Modern_Construction_Catalogs[1].2215649

51
Techniques Ahmad E. Mahmoud لمعاصر ا التشييدالوجات كتRev.: January 1 st , 2011

Transcript of Modern_Construction_Catalogs[1].2215649

Page 1: Modern_Construction_Catalogs[1].2215649

Techniques

Ahmad E. Mahmoud 

      

كتالوجات التشييد المعاصرRev.: January 1st , 2011 

Page 2: Modern_Construction_Catalogs[1].2215649

 

 

 

 

                           Published by: 

BuildingForma™ 410 Park Ave. 15th Floor, #8877 pmb Manha an, NY 10022 United States [email protected]  

 

  © 2010 BuildingForma™. All rights reserved.  The paper‐based edition of this document complies with the Permanent Paper Standard issued by the Na onal Informa on Standards Organiza on (Z39.48—1948). 

 

Page 3: Modern_Construction_Catalogs[1].2215649

المباني بالطوب والحجر - 04باب

Page 4: Modern_Construction_Catalogs[1].2215649

البناء بوحدات الطوب - 042000قسم

Page 5: Modern_Construction_Catalogs[1].2215649
Page 6: Modern_Construction_Catalogs[1].2215649

•• ••

••

••

••

.­~~ '0 ' ~;;~~

d .J .::.1 ;,..,1

1 .. d 9""is

• •

•• 6, • 1 d ~l.+JJ dJ

•• • J..

.;6­d...J ~-~uf-3 d~1

••d:a=a r .: d ~ Isl----..:I Ii.

..iJ .. 1u-d «i d.,,:a.. W_..~.....iiiiiiiI...

Page 7: Modern_Construction_Catalogs[1].2215649

--~

1 - ­ .. - . I

. ~: I -

Page 8: Modern_Construction_Catalogs[1].2215649

40

20

9.5 kg

NU40

20

D40

A40 D20

20

5 kg

C40 E40

20

8.5 kg

15

10

6.5 kg

Page 9: Modern_Construction_Catalogs[1].2215649

20

~.)W..>-='"i

ND30 D30

7.5 kg 20

SD40

20

RD40

11.2 kg 11.2 kg

20 ~~ 20 JJj.aA ~.)w ~i '-:-'~ 0-'~~l"Jjj..t...a ~~I~l:

LW20 B40 40

20 20

89.3 kg 5.8 kg

Page 10: Modern_Construction_Catalogs[1].2215649

TH20 SH20

13

9 kg

.--------::::­

20 11.3 kg

XH20 Y20

20

------­

12.8 kg

38 MLG20

20

9.5 kg 20

38 ML20

1S

F'O tl...i:iJL,. ,...44,.•:)U Lf~JJA -?Jw~i ",:-,y" ,

~\ w~\~ ~ Fl.' ji

.. ,~vi/BSr~", ~~~1 ~WI3wl..d...a\~ ~ ~.).J-*' '":-'~ ~1;;.i9

Page 11: Modern_Construction_Catalogs[1].2215649

P20

L20

G20 40

10

40

12 kg

40

14.7 kg

4..LaWI 01-,~ J..el.>. :-,W ~1 ,-:-,y,o

~~ I w l..:=SjiJ 13

ll.oWI0.J~ J..eb.l.#-,W ~i ,-:-,j-b

~~lw~.1":JI,

15

9 kg

4..LaWI ul-,~ J..>l.>. ~W ~I ,-:-,,,b

~~\ ul..:=S;:JIJ

20

20

20

LP20

L20

LG20

8.5 kg

14.3 kg

10.3 kg

~ J..e l.>. -,G-,W ~i ,-:-,,,b

40

15

20

20

20

Page 12: Modern_Construction_Catalogs[1].2215649

LS7 87 S 1

7 7

11

)Ij--'-")U( 'r ~ )J.....cl...> ~J~ ~i ",:-,j--b

,-:-,~IJ ~L.....1\ t=JL:;."" J ..::.,,~IJ wl...p'~\J

F9 40

GIOF

9

10

2.5 kg

'" ~01~~IJw~jlJjAL:...~JW~1",:""j-b

20 KD20S

40

GG20

20 20

20

5.5 kg 15 kg

Page 13: Modern_Construction_Catalogs[1].2215649

- -

- -

~ ~l '~L LwL ...L4J- - . ~ -. I· (" 'I ~~ ..L.J..L>J1 ..wLir.r-" . , f:l

·L ··'·lULLZ~J·' A·I\OU.~, ~r~.J

...lA.:t -,-:~I \ ; =?,,! j a ~ r..LA...j ~j ~j ~ ~~ ~':1 ..1l3 J..Ijb::JI

;;~I wi...L;l . a.!!jQ~"~\ a.......~1

~ ;;J~I dW..:..Ll1 d....jLai ~

~J~I ~")/I I..;-Jj-WI r~i

dJ~ ...lA.:tJ ;;y:.,~ cGlA~ ~J ~")/I

· {j")..L4.U j~1 I..;-J~\ [~l ~

w~lA..u1 w15y:., ~ 1.iJ1~?1~J

· ~ L w 15 . ~ II I.l.lJ.j C<..a l:9 u~ r~. or-'

a.......~1 LJ.e. ~ ~\ {j"L.\ J~

~clAl..GU..uGu~1~~~J

· 4)''>'j ~I~ t:!JWl lJA J.:..uJ1

~..r=Li.>JI ~tJ~~~

·a..afll

~\ h·J\\...u>~~>9

~~11..;-J#~ ~jlJ~\ .. ~ f:i:­~~I~J~\

;;~~ I..;-J#\ ~ ~1~1l,..La f:i: ­w~~...wl ~~ r~llJA d..J-J..rC

·,A_.II ;;~~~\A~l\~ - ­U..:t-:"""""" • .:r-'""' . f-':! ~ ,,~ ~..J ~~I ~~~I J~

fA t ~ d.5b ~ ~i ;;~lll

~-J I+i..a w~ ;;J...C ~ ~-J

. d.:~WI jy.bJ~ ~Ij->JI ulA~

~Jj ~ w~J ~~I "~3

L...,~I~Jj..Al.S ~JLaJ

;;~La u\ ~t ~L:o?1~ aiij4,,!~1

;;~ wl~J tJ~ a..aJLi.a 0~1

. - ~ d...Jk I-J.LIL -Lo::JI ~ _ .~. <3 •

.. l1i\ ~~~l5 ~I jSWI ~

· ~~I~ji La:\Ja.......~I..u.:J

Page 14: Modern_Construction_Catalogs[1].2215649

tYJI :::=::== ~~

~ -no. 0 '1"'\V""WI

0)~1 e"'AO::==:== "r~..l...Lo.l1

ty.Jl

I

Page 15: Modern_Construction_Catalogs[1].2215649

~ low, .!~ ~G-\ .!~ ~ ~1 ~tj triJ l

f""" r· x r~ ..,.,l.4.LI f""'" r·xr~ U'"WI

"~I ts".,.. .i' LJ.J.,JI

r,o Jo r ~ .lJ.o.lt r,o ?- JJ.o.lI

~r uJ

Page 16: Modern_Construction_Catalogs[1].2215649

,:;

~J~ ':14 ~~I ~ '-:! ';'O;J ~L.al ~3.;-W1 rJl..aJ c~LA ~~I

( ""

Saction shows the method of Roof tiles fixing

I

Page 17: Modern_Construction_Catalogs[1].2215649
Page 18: Modern_Construction_Catalogs[1].2215649

~t ,k

"j~i"

~~I-, li-J'-.~' Jj.s.U 4l~

'-$-J'~ I Jj.all

"'-' 0A ~-Jt,..~JI Jl4"u' 0A ~I j '"

_~~'~~0A-,i~I~-,

~..>---l'-' '=' " 'all ..9 ~ IJ _L!¥

~-JIJ >.ll AljL....c ~~L-4

U..9 ,aU Alj~ ~~l-4

J.=J >..U ~-,L4A ~~ l-4

~"J 1 'r -~.d_","""Q:z..l''\ ,,0

J.=J >.ll ~J-*3~ ~L.u ulj~~ ~ ;

~ ~.Jl' ~-'~, ~~U,

~L_1.tlJ " ,<'l.;J1 u's:.~1 ~ r ...1 .;..' '!I;

Page 19: Modern_Construction_Catalogs[1].2215649

•• - -----------

I

ILJlJI.PII Jjdll

Ll)~ a.:)~\ 4.ajl<J.\).Li.4 ~ ~4J.1 ~l.fJlr-J1 Jj..-J,l ~

~ ;.L.; .,)Ip 0-'" LJI.)~ 4.:Jlr-J1 c::..L..jl<J.\ Jj~1 I.:u, ~.J-'J

210 201

190

170

150

130 135

110

90

..-30

10

50

70

20

..>"'-"'"\ Y~...J\..l+

Red Brick Wall

20 10 15

Wall Thi kne

y..,b ....Jl~

~\

Concrete Brick Wall

10 20 20

..

5 5 10 ,5 i

25 J,j..<-< rJ~ j..o )I~

~ ~.JWI ~Iy<ll ,:?J....."JI Jj..-Lll":"'~.)-I ~i ~~ J~~

("-'-" , . ~L..... ':?J~ I ~')1 ,-:-,j------hll 0-" 0..l}-----4 .) I~ ~~

~~ c as~ J.;L.JI ,:?~1..39 ,...,110-" c:~ <L--.J3. 1..lj!

L...,L.t1J~(..:...ljl/..l"'{") ""., ~1~../~I<l.........:LAjl~~

~ ~I Wjl.ull ~ Jj...J ~.;I~I J~I ~'i ~~ 0i c..p..

.:-..Ij~~;"" bo.)..l e.r~ .,c 0"-LJI.J~ R~)..ro-J\ 4..AJWI ~J,;i=.;'1

ulj~ ~~ bo.)..l C'r~ ,VO 0"- ,...;,;;.....:)U R~).r-J! 4..AJW! ~J,;i=. 'lI

Page 20: Modern_Construction_Catalogs[1].2215649

JJ '3

-;t ·· ·

·tAr· \'\'\. 0j.a.l1 ·tA\r'I"'At·~YI..uI.·tAtA'\\Or \'j.>Jl.-tAHnV' d"j\.bL.., :~'

~C\: ~~ • t AnVVVV:....4:il...4. ,,..v ~. ~ - ;;J~I ~..J.I : ~.rII'pyl'

.~ ''1' vnvvvv ~1..hJ1 . , n , t"\ t"\ ~~I ·r ,orvvvv o~ ·r otrvvvv ~

-ooAAA·nr ~i . i t rAVVvv ill~ - t wovvvv .....9~1 -t r,\\vvvv ~

'O','r\O'1'o'\ ~I . o-vvllr\ 0 ~~I ·o-wnA'\V ~I) -0-'1"\'\'" w~~

.°.o,-n"0," rLA..u1 • 0 .,n·, rr .,>----t:-.JL ,00H·AAn ~, -0" \OAr'\t ~

+ '\V\ t r'I"''\''\' .: wI.;\..A~I-+'\'\OiAnWY: UJ~I - +'\Vt t '\Ar -Y'r : ~ .~.J-I.Wa11 ~.iJ11

www.maimni.com lal I@ 1m i i.co

I

Page 21: Modern_Construction_Catalogs[1].2215649

الكھربائية األعمال - 26 باب

Page 22: Modern_Construction_Catalogs[1].2215649

المتوسط الجھد وصل- فصل جھاز - 261300 قسم

Page 23: Modern_Construction_Catalogs[1].2215649

SIEMENS

Page 24: Modern_Construction_Catalogs[1].2215649

Air-insulated medium-voltage switchgear – cleverly switched, local added valuePeace of mind, saves lives, increases productivity, saves money

Answers for energy.

Page 25: Modern_Construction_Catalogs[1].2215649

Experience and quality for maximum system safety

The industrialized world of today is characterized by a rising energy demand and growing environmental consciousness con-currently with an increasing price pressure. At the same time, users are of course placing maximum demands regarding reli-ability, personal protection and productivity in connection with switchgear operation.

There is one thing you just have to rely on: smooth and safe operation of your system. Around the clock. Here, switchgear assemblies as points of intersection play a decisive role – and air-insulated switchgear concepts from our worldwide produc-tion locations offer the best solution with no doubt. As a pioneer for air-insulated switchgear we bring along 25 years of know-how in the development of switchgear and switching devices. Along with this, our manufacturing plants in all regions of the world ensure local added value and thus, permanent prox-imity to the customer, so that you can take full advantage of air- insulated technology: As insulating medium, air is available day and night, and withdrawable switchgear systems guarantee accessibility to all switchgear components at any time. With air-insulated switchgear from Siemens you are always on the safe side – our switchgear is type-tested for indoor installa-tion according to IEC 62271-200 or ANSI/IEEE C37.20.2. In this way you profit from our leading position as regards fulfillment of this new standard IEC 62271-200. Regardless of the fact that air-insulated switchgear from Siemens has always been a synonym for maximum personal and opera-tional safety as well as local added value.

Page 26: Modern_Construction_Catalogs[1].2215649

Keep everything going in your power supply system:

Air-insulated switchgear from Siemens – for sustainability, safety and efficiency

Increases productivityFunctions such as evidence of the making and breaking capac-ity for the built-in circuit-breakers and earthing switches – and even confinement of the arc to the respective compartment de-pending on the switchgear type – as well as designs equipped to meet maximum requirements with respect to the degree of protection provide uninterrupted operation and an appreciable increase of productivity.

Saves moneyThe compact design and the use of vacuum circuit-breakers pay off twice for the switchgear operator. On the one hand, build-ing costs can be reduced, and on the other hand, the mainte-nance-free design of the circuit-breakers enables continuous operation without expensive downtimes.

Peace of mindWith its sophisticated technology, a globally interconnected R&D network, a worldwide production and quality network and the fulfillment of all type and routine tests according to the re-quirements of the international standards without restrictions, air-insulated switchgear offers maximum peace of mind.

Saves livesAll air-insulated switchgear designs from Siemens are approved with internal arc classification IAC A FLR, loss of service continuity category LSC 2B, LSC 2A or LSC 1 depending on the switchgear type, as well as partition class PM. Thus they can be universally installed, fulfilling maximum requirements as regards personal protection.

Siemens – your partner on siteWe take care that you can “switch cleverly“. Combining innova-tion, experience and local added value. With comprehensive know-how, worldwide service – and profound understanding of your requirements in the most different regions due to local production capacity. Go and see for yourself!

Page 27: Modern_Construction_Catalogs[1].2215649

Local added value – systematically:

Worldwide production – complete processes – a quality standard

R&D headquarters in Germany concentrate international know-howAll global development activities are concentrated and controlled centrally: International development teams introduce the re-spective country-specific requirements in our R&D activities. A good basis for maximum development synergies, contributing to lean development cycles by means of optimal exchange of experience. High demands – in practical implementation:The �D-CAD procedureDuring the development and production phase, the utilization of 3D-CAD software ensures perfect quality and reliability. The in-dividual technical data of your switchgear is transferred directly from the purchase order to the production department via the design department. Using innovative technologies we can offer a maximum of quality and flexibility in production – with short delivery times.

Local added value – country-specific flexibilityHundreds of Siemens employees manufacture our air-insulated switchgear type series in different regions worldwide. In this way we do not only ensure the local know-how for the require-ments varying from country to country, but also integrate expe-rience from other locations. Production processes are docu-mented in a comprehensible way – to reach the quality level you, as our customer, can expect in a fast, safe and reproduc-ible way.

Strict eyes – to assure the qualityOur very modern, accredited testing laboratories ensure the high quality of our air-insulated switchgear. Besides type and routine tests for the individual switchgear type series, continu-ous process-accompanying quality assurance according to ISO 9001 and 14001 is performed. Being associated with PEHLA and DAR, our testing laboratories have the status of independent test institutes.

Page 28: Modern_Construction_Catalogs[1].2215649

Factory Corroios – Portugal

Products: • Air-insulated medium-voltage

switchgear (NXAIR, SIMOPRIME)

Switchgear Factory Frankfurt – Germany

R&D headquarters for air-insulated switchgear Products:

• SF6-insulated medium-voltage switchgear

Switchgear Factory Berlin – Germany

R&D headquarters for vacuum circuit-breakers Products:

• Vacuum circuit-breakers (3AH, SION)

• Vacuum contactors (3TL)

Factory Kyalami – Republic of South Africa

Products: • Air-insulated medium-voltage

switchgear (SIMOPRIME)

Factory Jundiai – Brazil

Products: • Air-insulated medium-voltage

switchgear (8BK, SIMOPRIME) • Assembly of vacuum circuit-

breakers

Factory Querétaro – Mexico

Products: • Air-insulated medium-voltage

switchgear (8BK, NXAIR, SIMOPRIME, 8BT2, GM)

• Vacuum circuit-breakers – indoor and outdoor installation

Factory Bogotá – Colombia

Products: • Air-insulated medium-voltage

switchgear (8BK, SIMOPRIME)

Page 29: Modern_Construction_Catalogs[1].2215649

� �

Factory Kartal – Turkey

Products: • Air-insulated medium-voltage

switchgear (8BK, 8BT, SIMOPRIME)

Interrupter Factory Berlin – Germany

R&D headquarters for vacuum interrupters Products:

• Vacuum interrupters for circuit-breakers and contactors

Factory Jakarta – Indonesia

Products: • Air-insulated medium-voltage

switchgear (8BK, SIMOPRIME)

Factory Shanghai – China

Products: • Air-insulated medium-voltage

switchgear (8BK, NXAIR S) • Vacuum circuit-breakers

Factory Kalwa – India

Products: • Air-insulated medium-voltage

switchgear (8BK80/88 PLUS) • Vacuum circuit-breakers –

indoor and outdoor installation

Factory Jeddah – Saudi Arabia

Products: • Air-insulated medium-voltage

switchgear (8BK)

Factory Karachi – Pakistan

Products: • Air-insulated medium-voltage

switchgear (8BK, SIMOPRIME)

Page 30: Modern_Construction_Catalogs[1].2215649

� �

Region Standard Loss of service continuity category, partition class

Internal arc classification

Busbar system

Switchgear type

UkV

Isc

kAIbusbar

AIfeeder

APage

Europe

Portugal IEC 62271-200 LSC 2B / PM IAC A FLR ISC, t Single /Double

NXAIR 12 31.5 2500 2500 8

NXAIR M 24 25 2500 2500 8

NXAIR P 15 50 4000 4000 8

SIMOPRIME 17.5 40 3600 3600 9

Turkey IEC 62271-200 LSC 2A / PM IAC A FLR ISC, t Single 8BT1 12 25 2000 2000 10

24 25 2000 2000

LSC 2B / PM 8BT2 36 31.5 2500 2500 10

LSC 1 8BT3 36 16 1250 1250 10

LSC 2B / PM SIMOPRIME 17.5 40 3600 3600 9

America

Mexico IEC 62271-200 LSC 2B / PM IAC A FLR ISC, t Single SIMOPRIME 17.5 40 3600 3600 9

8BT2 36 31.5 2500 2500 10

IEC 60298 Metal-clad IAC A FLR (IEC 60298)

Single 8BK20/8BK30

15 50 4000 4000

ANSI C37.20 Metal-clad acc. to standard Single GM SG 15 63 4000 4000 12

ANSI C37.20 Metal-clad acc. to standard Single GM 38 38 31.5 2500 2500 12

Brazil IEC 62271-200 LSC 2B / PM IAC A FLR ISC, t Single SIMOPRIME 17.5 40 3600 3600 9

IEC 60298 Metal-clad IAC A FLR (IEC 60298)

Single 8BK20/8BK30

15 50 4000 4000

Colombia IEC 62271-200 LSC 2B / PM IAC A FLR ISC, t Single SIMOPRIME 17.5 40 3600 3600 9

IEC 60298 Metal-clad IAC A FLR (IEC 60298)

Single 8BK20/8BK30

15 50 4000 4000

Asia

China IEC 62271-200, GB, DL

LSC 2B / PM IAC A FLR ISC, t Single NXAIR S 12 40 3150 3150 8

IEC 60298 Metal-clad IAC A FLR (IEC 60298)

Single 8BK20/8BK30

12 50 4000 4000

IEC 60298 Metal-clad – Single 8BK40 12 63 4500 4500

India IEC 62271-200 LSC 2B / PM IAC A FLR ISC, t Single 8BK80 12 44 3150 3150 11

36 31.5 3150 3150

8BK88 plus 12 25 1600 1600 11

Indonesia IEC 62271-200 LSC 2B / PM IAC A FLR ISC, t Single SIMOPRIME A4

24 25 2500 2500 9

IEC 60298 Metal-clad IAC A FLR (IEC 60298)

Single 8BK20/8BK30

12 50 4000 4000

Pakistan IEC 62271-200 LSC 2B / PM IAC A FLR ISC, t Single SIMOPRIME A4

24 25 2500 2500 9

IEC 60298 Metal-clad IAC A FLR (IEC 60298)

Single 8BK20/8BK30

12 50 4000 4000

Saudi Arabia IEC 60298 Metal-clad IAC A FLR (IEC 60298)

Single 8BK20/8BK30

15 50 4000 4000

Africa

South Africa IEC 62271-200 LSC 2B / PM IAC A FLR ISC, t Single SIMOPRIME 17.5 40 3600 3600 9

Your region, your requirements – and the suitable solution from Siemens. For every distribution level, every rating, every appli-cation and every switchgear type. To help you find information about the medium-voltage switchgear you need, we have listed our type series in the selection matrix given below in accor-dance with the most important criteria. For a fast overview, just leave this page unfolded.

The suitable switchgear – for every region and every requirement

Page 31: Modern_Construction_Catalogs[1].2215649

Type-tested, IEC 62271-200, metal-clad, loss of service continuity category: LSC 2B, partition class: PM Internal arc classification: IAC A FLR ≤ 50 kA 1sAs insulating medium, air is always available Evidence of the making and breaking capacity for the circuit-breakers and the make-proof earthing switches in the panel 42 kV, 1 min power-frequency withstand voltage for NXAIR and NXAIR S Single busbar, double busbar (back-to-back, face-to-face)Withdrawable vacuum circuit-breakerWithdrawable vacuum contactor Maximum availability due to modular design Selective shutdown by means of transformer principle and pressure-resistant partition Maximum security of operation by self-explaining operating logic Maintenance intervals > 10 years

NXAIR familyHigh-end technologyat its best

Switchgear type

Technical data

UkV

Isc

kAIbusbar

AIfeeder A

Widthmm

Heightmm

Depthmm

NXAIR ≤ 12 ≤ 31.5 ≤ 2500 ≤ 2500 400650800

2300 13501400

NXAIR M 24 ≤ 25 ≤ 2500 ≤ 2500 8001000

2550 1554

NXAIR P ≤ 15 4050

≤ 4000 ≤ 4000 4008001000

2550 16351650

NXAIR S ≤ 12 ≤ 40 ≤ 3150 ≤ 3150 800 2300 1350

NXAIR NXAIR M NXAIR P NXAIR S

Page 32: Modern_Construction_Catalogs[1].2215649

Type-tested, IEC 62271-200, metal-clad, loss of service continuity category: LSC 2B, partition class: PM Internal arc classification: IAC A FLR ≤ 40 kA 1sAs insulating medium, air is always available Evidence of the making and breaking capacity for the circuit-breakers and the make-proof earthing switches in the panelWithdrawable vacuum circuit-breakerWithdrawable vacuum contactorAll switching operations with door closed

SIMOPRIME familyThe first choicefor standard applications

Switchgear type

Technical data

UkV

Isc

kAIbusbar

AIfeeder A

Widthmm

Heightmm

Depthmm

SIMOPRIME ≤ 17.5 ≤ 40 ≤ 3600 ≤ 3600 400600800

2200 1860

SIMOPRIME A4

24 ≤ 25 ≤ 2500 ≤ 2500 800 1000

2250 1950

SIMOPRIME SIMOPRIME A4

Page 33: Modern_Construction_Catalogs[1].2215649

10

8BT1 8BT2 8BT3

Type-tested, IEC 62271-200, metal-clad, loss of service continuity category: LSC 2A for 8BT1, LSC 2B for 8BT2, LSC 1 for 8BT3, partition class: PM for 8BT1, 8BT2 Internal arc classification: IAC A FLR ≤ 31.5 kA 1sAs insulating medium, air is always available Evidence of the making and breaking capacity for the circuit-breakers and the make-proof earthing switches in the panelWithdrawable vacuum circuit-breakerAll switching operations with door closed

8BT familyCompact design andsimple construction

Switchgear type

Technical data

UkV

Isc

kAIbusbar

AIfeeder A

Widthmm

Heightmm

Depthmm

8BT1 ≤ 12 24

≤ 25 ≤ 25

≤ 2000 ≤ 2000

≤ 2000 ≤ 2000

600/800 800/1000

2050 2050

14101410

8BT2 36 ≤ 31.5 ≤ 2500 ≤ 2500 1550 2400 24502700

8BT3 ≤ 36 ≤ 16 ≤ 1250 ≤ 1250 1000 2400 1500

Page 34: Modern_Construction_Catalogs[1].2215649

11

8BK80 8BK88 PLUS

Switchgear type

Technical data

UkV

Isc

kAIbusbar

AIfeeder A

Widthmm

Heightmm

Depthmm

8BK80 ≤ 15 ≤ 44 ≤ 3150 ≤ 3150 600/800 2450 1750

8BK80 36 ≤ 31.5 ≤ 2000 ≤ 2000 1100 2250 2700

8BK88 PLUS ≤ 12 ≤ 25 ≤ 1600 ≤ 1600 600 2100 1350

8BK80 familyDesigned for local applications

Type-tested, IEC 62271-200, metal-clad, loss of service continuity category: LSC 2B, partition class: PM Internal arc classification: IAC A FLR ≤ 44 kA 1sAs insulating medium, air is always available Evidence of the making and breaking capacity for the circuit-breakers and the make-proof earthing switches in the panelWithdrawable vacuum circuit-breakerWithdrawable vacuum contactorAll switching operations with door closed

Page 35: Modern_Construction_Catalogs[1].2215649

1�

Type-tested, ANSI/IEEE C 37.20.2, metal-clad, tested for resistance to internal faultsAs insulating medium, air is always available Evidence of the making and breaking capacity for the circuit-breakers and the make-proof earthing switches in the panel Withdrawable vacuum circuit-breaker, also in “two-level design” All switching operations with door closed

Switchgear type

Technical data

UkV

Isc

kAIbusbar

AIfeeder A

Widthmm

Heightmm

Depthmm

GM SG ≤ 15 ≤ 63 ≤ 4000 ≤ 4000 914 (36‘‘)

2343 (92.25‘‘)

2502 (98.5‘‘)

GM 38 38 ≤ 31.5 ≤ 2500 ≤ 2500 1219 (48‘‘)

3302 (130‘‘)

3302 (130‘‘)

GM familyTheir strength is flexibility

GM SG GM 38

Page 36: Modern_Construction_Catalogs[1].2215649

1�

Circuit-breaker switchgear type NXAIR, NXAIR M, NXAIR P, up to �� kV, air-insulated HA 25.71.2007 German English

Circuit-breaker switchgear type NXAIR S, up to 1� kV, air-insulated English Chinese

Circuit-breaker switchgear type SIMOPRIME, up to 1�.� kV, air-insulated HA 26.11.2007 German English Spanish French

Circuit-breaker switchgear type SIMOPRIME A�, up to �� kV, air-insulated English

Circuit-breaker switchgear type �BT1, up to �� kV, air-insulated HA 26.31.2007 German English

Circuit-breaker switchgear type �BT�, up to �� kV, �1.� kA, air-insulated HA 26.41.2007 English Turkish

�BT�-SYSTEM, �� kV, 1� kA, air-insulated, truck-type switchgear English

�BK�0, metal-clad switchgear up to 1� kV English

�BK�� PLUS, compact metal-clad switchgear up to 1� kV English

Medium-voltage switchgear GM-SG, � kV – 1� kV English

OrderingFor further information about the switchgear, please refer to the following catalogs:

Please contact your local sales partner, who will send the selected information material to your address.

Company

Dept.

Name

Street

Postal code/city

Phone

Fax

Page 37: Modern_Construction_Catalogs[1].2215649

www.siemens.com/energy

Published by and Copyright © 2008Siemens AGEnergy SectorFreyeslebenstr. 191058 Erlangen, Germany

Siemens AGEnergy SectorPower Distribution DivisionMedium VoltageMozartstr. 31c91052 Erlangen, Germany

Please contact us at:Tel.: +49 180 / 524 70 00Fax: +49 180 / 524 24 71(Charges depending on provider)

E-Mail: [email protected] www.siemens.com/energy-support

Power Distribution DivisionOrder no. E50001-U229-A228-X-7600Printed in GermanyDispo 30400GB 080134 102449 WS 06085.0

Subject to change witout prior notice.The information in this document contains general descriptions of the technical options available, which may not apply in all cases. The requiredtechnical options should therefore be specified in the contract.

Page 38: Modern_Construction_Catalogs[1].2215649

Power Transmission and Distribution

Medium voltage – cleverly switched Gas-insulated switchgear: Compact, maintenance-free and climate-independent

Page 39: Modern_Construction_Catalogs[1].2215649

There is one thing you just have to rely on: Smooth and safe operation of your system. Around the clock. Here, switch-gear assemblies as points of intersection play a decisive role – and switchgear con-cepts from Siemens offer the best solu-tion with no doubt.

As a pioneer for gas-insulated switchgear we bring along �5 years of know-how, so that you can take full advantage of this technology – with a compact, main-tenance-free and climate-independent design. For lower ratings we also offer air-insulated switchgear type SIMOSEC with SF6 switch-disconnectors. The only decisive factor are your requirements.

With Siemens you are always on the safe side. Whether for secondary or for primary distribution switchgear – all our switchgear is already type-tested today for indoor installation according to IEC 6��71-�00 (in main aspects also according to ANSI C37.�0). In this way you profit from our leading position as regards fulfillment of this new standard. Regardless of the fact that Siemens switchgear has been a synonym for maxi-mum personal and operational safety.

We take care that you can “switch cleverly”. Combining innovation and experience. With comprehensive know-how, world-wide service – and profound understand-ing of your markets. Go and see for yourself!

For perfect operation of your system:

Page 40: Modern_Construction_Catalogs[1].2215649

High demands – in practical imple-mentation: The 3D CAD procedure

�D CAD design tools provide for the precise implementation of quality and reliability for our switchgear in develop-ment and production. The technical data of your switchgear is transferred directly from the purchase order to the produc-tion department via the design depart-ment with mathematical precision. Using innovative technologies we can offer a maximum of quality and flexibility in production – with short delivery times.

Everything tailor-made:The laser cutting system

The use of CNC-controlled laser cutting systems guarantees the manufacture of precise, exact parts with a surface free of scratches – at a high cutting speed. Maximum material utilization is ensured by the programs generated by the NC nesting processor.

For surge-proof operation:Cast-resin part manufacture

Insulating parts made of cast resin guarantee the dielectric strength of high-voltage phases to earth. The complete production process of such parts – which are essential for switch-gear – is integrated in our production. The quality of these components is 100% routine-tested by means of X-ray, tightness, high-voltage and partial discharge tests.

Systematic quality – by innovative procedures, technologies and production processes

With six product families for the primaryand secondary distribution level, theSwitchgear Factory Frankfurt/Main has a top position on the world market for gas-insulated switchgear.

The reason is a distinct understanding of quality, reaching far beyond the certifica-tion according to DIN EN ISO 9001 and 14001. Thousands of switchgear assem-blies running reliably all over the world are an impressive proof for this.

Decades of experience in development,manufacture, quality and environmental management as well as in service sup-port the leading position of the factory – as a worldwide center of competence and leading production for medium-volt-age switchgear from Siemens.

Page 41: Modern_Construction_Catalogs[1].2215649

� 4

Strict eyes: Type and routine tests as an integral part of quality assurance

Very modern testing laboratories ensurethe high quality of our products. Here, type and routine tests for the different switchgear types as well as continuous process-accompanying quality assurance according to ISO 9001 and 14001 are performed. Our accredited testing labo-ratories in Frankfurt/Main and Berlin are among the largest in the world.

Being associated with PEHLA, they have the status of independent test insti-tutes. Furthermore, our type tests are internationally accepted. For example, we take over the testing and certifica-tion of packaged substations from other manufacturers who do not have a test-ing laboratory of their own.

With standards to success:Assembly

Standards play an important part at the Switchgear Factory Frankfurt/Main. The sequence of a process is document-ed in a reproducible way – to guarantee that the quality level the customer ex-pects is reached in a fast, safe and re-producible way. For example, assembly: It is divided into clearly defined opera-tions and organized following the one-piece-flow principle.

Necessary tools are always ready to hand, parts and materials are supplied to the workplace – all this saves en-ergy, time and supports precision. Ac-cording to the push-pull principle, the subsequent process always controls the preceding process: For example, by the information that an operation has been completed or that material is required.

More precise, faster, tighter:The laser welding equipment

The application of laser welding tech-nology leads to maximum precision, fast throughput times and gas tight-ness. The electrical bushings of the stainless-steel vessels are welded in without seals – as well as the metal bellows for transmission of the operat-ing energies from outside the vessel to the switching devices located inside.

Everything tight, everything all right: Integral leakage detection system

“Sealed for life” is the target for each and every switchgear vessel. For this purpose, the vessel is evacuated to-gether with the test chamber and then filled separately with helium, which has a smaller molecular structure than SF6. If no escaping helium is detected, gas tightness is guaranteed for life. The helium gas is absorbed again, the switchgear vessel is refilled with SF6, and the filling socket is welded tight.

Page 42: Modern_Construction_Catalogs[1].2215649

5

Quality inmedium-voltage switchgearYour requirements – and the suitable so-lution from Siemens. For every distribu-tion level, every rating, every application and every switchgear type. According to the different criteria, you can easily find out on which page of this brochure the medium-voltage switchgear you need is described. Just leave this page unfolded.

Selection matrix

Secondarydistribution level

Gas insulation

Air insulation

Cubicle-type & metal-clad

Metal-clad

Metal- enclosed

Single

SIMOSEC

8DH10

8DJ

NXPLUS C

Primarydistribution level

Gas insulation

Air insulation

Cubicle-type & metal-clad

Metal-clad Single

SIMOSEC

8DH10

NXPLUS C

Single

NXPLUS

8DB10

NXPLUS C

NXPLUS

8DA10

Single

Double

Switchgear type

Busbar system

Enclosure/Partitions

InsulationDistributionlevel

Contents

17.5 �5 630 630 �4 �0 630 630

17.5 �5 1�50 630 �4 �0 1�50 630

15 31.5 �500 �500 �4 �5 �500 �000

17.5 �5 1�50 1�50 �4 �0 1�50 1�50

Page 6 – 7

Page 8

Page 9

Page 12

17.5 �5 1�50 630 �4 �0 1�50 630

15 31.5 �500 �500 �4 �5 �500 �000

17.5 �5 1�50 1�50 �4 �0 1�50 1�50

Page 8

Page 9

Page 12

36 31.5 �500 �500

40.5 40 4000 �500

�4 �5 �000 1�50

40.5 31.5 �500 �500

40.5 40 4000 �500 Page 10

Page 11

Page 9

Page 10

Page 11

Ibusbar

[A]

Ur

[kV]

IK

[kA]

Ifeeder

[A]

Electrical data (max.)

Generation leveland high-voltage system

Low voltage

Primary distribution level

Secondary distribution level

Page 43: Modern_Construction_Catalogs[1].2215649

6

8DJ10 switchgear for secondary distribution systems up to 24 kV

Ring-main feeder Transformer feeder

Scheme 10 Scheme 71 Scheme 6�

8DJ10 switchgear

Technical features Up to 17.5 kV, �5 kA, 1 s

Up to �4 kV, �0 kA, 3 s

Busbar up to 630 A

Feeders up to 630 A

Metal-enclosed

Gas-insulated

Block-type construction

Ring-main feeders, transformer feeders

Factory-assembled, type-testedswitchgear according to IEC 6��71-�00

Classification according to IEC 62271-200

Partition class PM

Loss of service continuity category

Switchgear with HV HRC fuses:

LSC �A

Accessibility to compartments

Busbar compartment: non-accessible

Switching-device compartment:

non-accessible

Cable compartment: interlock-controlled

Internal arcclassification (option)

Wall-standing arrangement:

IAC A FL �1 kA, 1 s

Dimensions

Switchgear height 1360 mm and 1650 mm

Switchgear depth 775 mm

Switchgear width 710 mm, 1060 mm, 1410 mm

Your advantages:Independent of environment and climateCompact Maintenance-free Safe for operatorsReliable and safe operationEcologicalCost-efficient

Product range

Page 44: Modern_Construction_Catalogs[1].2215649

7

8DJ20 switchgearfor secondary distribution systems up to 24 kV

Ring-main feeder Transformer feeder

Your advantages:Independent of environment and climateCompact Maintenance-freeSafe for operatorsReliable and safe operationEcologicalCost-efficient

Product range (in extracts)

Scheme 01 Scheme �1 Scheme 10 Scheme 71 Scheme 10 LST Scheme �1 LST

Ring-main feeder Circuit-breaker feeder

Switchgear with HV HRC fuses Switchgear with circuit-breaker feeder

8DJ20 switchgear

Technical features Up to 17.5 kV, �5 kA, 1 s

Up to �4 kV, �0 kA, 3 s

Busbar up to 630 A

Feeders up to 630 A

Metal-enclosed

Gas-insulated

Block-type construction

Ring-main feeders, transformer feeders,circuit-breaker feeders

Factory-assembled, type-testedswitchgear according to IEC 6��71-�00

Classification according to IEC 62271-200

Partition class PM

Loss of service continuity category

Switchgear without HV HRC fuses:

LSC �B

Switchgear with HV HRC fuses:

LSC �A

Accessibility to compartments

Busbar compartment: non-accessible

Switching-device compartment:

non-accessible

Low-voltage compartment:

tool-based

Cable compartment: interlock-controlled

Internal arc classification (option)

Wall-standing arrangement:

IAC A FL �1 kA, 1 s

Dimensions

Switchgear height 1�00 mm, 1400 mm or 1760 mm

Switchgear depth 775 mm

Switchgear width 510 mm, 710 mm, 1060 mm, 1410 mm, 1760 mm

Page 45: Modern_Construction_Catalogs[1].2215649

8

8DH10 switchgear for secondaryand primary distribution systems up to 24 kV

8DH10 switchgear

Technical features Up to 17.5 kV, �5 kA, 1 s

Up to �4 kV, �0 kA, 3 s

Busbar up to 1�50 A

Feeders up to 630 A

Metal-enclosed

Single busbar

Gas-insulated

Modular and extendable as individual panel or as panel block

Factory-assembled, type-testedswitchgear according to IEC 6��71-�00

Classification according to IEC 62271-200

Partition class PM

Loss of service continuity category

Panels without HV HRC fuses: LSC �B

Panels with HV HRC fuses: LSC �A

Accessibility to compartments

Busbar compartment: tool-based

Switching-device compartment:

non-accessible

Low-voltage compartment: tool-based

Cable compartment• with HV HRC fuses:• without HV HRC fuses:• panel type K:

interlock-controlledinterlock-controlledtool-based

Internal arcclassification (option)

Wall-standing arrangement: IAC A FL �1 kA, 1 s

Free-standing arrangement: IAC A FLR �1 kA, 1 s

Dimensions

Switchgear height 1400 mm, �000 mm with low-voltage compartment

Switchgear depth 775 mm

Panel widths 350 mm and 500 mm, metering panels 600 mm or 850 mm

Product range (in extracts)

Your advantages:Independent of environment and climateCompact Maintenance-freeSafe for operatorsReliable and safe operationEcologicalCost-efficient

Ring-main paneltype RK

Transformer paneltype TR

Circuit-breaker paneltype LS1

Bus sectionalizer type LT1

Circuit-breaker panel type LST1

Billing metering paneltype ME1

Page 46: Modern_Construction_Catalogs[1].2215649

9

NXPLUS C switchgear for secondaryand primary distribution systems up to 24 kV

NXPLUS C switchgear

Technical features Up to 15 kV, 31.5 kA, 3 s

Up to �4 kV, �5 kA, 3 s

Busbar up to �500 A

Feeders up to �500 A

Metal-enclosed

Single and double busbar

Gas-insulated

Hermetically sealed

Factory-assembled, type-testedswitchgear according to IEC 6��71-�00

Classification according to IEC 62271-200

Partition class PM

Loss of service continuity category

Panels without HV HRC fuses:

LSC �B

Panels with HV HRC fuses:

LSC �A

Accessibility to compartments

Busbar compartment: tool-based

Switching-device compartment:

non-accessible

Low-voltage compartment:

tool-based

Cable compartment• with HV HRC fuses:• without HV HRC fuses:

interlock-controlled tool-based

Internal arc classification

7.� kV up to 15 kV: IAC A FLR 31.5 kA, 1 s

17.5 kV up to �4 kV: IAC A FLR �5 kA, 1 s

Dimensions

Switchgear height ��50 mm

Switchgear depth 1�50 mm

Panel widths 600 mm, 1�00 mm at �000 A and �500 AProduct range (in extracts)

Circuit-breaker panel Disconnector panel Bus sectionalizer Switch-disconnector panel

Contactor panel Metering panel

Your advantages:Independent of environment and climateCompactMaintenance-freeSafe for operatorsReliable and safe operationEcologicalCost-efficient

Page 47: Modern_Construction_Catalogs[1].2215649

10

8DA/B10 switchgearfor primary distribution systems up to 40.5 kV

8DA/B10 switchgear

Technical features Up to 40.5 kV, 40 kA, 3 s

Busbar up to 4000 A

Feeders up to �500 A

Metal-enclosed

Single and double busbar

Gas-insulated

Sealed

Factory-assembled, type-testedswitchgear according to IEC 6��71-�00

Classification according to IEC 62271-200

Partition class PM

Loss of service continuity category LSC �B

Accessibility to compartments

Busbar compartment: tool-based

Switching-device compartment:

tool-based

Low-voltage compartment:

tool-based

Cable compartment: tool-based

Internal arc classification

IAC A FL 40 kA, 1 s

Dimensions

Switchgear height �350 mm (standard), �700 mm (option)

Switchgear depth SBB 3-pole: 1675 mm, SBB �-pole: 1�65 mm, SBB 1-pole: 915 mm DBB 3-pole: �710 mm

Panel width 600 mm

Product range (in extracts)

Circuit-breaker panel

SBB

8DA10 3-pole

Disconnector panel

SBB

8DA11 1-pole

Bus sectionalizer

SBB

Circuit-breaker panel

DBB

8DA12 2-pole

Bus coupler

DBB

Bus sectionalizer

DBB

8DB10 3-pole

Your advantages:Independent of environment and climateCompact Low-maintenanceSafe for operatorsReliable and safe operationEcologicalCost-efficient

Page 48: Modern_Construction_Catalogs[1].2215649

11

NXPLUS switchgearfor primary distribution systems up to 40.5 kV

NXPLUS switchgear

Technical features Up to 40.5 kV, 31.5 kA, 3 s

Busbar up to �500 A

Feeders up to �500 A

Metal-enclosed

Single and double busbar

Gas-insulated

Hermetically sealed

Factory-assembled, type-testedswitchgear according to IEC 6��71-�00

Classification according to IEC 62271-200

Partition class PM

Loss of service continuity category

LSC �B

Accessibility to compartments

Busbar compartment: tool-based

Switching-device compartment:

non-accessible

Low-voltage compartment:

tool-based

Cable compartment: tool-based

Internal arc classification

IAC A FLR 31.5 kA, 1 s

Dimensions

Switchgear height SBB �450 mm, DBB �600 mm

Switchgear depth SBB 1600 mm, DBB 1840 mm

Panel width 600 mm

Product range (in extracts)

Bus coupler

DBB

Bus sectionalizer

DBB

Circuit-breaker panel

IC DBB

Bus sectionalizer

SBB

Circuit-breaker panel

IC SBB

Circuit-breaker panel

OC SBB

Your advantages:Independent of environment and climateCompactMaintenance-freeSafe for operatorsReliable and safe operationEcologicalCost-efficient

Page 49: Modern_Construction_Catalogs[1].2215649

1�

SIMOSEC switchgear

Technical features Up to 17.5 kV, �5 kA, 1 s

Up to �4 kV, �0 kA, 3 s

Busbar and feeders up to 1�50 A

Metal-enclosed

Single busbar

Air-insulated

Hermetically sealed switchgear vessel

Factory-assembled, type-tested switchgear according to IEC 6��71-�00

Classification according to IEC 62271-200

Partition class PM

Loss of service continuity category

Panels without HV HRC fuses, as well as panel types without removable circuit-breaker type 3AH6: LSC �B

Panels with HV HRC fuses, as well as panel types with 3AH6: LSC �A

Accessibility to compartments

Busbar compartment: tool-based

Switching-device compartment:

non-accessible

Switching-device compartment with 3AH6:

accessible, interlock-controlled

Low-voltage compartment: tool-based

Cable compartment• without HV HRC fuses:• with HV HRC fuses:

tool-basedinterlock-controlled,tool-based

Internal arc classification (option)

Wall-standing arrangement: IAC A FL �0 kA, 1 s

Free-standing arrangement: IAC A FLR �0 kA, 1 s

Dimensions

Switchgear height 1750 mm (standard), �100 mm (option)

Switchgear depth 1�30 mm

Panel widths 375 mm, 500 mm, 750 mm

Ring-main panel RK

Metering panel ME1

Circuit-breaker panel LS1 with 3AH5

Transformer panelTR

Circuit-breaker panel LS11 with 3AH6

Your advantages:CompactSafe for operatorsReliable and safe operationEcologicalCost-efficient

This switchgear is also available as SIMOSEC ANSI, and it is type-tested and UL-listed according to the standard ANSI/IEEE C37.

Product range (in extracts)

SIMOSEC switchgear for secondaryand primary distribution systems up to 24 kV

Page 50: Modern_Construction_Catalogs[1].2215649

13

25 years of gas-insulated medium- voltage switchgear from Siemens

In 198� Siemens introduced a world nov-elty to the market: The first gas-insulated switchgear for medium voltage. Right from the beginning, this innovation has written a success story.

For us, this is a commitment for con- tinuous development: As a leader in technology we have been permanently redefining performance and economic efficiency for a quarter century – a process you, as the customer, benefit from. Even tomorrow and the day after tomorrow.

Innovationby tradition

Milestones from a quarter century 1977Siemens brings the first vacuum circuit-breaker to market, setting new standards regarding the reachable number of op-erating cycles, necessary maintenance, small dimensions, reliability and environ-mental independence.

1982The first gas-insulated switchgear for the primary distribution level is available with the type designation 8DA10 and 8DB10. And for the secondary distribution level, Siemens offers the type 8DJ10 as the first hermetically welded, maintenance-free gas-insulated switchgear worldwide. This is the first switchgear that is extremely compact and climate-independent.

1985With 7SA50�, Siemens was the first worldwide provider to introduce a micro-processor-based multifunction protection relay to the market, thus initiating the age of numerical protection and control systems.

1993As the first switchgear of its kind, 8DH10 switchgear for the secondary distribution level combines hermetically welded tech-nology and maintenance-free design with simple extensibility. In the same year, the first maintenance-free, hermetically welded switchgear appears on the prima-ry distribution level: NXPLUS C. Gas work for installation and extension is therefore a thing of the past.

2000Siemens offers sealed systems for the complete medium-voltage range – up to 40.5 kV, 40 kA, 4500 A.

2006Every gas-insulated switchgear from Siemens complies with the new switch-gear standards IEC 6��71-100 and -�00.

First gas-insulated switchgear forsecondary distribution levels8DJ10 – Stadtwerke Lambrecht (Pfalz) GmbH, Germany

First gas-insulated switchgear forprimary distribution levels8DA10 – BELG (today, E.ON Bayern AG),Station Kulmbach Mitte, Germany

Page 51: Modern_Construction_Catalogs[1].2215649

14

Subject to change without prior noticeOrder no. E50001-U��9-A310-X-7600Printed in GermanyDispo 30403GB 0700�1 10��81 WS 0�076.

The information in this document contains general descriptions of the technical features, which may not always be available.An obligation to provide the respective performance feature shall exist only if expressly agreed in the terms of contract.

Siemens AGPower Transmission and DistributionMedium Voltage DivisionMozartstr. 31 c9105� ErlangenGermany

www.siemens.com/energy

For questions on power transmission anddistribution, please contact our CustomerSupport Center, �4 hours a day.

Tel.: +49 180 / 5�4 70 00Fax: +49 180 / 5�4 �4 71(Subject to charge: e.g. 1� ct/min)

E-mail: [email protected]/energy-support