MLZ18 - MLZ24 SASO Wall Mounted Mini Split Available in 1.5 & 2 Ton Heat Pump / Cool only Models Customer Service: 92 0000 468 www.zamilac.com Head Office Zamil Air Conditioners P.O.Box 14440 Dammam - 31424, KSA Fax: +966 3 8471904 DAMMAM - (03) 847 3333 JUBAIL - (03) 341 6666 RIYADH - (01) 472 5555 QASSIM - (06) 364 6198 MADINAH - (04) 846 3771 YANBU - (04) 321 2151 TABUK - (04) 423 2840 JEDDAH - (02) 234 3630 GIZAN - (07) 321 3915 ABHA - (07) 221 5999 MAKKAH - (02) 546 4167 4-Way Auto Swing 99% Anti Bacteria Free Filter Carbon Filter Bio Filter

description

HVAC

Transcript of MLZ18-24

Page 1: MLZ18-24

MLZ

18 -

MLZ

24

SASO

Wall Mounted Mini Split Available in1.5 & 2 Ton

Heat Pump/ Cool only Models

Customer Service: 92 0000 468

www.zamilac.com

Head OfficeZamil Air ConditionersP.O.Box 14440Dammam - 31424, KSAFax: +966 3 8471904

DAMMAM - (03) 847 3333JUBAIL - (03) 341 6666RIYADH - (01) 472 5555

QASSIM - (06) 364 6198MADINAH - (04) 846 3771YANBU - (04) 321 2151TABUK - (04) 423 2840

JEDDAH - (02) 234 3630GIZAN - (07) 321 3915ABHA - (07) 221 5999MAKKAH - (02) 546 4167

4-Way Auto Swing

99%Anti Bacteria Free Filter Carbon Filter Bio Filter

Page 2: MLZ18-24

CONTINUOUS RESEARCH RESULTS IN STEADY IMPROVEMENTS. THEREFORE, THESE SPECIFICATIONS ARE SUBJECT TO CHANGE W ITHOUT NOTICE.NOTE: 1. Cooling capacity and power input data @ 27º C DB / 19°C WB Indoor temperature & 35ºC DB outdoor temperature - ISO 5151 2. Heating capacity & power input data @ Indoor 20º C DB / 15º WB Indoor temperature & 7ºC Outdoor temperature. At outdoor temperature less than -2 deg C, other source of heating must be used. 3. Refrigerant charge for outdoor units suitable for 7.5 meters of interconnecting pipe, for exact charge refer outdoor unit Nameplate. 4. Sound Pressur level is measured at a distance of 1 mtr. In Hemi Anechoic room.

MLZ18 - 24 / KZC18 - 24

Auto Mode: AC will run either in cool or heat based on the difference between the set temperature and room temperature to keeprequired set temperature in the room automatically

Sleep Mode: In sleep mode the air conditioner automatically increase the set temperature (cool mode) or decrease the set temperature(heat mode) in regular intervals to keep comfort during sleep

Hydrophilic Blue Fins: By use of Blue hydrophilic fins water drops accumulation will be reduced.This improves heat exchanger capacity by reducing airresistance passing through heat exchanger

High Effeciency Heat Exchanger - IGT + Fins: High efficiency heat exchangers are designed by use of inner grooved tubes bonded by enhanced fins

Compressor Tested up to 60 Deg C: Compressors are tested upto 60°C ensure smooth operation atadverse ambient conditions

Rotary Compressor: Powerful Rotary compressor is used to deliver more capacitywith less power consumption for better efficiencies

Outdoor Unit

Indoor Unit

Auto Restart: When Power is switched OFF & switched ON, the air conditioner will restart automatically with the previous setting by itself uponresuming the power

BLUE

MODEL #INDOOR UNIT

OUTDOOR UNIT

BLOWER MOTOR

COMPRESSOR

CONDENSER FAN MOTOR

SOUND PRESSURE LEVEL (1M), dBA

COOLING CAPACITY, (Watts)

POWER INPUT, (Watts) / EER

HEATING CAPCITY, (Watts)

POWER INPUT ( Watts) / C.O.P

MODE OF OPERATION

NO. OF STARS

POWER SUPPLY

EVAPORATOR AIRFLOW (HIGH /MEDIUM / LOW), CFM

MAXIMUM FUSE SIZE/CIRCUIT BREAKER, AMPS(INDOOR/OUTDOOR UNIT)

COMPRESSOR

NET WEIGHT, KG

REFRIGERANT CHARGE, (Kg)

LIQUID - SUCTION - DRAIN PIPE DIA., INCHES

MINIMUM CIRCUIT AMPACITY, AMPS(INDOOR / OUTDOOR UNIT)

DIMENSIONS (LxWxH), MM

MLZ18CCIXFTV MLZ18CHIXFTV MLZ24CCIXFTV MLZ24CHIXFTV

KZC18CSACIV KZC18CSAHIV KZC24CSGCIV KZC24CSGHIV

HEAT PUMP HEAT PUMP

1

1

2

2

FLA / LRA, AMPS

FLA / POWER INPUT, (Watts)

RLA / LRA, AMPS

INDOOR UNIT

OUTDOOR UNIT

INDOOR UNIT

OUTDOOR UNIT

INDOOR UNIT

OUTDOOR UNIT

COOL ONLY COOL ONLY

5,041 5,012 6,448 6,448

1801 / 9.55 1790 / 9.55 2245 / 9.80 2303 / 9.55

NA 4,300 NA 6,125

NA 1600/ 2.68 NA 2155 / 2.84

450/370/285 450/370/285 590/560/475 590/560/475

42/38/34 42/38/34 50/44/41 50/44/41

ROTARY

1.588 1.503 1.644 1.928

230-1-60

230-1-60

0.25 / 55 0.26 / 58

7.70 / 43 9.35 / 60.8

1.0 / 1.42 1.0 / 1.42

3/8, 5/8,3/4. 3/8, 5/8,3/4.

0.33 / 12.1 0.40/16.8

5 / 20 5/25

12 12

52 54

13 13

60 62

920X223X292 998X240X322

800x325x685 800x325x685

ON & OFF Timer 24 hours: The timer ON / OFF feature is used to turn OFF the air conditioneror turn ON the air conditioner automatically at set time by user

Turbo: Turbo feature is used for instant cooling or heating.During Turbo mode the set temperature and fan speeds are preset

TURBO

NORMAL

Bio Filter 4-Way AutoSwing

Dry Mode Self DiagnosisSystem

Anti ColdWind Protection

Auto Defrost

4-Way Auto Swing: The air direction in the room can be set by louver movementin horizontal & vertical direction.

IGT –

MLZ18 24 / KZC18 24