MODEL STUDY OF SPILLWAY ENID DAM, YOCONA RIVER … · The model study of the spillway for Enid Dam,...
Transcript of MODEL STUDY OF SPILLWAY ENID DAM, YOCONA RIVER … · The model study of the spillway for Enid Dam,...
![Page 1: MODEL STUDY OF SPILLWAY ENID DAM, YOCONA RIVER … · The model study of the spillway for Enid Dam, proposed for con struction on the Yocona River in Mississippi, was concerned with](https://reader034.fdocuments.us/reader034/viewer/2022042209/5eac857b9c764034935bb6cc/html5/thumbnails/1.jpg)
MRC-WES-ISQ-FEB 47
WAR DEPARTMENT
CORPS OF ENGINEERS
MISSISSIPPI RIVER COMMISSION
MODEL STUDY OF SPILLWAY
ENID DAM, YOCONA RIVER
MISSISSIPPI
WAR DEPARTMENT tf'IIIOI ... llltlf 0P IIIINIEIIS
.J.IBMR!
TECHNICAL MEMORANDUM NO. 2-223
WATERWAYS EXPERIMENT STATION
VICKSBURG, MISSISSIPPI
MARCH 1947
![Page 2: MODEL STUDY OF SPILLWAY ENID DAM, YOCONA RIVER … · The model study of the spillway for Enid Dam, proposed for con struction on the Yocona River in Mississippi, was concerned with](https://reader034.fdocuments.us/reader034/viewer/2022042209/5eac857b9c764034935bb6cc/html5/thumbnails/2.jpg)
Report Documentation Page Form ApprovedOMB No. 0704-0188
Public reporting burden for the collection of information is estimated to average 1 hour per response, including the time for reviewing instructions, searching existing data sources, gathering andmaintaining the data needed, and completing and reviewing the collection of information Send comments regarding this burden estimate or any other aspect of this collection of information,including suggestions for reducing this burden, to Washington Headquarters Services, Directorate for Information Operations and Reports, 1215 Jefferson Davis Highway, Suite 1204, ArlingtonVA 22202-4302 Respondents should be aware that notwithstanding any other provision of law, no person shall be subject to a penalty for failing to comply with a collection of information if itdoes not display a currently valid OMB control number
1. REPORT DATE MAR 1947 2. REPORT TYPE
3. DATES COVERED 00-00-1947 to 00-00-1947
4. TITLE AND SUBTITLE Model Study of Spillway Enid Dam, Yocona River Mississippi
5a. CONTRACT NUMBER
5b. GRANT NUMBER
5c. PROGRAM ELEMENT NUMBER
6. AUTHOR(S) 5d. PROJECT NUMBER
5e. TASK NUMBER
5f. WORK UNIT NUMBER
7. PERFORMING ORGANIZATION NAME(S) AND ADDRESS(ES) U.S. Army Corps of Engineers,Waterway Experiment Station,3903 HallsFerry Road,Vicksburg,MS,39180
8. PERFORMING ORGANIZATIONREPORT NUMBER
9. SPONSORING/MONITORING AGENCY NAME(S) AND ADDRESS(ES) 10. SPONSOR/MONITOR’S ACRONYM(S)
11. SPONSOR/MONITOR’S REPORT NUMBER(S)
12. DISTRIBUTION/AVAILABILITY STATEMENT Approved for public release; distribution unlimited
13. SUPPLEMENTARY NOTES
14. ABSTRACT
15. SUBJECT TERMS
16. SECURITY CLASSIFICATION OF: 17. LIMITATION OF ABSTRACT Same as
Report (SAR)
18. NUMBEROF PAGES
111
19a. NAME OFRESPONSIBLE PERSON
a REPORT unclassified
b ABSTRACT unclassified
c THIS PAGE unclassified
Standard Form 298 (Rev. 8-98) Prescribed by ANSI Std Z39-18
![Page 3: MODEL STUDY OF SPILLWAY ENID DAM, YOCONA RIVER … · The model study of the spillway for Enid Dam, proposed for con struction on the Yocona River in Mississippi, was concerned with](https://reader034.fdocuments.us/reader034/viewer/2022042209/5eac857b9c764034935bb6cc/html5/thumbnails/3.jpg)
. --
(
SPILLWAY---ENID DAM
ORIGINAL DESIGN
)
'
' I .· r ,-. \
• J
' 1
'· . ,, .. }' '' I .... 1&! • \\\. )~, • . . .
![Page 4: MODEL STUDY OF SPILLWAY ENID DAM, YOCONA RIVER … · The model study of the spillway for Enid Dam, proposed for con struction on the Yocona River in Mississippi, was concerned with](https://reader034.fdocuments.us/reader034/viewer/2022042209/5eac857b9c764034935bb6cc/html5/thumbnails/4.jpg)
CONTENTS
SYNOPSIS
PART I: INTRODUCTION .
PART II: THE PROTOTYPE .
Design Features of Enid Dam Project . Purpose of the Model Study . . . . .
PART III: THE JVIODEL
Design Considerations Interpretation of JVIodel Results Description of the Model JVIethod of Operation . .
PAR'I' IV: NARRATIVE OF TESTS
Tests of Approach Channel . Tests of Spillway v\Jeir Tests of Conduits ......... . Tests of Stilling Basin . Summary of Stilling-Basin Test Results
PART V: SU~WffiRY OF TEST RESULTS • • • • • • • ' ' ' • • <; • • • •
TABLES l-2
PLATES l-45
3
4
4 6
8
8 9 9
11
13
13 17 21 21 53
56
i
![Page 5: MODEL STUDY OF SPILLWAY ENID DAM, YOCONA RIVER … · The model study of the spillway for Enid Dam, proposed for con struction on the Yocona River in Mississippi, was concerned with](https://reader034.fdocuments.us/reader034/viewer/2022042209/5eac857b9c764034935bb6cc/html5/thumbnails/5.jpg)
MODEL STUDY OF THE SPILLWAY
FOR
ENID DAM, YOCONA RIVER, MISSISSIPPI
SYNOPSIS
The model study of the spillway for Enid Dam, proposed for con
struction on the Yocona River in Mississippi, was concerned with
hydraulic performance of the spillway, particularly as affected by the
use of sloping sidewalls for the spillway chute and stilling basin.
This study was of an unusual nature in that it was concerned chiefly
with hydraulic-jump action within a stilling basin of trapezoidal cross
section, a subject on which very little information is available. It
was determined from the model study that certain alterations of the
original spillway design were necessary to improve hydraulic performance.
In the original design, the projection formed just below the
spillway crest by intersection of the side walls of the chute and the
approach channel caused standing waves on the chute. Alleviation of
this condition was accomplished by extending the chute walls farther
upstream to intersect the approach channel walls either at, or upstream
from, the spillway crest.
The performance of the stilling basin as originally designed was
found to be unsatisfactory, and 36 alternate designs were investigated.
It was demonstrated that satisfactory stilling action could be obtained
in a trapezoidal stilling basin (with sloping side walls) by either of
two methods: (a) arching the floor of the spillway chute, or (b)
![Page 6: MODEL STUDY OF SPILLWAY ENID DAM, YOCONA RIVER … · The model study of the spillway for Enid Dam, proposed for con struction on the Yocona River in Mississippi, was concerned with](https://reader034.fdocuments.us/reader034/viewer/2022042209/5eac857b9c764034935bb6cc/html5/thumbnails/6.jpg)
2
constructing large deflector blocks on the chute near its junction with
the basin. (In either of these cases, an end sill and two rows of
baffle piers were required.) This fact notwithstanding, the model tests
clearly indicated the superiority of the standard rectangular stilling
basin (vertical side walls) for providing good flow conditions in the
basin proper. Furthermore, velocities over the riprapped side slopes of
the exit channel were lower with the rectangular basin than with the
trapezoidal basin. It was also demonstrated by the model tests that
sloping or vertical side walls for the spillway chute would operate with
equal efficiency, :c·rovided that proper transitions were effected between
the walls of the chute and the stilling basin.
Although the model study indicated the superiority of a rectangu
lar section for the stilling basin, consideration should be given to the
practicability of using a trapezoidal basin in cases where this design
is clearly indicated by considerations of economy of construction or
availability of materials,
![Page 7: MODEL STUDY OF SPILLWAY ENID DAM, YOCONA RIVER … · The model study of the spillway for Enid Dam, proposed for con struction on the Yocona River in Mississippi, was concerned with](https://reader034.fdocuments.us/reader034/viewer/2022042209/5eac857b9c764034935bb6cc/html5/thumbnails/7.jpg)
PART I: INTRODUCTION
1. A hydraulic model atudy of the spillway for Enid Dam was
recommended by the President, ~lississippi River Commission, in a letter
dated 6 February 1943 to the Chief of Engineers, U. S. Army. Authority
for the study was granted by the Chief of Engineers in letter of 9
February 1943 to the President, Mississippi River Commission. The model
study was conducted by the U. S. Waterways Experiment station during the
period February to December 1943.
2. The original design of the proposed Enid Dam spillway was
furnished the Experiment Station by the Office of the President,
J!Iississippi River Commission. The model testing program included
various features of design and design modifications originating in the
Office, Chief of Engineers; the Office of the President, Mississippi
River Commission; the Harza Engineering Company (which prepared the
original design under contract); and the Experiment Station. Close
liaison was maintained between the Experiment Station and the Office of
the President, Vnssissippi River Commission, throughout the course of
the model study through consultations with Messrs. George B. Davis and
James E. Sanders, Engineers, of the latter office. Progress reports
were submitted periodically by the Experiment Station, and test results
were forwarded in preliminary reports as data became available.
3. The model study was conducted in the Hydraulics Division
under the sup~rvision of Mr. Frederick R. Brown, Engineer, Chief of the
Structures Branch. ~rr. Brown was assisted by Mr. William B. Tanner,
Engineer, and by Mr. Edwin S. Melsheimer, Engineering Aide.
3
![Page 8: MODEL STUDY OF SPILLWAY ENID DAM, YOCONA RIVER … · The model study of the spillway for Enid Dam, proposed for con struction on the Yocona River in Mississippi, was concerned with](https://reader034.fdocuments.us/reader034/viewer/2022042209/5eac857b9c764034935bb6cc/html5/thumbnails/8.jpg)
4
PART II : THE PROTOTYPE-i~
D~sign Features of Enid Dam Project
4. Enid Dam is proposed for construction on the Yocona River, at
a location approximately 3 miles north of Enid, Mississippi. Figure l
i~ a vicinity map of the area. The dam will provide flood protection
for the delta reaches of the Yazoo River basin above the head of the
Mississippi River backwater.
The proposed structure will
consist of an earth-fill em-
bankment containing approxi-
mately 6,260,000 cu yd of
material. The main section
of the dam will be about
8,400 ft long, and will have
an average height above the
valley floor of 78 ft and a
maximum height above the bed
of the river of 99 ft. The
reservoir at spillway-crest
elevation will have an area
of 28,000 acres, a storage
capacity of 660,000 acre-ft,
S S E E
rfj JACKSON
NOTE: SHADED AREAS DENOTE RESERVOIRS FORMED
BY PROPOSED OR EXISTING STRUCTURES.
ENID DAM YOCONA RIVER, MISSISSIPPI
LOCATION MAP
10 o 10 20 3<:1 40 $0WILES
Figure l
-i~ Information on the prototype was obtained from the 11 Analysis of Design, Enid Reservoir, Yocona River, Mississippi. 11
![Page 9: MODEL STUDY OF SPILLWAY ENID DAM, YOCONA RIVER … · The model study of the spillway for Enid Dam, proposed for con struction on the Yocona River in Mississippi, was concerned with](https://reader034.fdocuments.us/reader034/viewer/2022042209/5eac857b9c764034935bb6cc/html5/thumbnails/9.jpg)
and will extend up the Yocona River valley approximately 20 miles. At
conservation or permanent pool elevation of 230~~, th@ reservoir will
have an area of 6,100 acres and a storage capacity of 57,600 acre-ft.
5. Reference is made to figure 2 and plate l showing details of
the spillway and stilling basin as originally designed. It was proposed
that this structure, with a 237-ft clear crest width at elevation 268,
be located in the north abutment ridge to provide passage for extraordi-
nary floods from a full reservoir. The proposed structure includes a
flared approach channel, a low round-crested weir, a l-on-3 sloped
trapezoidal-shaped chute, a trapezoidal-shaped stilling basin, a short
outlet channel with derrick-stone and riprap pavement, and an unlined
earth pilot channel. The structure is designed to discharge 49,700 cfs
with the pool at elevation 284.
6. The following data apply to structural and hydraulic features
of the spillway and stilling basin as originally designed:
Structural
Height of spillway weir 10 ft
Elevation of crest . . • 268
Width of spillway crest 237 ft
Width of chute . . 200 ft
Slope of chute l on 3
Length of stilling basin 360 ft
Width of stilling basin 200 ft
Elev. of stilling basin 190
Hydraulic
Design discharge • • 49,700 cfs
Design head on crest 16 ft
Design headwater elevation . . . . 284
Minimum tailwater elevation for design discharge .
Maximum tailwater elevation for design discharge
220.4
243.6
~~ All elevations are in feet above mean sea level.
5
![Page 10: MODEL STUDY OF SPILLWAY ENID DAM, YOCONA RIVER … · The model study of the spillway for Enid Dam, proposed for con struction on the Yocona River in Mississippi, was concerned with](https://reader034.fdocuments.us/reader034/viewer/2022042209/5eac857b9c764034935bb6cc/html5/thumbnails/10.jpg)
6
7. The outlet structures as originally designed are shown by
figure 2. They were designed to serve the dual purpose of controlling
outflow during the flood season, and of emptying the flood-control pool
prior to the beginning of the next normal flood season. The type of
outlet selected for this purpose was a double, modified, inverted, egg
shaped conduit controlled by a two-gate intake. The inverts of the
gates were at elevation 215 and the gate passages were raised at the
entrance to form a weir at elevation 227.5. Although this type outlet.
was utilized in the model study of Enid Dam, later plans indicated that
for structural reasons the prototype will probably be constructed with
separate outlet structures.
Purpose of the Model Study
8. The general purpose of the model study was to investigate the
hydraulic performance of the spillway and appurtenant structures as
originally designed, with a view toward developing such design modifica
tions as might be necessary to assure the desired capacity and hydraulic
safety of the structures. The model study was particularly concerned
with the unusual problem of obtaining hydraulic-jump action in a still
ing basin of trapezoidal cross section, as contemplated in the original
design. The use of sloping side walls for the chute and stilling basin
had been planned as a war-time measure to minimize the amount of steel
required for construction.
![Page 11: MODEL STUDY OF SPILLWAY ENID DAM, YOCONA RIVER … · The model study of the spillway for Enid Dam, proposed for con struction on the Yocona River in Mississippi, was concerned with](https://reader034.fdocuments.us/reader034/viewer/2022042209/5eac857b9c764034935bb6cc/html5/thumbnails/11.jpg)
7
Ups tream View
Downs tream View
Figure 2. l - to- 30- scale comprehensi ve model of the original design
![Page 12: MODEL STUDY OF SPILLWAY ENID DAM, YOCONA RIVER … · The model study of the spillway for Enid Dam, proposed for con struction on the Yocona River in Mississippi, was concerned with](https://reader034.fdocuments.us/reader034/viewer/2022042209/5eac857b9c764034935bb6cc/html5/thumbnails/12.jpg)
8
PART III: THE MODEL
Design Considerations
9. Application of the laws of similitude to small-scale models of
hydraulic structures has been fully discussed in previous technical
memoranda of the Experiment Station. lVJo st important, however, to the
design and operation of the Enid spillway model was the consideration
that in overfall structures such as this, fluid motion is predominantly
affected by the force of gravity; thus, hydraulic quantities vary between
model and prototype systems according to the Froudian relationship.
10. In meeting the requirements for complete dynamic similarity
between model and prototype systems, the model representation of proto
type surfaces must be smoother as the scale ratio decreases. For the
scale ratio of 1 to 30 adopted for the Enid model, the roughness scale
should. be 1 to 1.762. Assuming the roughness of the prototype to be
about 0.013, the model roughness should be about 0.0074. In construction
of the Enid model, care was taken to make all spillway surfaces as smooth
as possible, and a value of about 0.0085 is believed to have been
attained. The difference between this value and the theoretically
correct value of 0.0074 has been found to be insignificant in the per
formance of the stilling basin. In the calibration of the spillway,
however, the variation in roughness might Lave resulted in a slight
reduction of model spillway efficiency.
11. Relationships for the transference of model data to prototype
equivalents, or vice versa, ~re expressed by the following tabulation,
'~rhere the subscript r represents the model-to-prototype ratio:
![Page 13: MODEL STUDY OF SPILLWAY ENID DAM, YOCONA RIVER … · The model study of the spillway for Enid Dam, proposed for con struction on the Yocona River in Mississippi, was concerned with](https://reader034.fdocuments.us/reader034/viewer/2022042209/5eac857b9c764034935bb6cc/html5/thumbnails/13.jpg)
9
Dimension Relationship ---------Length Lr l/30
Area Ar Lr 2 l/900 .
Time Tr = L~l/2 L
1/5.477
Velocity vr L l/2 r l/5.477
Discharge Qr L 5/2 r l/4929
Interpretation of Model Results
12. Because of the nature of the quantities involved, certain of
the model data may be accepted quantitatively, while other data are
reliable only in a qualitative sense. Measurements in the model of dis-
charges, water-surface elevations, velocities, and pressures (all posi-
tive and negative pressures corresponding to pressures above the cavita-
tion range in the prototype) can be transferred quantitatively from
model to prototype by means of the above scale relationships. Evidences
of scour, ·however, are to be considered as only qualitatively reliable,
since it has not yet been proven possible to simulate quantitatively in
a model the resistance to erosion of a prototype bed material.
Description of the Model
13. The model of Enid Dam spillway was built to the linear-scale
ratio of l to 30. There were reproduced in the model 420 ft of the
approach channel, the spillway crest and chute, the stilling basin, the
outlet structures, and about 300 ft of the exit channel. The dimensions
of model structures were in accordance with prototype plans and
![Page 14: MODEL STUDY OF SPILLWAY ENID DAM, YOCONA RIVER … · The model study of the spillway for Enid Dam, proposed for con struction on the Yocona River in Mississippi, was concerned with](https://reader034.fdocuments.us/reader034/viewer/2022042209/5eac857b9c764034935bb6cc/html5/thumbnails/14.jpg)
10
specifications furnished by the Harza Engineering Company and the Office
of the President, ~ussissippi River Commission.
14. That portion of the model representing the approach channel,
the spillway, and overbank areas was molded in cement mortar to sheet
metal templets. The portion of the model representing the exit channel
was molded in sand; for velocity tests this sand bed was rendered immov
able by application of a thin coating of cement mortar. The intake
structure, stilling basin, end sill, and baffle piers were modeled of
wood ~nd treated with waterproofing material to prevent expansion. The
outlet conduits were shaped in sheet metal. Care was exercised to
properly shape all surfaces and to make them as smooth as possible.
15. Water used for operation of the model was supplied by centrif
ugal and axial-flow pun1ps connected in such manner as to permit flexibil
ity of pump operation. The water was pumped from a large sump and
measured by means of two venturi tubes. The flow from the supply lines
spilled into a headbay where it was stilled by baffles prior to its en
trance into the model. After passing through the model, the water flowed
through an exit channel back to the sump. The tailwater elevation in the
lower end of the model was regulated by means of an adjustable tailgate.
Steel rails, set to grade along either side of the model, provided a
reference plane for the use of measuring devices. Water-surface eleva
tions were measured both by means of portable point gages (mounted on an
aluminum beam supported by the steel rails) and by means of piezometers.
Piezometers were also used to measure pressures on the spillway crest and
chute. Velocities were measured by means of pitot tubes. Soundings over
the sand bed below the stilling basin were taken with a portable rod.
![Page 15: MODEL STUDY OF SPILLWAY ENID DAM, YOCONA RIVER … · The model study of the spillway for Enid Dam, proposed for con struction on the Yocona River in Mississippi, was concerned with](https://reader034.fdocuments.us/reader034/viewer/2022042209/5eac857b9c764034935bb6cc/html5/thumbnails/15.jpg)
ll
Method of Operation
16. To accomplish the purpose of the model study, it was necessary
to conduct tests which involved co~sideration of (a) relation of pool
elevation to discharge, (b) water-surface profiles over the spillway and
through the stilling basin and exit channel, (c) magnitude of pressures
on the spillway crest and chute, (d) depth and location of scour below
the stilling basin, (e) magnitude and distribution of velocities in the
stilling basin and exit channel, and (f) energy-dissipating characteris
tics of the stilling basin as observed in the model. Methods used in
calibrating the spillway, conducting scour tests, and maintaining tail
water depths are described in the paragraphs which follow.
Spillway calibration
17. The relation of pool elevation in the reservoir to discharge
over the spillway was determined in increments from low flows to the
maximum flow. Pool elevation for the spillway calibration was deter
mined for each discharge by means of a hook gage used in conjunction
with a piezometer gage located in the approach channel.
Scour downstream from stilling basin
18. Prior to conducting scour.tests, the bed of the exit channel
downstream from the stilling basin was molded flat in sand to elevation
190 and the sides of the exit channel were molded to a l-on-2 slope. To
obtain the required flow conditions, the sand bed was first flooded to
prevent unnatural erosion before stable flow conditions were reached.
The desired discharge, measured through the venturi meter, was then
![Page 16: MODEL STUDY OF SPILLWAY ENID DAM, YOCONA RIVER … · The model study of the spillway for Enid Dam, proposed for con struction on the Yocona River in Mississippi, was concerned with](https://reader034.fdocuments.us/reader034/viewer/2022042209/5eac857b9c764034935bb6cc/html5/thumbnails/16.jpg)
12
introduced into the model. As flow over the spillway becrune stabilized,
the tailgate was adjusted to obtain the required tailwater elevation.
Each scour test lasted one hour, during which time the sand bed became
relatively stable, and all data pertaining to basin action were recorded.
At the conclusion of each test, the exit area was drained and the sand
bed was -cross-sectioned.
Tailwater
19. Desired tailwater elevations were maintained by means of an
adjustable tailgate, and were determined from the approximate maximum
and minimum tailwater curves shown on plate 8, furnished by the Office
of the President, Mississippi River Commission. The preparation of a
maximum and minimum tailwater curve was necessary due to the fact that
the design called for excavation of a pilot channel below the spillway,
and contemplated the enlargement of this channel by erosion. Maximum
tailwater elevations were used in only a few tests, such as those made
to determine submergence of the hydraulic jump. The importance of
effective stilling action at the shallower depths indicated the advisa
bility of conducting the detailed tests with minimum tailwater
elevations.
Flow characteristics
20. In order, to establish the general hydraulic performance of
the stilling ba:3in .and its effect on flow conditions in the exit area,
observation tests were made of the energy-dissipating characteristics
of each of the stilling-basin designs investigated. These observations
were supported by photographs.
![Page 17: MODEL STUDY OF SPILLWAY ENID DAM, YOCONA RIVER … · The model study of the spillway for Enid Dam, proposed for con struction on the Yocona River in Mississippi, was concerned with](https://reader034.fdocuments.us/reader034/viewer/2022042209/5eac857b9c764034935bb6cc/html5/thumbnails/17.jpg)
13
PART IV: NARRATIVE OF TESTS
21. Initial model tests were conducted upon tpe spillway as orig-
inally designed. Details of the original design are as shown by figure
2 and plate l. When all aspects pf the original design had been inves-
tigated, tests were conducted of various alterations to spillway elements
as follows:
a. Preliminary observation tests of many alterations were first conducted to select designs worthy of further investigation.
b. Detailed tests were conducted upon those alterations which effected some improvement on the original design as revealed during preliminary observation tests. The detailed tests involved measurement of water~surface profiles, scour, and velocities in the stilling basin and exit channel.
22. The ma,jor portion of the testing program concerned experiments
on alternate designs for the approach walls and the stilling basin. In
presenting the results of the tests, test data are not given according
to the chronological order in which the tests were conducted. Instead,
each element of the spillway is considered in turn, and all tests con-
ducted thereon are described in detail.
Tests of Approach Channel
Description -- original design
23. The approach channel as originally designed (see figure 2 and
plate 2) was flared in plan and had a moderate adverse slope approaching .
the weir section. The bed of the channel and the side walls were paved
for a distance of 246 ft upstream from the spillway crest. In the paved
![Page 18: MODEL STUDY OF SPILLWAY ENID DAM, YOCONA RIVER … · The model study of the spillway for Enid Dam, proposed for con struction on the Yocona River in Mississippi, was concerned with](https://reader034.fdocuments.us/reader034/viewer/2022042209/5eac857b9c764034935bb6cc/html5/thumbnails/18.jpg)
14
portion of the channel, a bottom width of 200 ft was maintained. The
slope of the side walls varied from l on 3 in the flared portion of the
approach channel to l on 2 at a distance of 130.5 ft upstream from the
spillway crest. The l-on-2 sloping side walls of the approach channel
extended 9.9 ft downstream from the crest, where they intersected the
1-on-2.68 sloping walls of the spillway chute.
Results -- original design
24. Flow conditions on the spillway chute were unsatisfactory
because of the sharp intersection of the approach and chute walls. The
intersection immediately downstream from the crest caused s~anding waves
on either side of the chute which extended into the stilling basin.
These standing waves are shown in figure 3 for two conditions of dis
charge. The flow converged toward the center of the basin at both high
and low discharges. Bottom velocities measured throughout the approach
area are shown on plate 3. The highest velocity recorded was 9 ft per
sec, measured 45 ft upstream from the spillway crest.
Description -- alternate approach-chanhel walls (types A and B)
25. Approach-channel wall designs, designated as types A and B,
involved alterations to eliminate the waves on the chute caused by the
intersection of approach-channel and chute walls. These alternate types
of approach-channel walls were formed by extending the chute walls of
the original design upstream until they in~ersected the approach-channel
walls at, or upstream from, the spillway crest. The difference between
types A an.d B designs (see figure 4 and plate 2) was the manner in which
the transition from approach-chan~el to chute walls was accomplished.
![Page 19: MODEL STUDY OF SPILLWAY ENID DAM, YOCONA RIVER … · The model study of the spillway for Enid Dam, proposed for con struction on the Yocona River in Mississippi, was concerned with](https://reader034.fdocuments.us/reader034/viewer/2022042209/5eac857b9c764034935bb6cc/html5/thumbnails/19.jpg)
15
Discharge 50,000 cfs
Discharge 25,000 cfs
Figure 3. ?low conditions with approach-channel walls as originally designed
![Page 20: MODEL STUDY OF SPILLWAY ENID DAM, YOCONA RIVER … · The model study of the spillway for Enid Dam, proposed for con struction on the Yocona River in Mississippi, was concerned with](https://reader034.fdocuments.us/reader034/viewer/2022042209/5eac857b9c764034935bb6cc/html5/thumbnails/20.jpg)
16
Type A
Type B
Fi gure 4. Alternate designs f or approach- channel walls
![Page 21: MODEL STUDY OF SPILLWAY ENID DAM, YOCONA RIVER … · The model study of the spillway for Enid Dam, proposed for con struction on the Yocona River in Mississippi, was concerned with](https://reader034.fdocuments.us/reader034/viewer/2022042209/5eac857b9c764034935bb6cc/html5/thumbnails/21.jpg)
Type A walls . Discharge 50,000 cfs Type A walls. Discharge 25,000 cfs
Type B walls . Discharge 50,000 cfs Type B walls. Discharge 25,000 cfs
Figure 5. Flow conditions with alternate designs for approach-channel walls
![Page 22: MODEL STUDY OF SPILLWAY ENID DAM, YOCONA RIVER … · The model study of the spillway for Enid Dam, proposed for con struction on the Yocona River in Mississippi, was concerned with](https://reader034.fdocuments.us/reader034/viewer/2022042209/5eac857b9c764034935bb6cc/html5/thumbnails/22.jpg)
18
Immediately upstream from the weir section a portion of the approach-
channel wall in each design was made vertical in order to maintain the
200-ft width of spillway and the slope of the side walls.
Results -- alternate approach-channel walls (types A and B)
26. Figure 5 indicates that the types A and B wall revisions
accomplished the desired results at both high and low discharges, in
that the waves on the spillway chute were eliminated and the flow was
smooth and uniform over the crest and chute. Both types of walls are
about equally efficient; the choice as to which type is preferable may
be based upon their relative costs. Bottom velocities measured in the
approach channel with the types A and B walls installed are shown on
plate 3. Attention is invited to the fact that bottom velocities
recorded with these designs were as high as 12 ft per sec, whereas
velocities with the original design did not exceed 9 ft per sec.
Revision of the walls also decreased the effective spillway width, but,
as discussed in paragraph 29, the discharge at maximum pool level still
exceeded the computed design discharge.
Tests of Spillway Weir
Description -- original design~c
27. The details of the spillway crest as originally designed are
shown on plate 4. It is to be noted that the upstream face of the weir
crest has a slope of l on l from its intersection with the adverse slopo
~~ Information obtained from "Analysis of Desi~:;n, Enid Reservoir, Yocona River, Nississippi. 11
![Page 23: MODEL STUDY OF SPILLWAY ENID DAM, YOCONA RIVER … · The model study of the spillway for Enid Dam, proposed for con struction on the Yocona River in Mississippi, was concerned with](https://reader034.fdocuments.us/reader034/viewer/2022042209/5eac857b9c764034935bb6cc/html5/thumbnails/23.jpg)
19
of the approach channel at station 99 T 87.93 (elevation 258) to a point
of tangency with a circular curve having a radius of 5 ft,. which in turn
is tangent at the crest (elevation 268) to a parabolic, curve with equa
tion x2 34.75Y, where X and Y are coordinates referred to the
crest as an origin. This parabolic curve is based on the equation
x2 = 2.17 HY, where H is the design head (16 ft) necessary to dis
charge 49,700 cfs. The parabolic curve of the crest extends downstream
to the ·point where it becomes tangent to the l-on-3 slope of the chute
at elevation 267.04. In the determination of discharge capacity, the
coefficients used were assumed equal to those of a weir having the
Creager profile with an upstream slope of l on l. The model investiga-
tion of the spillway weir comprised (a) determination of the pool-
elevation vs discharge relation, and (b) measurement of water-surface
profiles and pressures. Although no alterations were made in the shape
of the weir cross section during the course of the model study, several
tests were conducted wherein the transverse axis of the weir was curved
horizontally. These latter tests are discussed in paragraphs 54 and 55.
Results -- original design
28. Spillway calibration. Reference is made to plate 5, which
shows the head-discharge relation for the original spillway design and
the effect of the types A and B approach-wall modifications on this
relation. These data indicate that the head-discharge relation as com-
puted is not in close agreement with the relation determined from the
model. At a pool elevation of 283.4 the model indicated that a dis-
charge of 63,000 cfs could be passed, whereas computations indicated a
discharge of only 49,700 cfs at a pool elevation of 284. The discrepancy
![Page 24: MODEL STUDY OF SPILLWAY ENID DAM, YOCONA RIVER … · The model study of the spillway for Enid Dam, proposed for con struction on the Yocona River in Mississippi, was concerned with](https://reader034.fdocuments.us/reader034/viewer/2022042209/5eac857b9c764034935bb6cc/html5/thumbnails/24.jpg)
20
between model and computed results is attributed to the fact that the
computed results were based on a 200-ft rectangular weir instead of the
existing 237-ft trapezoidal weir.
29. Head-discharge relationships with the alternate approach
channel walls are in close agreement with each other, although the
rating curves for the alternate approaches show lesser discharges at
equivalent heads than the rating curve for the original approach-channel
wall design. This again is the result of a change in the cross
sectional area at the crest by variation in wall alignment and slopes.
Although the cross-sectional area was reduced, the discharge at maximum
pool level was still in excess of the computed discharge, being in the
range of 57,000 cfs.
30. Water-surface and pressure profiles. Only one water-surface
profile was measured over the spillway at a discharge of 63,000 cfs,
since observation of flow conditions with the original approach-channel
wall design in place had immediately indicated the necessity for
revision. This profile, shown on plate 6, indicates that the height of
the spillway walls was sufficient to confine high discharges. Pressures
were measured over the spillway crest and chute at the locations shown
on plate 7 for discharges of 63,000, 40,000, and 20,000 cfs. The magni
tude of pressures recorded is listed in table l. It will be noted that
negative pressures of -1.5 ft and -0.5 ft of water existed at piezometer
10 for discharges ~f 20,000 and 40,000 cfs, 'respectively. All other
pressures were positive. The decrease in negative pressures at piezome
ter 10 as the discharge was increased is attributed to the effect of the
conduit openings on the chute face.
![Page 25: MODEL STUDY OF SPILLWAY ENID DAM, YOCONA RIVER … · The model study of the spillway for Enid Dam, proposed for con struction on the Yocona River in Mississippi, was concerned with](https://reader034.fdocuments.us/reader034/viewer/2022042209/5eac857b9c764034935bb6cc/html5/thumbnails/25.jpg)
Tests of Conduits
31. No detailed tests of the conduits were conducted inasmuch as
it was decided by the designing engineers during the model study to
use separate outlet structures . Observation tests indicated that the
energy of flow from the conduits would be satisfactorily dissipated by
almost any of the basin designs desc ribed in later paragraphs. Figure 6
shows a flow of 3500 cfs being dischar ged from the twin conduits. The
effect of the conduit outlet portals on spillway flow is sho\m in figure
3, where it may be seen
that at low flows the exit
portal3 caused so.te dis
turbance of flow con
ditions. As the discharge
increased, however, this
disturbance became less
apparent . Figure 6. Fl ow t hrough conduits
Tests of Stilling Basin
32. The proposed stilling basin was of the hydraulic-j~~p type
with the apron placed 2.0 ft above the depth theoretically required for
good jump action at the maxirnLm computed discharge of about 50,000 cfs.
Inasmuch as little data were available concerning the effect of a
trapezoidal-shaped channel on jump- action, the investigation of stilling
basin performance became the most important phase of the model study.
The use of a trapezoidal- shaped cnute and basin was under consideration
21
![Page 26: MODEL STUDY OF SPILLWAY ENID DAM, YOCONA RIVER … · The model study of the spillway for Enid Dam, proposed for con struction on the Yocona River in Mississippi, was concerned with](https://reader034.fdocuments.us/reader034/viewer/2022042209/5eac857b9c764034935bb6cc/html5/thumbnails/26.jpg)
22
at the time of initiation of the model study because of the saving in re-
inforcing steel which would be effected. This saving was desirable because
of the cost involved and also because materials were difficult to procure.
Instead of restraining the adjacent earth cuts by means of heavy, rein-
forced, gravity-type vertical walls, it was planned that the surface to be
lined would be graded to·slopes that would be stable without reliance for
stability upon the concrete lining.
33. The first tests of the stilling basin as originally designed in-
dicated that it would be inadequate as a means of dissipating the energy
of flow from the spillway. In order to arrive quickly at a satisfactory
stilling-basin design and obviate the laborious process of securing data
on designs not worthy of extensive investigation, a series of observation ~
tests was conducted to restrict the field of testing to the more effective
basins. Only photographic data are presented on those designs which in-
dicated no improvement. Table 2 contains a detailed description of all
the stilling-basin designs investigated during the course of the study.
34. During the testing program the maximum discharge for testing
was changed several times. For tests of the original and type l designs
a discharge of 63,00P cfs was used since that was the spillway capacity
near maximum pool level. During tests of the types 2-26 design stilling
basins, the type B approach walls were installed, reducing the capacity
to about 53,800 cfs. Consequently 53,800 cfs represented the maximum
' discharge for tests of these basins. The types 27 and 28 designs both
involved shorter'cre;t lengths which reduced capacity flow of these two
designs to 51,800 and 40,600 cfs, respectively. For tests of the types
29-38 designs the pool level was disregarded and a flow of 50,000 cfs
![Page 27: MODEL STUDY OF SPILLWAY ENID DAM, YOCONA RIVER … · The model study of the spillway for Enid Dam, proposed for con struction on the Yocona River in Mississippi, was concerned with](https://reader034.fdocuments.us/reader034/viewer/2022042209/5eac857b9c764034935bb6cc/html5/thumbnails/27.jpg)
23
was used, closely simulating the maximum design outflow of 49,700 cfs
desired. In comparing the results of the stilling-basin tests, con-, . sideration should be given to the discharge involved ~n each case.
Description -- original design
35. The stilling basin as originally designed consisted of a 360-
ft horizontal apron located at elevation 190. No baffle piers or end
sill were placed on the apron, although it was anticipated that their
need would be demonstrated by the model tests. Flow through the still-
ing basin was confined by l-on-2 sloping side walls. The bottom width
of the stilling basin was 200 ft, whereas at the minimum tailwater
elevation of 220.4 ft for 50,000 cfs the top width of the basin was
322.4 ft. Investigation of the original basin design was confined to I
observing and photographing flow conditions.
Results -- original design
36. Observation of flow conditions in the stilling basin, as
originally designed, revealed that basin action was unsatisfactory for
all discharges. Figure 7 demonstrates that flow from the chute at both
high and low discharges was concentrated in a narrow portion of the
basin width as a result of the large eddies formed at the junction of the
chute and stilling-basin walls. Although the walls of the chute and
stilling basin were on the same slope (l on 2 ) and the toes of the chute
and basin side-walls were on a line parallel with the centerline of the
spillway, the junction of the sloping chute and horizontal basin formed
a reentrant angle in the wall on either side (see figure 2). This
reentrant angle caused eddies which crowded the chute flow into a small
![Page 28: MODEL STUDY OF SPILLWAY ENID DAM, YOCONA RIVER … · The model study of the spillway for Enid Dam, proposed for con struction on the Yocona River in Mississippi, was concerned with](https://reader034.fdocuments.us/reader034/viewer/2022042209/5eac857b9c764034935bb6cc/html5/thumbnails/28.jpg)
Original design. Discharge 63,000 cfs; tailwater elev. 223.8 Discharge 20,000 cfs; tailwater elev. 215.0
Type 1 design. Discharge 63,000 cfs; tailwater elev. 223.8 Discharge 20,000 cfs; tai1water elev. 215.0
Figure 7. Hydraulic performance of original and type 1 basin designs at high and low flows ,
![Page 29: MODEL STUDY OF SPILLWAY ENID DAM, YOCONA RIVER … · The model study of the spillway for Enid Dam, proposed for con struction on the Yocona River in Mississippi, was concerned with](https://reader034.fdocuments.us/reader034/viewer/2022042209/5eac857b9c764034935bb6cc/html5/thumbnails/29.jpg)
portion of the basin width. Although the flow from the chute into the
basin was confined to a small portion of the ba3in width, the location
of the confined path of flow varied at intervals from the left wall of
the basin to the right wall and then again to the left. Even with an
apron length of 360 ft the exit channel was subjected to high-velocity
currents which extended through the basin and attacked the unpaved
portion of the exit channel.
Description -- type l design
25
37. In an attempt to improve the performance of the basin as.
originally designed, dentates were added at the toe of the chute. These
dentates were 10 ft high, 10 ft wide, 45 ft long, and were spaced at
about 10 ft. Those near the side walls were placed at a slight angle to
the spillway centerline in an attempt to force the greater percentage of
flow along the basin walls and thus destroy or reduce the side eddies at
the junction of the chute and basin walls.
Results -- type l design
38. As shown in figure 7 the addition of the 10-ft dentates at
the toe of the chute aided only slightly in improving flow distribution
in the basin. At high discharges the flow from the chute forced the
tailwater downstream, exposing part of the dentates and thus permitting
them to deflect part of the chute flow. At low discharges, however, the
dentates were entirely submerged and had no apparent effect on flow.
For all .conditions of discharge, flow was concentrated in a small
portion of the basin with strong upstream currents in the areas adjacent
to the side walls.
![Page 30: MODEL STUDY OF SPILLWAY ENID DAM, YOCONA RIVER … · The model study of the spillway for Enid Dam, proposed for con struction on the Yocona River in Mississippi, was concerned with](https://reader034.fdocuments.us/reader034/viewer/2022042209/5eac857b9c764034935bb6cc/html5/thumbnails/30.jpg)
26
Description -- types 2-5 designs
39. Since the dentates alone were unsuccessful in improving flow
conditions in the basin, the types 2-5 designs incorporated more exten
sive alterations. In an effort to eliminate the eddies, the stilling
basin was narrowed to such an extent that the path of flow along the
stilling-basin walls was an extension of the path of flow adjacent to
the chute walls. This was accomplished by reducing the apron width at
the base of the side walls from 200 to 84 ft and placing transition
walls from the chute to the basin. The reduced basin width was common
to the types 2-5 designs, while the addition of baffle piers, end sill,
dentates, and a solid stepped bucket formed the various other alter
at~ons investigated in these designs as illustrated by figure 8.
Details of the designs are listed in table 2.
Results -- types 2-5 desisns
40. Observation of flow conditions (see figure 9) with the types
2-5 designs in place revealed unsatisfactory basin performance for each
design at high discharges. In the type 2 design the reduction in basin
width caused excessive turbulence in that area, and the partial jump
which formed over the apron was almost forced from the basin unless
baffle piers and an end sill were used as in the type 3 design. These
alterations eliminated some of the turbulence, but basin conditions were
still poor. The addition of dentates or a solid stepped bucket at the
toe of the chute (types 4 and 5 designs) caused the jump to be swept
into the exit channel and resulted in very unstable basin action. At
low discharges, flow conditions with the types 2, 3 and 4 designs were
![Page 31: MODEL STUDY OF SPILLWAY ENID DAM, YOCONA RIVER … · The model study of the spillway for Enid Dam, proposed for con struction on the Yocona River in Mississippi, was concerned with](https://reader034.fdocuments.us/reader034/viewer/2022042209/5eac857b9c764034935bb6cc/html5/thumbnails/31.jpg)
Type 2 design Type 3 design
~ ./
Type 4 design Type 5 design
Figure 8. Basin designs tested with apron narrowed to 84 ft (types 2-5)
![Page 32: MODEL STUDY OF SPILLWAY ENID DAM, YOCONA RIVER … · The model study of the spillway for Enid Dam, proposed for con struction on the Yocona River in Mississippi, was concerned with](https://reader034.fdocuments.us/reader034/viewer/2022042209/5eac857b9c764034935bb6cc/html5/thumbnails/32.jpg)
Type 2 design Type 3 design
TYPe 4 design Type 5 design
Figure 9. Hydraulic performance of types 2-5 basins at high flows. Discharge 53,800 cfs; tailwater 221.7
![Page 33: MODEL STUDY OF SPILLWAY ENID DAM, YOCONA RIVER … · The model study of the spillway for Enid Dam, proposed for con struction on the Yocona River in Mississippi, was concerned with](https://reader034.fdocuments.us/reader034/viewer/2022042209/5eac857b9c764034935bb6cc/html5/thumbnails/33.jpg)
Type 2 design Type 3 design
Type 4 design Type 5 design
Figure 10. Hydraulic performance of types 2-5 basins at low flows. Discharge 25,000 cfs; tailwater 216.0
![Page 34: MODEL STUDY OF SPILLWAY ENID DAM, YOCONA RIVER … · The model study of the spillway for Enid Dam, proposed for con struction on the Yocona River in Mississippi, was concerned with](https://reader034.fdocuments.us/reader034/viewer/2022042209/5eac857b9c764034935bb6cc/html5/thumbnails/34.jpg)
.30
improved in that a fair hydraulic jump formed within the confines of the
basin, as shown in figure 10. The use of a solid stepped bucket of the
type 5 design, however, prevented the formation of a jump at low flows.
Although basin action was satisfactory at low discharges for types 2, .3
and 4 designs, the unsatisfactory performance of all four basins at high
discharges eliminated them from f~rther consideration.
Description -- types 6-11 designs
41. Inasmuch as tests of the types 2-5 designs had demonstrated
that the 84-ft basin width was too narrow, this width was increased to
144 ft and basin elements similar to those tested in the types 2-5
designs were investigated with the new basin width. Details of these
designs are listed in table 2 and illustrated by figure 11.
Results ~- types 6-11 designs
42. Flow conditions with the types 6-11 designs are shown by fig~
ures 12-13. It was observed that flow conditions with the types 6 and 7
designs installed were similar to those for the type 5 design previously
discussed in that the 10-ft step or drop at the toe of the chute caused
the jump to be swept from the stilling basin at all discharges. Of the
designs tested in this group the types 8 and 11 induced the most satis-
factory conditions. At high discharges the flow was violent and un-
stable; at low flows, although the 10-ft dentates of type 8, and the 5-
ft step of type 11 design did not entirely eliminate the side eddies at
the chute and basin wall junction, the eddies were reduced in size.
Comparison of flow conditionsof the type 8 and 11 designs with those of
the types 9 and 10 designs clearly indicate the need for baffle piers,
![Page 35: MODEL STUDY OF SPILLWAY ENID DAM, YOCONA RIVER … · The model study of the spillway for Enid Dam, proposed for con struction on the Yocona River in Mississippi, was concerned with](https://reader034.fdocuments.us/reader034/viewer/2022042209/5eac857b9c764034935bb6cc/html5/thumbnails/35.jpg)
31
Type 6 design Type 7 design
Type S design Type 9 design
Type 10 design Type 11 design
Figure 11. Basin designs tested with apron width of 144 ft (types 6- 11)
![Page 36: MODEL STUDY OF SPILLWAY ENID DAM, YOCONA RIVER … · The model study of the spillway for Enid Dam, proposed for con struction on the Yocona River in Mississippi, was concerned with](https://reader034.fdocuments.us/reader034/viewer/2022042209/5eac857b9c764034935bb6cc/html5/thumbnails/36.jpg)
32
Type 6 design Type 7 design
Type 8 design Type 9 design
Type 10 design Type 11 design
Discharge 53,800 cfs; tai1~ater elevation 221 . 7 Figure 12. Hydrauli.c performance of t ypes 6- 11 basins at high flows.
![Page 37: MODEL STUDY OF SPILLWAY ENID DAM, YOCONA RIVER … · The model study of the spillway for Enid Dam, proposed for con struction on the Yocona River in Mississippi, was concerned with](https://reader034.fdocuments.us/reader034/viewer/2022042209/5eac857b9c764034935bb6cc/html5/thumbnails/37.jpg)
33
Type 6 design Type 7 design
..
Type 8 design Type 9 design
Type 10 design Type 11 design
D~scharge 25,000 cfs; tailwater elevation 216.0 Figure 13. Hydraulic performance of types 6- 11 basins at low flows
![Page 38: MODEL STUDY OF SPILLWAY ENID DAM, YOCONA RIVER … · The model study of the spillway for Enid Dam, proposed for con struction on the Yocona River in Mississippi, was concerned with](https://reader034.fdocuments.us/reader034/viewer/2022042209/5eac857b9c764034935bb6cc/html5/thumbnails/38.jpg)
34
end sill, and some additional structures at the toe of the chute to aid
in spreading the flow across the full width of the basin. Analysis of
all previous observation tests confirmed this conclusion. With the type
11 basin installed and at a discharge of 53,800 cfs, velocity distri
butions were measured at the end sill to determine whether any high con
centrations of flow existed over the end sill. The bottom velocities
over the end sill ,were evenly distributed and in the range of 2 to 4 ft
per sec (see plate 9).
Description -- type 12 design
43. The type 12 design incorporated the structural features which
were shown by previous observations to be needed at the toe of the chute
to spread the flow in the basin, and in addition included a new design
for the face of the chute. The basin design consisted of the originally
favored 200-ft width, a 150-ft length, two rows of baffle piers 8 and 12
ft in height, respectively, and a 5-ft end sill. The chute had a slope
of 1 on 4 from the invert of the conduit exit portals to a lO-ft-high
stepped bucket at its toe, while the original chute slop~ of 1 on 3 was
maintained adjacent to the chute walls, for~ng a 15-ft wide depressed
channel on each side of the chute. The purpose of the channels was to
increase the amount of flow adjacent to each wall in an effort to
destroy the eddies previously described.
Results -- type 12 design
44, The type 12 design was unsuccessful in accomplishing its
purpose due to the fact that the depth of the small channel adjacent to
each side wall was insufficient to pass the amount of flow necessary to
![Page 39: MODEL STUDY OF SPILLWAY ENID DAM, YOCONA RIVER … · The model study of the spillway for Enid Dam, proposed for con struction on the Yocona River in Mississippi, was concerned with](https://reader034.fdocuments.us/reader034/viewer/2022042209/5eac857b9c764034935bb6cc/html5/thumbnails/39.jpg)
35
eliminate or reduce eddy action within the basin .
Description -- tyPes 13- 15 designs
45. In the types 13 , 14 and 15 stilling-basin designs, the use of
a chute with an arched floor surface was introduced to aid in securing
uniform flow distribution in the stilling basin. Beginning 12 ft down
stream from the spillway crest, the elevation of the chute floor at the
centerline was raised 6.7 ft for the type 13 design and 3.3 ft for the
types 14 and 15 designs. In each case the original elevation of the
chute at the side walls was maintained. The type 15 design comprised,
in addition to the arched chute, a 5- ft solid stepped sill at the toe of
the chute and a 10- ft deflector pier on either side of the chute at the
entrance to the stilling basin . In all three designs one row of 8-ft
baffle piers, one row of 12- ft baffle piers, and a 5-ft end sill were
placed on the 150-ft apron to aid in the dissipation of energy . The
basin width in each design was 200 ft. Details of the type 14 design
are shown by figure 14.
Figure 14. Type 14 design with arched chute and original basin width
![Page 40: MODEL STUDY OF SPILLWAY ENID DAM, YOCONA RIVER … · The model study of the spillway for Enid Dam, proposed for con struction on the Yocona River in Mississippi, was concerned with](https://reader034.fdocuments.us/reader034/viewer/2022042209/5eac857b9c764034935bb6cc/html5/thumbnails/40.jpg)
36
Results -- types 13-15 designs
46. The use of the arched chute of type 13 design gave excellent
flow distribution at high discharges. The eddies formerly existing at
the side walls were almost eliminated and a good jump formed over the
basin width. At low flows, however, the arched chute caused most of the
flow to be concentrated along the sides of the basin. Consequently, for
low discharges the flow in the basin was swift adjacent to the walls and
was directed upstream at the center of the basin. Since unfavorable
conditions existed at normal flows, it was decided that the centerline
of the chute had been elevated too much. This decision was confirmed by
the improved conditions which prevailed when the type 14 design, with
its 3.3 ft rise at the centerline, was tested. As shown by figure 15,
the eddies adjacent to the walls, though not eliminated entirely, were
greatly reduced in size and did not interfere appreciably with jump
action. Velocities measured over a cross section of the basin at the
end sill indicated fairly uniform flow distribution (see plate 9); the
maximum bottom velocity recorded over the end sill was only 6 ft per
sec. The solid stepped sill and deflectors of the type 15 basin were
intended to eliminate the small eddies still existing with the type 14
design without interfering with jump action. Flow conditions were not
enough improved, however, to warrant construction of the extra sill and
deflectors. The most important fact demonstrated by tests of the types
13-15 designs was that good basin conditions could be obtained through
use of an arched chute floor. The results of tests with the type 14
design indicated it to be the best of the first fifteen designs
investigated.
![Page 41: MODEL STUDY OF SPILLWAY ENID DAM, YOCONA RIVER … · The model study of the spillway for Enid Dam, proposed for con struction on the Yocona River in Mississippi, was concerned with](https://reader034.fdocuments.us/reader034/viewer/2022042209/5eac857b9c764034935bb6cc/html5/thumbnails/41.jpg)
37
Discharge 53,800 cfs; tailwater elevation 221.7
Discharge 25,000 cfs ; tailwater elevation 216.0
Figure 15. Hydraulic performance of type 14 basin at high and low flows
![Page 42: MODEL STUDY OF SPILLWAY ENID DAM, YOCONA RIVER … · The model study of the spillway for Enid Dam, proposed for con struction on the Yocona River in Mississippi, was concerned with](https://reader034.fdocuments.us/reader034/viewer/2022042209/5eac857b9c764034935bb6cc/html5/thumbnails/42.jpg)
38
Description ~- type 16 design
47. The type 16 design was similar to the type 15 design except
that the chute was restored to its original plane surface. The purpose
of tests of the type 16 design was to investigate the possibility of
spreading the chute flow entirely by structures located on the chute.
Therefore, in addition to the 8- and 12-ft baffle piers and the 5-ft
end sill on the horizontal apron, lO-ft triangular deflector blocks7~
were placed on the chute immediately upstream from its junction with
the basin.
Results -- type 16 design
48. The type 16 design gave fair basin action at all discharges.
The flow striking the large blocks was deflected at an angle directly
into the areas fo~nerly occupied by eddies. The direction of flow
destroyed the eddy action and permitted a good jump to form. The only
undesirable feature of the design was that the high-velocity flow
adjacent to the side walls tended to extend into the exit channel.
Description -- types 17-27 designs
49. In view of the fact that previous tests had indicated that,
with a trapezoidal-shaped basin, arching of the chute surface or use of
high deflector blocks on the chute were the only improvements worthy of
further consideration, it was thought desirable to investigate a few
designs with vertical basin walls to obtain comparative data on the
7~ Deflectors of this type were used on all basin. designs incorporating deflectors. For details see figure 19 and plate 32.
![Page 43: MODEL STUDY OF SPILLWAY ENID DAM, YOCONA RIVER … · The model study of the spillway for Enid Dam, proposed for con struction on the Yocona River in Mississippi, was concerned with](https://reader034.fdocuments.us/reader034/viewer/2022042209/5eac857b9c764034935bb6cc/html5/thumbnails/43.jpg)
relative effectiveness of trapezoidal- and vertical-shaped stilling
basins.
39
50. Accordingly, the types 17~27 designs consis~ed of vertical
basin walls, 150-ft apron length, and a 200-ft basin width, with differ
ences in the various designs involving mainly the height and location of
baffle piers. In all designs of this group, except the type 27 design,
the chute walls retained their original 1-on-2 slope with a transition
to vertical walls provided at the junction of the chute and stilling
basin. In the type 27 design, vertical walls were maintained for the
full spillway and basin length in order to compare the effects of
vertical and sloping chute walls. Reference is made to table 2, which
lists the detailed dimensions of each basin element. Reference is also
made to paragraphs 68 and 69 for discussion of two additional vertical
wall type stilling basins.
Results -- types 17-27 designs
51. As shown by figure 16, the use of vertical stilling-basin
walls improved flow conditions within the basin more than the previously
observed trapezoidal-shaped basin. Moreover, the sloped chute walls
with a transition to vertical basin walls were as efficient in providing
good basin conditions as were the vertical walls throughout the chute
and basin (type 27 design). The use of vertical chute walls in the
vicinity of the spillway crest s~ction (type 27 design) resulted in a
reduction in effective crest length, and a slight decrease in spillway
discharge. Observation tests conducted with the type 18 design clearly
indicated that the absence of baffle piers caused an unstable condition,
![Page 44: MODEL STUDY OF SPILLWAY ENID DAM, YOCONA RIVER … · The model study of the spillway for Enid Dam, proposed for con struction on the Yocona River in Mississippi, was concerned with](https://reader034.fdocuments.us/reader034/viewer/2022042209/5eac857b9c764034935bb6cc/html5/thumbnails/44.jpg)
Type 24 design. Discharge 53,800 cfs; tailwater elev. 221.7 Discharge 25,000 cfs; tailwater elev. 216.0
Type 27 design. Discharge 51,800 cfs; tailwater elev. 221.7 Discharge 25 , 000 cfs; tailwater elev. 216.0
Figure 16. Hydraulic perforn~nce of types 24 and 27 basins at high and low flows
![Page 45: MODEL STUDY OF SPILLWAY ENID DAM, YOCONA RIVER … · The model study of the spillway for Enid Dam, proposed for con struction on the Yocona River in Mississippi, was concerned with](https://reader034.fdocuments.us/reader034/viewer/2022042209/5eac857b9c764034935bb6cc/html5/thumbnails/45.jpg)
bordering on spray action, to exist in the basin. The addition of
baffle piers stabilized jump action, although when placed near the toe
of the chute, the piers were subjected to considerable impact. Water
surface profiles recorded on the centerline of the spillway with the
type 25 design installed indicated that flow over the spillway was
smooth and a good hydraulic jump was formed in the stilling basin
(see plates 12 and 13). Velocity distributions measured over the end
sill with the type 25 d< sign installed indicated an even distribution
of flow in the exit channel; the maximum bottom velo~ity recorded over
the sill was 10ft per sec (see plate 9).
41
52. Scour tests conducted at a discharge of 53,800 cfs indicated
that placing of the baffle piers farther downstream in the type 25
design improved scour conditions over those existing with the type 24
design (see plates ll and 14). Tests of basin action with the end sill
and baffle piers r~moved (type 26 design) clearly indicated the need for
these elements, as the jump was formed 90 ft below the toe of the chute
and extended into the exit channel, thereby causing excessive scour (see
plate 17).
53. Of the vertical-wall type designs tested, the best all-round
basin performance was secured with the type 25 design. The 6-ft baffle
piers were placed far enough do~1stream from the toe of the chute to be
cushioned against excessive impact forces, yet they aided in stabilizing
the jump and deflecting high-velocity bottom currents upward away from
the bed of the exit channel. Bottom velocities measured in the exit
channel, and shown on plates 15 and 16 for discharges of 53,800 cfs and
25,000 cfs, were negligible.
![Page 46: MODEL STUDY OF SPILLWAY ENID DAM, YOCONA RIVER … · The model study of the spillway for Enid Dam, proposed for con struction on the Yocona River in Mississippi, was concerned with](https://reader034.fdocuments.us/reader034/viewer/2022042209/5eac857b9c764034935bb6cc/html5/thumbnails/46.jpg)
42
Descriotion -- type 28 design
54. The type 28 design was ceve~oped by combining several al~er-
ations suggested by the Harza Eng~~eerir..g Co.~pany . Deta..:.ls of this
desigr. are shown on pldte 18. In o~der to spread the flow, the floor of
the c.r.u.te was r:ot only arcned, being 3.3 ft higher on the center_lne,
but was also flared in plan. The c~u~e started from a concave- shaped
crest 160 ft in 'Nidth, and flared to 200 ft nco.r its intersection v:ith
the uasin, then returned to a 160-ft basin ,,ridth. J\S suggested by tne
Harza Engineerinr Comrany, the basin v;as 265 ft ..... ong a .. d contai!1ed two
ro-v:s of 6- ft baffle piers and a 5- ft end sill. The 160-ft .
concave-
shaped crest was designated as the type C approach.
Discharge 40,600 cfs; tailwater elevation 218.3
Figure 17. Hydraulic performance of type 28 basin at high flow
![Page 47: MODEL STUDY OF SPILLWAY ENID DAM, YOCONA RIVER … · The model study of the spillway for Enid Dam, proposed for con struction on the Yocona River in Mississippi, was concerned with](https://reader034.fdocuments.us/reader034/viewer/2022042209/5eac857b9c764034935bb6cc/html5/thumbnails/47.jpg)
43
Results -- type 28 design
55. Flow conditions observed with the type 28 design installed
were not as good as those observed with other type designs. The maximum
discharge that could be passed over the narrowed crest was only about
40,600 cfs at the maximum pool level, which is less than the discharge
of 49,700 cfs desired. The head-discharge curve established for the
type C approach is plotted on plate 5. At the maximum discharge of
40,600 cfs, flow tended to cling to the left portion of the basin with' a
strong upstream current adjacent to the right wall (see figure 17). The
velocity distribution measured in a vertical plane over the end sill
indicated that the highest velocities were located near the left wall
and reached a magnitude of 8ft per sec over the end sill (see plate 9).
Description -- types 29-33 designs
56. Inasmuch as the type 14 design with its arched chute as
described in paragraphs 45 and 46 had performed so well, it was decided
to study refinements in the dimensions of the various elements of this
design. The types 29-33 designs had an arched chute with a rise of 5.12
ft at the centerline sloping down to the original elevation at the sides.
The 5 .12-ft rise at the centerline v.ras selected because tests of the
type 13 design had indicated that a rise of 6.7 ft was too high for good
flow conditions at low discharges, and it was believed that the rise of
3.3 ft tested in the type 14 design was too low for best performance at
high discharges. The type 29 design included a 150-ft apron without
baffle piers, whereas in the types 30, 31, 32 and 33 designs the apron
length was 100 ft; variations consisted of no baffle piers, one row of
![Page 48: MODEL STUDY OF SPILLWAY ENID DAM, YOCONA RIVER … · The model study of the spillway for Enid Dam, proposed for con struction on the Yocona River in Mississippi, was concerned with](https://reader034.fdocuments.us/reader034/viewer/2022042209/5eac857b9c764034935bb6cc/html5/thumbnails/48.jpg)
44
8-ft baffle piers, two rows of 8-ft baffle piers, and two rows of 6-ft
baffle piers, respectively (see table 2). Details of the type 32 design
are shown by figure 18 and plate 24.
Results -- types 29-33 designs
57. Flow conditions. Flow conditions in the basins of types 29
and 30 designs were very unstable, with large eddies adjacent to each
basin wall. The addition of one row of baffle piers (type 31) improved
flow conditions, though. the piers apparently were subjected to severe
impact. It was not until the two 8-ft rows of baffle piers were added
(type 32 design) that good flow conditions were obtained (see figure 18).
At a discharge of 50_, 000 cfs the flow was distributed evenly across the
basin, forming a good jump. Although small eddies still existed at the
extremities of the jump, they were not believed to be detrimental to
basin performance. At a discharge of 25,000 cfs, jump action was good,
though not quite as good in the center portion of the basin as at
higher discharges.
58. Water-surface profiles. Water-surface profiles recorded on
the centerline of the spillway and adjacent to one of the chute walls
show the configuration of the jump in the type 32 basin. These data also
demonstrate the effect of the arched chute, in that the water-surface
level is higher in the center portion of the spillway than adjacent to
the chute walls (plates 25-26).
59. Scour. Measurements of scour with the types 29 and 30
designs installed (plates 19-22) indicated that the apron length of 150
ft used with the type 29 design offered only slightly more protection to
![Page 49: MODEL STUDY OF SPILLWAY ENID DAM, YOCONA RIVER … · The model study of the spillway for Enid Dam, proposed for con struction on the Yocona River in Mississippi, was concerned with](https://reader034.fdocuments.us/reader034/viewer/2022042209/5eac857b9c764034935bb6cc/html5/thumbnails/49.jpg)
Discharge 50,000 cfs ; tailwater elevation 220.6 Discharge 25,000 cfs; tailwater elevation 216.0
Figure 18. Elements of type 32 basin design, and hydraulic performance at high and low flows
![Page 50: MODEL STUDY OF SPILLWAY ENID DAM, YOCONA RIVER … · The model study of the spillway for Enid Dam, proposed for con struction on the Yocona River in Mississippi, was concerned with](https://reader034.fdocuments.us/reader034/viewer/2022042209/5eac857b9c764034935bb6cc/html5/thumbnails/50.jpg)
46
the bed of .the exit channel than the 100-ft apron of the type 30 design.
It was therefore decided that an apron length of 100 ft was sufficient.·
Scour data also indicated that less erosion occurred in the exit channel
for a discharge of 50,000 cfs than for a 25,000 cfs discharge. This was
due to the better flow conditions existing in the stilling basin and exit
channel at the higher discharge. Addition of one row of 8-ft baffle piers
(type 31 design) on the 100-ft apron effected a large reduction in the
amount of scour as illustrated by a comparison of plates 21 and 23. The
use of two rows of 8-ft baffle piers (type 32 design) reduced the amount
of scour still further (plates 27 and 28). As shown by plate 31, are-
duction in the height of both rows of baffle piers from 8 to 6 ft (type
33 design) resulted in a very slight increase in the depth of scour,
60. Velocities. The distribution of velocities at the end sill
for the types 29, 30 and 32 designs, is plotted on plates 9 and 10 and
indicates the necessity for baffle piers to obtain even flow distri-
bution into the exit channel. vfuen the baffle piers were omitted as in
the types 29 and 30 designs, high velocities were concentrated near the
side walls of the basin. \Vith the baffle piers of the type 32 design
installed, however, velocities were uniformly distributed across the end
sill and were small in magnitude the maximum velocity immediately
over the end sill did not exceed 8 ft per sec. Bottom velocities over
the exit area also were measured at discharges of 50,000 cfs and 25,000
cfs with the type )2 design in place. As shown by plates 29 and 30, >
velocities in the exit area ranged from 1 to 11 ft per sec at a discharge
of 50,000 cfs· and from 1 to 4 ft per sec at a discharge of 25,000 cfs.
The higher velocities were recorded adjacent to the riprapped sections
![Page 51: MODEL STUDY OF SPILLWAY ENID DAM, YOCONA RIVER … · The model study of the spillway for Enid Dam, proposed for con struction on the Yocona River in Mississippi, was concerned with](https://reader034.fdocuments.us/reader034/viewer/2022042209/5eac857b9c764034935bb6cc/html5/thumbnails/51.jpg)
on the sides of the exit channel, and were due in part to the fact that
the cross section of the exit channel was a continuation of the cross
section of the stilling basin .
Description -- type 34 design
47
61 . The type 34 design was developed as a result of observation
tests of the elements of type 16 design. In these test s the use of high
deflector blocks located on either side of the flat chute of the origi
nal design had given promise of providing good basin action . Details of
the type 34 design are shown in table 2, and by figure 19 and plate 32.
The design incorporated two 15-ft high streamlined deflector blocks on
the chute as well as two rows of 8-ft baffle piers, and a 5- ft end sill
on a 100- ft apron .
Figure 19. 15- ft deflector blocks on flat chute of type 34 design
•
![Page 52: MODEL STUDY OF SPILLWAY ENID DAM, YOCONA RIVER … · The model study of the spillway for Enid Dam, proposed for con struction on the Yocona River in Mississippi, was concerned with](https://reader034.fdocuments.us/reader034/viewer/2022042209/5eac857b9c764034935bb6cc/html5/thumbnails/52.jpg)
48
Results -- type 34 design
62. Flow conditions. Flow conditions in the type 34 basin were
satisfactory. The 15-ft deflectors were sufficiently high to deflect
enough chute discharge to break up the eddies adjacent to each basin
wall (figure 20). At a discharge of 25,000 cfs, the concentration of
flow along the basin side walls caused currents as swift as for a dis
charge of 50,000 cfs.
63. Water-surface profiles. Average water-surface profiles
measured during tests of the type 34 basin indicated that a good jump
was formed at discharges of 50,000 and 25,000 cfs (plates 33 and 34).
64. Scour. Reference is made to plates 35 and 36 showing results
of scour tests conducted for discharges of 50,000 and 25,000 cfs. Com
parison of these data with results obtained with the arched chute of the
type 32 design (plates 27 ano 28) indicates that these types were almost
equally effective in the dissipation of energy.
65. Velocities. The distribution of velocities in a vertical
range at the end sill, and the bottom velocities in the exit channel,
are shown on plates 10, 37 and 38. Bottom veloc.ities at the end sill
were evenly distributed, and did not exceed 6 ft per sec. Bottom
velocities recorded in the exit channel ranged from l to 17ft per sec
at a discharge of 50,000 cfs, and from 3 to 14 ft per sec at a discharge
of 25,000 cfs. Comparison of bottom velocities with those ob~erved in
the exit channel below the basin of type 32 design (plates 29 and 30)
indicates that type 32 is the better design, especially at the 25,000
cfs discharge.
![Page 53: MODEL STUDY OF SPILLWAY ENID DAM, YOCONA RIVER … · The model study of the spillway for Enid Dam, proposed for con struction on the Yocona River in Mississippi, was concerned with](https://reader034.fdocuments.us/reader034/viewer/2022042209/5eac857b9c764034935bb6cc/html5/thumbnails/53.jpg)
49
Discharge 50,000 cfs; tailwater elevation 220.6
Discharge 25,000 cfs; tailwater elevation 216.0
Figure 20. Hydraulic performance of type 34 basin at high and low flows
![Page 54: MODEL STUDY OF SPILLWAY ENID DAM, YOCONA RIVER … · The model study of the spillway for Enid Dam, proposed for con struction on the Yocona River in Mississippi, was concerned with](https://reader034.fdocuments.us/reader034/viewer/2022042209/5eac857b9c764034935bb6cc/html5/thumbnails/54.jpg)
50
Description -- type 35 design
66. The type 35 design is identical to the type 34 design except
that the deflector blocks were removed from the chute (table 2 and
figure 21). Tests were conducted to study the effect of removing the
deflectors.
Results -- type 35 design
67. The elimination of the deflector blocks of the type 34 design
destroyed the good basin action that had previously prevailed. Large
eddies were present at each wall and the chute flow was crowded into a
narrow portion of the basin width (figure 21). A scour test conducted
at a discharge of 50,000 cfs indicated that scour was excessive, thus
showing that the successful performance of the type 34 design was con-
tingent upon the use of the chute deflector blocks (compare plates 35
and 39).
Description -- types 36 and 37 designs
68. A detailed comparison of all test results with sloped and
vertical basin walls heretofore described indicates that, although flow
conditions in the vertical-walled basin were superior to those existing
when sloping walls were used, the amount of scour and distribution of
velocities were about the sarne. Accordingly, the types 36 and 37
designs with vertical side walls were developed for direct comparison
' with types 32 and 34 designs having sloping side walls. The types 36 . ~
and 37 designs involved an apron length of 100 ft, two rows of 8-ft
baffle piers, and a 5-ft end sill. The location and size of basin
elements were identical to those of types 32 and 34 designs. The only
![Page 55: MODEL STUDY OF SPILLWAY ENID DAM, YOCONA RIVER … · The model study of the spillway for Enid Dam, proposed for con struction on the Yocona River in Mississippi, was concerned with](https://reader034.fdocuments.us/reader034/viewer/2022042209/5eac857b9c764034935bb6cc/html5/thumbnails/55.jpg)
51
Discharge 50,000 cfs; tailwater elevation 220.6
Figure 21 Type 35 basin design, and hydraulic performance at hi@1 flows
![Page 56: MODEL STUDY OF SPILLWAY ENID DAM, YOCONA RIVER … · The model study of the spillway for Enid Dam, proposed for con struction on the Yocona River in Mississippi, was concerned with](https://reader034.fdocuments.us/reader034/viewer/2022042209/5eac857b9c764034935bb6cc/html5/thumbnails/56.jpg)
52
difference between the types 32 and 34 designs was that even distri
bution of flow into the trapezoidal-shaped stilling basin was secured by
an arched chute floor in the type 32 design, and by large deflector
blocks in the type 34 design. In the type 37 design the vertical walls
of the stilling basin were extended and rounded on a 100-ft radius,
whereas in the type 36 design the side walls were terminated at the end
sill. In each design the chute walls were on a l-on-2 slope, with a
transition from the chute to the vertical basin walls.
Results -- types 36 and 37 designs
69. Elimination of the sloping side walls of the stilling basin
permitted formation of a good hydraulic jump which was evenly dis
tributed across the basin. Flow over the end sill also appeared to be
uniformly distributed. Scour tests conducted at a discharge of 50,000
cfs with the types 36 and 37 basins in place indicated that the exten
sion and rounding of the wing walls below the end sill provided some
additional degree of protection (plates 40 and 41). Comparison of scour
results with those recorded with the type 25 (vertical wall) basin in
place (plate 14) indicates that the 50-ft reduction in basin length of
the types 36 and 37 designs had little effect. Results of scour tests
conducted with the vertical-wall type 37 basin in place (plate 41) and
with the sloping-wall basins of types 32 and 34 in place (plates 27 and
35), indicate that,no scour occurred with the trapezoidal-shaped basins
installed, and,only a slight amount occurred in the exit channel below
the types 36 and 37 basins.
![Page 57: MODEL STUDY OF SPILLWAY ENID DAM, YOCONA RIVER … · The model study of the spillway for Enid Dam, proposed for con struction on the Yocona River in Mississippi, was concerned with](https://reader034.fdocuments.us/reader034/viewer/2022042209/5eac857b9c764034935bb6cc/html5/thumbnails/57.jpg)
53
Description -- type 38 design
70. The type 38 design was evolved at the suggestion of hr. W. H.
McAlpine of the Office, Chief of Engineers, to study the effect of con
tinuing the 5-ft end sill up the l-on-2-sloping side walls of the
stilling basin. All other details of the type 38 design stilling basin
were similar to those of the type 32 design, with arched chute, dis
cussed previously.
Results -- type 38 design
71. The extension of the 5-ft end sill up the sloping side walls
of the stilling basin had no apparent effect on flow conditions within
the basin proper. However_, immediately downstream from the end sill on
the sloping side walls, small eddies formed which resulted in some
erosion; this was not present when the sill was omitted in these areas
(compare plates 42 and 43 with plates 27 and 28). Bottom velocities
measured in the exit channel were comparable to those measured below the
type 32 design. Bottom velocities adjacent to the side walls were
slightly higher with the type 38 design as a result of the reduced cross
section caused by extension of the end sill (plates 44 and 45). Hence,
it can be concluded that the extension of the sill on the sloping side
walls of the stilling basin is of no value in improving the safety of
tho structure.
Summary of Stilling-Basin Test Results
72. Observation tests conducted on the types l-16 designs indi
cated that with a trapezoidal-shaped stilling basin design, flow from
![Page 58: MODEL STUDY OF SPILLWAY ENID DAM, YOCONA RIVER … · The model study of the spillway for Enid Dam, proposed for con struction on the Yocona River in Mississippi, was concerned with](https://reader034.fdocuments.us/reader034/viewer/2022042209/5eac857b9c764034935bb6cc/html5/thumbnails/58.jpg)
54
the chute had to be redistributed so that the greater portion .of the
flow entered the stilling basin in the vicinity of the side walls. The
additional flow in these areas was necessary to destroy or minimQze the
eddies formed. It was found by the model tests that the desired distri
bution of flow could be accomplished only through the use of an arched
chute (elevation of centerline increased) or by use of large deflector
blocks placed near the toe of the chute and near each confining wall.
The observation tests also indicated that even though the arched chute
or deflector blocks were used, a more gradual transition from the chute
walls to the basin walls was necessary to improve flow conditions within
the basin.
73. Tests conducted on the types 17-27 and 36-37 designs were
concerned with the determination of the effect of basin elements on flow
conditions when vertical basin walls were used. These data were also
used as a basis for comparing the effect of sloped walls on stilling
basin performance. Tests indicated that the basin could be shortened if
baffle piers and an end sill were used. Comparison of basin performance
with sloping and vertical side walls indicated the ~uperiority of the
latter insofar as flow conditions within the basin proper are concerned.
·Both types were about equally effective in protecting the bed of the
exit channel from erosion, but velocities along the riprapped sides of
the exit channel were higher with the trapezoidal basin than with the
rectangular type. 'The slope of the chute walls had little effect on
basin performance when the basin walls were vertical.
74. Analysis of all test results obtained during the course of
the model study indicates that the best spillway and basin design, other
![Page 59: MODEL STUDY OF SPILLWAY ENID DAM, YOCONA RIVER … · The model study of the spillway for Enid Dam, proposed for con struction on the Yocona River in Mississippi, was concerned with](https://reader034.fdocuments.us/reader034/viewer/2022042209/5eac857b9c764034935bb6cc/html5/thumbnails/59.jpg)
55
than the vertical-wall design, incorporated a chute arched 5.1 ft at the
centerline, a 200-ft wide and 100-ft long apron, two rows of 8-ft baffle
piers, and a 5-ft end sill (type 32 design). Scour and velocity data '
recorded on this design indicate it to be safe. The eddies existing at
the toe of the chute were still present, although reduced in size.
![Page 60: MODEL STUDY OF SPILLWAY ENID DAM, YOCONA RIVER … · The model study of the spillway for Enid Dam, proposed for con struction on the Yocona River in Mississippi, was concerned with](https://reader034.fdocuments.us/reader034/viewer/2022042209/5eac857b9c764034935bb6cc/html5/thumbnails/60.jpg)
56
PART V: SUMMARY OF TEST RESULTS
75. The model study of the spillway for Enid Dam served its
purpose in providing the desired information regarding capacity, hydrau
lic performance, and the effect of sloping. side walls on spillway and
stilling-basin action. Tests indicated the need for alterations to
the approach walls at the spillway crest, and permitted the development
of two alternate stilling-basin designs with sloping side walls which
gave satisfactory performance. Tests also were conducted on stilling
basins with vertical side walls to provide data for comparison of the
relative effectiveness of rectangular- and trapezoidal-shaped basins.
76. Model tests to study the capacity of the spillway-crest width
as originally designed indicated that at a pool elevation of 283.4 a dis
charge of 63,000 cfs could be passed. The computed capacity at a pool
elevation of 284 was 49,700 cfs. The additional capacity resulted from
the increased cross-sectional area provided at the crest by the sloping
side walls. Tests also indicated the desirability of extending the slope
of the chute walls upstream to intersect the approach walls at or up
stream from the crest. This revision (types A or B approach walls),
although reducing the crest width, eliminated the standing waves adjacent
to each chute wall noted in tests of the walls as originally designed.
The reduction in crest width was only about 7 ft and a discharge of 57,000
cfs, which was in excess of the desired capacity, could be passed at a
pool elevation of 284.
77. The model study provided valuable information in connection
with the design of trapezoidal-shaped stilling basins. The tests
![Page 61: MODEL STUDY OF SPILLWAY ENID DAM, YOCONA RIVER … · The model study of the spillway for Enid Dam, proposed for con struction on the Yocona River in Mississippi, was concerned with](https://reader034.fdocuments.us/reader034/viewer/2022042209/5eac857b9c764034935bb6cc/html5/thumbnails/61.jpg)
57
demonstrated the performance of alternate basin designs which, when
reviewed from the standpoint of efficiency and economy, formed the basis
for selection of a standard rectangular-shaped stilling basin as the
final design. In all, 37 alternate stilling-basin designs were investi
gated.
78. Initial model tests indicated that successful design for a
trapezoidal-shaped stilling basin is contingent upon the proper passage
of flow from the chute into the stilling basin. The reentrant angles on
either side of the stilling basin caused by the intersection of the
chute and basin walls prevented the even distribution of flow across the
basin; large eddies were formed adjacent to each wall, confining the
chute flow to a limited fraction of the total basin width. Attempts to
eliminate these eddies and force the formation of the jump by addition
of baffle piers, reduction in basin width, and divergence or convergence
of chute walls, were unsuccessful. Additional tests indicated that
either an arching of the floor of the chute by increasing the elevation
along the centerline (type 32 design), or the use of large blocks on
the chute near its junction with the basin (type 34 design), were the
only plans which would improve basin action. The arching of the chute
(type 32 design) forced the areas adjacent to the walls to. carry a
greater proportion of the discharge, thereby reducing the size of the
eddies adjacent to the basin walls. Arching of the chute was started
about 12 ft downstream from the spillway crest in order not to reduce
the spillway capacity. The large deflector blocks of the type 34 de
sign, placed on the chute about 47.5 ft above the toe of the chute and
about 20ft from the side walls (plate 32), were so shaped as to change
![Page 62: MODEL STUDY OF SPILLWAY ENID DAM, YOCONA RIVER … · The model study of the spillway for Enid Dam, proposed for con struction on the Yocona River in Mississippi, was concerned with](https://reader034.fdocuments.us/reader034/viewer/2022042209/5eac857b9c764034935bb6cc/html5/thumbnails/62.jpg)
58
the direction of flow near the chute side walls and to cause it to
follow the basin walls. In each of these two designs, side transition
walls from the chute to the basin, two rows of baffle piers, and an end
sill were also found necessary.
79. Tests conducted with vertical basin walls clearly indicated
the superiority of vertical walls in providing good flow conditions
within the basin proper. However, as mentioned previously in this
report, the types 32 and 34 designs were about equally effective in pro
tecting the bed of the exit channel from erosion. Attention is invited
to the fact that bottom velocities over the riprapped side slopes of the
exit channel were higher with a,trapezoidal-shaped basin, since the side
slopes of the exit channel were a continuation of the basin walls. On
the other hand the use of vertical-type walls formed a slack-water area
over the riprapped side slopes immediately below the basin.
![Page 63: MODEL STUDY OF SPILLWAY ENID DAM, YOCONA RIVER … · The model study of the spillway for Enid Dam, proposed for con struction on the Yocona River in Mississippi, was concerned with](https://reader034.fdocuments.us/reader034/viewer/2022042209/5eac857b9c764034935bb6cc/html5/thumbnails/63.jpg)
TABLES
![Page 64: MODEL STUDY OF SPILLWAY ENID DAM, YOCONA RIVER … · The model study of the spillway for Enid Dam, proposed for con struction on the Yocona River in Mississippi, was concerned with](https://reader034.fdocuments.us/reader034/viewer/2022042209/5eac857b9c764034935bb6cc/html5/thumbnails/64.jpg)
FRESSURES OVER SPIU..WAY CREST AND CHUTE
ORIGINAL DESIGN
Discharge • 20,000 cfs Discharge e 40,000 cfs Pool Elev. = 275.7 Pool Elev. = 279.81 Tailwater Elev. • 215.0 Tailwater Elev. 218,6
Piezometer Elevation of Number Piezometer Piezometer Piezometer
Reading Pressures Reading Pressures
1 260.0 276.0 16.0 200.0 20.0
2 263.0 275.5 12.5 279.5 16.5
3 267.0 273.5 6.5 275.5 8.5
4 268.0 271.5 3.5 271.5 3.5
5 267.9 271.5 3.5 272.0 4.0
6 267.3 270.5 3.0 272.0 4.5
7 260.0 262,0 2.0 265.0 5.0
8 250.0 251.0 1,0 253.0 3.0
9 2.35.0 236.0 1.0 237.0 2,0
10 228.0 226.5 - 1.5 227.5 - 0.5
11 210.0 210.0 o.o 210.0 o.o
12 205.0 205.0 o.o 205.0 o.o
13 200.0 209.0 '9.0 208.5 8.5
1
NarE: Piezometer readings are recorded in ft msl, Pressures are recorded in prototype ft of water to the nearest 0.5 ft. Location of piezometers are shown on plate.T.
Discharge • 63,000 cfs Pool Elev. c 283.4 Tailwater Elev. • 222.7
Piezometer Reading Pressures
283.5 2~3.5
282.5 19.5
276.5 9.5
270.5 2.5
272.5 4.5
273.0 5.5
267.0 7.0
255.0 5.0
239.0 4.0
229.0 1.0
212.0 2.0 ' '
205.5 0.5
203.0 3.0 .
![Page 65: MODEL STUDY OF SPILLWAY ENID DAM, YOCONA RIVER … · The model study of the spillway for Enid Dam, proposed for con struction on the Yocona River in Mississippi, was concerned with](https://reader034.fdocuments.us/reader034/viewer/2022042209/5eac857b9c764034935bb6cc/html5/thumbnails/65.jpg)
STILLIN'Q-Bli.SU4 DESIGN.3 INV~ST!GATED
U.ngth Width Location Height Lo~ation of Baffles Height of Baffles Slope Be.oin Type of of of of Row Row Row Roo of Reference Remarks Design. Chute Apron (rt) Basin (rt) &nd Sill (rt) &nd Sill (rt No. 1 (rt) llo. 2 (rt) No. 1 (rt) No. 2 (ft) Basin Walls
Originol Flat 360 200 --- --- --- --- --- --- 1 ml 2 Basin as originally deaigned.
1 Flat 360 200 --- --- --- --- --- --- 1 on 2 Ten-!'t de"ltat<;ts locat9d across toe of chute.
2 Flat 240 84 --- --- --- --- --- --- 1 on 2 Figure 8 'fransition from o.bute walls to basin walls.
3 Flat 150 84 145 5 30 1,5 5 10 1 on 2 Fie;ure 8 Transition from chute walls to basin walls.
Tan-ft Cantatas located acr.,ss toe of chute. 4 Flat 150 84 145 5 30 45 5 10 1 on 2 Figure 8 Transition from ::hute walls to basin walls.
Ten-ft solid step located across toe of chute. 5 Flat 150 84 145 5 30 45 5 10 1 on 2 Figure 8 Transition from chilte walls to basin walls.
6 Flat 240 144 --- --- --- --- --- --- 1 on 2 Figure 11 Ten-ft solid step located across toe of chute. Transition from chute walls to basin walls.
7 Flat 150 144 145 5 30 45 5 10 1 on 2 Figure 11 Ten-ft solid step located across toe of chute. Transition from chute walls to basin walJ.s.
Ten .. !'t dentates located across toe of chute. 8 Flat 150 w. 145 5 30 45 5 10 1 on 2 Figure 11 Transition from chute walls to basin walls.
Ten-ft dento.tes removed from toe of chute. 9 Flat 150 144 145 5 )0 45 5 10 1 on 2 Figure 11 Tro.:1sitinn from chute walls to basin walls.,
10 Flat 240 144 --- --- --- --- --- --- 1 on 2 Figure 11 Transition from chute walls to basin walls.
ll Flat 150 144 11.5 5 36 64 8 12 Fbe-ft solid step located across toe o! chute.
1 on 2 . Figure n Transition from chu't$ walls to basin walls •
1 on 4 chute slope from top of conduit ending in a solid
12 Flat 150 200 145 5 36 64 8 12 1 on 2 step 10 ft high. Channel excavated on each side to deflect flow. Gn.ute arched transversely" 6.7 ft higher in center,
13 Arched 150 200 145 5 36 64 8 12 1 on 2 E::r:~u~ ~~i~!:~. elevation at sides. TrMsition
ChUte arched transvet"sely' .3.3 ft higher in center,
14 145 taperad to original elevation at sides. Transition
Arched 150 200 5 36 64 8 12 1 on 2 from chute to basin Chute arched transversely 3.3 tt high9r in center, tapered to origi."lal elevation at sides. Five ft solid
15 Arched 150 200 11.5 5 36 61, 8 12 1 on 2 step, deflectors at toe· of chute.
16 Flat 150 200 145 5 36 64 A 12 OriJ$inal design chute with 10-ft deflectors near each
1 on 2 chute wall at entrance to basin.
17 Flat 150 200 145 5 36 64 A 12 Vertical Transition from chute walls to basin walls.
18 Flat 150 200 145 5 --- --- --- --- Vertical Transition from chute walls to basin walls.
19 Flat 150 200 145 5 60 88 8 12 Vertical Tr.~'nsition frOm chute walls to basin walls.
![Page 66: MODEL STUDY OF SPILLWAY ENID DAM, YOCONA RIVER … · The model study of the spillway for Enid Dam, proposed for con struction on the Yocona River in Mississippi, was concerned with](https://reader034.fdocuments.us/reader034/viewer/2022042209/5eac857b9c764034935bb6cc/html5/thumbnails/66.jpg)
TABLE 2 (Continued)
STILLING-BASIN DESIGNS INVESTIGATED
langth Width Location Height Location of Battles Height of Batnes Slopa Basin Typo or of or or Row Row Row Row of Reference Remarks Dooigu Chuto Apron (rt) Basin (ft) End Sill (ft End Sill (ft No. 1 (rt) No. 2 (rt) No. 1 (rt) No. 2 (rt) Basin Walls
20 Flot 150 200 145 5 45 --- 12 --- Vertical Transition from chute walls to basin walls.
21 Flat 150 200 145 5 75 103 8 12 Vertical Transition from chute walls to basin walla.
22 Flot 150 200 145 5 45 73 8 12 Vertical Transition from chute walls to basin walls.
23 Flot 150 200 145 5 75 93 8 12 Vertical Transition f'rom ohute walls to basin walls.
24 Flot 150 200 145 5 25 44 6 6 Vertical Transition from. chute walls to basin n.lls.
25 Flot 150 200 145 5 75 93 6 6 Vertical Tr:m.sition from chute walla to basi.Q walls.
. 26 Flot 150 200 --- --- --- --- --- --- Vertieal Transition from chute walls to basin walls.
27 Flot 150 200 145 5 25 44 6 6 Vertical Vertical we.l.ls extended from crest to end of apron. Chute arched transversely 3 .,3 f't higher in center 1 tapered to original elevation at sides. Transition
28 Arched 265 160 260 5 70 90 6 6 1 on 2 Figure 17 from chute walls to basin walls. Chute arched transversely 5.12 £t higher in center,
11..5 ~pared to original elevation at sides. 'l'ransition
29 Arched 150 200 5 --- --- --- --- 1 on 2 Chute arched transversely 5.12 ft higher in center,
~~~~.~ ~::~r!~ ~::~!t!~~,~t sides. Transition
30 Arched 100 200 95 5 --- --- --- --- 1 on 2 Chute arched transversely 5 • .12 f't higher in center,
31 Arohed 100 200 95 5 35 ;~pared to o:~~:mal elevation at sides. Transition --- 8 --- 1 on 2 Chute arched transversely 5.12 f't higher in center,
Fioure 18 ;~~~ .. ~ ~::~~!~! ~:~~t!~~1 :t sides. Transition
32 Arched 100 200 95 5 35 56 8 8 1 on 2
33 Arched 100 200 95 5 35 56 6 6 1 on 2
Chute arched transversely' 5.12 f't higher in center, ;!:~e .. z.o ~:~~~ !~~tion at aides. Transition
Two 15-tt deflectors located on chute near each side-'"- Flat 100 200 Q< 5 35 56 8 8 1 on 2 Figure 19 wall. Transition from chute walls to basin walls
Same as type .34 design with def~ctor removed. 35 Flat 100 200 95 5 35 56 8 8 1 on 2 Fioure 21 Transition from chute walls to basin walls.
36 Flat 100 200 95 5 35 56 8 8 Vertical Transition from chute walls to basin walls.
Transition from chute walls to basin walls. Training 37 Flat 100 200 95 5 35 56 8 8 Vertical walls extended and rounded on 100-f't radius.
38 Flat 100 200 95 5 35 56 8 8 1 on 2 !!~~~:!s~!~~nded up the l~on-2 slopes of the
NOTE: In all stilling ... basin designs except the original, type 1, and type 27 warped transitions from the chute walls to the basin walls are used.
![Page 67: MODEL STUDY OF SPILLWAY ENID DAM, YOCONA RIVER … · The model study of the spillway for Enid Dam, proposed for con struction on the Yocona River in Mississippi, was concerned with](https://reader034.fdocuments.us/reader034/viewer/2022042209/5eac857b9c764034935bb6cc/html5/thumbnails/67.jpg)
PLATES
![Page 68: MODEL STUDY OF SPILLWAY ENID DAM, YOCONA RIVER … · The model study of the spillway for Enid Dam, proposed for con struction on the Yocona River in Mississippi, was concerned with](https://reader034.fdocuments.us/reader034/viewer/2022042209/5eac857b9c764034935bb6cc/html5/thumbnails/68.jpg)
CENTER LJ'fNE"-r"'t--.,.--,--
130.
HALF PLAN
-ELEV 243.0
PROFILE
"' ~== -ZID
-z1s ... ... ELEV 230
0 0 !!
MODEL STUDY OF SPILLWAY ENID DAM, YOCONA RIVER, MISSISSIPPI
SPILLWAY PLAN AND PROFILE ORIGINAL DESIGN
![Page 69: MODEL STUDY OF SPILLWAY ENID DAM, YOCONA RIVER … · The model study of the spillway for Enid Dam, proposed for con struction on the Yocona River in Mississippi, was concerned with](https://reader034.fdocuments.us/reader034/viewer/2022042209/5eac857b9c764034935bb6cc/html5/thumbnails/69.jpg)
"'0 r ~ rn 1\)
WARP FROM ION.J TO !ON2
WARP FROM /ONJ TO!ON2
SLOPE ION:J
t I ON 2.68
1.30 521
138.081
ORIGINAL
SLOPE !ON3
t ION 2.68
WARP FROM JON.J TO!ON2
SLOPE I ON 18 SLOPE I ON 3
~.:;-;-~-~~'i-~~~~~i'§Jft!!~ii:"":~~~~~:~~~~: _{:-,:~~~~~~:;:~~=~~~~~~~:;~g I
NOTE: SEE RATING CURVES ON PLATE 6 DETAILS OF APPROACH CHANNELS ARE ALSO SHOWN ON PHOTOGRAPHS 3,6 AND 9
_FLOW ! .:;CREST OF WEIR ......... ELEV 258
I
t/ON2.68
TYPE B
MODEL STUDY OF SPILLWAY ENID DAM, YOCONA RIVER, MISSISSIPPI
DETAILS OF APPROACH CHANNELS
![Page 70: MODEL STUDY OF SPILLWAY ENID DAM, YOCONA RIVER … · The model study of the spillway for Enid Dam, proposed for con struction on the Yocona River in Mississippi, was concerned with](https://reader034.fdocuments.us/reader034/viewer/2022042209/5eac857b9c764034935bb6cc/html5/thumbnails/70.jpg)
~
~
&__
!?._
~
~
5.0 l.£_
~
~
12._
l.£_
12..._
g_ li._
"'0 r ~ (TI
w
!:2..._ g_
~ ~
~ ~
~ !.Q._
~ ~
12...- ~
ORIGINAL OISCHARGE=63,000 CFS
60 0 M_ ~ ~ .P.2.- ru_ ~ ~ ~80
I ~ ~ ~ ru2.._ u___ ~ ~ li_ lza.o §.E_,_ (!!:3._ ~
JO
TYPE A DISCHARGE= 50,000 CFS
~
~
~
~
~
~
~ fti-
~ ~ ~ !.£.__ ~ 121.5
I 1.i_ g_ kll_
g__ g_ I fll-
u.,._ M._ ~
li- ~ IJ'OO r=-295
TYPE B
DfSCHARGE=SO,OOO CFS
NOTE' VELOCITIES ARE IN FEET PER SECOND IN PROTOTYPE
MODEL STUDY OF SPILLWAY ENID DAM, YOCONA RIVER, MISSISSIPPI
BOTTOM VELOCITIES ORIGINAL AND TYPES A AND 8
APPROACH CHANNELS SCALES
![Page 71: MODEL STUDY OF SPILLWAY ENID DAM, YOCONA RIVER … · The model study of the spillway for Enid Dam, proposed for con struction on the Yocona River in Mississippi, was concerned with](https://reader034.fdocuments.us/reader034/viewer/2022042209/5eac857b9c764034935bb6cc/html5/thumbnails/71.jpg)
0')
"' ,...: <0
+ "' "' <( rVl
.. .; ~. ..
ELEV 258
0 0 + 0 2
~ Cl)
... c;; Ill c:i + 0 2
~ Cl)
1-'
•. :.'.:::~·-{~::;/;~:::·:·:;~ ~.~?:~.~? ;<:t~::~;?~t:P.:::~:·::t :·: ..... :. ·.· . ELEV 266.54 .. :.•.<t•: .. • .._.. <1 • • . /1. V; ·<i · ·V • · .V ·, ·. •'<1· · · • ··: .. _. .• ,,_.,
rVl w a: u
..
MODEL STUDY OF SPILLWAY ENID DAM, YOCONA RIVER, MISSISSIPPI
DETAILS OF CREST SECTION ORIGINAL DESIGN
sto ===--llli':o ======::'s'io ____ I20 FT.
![Page 72: MODEL STUDY OF SPILLWAY ENID DAM, YOCONA RIVER … · The model study of the spillway for Enid Dam, proposed for con struction on the Yocona River in Mississippi, was concerned with](https://reader034.fdocuments.us/reader034/viewer/2022042209/5eac857b9c764034935bb6cc/html5/thumbnails/72.jpg)
288
284
282
280
..J 278 ..
];
... .. .. 278 ...
~
z 0
~ 274
..
..J ..
..J 272 0 0 ..
270
288
288
284
_ ............... ~
~ ~ -- v.
--~ ~ ~ -- ~ /
_..¥"
~ ~--~ / / ~<
? ~ ~,_
/ I
~ LLWAY CREST £LEV 268.0
0 10
NOTE· VARIATION IN CREST LENGTH ORIGINAL DESIGN 237 FT TYPE A -200 FT TYPE B-200 FT TYPE C- 160 FT (CURVED)
15
TYPE C v:--~~
l------: ~ .,.......~ ~---..-
20
COMPULD MoiXLUM POt ELEV L4.0 (16t FT HEL) ~~
-~~ - ~
--~ ~-~ - r;:;;: ~-~ g~;;~~~~ r ~--
~-
~ ~ -.:.:_.::::::::::
·_::-~~
~ .---
---- - -v ~---~ ~ ~ ORIGINAL DESIGN MODEL
~-----
25 30 35
DISCHARGE IN 1,000 CFS
~~~
l-------1----- ~ ...,.,.~
~---""""' ---- ~~ .... --- --~
:-1-c=-~ - ,__
~_:..::::::: ~--~_..:
7 r- __} TYPE 8
f-:1 ..
40 45 50
MODEL STUDY OF SPILLWAY ENID DAM, YOCONA RIVER, MISSISSIPPI
SPILLWAY RATING CURVES ORIGINAL AND TYPES A, B, AND C
APPROACH CHANNELS
![Page 73: MODEL STUDY OF SPILLWAY ENID DAM, YOCONA RIVER … · The model study of the spillway for Enid Dam, proposed for con struction on the Yocona River in Mississippi, was concerned with](https://reader034.fdocuments.us/reader034/viewer/2022042209/5eac857b9c764034935bb6cc/html5/thumbnails/73.jpg)
_J
(/)
~
1-ILl ILl LL
~
z 0 j: ~ ILl _J ILl
300 r-------r-------~------~------.-------,-------.--------r-------.-------r------~--~--~------~---, 300
1-- WALL £ EV 285. 0-~ -
280 280
1-- -_J
(/)
260 260 ~
1-1-- - ILl
ILl LL
240 240 z -WALL t LEV 230.0 ---..... z
Q I-1-
~ 220 ILl
_J 220 ILl
I- -
200
r:.. ~
180 1-~------~------~------~------~------...l-------...l-------~------~------~------~------~------~---...ll80 99+40 +80 100+20 +60 101+00 +40 +80 102+20
STATIONS SECTION ALONG l. OF SPILLWAY
TEST DATA
DISCHARGE 63,000 CFS
+60 103+00 +40 +80
MODEL STUDY OF SPILLWAY
ENID DAM, YOCONA RIVER, MISSISSIPPI
WATER-SURFACE PROFILE ORIGINAL DESIGN
![Page 74: MODEL STUDY OF SPILLWAY ENID DAM, YOCONA RIVER … · The model study of the spillway for Enid Dam, proposed for con struction on the Yocona River in Mississippi, was concerned with](https://reader034.fdocuments.us/reader034/viewer/2022042209/5eac857b9c764034935bb6cc/html5/thumbnails/74.jpg)
ELEV 268.0
ELEV 258.0
ORIGINAL DESIGN APRON ELEV 190.0
PIEZ PIEZ PIEZ
NO. (~~ ELEV (FT M S L)
P-1 99+89.92 260.0
P-2 99+92.92 263.0
P-3 99+97.03 267.0
P-4 100+00.00 268.0
P-5 100+01. 86 267.9
P- 6 100+ 04.93 267.3
P-7 100+26.89 260.0
P-8 100+56.89 250.0
P-9 101 +01.89 235.0
P-10 101 + 22.89 228.0
P-11 101+76.89 210.0
P-12 101+91.89 205.0
P-13 102+06.89 200.0
.1--~--F- 10
cONDuITS .::::::=.7" - -
ELEV 190
MODEL STUDY ENID DAM, YOCONA
PIEZOMETER
OF SPIL!-WAY RIVER, MISSISSIPPI
LOCATIONS
SCALE
OCI ~---.. c=~-----4i0====~ .... 80FT
![Page 75: MODEL STUDY OF SPILLWAY ENID DAM, YOCONA RIVER … · The model study of the spillway for Enid Dam, proposed for con struction on the Yocona River in Mississippi, was concerned with](https://reader034.fdocuments.us/reader034/viewer/2022042209/5eac857b9c764034935bb6cc/html5/thumbnails/75.jpg)
260
250
...J 240
"' ~ t-.., ..,
230 "-
~
z 0 ;::
220 ~ .., ...J ..,
210
200
190
!='
1::-
COMPUT£0 MAXIMUM TAIL~ ~ t-I- __ v--
v f-"'"
1::-
/ COMPUT£0
~ 1/ ---f---I/
~
f-
1::-t-
0 4 8 12
NOTES: MAXIMUM TAILWATER WAS COMPUTED ASSUMING NO SCOUR MINIMUM TAILWATER ,WAS COMPUTED ASSUMING MAXIMUM SCOUR
16
MINIMUM TAILWAT£R--;;
.t----- f--r COM~UT£0 02 '__} WITH STILLING BASIN AT £L£V 190.0
20 24 28
DISCHARGE IN 1000 C F S
-
------ --.... -
32 36 40 44 48 5 2 56
MODEL STUDY OF SPILLWAY ENID DAM, YOCONA RIVER, MISSISSIPPI
TAILWATER RATING CURVES
![Page 76: MODEL STUDY OF SPILLWAY ENID DAM, YOCONA RIVER … · The model study of the spillway for Enid Dam, proposed for con struction on the Yocona River in Mississippi, was concerned with](https://reader034.fdocuments.us/reader034/viewer/2022042209/5eac857b9c764034935bb6cc/html5/thumbnails/76.jpg)
"l _J
~
~
t 210
= ~ LEfT BANK
190
160 120
"'l "' ::> 1-... 210
= >
LEFT B.A .. NK w ..J
"' 190
BO
TYPE II DESIGN STATION 103 +86.89 (END SILL)
DISCHARGE= 53,800 C F 5
40
DISTANCE IN FEET
TYPE 14 DESIGN STATION 103+86.89 (END SILL)
DISCHARGE::: 53,800 CF S
40
DISTANCE IN FEET
TYPE" 25 DESIGN STATION 103+66.69 (END SILL)
DISCHARGE =53,800 CFS
DISTANCE IN FEET
r _J
"' ~ t 210
= >
RIGHT BANK w _J
100 w
_J
"' "' ~ ~
t ::: = = ~ ~
d
r ..J
"' ::IE
1-210 ...
~
RIGHT BANK > "' ..J
IQO "'
"mt ~
~ 210
= > w
LEFT BANK _J w 100
"l 210
LEFT BANK
190
TYPE 28 DESIGN STATION !05+01.89 (END SILY
DISCHARGE= 40,600 Cf' S
DISTANCE IN FEET
TYPE 29 DESIGN STATION 103+86.89 ~NO SILL;)
DISCHARGE= SO,OOO C F S
DISTANCE IN FEET
NOTE: VELOCITIES ARE IN PROTOTYPE FT PER SEC
r _J
"' ~ 210 t
= ~ RIGI·oiT BANK
190
r _J
~
'" 210 ~
= ~ RIGHT BANK
190
• MODEL STUDY OF SPILLWAY ENID DAM, YOCONA RIVER, MISSISSIPPI
VELOCITY AT
DISTRIBUTION END SILL
![Page 77: MODEL STUDY OF SPILLWAY ENID DAM, YOCONA RIVER … · The model study of the spillway for Enid Dam, proposed for con struction on the Yocona River in Mississippi, was concerned with](https://reader034.fdocuments.us/reader034/viewer/2022042209/5eac857b9c764034935bb6cc/html5/thumbnails/77.jpg)
1J r ~ IT!
0
..J
'~[ ., :1
... ... 210 ; > .. ..J .. teo
~ 2::r ; > .. ..J a.J 190
TYPE 32 DESIGN STATION 103+3&.89 (END SILL)
DISCHARGE: .50,000 C F S
DISTANCE IN F'EET
TYPE 32 DESIGN STATION 103+36.89 (END SILL)
DISCHARGE = 25,000 C F S
DISTANCE IN FEET
NOTE: VELOCITIES ARE IN PROTOTYPE FT PER SEC
r ..J Cl)
:1
... 210 ...
~ > ... ..J
190 ...
r ..J
"' :1
t:: 210 ~
> "' ..J
190 ..
..J
~[ Cl)
:1
t:: 210 ~
> .. ..J
"' 1g0
..J
~l "' :1 ... ... 210 ~
> "' ..J
"' 190
TYPE 34 DESIGN STATION 103+36.89 ~NO SILL)
DISCHARGE= 50,000 C F 5
DISTANCE IN FEET
TYPE 30 DESIGN STATION 103+36.89 ~NO SILL)
DISCHARGE = 50,000 C F S
J :~ ~ ! > "' ..J
190 w
~ > l :~: ;
RIGHT BANK j 19,0 .....
DISTANCE IN FEET
MODEL STUDY OF SPILLWAY ENID DAM, YOCONA RIVER, MISSISSIPPI
VELOCITY DISTRIBUTION AT END SILL
![Page 78: MODEL STUDY OF SPILLWAY ENID DAM, YOCONA RIVER … · The model study of the spillway for Enid Dam, proposed for con struction on the Yocona River in Mississippi, was concerned with](https://reader034.fdocuments.us/reader034/viewer/2022042209/5eac857b9c764034935bb6cc/html5/thumbnails/78.jpg)
'1J r ~ [11
l( ~ ..J 0: ., ... 0
"' z :::; 0:
"' ,_ z "' u :;;; 0 0: ... ,_ "' "' ... !:
"' u z ~ ., 0
0
SECTION ALONG CENTERLINE OF STILLING ,BASIN
SCALE 20::..=-~---~~20~==~4:;:,0 __ ... 20F'EET
NOTE: ELEVATIONS ARE IN FEET REFERRED TO M S L
BED MOLDED FLAT TO BASIN ELEVATION AT START OF TEST
150
50
MODEL STUDY OF SPILLWAY ENID DAM, YOCONA RIVER, MISSISSIPPI
SCOUR PATTERN TYPE 24 DESIGN
DISCHARGE 53 1800 C F S TAILWATER ELEVATION 221.7
l( 3: ..J ..J a: <I)
"-0
"' z :::; a: "' 1-z w u :;;; 0 a: ... 1-w UJ "-
!': w u z ~ <})
0
![Page 79: MODEL STUDY OF SPILLWAY ENID DAM, YOCONA RIVER … · The model study of the spillway for Enid Dam, proposed for con struction on the Yocona River in Mississippi, was concerned with](https://reader034.fdocuments.us/reader034/viewer/2022042209/5eac857b9c764034935bb6cc/html5/thumbnails/79.jpg)
...J Cl)
~
1-IJJ IJJ lA..
~
z Q 1-~ IJJ ...J IJJ
300~-----.------~------~------~------~~------,-------.-------.-------.-------r------.-------,---, 300
280
260
240
220
200
180
- -WALL iE'LEV 285. 1-----...
280
- -...J Cl)
260 ~
f-r- - IJJ
IJJ lA..
240 ~
r- WALL E EV 230.0 1---... ·Z
Q 1-
~
r-
220 LIJ
~ ...J
~ w
-_ _____.,
r-
~------~-----...l--~--~------~------~------~------...l-------~------~------~-----...l~-----...l---...ll80 99+40 +80 100+20
TEST DATA
DISCHARGE 50,000 C F S TAILWATER ELEV 220.4
+60 101+00 +40 +80 102+20
STATIONS SECTION ALONG t. OF SPILLWAY
+60 103+00 +40 +80
MODEL STUDY OF SPILLWAY
ENID DAM, YOCONA RIVER, MISSISSIPPI
WATER-SURFACE PROFILE
TYPE 25 DESIGN
![Page 80: MODEL STUDY OF SPILLWAY ENID DAM, YOCONA RIVER … · The model study of the spillway for Enid Dam, proposed for con struction on the Yocona River in Mississippi, was concerned with](https://reader034.fdocuments.us/reader034/viewer/2022042209/5eac857b9c764034935bb6cc/html5/thumbnails/80.jpg)
'"U r )> -I rn
....1 <I)
::l!
1-UJ UJ L...
~
z 0 j: ~ UJ ....1 w
300r------,-------.-------.-------.------.-------.-------~------.-----~r------,-------.-------.--~ 300
280
260
240
220
200
180
f- -WALL E EV 285.0 r---.
280
f- -....1 <I)
.;t~ 260 ::l!
1-r- - UJ
UJ L...
240 ~
- WALL E EV 2.30.0 ------, z Q 1-
~ 220 UJ
....1 w
- ~ ,....-
-
-
~------'------~-------L-------L ______ _L ______ J_ ______ ~------L-------L-------L-----~------~--~180
99+40 +80 100+20 +60 101+00 +40 +80 102+20 +60 103+00 +40 +80
STATIONS SECTION ALONG ct. OF SPILLWAY
TEST DATA
. DISCHARGE 25,000 C F S TAILWATER ELEV 216.0 MODEL STUDY OF SPILLWAY
ENID DAM, YOCONA RIVER, MISSISSIPPI
WATER-SURFACE PROFILE
TYPE 25 DESIGN
![Page 81: MODEL STUDY OF SPILLWAY ENID DAM, YOCONA RIVER … · The model study of the spillway for Enid Dam, proposed for con struction on the Yocona River in Mississippi, was concerned with](https://reader034.fdocuments.us/reader034/viewer/2022042209/5eac857b9c764034935bb6cc/html5/thumbnails/81.jpg)
'"U r )> -1 fT1
~
~ ~ _J
ii: "' ... 0
"' z ::; 0:
"' ... z "' u
::li 0 0: ... ... "' "' ... !':
"' u z ~ "' ;;
150
50
ot----
50
150
"' ~ :;: :3
ELEV 196.0-
SECTION ALONG CENTERLINE OF STILLING BASIN
SCALE Z:ll,o-=:=--=:='l. ___ jiiZO'====·'\iiO ___ ,.,,OFEE"T
NOTE: ELEVATIONS ARE IN FEET REFERRED TO M S L
BED MOLDED FLAT TO BASIN ELEVATION AT START Or TEST
/.9o
192
200
150
MODEL STUDY OF SPILLWAY ENID DAM, YOCONA RIVER, MISSISSIPPI
SCOUR PATTERN TYPE 25 DESIGN
DISCHARGE 53,800 C F S TAILWATER ELEVATION 221.7
~ ~ _J
ii: "' ... 0
"' ~ _J 0:
"' ... z "' u
::li ~ ... ... "' "' ... ~ w u z ~ "' 0
![Page 82: MODEL STUDY OF SPILLWAY ENID DAM, YOCONA RIVER … · The model study of the spillway for Enid Dam, proposed for con struction on the Yocona River in Mississippi, was concerned with](https://reader034.fdocuments.us/reader034/viewer/2022042209/5eac857b9c764034935bb6cc/html5/thumbnails/82.jpg)
IJ r ~ m ()1
l( ~ -' a: "' ... 0
'" z ::; a: w 1-z '" u
~ 0 a: ... 1-
'" w ... ~
w u z ;£ "' 0
200 I I I
ISO
100
50
0
so
100
~ VERTICAL WALL--.
w m m m m m - m m m
1 m ------
m m g --------m-rr]~
m '" m m m m - m m m mm m
/ ISO
200 I I I I
I I I I I I I I I
~ _o __ o_. §,Q__ rr_ Z:L_ LL-~_Q____. ~ §,Q__ ZQ__ n___ .?2..._
1/.0 4.5---4f!._._.~-~ 4.5 5.0 6.0
~ :!,Q_ML.- li_ liL_ ilL_ ~ ~
~ ~~ liL_ M-- ~ M_ ~
~ §..,Q_~ li_ liL_ M.__ li_ M.._
~-~-~-~-~-~~~--------------------
p12-- :!,Q_li_._ ,J_,Q__. ~ ~ il..._ §,Q__
~ J..Q_,J_,Q__. ~ JJl.-_ liL_ ~ M2__
~ 'LQ_li_._ ~ liL_ liL.- ~ ~
11.5 4.5 4.5 3.5 3,0 3.0 ~ 5.0
_o __ o ____
~ M__. lQ___.__ _u___ u____.__ _o __ o ____
"-"',..__ M____ Z:.2__ n_____ li__.,__
I I I I I
I I
-
-------------------
I
200
I 50
l(
~ I -' 00 a:
<Jl
50
0
50
... 0 w z ::; a: '" 1-z '" u
1-w w ... ~
'" I 00 ~ ;£ <Jl
0
I so
200 101+00 101+50 102+00 102+50 103+00 103+50 104+00 104+50 105+00 105+50 106+00 106+50 107+00 107+50 108+00 108+50 109+00 109+50 110+00
SECTION ALONG CENTERLINE OF STILLING BASIN
SCALE
20.0 -==--==----2fi:0'====4·0---·60 FEEi
NOTE: ELEVATIONS ARE IN FEET REFERRED TO M S L
BED MOLDED FLAT TO BASIN ELEVATION
VELOCITIES ARE IN FEET PER SECOND IN PROTOTYPE
STATION
MODEL STUDY OF SPILLWAY ENID DAM, YOCONA RIVER, MISSISSIPPI
BOTTOM VELOCITIES TYPE 25 DESIGN
DISCHARGE 53,800 C F S TAILWATER ELEVATION 221.7
![Page 83: MODEL STUDY OF SPILLWAY ENID DAM, YOCONA RIVER … · The model study of the spillway for Enid Dam, proposed for con struction on the Yocona River in Mississippi, was concerned with](https://reader034.fdocuments.us/reader034/viewer/2022042209/5eac857b9c764034935bb6cc/html5/thumbnails/83.jpg)
'"U r )> -l rn
0>
?( 3 --' a: <11
"-0 w z J a: w 1-z w u
~ 0 a: "-
1-w w "-
~
w u z 10 <11 0
200 I I I I I I I I I
200
150 f- 150 Qg_ Q2.._ M.- ~ ~ ~
~ 100 VERTICAL
50 f-
!22.-- ~ 1.Jl.- ~ ~ 1A__
WALL-_ 15 5.0 4.5 1£.- 4.0 4.0 .J.O .J.O
w m m m ~ ~~ ~ ~ li2._ -lQ_ ~
m m m M__ _2,Q._ 1..d._ ~ 1.2.- M.._ ~ ~
OJ OJ ~ OJ ~ M._~ ~ ~ ~ !..2._ lid_
100
-50
0 ------ ----m m g
-m- ·----o ~~-~-~-~-~~~--------------- ---------0
501-
100
m OJ ~ ~ ~~ 1.J4_ ~ u_ ~ ~ mOJ
mm ~ M_~ ~ M_ M-- ,LQ_._ J.Q__
OJm ~ M_~ ~ li2- .ll.._ li4- M._ {]]OJ
mOJ 6.5 ~.u_ 4.5 4.0 4.0 4.0 ~
-50
100
M_ .. M__ ~ ~ liL_ ~ Q!L,_ QJ2_. li2_ il._ 12._ ~
150 f- 150
2~gi~+~O~O--~I~O~I~-,-0---10~2~~+-0~0~-I-0~2~+I~5~0---1~0~3L1+~0~0---I0-3~~-5~0--I0~~~+-0-0--1~0~4~+~5~0--1~05~~LO~O~--I0-5~+-5~0~-10~6~+~-0~0~-I-0~6~+~S-0--10-7-~~0-0--I0-7~+-5-0--I0-8~~+-0-0--I-0-8L+I_S_O __ I0-9~~~00---10-9~+-S-O---IIO_J+~go
"' "' "' "' "' "' "' "' "' '"
"' "' "'
SECTION ALONG CENTERLINE OF STILLING BASIN
SCALE
"'~o-==--=::'l.---~•o'====•'jo ___ olso FEET
NOTE: ELEVATIONS ARE IN FEET REFERRED TO M S L
BED MOLDED FLAT TO BASIN ELEVATION
VELOCITIES ARE IN FEET PER SECOND IN PROTOTYPE
STATION
ELEV 195.0
MODEL STUDY OF SPILLWAY ENID DAM, YOCONA RIVER, MISSISSIPPI
BOTTOM VELOCITIES TYPE 25 DESIGN
DISCHARGE 25,000 C F S TAILWATER ELEVATION 216.0
li 3 --' a: <11
"-0 w z J a: w 1-z w u
~ 0 a: "-1-w w "-
~ w u z 10 <11 i5
![Page 84: MODEL STUDY OF SPILLWAY ENID DAM, YOCONA RIVER … · The model study of the spillway for Enid Dam, proposed for con struction on the Yocona River in Mississippi, was concerned with](https://reader034.fdocuments.us/reader034/viewer/2022042209/5eac857b9c764034935bb6cc/html5/thumbnails/84.jpg)
lJ r ~ rn
~ ~ _j
0:
"' "-0 w z ::i a: w f-z w u
::; 0 a: "-
f-w w "-
": w u z "' f-
"' 0
200
ISO
50
0
200
ISO
210/~ \ "---214---
~~ VERTICAL WALL
STATION
SECTION ALONG CENTERLINE OF STILLING BASIN
SCALE -=-=='----===5---·60F"EE1' NOTE: ELEVATIONS ARE IN FEET REFERRED TO M S L
BED MOLo·Eo FLAT TO BASIN ELEVATION AT START OF TEST
100
204 __________ __
50
-----------------
50
100
150 ~ 206 212-----------
~ --------216-----
MODEL STUDY OF SPILLWAY ENID DAM, YOCONA RIVER, MISSISSIPPI
SCOUR PATTERN TYPE 26 DESIGN
DISCHARGE 53,800 C F S TAILWATER ELEVATION 221,7
~ 3 _j
,! Q_
<11
"-0
w z _j
a: w t-
3 u
::; 0 a: "-
f-w ~
": w u z ,::: <11 0
![Page 85: MODEL STUDY OF SPILLWAY ENID DAM, YOCONA RIVER … · The model study of the spillway for Enid Dam, proposed for con struction on the Yocona River in Mississippi, was concerned with](https://reader034.fdocuments.us/reader034/viewer/2022042209/5eac857b9c764034935bb6cc/html5/thumbnails/85.jpg)
'"0 r ~ rn
ELEV 245
WARP FROM ION.J TO!ON2
ELEV 251.0
ELEV ELEV 256.0
18
SLOP£ I ON .J
[[] [[J
[[] [[J []
[[] [[J
[[] [[J
[[] []] ------- --- t---- --ill---QJ-----,-------------l:ffii
[[J []
[[J []]
[[] []]
[[] []]
[[J []]
265'
PROFILE
ELEV 230
ELEV 190.0
MODEL STUDY OF SPILLWAY ENID DAM, YOCONA RIVER, MISSISSIPPI
SPILLWAY PLAN AND PROFILE TYPE 28 DESIGN
![Page 86: MODEL STUDY OF SPILLWAY ENID DAM, YOCONA RIVER … · The model study of the spillway for Enid Dam, proposed for con struction on the Yocona River in Mississippi, was concerned with](https://reader034.fdocuments.us/reader034/viewer/2022042209/5eac857b9c764034935bb6cc/html5/thumbnails/86.jpg)
'"U r ~ rn
li ~ ..J i[ Cl)
... 0
"' z 50 :::; "' "' .... z "' \)
;l; 0
"' ...
150
STATION
SECTION ALONG CENTERLINE OF STILLING BASIN
SCALE ziOo..:=:.or= ___ lllllii''===-=::'i·IOO ---60F'EE'T
NOTE: ELEVATIONS ARE IN F"EET REF" ERRED TO M S L
BED MOLDED FLAT TO BASIN ELEVATION AT START OF TEST
\~~218~
~ 214~ <"/o
208--
50
100
150
MODEL STUDY OF SPILLWAY ENID DAM, YOCONA RIVER, MISSISSIPPI
SCOUR PATTERN TYPE 29 DESIGN
DISCHARGE 50,000 C F S TAILWATER ELEVATION 220.4
li ~ ..J i[
"' ... 0
"' ;;!' ..J
"' "' .... z "' \)
;l;
~ ... .... "' "' ... ~
"' \) z to "' Ci
![Page 87: MODEL STUDY OF SPILLWAY ENID DAM, YOCONA RIVER … · The model study of the spillway for Enid Dam, proposed for con struction on the Yocona River in Mississippi, was concerned with](https://reader034.fdocuments.us/reader034/viewer/2022042209/5eac857b9c764034935bb6cc/html5/thumbnails/87.jpg)
."U r ~ (Tl
N 0
li ~ -' 0:
"' ... 0
"' z :::; a:
"' f-z "' v ::l; 0 a: ... f-
"' "' ... '!:
"' v z ~ "' 0
150.01
SECTION ALONG CENTERLINE OF STILLING BASIN
SCALE
20'i-=-~---:f20'====::'\4ij,O ---SO FEET
NOTE: ELEVATIONS ARE IN 'EET RE,ERRED TO M S L
BED MOLDED FLAT TO BASIN ELEVATION AT START Of TEST
STATION
"' 0>
ELEV 195.0
"' .,;
"' + "' Q
50
100
MODEL STUDY OF SPILLWAY ENID DAM, YOCONA RIVER, MISSISSIPPI
SCOUR PATTERN TYPE 29 DESIGN
DISCHARGE 25,000 C F S TAILWATER ELEVATION 216.0
li ~ -' 0: "' ... 0
"' ~ -' 0:
"' f-z "' v ::l; 0 0: ... f-
"' "' ... '!:
"' v z ~ "' Ci
![Page 88: MODEL STUDY OF SPILLWAY ENID DAM, YOCONA RIVER … · The model study of the spillway for Enid Dam, proposed for con struction on the Yocona River in Mississippi, was concerned with](https://reader034.fdocuments.us/reader034/viewer/2022042209/5eac857b9c764034935bb6cc/html5/thumbnails/88.jpg)
1J r ~ (Tl
f\)
l( ~ ..J 0: U)
... 0
"' z :::; a: "' 1-z "' u
~ 0 a: ... 1-
"' "' ... ~
"' u z ~ Ill 0
SECTION ALONG CENTERLINE OF STILLING BASIN
SCALE
20~=-=="'---lf'"''===~·li,O __ _.SO FEET
NOTE: ELEVATIONS ARE IN F"EET REFERRED TO M S, L
BED MOLDED FLAT TO BASIN ELEVATION AT START OF TEST
STATION
200
150
100
50
0
50
MODEL STUDY OF SPILLWAY ENID DAM, YOCONA RIVER, MISSISSIPPI
SCOUR PATTERN TYPE 30 DESIGN
DISCHARGE 50,000 C F S TAILWATER ELEVATION 220.4
l(
~ ..J 0: "' ... 0
"' z :::; a: "' 1-z "' u
~
it ... 1-
"' "' ... ~
"' u z ~ Ill i5
![Page 89: MODEL STUDY OF SPILLWAY ENID DAM, YOCONA RIVER … · The model study of the spillway for Enid Dam, proposed for con struction on the Yocona River in Mississippi, was concerned with](https://reader034.fdocuments.us/reader034/viewer/2022042209/5eac857b9c764034935bb6cc/html5/thumbnails/89.jpg)
150
150
~~~~~--~~~~~~~~~--~~~~~~~~~~~~~~~~~~~~~~~--~~~~~~--~~----~----~------~----_J200 IOI+SO 102+00 102+50 103+00 105+50 106+00 106+50 107+00 107+50 108+00 108+50 109+00 109+50 110+00
SECTION ALONG CENTERLINE OF STILLING BASIN
SCALE
20li.=..:='io,_ __ ~20'===::'lli.---80 FEET
NOTE: ELEVATIONS ARE IN FEET REFERRED TO M S l
BED MOLDED FLAT TO BASIN ELEVATION AT START Of TEST
STATION
MODEL STUDY OF SPILLWAY ENID DAM, YOCONA RIVER, MISSISSIPPI
SCOUR PATTERN TYPE 30 DESIGN
DISCHARGE 25,000 C F S TAILWATER ELEVATION 216.0
... 0 w z :::i a: w 1-z w u
1-w w ... ~
w u z
~ 0
![Page 90: MODEL STUDY OF SPILLWAY ENID DAM, YOCONA RIVER … · The model study of the spillway for Enid Dam, proposed for con struction on the Yocona River in Mississippi, was concerned with](https://reader034.fdocuments.us/reader034/viewer/2022042209/5eac857b9c764034935bb6cc/html5/thumbnails/90.jpg)
"U r ~ [11
!\) 0J
200
?;: ~ ...J a: <f)
"-0 w z J a: w ~ z w v
0 ::; 0 a: "-
~ w w "-
~
w v z < ~ <f)
0
[]
[]
--[[]--
[]
[]
[[]
[[]
SECTION ALONG CENTERLINE OF STILLING BASIN
SCALE ""'ll.=-=='lo---ift""?:=:==::'\il,--_,l6'0 FEE"T
NOTE: ELEVATIONS ARE IN F'EET REFERRED TO M S L
BED MOLDED FLAT TO BASIN ELEVATION AT START OF TEST
STATION
200
ISO
---
50
MODEL STUDY OF SPILLWAY ENID DAM, YOCONA RIVER, MISSISSIPPI
SCOUR PATTERN TYPE 31 DESIGN
DISCHARGE 50,000 C F S TAILWATER ELEVATION 220.4
?;: ~ ...J a: <f)
"-0 w z J a: w ~ z w v ::; 0 a: "-~ w w "-
~ w v z ;! <f)
0
![Page 91: MODEL STUDY OF SPILLWAY ENID DAM, YOCONA RIVER … · The model study of the spillway for Enid Dam, proposed for con struction on the Yocona River in Mississippi, was concerned with](https://reader034.fdocuments.us/reader034/viewer/2022042209/5eac857b9c764034935bb6cc/html5/thumbnails/91.jpg)
CENTER LINE---"'----
0 0 + 0 0
156.42 1
HALF PLAN
PROFILE
SCALE
80.481
sMMio-=~ .... ~-. .... .-•co======='2io._ ...... ~eorT
ELEV 195
SECTION A-A SCALE
3-~.c=---~=-........ 3.0fT
MODEL STUDY OF SPILLWAY
ENID DAM, YOCONA RIVER, MISSISSIPPI
SPILLWAY PLAN AND PROFILE TYPE 3 2 DESIGN
![Page 92: MODEL STUDY OF SPILLWAY ENID DAM, YOCONA RIVER … · The model study of the spillway for Enid Dam, proposed for con struction on the Yocona River in Mississippi, was concerned with](https://reader034.fdocuments.us/reader034/viewer/2022042209/5eac857b9c764034935bb6cc/html5/thumbnails/92.jpg)
"U r ~ -1 m 1\) L11
.J Cl)
:::10
t-UJ UJ
"-
~
z 0 i= ~ UJ .J UJ
300r------,------~-------r-------r------,-------~------~------r-----~-------,------~-------r--~300
280
260
240
220
200
180
r-
r-
r-
1-
r-
z 0 t-
~ UJ .J UJ
~----~~----~------~------~------~------~------~------~------~------~----~------~--~180 99 +40 +80 100 + 20 +60 101 + 00 +40 +80 102 +20 +60 103 +00 +40 +80
'• TEST DATA
DISCHARGE 50,000 C f S TAILWATER ELEV 220.4
STATIONS
MODEL STUDY OF SPILLWAY
ENID DAM, YOCONA. RIVER, MISSISSIPPI
WATER-SURFACE PROFILE
T,YPE 32 DESIGN
![Page 93: MODEL STUDY OF SPILLWAY ENID DAM, YOCONA RIVER … · The model study of the spillway for Enid Dam, proposed for con struction on the Yocona River in Mississippi, was concerned with](https://reader034.fdocuments.us/reader034/viewer/2022042209/5eac857b9c764034935bb6cc/html5/thumbnails/93.jpg)
..J U)
::E
1-liJ liJ !...
~
z 0 i= ~ liJ ..J liJ
300~----~------~------~-------r------,-------~------~------r-------r-----~------~------~--~300
-
280
r-
260 ~
r-
240
r-
220
r--
200
I-
-WALL LEV 285.0 --.....
..J U)
::E
~ liJ liJ !...
~
z Q 1-~-liJ ..J liJ
180 ~----~~----~------~------~-------L------~------~------~------~------~----~------~--~180 99+40 +80 100+20
TEST DATA
DISCHARGE 25,000 C F S TAILWATER ELEV 216.0
+60 101+00 +40 +80
STATIONS
102+20 +60 103+00 +40 -1-80
MODEL STUDY OF SPILLWAY ENID DAM, YOCONA RIVER, MISSISSIPPI
WATER-SURFACE PROFILE
TYPE 32 DESIGN
![Page 94: MODEL STUDY OF SPILLWAY ENID DAM, YOCONA RIVER … · The model study of the spillway for Enid Dam, proposed for con struction on the Yocona River in Mississippi, was concerned with](https://reader034.fdocuments.us/reader034/viewer/2022042209/5eac857b9c764034935bb6cc/html5/thumbnails/94.jpg)
~ 3 ..J 0:
"' "-0 w z J a: w 1-z w u
::l! 0 a: "-1-w w "-
~
w u z ~ "' 0
200
200 101+00
ID ID ID
[] []
[] ID
ID --[]-[]
[][[]
[][[]
[[]ID IDID
SECTION. ALONG· CENTERLINE OF STILLING BASIN
SCALE
~~~~~------~'~====~~~ .... ~!•O~Ui NOTE: ELEVATIONS ARE IN FEET REFERRED TO M S L
BED MOLDED FLAT TO BASIN ELEVATION AT START OF TEST
~
=
106+50 107+00
STATION·
200
150
100
50
0
50
100
150
200 107+50 108+00 108+50 109+00 109+50 110+00
MODEL STUDY OF SPILLWAY ENID DAM, YOCONA RIVER, MISSISSIPPI
SCOUR PATTERN TYPE 32 DESIGN
DISCHARGE 50,000 C F" S TAILWATER ELEVATION 220.4
~ 3 ..J 0: "' "-0 w z J a: w 1-z w u
::l! 0 a: "-1-w w ... ~ w u z ~ <0 c
![Page 95: MODEL STUDY OF SPILLWAY ENID DAM, YOCONA RIVER … · The model study of the spillway for Enid Dam, proposed for con struction on the Yocona River in Mississippi, was concerned with](https://reader034.fdocuments.us/reader034/viewer/2022042209/5eac857b9c764034935bb6cc/html5/thumbnails/95.jpg)
~ ~ -' 0::
"' "-0 UJ z :::; a: w >z UJ u
;:; 0 a: "-
~
w u z
" "' 0
ISO
"' "' "' "' "' "' "' "' "' "! "! "' "' "' ;:: "' '" ,;
"' ~ ~ ~ .0 +
"' "' "' "' "' + 2 2 2 2 "' E!.,EV 19a:o 2 ;t~;·:
SECTION ALONG CENTERLINE OF STILLING BASIN
SCALE 2•l(,O-=:=-o-=:~---~20~==::"Ji---·-6•o-FEET
!'JOTE: ELEVATIONS ARE IN FEET REFERRED TO M S L
!?ED .~?Ll?~)? FL~T T~ ~ASIN ELEVATION AT START OF TEST
STATION
200
I 50
roo
50
MODEL STUDY OF SPILLWAY ENID DAM, YOCONA RIVER, MISSISSIPPI
SCOUR PATTERN TYPE 32 DESIGN
DISCHARGE 25,000 C F S TAILWATER ELEVATION 216.0
~ ~ -' -' 0::
"' "-0 w
"' -' a: UJ >--z UJ u
;:; 0 a: "-
>--w ::' ~
UJ u z
" "' 0
![Page 96: MODEL STUDY OF SPILLWAY ENID DAM, YOCONA RIVER … · The model study of the spillway for Enid Dam, proposed for con struction on the Yocona River in Mississippi, was concerned with](https://reader034.fdocuments.us/reader034/viewer/2022042209/5eac857b9c764034935bb6cc/html5/thumbnails/96.jpg)
l'i ~ -' ii (I)
"-0 w z J a: w f-z w u ::; 0 a: "-
f-w w "-
:0: w u z ~ !!l 0
200 200
150 150 M__ !fW._ [!U_ !fW._ ll_ M_ n___ M__ !..!JL._ L.M_ u__ u;___
5.0 ~ u_ 6.5 u_ 100
[[} [] tJL.._ M..-- tl_ ~ ~
[[} [[}
[[} LQ._._ 50 [[}
1.0 ·~ ML_ .La.-_ ~
[[} [] !Jl..-_ L.tL..._ ~ l..Q.._ Yl_ [].[]
0 -----IIJ [[} 4~.5~--~---'~·o _______ ·-----~-----------'~·o----------~-------------~~-------------------------[][]
~
50 . !.lL._
UL_
100 ~
~ !..L.f2_
150
200 101+00 102+50 103+00 103+50 104+00 104+50
"' 0> ..
SECTION ALONG CENTERLINE OF STILLING BASIN
SCALE
•';;:,o-==--=='i.---f.!•o'====='•'jo ___ ,j''o FEEi
NOTE: ELEVATIONS ARE IN FEET REFERRED TO· M S L
B,ED MoLDEo·• FLAT TO BA!'>IN ELEV~TION
VELOCITIES ARE IN FEET PER SECOND IN PROTOTYPE
l..f2_._
~
M_._
u__
!l.!l.--fli.__
105+00 105+50
STATION
LQ.._._ l..f2_._
w___ !.lL._
M.__.. M.__..
n___ M___
!.Yl.._ u._ J.JU.._ 1M_
106+00 106+50 107+00
LQ.._._
L.tL..._ 50
u_
§.4_ 100
£..Q_
~
ISO
200 107+50 108+00 108+50 109+00 109+50 110+00
MODEL STUDY OF SPILLWAY ENID DAM, YOCONA RIVER, MISSISSIPPI
BOTTOM VELOCITIES TYPE 32 DESIGN
DISCHARGE 50,000 C F S TAILWATER ELEVATION 220.4
l'i ~ -' ii (I)
"-0 w z J a: w f-z w u
::;
~ "-f-w w "-
:0: w u z ~ (I)
i5
![Page 97: MODEL STUDY OF SPILLWAY ENID DAM, YOCONA RIVER … · The model study of the spillway for Enid Dam, proposed for con struction on the Yocona River in Mississippi, was concerned with](https://reader034.fdocuments.us/reader034/viewer/2022042209/5eac857b9c764034935bb6cc/html5/thumbnails/97.jpg)
-o r )> -I rn w 0
~ ~ ...J 0:: "' .. 0 w z J a: w 1-z w u
~ 0 a: .. 1-w w .. ~ w u z ~ !!l 0
200 I I
150
100
50
0
50
100
150
r- ~7 LLJ[[] [[][[]
r-[[][]
[][]
[][]
[][] --------[] ~-
[] []
[] []
[[] - [[] [[]
[] [[][[] rn
~~
I I I I I
YL- u_ y_ g_g_
(0. .!..Q__ 1.0 /.0
!:fl.._ !:.!!._ YL-
!.Q_ l!L_. !Q_ !:!L_
.!..Q__ L9.._. t1L_
I I I I 200
-I 50
-
I
~ ~ ...J
00 0::
"' .. 0
50 w z J a: ~
~---.ML-------~-----~--------------------------------- 0
z w u
f2.._ Y2._
y_ .!:.1!._ .fQ_
t1L_ liL-
2.~ li_.. .i!2_
u_ ~ ~
I
1.:.!2_
.!.:Q__
ilL_
.Y2...._..
E.:..P_
I-50 w
w "-
I
-I
w 00 li
50
~ "' 1'i
I I I I I I j_ I I I I 200 200
101+00 IOI+SO 102+00 102+50 103+00 103+50 104+00 104+50 105+00 105+50 106+00 106+50 107+00 107+50 LOS+OO 108+50 109+00 109+50 110+00
SECTION ALONG CENTERLINE OF STILLING BASIN
SCALE 201i..=:::>~-=:::'i. __ _.20~==~40i.._ ..... 80 FEET
NOTE: ELEVATIONS ARE IN FEET REFERRED TO M S L
BED MOLDED FLAT TO .BASIN ELEVATION
VELOCITIES ARE IN FEET PER SECOND IN PROTOTYPE
STATION
ELEV 195.0
MODEL STUDY OF SPILLWAY ENID DAM, YOCONA RIVER, MISSISSIPPI
BOTTOM VELOCITIES TYPE 32 DESIGN
DISCHARGE 25,000 C F S TAILWATER ELEVATION 216.0
![Page 98: MODEL STUDY OF SPILLWAY ENID DAM, YOCONA RIVER … · The model study of the spillway for Enid Dam, proposed for con struction on the Yocona River in Mississippi, was concerned with](https://reader034.fdocuments.us/reader034/viewer/2022042209/5eac857b9c764034935bb6cc/html5/thumbnails/98.jpg)
'"U r )> -1 fT1
li' 3 ..J ii: "' "-0 UJ z ::i a: w 1-z UJ u :::;; 0 a: "-
1-UJ UJ ... :!:: UJ u z >5 "' c
200
150 150
100
[]
[] 50 []
[] []
[] []
-~[]-[] 0 [][]
[] []
[] []
[] []
[]
50
----216--
2ooL------L------~------~-----L----~~----~~----~------~----~------~------L------L------~------~----~------~----~~----..J2oo 101+00 101+~0 102+00 102+50 103+00 103+50 104+00 105+50 106+00 106+50 107+00 107+50 108+00 108+50 109+00 109+50 110+00
~ ·~, J J I ! '"" ""' · ·. ··· · ·_; ~~-~ .. ~~{;f~~::,~·y~_-~~-~_(:~_;~~~-~\.:;~/-~}_~!~-:~-.Yfr'~\~:~~~ :<: · ~ · -···· · · ()
.::-::
100.01
SECTION ALONG CENTERLINE OF STILLING BASIN
SCALE
2~0-=::::.-=:·--..J1.20~==~""---,j2•0FEEi
NOTE: ELEVATIONS ARE IN I'EET REFERRED TO M S L
BED MOLDED FLAT TO BASIN ELEVATION .AT START OF TEST
STATION
ELEV 195.0
MODEL STUDY OF SPILLWA't ENID DAM, YOCONA RIVER, MISSISSIPPI
SCOUR PATTERN TYPE 33 DESIGN
DISCHARGE 50,000 C F S TAILWATER ELEVATION 220.4
li: 3 ..J ii:
"' "-0 UJ z ::i a: UJ 1-z w u
:::;;
~ "-1-UJ UJ ... :!:: UJ u z >5 "' 0
![Page 99: MODEL STUDY OF SPILLWAY ENID DAM, YOCONA RIVER … · The model study of the spillway for Enid Dam, proposed for con struction on the Yocona River in Mississippi, was concerned with](https://reader034.fdocuments.us/reader034/viewer/2022042209/5eac857b9c764034935bb6cc/html5/thumbnails/99.jpg)
"U r )> -l m
w 1\)
138.08 1
0 0 + 0 0
156.42 1 60.48 1
HALF PLAN
PROF.ILE _
SCALE
··--.C~--~=J ........ 6~0=======J'2•0 ....... 1.80FT
ELEV 195
45.0~
DETAIL OF DEFLECTOR
SCALE
~~~~-==--llllio'====:i's----3-oFT
MODEL STUDY OF SPILLWAY
ENID DAM, YOCONA RIVER, MISSISSIPPI
SPILLWAY PLAN AND PROFILE
TYPE 34 DESIGN
![Page 100: MODEL STUDY OF SPILLWAY ENID DAM, YOCONA RIVER … · The model study of the spillway for Enid Dam, proposed for con struction on the Yocona River in Mississippi, was concerned with](https://reader034.fdocuments.us/reader034/viewer/2022042209/5eac857b9c764034935bb6cc/html5/thumbnails/100.jpg)
_J
1/)
~
1-w w t...
~
z 0 i= ~ w _J w
300 r-------r-------~------~------~------,-------~------~-------.-------r------~------~------~--~ 300
~ WALL "LEV 285.C--.
280
-
260
-
240
;-
220
r-:-
2001-t-'
1=-1-
ISO' 99+40 +80 100+20
TEST DATA
DtSCHARGE 50,000 C F. S TAILWATER ELEV 220.4
+60 101+00 +40 +80 102+20
STATIONS SECTION ALONG ct. OF SPILLWAY
-
280
-_J
1/) 260
~
1-- w
UJ t...
240 z -z Q 1-
~ 220 w
_J w
-
200
-.,(:
ISO +60 103+00 +40 +80
MODEL STUDY OF SPILLWAY
ENID DAM, YOCONA RIVER, MISSISSIPPI
WATER-SURFACE PROFILE
TYPE 34 DESIGN
![Page 101: MODEL STUDY OF SPILLWAY ENID DAM, YOCONA RIVER … · The model study of the spillway for Enid Dam, proposed for con struction on the Yocona River in Mississippi, was concerned with](https://reader034.fdocuments.us/reader034/viewer/2022042209/5eac857b9c764034935bb6cc/html5/thumbnails/101.jpg)
"U r )> ~ ITI
...J <I)
~
I-LJJ LJJ "-
~
z 0 i= ~ LJJ ...J LJJ
300r-------r-------~------T-------~------~------~--~---r------~------~------~------~------~~~ 300
280
260'
240
220
200
180
-WALL LEV 285.01-----...
280
r- -...J <I)
260 ~
f-- LJJ LJJ
r-LL
240 ~
WALL EL v 230.0-z -- Q I-
r-~
220 LJJ ...J LJJ
1- -
f-
~------~------~------~------...l-------~------~------~------~------~------~-------...l------~~-...1180 99+40 +80 100+20
TEST DATA
DISCHARGE 25,000 C F S TAILWATER. ELEV 216.0
+60 101+00 +40 +80 102+20
STATIONS SECTION ALONG t. OF SPILLWAY
+60 103+00 +40 +80
MODEL STUDY OF SPILLWAY
ENID DAM, YOCONA RIVER, MISSISSIPPI
WATER-SURFACE PROFILE
TYPE 34 DESIGN
![Page 102: MODEL STUDY OF SPILLWAY ENID DAM, YOCONA RIVER … · The model study of the spillway for Enid Dam, proposed for con struction on the Yocona River in Mississippi, was concerned with](https://reader034.fdocuments.us/reader034/viewer/2022042209/5eac857b9c764034935bb6cc/html5/thumbnails/102.jpg)
"' u %
~ "' 0
lEJm ... {[] []lEJ [][]
[]lEJ [][]
--·-·[]--.. []
lEJlEJ lEJ . IIJ {[]·-[]{[]
[]
~~~~--~~~~~~~~~~--~~~~~~--+-~~~~~----~--~~----~~~--~----~------~----~------~----~----~200 102+00 .102+50 104+50 105+00 105+50 106+00 106+50 107+00 107+50 108+00 108+50 109+00 109+50 110+00
STATION
NOTE: · Et.EVATI0NS ARE ·rN F"EET. REF"ERRED TO 1\,fs L
- BED MOLDED F"LAT- TO BASIN ELEVATION- AT START OF TEST
MODEL STUDY OF SPILLWAY ENID DAM, YOCONA RIVER, MISSISSiPPI
SCOUR PATTERN TYPE 34 DESIGN
DISCHARGE 50,000 C-fS TAILWATER ELEVATION 220.4
"-0
"' z J
·a: "' J-z "' u
"' u z ~
.II! ·0
![Page 103: MODEL STUDY OF SPILLWAY ENID DAM, YOCONA RIVER … · The model study of the spillway for Enid Dam, proposed for con struction on the Yocona River in Mississippi, was concerned with](https://reader034.fdocuments.us/reader034/viewer/2022042209/5eac857b9c764034935bb6cc/html5/thumbnails/103.jpg)
i:i r ~~ ['tl'
~. CD'·
l;: ~ ..J 0: <11
"-0
"' z ::i a:
"' .... z "' u
::; 0
~ .... "' "' "-
"' w u z ~ 2· ,,.
"·
200
150
50
SECTION ALONG CENTERLINE OF' STILLING BASIN
SCALE'
2~0-=:=-o=·!l.o---~20'===~--.-·S~?.FEET
~OTE: ELEVATIONS ARE IN FEET REFERRED T0 M S L
a~~ .. M.Q~p"E£!! ~1:-~T, }0_ ~A~~N·"-~-~EV~T.I~~- AT START Of TEST
~
106+50
STATION
ELEV 195.0
107+00
200
150
100
50
0
·so
200 107+50 109+50 IIO+bO
MODEL STUDY OF SPILLWAY ENID DAM, YOCONA RIVER, MISSISSIPPI
SCOUR PATTERN TYPE 34 DESIGN
DISCHARGE 25,000 TAILWATER ELEVATION
C F S 216.0
l;: ~ ..J 0: <11
"-0
"' ~ ..J a: w .... z "' u
::; 0 a: "-
.... "' "' "-
"' w u z ~ <11 0
![Page 104: MODEL STUDY OF SPILLWAY ENID DAM, YOCONA RIVER … · The model study of the spillway for Enid Dam, proposed for con struction on the Yocona River in Mississippi, was concerned with](https://reader034.fdocuments.us/reader034/viewer/2022042209/5eac857b9c764034935bb6cc/html5/thumbnails/104.jpg)
'"a r )> -I m
l< 15 -' 0: U)
"-0
"' <: -' a: "' 1-z "' u
0 ::; 0 a: "-
1-
"' "' "-
<:
"' u z ~ '!1 0
.3.0 []
[] []
[] []
[] []
[]
~~---~---~~---~---~---~
~~ ~ ~ ~ ~ ~ ~
,YL._~- !.!2.._ Y!.._ M._ ~ ~ ~
I 50
l(
15 ------------------~~--------------~~--iiOO ~
U)
"-0
"' z :::;
[] [][]
-~Ul_ :_!A._ £2.- ~ ~ ~ ~ ei 1-z "' --[[]-
[] 5~~__!.J!___-~---Y2-----'--0--~~--4_-5 ______________________________ ------- u
[[][]
[][]
[][] ITT
[] []
~YL- -~ LQ__ LQ__ y_ ~ 1..d_
!.,Q__~ 'YL..- !A___._ M_ ~ ~ li_.
!A_~ ~ ~ ~ ~ ~ ~
[[] 2.0 U!..._~_g____~_ti_ ___ ~-~-~
~
12.5
.,. "' "' "' 0> "' .. "! .. ,; ~ ~ 0
+ + +. "' '01 "' 2 2 2
ELEV 198.0
SECTION ALONG CENTERLINE OF STILLING BASIN
SCALE 20J0.=-::::'i·--·201i'!::==='4lii0 ___ r/t.6'0FEEi
NOTE: ELEVATIONS ARE IN F'EET REFERRED TO M 5 L
BED· MOL.DED FLAT TO· BASIN ELEVATION
VELOCITIES ARE IN FEET PER SECOND IN PROTOTYPE
10.0 1M_ M._ M.,_. M_
!!2.:2-- 11.0 ~ ~ ~ ~
STATION
100
150
MODEL STUDY OF SPILLWAY ENID DAM, YOCONA RIVER, MISSISSIPPI
BOTTOM VELOCITIES. TYPE 34_ DESIGN
DISCHARGE 50,000· C F S TAILWATER -ELEVATION 220.4
::;
~ "-1-w "' "-
~
"' u z ~ </)
0
![Page 105: MODEL STUDY OF SPILLWAY ENID DAM, YOCONA RIVER … · The model study of the spillway for Enid Dam, proposed for con struction on the Yocona River in Mississippi, was concerned with](https://reader034.fdocuments.us/reader034/viewer/2022042209/5eac857b9c764034935bb6cc/html5/thumbnails/105.jpg)
-o r )> ...; fT1
w ())
~ ~ .J 0: "' ... 0
"' z ::;
"' ... .... z. ... u
:1 0
"' ... .... w "' ... :!:
"' u z ~ "' 0
200
~!:!.:.?_ 1M_ !.!:!2._ !M_ t!M!- M_ !l,Q...._ ?.4- ~ZL- .M..- £L__ ?.1- l!l_ ll_ ?!L_
~~--- !:.2__ M_ -~--~--1.d.--~
u_~ ~ ~ !d.- li_ il-- M-
;g_~ ~ ~ y_ li!.- YL_ YL_
~lil_ YL_ ~ ~ M-- li2_ liL-
~YL- M.--. ~ ~ ~ M.- ~
M-¢..- ~ YL- u__ ll_ liL- M._
lil_~ 9-' ~ ~ ~ M?- id_
~~ ~ M-- M_ __ u.,_ __ id__id_
{LZQ;__ li!.-. li- ll- ll- lQ._ EL_ ~~ 11.5 !.LL. !1M!- ~ £Q._ ll._
ISO
~ ~
----------------------lioo ::! il;
so
100
150
... 0
"' z ~ w .... ~ u
w u z ~-
"' 0
~oL---~~----~~----~~~~~--~~~~~~--~~~~~~~~~~~~~~~~--~~~~~~----~----~----~~----~----~200 . 101+00 103+SO 104+00 104+SO 105+00 105+50 106+00 106+50 107+00 107+50 108+00 IOB+SO 109+00 109+50 110+00
SECTION ALONG CENTERLINE OF STILLING BASIN
SCALE
~•-==--=~ .... .-f~======ffl~ .... _.,onfT
NOTE: ELEVATIONS ARE IN FEET REFERRED TO M S L
BED MOLDED FLAT TO BASIN ELEV,ATION
VELOCITIES ARE IN FEET PER SECOND IN PROTOTYPE
STATION
MODEL STUDY OF SPILLWAY ENID DAM, YOCONA RIVER, MISSISSIPPI
BOTTOM VELOCITIES TYPE 34 DESIGN
DISCHARGE 25,000 C F S TAILWATER ELEVATION 216.0
![Page 106: MODEL STUDY OF SPILLWAY ENID DAM, YOCONA RIVER … · The model study of the spillway for Enid Dam, proposed for con struction on the Yocona River in Mississippi, was concerned with](https://reader034.fdocuments.us/reader034/viewer/2022042209/5eac857b9c764034935bb6cc/html5/thumbnails/106.jpg)
., r ~ rn c.u 10
l( ~ .J a: "' "-0 w z :::; a: w 1-z w u
::li 0 a: "-
1-w w "-
~ w u z ~ "' 0
[[]
[[]
0
[[]
[] 50
IIJ
roo
150
150
l(
~ .J
tOO 0::
50
0
50
"' "-0 w z :::; a: w rz t!-
w 100 ~
~ "' a
200 - 200 101+00 101+50 102+00 102+50 103+00 103+50 104+00 104+50 105+00 105+50 106+00 106+50 107+00 107+50 108+00 108+50 109+00 109+50 110+0.0.
SECTION ALONG CENTERLINE OF STILLING BASIN
SCALE 20··-=::-.-='----"'zo'===:340 ___ .. ,~ FEET
NOTE: ELEVATIONS ARE IN F"EET REF" ERRED TO M S L
BED MOLDED FLAT TO BASIN ELEVATION AT START Of TEST
STATION
ELEV 195.0
MODEL STUDY OF SPILLWAY ENID DAM, YOCONA RIVER, MlSSI.SStPPl
SCOUR PATTERN TYPE 35 DESIGN
DISCHARGE 50,000 C F S TAILWATER ELEVATION 220.4
![Page 107: MODEL STUDY OF SPILLWAY ENID DAM, YOCONA RIVER … · The model study of the spillway for Enid Dam, proposed for con struction on the Yocona River in Mississippi, was concerned with](https://reader034.fdocuments.us/reader034/viewer/2022042209/5eac857b9c764034935bb6cc/html5/thumbnails/107.jpg)
'"0 r )> 200
-:-1 fTl
,t:.. 0
lc ~ _J
a: U)
"-0 w :<': 50 _J a: w f-z w u
0 ::; 0 a: "-
f-lU w "-
:<': lU u z
" f-"2 0
~~2~~~~~====== ,-- 210 ~-~~~--~---205
r::=:=====~~====~~======:2oo---------------------l- 195-------------~
[[][]
[][[] [[]
[][]
[][[]
[][] --[]
[[]!IJ []!I]
!IJ[[] []
SECTION ALONG CENTERLINE OF STILLING BASIN
SCALE
·-=-d·---20'====-----60FEET. NOTE: ELEVATIONS ARE IN FEET REFERRED TO M S L
BED MOLDED FLAT TO BASIN ELEVATION
STATION
ELEV 195.0
ISO
5o
MODEL STUDY OF SPILLWAY ENID DAM, YOCONA RIVER, MISSISSIPPI
SCOUR PATTERN TYPE 36 DESIGN
DISCHARGE 50,000 C F S
TAILWATER ELEVATION 220.4
~ 3 _J _J
a: <1)
"-0 lU
:<': _J
a: w t-z w u
::; 0 a: "-
f-w w "-
'-' w u z ;<: U)
0
![Page 108: MODEL STUDY OF SPILLWAY ENID DAM, YOCONA RIVER … · The model study of the spillway for Enid Dam, proposed for con struction on the Yocona River in Mississippi, was concerned with](https://reader034.fdocuments.us/reader034/viewer/2022042209/5eac857b9c764034935bb6cc/html5/thumbnails/108.jpg)
~ ~ _.J
0:
"' "-0
"' :<!: _.J
a: "' f-z "' u
:;; 0 a: "-
f-
"' "' "-
~
"' U.; z .: f-<I! 0
-
200
--·
150
100
[[J[]
[][] .. , [] [][[J [] [][]
--[]-[] [[] ·[] .
to[] •[] [!] ... [][] ·[] [][[]
1---------215--------
200--------
-----195-----------
"-0
"' 50 ~ _.J
a:
"' f-z "' u
>-"' ~
"' 100 ~
150
: "' 0
·:~~gll+_0_0----10-I+LS-O----I-02_+L_OO~--I0_2j+~'s~0----10~3l+-O-O---I-0-3L+-5-0-----L----l-j_~--~~~----~~~_j--~~-l-------L~-----L------j_-----I0-8~+-5-0---I-0-9L+-O-O---I-09-+L_50--~II-OJ+5go .J
SECTION ALONG CENTERLINE OF STILLING BASIN
SCALE 2<~0-==-•"c··='·o~-... .,f;!20~==~:.,.--.,::·ao F'Ein
NOTE: ELEVATIONS ARE IN F'EET REFERRED TO M'S L
SED,. MQLD£0 FL.:AT TO BASIN: ELEVATION
STATION
MODEL STUDY OF SPILLWAY ENID DAM, YOCONA RIVER, MISSISSIPPI
SCOUR PATTERN TYPE 37 DESIGN
DISCHARGE 50,000 C F S TAILWATER ELEVATION 220:4
![Page 109: MODEL STUDY OF SPILLWAY ENID DAM, YOCONA RIVER … · The model study of the spillway for Enid Dam, proposed for con struction on the Yocona River in Mississippi, was concerned with](https://reader034.fdocuments.us/reader034/viewer/2022042209/5eac857b9c764034935bb6cc/html5/thumbnails/109.jpg)
1J r ~ m
~ 1\)
~ ;s .J ;;:
"' ... 0
"' z :i a: w .... z "' 0
:I! 0 a: ... .... "' "' ... ;!!;
"' u z ~ "' 0
200
ISO
IT] ([]
[I] EO tb 50 ITJ· ... ([] []J . . ([] [IJ. .. [I]
0 --[I]-[]([] [I]([]
so: [[)
([]
[I] ([]
([] .. 100
ISO
200 101+00
SECTION ALONG CENTERLINE Of STILLING BASIN
SCALE 20-:=:oilll::=::ioi ___ 20i:'::::===40-··--·20F'EEt
'NOtE: ELEVATIONS ARE IN f'EET REf'ERRED TO M S L
BED MOLDED FLAT TO .BASiN ELEVATION
STATION
ELEV !95.0
~-·--=
MODEL STUDY OF SPILLWAY
50
... 0
"' z ::; a: ~ z "' u
.... "' "' ... ~
"' 100 ~
150
f! "' 0
ENID DAM, YOCONA RIVER, MISSISSIPPI
SCOUR PATTE'RN TYPE 38 DESIGN
DISCHARGE 50,000 C F S TAILWATER ELEVATION 220.4
![Page 110: MODEL STUDY OF SPILLWAY ENID DAM, YOCONA RIVER … · The model study of the spillway for Enid Dam, proposed for con struction on the Yocona River in Mississippi, was concerned with](https://reader034.fdocuments.us/reader034/viewer/2022042209/5eac857b9c764034935bb6cc/html5/thumbnails/110.jpg)
'"U r )> ~ fTI
~ ~ ..J ii: <I) .. 0
"' z ::; a:
"' ... z "' u
0 :::;; 0 a: .. ... "' "' .. 1:
"' u z ;! !Q c
[]
[]
[]
--[]
[IJ
[]
[]
[]
103+50 104+00 104+50 105+00
"' ~ "' "' "' <0 <0 "' "' "' <0
"' 0 "' + + + N "' "' 2 2 2
ELEV 195 0
SECTION ALONG CENTERLINE OF STILLING BASIN
SCALE
2:~0-==--="'---..il20~==~4\iio0 __ ..,~60FEEi
NOTE: ELEVATIONS ARE IN F"EET REF"ERRED TO M S L
BED MOLDED F"LAT TO BASIN ELEVATION
105+50 106+00 106+50
STATION
200
150
100
MODEL STUDY OF SPILLWAY ENID DAM, YOCONA RIVER, MISSISSIPPI
SCOUR PATTERN TYPE 38 DESIGN
DISCHARGE 25,000 TAILWATER ELEVATION
C FS 216.0
1;: ~ ..J ii: <I) .. 0
"' z ::; a: "' ... z "' u :::;; 0 a: .. ... "' "' lL
1:
"' u z ;! <I)
0
![Page 111: MODEL STUDY OF SPILLWAY ENID DAM, YOCONA RIVER … · The model study of the spillway for Enid Dam, proposed for con struction on the Yocona River in Mississippi, was concerned with](https://reader034.fdocuments.us/reader034/viewer/2022042209/5eac857b9c764034935bb6cc/html5/thumbnails/111.jpg)
"U r )> -1 rn
l< ~ .J a: "' "-0
"' z J a:
"' ... z "' u :;; 0 a: "-... "' "' "-
~
"' u z ~ "' 0
200~----~------r------.------.------r------.------.------.------.------.------.------.------.------.------.----~.------r----~
0
50
100
150
[DIIJ [DIIJ [DIIJ [DIIJ [DIIJ
--[]--IIJ ~---~'~0 ___________ --LQ__ ________ ~-----------------------------------------------------
[DIIJ [DIIJ [[]II]
IIJIIJ [DIIJ
ID
...1.:!2_
...l.J2-_
...LQ__
..z.g_
-fH----~
SECTION ALONG CENTERLINE OF STILLING BASIN
SCALE
ZO~=-::::J:..--Ji.ZO'====·'i\o:..--.. 6'0FEE'T NOTE: ELEVATIONS ARE IN FEET REFERRED TO M S L
BED MOLDED FLAT TO BASIN ELEVATION
VELOCITIES ARE IN FEET PER SECOND IN PROTOTYPE
...Y2_
_li4.
_il_
_Lf4___
~ ..1L.§.._
ELEV 195.0
-LQ.._
...J..,Q_
~
J.L_
_u_ ~
STATION
1~0
150
MODEL STUDY OF SPILLWAY ENID DAM, YOCONA RIVER, MISSISSIPPI
BOTTOM VELOCITIES TYPE 38 DESIGN
DISCHARGE 50,000 TAILWATER ELEVATION
C F S
220.4
... 0
"' z J a: "' 1-z "' u
![Page 112: MODEL STUDY OF SPILLWAY ENID DAM, YOCONA RIVER … · The model study of the spillway for Enid Dam, proposed for con struction on the Yocona River in Mississippi, was concerned with](https://reader034.fdocuments.us/reader034/viewer/2022042209/5eac857b9c764034935bb6cc/html5/thumbnails/112.jpg)
-o r )> -; fT1
?< ~ _J
a: "' "-0 w z ::i a: w >-z w u ::; 0 a: "-
>-w
"' "-
~
"' u z ~ "' 0
200
150 ~ J1L__ _£,g_ __5__,§_ ~ ___li1_
----~ 1..5 1.0 100
__f_,_f2_,__ __Lfl._ ____LL
[] ...Lf2__ ~ ....L!l_
50
~-~--------~----------~1.-o _____________________________________________________ _
[] []
[] --[]-[] 0
[][]
[][]
UJ[] 50 []UJ
___u;_ -LQ..__ __L_Q__
0
50
~ ....LP_ ~
~ -.LQ.__ ...l...f4_
[]
100 ~ __lid__ ____LQ_. 100
~ ~ ~ .LL.. .--.li2_ ~
150 150
200L_ ____ _J ______ _L ______ !_ ____ _J ______ _L ______ !_ ____ _J ______ _L ______ l_ ____ _J ______ _L ______ l_ ____ _J ______ _L ______ l_ ____ _J ______ -l ____ __J200
~01+00 101+50 102+00 102+50 103+00 103+50 104+00 104+50 105+00 105+50 106+00 106+50 107+00 107+50 108+00 108+50 109+00 109+50 110+00
:.:· ... ·::···
·I SECTION ALONG CENTERLINE OF STILLING BASIN
SCALE
2<~0-==--=~---,ji20~==~40::..---=60FEET
NOTE: ELEVATIONS ARE IN F"EET REF"ERRED TO M S L
BED MOLDED F"LAT TO BASIN ELEVATION
VELOCITIES ARE IN F"EET PER SECOND IN PROTOTYPE
ELEV 195.0
STATION
MODEL STUDY OF SPILLWAY ENID DAM, YOCONA RIVER, MISSISSIPPI
BOTTOM VELOCITIES TYPE 38 DESIGN
DISCHARGE 25,000 C F S TAILWATER ELEVATION 216.0
?< ~ _J
a: "' "-0 w z ::i a: w >-z w u
::; 0 a: "-
>-w w "-
~ w u z ~ "' 0