Module 5: Wiring and Controls
TrueSTEAM™ Humidification Systems
![Page 2: Module 5: Wiring and Controls TrueSTEAM™ Humidification Systems.](https://reader033.fdocuments.us/reader033/viewer/2022061510/56649ecf5503460f94bdcdd5/html5/thumbnails/2.jpg)
Module 5: Wiring and Controlling TrueSTEAM
Key LearningKey Learning Which humidity controls to use and how to configure themWhich humidity controls to use and how to configure them
•What dips to set for different controls
• How to wire different controls
•When to choose one control over another
![Page 3: Module 5: Wiring and Controls TrueSTEAM™ Humidification Systems.](https://reader033.fdocuments.us/reader033/viewer/2022061510/56649ecf5503460f94bdcdd5/html5/thumbnails/3.jpg)
Getting Started
• Unplug TrueSTEAM and remove cover• Locate DIP Switches
DIP 1-2 = Flush timingsDIP 3 = RedLINK DIP 4 = Power monitoringDIP 5 = Air provingDIP 6 = not used
1 2 3 4 5 6
![Page 4: Module 5: Wiring and Controls TrueSTEAM™ Humidification Systems.](https://reader033.fdocuments.us/reader033/viewer/2022061510/56649ecf5503460f94bdcdd5/html5/thumbnails/4.jpg)
DIP 3 – RedLINK™ Wireless Technology
• DOWN: RedLINK disabled, use conventional terminals• UP: RedLINK enabled, use ABCD terminal
Prestige HD Thermostat
Conventional Terminals
Wireless Adapter
![Page 5: Module 5: Wiring and Controls TrueSTEAM™ Humidification Systems.](https://reader033.fdocuments.us/reader033/viewer/2022061510/56649ecf5503460f94bdcdd5/html5/thumbnails/5.jpg)
DIP 4 – Power Monitoring
• Down: TrueSTEAM looks for R and C input before allowing humidity - Use when humidity control is separate from system control
• UP: TrueSTEAM R and C input disabled - Use when humidity control is integrated with system control
![Page 6: Module 5: Wiring and Controls TrueSTEAM™ Humidification Systems.](https://reader033.fdocuments.us/reader033/viewer/2022061510/56649ecf5503460f94bdcdd5/html5/thumbnails/6.jpg)
System Fan Regulation
• Breaking G: Use when humidity control is separate from system fan control. - Fan delay advantage
• Not breaking G: Use when humidity control is integrated with system fan control.- Simple wiring advantage
![Page 7: Module 5: Wiring and Controls TrueSTEAM™ Humidification Systems.](https://reader033.fdocuments.us/reader033/viewer/2022061510/56649ecf5503460f94bdcdd5/html5/thumbnails/7.jpg)
DIP 5 – Air Proving
• DOWN: Air proving disabled.
• UP: Air proving enabled. - Added safeguard for air movement
![Page 8: Module 5: Wiring and Controls TrueSTEAM™ Humidification Systems.](https://reader033.fdocuments.us/reader033/viewer/2022061510/56649ecf5503460f94bdcdd5/html5/thumbnails/8.jpg)
Complete Diagrams For Provided Humidity Controls
![Page 9: Module 5: Wiring and Controls TrueSTEAM™ Humidification Systems.](https://reader033.fdocuments.us/reader033/viewer/2022061510/56649ecf5503460f94bdcdd5/html5/thumbnails/9.jpg)
Wiring a Manual Humidistat with Dry Contacts
![Page 10: Module 5: Wiring and Controls TrueSTEAM™ Humidification Systems.](https://reader033.fdocuments.us/reader033/viewer/2022061510/56649ecf5503460f94bdcdd5/html5/thumbnails/10.jpg)
Wiring TrueIAQ®
![Page 11: Module 5: Wiring and Controls TrueSTEAM™ Humidification Systems.](https://reader033.fdocuments.us/reader033/viewer/2022061510/56649ecf5503460f94bdcdd5/html5/thumbnails/11.jpg)
Wiring VisionPRO® IAQ
DIP 4
![Page 12: Module 5: Wiring and Controls TrueSTEAM™ Humidification Systems.](https://reader033.fdocuments.us/reader033/viewer/2022061510/56649ecf5503460f94bdcdd5/html5/thumbnails/12.jpg)
Wiring VisionPRO® IAQ With Fan Delay
DIP 4
![Page 13: Module 5: Wiring and Controls TrueSTEAM™ Humidification Systems.](https://reader033.fdocuments.us/reader033/viewer/2022061510/56649ecf5503460f94bdcdd5/html5/thumbnails/13.jpg)
Prestige™ RedLINK Connection
DIP 4
DIP 3
![Page 14: Module 5: Wiring and Controls TrueSTEAM™ Humidification Systems.](https://reader033.fdocuments.us/reader033/viewer/2022061510/56649ecf5503460f94bdcdd5/html5/thumbnails/14.jpg)
Wiring to TrueIAQ™ in a Zoned Application
![Page 15: Module 5: Wiring and Controls TrueSTEAM™ Humidification Systems.](https://reader033.fdocuments.us/reader033/viewer/2022061510/56649ecf5503460f94bdcdd5/html5/thumbnails/15.jpg)
Wiring to a VisionPRO® IAQ in a Zoned Application
![Page 16: Module 5: Wiring and Controls TrueSTEAM™ Humidification Systems.](https://reader033.fdocuments.us/reader033/viewer/2022061510/56649ecf5503460f94bdcdd5/html5/thumbnails/16.jpg)
RedLINK Connection in a Zoned Application
![Page 17: Module 5: Wiring and Controls TrueSTEAM™ Humidification Systems.](https://reader033.fdocuments.us/reader033/viewer/2022061510/56649ecf5503460f94bdcdd5/html5/thumbnails/17.jpg)
Wiring to a Dedicated Fan
![Page 18: Module 5: Wiring and Controls TrueSTEAM™ Humidification Systems.](https://reader033.fdocuments.us/reader033/viewer/2022061510/56649ecf5503460f94bdcdd5/html5/thumbnails/18.jpg)
Wet Switch Wiring in a Finished Space
![Page 19: Module 5: Wiring and Controls TrueSTEAM™ Humidification Systems.](https://reader033.fdocuments.us/reader033/viewer/2022061510/56649ecf5503460f94bdcdd5/html5/thumbnails/19.jpg)
Support Materials
• Detailed Training Materials on Installation Available!
Visit www.forwardthinking.honeywell.com
Enter literature form:
#69-2285: TrueSTEAM Installation Manual
![Page 20: Module 5: Wiring and Controls TrueSTEAM™ Humidification Systems.](https://reader033.fdocuments.us/reader033/viewer/2022061510/56649ecf5503460f94bdcdd5/html5/thumbnails/20.jpg)
Module 5: Wiring and Controlling TrueSTEAM
Key LearningKey Learning Which humidity controls to use and how to configure themWhich humidity controls to use and how to configure them
•What dips to set for different controls
• How to wire different controls
•When to choose one control over another