MLM 226 Faceplates Installation Guide -...
Transcript of MLM 226 Faceplates Installation Guide -...
1MLM 226 Faceplates • Installation Guide
MLM 226 Faceplates Installation Guide
MLM 226 FaceplatesThis guide provides instructions for installing the following Extron MediaLink™
Mounting Options faceplates, which are designed for use with the MLC 226 IPMediaLink Controller.
The MLM 226 L, MLM 226 3GWP, or MLM 226 5GWP faceplate is shippedwith the MLC 226 IP controller, depending on the controller configuration that isordered. The rest of the mounting options described below may be orderedseparately as replacements, or for use with an MLC 226 IP that is ordered withouta faceplate.
• MLM 226 L — A low-profile, 3.15" H x 6.50" W (8.0 cm H x 16.5 cm W) lectern/furniture-mounting faceplate. This faceplate is required when you are mountingan MLC 226 IP using an optional UCM RAAP or UCM 10X8P mounting kit.Part numbers: 70-342-02 (black), 70-342-03 (white), 70-342-05 (RAL9010 white)
• MLM 226 LAAP — A low-profile, 3.15" H x 10.00" W (8.0 cm H x 25.40 cm W)lectern/furniture-mounting faceplate with an opening that accommodates foursingle-space AAPsPart numbers: 70-343-02 (black), 70-343-03 (white), 70-343-05 (RAL9010 white)
• MLM 226 3GWP — A three-gang (4.50" H x 6.40" W [11.43 cm H x 16.26 cm W])faceplate that can be mounted to a mud ring (mounting bracket), an ExtronSurface Mount Box, an Extron External Wall Box, or a standard electrical boxPart numbers: 70-376-02 (black), 70-376-03 (white), 70-376-05 (RAL9010 white)
68-919-01, Rev. D08 07
MLM 226 Faceplates Installation Guide, cont’d
MLM 226 Faceplates • Installation Guide2
• MLM 226 5GWP — A five-gang (4.50" H x 10.04" W [11.43 cm H x 25.50 cmW]) faceplate with an opening that accommodates four single-space AAPs. Itcan be mounted to a mud ring, an Extron Surface Mount Box, an ExtronExternal Wall Box, or a standard electrical box.Part numbers: 70-377-02 (black), 70-377-03 (white), 70-377-05 (RAL9010white)
• MLM 226 7GWP — A seven-gang (4.50" H x 13.665" W [11.43 cm H x34.71 cm W]) faceplate with two openings that accommodate four single-space AAPs each (eight AAPs total). It can be mounted to a mud ring, anExtron Surface Mount Box, an Extron External Wall Box, or a standardelectrical box.Part numbers: 70-340-02 (black), 70-340-03 (white), 70-340-05 (RAL9010white)
Replacing an MLC 226 IP Faceplate with an MLMFaceplate
1. If your MLC controller is already installed in a wall or furniture, remove thefour screws that attach it to its mounting surface (marked a in the diagramon the next page), and lift it out.
2. After the MLC has been removed from the wall or furniture, use a smallPhillips screwdriver to remove the four faceplate attachment screws (b in thediagram on the next page), and save them for later use.
CAUTION Do not remove the four faceplate screws while the MLC is installed in awall or furniture, or the controller may fall down into the wall orfurniture.
3MLM 226 Faceplates • Installation Guide
Extron MLC 226 IP
DISPLAY
1 2 3 4 5 6
VOLUME
CONFIG IR
ON OFF PICMUTE
VCR DVD
PC AUTOIMAGE
LAPTOPDOCCAM
1 1
11
2
2 2
2
3. Lift the faceplate off the MLC 226 IP, as shown below.
OFF
ON
PC VCR
DVD
DOC
CAM
PIC
MUTE
AUTO
IMAGE
LAPTOP
Extron
DISPLAY1
2
3
4
5
6
VOLUME CONFIG
IR
MLC 226 IP
4. Align the openings in the new MLM faceplate with the controller’s buttons,knob, and LEDs, then place the new faceplate on the MLC 226 IP.
5. Replace the four screws removed in step 2, and hand tighten them.
6. Install the MLC 226 IP controller with the MLM 226 faceplate in a wall orfurniture as appropriate.
MLM 226 Faceplates Installation Guide, cont’d
MLM 226 Faceplates • Installation Guide4
TemplatesUse one of the following templates as a guide to measure and mark the hole forinstalling the MLM 226 faceplate with an attached MLC 226 IP. (Refer to yourMLC 226 IP user’s manual for instructions on preparing the mounting site.)
CAUTION These templates are not to scale. Use the dimensions shown in thetemplates as reference guidelines for measuring and drawing the rectanglethat will be cut out.
The MLC controller requires a depth of at least 2.0" (5.1 cm) inside the wall orfurniture.
MLM 226 L and MLC 226 IP L template
6.5" (16.5 cm)
Cut-Out Template for Extron's MLM 226 L and MLC 226 IP L
TEMPLATE IS NOT FULL SIZE.
To install MLC 226 IPand MLM 226 Ldirectly into furniture,cut along this line.
Top Panel
2.9" (7.4 cm)
5.4" (13.7 cm)
SURFACE CUT-OUT AREA FOR FURNITURE MOUNT
3.15" (8.0 cm)
Location of MLC 226 IP
.295" (0.75 cm)
(4 places)
.250" (0.64 cm)
(4 places)
5MLM 226 Faceplates • Installation Guide
MLM 226 LAAP template
.250" (0.64 cm)
2.9" (7.4 cm)
8.9" (22.6 cm)
SURFACE CUT-OUT AREA FOR
FURNITURE MOUNT
10" (25.4 cm)
Cut-Out Template for Extron's MLM 226 LAAP
TEMPLATE IS NOT FULL SIZE.
To install MLC 226 IPand MLM 226 LAAP directly into furniture,cut along this line.
Top Panel
Location of MLC 226 IP
3.15" (8.0 cm)
.295" (0.75 cm)
MLM 226 Faceplates Installation Guide, cont’d
MLM 226 Faceplates • Installation Guide6
MLM 226 3GWP and MLC 226 IP template
6.4"(16.26 cm)
Cut-Out Template for Extron's MLM 226 3GWP and MLC 226 IP
TEMPLATE IS NOT FULL SIZE.
To install MLC 226 IPand MLM 226 3GWPdirectly into furniture,cut along this line.
Top Panel
2.9"(7.4 cm)
5.4"(13.7 cm)
SURFACE CUT-OUT AREAFOR FURNITURE MOUNT
4.5"(11.4 cm)
Location of MLC 226 IP
7MLM 226 Faceplates • Installation Guide
MLM 226 5GWP and MLC 226 IP AAP template
2.9" (7.4 cm)
8.9" (22.6 cm)
SURFACE CUT-OUT AREA FOR
FURNITURE MOUNT
10.04"(25.5 cm)
Cut-Out Template for Extron's MLM 226 5GWP and MLC 226 IP AAP
TEMPLATE IS NOT FULL SIZE.
To install MLC 226 IP and MLM 226 5GWP directly into furniture, cut along this line.
Top Panel
Location of MLC 226 IP
4.5" (11.4 cm)
MLM 226 Faceplates Installation Guide, cont’d
MLM 226 Faceplates • Installation Guide8 © 2007 Extron Electronics. All rights reserved.
Extron Electronics, USA1230 South Lewis StreetAnaheim, CA 92805800.633.9876 714.491.1500 FAX 714.491.1517
Extron Electronics, EuropeBeeldschermweg 6C3821 AH Amersfoort, The Netherlands+800.3987.6673 +31.33.453.4040FAX +31.33.453.4050
Extron Electronics, Asia135 Joo Seng Rd. #04-01PM Industrial Bldg., Singapore 368363+800.7339.8766 +65.6383.4400 FAX +65.6383.4664
Extron Electronics, JapanKyodo Building, 16 IchibanchoChiyoda-ku, Tokyo 102-0082Japan+81.3.3511.7655 FAX +81.3.3511.7656www.extron.com
MLM 226 7GWP template
2.9" (7.4 cm)
12.7"(32.3 cm)
SURFACE CUT-OUT AREA FOR
FURNITURE MOUNT
13.665"(34.71 cm)
Cut-Out Template for Extron's MLM 226 7GWP
TEMPLATE IS NOT FULL SIZE.
To install MLC 226 IP and MLM 226 7GWP directly into furniture, cut along this line.
Top Panel
Location of MLC 226 IP
4.5" (11.4 cm)