Model GT 1175 Electrical Installation Manual **with U30 ... · Part #15-10596-30 Rev. 1-10-14 iv...
Transcript of Model GT 1175 Electrical Installation Manual **with U30 ... · Part #15-10596-30 Rev. 1-10-14 iv...
S82 W18717 Gemini DriveMuskego, Wisconsin 53150
Phone: (877) 622-2694Fax: (888) 679-3319
www.nabcoentrances.comTechnical Support: (866) 622-8325
Part #15-10596-30 Rev. 1/10/14
WARNING• Turn OFF all power to the Automatic Door if a Safety System is not working.
• Instruct the Owner to keep all power turned OFF until corrective action can be achieved by a NABCO trained technician. Failure to follow these practices may result in serious consequences.
• NEVER leave a Door operating without all Safety detection systems operational.
Model GT 1175 Electrical Installation Manual
**with U30 Microprocessor Controller** (with Revision D Software)
120 VAC
LABEL ON U30 CONTROL
AC115V ± 10%50 / 60 Hz
BLACK (HOT)
SCREW TO HEADER
WHITE (COMMON)
GROUND LUG
MADE IN JAPAN
(24-11327)DS-150NA
GYRO TECH
ON/OFF POWER SWITCH
TRA
NS
FOR
ME
R
AMP
5TB1
NOISEFILTER
TB2
T1
S1
ZNR2ZNR1
AUXILIARY 120 VACPOWER WIRES(THESE WIRES NORMALLY COILED AND TIED UP)
MOTOR/OPERATOR P/N 24-11327
ACTIVATION SIGNAL
OUTPUT SIGNAL
OFF
OFF
ON
ON
FULLY CLOSED
OPENING
FULL OPEN
CLOSINGFULLY CLOSED
OUTPUT: 0 = ELECTRIC STRIKE OUTPUT
OUTPUT TIMER0 = (DO NOT USE)1 = (DO NOT USE)2 = (DO NOT USE)3 = ELECTRIC STRIKE FUNCTION
U30 ELECTRIC STRIKE OUTPUT SIGNALHANDY TERMINAL: AUX OUTPUT = 0, OUTPUT TIMER = 3, ROCKER SWITCH SETTING: ONE WAY OR NIGHT MODE
OUTPUT TIMER1.0 SEC
3 SEC
U30 CONTROL P/N 24-8901-30POWER SUPPLY P/N 14-11741
GROUND HARNESSP/N 14-11872
POWER SUPPLY HARNESSP/N 14-11874
VIOLET
GRAY (OUT A)
TERMINAL ON U30 MAIN HARNESS
P/N 24-11877WIRING FOR ELECTRIC LOCK ONLY SHOWN FAIL SECURE LOCK ASSY.
P.N. 22-10522-03
FAILSECURE
VIOGRY
WHTBLK
1
6
110V
20VA
C 50
/60H
z
Microprocessor Controller248901-
GYRO TECHHOLD OPEN
NIGHT
ONE WAYTWO WAY
MODEM1M0OpenGnd
OpenOpen
OpenGnd Gnd
Gnd
Mode SW Usage
Adjustments to the door can only be madewith the NABCO Handy Terminal.
CAUTION
To maintain warranty,repairs must be made by authorized NABCO facilities.
Do not disassemble the control box.There are no user serviceable parts inside.
POW
ER・2
PIN
DIC
ATO
RS 61
6B
H
62
BA
POWER
ERROR
MOTOR・12PNo.WARNING
To protect against risk of fire or electric shock,use only the certified NABCO power supply.
RE
LATE
D D
EV
ICE
S・1
6P
HANDY TERMINAL・6P
Mode Switch (see Mode SW Usage shown left)
617
6B
12VDC+12VDC-(Common)Interior ActivationHolding Beam
M0H
M1
SLS
62
BA
Exterior Activation
Sidelite Presence SensorBreakout Detector
1234567891011
Reduced Opening Switch
No.FUNCTION [SLIDING DOOR]
712VDC-(Common)
OUT.COUT.BOUT.AN/O
N/CCommon
Contact Output (Class2 Load only)30V(42.4Vpeak)max.5Amax.(0-20V), 3.2Amax.(20-30V)
OUTAuxiliary Output (Open-Collector)
SQSequential Activation
1615141312
12VDC-COMMONAuxiliary Output (Open-Collector)
Sequential Activation
5Amax.(0-20V), 3.2Amax.(20-30V)30V(42.4Vpeak)max.Contact Output (Class2 Load only)
FUNCTION [SLIDING DOOR]
REDUCED OPENING SWITCH
Breakout DetectorSidelite Presence Sensor
Exterior Activation
HOLDING BEAMINTERIOR ACTIVATION12VDC-(COMMON)12VDC+
Mode Switch (see Mode SW Usage shown left)
CommonN/CN/O
SQ
OUT
OUT.AOUT.BOUT.C
7
SYMBOL
BA
62
SLS
M1
HM0
6B
9DC12V761
1213141516
No.
1110987654321
RE
LATE
D D
EV
ICE
S -
16P 1
234567891011
1615141312
1234567891011
1615141312
SYMBOL9DC12V
HANDY TERMINAL HARNESS P/N 14-11837
DN 0552
THIS PAGE IS INTENTIONALLY LEFT BLANK
Rev. 1-10-14 Part #14-10596-30www.NabcoEntrances.com� Electrical�Installation�Manual�U-30�Control
i
Table of Contents
Warning Labels . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . iiiGeneral Safety Recommendations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . iv
CHAPTER 1: SCOPE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-5
Section 1a: To�the�Installer . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-5
Section 1b: Objective . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-5
CHAPTER 2: GETTING STARTED . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-6
Section 2a: About�the�U30�Microprocessor�Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-6
Section 2b: Electrical�Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-6
Section 2c: Output�Power�Guidelines . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-7
Section 2d: Header�Layout . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-7
CHAPTER 3: CONNECT INCOMING 120 VAC WIRES . . . . . . . . . . . . . . . . . . . . . . . . . . .3-9
CHAPTER 4: IDENTIFY OPERATING WIRES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-10
Section 4a: 16�Pin�Controller�Terminal�Block�Assignments��. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4-10
Section 4b: Sensor�Wire�Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4-11
Section 4c: Rocker�Switch�Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4-12
CHAPTER 5: WIRING DIAGRAMS (SURFACE APPLIED SLIDERS) . . . . . . . . . . . . . . . 5-14
Section 5a: (2)�Acusensors�and�(1)�Holding�Beam . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5-14
Section 5b: (2)�Optex�I-One�and�(1)�Holding�Beam . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5-15
Section 5c: (2)�Acusensors,�(1)�Holding�Beam�and�(1)�Breakout�Beam�Control . . . . . . . . . . . . . . . .5-16
Section 5d: (2)�Optex�I-One,�(1)�Holding�Beam�and�(1)�Breakout�Beam�Control . . . . . . . . . . . . . . .5-17
Section 5e: (2)�Wizard�G3,�and�(1)�Holding�Beam . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5-18
Section 5f: (2)�Wizard�G3,�(1)�Holding�Beam�and�(1)�Breakout�Control . . . . . . . . . . . . . . . . . . . . . .5-19
Electrical�Installation�Manual�U-30�Control� www.NabcoEntrances.comPart #14-10596-30 Rev. 1-10-14
ii
CHAPTER 6: INFRARED BEAM WIRING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-20
Section 6a: Wiring�(1)�Holding�Beam . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6-20
Section 6b: Wiring�(2)�Holding�Beams . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6-21
Section 6c: Wiring�Holding�Beam�for�Breakout . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6-22
CHAPTER 7: ELECTRIC LOCK WIRING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7-23
Section 7a: Adjust�the�Strike. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7-23
Section 7b: U30�with�Fail�Safe�Electric�Lock . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7-24
Section 7c: U30�with�Fail�Secure�Electric�Lock . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7-25
Section 7d: U30�with�Magnetic�Lock . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7-26
CHAPTER 8: CUSTOM WIRING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-27
Section 8a: U30�Configured�for�Remote�Control�of�Modes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8-27
Section 8b: Sidelite�Sensors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8-28
Section 8c: U30�Using�Card�Readers�or�other�Secure�Activation�Devices . . . . . . . . . . . . . . . . . . . . .8-29
CHAPTER 9: TROUBLESHOOTING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9-30
CHAPTER 10: RETURN POLICY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10-31
Section 10a: How�to�Print�and�Fill�out�a�Return�Material�Tag . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10-31
Rev. 1-10-14 Part #15-10596-30www.NabcoEntrances.com� Electrical�Installation�Manual�U-30�Control
iii
WARNING LABELS
Warning labels are universal and used to alert an individual of potential harm to one’s self or to others. The following warning labels are listed in a hierarchy order that defines the most potential danger first, and the least potential danger last. Please refer to this page in the event that a warning label is displayed within this manual and further definition needs to be explained.
Indicates potentially dangerous situations. Danger is used when there is a hazardous situation where there is a high probability of severe injury or death. It should not be considered for property damage unless personal injury risk is present.
Indicates a hazardous situation which has some probability of severe injury. It should not be considered for property damage unless personal injury risk is present.
Indicates a hazardous situation which may result in a minor injury. Caution should not be used when there is a possibility of serious injury. Caution should not be considered for property damage accidents unless a personal injury risk is present.
Notice: Indicates a statement of company policy as the message relates to the personal safety or protection of property. Notice should not be used when there is a hazardous situation or personal risk.
Note: Indicates important information that provides further instruction.
DANGER
WARNING
CAUTION
Electrical�Installation�Manual�U-30�Control� www.NabcoEntrances.comPart #15-10596-30 Rev. 1-10-14
iv
GENERAL SAFETY RECOMMENDATIONS
Do not install, operate or service this product unless you have read and understand the General Safety Recommendations, Warning Labels, contained in this manual. Failure to do so may result in bodily injury, or property damage.
Read, study and understand the installation and operating instructions contained in, or referenced in this manual before operating. If you do not understand the instruction, ask a qualified technician. Failure to do so may result in bodily injury, or property damage and will nullify all warranties.
Notice: This manual and the owner’s manual must be given to and retained by the purchasing facility or end user.
Disconnect all power to the junction box prior to making any electrical connections. Failure to do so may result in seriouc personal or fatal injury. When uncertain whether power supply is disconnected, always verify using a voltmeter.
Notice: Wiring must meet all local, state, federal or other governing agency codes.
Notice: All electrical troublshooting or service must be performed by qualified electrical technicians and must comply with all applicable governing agency codes.
Do not place finger or uninsulated tools inside the electrical controller. Touching wires or other parts inside the enclosure may cause electrical shock, serious injury or death.
The Ground wire from the Magnum IV Control 120 VAC Harness, and the Incoming 120 VAC Ground wire must be connected to the Ground screw located within the Swing door Header.
If the door appears broken or does not seem to work correctly, it should be immediately removed from service until repairs can be carried out or a qualified service technician is contacted for corrective action.
Note: All Adjustments must be made with a small screwdriver. Do Not use a pencil.
Note: Do Not take shortcuts.
WARNINGWARNING
WARNING
DANGER
DANGER
CAUTION
CAUTION
Rev. 1-10-14 Part #15-10596-30www.NabcoEntrances.com� Electrical�Installation�Manual�U-30�Control
Scope� 1-5
CHAPTER 1: SCOPE
Section 1a: To the Installer
The purpose of this manual is to familiarize the installer and purchaser with the proper installation and operation of this system. It is essential that this equipment be properly installed and operational before the door is used by the public. It is the installer’s responsibility to inspect the operation of the entrance system to be sure it complies with any applicable standards.
Instruct the building owners and operator on the essentials of the operation of the U30 Microprocessor Controller. The owner should follow these instructions to determine whether the door is operating properly and should immediately call for service if there is any malfunction. All installation changes and adjustments must be made by qualified, NABCO trained technicians.
Section 1b: Objective
The U30 Microprocessor Controller is designed to be installed within the Header of the GT-1175 Slide Door systems.
This manual offers step by step instructions.
Electrical�Installation�Manual�U-30�Control� www.NabcoEntrances.comPart #15-10596-30 Rev. 1-10-14
2-6� Getting�Started
CHAPTER 2: GETTING STARTED
Section 2a: About the U30 Microprocessor Control
The U30 Microprocessor Control is utilized on all GT-1175 Slide Door systems to control numerous operating characteristics that include (but not limited to): speed, recycling sensitivity and reduced opening width.
Note: The U30 Microprocessor Control will need to be programmed after installation is complete.
The U30 Microprocessor Control is also utilized to output power to accessories and/or auxiliary equipment such as:
►► Sensors
►► ModulesThere are times when the U30 Microprocessor Control is not utilized to output power because some accessories and/or auxiliary equipment are shipped with it’s own dedicated power supply.
Section 2b: Electrical Specifications
All Wiring Diagrams included within this manual, reflect typical primary and secondary circuits that are installed at the NABCO Factory. The low voltage Reed Switch (12 VDC) and Sensor(s) are also installed complete with connector housings at the NABCO Factory.
Note: NABCO factory utilizes Underwriters Laboratories (UL) recognized component wire, terminals and connector housings to manufacture GT-1175 Slide Door systems.
Table 2-1 Sensors
Sensor Part Number Function Power Source Current ConsumptionAcusensor 3 14-8902-3 Infrared 12 to 24 AC or DC 100mA
(ea.unit) at 12VDCWizard G3 14-13316 Infrared + Microwave 12 to 24 VAC or VDC 250mAOptex i-one 14-13036 Infrared 12 to 24 VAC or 12 to 30 VDC 130mA
Table 2-2 Modules
Module Part Number Function Power Source Current ConsumptionOptex Beam 14-9710-01 Beam & Control 12 to 24 AC or DC 160mA
(ea.unit) at 12VDCCP/RX Radio Control Receiver
24-11467 RF Signal Transmission 12 to 24 AC or DC 50mA
Rev. 1-10-14 Part #15-10596-30www.NabcoEntrances.com� Electrical�Installation�Manual�U-30�Control
Getting�Started� 2-7
Section 2c: Output Power Guidelines
TOTAL current draw from the U30 Microprocessor Control must not exceed 350 mA (0.35 amps) when outputting power to:
►► Sensors
►► Modules
►► Accessories
►► Auxiliary Equipment
If TOTAL current draw exceeds 350mA (0.35 amps) the installer must utilize an auxiliary power supply such as a 24 VAC Transformer (P/N 14-2101).
The U30 Microprocessor Control and/or the NABCO Power Supply Module Must Not be used to output power to Magnetic Locks or Electric Strikes.
To determine if an auxiliary power supply must be used, add together each current draw for each device. Please refer to the formula shown below:
Example: A GT-1175 Slide Door is to be fitted with the following devices:
2 x Optex i-one Sensors @ 130 mA = 260 mA1 x Optex Beam Module @ 160 mA = 160 mA
Total = 420 mA
420mA exceeds 350mA. An Auxiliary Power Supply must be used to supply power to the Optex Beam Module.
Section 2d: Header Layout
Nabco GT-1175 Sliding Door systems come in many sizes and configurations. Because of this components within the Header are layed out in (1 of 3) different configurations to ensure proper operation of the Drive Belt. Please see configuration details listed below:
►► Operator/Control/Power• Header Width is not wide. Operator needs to be installed to the left of the U30
Microprocessor Control. Please see Figure 2-1.
►► Power/Operator/Control• Header Width is wide, but Operator still needs to be installed between the Power Supply
and the U30 Microprocessor Control. Please see Figure 2-2.
►► Power/Control/Operator• Header Width is wider. Operator can be installed to the right of the Power Supply and
the U30 Microprocessor Control. Please see Figure 2-3.
Note: The Power Supply must never be installed between the U30 Microprocessor Control and the Operator.Note: No matter the location, electrical wiring for all (3) components stays the same.
CAUTION
Electrical�Installation�Manual�U-30�Control� www.NabcoEntrances.comPart #15-10596-30 Rev. 1-10-14
2-8� Getting�Started
Figure 2-1 Header Layout “OCP” with or without Electric LockDN 0537 Power Supply
U30 Microprocessor Controller
Operator
Header
>POM<
071
23
4
5 6 7
89
10
1112
GYRO TECH
DS-150NA(24-11327)
MADE IN JAPAN
1213141516
Sequential Activation SQ
Auxiliary Output (Open-Collector) OUT5Amax.(0-20V), 3.2Amax.(20-30V)30V(42.4Vpeak)max.Contact Output (Class2 Load only)
CommonN/CN/O OUT.A
OUT.BOUT.C
12VDC-(Common) 7
FUNCTION [SLIDING DOOR] SYMBOL No.
Reduced Opening Switch
1110987654321
Breakout DetectorSidelite Presence Sensor
Exterior Activation
BA
62
SLS
M1
HM0
Holding BeamInterior Activation12VDC-(Common)12VDC+
6B
9DC12V761
Mode Switch (see Mode SW Usage shown left)
HANDY TERMINAL・6P
RELA
TED
DEVIC
ES・1
6P
To protect against risk of fire or electric shock,use only the certified NABCO power supply.
WARNING No.MOTOR・12P
ERROR
POWER
BA
62
H
6B
61
INDI
CATO
RSPO
WER・
2P Do not disassem£le the control £ox.There are no user servicea£le parts inside.
To maintain warranty,repairs must £e made £y authori£ed NABCO facilities.
CAUTIONAd£ustments to the door can only £e madewith the NABCO Handy Terminal.
Mode SW Usage
GndGndGnd
Open
OpenOpen
GndOpen
M0 M1 MODETWO WAYONE WAY
NIGHTHOLD OPEN
GYRO TECH
248901- Microprocessor Controller
20VA
C 50
/60H£
TRA
NS
FOR
ME
R
LA
BE
L
AMP
5I
O
TB1
NOISEFILTER
TB2
T1
S1
£NR2£NR1
DN 0536Power Supply U30 Microprocessor Controller
OperatorHeader
TRA
NS
FOR
ME
R
LA
BE
L
AMP
5I
O
TB1
NOISEFILTER
TB2
T1
S1
ZNR2ZNR1
>POM<
071
23
4
5 6 7
89
10
1112
GYRO TECH
DS-150NA(24-11327)
MADE IN JAPAN
1213141516
Sequential Activation SQ
Auxiliary Output (Open-Collector) OUT5Amax.(0-20V), 3.2Amax.(20-30V)30V(42.4Vpeak)max.Contact Output (Class2 Load only)
CommonN/CN/O OUT.A
OUT.BOUT.C
12VDC-(Common) 7
FUNCTION [SLIDING DOOR] SYMBOL No.
Reduced Opening Switch
1110987654321
Breakout DetectorSidelite Presence Sensor
Exterior Activation
BA
62
SLS
M1
HM0
Holding BeamInterior Activation12VDC-(Common)12VDC¡
6B
9DC12V761
Mode Switch (see Mode S¡ Usage shown le¡t)
HANDY TERMINAL・6P
RELA
TED
DEVIC
ES・1
6P
To protect against risk o¡ ¡ire or electric shock,use only the certi¡ied NABCO power supply.
¡A RNING No.MOTOR・12P
ERROR
PO¡E R
BA
62
H
6B
61
INDI
CATO
RSPO
¡ER・
2P Do not disassem¡le the control ¡ox.There are no user servicea¡le parts inside.
To maintain warranty,repairs must ¡e made ¡y authori¡ed NABCO ¡acilities.
CAUTIONAd¡ustments to the door can only ¡e madewith the NABCO Handy Terminal.
Mode S¡ Usag e
GndGndGnd
Open
OpenOpen
GndOpen
M0 M1 MODET¡O ¡A YONE ¡AY
NIGHTHOLD OPEN
GYRO TECH
248901- Microprocessor Controller
20VA
C 50
/60H¡
TRA
NS
FOR
ME
R
LA
BEL
AMP
5I
O
TB1
NOISEFILTER
TB2
T1
S1
ZNR2ZNR1
1213141516
Sequential Activation SQ
Auxiliary Output (Open-Collector) OUT5Amax.(0-20V), 3.2Amax.(20-30V)30V(42.4Vpeak)max.Contact Output (Class2 Load only)
CommonN/CN/O OUT.A
OUT.BOUT.C
12VDC-(Common) 7
FUNCTION [SLIDING DOOR] SYMBOL No.
Reduced Opening Switch
1110987654321
Breakout DetectorSidelite Presence Senso r
Exterior Activation
BA
62
SLS
M1
HM0
Holding BeamInterior Activation12VDC-(Common)12VDC+
6B
9DC12V761
Mode Switch (see Mode SW Usage shown left)
HANDY TERMINAL・6P
RELA
TED
DEVIC
ES・1
6P
To protect against risk of fire or electric shock,use only the certified NABCO power supply.
WARNING No.MOTOR・12P
ERROR
POWER
BA
62
H
6B
61
INDI
CATO
RSPO
WER ・
2P Do not disassemble the control box.There are no user serviceable parts inside.
To maintain warranty,repairs must be made by authorized NABCO facilities.
CAUTIONAdjustments to the door can only be madewith the NABCO Handy Terminal.
Mode SW Usage
GndGndGnd
Open
OpenOpen
GndOpen
M0 M1 MODETWO WAYONE WAY
NIGHTHOLD OPEN
GYRO TECH
248901- Microprocessor Controller
20VA
C 50
/60Hz
>POM¥
071
23
4
5 6 7
89
10
1112
GYRO TECH
DS-150NA(24-11327)
MADE IN ¥APAN
NABCO
DN 0535
Power Supply U30 Microprocessor Controller
OperatorHeader
Figure 2-2 Header Layout “POC” with or without Electric Lock
Figure 2-3 Header Layout “PCO” with or without Electric Lock
Rev. 1-10-14 Part #15-10596-30www.NabcoEntrances.com� Electrical�Installation�Manual�U-30�Control
Connect�Incoming�120�VAC�Wires� 3-9
CHAPTER 3: CONNECT INCOMING 120 VAC WIRES
Disconnect power to the junction box prior to making any electrical connections. Failure to do so may result in serious personal or fatal injury. When uncertain whether power supply is disconnected, always verify using a voltmeter.
Notice: Wiring must meet all local, state, federal or other governing agency codes.
1.►Ensure all power is disconnected at the Junction box.
2.►Ensure all power to the GT-1175 Slide Door is Off.
3.►Inspect the location and grade of all Incoming 120 VAC power cables.
4.►Insert all Incoming 120 VAC, single phase, 5 amp (minimum) power wires into the pre drilled Electric Service Access Hole located at the left or right side of Jamb Tube and Header End Cap.
a. It is recommended for the Installer to house all Incoming 120 VAC wires within an Electrical Conduit.
Keep all Incoming 120 VAC wiring separate from low voltage wiring within Header.
Do Not route 120 VAC wires near the U30 Microprocessor Controller and Operater.
5.►Please see Figure 3-1, to follow steps on how to connect Incoming 120 VAC wires to Power Supply.
6.►Go to the TB1 Port located on the Left side of the Power Supply Module.
7.►Insert the Incoming 120 VAC Black (HOT) wire into the Circuit marked “L”.
8.►Insert the Incoming 120 VAC White (Neutral) wire into the Circuit marked “N”.
9.►Insert Green (Grounding) wire into the Circuit marked “PE”.
Read and understand the “U30 Controller Setup and Programming Manual” P/N 15-9000 before attempting to power-up the GT-1175 Slide Door. Failure to do so may result in damage to the Slide door and/or injury to the installer and will nullify all warranties.
Figure 3-1 Connect Incoming 120 VAC Wires to Power SupplyDN 0538Grounding Wire
P/N 14-11872
White Wire(Common)
Black Wire (Hot)
ON/OFFPower Switch
TB1
NOISEFILTER
TB2
T1
S1
PEN
L
LOA
D
-CIRCUIT- -BREAKER-
RED INDICATESPOWER IS OFF
PRESSTO
RESET
POWER SUPPLYASSEMBLY
P/N 9418800100NABCO
14-11741ENTRANCES, INC.
0712
34
5 6 7
89
10
1112
>POM<
NABCO
GYRO TECH
DS-1500 D24-113270
Nabtesco CorporationMADE IN JAPAN
NABCO
NABCO
CAUTION!
RELA
TED
DEVIC
ES・1
6P
1213141516
No .
1110987654321
SYMBOL
HM0
9DC12V
SQ
OU TCommonN/CN/O OUT. A
OUT. BOUT. C
7
BA
62
SLS
M1
6B
761
A
Auxiliary Output (Open-Collector)5Amax.(0-20V), 3.2Amax.(20-30V)30V(42.4Vpeak)maxContact Output (Class2 Load only)
12VDC-(Common)
FUNCTION (SLIDING DOOR)
Reduced Opening Switch
Breakout DetectorSidelite Presence Sensor
Exterior
Holding BeamInterior n12VDC-(Common)12VDC +
HANDY TERMINAL 6PNo.
248901- Microprocessor Controller
Mode SW Usage
Gn dGn dGn d
Open
OpenOpen
Gn dOpen
M0 M1 MODETWO WAYONE WAY
NIGH THOLD OPEN
To protect against risk of Fire or electric shock,use only the MOTOR 12P
ERROR
POWER
BA
62
H
6B
61
INDICA
TORS
POWE
R2P
Do not disassemble the control box.There are no user serviceable parts inside.
To maintain warranty,repairs must be made by authorized NABCO facilities.
Adjustments to the door can only be madewith the NABCO Handy Terminal.
20VA
C 50/6
0Hz
GYRO TECHNABCO
!!
!
!
WARNING
DANGER
CAUTION
CAUTION
DANGER
Electrical�Installation�Manual�U-30�Control� www.NabcoEntrances.comPart #15-10596-30 Rev. 1-10-14
4-10� Identify�Operating�Wires
CHAPTER 4: IDENTIFY OPERATING WIRES
Section 4a: 16 Pin Controller Terminal Block Assignments
Note: All wires are identified by color. All references to signals are made in connection with Common (Red).
Note: Use a flat-blade screwdriver to remove the Terminal Connector from the U30 Microprocessor Controller. Ensure that all wires are matched to each appropriate Terminal. Each Terminal is numbered with corresponding information on the Face Plate of the U30 Microprocessor Controller.
Note: Common Terminal indicates terminal can be Output or Input.
* Color1/Color2 denotes a base wiring Color 1 with a stripe Color 2. For example: Black/Red indicates a Black wire with a Red Stripe.
Terminal # Symbol Color Description1 9DC12V Brown X Output terminal
• Sensor power source. • Output is 12VDC with a maximum capacity of 350mA (.35 amp).
2 7 Red X Common terminal • Provides common ground for the 12 VDC power and signal source.
3 61 Black X Input terminal • Interior Activation signal.• Opens the door in two-way and one-way modes only.
4 6B White X Input terminal • Holding Beam signal.• Opens or re-opens a Sliding door.
5 H Green X Input terminal• Reduced Opening Switch signal.• Reduces Slide door opening when switched to Red (7).
6 M0 Orange X Input terminal• Mode Switch One (SW1).• Used to acheive special functions. Please refer to “Switch Settings”
section within this chapter.7 M1 Orange/
White* X Input terminal
• Mode Switch Two (SW2).• Used to acheive special functions. Please refer to “Switch Settings”
section within this chapter.8 62 Black/
Red* X Input terminal
• Exterior Activation signal.• Opens the door in two-way mode only.
9 SQ Yellow X Input terminal• Sequential Activation signal.• Allows a sequence of signals to open and close Slide door.
Rev. 1-10-14 Part #15-10596-30www.NabcoEntrances.com� Electrical�Installation�Manual�U-30�Control
Identify�Operating�Wires� 4-11
Terminal # Symbol Color Description10 BA Blue X Input terminal
• Breakout Detector signal.• Connected to Red (7) during normal operation.• Disconnected from Red (7) during ‘stop door’ operation. Will
happen if:• Switch is turned OFF• Slide door is panicked open
11 SLS Green/White*
X Input terminal• Sidelite Presence Sensor.• At fully closed position, input will prevent Slide door from opening.
12 OUT A Gray X Auxiliary Output terminal• Connected to Normally Open contact on an internal relay. • Referred to as ‘Auxiliary Relay Output” throughout manual.• Used as a Switch to:
• Sequence an Electric Strike.• Control other Slide doors in an air lock situation.• Signal a remote computer on the Slide door operation.
13 OUT B Gray X Auxiliary Output terminal• Connected to Normally Closed contact on an internal relay.
14 OUT C Violet X Auxiliary Output terminal• Common for output wire “OUT A” or ‘OUT B”
15 OUT Brown/Yellow*
X Auxiliary Output 2 terminal• Connected to an Internal Transistor with Open Collector in the U30
Microprocessor Controller.• Installer must provide wire for this terminal (not normally utilized).
16 7 Red X Common terminal• Provides common ground for the 12 VDC power and signal source.
Section 4b: Sensor Wire Connections
* Color1/Color2 denotes a base wiring Color 1 with a stripe Color 2. For example: Black/Red indicates a Black wire with a Red Stripe.
** Denotes wiring that has been crimped together at NABCO factory.
Table 4-1 Acusensor
U30 Harness Extension Harness Acusensor HarnessRed Common Red **White and Red
Black Signal, InteriorYellow Green
*Black/Red Signal ExteriorBrown +12 VDC Gray Black
Electrical�Installation�Manual�U-30�Control� www.NabcoEntrances.comPart #15-10596-30 Rev. 1-10-14
4-12� Identify�Operating�Wires
Table 4-2 Optex i-one
U30 Harness Extension Harness Optex i-one HarnessRed Common Red **Gray and White
Black Interior SignalYellow Yellow
*Black/Red Exterior SignalBrown +12 VDC Gray Gray
Table 4-3 Wizard
U30 Harness Extension Harness Wizard HarnessRed Common Red **Red and White and Brown
Black Interior SignalYellow Green and Blue
*Black/Red Exterior SignalBrown +12 VDC Gray Black
Section 4c: Rocker Switch SettingsOFF = Not switched to COMMON ON = Switched to COMMON (RED 7)
Rocker Switch Mode
Key Switch Mode
Wire M0
Wire M1
Wire H Description
Night Night OFF ON - X Sensors on Terminal (3) and (8) can not open the door while door is closed.
X Sensors on Terminal (3) and (8) will provide threshold safety when door is in any position other than closed.
X Electric Lock remains locked unless an activation signal is given from a device (such as card reader, key switch, wall plate, etc.): connected in one of two ways:1.►Between Common and MO (7)
a.►This only works when door is in “Night” mode2.►Between Common and SLS (11)
a.►This only works if the SLS is programmed for activation devices.
Note: Consult the U30 Programming Manual for details; (P/N 15-9000-30).
Hold Open H.O. ON ON - X No activation needed when “Hold Open” is selected. Slide door is held open.
X Electric Lock is always unlocked.Two Way Auto OFF OFF - X Sensors on Terminal (3) and (8) can both open
the door. X Electric Lock is always unlocked.
Rev. 1-10-14 Part #15-10596-30www.NabcoEntrances.com� Electrical�Installation�Manual�U-30�Control
Identify�Operating�Wires� 4-13
Rocker Switch Mode
Key Switch Mode
Wire M0
Wire M1
Wire H Description
One Way Exit ON OFF - X Sensor on Terminal (3) can open the door. • Sensor is normally Interior and used to activate door
for one-way traffic. X Sensor on Terminal (8) can not open the door from the
closed position.• Sensor is normally Exterior and used to provide
threshold safety only. • Electric Lock remains locked unless an activation
occurs from the interior sensor or by a device (such as a card reader, key switch, wall plate, etc.) that is connected in one of two ways:
1.►Between Common and M1 (6)a.►This only works when door is in “One Way” or
“Exit” mode.2.►Between Common and SLS (11)
a.►This only works if the SLS is programmed for activation devices.
Note: Consult the U30 Programming Manual for details; (P/N 15-9000-30).
Full Open Full - - OFF X Upon activation or in Hold Open mode, Slide door will open to the full position.
Reduced Open Reduced - - ON X Upon activation, Slide door will open to the Reduced Open position.
Electrical�Installation�Manual�U-30�Control� www.NabcoEntrances.comPart #15-10596-30 Rev. 1-10-14
5-14� Wiring�Diagrams�(Surface�Applied�Sliders)
CHAPTER 5: WIRING DIAGRAMS
Section 5a: (2) Acusensors and (1) Holding Beam
MO
TOR/
OPE
RATO
RP/
N 2
4-11
327
Pow
er H
arne
ss
P/N
14-
1187
4Gr
ound
ing
Wire
P/
N 1
4-11
872
U30
MIC
ROPR
OCE
SSO
R CO
NTR
OL
P/N
24-
8901
-30
12VD
C Co
mm
on
12 V
DC+
12VD
C- (C
omm
on)
Hold
ing
Beam
Redu
ced
Ope
ning
Sw
itch
Mod
e Sw
itch
Brea
kout
Det
ecto
rSi
delit
e Pr
esen
ce S
enso
rCo
ntac
t Out
put (
Clas
s2 L
oad
only
)
30V
(42.
4V p
eak)
max
.5A
max
, (0-
20V)
, 3.2
A m
ax. (
20-3
0V)
Auxi
liary
Out
put (
Ope
n Co
llect
or)
N/O
N/C
Com
mon
9DC
12V
7
61
6B
H
M
0
M1
62
SQ
BA
SL
S
O
ut.A
Out
.B
O
ut.C
Out
7
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
Related Devices - 16P
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
Whi
te W
ire(C
omm
on)
Blac
k W
ire (H
ot)
RED
BRO
WN
RED
BLAC
KW
HITE
GREE
NO
RAN
GEO
RG/W
HTBL
K/RE
DBL
K/RE
D
GRN
/WHT
YELL
OW
DN 0
539
MAI
N H
ARN
ESS
FOR
U30
P/
N 2
4-11
877
BRO
WN
&RE
D (C
IRCU
IT 1
& 2
)
EX
TER
IOR
AC
US
EN
SO
RP
T. N
O. 1
4-89
02
PT.
NO
. 14-
8902
INTE
RIO
R A
CU
SE
NS
OR
ON
OFF
NIG
HT
TWO WAY
ON
E W
AY
HO
LD O
PE
N
FULLOPEN
RE
DU
CE
D O
PE
N
BLU
E
KEY
SWIT
CH
FOR
U30
PN
14-
1187
6
ROCK
ER S
WIT
CH
FOR
U30
PN
14-
1187
5
BACK
SID
E O
F RO
CKER
SW
ITCH
SHO
WN
ACU
SEN
SOR
EXTE
NSI
ON
HA
RNES
S PN
22-
9267
-00
ACU
SEN
SOR
EXTE
NSI
ON
HA
RNES
S PN
22-
9267
-00
OPT
EX
HOLD
ING
BEAM
CO
NTR
OLL
ER
PT. N
O.
PN 1
4-97
10-0
3TERM
#1
RED
BRO
WN
RED
BRO
WNBL
K RED
GRAY
YELL
OW
YELL
OW
GRAY
RED
RED
BLU
E
RED
ORA
NGE
ORG
/WHT
ORG
/WHT
RED
GREE
N
RED
ORA
NGE
RED
ORG
/WHT
BLU
EGR
EEN
ORA
NGE
Opt
ex O
S-1
2CC
ontro
ller
POW
ER S
UPP
LY
P/N
14-
1174
1
AC11
5V ±
10%
50
/ 60
Hz
Auxi
liary
120
VAC
Po
wer
Wire
s (T
hese
wire
s are
nor
mal
ly
ON
/OFF
Po
wer
Sw
itch
BLU
E
U30
TER
MIN
ALU
30 M
ICRO
PRO
CESS
OR
CON
TRO
L LA
BEL
WHI
TETE
RM #
5
RED
TERM
#4
BLU
E
BLU
E
WHI
TEW
HITE
WHI
TEW
HITE
MAG
NET
IC P
OW
ER
DOW
NSW
ITCH
P/
N 2
2-92
22
WHI
TEW
HITE
BLU
E
TB1
NO
ISE
FILT
ER
TB2
T1
S1
PENL
LOAD
-CIR
CUIT
- -B
REA
KER-
RED
IND
ICAT
ESPO
WER
IS O
FF
PRES
STO
RE
SET
POW
ER S
UPP
LYA
SSEM
BLY
P/N
941
8800
100
NA
BCO
14-1
1741
ENTR
AN
CES,
INC.
071
2 3 4 56
7
8910
1112
>POM<
NA
BC
O
GYR
O T
ECH
DS
-150
0 D
24-1
1327
0
Nab
tesc
o C
orpo
ratio
nMA
DE IN
JAPA
N
NA
BCO
NA
BCO
CAUTION
!
RELATED DEVICES・16P
12 13 14 15 16No.
1110987654321SY
MBOL
H M09DC1
2V
SQ OUT
Comm
onN/
CN/
OOU
T. A
OUT.
BOU
T. C
7BA62 SLSM1
6B7 61
Sequ
en�a
l Ac
�va�
on
Auxil
iary O
utpu
t (Op
en-C
ollec
tor)
5Am
ax.(0
-20V
), 3.2A
max
.(20-
30V )
30V(
42.4V
peak
)max
Cont
act O
utpu
t (Cla
ss2 Lo
ad on
ly)
12VD
C-(Co
mmon
)FUNC
TION
(SLID
ING
DOOR
)
Redu
ced O
penin
g Swi
tch
Brea
kout
Detec
torSid
elite
Pres
ence
Sens
or
Exte
rior A
c�va
�on
Holdi
ng Be
amIn
terio
r Ac�
va�o
n12
VDC-(
Comm
on)
12VD
C+
Mod
e Swi
tch (s
ee M
ode S
W U
sage
show
n le�
)
HAND
YTE
RMIN
AL6P
No.
2489
01-
Micr
opro
cess
or C
ontro
ller
Mode
SW Us
age
Gnd
Gnd
Gnd
Open
Open
Open
Gnd
OpenM0
M1
MODE
TWO
WAY
ONE
WAY
NIGH
THO
LD O
PEN
To p
rote
ct ag
ainst
risk o
f Fire
or
elec
tric s
hock
,use
onl
y the
ce
r�fie
d NA
BCO
powe
r sup
ply.
WARNING
MOT
OR 12
P
ERRO
R
POWER
BA62H6B61
INDICATORS POWER2P
Do n
ot d
isass
emble
the
cont
rol b
ox.
Ther
e ar
e no
use
r ser
vicea
ble
parts
in
side.
To m
aint
ain
warra
nty,r
epai
rs m
ust b
e m
ade
by a
utho
rized
NAB
CO fa
cilitie
s.
Adjus
tmen
ts to
the
door
can
only
be m
ade
with
the
NABC
O Ha
ndy T
erm
inal.
20VAC 50/60Hz
GYR
O T
ECH
NAB
CO!!
! !
U30
TER
MIN
ALP/
N 2
4-11
877
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
Rev. 1-10-14 Part #15-10596-30www.NabcoEntrances.com� Electrical�Installation�Manual�U-30�Control
Wiring�Diagrams�(Surface�Applied�Sliders)� 5-15
Section 5b: (2) Optex i-One Sensors and (1) Holding Beam
Pow
er H
arne
ss
P/N
14-
1187
4Gr
ound
ing
Wire
P/
N 1
4-11
872
12VD
C Co
mm
on
12 V
DC+
12VD
C- (C
omm
on)
Hold
ing
Beam
Redu
ced
Ope
ning
Sw
itch
Mod
e Sw
itch
Brea
kout
Det
ecto
rSi
delit
e Pr
esen
ce S
enso
rCo
ntac
t Out
put (
Clas
s2 L
oad
only
)
30V
(42.
4V p
eak)
max
.5A
max
, (0-
20V)
, 3.2
A m
ax. (
20-3
0V)
Auxi
liary
Out
put (
Ope
n Co
llect
or)
N/O
N/C
Com
mon
9DC
12V
7
61
6B
H
M
0
M1
62
SQ
BA
SL
S
O
ut.A
Out
.B
O
ut.C
Out
7
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
Related Devices - 16P
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
Whi
te W
ire(C
omm
on)
Blac
k W
ire (H
ot)
RED
BRO
WN
RED
BLAC
KW
HITE
GREE
NO
RAN
GEO
RG/W
HTBL
K/RE
DBL
K/RE
D
GRN
/WHT
YELL
OW
DN 0
685
MAI
N H
ARN
ESS
FOR
U30
P/
N 2
4-11
877
EX
TER
IOR
OP
TEX
I-1
PT.
NO
. 14-
1303
6P
T. N
O. 1
4-13
036
INTE
RIO
R O
PTE
X I-
1
ON
OFF
NIG
HT
TWO WAY
ON
E W
AY
HO
LD O
PE
N
FULLOPEN
RE
DU
CE
D O
PE
N
KEY
SWIT
CH
FOR
U30
PN
14-
1187
6
ROCK
ER S
WIT
CH
FOR
U30
PN
14-
1187
5
BACK
SID
E O
F RO
CKER
SW
ITCH
SHO
WN
OPT
EXHA
RNES
SP/
N 1
2-13
018
ACU
SEN
SOR
EXTE
NSI
ON
HARN
ESS
PN 2
2-92
67-0
0
RED GR
AY
YELL
OW
RED
BLU
E
RED
ORA
NGE
ORG
/WHT
ORG
/WHT
RED
GREE
N
RED
ORA
NGE
RED
ORG
/WHT
BLU
EGR
EEN
ORA
NGE
AC11
5V ±
10%
50
/ 60
Hz
Auxi
liary
120
VAC
Po
wer
Wire
s (T
hese
wire
s are
nor
mal
ly
ON
/OFF
Po
wer
Sw
itch
BLU
E
U30
TER
MIN
ALU
30 M
ICRO
PRO
CESS
OR
CON
TRO
L LA
BEL
BRO
WN
&RE
D (C
IRCU
IT 1
& 2
)
OPT
EX
HOLD
ING
BEAM
CO
NTR
OLL
ER
PT. N
O.
PN 1
4-97
10-0
3TERM
#1
Opt
ex O
S-1
2CC
ontro
ller
WHI
TETE
RM #
5
RED
TERM
#4
WHI
TE
GRAY
BLK
GRAY
YELL
OW
BRO
WN
RED GR
AY
YELL
OW
WHI
TE
GRAY
BLK
GRAY
RED
YELL
OW
BRO
WN
ACU
SEN
SOR
EXTE
NSI
ON
HARN
ESS
PN 2
2-92
67-0
0
BLU
E
BLU
E
BLU
E
WHI
TEW
HITE
WHI
TEW
HITE
MAG
NET
IC P
OW
ER
DOW
NSW
ITCH
P/
N 2
2-92
22
WHI
TEW
HITE
BLU
E
MO
TOR/
OPE
RATO
RP/
N 2
4-11
327
U30
MIC
ROPR
OCE
SSO
R CO
NTR
OL
P/N
24-
8901
-30
POW
ER S
UPP
LY
P/N
14-
1174
1
U30
TER
MIN
ALP/
N 2
4-11
877
TB1
NO
ISE
FILT
ER
TB2
T1
S1
PENL
LOAD
-CIR
CUIT
- -B
REA
KER-
RED
IND
ICAT
ESPO
WER
IS O
FF
PRES
STO
RE
SET
POW
ER S
UPP
LYA
SSEM
BLY
P/N
941
8800
100
NA
BCO
14-1
1741
ENTR
AN
CES,
INC.
071
2 3 4 56
7
8910
1112
>POM<
NA
BC
O
GYR
O T
ECH
DS
-150
0 D
24-1
1327
0
Nab
tesc
o C
orpo
ratio
nMA
DE IN
JAPA
N
NA
BCO
NA
BCO
CAUTION
!
RELATED DEVICES・16P
12 13 14 15 16No.
1110987654321SY
MBOL
H M09DC1
2V
SQ OUT
Comm
onN/
CN/
OOU
T. A
OUT.
BOU
T. C
7BA62 SLSM1
6B7 61
Sequ
en�a
l Ac
�va�
on
Auxil
iary O
utpu
t (Op
en-C
ollec
tor)
5Am
ax.(0
-20V
), 3.2A
max
.(20-
30V )
30V(
42.4V
peak
)max
Cont
act O
utpu
t (Cla
ss2 Lo
ad on
ly)
12VD
C-(Co
mmon
)FUNC
TION
(SLID
ING
DOOR
)
Redu
ced O
penin
g Swi
tch
Brea
kout
Detec
torSid
elite
Pres
ence
Sens
or
Exte
rior A
c�va
�on
Holdi
ng Be
amIn
terio
r Ac�
va�o
n12
VDC-(
Comm
on)
12VD
C+
Mod
e Swi
tch (s
ee M
ode S
W U
sage
show
n le�
)
HAND
YTE
RMIN
AL6P
No.
2489
01-
Micr
opro
cess
or C
ontro
ller
Mode
SW Us
age
Gnd
Gnd
Gnd
Open
Open
Open
Gnd
OpenM0
M1
MODE
TWO
WAY
ONE
WAY
NIGH
THO
LD O
PEN
To p
rote
ct ag
ainst
risk o
f Fire
or
elec
tric s
hock
,use
onl
y the
ce
r�fie
d NA
BCO
powe
r sup
ply.
WARNING
MOT
OR 12
P
ERRO
R
POWER
BA62H6B61
INDICATORS POWER2P
Do n
ot d
isass
emble
the
cont
rol b
ox.
Ther
e ar
e no
use
r ser
vicea
ble
parts
in
side.
To m
aint
ain
warra
nty,r
epai
rs m
ust b
e m
ade
by a
utho
rized
NAB
CO fa
cilitie
s.
Adjus
tmen
ts to
the
door
can
only
be m
ade
with
the
NABC
O Ha
ndy T
erm
inal.
20VAC 50/60Hz
GYR
O T
ECH
NAB
CO!!
! !
RED
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
Electrical�Installation�Manual�U-30�Control� www.NabcoEntrances.comPart #15-10596-30 Rev. 1-10-14
5-16� Wiring�Diagrams�(Surface�Applied�Sliders)
Section 5c: (2) Acusensors, (1) Holding Beam and (1) Breakout Beam
TB1
NO
ISE
FILT
ER
TB2
T1
S1
PENL
LOAD
-CIR
CUIT
- -B
REA
KER-
RED
IND
ICAT
ESPO
WER
IS O
FF
PRES
STO
RE
SET
POW
ER S
UPP
LYA
SSEM
BLY
P/N
941
8800
100
NA
BCO
14-1
1741
ENTR
AN
CES,
INC
.
071
2 3 4 56
7
8910
1112
>POM<
NA
BC
O
GY
RO
TEC
H
DS-
1500
D
24-1
1327
0
Nab
tesc
o C
orpo
ratio
nMA
DEIN
JAPA
N
NA
BC
O
NA
BCO
MO
TOR/
OPE
RATO
RP/
N 2
4-11
327
Pow
er H
arne
ss (P
/N 1
4-11
874)
Grou
ndin
g W
ireP/
N 1
4-11
872
U30
MIC
ROPR
OCE
SSO
R CO
NTR
OLL
ERP/
N 2
4-89
01-3
0
12VD
C Co
mm
on
12 V
DC+
12VD
C- (C
omm
on)
Inte
rior A
c� v
a� o
nHo
ldin
g Be
amRe
duce
d O
peni
ng S
witc
hM
ode
Switc
h (S
ee M
ode
SW U
sage
Sho
wn
Le� )
Exte
rior A
c� v
a� o
nSe
quen
� al A
c� v
a� o
nBr
eako
ut D
etec
tor
Side
lite
Pres
ence
Sen
sor
Cont
act O
utpu
t (Cl
ass2
Loa
d on
ly)
30V
(42.
4V p
eak)
max
.5A
max
, (0-
20V)
, 3.2
A m
ax. (
20-3
0V)
Auxi
liary
Out
put (
Ope
n Co
llect
or)
N/O
N/C
Com
mon
9DC
12V
7
61
6B
H
M
0
M1
62
SQ
BA
SL
S
O
ut.A
Out
.B
O
ut.C
Out
7
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
Related Devices - 16P
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
Whi
te W
ire(C
omm
on)
Blac
k W
ire (H
ot)
RED
BRO
WN
RED
BLAC
KW
HITE
GREE
NO
RAN
GEO
RG/W
HTBL
K/RE
D
WHI
TE
BLK/
RED
GRN
/WHT
YELL
OW
DN 0
541
Mai
n Ha
rnes
s For
U30
P/
N 2
4-11
877
BRO
WN
&RE
D(T
ERM
1 &
2)
ON
OFF
NIG
HT
TWO WAY
ON
E W
AY
HO
LD O
PE
N
FULLOPEN
RE
DU
CE
D O
PE
N
BLU
E
BLU
EBL
UE
WHI
TEW
HITE
WHI
TEW
HITE
KEY
SWIT
CHFO
R U
30P/
N 1
4-11
876
ROCK
ER S
WIT
CHFO
R U
30P/
N 1
4-11
875
BACK
SID
E O
FRO
CKER
SW
ITCH
SHO
WN
ROCK
ER S
WIT
CHEX
TEN
SIO
N H
ARN
ESS
FOR
U30
P/N
14-
1188
4
ACU
SEN
SOR
EXTE
NSI
ON
HARN
ESS
P/N
22-
9267
-00
ACU
SEN
SOR
EXTE
NSI
ON
HARN
ESS
P/N
22-
9267
-00
OPT
EXHO
LDIN
G BE
AMCO
NTR
OLL
ERPT
. NO
.P/
N 1
4-97
10-0
3
TERM
#1
RED
BRO
WN
RED
BRO
WNBL
K RED
GRAY
YELL
OW
YELL
OW
GRAY
RED
RED
BLU
E
RED
ORA
NGE
ORG
/WHT
ORG
/WHT
RED
GREE
N
RED
ORA
NGE
RED
ORG
/WHT
BLU
EGR
EEN
ORA
NGE
20VAC 50/60Hz
Micr
opro
cess
or C
ontro
ller
2489
01-
GY
RO
TE
CH
HOLD
OPE
NNI
GHT
ONE
WAY
TWO
WAY
MODE
M1
M0 Open
Gnd
Open
Open
Open
GndG
nd Gnd
Mode
SW
Usa
ge
Adjus
tmen
ts to
the
door
can
only
be m
ade
with
the
NABC
O Ha
ndy T
erm
inal.
CAUT
ION
To m
aint
ain
warra
nty,r
epai
rs m
ust b
e m
ade
by a
utho
rized
NAB
CO fa
cilitie
s.
Do n
ot d
isass
emble
the
cont
rol b
ox.
Ther
e ar
e no
use
r ser
vicea
ble p
arts
inside
.
POWER・2PINDICATORS
61 6B H 62 BA
POWE
R
ERRO
RMOTO
R・12
PN
o.W
ARNI
NGTo
pro
tect
aga
inst
risk
of
fire
or e
lect
ric s
hock
,use
onl
y th
e ce
rtifie
d NA
BCO
pow
er s
uppl
y.
RELATED DEVICES・16P
HAND
Y TE
RMIN
AL・6
P
Mode
Swi
tch (s
ee M
ode S
W U
sage
show
n left
)
6179DC1
2V
6B
12VD
C+12
VDC-
(Com
mon)
Inte
rior A
ctiva
tion
Holdi
ng B
eam
M0H M1
SLS
62 BA
Exte
rior A
ctiva
tion
Side
lite P
rese
nce S
enso
rBr
eako
ut De
tector
1 2 3 4 5 6 7 8 9 10 11
Redu
ced O
penin
g Swi
tch
No.
SYMB
OLFU
NCTI
ON [S
LIDIN
G DO
OR]
712
VDC-
(Com
mon)
OUT.C
OUT.B
OUT.A
N/O
N/C
Comm
on
Conta
ct Ou
tput (
Clas
s2 Lo
ad on
ly)30
V(42
.4Vpe
ak)m
ax.
5Am
ax.(0
-20V
), 3.
2Am
ax.(2
0-30
V)OU
TAu
xiliar
y Out
put (
Open
-Coll
ecto
r)
SQSe
quen
tial A
ctiva
tion
1615141312
!!
!
! !
NABCO
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
POW
ER S
UPP
LYP/
N 1
4-11
741
AC11
5V ±
10%
50 /
60 H
z
Auxi
liary
120
VAC
Pow
er W
ires
(The
se w
ires a
re n
orm
ally
coile
d an
d � e
d up
)
ON
/OFF
Pow
er S
witc
h
BLU
E
MAG
NET
IC P
OW
ER
DOW
N S
WIT
CHP/
N 2
2-92
22
OPT
EXBR
EAKO
UT
BEAM
CON
TRO
LLER
PT. N
O.
P/N
14-
9710
-03
TERM
#1
BRO
WN
&RE
D(T
ERM
1 &
2)
BLU
E(T
ERM
#4)
BLU
E(T
ERM
#3)
WHI
TE(T
ERM
#5)
U30
TER
MIN
ALP/
N 1
4-11
873
U30
TER
MIN
ALU
30 M
ICRO
PRO
CESS
OR
CON
TRO
LLER
LAB
ELRE
D(T
ERM
#4)
HAN
DY T
ERM
INAL
HAR
NES
SP/
N 1
4-11
837
INTE
RIO
R AC
USE
NSO
RP/
N 1
4�89
02EX
TERI
OR
ACU
SEN
SOR
P/N
14�
8902
OPT
EX O
S-12
CCo
ntro
ller
OPT
EX O
S-12
CCo
ntro
ller
Rev. 1-10-14 Part #15-10596-30www.NabcoEntrances.com� Electrical�Installation�Manual�U-30�Control
Wiring�Diagrams�(Surface�Applied�Sliders)� 5-17
Section 5d: (2) Optex i-One Sensors, (1) Holding Beam and (1) Breakout BeamTB
1
NO
ISE
FILT
ER
TB2
T1
S1
PENL
LOAD
-CIR
CUIT
- -B
REA
KER-
RED
IND
ICAT
ESPO
WER
IS O
FF
PRES
STO
RE
SET
POW
ER S
UPP
LYA
SSEM
BLY
P/N
941
8800
100
NA
BCO
14-1
1741
ENTR
AN
CES,
INC
.
071
2 3 4 56
7
8910
1112
>POM<
NA
BC
O
GY
RO
TEC
H
DS
-150
0 D
24-1
1327
0
Nab
tesc
o C
orpo
ratio
nMA
DEIN
JAPA
N
NA
BC
O
NA
BCO
MO
TOR/
OPE
RATO
R P/
N 2
4-11
327
Pow
er H
arne
ss P/
N 1
4-11
874
Grou
ndin
g W
ire
P/N
14-
1187
2
U30
MIC
ROPR
OCE
SSO
R CO
NTR
OLL
ER
P/N
24-
8901
-30
12VD
C Co
mm
on
12 V
DC+
12VD
C- (C
omm
on)
Hold
ing
Beam
Redu
ced
Ope
ning
Sw
itch
Mod
e Sw
itch
Brea
kout
Det
ecto
rSi
delit
e Pr
esen
ce S
enso
rCo
ntac
t Out
put (
Clas
s2 L
oad
only
)
30V
(42.
4V p
eak)
max
.5A
max
, (0-
20V)
, 3.2
A m
ax. (
20-3
0V)
Auxi
liary
Out
put (
Ope
n Co
llect
or)
N/O
N/C
Com
mon
9DC
12V
7
61
6B
H
M
0
M1
62
SQ
BA
SL
S
O
ut.A
Out
.B
O
ut.C
Out
7
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
Related Devices - 16P
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
Whi
te W
ire(C
omm
on)
Blac
k W
ire (H
ot)
RED
BRO
WN
RED
BLAC
KW
HITE
GREE
NO
RAN
GEO
RG/W
HTBL
K/RE
DBL
K/RE
D
GRN
/WHT
YELL
OW
DN 0
542
MAI
N H
ARN
ESS
FOR
U30
P/
N 2
4-11
877
BRO
WN
&RE
D (T
ERM
1 &
2)
ON
OFF
NIG
HT
TWO WAY
ON
E W
AY
HO
LD O
PE
N
FULLOPEN
RE
DU
CE
D O
PE
N
BLU
E
BLU
EBL
UE
WHI
TEW
HITE
WHI
TEW
HITE
KEY
SWIT
CH
FOR
U30
PN
14-
1187
6
ROCK
ER S
WIT
CH
FOR
U30
PN
14-
1187
5
BACK
SID
E O
F RO
CKER
SW
ITCH
SHO
WN
ROCK
ER S
WIT
CH
EXTE
NSI
ON
HAR
NES
S FO
R U
30
PN 1
4-11
884
ACU
SEN
SOR
EXTE
NSI
ON
HA
RNES
S PN
22-
9267
-00
ACU
SEN
SOR
EXTE
NSI
ON
HA
RNES
S PN
22-
9267
-00
OPT
EX
HOLD
ING
BEAM
CO
NTR
OLL
ER
PT. N
O.
PN 1
4-97
10-0
3
TERM
#1
RED
BRO
WN
RED
BRO
WNBL
K RED
GRAY
YELL
OW
YELL
OW
GRAY
RED
RED
BLU
E
RED
ORA
NGE
ORG
/WHT
ORG
/WHT
RED
GREE
N
RED
ORA
NGE
RED
ORG
/WHT
BLU
EGR
EEN
ORA
NGE
Opt
ex O
S-1
2CC
ontro
ller
20VAC 50/60Hz
Micr
opro
cess
or C
ontro
ller
2489
01-
GY
RO
TE
CH
HOLD
OPE
NNI
GHT
ONE
WA Y
TWO
WAY
MODE
M1
M0 Open
Gnd
Open
Open
Open
GndG
nd Gnd
Mode
SW
Usa
ge
Adjus
tmen
ts to
the
door
can
only
be m
ade
with
the
NABC
O Ha
ndy T
erm
inal.
CAUT
ION
To m
aint
ain
warra
nty,r
epai
rs m
ust b
e m
ade
by a
utho
rized
NAB
CO fa
cilitie
s.
Do n
ot d
isass
emble
the
cont
rol b
ox.
Ther
e ar
e no
use
r ser
vicea
ble p
arts
inside
.
POWER・2PINDICATORS
61 6B H 62 BA
POWE
R
ERRO
RMOTO
R・12
PN
o.W
ARNI
NGTo
pro
tect
aga
inst
risk
of
fire
or e
lect
ric s
hock
,use
onl
y th
e ce
rtifie
d NA
BCO
pow
er s
uppl
y.
RELATED DEVICES・16P
HAND
Y TE
RMIN
AL・6
P
Mode
Swi
tch (s
ee M
ode S
W U
sage
show
n left
)
6179DC1
2V
6B
12VD
C+12
VDC-
(Com
mon)
Inte
rior A
ctiva
tion
Holdi
ng B
eam
M0H M1
SLS
62 BA
Exte
rior A
ctiva
tion
Side
lite P
rese
nce S
enso
rBr
eako
ut De
tector
1 2 3 4 5 6 7 8 9 10 11
Redu
ced O
penin
g Swi
tch
No.
SYMB
OLFU
NCTI
ON [S
LIDIN
G DO
OR]
712
VDC-
(Com
mon)
OUT.C
OUT.B
OUT.A
N/O
N/C
Comm
on
Conta
ct Ou
tput (
Clas
s2 Lo
ad on
ly)30
V(42
.4Vpe
ak)m
ax.
5Am
ax.(0
-20V
), 3.
2Am
ax.(2
0-30
V)OU
TAu
xiliar
y Out
put (
Open
-Coll
ecto
r)
SQSe
quen
tial A
ctiva
tion
1615141312
!!
!
! !
NABCO
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
POW
ER S
UPP
LY
P/N
14-
1174
1
AC11
5V ±
10%
50
/ 60
Hz
Auxi
liary
120
VAC
Po
wer
Wire
s (T
hese
wire
s are
ON
/OFF
Po
wer
Sw
itch
MAG
NET
IC P
OW
ER
DOW
N S
WIT
CH
P/N
22-
9222
OPT
EX
HARN
ESS
PN 1
2-13
018
GRAY
YELL
OW
WHI
TE
GRAY
GRAY
GRAY
YELL
OW
WHI
TE
INTE
RIO
R O
PTEX
I-O
NE
PN 1
4-10
364-
AEX
TERI
OR
OPT
EX I-
ON
E PN
14-
1036
4-A
BLU
E
OPT
EX
BREA
KOU
T BE
AM
CON
TRO
LLER
PT
. NO
. PN
14-
9710
-03
TERM
#1
Opt
ex O
S-1
2CC
ontro
ller
BRO
WN
&RE
D (T
ERM
1 &
2)
BLU
E (T
ERM
#4)
BLU
E (T
ERM
#3)
U30
TER
MIN
AL
P/N
14-
1187
3
U30
TER
MIN
ALU
30 M
ICRO
PRO
CESS
OR
CON
TRO
LLER
LAB
EL
WHI
TETE
RM #
5
RED
TERM
#4
WHI
TEW
HITE
BLU
E
Electrical�Installation�Manual�U-30�Control� www.NabcoEntrances.comPart #15-10596-30 Rev. 1-10-14
5-18� Wiring�Diagrams�(Surface�Applied�Sliders)
Section 5e: (2) Wizard G3, and (1) Holding BeamTB
1
NO
ISE
FILT
ER
TB2
T1
S1
PENL
LOAD
-CIR
CUIT
- -B
REA
KER-
RED
IND
ICAT
ESPO
WER
IS O
FF
PRES
STO
RE
SET
POW
ER S
UPP
LYA
SSEM
BLY
P/N
941
8800
100
NA
BCO
14-1
1741
ENTR
AN
CES,
INC
.
071
2 3 4 56
7
8910
1112
>POM<
NA
BC
O
GY
RO
TEC
H
DS
-150
0 D
24-1
1327
0
Nab
tesc
o C
orpo
ratio
nMA
DEIN
JAPA
N
NA
BC
O
NA
BCO
MO
TOR/
OPE
RATO
R P/
N 2
4-11
327
Pow
er H
arne
ss P/
N 1
4-11
874
Grou
ndin
g W
ire
P/N
14-
1187
2
U30
MIC
ROPR
OCE
SSO
R CO
NTR
OLL
ER
P/N
24-
8901
-30
12VD
C Co
mm
on
12 V
DC+
12VD
C- (C
omm
on)
Hold
ing
Beam
Redu
ced
Ope
ning
Sw
itch
Mod
e Sw
itch
Brea
kout
Det
ecto
rSi
delit
e Pr
esen
ce S
enso
rCo
ntac
t Out
put (
Clas
s2 L
oad
only
)
30V
(42.
4V p
eak)
max
.5A
max
, (0-
20V)
, 3.2
A m
ax. (
20-3
0V)
Auxi
liary
Out
put (
Ope
n Co
llect
or)
N/O
N/C
Com
mon
9DC
12V
7
61
6B
H
M
0
M1
62
SQ
BA
SL
S
O
ut.A
Out
.B
O
ut.C
Out
7
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16Related Devices - 16P
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
Whi
te W
ire(C
omm
on)
Blac
k W
ire (H
ot)
RED
BRO
WN
RED
BLAC
KW
HITE
GREE
NO
RAN
GEO
RG/W
HTBL
K/RE
DBL
K/RE
D
GRN
/WHT
YELL
OW
DN 0
554
MAI
N H
ARN
ESS
FOR
U30
P/
N 2
4-11
877
BRO
WN
&RE
D (c
IRcU
It 1
& 2
)
ON
OFF
NIG
HT
TWO WAY
ON
E W
AY
HO
LD O
PE
N
FULLOPEN
RE
DU
CE
D O
PE
N
BLU
E
BLU
EBL
UE
WHI
TEW
HITE
WHI
TEW
HITE
KEY
SWIT
CH
FOR
U30
PN
14-
1187
6
ROCK
ER S
WIT
CH
FOR
U30
PN
14-
1187
5
BACK
SID
E O
F RO
CKER
SW
ITCH
SHO
WN
ROCK
ER S
WIT
CH
EXTE
NSI
ON
HAR
NES
S FO
R U
30
PN 1
4-11
884
ACU
SEN
SOR
EXTE
NSI
ON
HA
RNES
S PN
22-
9267
-00
ACU
SEN
SOR
EXTE
NSI
ON
HA
RNES
S PN
22-
9267
-00
OPT
EX
HOLD
ING
BEAM
CO
NTR
OLL
ER
PT. N
O.
PN 1
4-97
10-0
3TERM
#1
RED
BRO
WN
RED
BRO
WNBL
K RED
GRAY
YELL
OW
YELL
OW
GRAY
RED
RED
BLU
E
RED
ORA
NGE
ORG
/WHT
ORG
/WHT
RED
GREE
N
RED
ORA
NGE
RED
ORG
/WHT
BLU
EGR
EEN
ORA
NGE
Opt
ex O
S-1
2CC
ontro
ller
20VAC 50/60Hz
Micr
opro
cess
or C
ontro
ller
2489
01-
GY
RO
TE
CH
HOLD
OPE
NNI
GHT
ONE
WA Y
TWO
WAY
MODE
M1
M0 Open
Gnd
Open
Open
Open
GndG
nd Gnd
Mode
SW
Usa
ge
Adjus
tmen
ts to
the
door
can
only
be m
ade
with
the
NABC
O Ha
ndy T
erm
inal.
CAUT
ION
To m
aint
ain
warra
nty,r
epai
rs m
ust b
e m
ade
by a
utho
rized
NAB
CO fa
cilitie
s.
Do n
ot d
isass
emble
the
cont
rol b
ox.
Ther
e ar
e no
use
r ser
vicea
ble p
arts
inside
.
POWER・2PINDICATORS
61 6B H 62 BA
POWE
R
ERRO
RMOTO
R・12
PN
o.W
ARNI
NGTo
pro
tect
aga
inst
risk
of
fire
or e
lect
ric s
hock
,use
onl
y th
e ce
rtifie
d NA
BCO
pow
er s
uppl
y.
RELATED DEVICES・16P
HAND
Y TE
RMIN
AL・6
P
Mode
Swi
tch (s
ee M
ode S
W U
sage
show
n left
)
6179DC1
2V
6B
12VD
C+12
VDC-
(Com
mon)
Inte
rior A
ctiva
tion
Holdi
ng B
eam
M0H M1
SLS
62 BA
Exte
rior A
ctiva
tion
Side
lite P
rese
nce S
enso
rBr
eako
ut De
tector
1 2 3 4 5 6 7 8 9 10 11
Redu
ced O
penin
g Swi
tch
No.
SYMB
OLFU
NCTI
ON [S
LIDIN
G DO
OR]
712
VDC-
(Com
mon)
OUT.C
OUT.B
OUT.A
N/O
N/C
Comm
on
Conta
ct Ou
tput (
Clas
s2 Lo
ad on
ly)30
V(42
.4Vpe
ak)m
ax.
5Am
ax.(0
-20V
), 3.
2Am
ax.(2
0-30
V)OU
TAu
xiliar
y Out
put (
Open
-Coll
ecto
r)
SQSe
quen
tial A
ctiva
tion
1615141312
!!
!
! !
NABCO
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
POW
ER S
UPP
LY
P/N
14-
1174
1
AC11
5V ±
10%
50
/ 60
Hz
Auxi
liary
120
VAC
Po
wer
Wire
s (T
hese
wire
s are
ON
/OFF
Po
wer
Sw
itch
BLU
E
MAG
NET
IC P
OW
ER
DOW
N S
WIT
CH
P/N
22-
9222
BLU
EBL
ACK
WHI
TEGR
EEN
RED
BRO
WN
WHI
TE
WIZ
ARD
G3
PN 1
4-13
036
WIZ
ARD
G3
PN 1
4-13
036
U30
TER
MIN
ALU
30 M
ICRO
PRO
CESS
OR
CON
TRO
L LA
BEL
U30
TER
MIN
AL
P/N
14-
1187
3
BLAC
KBL
UE
GREE
N
RED
BRO
WN
Whi
te a
nd G
reen
wire
s fro
m S
enso
r pro
vide
out
put f
or
On
Rem
ote
Cont
rol S
et: “
F1”
to “
1”
If pr
ogra
mm
ing
with
out t
he R
emot
e: P
aram
eter
“13
” to
“1”
WHI
TETE
RM #
5
RED
TERM
#4
WHI
TEW
HITE
Rev. 1-10-14 Part #15-10596-30www.NabcoEntrances.com� Electrical�Installation�Manual�U-30�Control
Wiring�Diagrams�(Surface�Applied�Sliders)� 5-19
Section 5f: (2) Wizard G3, (1) Holding Beam and (1) Breakout BeamTB
1
NO
ISE
FILT
ER
TB2
T1
S1
PENL
LOAD
-CIR
CUIT
- -B
REA
KER-
RED
IND
ICAT
ESPO
WER
IS O
FF
PRES
STO
RE
SET
POW
ER S
UPP
LYA
SSEM
BLY
P/N
941
8800
100
NA
BCO
14-1
1741
ENTR
AN
CES,
INC
.
071
2 3 4 56
7
8910
1112
>POM<
NA
BC
O
GY
RO
TEC
H
DS
-150
0 D
24-1
1327
0
Nab
tesc
o C
orpo
ratio
nMA
DEIN
JAPA
N
NA
BC
O
NA
BCO
MO
TOR/
OPE
RATO
R P/
N 2
4-11
327
Pow
er H
arne
ss P/
N 1
4-11
874
Grou
ndin
g W
ire
P/N
14-
1187
2
U30
MIC
ROPR
OCE
SSO
R CO
NTR
OLL
ER
P/N
24-
8901
-30
12VD
C Co
mm
on
12 V
DC+
12VD
C- (C
omm
on)
Hold
ing
Beam
Redu
ced
Ope
ning
Sw
itch
Mod
e Sw
itch
Brea
kout
Det
ecto
rSi
delit
e Pr
esen
ce S
enso
rCo
ntac
t Out
put (
Clas
s2 L
oad
only
)
30V
(42.
4V p
eak)
max
.5A
max
, (0-
20V)
, 3.2
A m
ax. (
20-3
0V)
Auxi
liary
Out
put (
Ope
n Co
llect
or)
N/O
N/C
Com
mon
9DC
12V
7
61
6B
H
M
0
M1
62
SQ
BA
SL
S
O
ut.A
Out
.B
O
ut.C
Out
7
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
Related Devices - 16P
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
Whi
te W
ire(C
omm
on)
Blac
k W
ire (H
ot)
RED
BRO
WN
RED
BLAC
KW
HITE
GREE
NO
RAN
GEO
RG/W
HTBL
K/RE
DBL
K/RE
D
GRN
/WHT
YELL
OW
DN 0
555
MAI
N H
ARN
ESS
FOR
U30
P/
N 2
4-11
877
BRO
WN
&RE
D (T
ERM
1 &
2)
ON
OFF
NIG
HT
TWO WAY
ON
E W
AY
HO
LD O
PE
N
FULLOPEN
RE
DU
CE
D O
PE
N
BLU
E
BLU
EBL
UE
WHI
TEW
HITE
WHI
TEW
HITE
KEY
SWIT
CH
FOR
U30
PN
14-
1187
6
ROCK
ER S
WIT
CH
FOR
U30
PN
14-
1187
5
BACK
SID
E O
F RO
CKER
SW
ITCH
SHO
WN
ROCK
ER S
WIT
CH
EXTE
NSI
ON
HAR
NES
S FO
R U
30
PN 1
4-11
884
OPT
EX
HOLD
ING
BEAM
CO
NTR
OLL
ER
PT. N
O.
PN 1
4-97
10-0
3
TERM
#1
RED
BRO
WN
RED
BRO
WNBL
K
RED
BLU
E
RED
ORA
NGE
ORG
/WHT
ORG
/WHT
RED
GREE
N
RED
ORA
NGE
RED
ORG
/WHT
BLU
EGR
EEN
ORA
NGE
Opt
ex O
S-1
2CC
ontro
ller
20VAC 50/60Hz
Micr
opro
cess
or C
ontro
ller
2489
01-
GY
RO
TE
CH
HOLD
OPE
NNI
GHT
ONE
WA Y
TWO
WAY
MODE
M1
M0 Open
Gnd
Open
Open
Open
GndG
nd Gnd
Mode
SW
Usa
ge
Adjus
tmen
ts to
the
door
can
only
be m
ade
with
the
NABC
O Ha
ndy T
erm
inal.
CAUT
ION
To m
aint
ain
warra
nty,r
epai
rs m
ust b
e m
ade
by a
utho
rized
NAB
CO fa
cilitie
s.
Do n
ot d
isass
emble
the
cont
rol b
ox.
Ther
e ar
e no
use
r ser
vicea
ble p
arts
inside
.
POWER・2PINDICATORS
61 6B H 62 BA
POWE
R
ERRO
RMOTO
R・12
PN
o.W
ARNI
NGTo
pro
tect
aga
inst
risk
of
fire
or e
lect
ric s
hock
,use
onl
y th
e ce
rtifie
d NA
BCO
pow
er s
uppl
y.
RELATED DEVICES・16P
HAND
Y TE
RMIN
AL・6
P
Mode
Swi
tch (s
ee M
ode S
W U
sage
show
n left
)
6179DC1
2V
6B
12VD
C+12
VDC-
(Com
mon)
Inte
rior A
ctiva
tion
Holdi
ng B
eam
M0H M1
SLS
62 BA
Exte
rior A
ctiva
tion
Side
lite P
rese
nce S
enso
rBr
eako
ut De
tector
1 2 3 4 5 6 7 8 9 10 11
Redu
ced O
penin
g Swi
tch
No.
SYMB
OLFU
NCTI
ON [S
LIDIN
G DO
OR]
712
VDC-
(Com
mon)
OUT.C
OUT.B
OUT.A
N/O
N/C
Comm
on
Conta
ct Ou
tput (
Clas
s2 Lo
ad on
ly)30
V(42
.4Vpe
ak)m
ax.
5Am
ax.(0
-20V
), 3.
2Am
ax.(2
0-30
V)OU
TAu
xiliar
y Out
put (
Open
-Coll
ecto
r)
SQSe
quen
tial A
ctiva
tion
1615141312
!!
!
! !
NABCO
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
POW
ER S
UPP
LY
P/N
14-
1174
1
AC11
5V ±
10%
50
/ 60
Hz
Auxi
liary
120
VAC
Po
wer
Wire
s (T
hese
wire
s are
ON
/OFF
Po
wer
Sw
itch
MAG
NET
IC P
OW
ER
DOW
N S
WIT
CH
P/N
22-
9222
BLU
E
OPT
EX
BREA
KOU
T BE
AM
CON
TRO
LLER
PT
. NO
. PN
14-
9710
-03
TERM
#1
Opt
ex O
S-1
2CC
ontro
ller
BRO
WN
&RE
D (T
ERM
1 &
2)
BLU
E (T
ERM
#4)
BLU
E (T
ERM
#3)
U30
TER
MIN
AL
P/N
14-
1187
3
U30
TER
MIN
ALU
30 M
ICRO
PRO
CESS
OR
CON
TRO
LLER
LAB
EL
WHI
TETE
RM #
5
RED
TERM
#4
ACU
SEN
SOR
EXTE
NSI
ON
HA
RNES
S PN
22-
9267
-00
ACU
SEN
SOR
EXTE
NSI
ON
HA
RNES
S PN
22-
9267
-00
RED
GRAY
YELL
OW
YELL
OWGR
AYRE
D
BLU
EW
HITE
GREE
N
RED
BRO
WN
WHI
TE
WIZ
ARD
G3
PN 1
4-13
036
WIZ
ARD
G3
PN 1
4-13
036
BLAC
KBL
UE
GREE
N
RED
BRO
WN
Whi
te a
nd G
reen
wire
s fro
m S
enso
r pro
vide
out
put f
or
On
Rem
ote
Cont
rol S
et: “
F1”
to “
1”
If pr
ogra
mm
ing
with
out t
he R
emot
e: P
aram
eter
“13
” to
“1”
BLAC
K
WHI
TEW
HITE
BLU
E
Electrical�Installation�Manual�U-30�Control� www.NabcoEntrances.comPart #15-10596-30 Rev. 1-10-14
6-20� Infrared�Beam�Wiring
CHAPTER 6: INFRARED BEAM WIRING
Section 6a: Wiring (1) Holding Beam
On GT-1175 Slide doors, the Optex OS-12C Module Infrared Beam is installed and wired at the NABCO factory. This unit is shipped complete with the following:
►► Emitter
►► Receiver
►► Control BoxBoth the Emitter and Receiver are flush mounted on both sides of the Slide door Frame or each Jamb tube, directly across from each other. A pulsed, infrared light beam is used to continuously transmit across the Slide door opening. Interruption of the infrared light beam will switch the White holding beam input wire to Red (Common). Thus causing the system to re-activate and Hold Open until the interruption is cleared. Please Figure 6-1.
Figure 6-1 (1) Holding Beam using Optex OS-12C Controller
MOTOR/OPERATORP/N 24-11327
U30 MICROPROCESSOR CONTROL P/N 24-8901-30
POWER SUPPLY P/N 14-11741
TB1
NOISEFILTER
TB2
T1
S1
PEN
L
LOA
D
-CIRCUIT- -BREAKER-
RED INDICATESPOWER IS OFF
PRESSTO
RESET
POWER SUPPLYASSEMBLY
P/N 9418800100NABCO
14-11741ENTRANCES, INC.
0712
34 5 6 7
89
10
1112
>POM<
NABCO
GYRO TECH
DS-1500 D24-113270
Nabtesco CorporationMADE IN JAPAN
NABCO
NABCO
CAUTION!
RELA
TED
DEVIC
E S・ 1
6P
1213141516
No .
1110987654321
SYMBOL
HM0
9DC12V
SQ
OU TCommonN/CN/O OUT. A
OUT. BOUT. C
7
BA
62
SLS
M1
6B
761
Sequen�al Ac�va�on
Auxiliary Output (Open-Collector)5Amax.(0-20V), 3.2Amax.(20-30V)30V(42.4Vpeak)maxContact Output (Class2 Load only)
12VDC-(Common)
FUNCTION (SLIDING DOOR)
Reduced Opening Switch
Breakout DetectorSidelite Presence Sensor
Exterio r Ac�va�on
Holding BeamInterior Ac�va�o n12VDC-(Common)12VDC +
Mode Switch (see Mode SW Usage shown le�)
HANDY TERMINAL 6PNo.
248901- Microprocessor Controller
Mode SW Usage
Gn dGn dGn d
Open
OpenOpen
Gn dOpen
M0 M1 MODETWO WAYONE WAY
NIGH THOLD OPEN
To protect against risk of Fire or electric shock,use only the cer�fied NABCO power supply.
WARNINGMOTOR 12P
ERROR
POWER
BA
62
H
6B
61
INDICA
TORS
POWE
R2P
Do not disassemble the control box.There are no user serviceable parts inside.
To maintain warranty,repairs must be made by authorized NABCO facilities.
Adjustments to the door can only be madewith the NABCO Handy Terminal.
20VA
C 50/6
0Hz
GYRO TECHNABCO
!!
!
!
12VDC Common
12 VDC+ 12VDC- (Common)
Holding BeamReduced Opening SwitchMode Switch
Breakout DetectorSidelite Presence SensorContact Output (Class2 Load only)
30V (42.4V peak) max.5A max, (0-20V), 3.2A max. (20-30V)
Auxiliary Output (Open Collector)
N/ON/CCommon
9DC 12V 7 61 6B H M0 M1 62 SQ BA SLS Out.A Out.B Out.C Out 7
12345678910111213141516
Rela
ted
Devi
ces -
16P
123456789
10111213141516
DN 0547
CONNECT EACH TERMINAL
THE SAME
Braided Shield
Yellow Jacket Color
TERM #13 TERM #6
TERM #5TERM #1
Optex OS-12C Controller
P/N 14-9710-03
BLUE TERM #6
YELLOW TERM #7
GRAY TERM #10
YELLOWTERM #11
RED
GRAYEMTR 1
BLUE RCVR 1
U30 MICROPROCESSOR CONTROL LABEL U30 TERMINAL P/N 14-11873
BROWN & RED CIRCUIT 1 & 2
OTHER WIRES NOT SHOWNFOR SIMPLICITY
AC115V ± 10%50 / 60 Hz
WHITE
Rev. 1-10-14 Part #15-10596-30www.NabcoEntrances.com� Electrical�Installation�Manual�U-30�Control
Infrared�Beam�Wiring� 6-21
Section 6b: Wiring (2) Holding Beams
On GT-1175 Slide doors, the Optex OS-12C Module Infrared Beam is installed and wired at the NABCO factory. This unit is shipped complete with the following:
►► Emitter
►► Receiver
►► Control BoxBoth the Emitters and Receivers are flush mounted on both sides of the Slide door Frame or each Jamb tube, directly across from each other (in pairs). Please see Figure 6-2 and Figure 6-3.
DN 0549
Emit Rcvr
EmitRcvr
①
②
Figure 6-2 Transmission of Infrared Light Beams
A pulsed, infrared light beam is used to continuously transmit across the Slide door opening. Interruption of the infrared light beam will switch the White holding beam input wire to Red (Common). Thus causing the system to re-activate and Hold Open until the interruption is cleared.
Figure 6-3 (2) Holding Beams using Optex OS-12C Controller
DN 0548
OTHER WIRES NOT SHOWN FOR SIMPLICITY
CONNECT EACH TERMINAL
THE SAME
Plas� c ConductorBraided Shield
Yellow Jacket Color
TERM #13 TERM #6
TERM #5 TERM #1
Optex OS-12CController
P/N 14-9710-03
TO AUXILIARYPOWERSUPPLY
TO U30 CONTROLLER
TERMINAL
BLUERCVR 1
GRAYEMTR 1
GRAYEMTR 2
BLUERCVR 2
BLUETERM #6
YELLOWTERM #7
GRAYTERM #12
YELLOWTERM #13
BLUETERM #8
YELLOWTERM #9
GRAYTERM #10
YELLOWTERM #11
Electrical�Installation�Manual�U-30�Control� www.NabcoEntrances.comPart #15-10596-30 Rev. 1-10-14
6-22� Infrared�Beam�Wiring
Section 6c: Wiring Holding Beam for Breakout
On GT-1175 Slide doors, the Optex OS-12C Module Infrared Beam is installed and wired at the NABCO factory. This unit is shipped complete with the following:
►► Emitter
►► Receiver
►► Control BoxBoth the Emitter and Receiver are flush mounted on both sides of the Slide door Frame or each Jamb tube, directly across from each other. A pulsed, infrared light beam is used to continuously transmit across the Slide door opening. Interruption of the infrared light beam. By Breaking Out a Slide door panel the Blue (BA) wire power down loop will be interrupted. Thus causing the system to stop operating until the Slide door is repositioned and latched. Please see Figure 6-4.
MOTOR/OPERATORP/N 24-11327
U30 MICROPROCESSOR CONTROL P/N 24-8901-30
POWER SUPPLY P/N 14-11741
TB1
NOISEFILTER
TB2
T1
S1
PEN
L
LOA
D
-CIRCUIT- -BREAKER-
RED INDICATESPOWER IS OFF
PRESSTO
RESET
POWER SUPPLYASSEMBLY
P/N 9418800100NABCO
14-11741ENTRANCES, INC.
0712
34 5 6 7
89
10
1112
>POM<
NABCO
GYRO TECH
DS-1500 D24-113270
Nabtesco CorporationMADE IN JAPAN
NABCO
NABCO
CAUTION!
RELA
TED
DEVIC
E S・ 1
6P
1213141516
No .
1110987654321
SYMBOL
HM0
9DC12V
SQ
OU TCommonN/CN/O OUT. A
OUT. BOUT. C
7
BA
62
SLS
M1
6B
761
Sequen�al Ac�va�on
Auxiliary Output (Open-Collector)5Amax.(0-20V), 3.2Amax.(20-30V)30V(42.4Vpeak)maxContact Output (Class2 Load only)
12VDC-(Common)
FUNCTION (SLIDING DOOR)
Reduced Opening Switch
Breakout DetectorSidelite Presence Sensor
Exterio r Ac�va�on
Holding BeamInterior Ac�va�o n12VDC-(Common)12VDC +
Mode Switch (see Mode SW Usage shown le�)
HANDY TERMINAL 6PNo.
248901- Microprocessor Controller
Mode SW Usage
Gn dGn dGn d
Open
OpenOpen
Gn dOpen
M0 M1 MODETWO WAYONE WAY
NIGH THOLD OPEN
To protect against risk of Fire or electric shock,use only the cer�fied NABCO power supply.
WARNINGMOTOR 12P
ERROR
POWER
BA
62
H
6B
61
INDICA
TORS
POWE
R2P
Do not disassemble the control box.There are no user serviceable parts inside.
To maintain warranty,repairs must be made by authorized NABCO facilities.
Adjustments to the door can only be madewith the NABCO Handy Terminal.
20VA
C 50/6
0Hz
GYRO TECHNABCO
!!
!
!
12VDC Common
12 VDC+ 12VDC- (Common)
Holding BeamReduced Opening SwitchMode Switch
Breakout DetectorSidelite Presence SensorContact Output (Class2 Load only)
30V (42.4V peak) max.5A max, (0-20V), 3.2A max. (20-30V)
Auxiliary Output (Open Collector)
N/ON/CCommon
9DC 12V 7 61 6B H M0 M1 62 SQ BA SLS Out.A Out.B Out.C Out 7
12345678910111213141516
Rela
ted
Devi
ces -
16P
123456789
10111213141516
DN 0547
CONNECT EACH TERMINAL
THE SAME
Braided Shield
Yellow Jacket Color
TERM #13 TERM #6
TERM #5TERM #1
Optex OS-12C Controller
P/N 14-9710-03
BLUE TERM #6
YELLOW TERM #7
GRAY TERM #10
YELLOWTERM #11
RED
GRAYEMTR 1
BLUE RCVR 1
U30 MICROPROCESSOR CONTROL LABEL U30 TERMINAL P/N 14-11873
BROWN & RED CIRCUIT 1 & 2
OTHER WIRES NOT SHOWNFOR SIMPLICITY
AC115V ± 10%50 / 60 Hz
BLUE
Figure 6-4 Breakout Beam using Optex OS-12C Controller
Rev. 1-10-14 Part #15-10596-30www.NabcoEntrances.com� Electrical�Installation�Manual�U-30�Control
Electric�Lock�Wiring� 7-23
CHAPTER 7: ELECTRIC LOCK WIRINGNote: Electric Locks can not prevent Breakout. If preventing Breakout is deemed necessary, panic
hardware must be fitted to the Door Panels.
The Electric Lock is optional and can come in (1 of 2) configurations:
►► Fail Safe• Allows the Door Panel to be manually opened if power is turned Off.
►► Fail Secure• Will not allow the Door Panal to be manually opened if power is turned Off.
Electric Locks are used to prevent Door Panels from opening until they are activated by the U30 Microprocessor Control when it receives a signal from a:
►► Remote Switch►► Transmitter►► Activation Device on the face of the Door
Electric Locks are pre-installed at the NABCO Factory. Only the Strike mounted on the Header may need to be adjusted.
Section 7a: Adjust the Strike.
1.►Close Door Panel(s).
2.►Go inside the Header. Loosen the Strike Mounting Bolts that is holding the Strike Bracket secure to the Header.
3.►Slide the Strike to align with the Latch Bolt in the fully closed position.
4.►Tighten the Strike Mounting Bolts.
a. Do not overtighten.
Figure 7-1 Adjust the Strike
DN 1026
Electric Lock Assembly
LATCHBOLT POSITION:• BI�PART UNITS• LH SINGLE F.O.• RH SINGLE F.S.
LATCHBOLT POSITION:• RH SINGLE F.O.• LH SINGLE F.S.
Dead Bolt Assembly
Belt Clip
Electric StrikeDead Bolt Engaged with Electric Strike(Door in Full Closed Posi� on)
Slight Gap(Between Strike Walland Dead Bolt)
Terminal Strip(Strike Side of Door)
Electrical�Installation�Manual�U-30�Control� www.NabcoEntrances.comPart #15-10596-30 Rev. 1-10-14
7-24� Electric�Lock�Wiring
Section 7b: U30 with Fail Safe Electric Lock
Note: Fail Safe Electric Lock only works in One Way mode or Night Mode.
12V
DC
-CO
MM
ON
Aux
iliar
y O
utpu
t (O
pen-
Col
lect
or)
Seq
uent
ial A
ctiv
atio
n
5Am
ax.(0
-20V
), 3.
2Am
ax.(2
0-30
V)
30V
(42.
4Vpe
ak)m
ax.
Con
tact
Out
put (
Cla
ss2
Load
onl
y )
FUN
CTI
ON
[SLI
DIN
G D
OO
R]
RE
DU
CE
D O
PE
NIN
G S
WIT
CH
Bre
akou
t Det
ecto
rS
idel
ite P
rese
nce
Sen
sor
Ext
erio
r Act
ivat
ion
HO
LDIN
G B
EA
MIN
TER
IOR
AC
TIVA
TIO
N12
VD
C-(
CO
MM
ON
)12
VD
C+
Mod
e S
witc
h (s
ee M
ode
SW
Usa
ge s
how
n le
ft)
Com
mon
N/C
N/O
SQ
OU
T
OU
T.A
OU
T.B
OU
T.C
7SY
MB
OL
BA62 SLS
M1
H M0
6B9DC
12V
7 61
12 13 14 15 16No. 1110987654321
RELATED DEVICES - 16P1 2 3 4 5 6 7 8 9 10 11 1615141312
AC
TIVA
TIO
N S
IGN
AL
OU
TPU
T S
IGN
AL
FULL
Y C
LOS
ED
OP
EN
ING
FULL
OP
EN C
LOS
ING
FULL
Y C
LOS
ED
OU
TPU
T : 0
= E
LEC
TRIC
STR
IKE
OU
TPU
T
OU
TPU
T TI
ME
R0
=(D
O N
OT
US
E)
1 =
(DO
NO
T U
SE
)2
=(D
O N
OT
US
E)
3 =
ELE
CTR
IC S
TRIK
E F
UN
CTI
ON
U30
ELE
CTR
IC S
TRIK
E O
UTP
UT
SIG
NA
LH
AN
DY
TER
MIN
AL:
AU
X O
UTP
UT
= 0,
OU
TPU
T TI
ME
R =
3,
RO
CK
ER
SW
ITC
H S
ETT
ING
: ON
E W
AY O
R N
IGH
T M
OD
E
OU
TPU
T TI
ME
R1.
0 S
EC
3 S
EC
ON
ON
OFF O
FF
120
VAC
LAB
EL
ON
U30
CO
NTR
OL
AC
115V
± 1
0%50
/ 60
Hz B
LAC
K (H
OT)
SC
RE
W T
O H
EA
DE
R
WH
ITE
(CO
MM
ON
)
GR
OU
ND
LU
G
MADE IN JAPAN
(24-11
327)
DS
-150NA
GY
RO
TEC
H
ON
/OFF
PO
WE
R
SW
ITC
H
TRANSFORMER
A M P5TB
1
NO
ISE
FILT
ER
TB2
T1
S1
ZNR2
ZNR1
AU
XIL
IAR
Y 12
0 VA
CP
OW
ER
WIR
ES
(TH
ES
E W
IRE
S N
OR
MA
LLY
CO
ILE
D A
ND
TIE
D U
P)
MO
TOR
/OP
ER
ATO
R P
/N 2
4-11
327
U30
CO
NTR
OL
P/N
24-
8901
-30
PO
WE
R S
UP
PLY
P/N
14-
1174
1
GR
OU
ND
HA
RN
ES
SP
/N 1
4-11
872
PO
WE
R S
UP
PLY
HA
RN
ES
SP
/N 1
4-11
874
VIO
LET
GR
AY
TER
MIN
AL
ON
U30
MA
IN H
AR
NE
SS
P/N
24-
1187
7W
IRIN
G F
OR
ELE
CTR
IC L
OC
K O
NLY
SH
OW
N
FAIL
SA
FE L
OC
K A
SS
Y.
P.N
. 22-
1052
2-04
1211
1098
6
4 3 2
170
>POM
<
FAIL
SA
FE
VIO
GR
Y
WH
TB
LK
1 6
110V
1 2 3 4 5 6 7 8 9 10 11 1615141312
20VAC 50/60Hz
Mic
ropr
oces
sor C
ontro
ller
2489
01-
GY
RO
TE
CH
HO
LD O
PE
NN
IGH
T
ON
E W
AYTW
O W
AYM
OD
EM
1M
0O
pen
Gnd
Ope
nO
pen
Ope
nG
ndG
ndG
nd
Mod
e S
W U
sage
Adj
ustm
ents
to th
e do
or c
an o
nly
be m
ade
with
the
NA
BC
O H
andy
Ter
min
al.
CA
UTI
ON
To m
aint
ain
war
rant
y,re
pairs
mus
t be
mad
e by
aut
horiz
ed N
AB
CO
faci
litie
s.
Do
not d
isas
sem
ble
the
cont
rol b
ox.
Ther
e ar
e no
use
r ser
vice
able
par
ts
POWER・2PINDICATORS
61 6B H 62 BA
PO
WE
R
ER
RO
R
MO
TOR・1
2PN
o.W
AR
NIN
GTo
pro
tect
aga
inst
risk
of
fire
or e
lect
ric s
hock
,use
onl
y th
e ce
rtifie
d N
AB
CO
pow
er s
uppl
y.
RELATED DEVICES・16P
HA
ND
Y TE
RM
INA
L・6P
Mod
e S
witc
h (s
ee M
ode
SW
Usa
ge s
how
n le
ft)
617 6B
12V
DC
+12
VD
C-(
Com
mon
)In
terio
r Act
ivat
ion
Hol
ding
Bea
m
M0
H M1
SLS
62 BA
Ext
erio
r Act
ivat
ion
Sid
elite
Pre
senc
e S
enso
rB
reak
out D
etec
tor
1 2 3 4 5 6 7 8 9 10 11
Red
uced
Ope
ning
Sw
itch
No.
FUN
CTI
ON
[SLI
DIN
G D
OO
R]
712
VD
C-(
Com
mon
)
OU
T.C
OU
T.B
OU
T.A
N/O
N/C
Com
mon
Con
tact
Out
put (
Cla
ss2
Load
onl
y)30
V(4
2.4V
peak
)max
.5A
max
.(0-2
0V),
3.2A
max
.(20-
30V
)O
UT
Aux
iliar
y O
utpu
t (O
pen-
Col
lect
or)
SQ
Seq
uent
ial A
ctiv
atio
n
1615141312
SY
MB
OL
9DC
12V
FAIL
SE
CU
RE
(OU
T A
)FA
IL S
AFE
(OU
T B
)
FAIL
SE
CU
RE
LO
CK
AS
SY
. P
.N. 2
2-10
522-
03
OTH
ER
WIR
ES
NO
T S
HO
WN
FOR
SIM
PLI
CIT
Y
HAN
DY T
ERM
INAL
HAR
NES
S P/
N 1
4-11
837
DN 0
551
Rev. 1-10-14 Part #15-10596-30www.NabcoEntrances.com� Electrical�Installation�Manual�U-30�Control
Electric�Lock�Wiring� 7-25
Section 7c: U30 with Fail Secure Electric Lock
Note: Fail Secure Electric Lock only works in One Way mode or Night Mode.
120
VAC
LAB
EL
ON
U30
CO
NTR
OL
AC
115V
± 1
0%50
/ 60
Hz B
LAC
K (H
OT)
SC
RE
W T
O H
EA
DE
R
WH
ITE
(CO
MM
ON
)
GR
OU
ND
LU
G
MADE IN JAPAN
(24-11
327)
DS
-150NA
GY
RO
TEC
H
ON
/OFF
PO
WE
R
SW
ITC
HTRANSFORMER
A M P5TB
1
NO
ISE
FILT
ER
TB2
T1
S1
ZNR2
ZNR1
AU
XIL
IAR
Y 12
0 VA
CP
OW
ER
WIR
ES
(TH
ES
E W
IRE
S N
OR
MA
LLY
CO
ILE
D A
ND
TIE
D U
P)
MO
TOR
/OP
ER
ATO
R P
/N 2
4-11
327
AC
TIVA
TIO
N S
IGN
AL
OU
TPU
T S
IGN
AL
OFF
OFF
ON
ON
FULL
Y C
LOS
ED
OP
EN
ING
FULL
OP
EN C
LOS
ING
FULL
Y C
LOS
ED
OU
TPU
T: 0
= E
LEC
TRIC
STR
IKE
OU
TPU
T
OU
TPU
T TI
ME
R0
=(D
O N
OT
US
E)
1 =
(DO
NO
T U
SE
)2
=(D
O N
OT
US
E)
3 =
ELE
CTR
IC S
TRIK
E F
UN
CTI
ON
U30
ELE
CTR
IC S
TRIK
E O
UTP
UT
SIG
NA
LH
AN
DY
TER
MIN
AL:
AU
X O
UTP
UT
= 0,
OU
TPU
T TI
ME
R =
3,
RO
CK
ER
SW
ITC
H S
ETT
ING
: ON
E W
AY O
R N
IGH
T M
OD
E
OU
TPU
T TI
ME
R1.
0 S
EC
3 S
EC
U30
CO
NTR
OL
P/N
24-
8901
-30
PO
WE
R S
UP
PLY
P/N
14-
1174
1
GR
OU
ND
HA
RN
ES
SP
/N 1
4-11
872
PO
WE
R S
UP
PLY
HA
RN
ES
SP
/N 1
4-11
874
VIO
LET
GR
AY (O
UT
A)
TER
MIN
AL
ON
U30
MA
IN H
AR
NE
SS
P/N
24-
1187
7W
IRIN
G F
OR
ELE
CTR
IC L
OC
K O
NLY
SH
OW
NFA
IL S
EC
UR
E L
OC
K A
SS
Y.P.
N. 2
2-10
522-
03
FAIL
SE
CU
RE
VIO
GR
Y
WH
TB
LK
1 6
110V
20VAC 50/60Hz
Mic
ropr
oces
sor C
ontro
ller
2489
01-
GY
RO
TE
CH
HO
LD O
PE
NN
IGH
T
ON
E W
AYTW
O W
AYM
OD
EM
1M
0O
pen
Gnd
Ope
nO
pen
Ope
nG
ndG
ndG
nd
Mod
e S
W U
sage
Adj
ustm
ents
to th
e do
or c
an o
nly
be m
ade
with
the
NA
BC
O H
andy
Ter
min
al.
CA
UTI
ON
To m
aint
ain
war
rant
y,re
pairs
mus
t be
mad
e by
aut
horiz
ed N
AB
CO
faci
litie
s.
Do
not d
isas
sem
ble
the
cont
rol b
ox.
Ther
e ar
e no
use
r ser
vice
able
par
ts
insi
de.
POWER・2PINDICATORS
61 6B H 62 BA
PO
WE
R
ER
RO
R
MO
TOR・1
2PN
o.W
AR
NIN
GTo
pro
tect
aga
inst
risk
of
fire
or e
lect
ric s
hock
,use
onl
y th
e ce
rtifie
d N
AB
CO
pow
er s
uppl
y.
RELATED DEVICES・16P
HA
ND
Y TE
RM
INA
L・6P
Mod
e S
witc
h (s
ee M
ode
SW
Usa
ge s
how
n le
ft)
617 6B
12V
DC
+12
VD
C-(
Com
mon
)In
terio
r Act
ivat
ion
Hol
ding
Bea
m
M0
H M1
SLS
62 BA
Ext
erio
r Act
ivat
ion
Sid
elite
Pre
senc
e S
enso
rB
reak
out D
etec
tor
1 2 3 4 5 6 7 8 9 10 11
Red
uced
Ope
ning
Sw
itch
No.
FUN
CTI
ON
[SLI
DIN
G D
OO
R]
712
VD
C-(
Com
mon
)
OU
T.C
OU
T.B
OU
T.A
N/O
N/C
Com
mon
Con
tact
Out
put (
Cla
ss2
Load
onl
y)30
V(4
2.4V
peak
)max
.5A
max
.(0-2
0V),
3.2A
max
.(20-
30V)
OU
TA
uxili
ary
Out
put (
Ope
n-C
olle
ctor
)
SQ
Seq
uent
ial A
ctiv
atio
n
1615141312
12V
DC
-CO
MM
ON
Aux
iliar
y O
utpu
t (O
pen-
Col
lect
or)
Seq
uent
ial A
ctiv
atio
n
5Am
ax.(0
-20V
), 3.
2Am
ax.(2
0-30
V)
30V
(42.
4Vpe
ak)m
ax.
Con
tact
Out
put (
Cla
ss2
Load
onl
y)
FUN
CTI
ON
[SLI
DIN
G D
OO
R]
RE
DU
CE
D O
PE
NIN
G S
WIT
CH
Bre
akou
t Det
ecto
rS
idel
ite P
rese
nce
Sen
sor
Ext
erio
r Act
ivat
ion
HO
LDIN
G B
EA
MIN
TER
IOR
AC
TIVA
TIO
N12
VD
C-(
CO
MM
ON
)12
VD
C+
Mod
e S
witc
h (s
ee M
ode
SW
Usa
ge s
how
n le
ft)
Com
mon
N/C
N/O
SQ
OU
T
OU
T.A
OU
T.B
OU
T.C
7SY
MB
OL
BA62 SLS
M1
H M0
6B9DC
12V
7 61
12 13 14 15 16No. 1110987654321
RELATED DEVICES - 16P
1 2 3 4 5 6 7 8 9 10 11 1615141312
1 2 3 4 5 6 7 8 9 10 11 1615141312
SY
MB
OL
9DC
12V
HAN
DY T
ERM
INAL
HAR
NES
S P/
N 1
4-11
837
DN 0
552
Electrical�Installation�Manual�U-30�Control� www.NabcoEntrances.comPart #15-10596-30 Rev. 1-10-14
7-26� Electric�Lock�Wiring
Section 7d: U30 with Magnetic Lock
Note: Magnetic Lock only works in One Way mode or Night Mode.
Belt
Clip
Bo�
om
Term
inal
Str
ip
Belt
Brac
ket
Rela
y
Belt
Clip
Top
Term
inal
Str
ip
Belt
Brac
ket
Rela
y
DN 0
534
SIN
GLE
SLI
DE
DO
OR;
RH
FS, L
HFO
BI�P
ART
SLI
DE
DO
OR
Mot
or/O
pera
tor
U-1
9 &
Ear
lier
Mot
or/O
pera
tor
U-1
9 &
Ear
lier
Mot
or/O
pera
tor
U-1
9 &
Ear
lier
Belt
Clip
Top
Belt
Clip
Top
11 1
1/16
11 1
1/16
8 5/
16
SIN
GLE
SLI
DE
DO
OR;
LH
FS, R
HFO
Rev. 1-10-14 Part #15-10596-30www.NabcoEntrances.com� Electrical�Installation�Manual�U-30�Control
Custom�Wiring� 8-27
CHAPTER 8: CUSTOM WIRING
Section 8a: U30 Configured for Remote Control of Modes
DN 0
553DN
055
3Fr
om D
N 0
291
12V
DC
-CO
MM
ON
Aux
iliar
y O
utpu
t (O
pen-
Col
lect
or)
Seq
uent
ial A
ctiv
atio
n
5Am
ax.(0
-20V
), 3.
2Am
ax.(2
0-30
V)30
V(4
2.4V
peak
)max
.C
onta
ct O
utpu
t (C
lass
2 Lo
ad o
nly)
FUN
CTI
ON
[SLI
DIN
G D
OO
R]
RE
DU
CE
D O
PE
NIN
G S
WIT
CH
Bre
akou
t Det
ecto
rS
idel
ite P
rese
nce
Sen
sor
Ext
erio
r Act
ivat
ion
HO
LDIN
G B
EA
MIN
TER
IOR
AC
TIV
ATIO
N12
VD
C-(
CO
MM
ON
)12
VD
C+
Mod
e S
witc
h (s
ee M
ode
SW
Usa
ge s
how
n le
ft)
Com
mon
N/C
N/O
SQ
OU
T
OU
T.A
OU
T.B
OU
T.C
7SY
MB
OL
BA62 SLS
M1
H M0
6B9DC
12V
7 61
12 13 14 15 16No.
1110987654321
RELATED DEVICES - 16P
1 2 3 4 5 6 7 8 9 10 11 1615141312
Con
tact
1
Con
tact
2
Mod
eC
onta
ct 1
C
onta
ct 2
Two
Way
(Aut
o)
Ope
n O
pen
One
Way
Mod
e(E
xit O
nly)
Ope
n C
lose
d
N
ight
Mod
e C
lose
d O
pen
H
old
Ope
n C
lose
d C
lose
d
GR
EE
NO
RA
NG
EO
RG
/WH
T
BLU
E
OR
AN
GE
GR
EE
N
RE
DO
RG
/WH
TB
LUE
LAB
EL
ON
U30
CO
NTR
OL
TER
MIN
AL
ON
U30
CO
NTR
OL
P/N
14-
1187
3
RO
CK
ER
SW
ITC
H
EX
TEN
SIO
N H
AR
NE
SS
FOR
U30
PT.
14-
1188
4-10
CU
T R
OC
KE
R S
WIT
CH
E
XTE
NS
ION
HA
RN
ES
S
AN
D S
PLI
CE
AS
SH
OW
N
NO
TES
:1.
BLU
E W
IRE
MU
ST
BE
CO
NN
ETE
D T
O
RE
D F
OR
DO
OR
TO
OP
ER
ATE
.2.
IT IS
RE
CO
ME
ND
ED
TH
AT
PAR
T N
UM
BE
R
14-1
1884
-10
BE
US
ED
FO
R T
HE
SE
M
OD
IFIC
ATIO
NS
. TH
IS W
OU
LD A
LLO
W
CH
AN
GE
S T
O, O
R R
EV
ER
SA
L O
F M
OD
IFIC
ATIO
NS
TO
BE
MA
DE
EA
SIE
R.
3.O
THE
R W
IRE
S N
OT
SH
OW
N F
OR
SIM
PLI
CIT
Y4.
RE
MO
TE S
WIT
CH
MU
ST
BE
DR
Y C
ON
TAC
TS
(NO
VO
LTAG
E)
5.C
AP
OFF
ALL
UN
US
ED
WIR
ES
OR
AN
GE
GR
EE
N
RE
DO
RG
/WH
TB
LUE
RE
D
OR
AN
GE
OR
G/W
HT
RE
D
Electrical�Installation�Manual�U-30�Control� www.NabcoEntrances.comPart #15-10596-30 Rev. 1-10-14
8-28� Custom�Wiring
Section 8b: Sidelite SensorsTB
1
NO
ISE
FILT
ER
TB2
T1
S1
PENL
LOAD
-CIR
CUIT
- -B
REA
KER-
RED
IND
ICAT
ESPO
WER
IS O
FF
PRES
STO
RE
SET
POW
ER S
UPP
LYA
SSEM
BLY
P/N
941
8800
100
NA
BCO
14-1
1741
ENTR
AN
CES,
INC
.
071
2 3 4 56
7
8910
1112
>POM<
NA
BC
O
GY
RO
TEC
H
DS-
1500
D
24-1
1327
0
Nab
tesc
o C
orpo
ratio
nMA
DEIN
JAPA
N
NA
BC
O
NA
BCO
12VD
C Co
mm
on
12 V
DC+
12VD
C- (C
omm
on)
Hold
ing
Beam
Redu
ced
Ope
ning
Sw
itch
Mod
e Sw
itch
Brea
kout
Det
ecto
rSi
delit
e Pr
esen
ce S
enso
rCo
ntac
t Out
put (
Clas
s2 L
oad
only
)
30V
(42.
4V p
eak)
max
.5A
max
, (0-
20V)
, 3.2
A m
ax. (
20-3
0V)
Auxi
liary
Out
put (
Ope
n Co
llect
or)
N/O
N/C
Com
mon
9DC
12V
7
61
6B
H
M
0
M1
62
SQ
BA
SL
S
O
ut.A
Out
.B
O
ut.C
Out
7
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
Related Devices - 16P
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
20VAC 50/60Hz
Micr
opro
cess
or C
ontro
ller
2489
01-
GY
RO
TE
CH
HOLD
OPE
NNI
GHT
ONE
WAY
TWO
WAY
MODE
M1
M0 Open
Gnd
Open
Open
Open
GndG
nd Gnd
Mode
SW
Usa
ge
Adjus
tmen
ts to
the
door
can
only
be m
ade
with
the
NABC
O Ha
ndy T
erm
inal.
CAUT
ION
To m
aint
ain
warra
nty,r
epai
rs m
ust b
e m
ade
by a
utho
rized
NAB
CO fa
cilitie
s.
Do n
ot d
isass
emble
the
cont
rol b
ox.
Ther
e ar
e no
use
r ser
vicea
ble p
arts
inside
.
POWER・2PINDICATORS
61 6B H 62 BA
POWE
R
ERRO
RMOTO
R・12
PN
o.W
ARNI
NGTo
pro
tect
aga
inst
risk
of
fire
or e
lect
ric s
hock
,use
onl
y th
e ce
rtifie
d NA
BCO
pow
er s
uppl
y.
RELATED DEVICES・16P
HAND
Y TE
RMIN
AL・6
P
Mode
Swi
tch (s
ee M
ode S
W U
sage
show
n left
)
6179DC1
2V
6B
12VD
C+12
VDC-
(Com
mon)
Inte
rior A
ctiva
tion
Holdi
ng B
eam
M0H M1
SLS
62 BA
Exte
rior A
ctiva
tion
Side
lite P
rese
nce S
enso
rBr
eako
ut De
tector
1 2 3 4 5 6 7 8 9 10 11
Redu
ced O
penin
g Swi
tch
No.
SYMB
OLFU
NCTI
ON [S
LIDIN
G DO
OR]
712
VDC-
(Com
mon)
OUT.C
OUT.B
OUT.A
N/O
N/C
Comm
on
Conta
ct Ou
tput (
Clas
s2 Lo
ad on
ly)30
V(42
.4Vpe
ak)m
ax.
5Am
ax.(0
-20V
), 3.
2Am
ax.(2
0-30
V)OU
TAu
xiliar
y Out
put (
Open
-Coll
ecto
r)
SQSe
quen
tial A
ctiva
tion
1615141312
!!
!
! !
NABCO
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
MOTO
R/OPE
RATO
R P/N�24-11
327
Power�Harne
ss
P/N�14-11
874
Grou
nding�Wire
P/N�14-11
872
U30
�MICRO
PROCE
SSOR�CO
NTR
OL
P/N�24-89
01-30
White�W
ire(Com
mon
)
Black�Wire
�(Hot)
RED
GRN/W
HT
DN 0
546
POWER
�SUPP
LY
P/N�14-11
741
AC11
5V�±�10%
50
�/�60
�Hz
Auxiliary�120
�VAC
Po
wer�W
ires
(The
se�wire
s�are
no
rmally�coiled
and�tie
d�up
)
ON/O
FF
Power�Switch
WHITE
U30
�TER
MINAL
P/N�24-11
877
U30
�TER
MINAL
U30
�MICRO
PROCE
SSOR�CO
NTR
OL�LA
BEL
GREEN
REDBLACK
GREENWHITE
BLACKRED
CUT�AC
USENSO
R EX
TENSION�HAR
NESS
AND�SPLICE
�AS�SH
OWN
SIDE
LITE�ACU
SENSO
R P/N�14-89
02SIDE
LITE�ACU
SENSO
R P/N�14-89
02
Rev. 1-10-14 Part #15-10596-30www.NabcoEntrances.com� Electrical�Installation�Manual�U-30�Control
Custom�Wiring� 8-29
Section 8c: U30 Using Card Readers or other Secure Activation Devices
KEY PAD OR CARD READER ONSECURE SIDE OF DOOR(N.O. - DRY CONTACTS)
12VDC Common
12 VDC+12VDC- (Common)
Interior Ac� va� onHolding BeamReduced Opening SwitchMode Switch (See Mode SW Usage Shown Le� )
Exterior Ac� va� onSequen� al Ac� va� onBreakout DetectorSidelite Presence SensorContact Output (Class2 Load only)
30V (42.4V peak) max.5A max, (0-20V), 3.2A max. (20-30V)
Auxiliary Output (Open Collector)
N/ON/CCommon
9DC 12V 7 61 6B H M0 M1 62 SQ BA SLS Out.A Out.B Out.C Out 7
12345678910111213141516
Rela
ted
Devi
ces -
16P
123456789
10111213141516
DN 0545
NON�SECURE ACTIVATION DEVICES SUCH AS PUSH PLATES CAN ALSO BE CONNECTED TO THE INTERIOR
�TERMINAL 3 AND COMMON¡ OR EXTERIOR �TERMINAL 8 AND COMMON¡ ACTIVATION INPUTS. THIS WILL ALLOW THEM TO BE TURNED OFF OR ON
BY USING THE MODE SWITCHES �TWO WAY, ONE WAY, NIGHT¡
TERM #11
N.O.
COM
U30 TERMINALP/N 24-11877
U30 MICROPROCESSOR CONTROL LABELP/N 24-8901-30
TERM #2
1. “FUNCTION 13” UNDER “EXTRA FUNCTIONS” MUST BE SET TO “3”.2. “FUNCTION 13” SET TO 3 ENABLES THE “SLS” INPUT TO ACTIVATE THE
DOOR REGARDLESS OF THE MODE (AUTO, ONE WAY, NIGHT).3. DEVICE MUST PROVIDE NORMALLY OPEN, DRY CONTACTS (NO VOLTAGE).4. OTHER WIRES NOT SHOWN FOR SIMPLICITY.
Electrical�Installation�Manual�U-30�Control� www.NabcoEntrances.comPart #15-10596-30 Rev. 1-10-14
9-30� Troubleshooting
CHAPTER 9: TROUBLESHOOTING
Trouble ActionSlide door panicked open. System fails to shut down.
Check wiring on the magnetic power down switches. Blue (BA) circuit must open for system to shut down.
Slide door does not open when power is applied.
Do Not manually shut door.
X Confirm the Breakout Panel(s) is closed completely. X Confirm Blue (BA) circuit is not open.
• Verification can be done by observing Green (BA) status LED on U30 Controller. If LED in ON, the circuit is Open, and the unit will not operate.
X Check that the power down magnet in the top rail of the Breakout panel is installed and aligned with the magnetic power down switch in the bottom of the Header.
X Confirm Rocker Switch is set to ON not OFF.Handy Terminal screen does not change.
X Confirm the Breakout Panel(s) is closed completely. X Confirm Blue (BA) circuit is not open.
• Verification can be done by observing Green (BA) status LED on U30 Controller. If LED in ON, the circuit is Open, and the unit will not operate.
X Check that the power down magnet in the top rail of the Breakout panel is installed and aligned with the magnetic power down switch in the bottom of the Header.
X Confirm Rocker Switch is set to ON not OFF.Door opens and closes very slowly.
X Check and clear error codes with Handy Terminal. X If Handy Terminal is not available, cycling the power will make the control
resume normal operation.Slide doors do not Open completely.
X Look for obstructions in the track as well as inside the Header.• Check to ensure that Belt Clips are not hitting something.
X Check that the Mode Switch on the panel is not in “Reduced Opening” mode.Also verify that the Green (H) status LED on the U30 Controller is not lit. If this LED is ON, it indicates that there is a signal on the “Reduced Opening” circuit (Green “H” is being shorted to Red 7)
X Use the Handy Terminal and reintialize the system.Reset the system back to NABCO Factory settings
X Plug in Handy Terminal and wait for the Slide door to Close.1. At�“Swing/Slide�Stroke?”�enter�YES.2. At�“Swing�Door�Y�or�N?”�enter�YES�(even�though�you�have�a�slide�door).
a. “Swing Door Y or N?” enter NO.b. System will now intialize as a Slide door to NABCO Factory settings.
3. Set�Slide�door�Stroke�according�to�prompts�the�Handy�Terminal�displays.�
Rev. 1-10-14 Part #15-10596-30www.NabcoEntrances.com� Electrical�Installation�Manual�U-30�Control
Return�Policy� 10-31
CHAPTER 10: RETURN POLICY
Note: Please call Customer Service if the Return Material tag number is not known at 1-888-679-3319.
A Return Material tag is used for:
►► In Warranty and Out of Warranty materials.
►► Repair and Return.
►► Return for Credit Transactions.
NABCO ENTRANCES Standard Term & Conditions and Warranty govern all returned items. These are provided in detail in the Terms & Conditions section of NABCO ENTRANCES Price Book. If you have any questions on warranty or the use of the RMA tag, please call NABCO’s Customer Service Department toll free at 1-888-679-3319.
Section 10a: How to Print and Fill out a Return Material Tag
1.►Go to the NABCO Website at http://nabcoentrances.com/
a. The NABCO homepage will be displayed.
2.►Go to the left hand column. Under “Quick Links” click on:
RMA LABELS
3.►Enter the RMA number. Click on:
RMA LOOKUP
4.►Fill out all necessary contact information. Click on:
GENERATE A LABELa. An assigned RMA tag will be displayed.
5.►Print the assigned RMA tag.
a. The RMA tag is printed in triplicate.
6.►Record following information on the tag:
X Serial No. or Part No. • Serial numbers for electronic components are stamped, engraved or printed on
stickers and located on the component. Non-electrical parts usually do not have serial numbers.
X Part Name (description) X Expiration Date
• Expiration dates for electronic components are stamped, engraved or printed on stickers and located on the component. Non-electrical parts usually do not have expiration dates. For “Warranty claims of non-electrical parts”, please include a photocopy of the original NABCO invoice the part was purchased on.
Electrical�Installation�Manual�U-30�Control� www.NabcoEntrances.comPart #15-10596-30 Rev. 1-10-14
10-32� Return�Policy
X Date Returned• The date that the malfunctioning Unit or Part is returned to NABCO Entrances INC.
X Requested Repair and Return Action• Specify in/out warranty for R&R, Exchange, or in warranty for credit. For requests for
credits, please write the number of the invoice you want credited.
X Distributor Name X Date of Installation X Installed at Job X Describe part problem
7.►Attach an RMA tag to each malfunctioning Unit or Part that is returned to the NABCO factory.
8.►The RMA tag is printed in triplicate. Please keep (top) copy of the tag.
9.►Send remaining (2) copies along with each malfunctioning Unit or Part to the attention of:
REPAIR AND RETURN DEPARTMENT AT NABCO ENTRANCES. a. Please remember to package the malfunctioning Unit and/or Parts properly.
10.►Ship the parts freight prepaid.
a. Collect shipments will be refused.
Note: All return inquiries must be accompanied with the RMA tag number associated with the malfunctioning Unit and/or part.