

te to

rul

e D

IN IS

O 1

6016

is to

be

cons

ider

ed

Electronic overcurrent releases

Page 2: Moeller GmbH GB Leistungsschalter Protective note to rule DIN ISO 16016 is to be considered The new line of circuit breaker IZM ILS-P / W. Wagner July.

Moeller GmbHGB Leistungsschalter

The new line of circuit breaker IZM

ILS

-P /

W. W

agne

r Ju

ly 2

003,

01

IZM

Bac

is D

evic

es, p

age

2P

rote

ctiv

e no

te to

rul

e D

IN IS

O 1

6016

is to

be

cons

ider

ed

Electronic overcurrent releases

First I want to present an overview of the electronic overcurrent releases (short form: trip units) with more

details.

Because this is the most important device of the IZM circuit breaker.

Page 3: Moeller GmbH GB Leistungsschalter Protective note to rule DIN ISO 16016 is to be considered The new line of circuit breaker IZM ILS-P / W. Wagner July.

Moeller GmbHGB Leistungsschalter

The new line of circuit breaker IZM

ILS

-P /

W. W

agne

r Ju

ly 2

003,

01

IZM

Bac

is D

evic

es, p

age

3P

rote

ctiv

e no

te to

rul

e D

IN IS

O 1

6016

is to

be

cons

ider

ed

Overview of the electronic overcurrent releases

Which features are the same for all types?

Additional features for type V, U, R and D

Special features for type U, R and D

Graphical display

How to do the settings?

Characteristics

Electronic overcurrent releases

Page 4: Moeller GmbH GB Leistungsschalter Protective note to rule DIN ISO 16016 is to be considered The new line of circuit breaker IZM ILS-P / W. Wagner July.

Moeller GmbHGB Leistungsschalter

The new line of circuit breaker IZM

ILS

-P /

W. W

agne

r Ju

ly 2

003,

01

IZM

Bac

is D

evic

es, p

age

4P

rote

ctiv

e no

te to

rul

e D

IN IS

O 1

6016

is to

be

cons

ider

ed

Trip units: Types of electronic overcurrent releases- overview -

XZMD

XZMR

L-I L-S-I (-N-G)L-S-I-N-GL-S-I L-S-I (-N-G) L-S-I (-N-G)

XZMV

XZMA XZMV XZMV+XT XZMU (+XT) XZMR (+XT) XZMD (+XT)

Earth fault protection ‚XT‘ is optional and for type ‚U‘, ‚R‘ and ‚D‘ even modular for retrofitting.

XZMV XZMUXZMA

Page 5: Moeller GmbH GB Leistungsschalter Protective note to rule DIN ISO 16016 is to be considered The new line of circuit breaker IZM ILS-P / W. Wagner July.

Moeller GmbHGB Leistungsschalter

The new line of circuit breaker IZM

ILS

-P /

W. W

agne

r Ju

ly 2

003,

01

IZM

Bac

is D

evic

es, p

age

5P

rote

ctiv

e no

te to

rul

e D

IN IS

O 1

6016

is to

be

cons

ider

ed

XZMA Release for power distribution system protection

XZMV Release for selective (discriminative) protection

XZMU Release for universal protection

XZMR Digital release, for external parameterization only

XZMD Digital release

Circuit breaker with trip units type ‘U’, ‘R’ and ‘D’ are already equipped with the internal system bus

Trip units: Types of electronic overcurrent releases

Page 6: Moeller GmbH GB Leistungsschalter Protective note to rule DIN ISO 16016 is to be considered The new line of circuit breaker IZM ILS-P / W. Wagner July.

Moeller GmbHGB Leistungsschalter

The new line of circuit breaker IZM

ILS

-P /

W. W

agne

r Ju

ly 2

003,

01

IZM

Bac

is D

evic

es, p

age

6P

rote

ctiv

e no

te to

rul

e D

IN IS

O 1

6016

is to

be

cons

ider

ed

IZM trip units:

L Inverse time-delay overLoad range A, V, V+XT, U, R, D

S Short-time delay short-circuit tripping V, V+XT, U, R, D

I Instantaneous short-circuit tripping A, V, V+XT, U, R, D

N Neutral conductor overload tripping V+XT, U, R, D

G Earth fault tripping (Ground fault) V+XT, U+XT(A), R+XT(A), D+XT(A)+XT = earth-fault release

additional equipment

Trip units: The different protective ranges

Page 7: Moeller GmbH GB Leistungsschalter Protective note to rule DIN ISO 16016 is to be considered The new line of circuit breaker IZM ILS-P / W. Wagner July.

Moeller GmbHGB Leistungsschalter

The new line of circuit breaker IZM

ILS

-P /

W. W

agne

r Ju

ly 2

003,

01

IZM

Bac

is D

evic

es, p

age

7P

rote

ctiv

e no

te to

rul

e D

IN IS

O 1

6016

is to

be

cons

ider

ed

XZMA

Trip units: Same features for all types

Mechanical reset:

• indicates a tripping because of overload, short circuit or earth fault

• press tripped indicator until it latches for reset of the mechanical reclosing lockout and XHIA

• optional: automatic reset XFR

• optional: safety lock for the tripped indicator prohibits accidental resetting of the mechanical reclosing lockout NEWNEW

NEWNEW

Page 8: Moeller GmbH GB Leistungsschalter Protective note to rule DIN ISO 16016 is to be considered The new line of circuit breaker IZM ILS-P / W. Wagner July.

Moeller GmbHGB Leistungsschalter

The new line of circuit breaker IZM

ILS

-P /

W. W

agne

r Ju

ly 2

003,

01

IZM

Bac

is D

evic

es, p

age

8P

rote

ctiv

e no

te to

rul

e D

IN IS

O 1

6016

is to

be

cons

ider

ed

XZMA

LED indicators

• ACTIVE-LED (flashing green light): overcurrent release is activated = enough supply from the internal current transformers or from an external source (possible for type U, R, D)

• ALARM-LED (continuously yellow light): overload alarm, is displayed if the load is higher than the current setting Ir

NEWNEW

Trip units: Same features for all types

Page 9: Moeller GmbH GB Leistungsschalter Protective note to rule DIN ISO 16016 is to be considered The new line of circuit breaker IZM ILS-P / W. Wagner July.

Moeller GmbHGB Leistungsschalter

The new line of circuit breaker IZM

ILS

-P /

W. W

agne

r Ju

ly 2

003,

01

IZM

Bac

is D

evic

es, p

age

9P

rote

ctiv

e no

te to

rul

e D

IN IS

O 1

6016

is to

be

cons

ider

ed

XZMA

Rating PlugIn = 3200 A ERROR

Error will be displayed with:

• Microprozessor error• Internal system bus error• Memory test error • Temperature sensor• Setting error• Rating Plug is missing or defective

NEWNEW

Trip units: Same features for all types

Page 10: Moeller GmbH GB Leistungsschalter Protective note to rule DIN ISO 16016 is to be considered The new line of circuit breaker IZM ILS-P / W. Wagner July.

Moeller GmbHGB Leistungsschalter

The new line of circuit breaker IZM

ILS

-P /

W. W

agne

r Ju

ly 2

003,

01

IZM

Bac

is D

evic

es, p

age

10P

rote

ctiv

e no

te to

rul

e D

IN IS

O 1

6016

is to

be

cons

ider

ed

XZMA

Sealing eyelet

for the optional sealing cover XHB(G)

Trip units: Same features for all types

Page 11: Moeller GmbH GB Leistungsschalter Protective note to rule DIN ISO 16016 is to be considered The new line of circuit breaker IZM ILS-P / W. Wagner July.

Moeller GmbHGB Leistungsschalter

The new line of circuit breaker IZM

ILS

-P /

W. W

agne

r Ju

ly 2

003,

01

IZM

Bac

is D

evic

es, p

age

11P

rote

ctiv

e no

te to

rul

e D

IN IS

O 1

6016

is to

be

cons

ider

ed

XZMA

Test socket

• for connection to the test device

• also used for connection to XEM-PG(E) with types U, R, D

(1) LED for operating voltage indication

(2) Control buttons

(3) 6 LEDs to show test result

Trip units: Same features for all types

Page 12: Moeller GmbH GB Leistungsschalter Protective note to rule DIN ISO 16016 is to be considered The new line of circuit breaker IZM ILS-P / W. Wagner July.

Moeller GmbHGB Leistungsschalter

The new line of circuit breaker IZM

ILS

-P /

W. W

agne

r Ju

ly 2

003,

01

IZM

Bac

is D

evic

es, p

age

12P

rote

ctiv

e no

te to

rul

e D

IN IS

O 1

6016

is to

be

cons

ider

ed

Trip units: Additional features for type V, U, R and D

XZMV

Rating PlugIn = 3200 A

T. U.

ERROR

Rating Plug:

• plug in version / changeable• responsible for rated current In of IZM • range of rated current: 250A-6300A

Take into account:

All adjustments are based on the rated current In!

NEWNEW

Page 13: Moeller GmbH GB Leistungsschalter Protective note to rule DIN ISO 16016 is to be considered The new line of circuit breaker IZM ILS-P / W. Wagner July.

Moeller GmbHGB Leistungsschalter

The new line of circuit breaker IZM

ILS

-P /

W. W

agne

r Ju

ly 2

003,

01

IZM

Bac

is D

evic

es, p

age

13P

rote

ctiv

e no

te to

rul

e D

IN IS

O 1

6016

is to

be

cons

ider

ed

XZMV

Differentiated trip indication

Indication of the trip reason:- overload (phases or N-conductor)- short circuit (delayed trip)- short circuit (instantaneous trip) - ground fault

Indicator is illuminated, if protocol-button is pressed

standard now

standard now

Trip units: Additional features for type V, U, R and D

Page 14: Moeller GmbH GB Leistungsschalter Protective note to rule DIN ISO 16016 is to be considered The new line of circuit breaker IZM ILS-P / W. Wagner July.

Moeller GmbHGB Leistungsschalter

The new line of circuit breaker IZM

ILS

-P /

W. W

agne

r Ju

ly 2

003,

01

IZM

Bac

is D

evic

es, p

age

14P

rote

ctiv

e no

te to

rul

e D

IN IS

O 1

6016

is to

be

cons

ider

ed

XZMV Selective protection

Delayed short circuit release

Isd = 1.25 ... 12 x In (up to 0.8 x Icw for type R, D)

tsd = 0; 20 (M); 100 ... 400 ms for type V with OFF-setting for type U, R, D with tsd up to 4000 ms for type R, D (at reduced Isd)

M: special adjustment for motor protection with single phase sensitivity

Trip units: Additional features for type V, U, R and D

NEWNEW

Page 15: Moeller GmbH GB Leistungsschalter Protective note to rule DIN ISO 16016 is to be considered The new line of circuit breaker IZM ILS-P / W. Wagner July.

Moeller GmbHGB Leistungsschalter

The new line of circuit breaker IZM

ILS

-P /

W. W

agne

r Ju

ly 2

003,

01

IZM

Bac

is D

evic

es, p

age

15P

rote

ctiv

e no

te to

rul

e D

IN IS

O 1

6016

is to

be

cons

ider

ed

XZMV

Test buttons

Test: Internal self test with or without tripping

Protocol: Finding the cause of trip

Clear: - Interrupt the test - clear memory (cause of trip)

standard now

standard now

Trip units: Additional features for type V, U, R and D

TEST PROTOCOL CLEAR

Page 16: Moeller GmbH GB Leistungsschalter Protective note to rule DIN ISO 16016 is to be considered The new line of circuit breaker IZM ILS-P / W. Wagner July.

Moeller GmbHGB Leistungsschalter

The new line of circuit breaker IZM

ILS

-P /

W. W

agne

r Ju

ly 2

003,

01

IZM

Bac

is D

evic

es, p

age

16P

rote

ctiv

e no

te to

rul

e D

IN IS

O 1

6016

is to

be

cons

ider

ed

XZMV

Trip units: Additional features for type V, U, R and D

Earth fault protection

XZMV+XT

• modificated trip unit• only available as plus type (not for retrofitting)

A B C D E

The current setting is depending on the frame size of the breaker. As reference you‘ll find a small glew lable on the front panel.

Page 17: Moeller GmbH GB Leistungsschalter Protective note to rule DIN ISO 16016 is to be considered The new line of circuit breaker IZM ILS-P / W. Wagner July.

Moeller GmbHGB Leistungsschalter

The new line of circuit breaker IZM

ILS

-P /

W. W

agne

r Ju

ly 2

003,

01

IZM

Bac

is D

evic

es, p

age

17P

rote

ctiv

e no

te to

rul

e D

IN IS

O 1

6016

is to

be

cons

ider

ed

Trip units: Special features for type U, R and D

Modular earth fault protection

• modular and suitable for retrofitting• available as a single- and plus-type• two different modifications:

• only alarm function• with alarm and trip function

XZMU XZMR

XZMD

Page 18: Moeller GmbH GB Leistungsschalter Protective note to rule DIN ISO 16016 is to be considered The new line of circuit breaker IZM ILS-P / W. Wagner July.

Moeller GmbHGB Leistungsschalter

The new line of circuit breaker IZM

ILS

-P /

W. W

agne

r Ju

ly 2

003,

01

IZM

Bac

is D

evic

es, p

age

18P

rote

ctiv

e no

te to

rul

e D

IN IS

O 1

6016

is to

be

cons

ider

ed

Trip units: Special features for type U

Optional 4-line display for universal trip unit:

LCD-display, very good readable because mounted with an angle of 15°, can be turned in vertical direction by 180°.

Installed with downward inclination

Installed with upward inclination

NEWNEW

Page 19: Moeller GmbH GB Leistungsschalter Protective note to rule DIN ISO 16016 is to be considered The new line of circuit breaker IZM ILS-P / W. Wagner July.

Moeller GmbHGB Leistungsschalter

The new line of circuit breaker IZM

ILS

-P /

W. W

agne

r Ju

ly 2

003,

01

IZM

Bac

is D

evic

es, p

age

19P

rote

ctiv

e no

te to

rul

e D

IN IS

O 1

6016

is to

be

cons

ider

ed

XZMU

Trip units: Special features for type U, R, D

Standard DIP switches

1. Thermal memory - can be switched on/off

2. Neutral protection:- can be switched on/off- adjustable to 50% or 100%

protection

3. Changing from I²t to I4t- adjustment of the characteristic in the overload range (for improved selectivity to fuses in the middle voltage)

NEWNEW

Page 20: Moeller GmbH GB Leistungsschalter Protective note to rule DIN ISO 16016 is to be considered The new line of circuit breaker IZM ILS-P / W. Wagner July.

Moeller GmbHGB Leistungsschalter

The new line of circuit breaker IZM

ILS

-P /

W. W

agne

r Ju

ly 2

003,

01

IZM

Bac

is D

evic

es, p

age

20P

rote

ctiv

e no

te to

rul

e D

IN IS

O 1

6016

is to

be

cons

ider

ed

XZMU

Trip units: Special features for type U, R, D

Modification of the characteristic

Overload range:

Standard: I²t = const.

modification: I4t = const.

for improved selectivity to (middle voltage) fuses

Short time delayed short circuit range:

standard: Isd = const.

modification: I²tsd = const.

(by using „I²tsd“-setting instead of „tsd“-setting)

for improved selectivity to

downstream fuses

NEWNEW

Page 21: Moeller GmbH GB Leistungsschalter Protective note to rule DIN ISO 16016 is to be considered The new line of circuit breaker IZM ILS-P / W. Wagner July.

Moeller GmbHGB Leistungsschalter

The new line of circuit breaker IZM

ILS

-P /

W. W

agne

r Ju

ly 2

003,

01

IZM

Bac

is D

evic

es, p

age

21P

rote

ctiv

e no

te to

rul

e D

IN IS

O 1

6016

is to

be

cons

ider

ed

XZMU

Trip units: Special features for type U, R, D

Instantaneous short circuit release

Adjustment: Ii = 1.5 ... 12 In

Ii = MAX Attention: MAX = 0,8 x Icw

Ii = OFF Attention: OFF: Ics = Icw

Ics = rated service short-circuit breaking capacity

Icw = rated short-time withstand current

Page 22: Moeller GmbH GB Leistungsschalter Protective note to rule DIN ISO 16016 is to be considered The new line of circuit breaker IZM ILS-P / W. Wagner July.

Moeller GmbHGB Leistungsschalter

The new line of circuit breaker IZM

ILS

-P /

W. W

agne

r Ju

ly 2

003,

01

IZM

Bac

is D

evic

es, p

age

22P

rote

ctiv

e no

te to

rul

e D

IN IS

O 1

6016

is to

be

cons

ider

ed

XZMU

Trip units: Special features for type U, R, D

Instantaneous short circuit releaseCalculating MAX and OFF

Example: IZMH2-U1600

- Ics= 100 kA /440VAC- Icw= 85 kA/ 0,5s

=> MAX = 0.8 x Icw= 68 kA

=> OFF = Ics= Icw= 85 kA/440VAC

Page 23: Moeller GmbH GB Leistungsschalter Protective note to rule DIN ISO 16016 is to be considered The new line of circuit breaker IZM ILS-P / W. Wagner July.

Moeller GmbHGB Leistungsschalter

The new line of circuit breaker IZM

ILS

-P /

W. W

agne

r Ju

ly 2

003,

01

IZM

Bac

is D

evic

es, p

age

23P

rote

ctiv

e no

te to

rul

e D

IN IS

O 1

6016

is to

be

cons

ider

ed

XZMR

Trip units: Special features for digital types R and D

• higher settings possible: e.g. - tsd up to 4 s - Isd up to 0.8 x Icw - 200% protection for neutral conductor

• adjustment of settings in smaller steps possible

• grahic display for type D (standard)

Page 24: Moeller GmbH GB Leistungsschalter Protective note to rule DIN ISO 16016 is to be considered The new line of circuit breaker IZM ILS-P / W. Wagner July.

Moeller GmbHGB Leistungsschalter

The new line of circuit breaker IZM

ILS

-P /

W. W

agne

r Ju

ly 2

003,

01

IZM

Bac

is D

evic

es, p

age

24P

rote

ctiv

e no

te to

rul

e D

IN IS

O 1

6016

is to

be

cons

ider

ed

Trip units: Digital overcurrent release XZMD

XZMD

Grafic LCD • enables a text output with 8 lines or

• the graphical representation of characteristics.

• it is used both to display data and to parameterise the overcurrent release as well as the metering function.

• the display is operated through the operation keys

Page 25: Moeller GmbH GB Leistungsschalter Protective note to rule DIN ISO 16016 is to be considered The new line of circuit breaker IZM ILS-P / W. Wagner July.

Moeller GmbHGB Leistungsschalter

The new line of circuit breaker IZM

ILS

-P /

W. W

agne

r Ju

ly 2

003,

01

IZM

Bac

is D

evic

es, p

age

25P

rote

ctiv

e no

te to

rul

e D

IN IS

O 1

6016

is to

be

cons

ider

ed

Trip units: Digital overcurrent release XZMD

Grafic LCD: Display design

(1) Menu title

(2) 8-line alphanumeric display or graphical representation

(3) Status line

Page 26: Moeller GmbH GB Leistungsschalter Protective note to rule DIN ISO 16016 is to be considered The new line of circuit breaker IZM ILS-P / W. Wagner July.

Moeller GmbHGB Leistungsschalter

The new line of circuit breaker IZM

ILS

-P /

W. W

agne

r Ju

ly 2

003,

01

IZM

Bac

is D

evic

es, p

age

26P

rote

ctiv

e no

te to

rul

e D

IN IS

O 1

6016

is to

be

cons

ider

ed

Trip units: Digital overcurrent release XZMD

Grafic LCD: Status line

(1) Access with password only

(2) Maintenance required

(3) Parameter set adjusted for protection functions

(4) Edit feature

(5) Adjusted trigger

(6) Possibilities of action

Page 27: Moeller GmbH GB Leistungsschalter Protective note to rule DIN ISO 16016 is to be considered The new line of circuit breaker IZM ILS-P / W. Wagner July.

Moeller GmbHGB Leistungsschalter

The new line of circuit breaker IZM

ILS

-P /

W. W

agne

r Ju

ly 2

003,

01

IZM

Bac

is D

evic

es, p

age

27P

rote

ctiv

e no

te to

rul

e D

IN IS

O 1

6016

is to

be

cons

ider

ed

Trip units: Digital overcurrent release XZMD

Grafic LCD: Navigation in the menu structure

Page 28: Moeller GmbH GB Leistungsschalter Protective note to rule DIN ISO 16016 is to be considered The new line of circuit breaker IZM ILS-P / W. Wagner July.

Moeller GmbHGB Leistungsschalter

The new line of circuit breaker IZM

ILS

-P /

W. W

agne

r Ju

ly 2

003,

01

IZM

Bac

is D

evic

es, p

age

28P

rote

ctiv

e no

te to

rul

e D

IN IS

O 1

6016

is to

be

cons

ider

ed

Trip units: Digital overcurrent release XZMDGrafic LCD is displaying both: numerical values and graphical form

(1) Lowest measured value

(2) Present measured value

(3) Highest measured value

(4) 100% of the measured parameter

(5) Width of display

Page 29: Moeller GmbH GB Leistungsschalter Protective note to rule DIN ISO 16016 is to be considered The new line of circuit breaker IZM ILS-P / W. Wagner July.

Moeller GmbHGB Leistungsschalter

The new line of circuit breaker IZM

ILS

-P /

W. W

agne

r Ju

ly 2

003,

01

IZM

Bac

is D

evic

es, p

age

29P

rote

ctiv

e no

te to

rul

e D

IN IS

O 1

6016

is to

be

cons

ider

ed

Trip units: Digital overcurrent release with exclusiveexternal configuration XZMR

XZMR

Application: no access on site is allowed because

• high security is requested

• installation in public areas

No operating on site, no display available.

Parameterization only via parameter assignment module PG(E) or via PROFIBUS communication.

Ordering: Digital type with additional plus type +IZM-XZMR

! Always including COM-DP module and Breakter Status Sensor XBSS !

Page 30: Moeller GmbH GB Leistungsschalter Protective note to rule DIN ISO 16016 is to be considered The new line of circuit breaker IZM ILS-P / W. Wagner July.

Moeller GmbHGB Leistungsschalter

The new line of circuit breaker IZM

ILS

-P /

W. W

agne

r Ju

ly 2

003,

01

IZM

Bac

is D

evic

es, p

age

30P

rote

ctiv

e no

te to

rul

e D

IN IS

O 1

6016

is to

be

cons

ider

ed

Trip units: How to do the settings

1.

2.

3.

4.

4 protective ranges:

1. „L“ Overload protection

2. „S“ Short-time delay short-circuit prot.

3. „I“ Instantaneous short-circuit protection

4. „G“ Earth-fault protection

For each range all functions in one horizontal line:

• Current setting

• Graph with accentuated range

• LED for differentiated trip cause indication

• Delay time

Page 31: Moeller GmbH GB Leistungsschalter Protective note to rule DIN ISO 16016 is to be considered The new line of circuit breaker IZM ILS-P / W. Wagner July.

Moeller GmbHGB Leistungsschalter

The new line of circuit breaker IZM

ILS

-P /

W. W

agne

r Ju

ly 2

003,

01

IZM

Bac

is D

evic

es, p

age

31P

rote

ctiv

e no

te to

rul

e D

IN IS

O 1

6016

is to

be

cons

ider

ed

Trip units: Characteristics

Page 32: Moeller GmbH GB Leistungsschalter Protective note to rule DIN ISO 16016 is to be considered The new line of circuit breaker IZM ILS-P / W. Wagner July.

Moeller GmbHGB Leistungsschalter

The new line of circuit breaker IZM

ILS

-P /

W. W

agne

r Ju

ly 2

003,

01

IZM

Bac

is D

evic

es, p

age

32P

rote

ctiv

e no

te to

rul

e D

IN IS

O 1

6016

is to

be

cons

ider

ed

Trip units: Characteristics

Page 33: Moeller GmbH GB Leistungsschalter Protective note to rule DIN ISO 16016 is to be considered The new line of circuit breaker IZM ILS-P / W. Wagner July.

Moeller GmbHGB Leistungsschalter

The new line of circuit breaker IZM

ILS

-P /

W. W

agne

r Ju

ly 2

003,

01

IZM

Bac

is D

evic

es, p

age

33P

rote

ctiv

e no

te to

rul

e D

IN IS

O 1

6016

is to

be

cons

ider

ed

Trip units: Characteristics