Module 3 DT-Drive Test Parameters
-
Upload
abdul-majeed-khan -
Category
Documents
-
view
29 -
download
0
description
Transcript of Module 3 DT-Drive Test Parameters
-
5/27/2018 Module 3 DT-Drive Test Parameters
1/10
Understanding Drive Data
EcNo, RSCP, UE Tx Power and RSSI
-
5/27/2018 Module 3 DT-Drive Test Parameters
2/10
Commercial in Confidence 2007-04-112
Introduction
The is presentation contains simplified guides for determining RF
failure reasons and air-interface quality from drive data. Intention of these guides is:
Assist in initiating pro-active optimization plans.
Determine if failure reason(s) is due to air-interface, sector, site,
transport or network issues?
General data preparation and visual analysis work flow is alsopresented.
It is recommended the Engineer understand UMTS call procedures,
network timers/thresholds and interface protocols to attain overall
network optimization skills.
-
5/27/2018 Module 3 DT-Drive Test Parameters
3/10
Commercial in Confidence 2007-04-113
Definitions3GPP TS 25.215
CPICH Ec/No:Received energy per chip divided by the power density in the band. The CPICH
Ec/No is identical to CPICH RSCP/UTRA Carrier RSSI. Measurement shall beperformed on the Primary CPICH.
UTRA CARRIER RSCP:Received Signal Code Power, the received power on one code measured on the
Primary CPICH.
Carrier RSSI:
Received Signal Strength Indicator. The received wide band power, includingthermal noise and noise generated in the receiver, within the bandwidth defined by
the receiver pulse shaping filter.
UeTxPwr:Total UE transmitted power on one carrier
Where: n = PSC
(mW)
)(mW
_
___/ RSSICarrier
RSCPCPICH
NoEc
n
n
(dB)(dBm)(dBm) ___ nn EcNoRSCPRSSICarrier
-
5/27/2018 Module 3 DT-Drive Test Parameters
4/10
Commercial in Confidence 2007-04-114
RSSI, RSCP and EcNo Relationship
0%
10%
20%
30%
40%
50%
60%
70%
80%
90%
100%
UARFCN
PercentageContribution
ToCarrierRSSI
Other & Noise
RSCP_psc8
RSCP_psc7
RSCP_psc6
RSCP_psc5
RSCP_psc4
RSCP_psc3
RSCP_psc2
RSCP_psc1
RSSI
RSCP
3.84Mhz
-
5/27/2018 Module 3 DT-Drive Test Parameters
5/10
Commercial in Confidence 2007-04-115
RSSI, RSCP and EcNo Relationship
mW dBm EcNo mW dBm
RSCP_psc1 5.01E-13 -93 -8.0 RSSI 3.16E-12 -85
RSCP_psc2 6.31E-14 -102 -17.0
RSCP_psc3 1.26E-13 -99 -14.0
RSCP_psc4 3.16E-13 -95 -10.0
RSCP_psc5 2.00E-13 -97 -12.0
RSCP_psc6 6.31E-14 -102 -17.0
RSCP_psc7 7.94E-14 -101 -16.0
RSCP_psc8 5.01E-14 -103 -18.0
Other & Noise 1.76E-12 -87.5 -2.5
mW dBm EcNo mW dBm
RSCP_psc1 3.98E-13 -94 -4.1 RSSI 1 .02E -12 -89. 9
RSCP_psc2
RSCP_psc3RSCP_psc4
RSCP_psc5
RSCP_psc6
RSCP_psc7
RSCP_psc8
Other & Noise 6.25E-13 -92.0 -2.1
0%
10%
20%
30%
40%
50%
60%
70%
80%
90%
100%
mW
PercentageContributionToCarrierRSSI
Other & Noise
RSCP_psc8
RSCP_psc7
RSCP_psc6
RSCP_psc5
RSCP_psc4
RSCP_psc3
RSCP_psc2
RSCP_psc1
0%
10%
20%
30%
40%
50%
60%
70%
80%
90%
100%
mW
PercentageCo
ntributionToCarrierRSSI
Other & Noise
RSCP_psc8
RSCP_psc7
RSCP_psc6
RSCP_psc5
RSCP_psc4
RSCP_psc3
RSCP_psc2
RSCP_psc1
-
5/27/2018 Module 3 DT-Drive Test Parameters
6/10
Commercial in Confidence 2007-04-116
Drive Data Preparation and Analysis
Following is a simple process:
Merge drive data files (as required)
Create plots of: Call events
Serving/best cell/PSC
EcNo/RSCP of serving/best PSC
RSSI plot
UeTx Power
Active set size, actual or simulated (optional) Number of PSCs within 5dB of serving/best PSC (optional)
Review call events Identify dropped calls, failed ASUs, etc
Areas with high number of ASUs
Identify areas with large number (>3) PSCs within 5dB
Use matrices in following slides to assist analysis
-
5/27/2018 Module 3 DT-Drive Test Parameters
7/10Commercial in Confidence 2007-04-117
Simplified RF Quality Matrix
EcNo, RSCP and RSSI
EcNo / RSCP
HIGH LOW
R
SSI
HIGH
LOW
Good Coverage
Good Quality
Low Pollution
Good Coverage
Poor Quality
Interference / Pollution
Poor Coverage
Good Quality
Low Pollution
Poor Coverage
Poor Quality
Possible Pollution
-
5/27/2018 Module 3 DT-Drive Test Parameters
8/10Commercial in Confidence 2007-04-118
Simplified RF Failure Symptom Matrix
EcNo, RSSI and UE TxPwr
EcNo
HIGH LOW
UE Tx Pwr
LOW HIGH LOW HIGH
RSSI
HIGH
LOW
No RF Issue.
Check Hardware,
Transport, Protocol,
Timer Expiration,
etc issues.
Limited UL.
Check UL Receive
Hardware Or UL
Interference.
DL Interference.
Check Missing
Neighbours Or
External
Interference.
UL/DL Interference.
Check Cell Overlap,
Serving Cell
Distance, Ant. Tilts
etc
DL Coverage. UL Coverage.
DL Coverage Hole.
Check Cell Overlap,
Serving Cell
Distance, Ant. Tilts
etc
Lack of Coverage
(DL & UL).
-
5/27/2018 Module 3 DT-Drive Test Parameters
9/10Commercial in Confidence 2007-04-119
0
-2
-4
-6
-8
-10
-12
-14
-16
-18
0
-2
-4
-6
-8
-10
-12
-14
-16
-18
0
-2
-4
-6
-8
-10
-12
-14
-16
-18
0
-2
-4
-6
-8
-10
-12
-14
-16-18
0
-2
-4
-6
-8
-10
-12
-14
-16
-18
0
-2
-4
-6
-8
-10
-12
-14
-16
-18
0
-2
-4
-6
-8
-10
-12
-14
-16
-18
0
-2
-4
-6
-8
-10
-12
-14
-16
-18
13:18:07
13:18:17
13:18:27
13:18:37
13:18:47
13:18:57
13:19:30
13:19:40
13:19:50
13:20:00
13:20:10
13:20:20
13:20:30
13:20:40
13:20:50
13:21:00
13:21:10
13:21:20
13:21:30
13:21:40
13:21:50
13:22:00
13:22:10
13:22:20
13:22:30
13:22:40
13:22:50
13:23:00
13:23:10
13:23:20
13:23:30
13:23:40
13:23:50
13:24:00
13:24:10
13:24:20
13:24:30
13:24:40
13:24:50
13:25:00
13:25:10
Time
EcNo(d
B)
-100.0
-90.0
-80.0
-70.0
-60.0
-50.0
-40.0
-30.0
-20.0
-10.0
0.0
10.0
20.0
13:18:07
13:18:18
13:18:29
13:18:40
13:18:51
13:19:25
13:19:36
13:19:47
13:19:58
13:20:09
13:20:20
13:20:31
13:20:42
13:20:53
13:21:04
13:21:15
13:21:26
13:21:37
13:21:48
13:21:59
13:22:10
13:22:21
13:22:32
13:22:43
13:22:54
13:23:05
13:23:16
13:23:27
13:23:38
13:23:49
13:24:00
13:24:11
13:24:22
13:24:33
13:24:44
13:24:55
13:25:06
13:25:17
Time
RSSI(dB)/UETxPwr(dBm)
0.0
1.0
2.0
3.0
4.0
ActiveSetSize
UeTxPwr RSSI ActiveSetSize
Example 1: Dedicated-modeDownlink
PSC_7
PSC_1
PSC_3
PSC_2
PSC_4
PSC_5
PSC_6
PSC_81
2
3
4
1
2 3
4
Dropped call
3
4
2
1
Serving Cell/PSC Plot
-
5/27/2018 Module 3 DT-Drive Test Parameters
10/10Commercial in Confidence 2007-04-1110
-20.0
-18.0
-16.0
-14.0
-12.0
-10.0
-8.0
-6.0
-4.0
-2.0
0.0
9:52:16
9:52:25
9:52:34
9:52:42
9:52:51
9:53:00
9:53:08
9:53:17
9:53:25
9:53:34
9:53:43
9:53:51
9:54:00
Ec
No(dB)
-95.0
-90.0
-85.0
-80.0
-75.0
-70.0
-65.0
-60.0
RSSI(dBm)
PSC1_EcNo PSC2_EcNo PSC3_EcNo PSC3_EcNo PSC4_EcNo RSSI
Example 2: Idle-mode
Impact of #servers and
individual contribution