MOBILE SPOT COOLER Service Manual
![Page 2: MOBILE SPOT COOLER Service Manual€¦ · MOBILE SPOT COOLER Service Manual. Troubleshooting 1.Repair form Check 2.Confilm cause 3.Repair . Repair contents It is not out of cold air](https://reader033.fdocuments.us/reader033/viewer/2022050204/5f57ab53ea48c025e47903dd/html5/thumbnails/2.jpg)
Troubleshooting
1.Repair form Check
2.Confilm cause
3.Repair
![Page 3: MOBILE SPOT COOLER Service Manual€¦ · MOBILE SPOT COOLER Service Manual. Troubleshooting 1.Repair form Check 2.Confilm cause 3.Repair . Repair contents It is not out of cold air](https://reader033.fdocuments.us/reader033/viewer/2022050204/5f57ab53ea48c025e47903dd/html5/thumbnails/3.jpg)
Repair contents
It is not out of cold air
Gas leak=Gas filling or Product exchange
Compressor trouble=Product exchange
Overload relay trouble=Overload relay exchange
Filter・condenser・evaporator dust =Clean up
Compressor condenser trouble=Compressor condenser exchange
![Page 4: MOBILE SPOT COOLER Service Manual€¦ · MOBILE SPOT COOLER Service Manual. Troubleshooting 1.Repair form Check 2.Confilm cause 3.Repair . Repair contents It is not out of cold air](https://reader033.fdocuments.us/reader033/viewer/2022050204/5f57ab53ea48c025e47903dd/html5/thumbnails/4.jpg)
Fan motor trouble=Fan motor Exchange
Not working
Substrate trouble=Exchange
Power cord breakdown=Exchange
Switch trouble=Switch Exchange
Fan motor condenser trouble=Exchange
Repair contents
![Page 5: MOBILE SPOT COOLER Service Manual€¦ · MOBILE SPOT COOLER Service Manual. Troubleshooting 1.Repair form Check 2.Confilm cause 3.Repair . Repair contents It is not out of cold air](https://reader033.fdocuments.us/reader033/viewer/2022050204/5f57ab53ea48c025e47903dd/html5/thumbnails/5.jpg)
Not swing
Swing parts or Swing belt trouble=Exchange
Swing switch trouble=Swing switch Exchange
Water leak Drain case=Drain case Clean up
Parts break Exchange
Swing motor trouble=Swing motor Exchange
![Page 6: MOBILE SPOT COOLER Service Manual€¦ · MOBILE SPOT COOLER Service Manual. Troubleshooting 1.Repair form Check 2.Confilm cause 3.Repair . Repair contents It is not out of cold air](https://reader033.fdocuments.us/reader033/viewer/2022050204/5f57ab53ea48c025e47903dd/html5/thumbnails/6.jpg)
⑦ Complaint case No Content Answer
① Cold wind not out A cord is long ※No move compressor
② The whole room not cold It is a machine to cool at a spot
③ use it generator? Use a generator of the capacity of 4~5times
④ This machine is driven 24hour Possible
⑤ Electricity bill of one hour Electricity bill answer
⑥ Put the water No
⑦ Distribution duct None
⑧ Cool air temperature Environmental temperature=35℃ cool air temperature=about 25℃
⑨ Use timer Possible but after 3minutes of turning off
⑩ N407-TC & SAC-4500 only Stop the swing?
Choose the switch