mitsubishi 2.pdf

66

Click here to load reader

Transcript of mitsubishi 2.pdf

MITSUBISHIELECTRICFACTORY AUTOMATIONMoulded-Case Circuit Breakers /// Disconnectors ///NF-S /// NF-H/// NF-R/// NF-U///WorldSuper SeriesMITSUBISHIOFFONNO-FUSE BREAKERNF125-SGWIn A 100Ir 63-100AMODELPOLEUi690VCat.APUSH TOTRIPUimp 8kV3 PIEC60947-2JIS C 8201-2Ue690VAC525VAC500VAC440VAC380/415VAC230VACEN60947-240CIcu/Ics8/8kA22/22kA30/30kA36/36kA36/36kA85/85kAMITSUBISHI ELECTRICPAL 70%50/60HzTTsTL IiIsIrIpIi(X100A)Ir(A) TL(S) IS(xIr) TS(S)Ip(xIr)63 100 100 12 22.510 .06.07 .10.3 468 101214.1 .2876 5 4 80 3.5360 80OVER MODELRE100 In 100AMITSUBISHIOFFONNO-FUSE BREAKERNF125-SGWIn A 100Ir 63-100AMODELPOLEUi690VCat.APUSH TOTRIPUimp 8kV3 PIEC60947-2JIS C 8201-2Ue690VAC525VAC500VAC440VAC380/415VAC230VACEN60947-240CIcu/Ics8/8kA22/22kA30/30kA36/36kA36/36kA85/85kAMITSUBISHI ELECTRICPAL 70%50/60HzTTsTL IiIsIrIpIi(X100A)Ir(A) TL(S) IS(xIr) TS(S)Ip(xIr)63 100 100 12 22.510 .06.07 .10.3 468 101214.1 .2876 5 4 80 3.5360 80OVER MODELRE100 In 100AMITSUBISHIOFFONNO-FUSE BREAKERNF125-SGWIn A 100Ir 63-100AMODELPOLEUi690VCat.APUSH TOTRIPUimp 8kV3 PIEC60947-2JIS C 8201-2Ue690VAC525VAC500VAC440VAC380/415VAC230VACEN60947-240CIcu/Ics8/8kA22/22kA30/30kA36/36kA36/36kA85/85kAMITSUBISHI ELECTRICPAL 70%50/60HzTTsTL IiIsIrIpIi(X100A)Ir(A) TL(S) IS(xIr) TS(S)Ip(xIr)63 100 100 12 22.510 .06.07 .10.3 468 101214.1 .2876 5 4 80 3.5360 80OVER MODELRE100 In 100AMITSUBISHIOFFONNO-FUSE BREAKERNF125-SGWIn A 100Ir 63-100AMODELPOLEUi690VCat.APUSH TOTRIPUimp 8kV3 PIEC60947-2JIS C 8201-2Ue690VAC525VAC500VAC440VAC380/415VAC230VACEN60947-240CIcu/Ics8/8kA22/22kA30/30kA36/36kA36/36kA85/85kAMITSUBISHI ELECTRICPAL 70%50/60HzTTsTL IiIsIrIpIi(X100A)Ir(A) TL(S) IS(xIr) TS(S)Ip(xIr)63 100 100 12 22.510 .06.07 .10.3 468 101214.1 .2876 5 4 80 3.5360 80OVER MODELRE100 In 100A2 MITSUBISHI ELECTRICTechnical catalogue System QProduct catalogues for programmable logic controllers andaccessories for the further MELSEC PLC seriesTechnical catalogue Alpha and FX familyProduct catalogues for programmable logic controllers andaccessories for the Alpha and FX familiesTechnical catalogue Frequency invertersProduct catalogue for frequency inverters and accessoriesTechnical catalogues MELSERVOand Motion ControllersProduct catalogues for servo motors and amplifiers of theMR-J2S Series and Motion Controllers with SSCNETTechnical catalogue RobotsProduct catalogue for MELFA industrial robots and accessoriesFurther Publications within the Factory Automation RangeMore information?This technical catalogue is designed to give an overviewof the extensive range of moulded-cas circuit breakers of the World SuperSeries and related accessories. If you cannot find the information you require in this catalogue, there are a number of ways you can getfurther details on configuration and technical issues, pricing and availability.For technical issues visit the www.mitsubishi-automation.comwebsite.Our website provides a simple and fast way of accessing further technical data and up to the minute details on our products andservices. Manuals and catalogues are available in several different languages and can be downloaded for free.For technical, configuration, pricing and availability issues contact our distributors and partners.Mitsubishi partners and distributors are only too happy to help answer your technical questions or help with configuration building.For a list of Mitsubishi partners please see the back of this catalogue or alternatively take a look at the contact ussection of our website.About this technical catalogueThis catalogue is a guide to the range of products available. For detailed configuration rules, systembuilding, installation and configura-tion the associated product manuals must be read. You must satisfy yourself that any systemyou design with the products in this cata-logue is fit for purpose, meets your requires and conforms to the product configuration rules as defined in the product manuals.Specifications are subject to change without notice. All trademarks acknowledged.Mitsubishi Electric Europe B.V., Factory Automation - European Business Group, 12/2007, 5th edition3 MITSUBISHI ELECTRIC/// CONTENTSDas Inhalts-verzeichnis wird nach der Freigabe aktualisiert!1Introduction and Configuration Circuit Breakers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Electronic Breakers. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 Calculation and Selection Software MELSHORT2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 Product Skeleton of Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 Model Overviewand Specifications. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 102Circuit Breakers Specifications of Moulded-Case Circuit Breakers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 Specifications of Switches / Disconnectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 Order information of Circuit Breakers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 223Internal Accessories Introduction and Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24 AlarmSwitch and Auxiliary Switch. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26 Shunt Trip Device. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28 Undervoltage Tripping Device . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 304External Accessories Accessories for Connection and Installation. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35 Operating Handles. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36 Handle Lock Devices . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37 Electrically Operated Breakers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38 Terminal Covers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40 Mechanical Interlocks, Insulating Barriers, Rail Adapter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41 Tester for Electronic Breakers. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 424 MITSUBISHI ELECTRICINTRODUCTIONANDCONFIGURATION/// INTRODUCTIONANDCONFIGURATIONWorld Super Series WSS The Extensive Breaker Series from Mitsubishi ElectricWSS World Super SeriesThe newWSS breaker series meetsnational and international protection rat-ings according to VDE, EN, and IEC stan-dards for industrial applications as well asfor extended shipping demands.The newtripping technology guarantees ahigh reliability and highest protection. 16 to 250 A in one model size (3- and4-pole) interchangeable relay unit (thermaltype or electronic type) available in fixed and plug-in versions breaking capacityIcs = 100 %Icu, up to 690 VThe proven Progressive Super Series fea-tures technical know-howand the micro-processor technology tried and tested inlongstanding experience.The fully enclosed circuit breakers providean increased safety and at the same timedecreased switching times. 400 to 800 A 2 model sizes (3- and 4-pole) electronic trip system available in fixed and plug-in versions additional disconnectors availableThe proven standard series for a highbreaking performance providing an opti-mumprotection for transformer and gen-erator feed in, and output breakers.Circuit breakers can be used as section ordisconnecting switch. 1000 to 1600 A 1 model size (3- and 4-pole) electronic trip system available in fixed and plug-in versionsIntelligent BreakingTechnology for Your SafetyWith its innovative breaking technology allMitsubishi breakers offer greater safetyand even faster circuit-breaking speedthrough the use of the latest switch-offtechnology and innovative engineering,with a newly developed electronic triprelay.The circuits of the Mitsubishi breaker series are amongst the small-est compact circuit breakers in the world with electronic overloadindication of this kind.The systemis based, among other things, on the well-known andproven microprocessor technology.BreakingperformanceThe complete rangeof moulded casecircuit breakers from3 to 1600 A .200HWSWSW12532 6357,536455070758510kAAFUGWRGWHGWSGWUEWREWHEWSEWSEW125/160/250 400/630/800 1000/1250/1600MITSUBISHIOFFONNO-FUSE BREAKERNF125-SGWIn A 125Ir 80-125AMODELPOLEUi690VCat.APUSH TOTRIPUimp 8kV3 PIEC60947-2JIS C 8201-2Ue690VAC525VAC500VAC440VAC380/415VAC230VAC300VACEN60947-240CIcu/Ics8/8kA22/22kA30/30kA36/36kA36/36kA85/85kA20/20kAMITSUBISHI ELECTRICPAL 70%50/60HzTTs TL Ii IsIrIpIi(X100A)Ir(A) TL(S) IS(xIr) TS(S) Ip(xIr)63 100 100 12 22.5 10 .06 .07 .10 .3 468 101214.1 .2876 5 4 80 3.53 60 80OVER MODELRE100 In 100AJISUe550VAC460VAC220VACIEC 60947-2EN 60947-2500VAC250VACIcn35kA50kA85kAIcu/Ics10/10kA30/30kA42/42kA45/45kA85/85kA40C50kA85kAMITSUBISHI ELECTRICOFFONMITSUBISHINO-FUSE BREAKERNF400-SEP400A400MODELPOLEUi 690VAC50 - 60Hz8kVPUSH TOTRIPUimp3 PIp(xIr)TESTTL(sec) TS(sec)100 1260 80IS(xIr)22.5 10876 5 3003504 3.53.06 .3.1 .2Ii(X400A)468 10121614.07 .10Ir(A)200220250400TTs TL Ii IsIrIpMITSUBISHINO-FUSE BREAKERNF1000-SSIn A 1000Ir 500-1000AMODELPUSH TOTRIPIEC60947-2EN60947-2Ue690VAC500VAC440VAC400VAC230VACCat. BIcu/Ics25/13kA65/33kA85/43kA85/43kA125/63kAIcw 20kA 0.1sMITSUBISHI ELECTRICOVERCURRENTTS TESTTERMINALsec.TL2 2.5 1087 6 5 0.91.04 3.5 3G SI i abc deLoHi00.1 0.3 0.2IR (xIn) IS (xIR)0.50.70.8NF125-SGWRT, 3p NF400-SEW, 3p NF1000-SEW, 3p(ICUat 400 V AC)5 MITSUBISHI ELECTRICINTRODUCTIONANDCONFIGURATIONINTRODUCTIONANDCONFIGURATION///MITSUBISHIOFFONNO-FUSE BREAKERNF125-SGWIn A 100Ir 63-100AMODELPOLEUi690VCat.APUSH TOTRIPUimp 8kV3 PIEC60947-2JIS C 8201-2Ue690VAC525VAC500VAC440VAC380/415VAC230VAC300VACEN60947-240CIcu/Ics8/8kA22/22kA30/30kA36/36kA36/36kA85/85kA20/20kAMITSUBISHI ELECTRICPAL 70%50/60HzTTsTLIiIsIrIpIi(X100A)Ir(A) TL(S) IS(xIr) TS(S)Ip(xIr)63 100 100 12 22.510 .06.07 .10.3 468 101214.1 .2876 5 480 3.5360 80OVERMODELRE100 In 100AHandle Trip indicationThe automatically tripped condition isindicated by the handle in the centerposition between ON and OFF; the yel-lowor white line cannot be seen in thisposition.The figure shows the handle in trippedposition. ResettingResetting after tripping is performed byfirst moving the handle OFF position toengage the mechanism, then returningthe handle to ON to reclose the circuit. Trip-FreeEven if the handle is held at ON, thebreaker will trip if an overcurrent flows. Contact on MechanismEven in the worst case in which weldingoccurs owing to an overcurrent, thebreaker will trip and the handle willmaintain to ON, indicating the energiz-ing state.PAL 70%50/60HzTTsTL IiIsIrIpIi(X100A) Ir(A) TL(S) IS(xIr) TS(S) Ip(xIr)63 100 100 12 22.510 .06 .07 .10 .3 468 101214.1 .28765 4 803.5360 80OVERMODELRE100 In 100A Adjustable thermal trip current valueThe setting can be changed by simplyturning the control dials, providing theoptimumcharacteristics for particularroad conditions.Arc runnerThe arc is instantaneously trans-ferred to the arc-extinguishingchamber (see the figure above)by the arc runner, which reducesdamage to contacts andimproves interrupting perfor-mance.Arc-extinguishing deviceMitsubishi MCCBs feature excellentarc-extinguishing performance byvirtue of the optimumcombinationof grid gap, shape, and material.Magnetic fluxArc extinctionMagneticforceSwitching mechanismThe contacts open and close rapidly,regardless of the moving speed of the han-dle, minimizing contact wear and ensuringsafety.Moulded case (cover)Type NF125-SGWconstructionTrip button (push to trip)Enables tripping mechanicallyfromoutside, for confirming theoperation of the accessoryswitches and the manualresetting function.OutlineNewbreaking technologyWith its newbreaking technology thecircuit breakers offer greater safety andeven faster circuit-breaking speedthrough the use of the latest switch-offtechnology and innovative engineering,with a newly developed electronic triprelay.Trip relay with control dialsGridArcRapidmovement4 567810 468 1012141632100.06 .3.1.2.7.8 .91.06012150300350250225200In(A)TESTTL(s) TS(s) IP(In, Ir)IS(In, Ir ) II(400A).5.7 .81Ir(400A)6 MITSUBISHI ELECTRICINTRODUCTIONANDCONFIGURATION/// INTRODUCTIONANDCONFIGURATIONA Microcomputer and Mitsubishis Original IC fulfill a New High Level of SafetySafer and more reliable powerElectronic device loads, such as inverters,distort the current waveform. Mitsubishiselectronic breakers use a digital detectorto measure the currents effective valueand minimize overload tripping errors.This enables precise protection of thecircuit.Overload protection and safetyThe neutral-pole overload protection cir-cuit is standard with 4-wire electronicmoulded-case devices.It prevents burn-out when the neutral-poles load current is greater than thevoltage pole in a 3-phase 4 wire circuitwhich is prone to distorted third-harmoniccurrent flows.Coordinated protection frommultiple tripping characteristicsTime[s]Current [A]Current setting IrPre-alarmcurrent IPLoad currentInstantaneous trippingcurrent IIShort time-delayoperating time TSShort time-delay trippingcurrent ISLong time-delayoperating time TLHigh-voltage fuse allowableshort-time characteristicHighvoltageLowvoltageMCCBLoadL1L2L3NRated current InAlarmfunction monitors and anticipates interruptionsOur electronic moulded-case circuitbreakers feature a pre-alarmsystemasstandard. The pre-alarmoutputs an alarmbefore the circuit breaker trip is activated.When the load current exceeds the setpre-alarmcurrent, it outputs a pre-alarmsignal (froma solid-state relay) and lightsthe LED.The pre-alarmmodule (with contactoutput) is optional with electronicmolded-case and earth-leakage circuitbreakers.Improved protection against fluctua-tions in the load currentOur standard electronic trip relay offers anumber of outstanding benefits.The user has a choice of six differentparameters as tripping characteristics withthe multiple coordinated protectionmethod.Better protection can be obtainedbetween the high-voltage fuse, OCR andthe lowvoltage fuse.Portable tester facilitates checkingand maintenanceThe separately sold portable tester allowsthe user to check the four characteristics: 1. Long-delay tripping 2. Short-delay tripping 3. Instantaneous tripping 4. Pre-alarmcharacteristicsLEDs for load current, pre-alarmandover-current showthe operating status.NF400-SEW3PShort time-delayoperating time TSdPre-alarmcurrent IPInstantaneous tripping current IILong time-delayoperating time TLShort time-delay tripping current IS Current setting Ir7 MITSUBISHI ELECTRICINTRODUCTIONANDCONFIGURATIONINTRODUCTIONANDCONFIGURATION///Calculation and Selection Software MELSHORT2MELSHORT2 The NewCalculation Software forLow-Voltage SwitchgearsMELSHORT2 is a software package that provides all the functionsneeded for planning and dimensioning switchgear systems.Increasingly demanding technical specifications and accountabil-ity regulations are making switchgear configuration much morecritical than it used to be. In the past, software for calculating anddimensioning switchgear was helpful nowadays its absolutelyessential.Mitsubishi Electrics MELSHORT2 is a complete software packagethat provides all the functions needed for successful switchgearsystemconfiguration and layout. It supports all modern interna-tional electrical engineering standards and shines with simpleand reliable operation.The programcalculates the short-circuit levels and currents at allnecessary points for all switchgear components, including thepower supply transformer and circuit breakers, the emergencygenerators, the individual motor and capacitor group branch cir-cuits and all the other power distribution circuits, down to the lastcircuit breaker. This makes it possible to select the ideal breakerfor every task, for optimumperformance and cost-efficiency.MELSHORT2 has a comprehensive range of powerful, easy-to-usefunctions, including: Selective shutdown Backup protection Coordination with the main power supply systems Allowance for the start-up currents of electric motorsThese functions make it possible to optimise the configuration ofyour switchgear equipment for the specific requirements of yourapplications.The calculated results, the hardware model suggestions and thewiring diagramwith all the relevant values can be processed andused as documentation for the switchgear installation. Anotherwelcome extra is the free Internet update service.Specifications MELSHORT2Operating system MS Windows 95/98/NT4.0/2000Disk type CD-ROMArt. no. 129115Circuit diagramof the network to be calculated, withinput fieldDisplay of the trip curves of a circuit breaker inthe network8 MITSUBISHI ELECTRICINTRODUCTIONANDCONFIGURATION/// INTRODUCTIONANDCONFIGURATIONProduct Skeleton of AccessoriesMITSUBISHI ELECTRIC offers a wide range of accessories for theMoulded-case circuit breakers and Disconnectors to serve almostall variations of applications.Detailled information on request.1 Circuit Breaker see page 122 Relay unit RT (Thermal type) on request3 Relay unit RE (Electronic type) on request4 Solderless (Box) terminals see page 355 Rear connection studs see page 356 Insulating barriers (BA-F) see page 417 Small terminal covers (TC-S) see page 408 Large terminal covers (TC-L) see page 409 Rear terminal covers (BTC) see page 4010 Plug-in base (PM) see page 3511 Connections for Plug-in see page 3512 Mechanical interlock (MI) see page 4113 OFF Lock with 3 padlocks (HL) see page 3714 Handle lock device (LC, HLF, HLN, HLS) see page 3715 Variable-depth operating handle, V type see page 3616 Rotary operating handle, R type see page 3617 Electrical operating device (MDS) see page 3918 Alarmand Auxiliary switches (AL, AX) see page 2619 Under voltage trip device (UVT) see page 3020 Shunt trip device (SHT) see page 2811413121716R E S E TOF FTRIPPEDPUSH TO TRIPONAC100-240V50/60HzInstall and uninstall theaccessory in tripped position,not in ON or OFF positionSHTA240-2GSWRSC2 S2C1 S1SHT20D1 P1D3 P3D2 P2SOURCEHiLo1918ALAX-2GSWLSMITSUBISHIELECTRICAL95 c14 a96 b12 b98 a11 cAXALARMSWITCHA C AC DC DC125 V2 50V125 V25 0V5 A 3A0. 4 A0 .2A98ALa96ALb98ALcAUXILIARY SWITCHA C AC DC DC12 5V25 0V125 V25 0V5A 3A0.4 A0.2A11AXc12AXb14AXaPush to(MANU)NO-FUSE BREAKERNF250-SGWMSDBA-NF25GSWA0106MODELPushPullMODELSERIAL:Ui 690VCat.AIEC60947-2JIS C 8201-2Ue690VAC525VAC500VAC440VAC380/415VAC230VACMANUAUTORATED CURRENT250 AUimp 8kVEN60947-240CIcu/Ics8/8kA22/22kA30/30kA36/36kA36/36kA85/85kA50/60HzPush toOPEN(TRIP)ONMITSUBISHI ELECTRICONDis-chargeControl circuitvoltage should besupplied to P1and P2 terminals.P1 P2 S1 S2 S4MITSUBISHIPOWER SUPPLY MODULEMODEL MDSPSA240-SWCONTROLL CIRCUIT VOLTAGEAC100-240V/DC100-250VS 4O p e r a t i n g C i r c u i tS 2 P 2S 1 P 1P 1P 2S 1S 2S 4U cU cO NK 3K 2K 2K 1 K 1S W 1 K 3K 3 K 2 K 1P o w e rS u p p l yO F F15R E S E TO F FTRIPPEDPUSH TO TRIPON63 100 100 12 2 2.5 10 .06 .07 .10 .3 468 101214.1 .28 7 6 5 4 80 3.5 3 60 80PAL 70%50/60HzTTs TL Ii IsIr IpIi(X100A)Ir(A) TL(S) IS(xIr) TS(S) Ip(xIr)OVER MODELRE100 In 100A9 MITSUBISHI ELECTRICINTRODUCTIONANDCONFIGURATIONINTRODUCTIONANDCONFIGURATION///6 8 7 958 7 9456411111MITSUBISHIOFFONNO-FUSE BREAKERNF125-SGWIn A 125Ir 75-125AMODELPOLEUi690VCat.APUSH TOTRIPUimp 8kV3 PIEC60947-2JIS C 8201-2Ue690VAC525VAC500VAC440VAC380/415VAC230VAC300VACEN60947-240CIcu/Ics8/8kA22/22kA30/30kA36/36kA36/36kA85/85kA20/20kAMITSUBISHI ELECTRIC102PAL 70%50/60Hz (AC only)TTs TL Ii IsIrIpIi(X100A)Ir(A) TL(S) IS(xIr) TS(S) Ip(xIr)75 125 100 12 .06 .3 468 101214.1 .28090 100 60 80OVER MODELRE125 In 125A2 2.5 1087 6 5 4 3.5 3 .7.751.0.95 .85 .8 .9MODELRT125In 125A16050/60Hz40C Ir(A)Ir(x125A AC)Ii(DC)=1.3XIi(AC) 3P3E20025046 810Ir Ii3PAL 70%50/60Hz (AC only)TTs TL Ii IsIrIpIi(X100A)Ir(A) TL(S) IS(xIr) TS(S) Ip(xIr)75 125 100 12 .06 .3 468 101214.1 .28090 100 60 80OVER MODELRE125 In 125A2 2.5 1087 6 5 4 3.5 3 .7.751.0.95 .85 .8 .910 MITSUBISHI ELECTRICINTRODUCTIONANDCONFIGURATION/// INTRODUCTIONANDCONFIGURATIONType / Series WSS seriesNF32-SW NF63-SW NF125-SGWRT NF125-SGWRE NF160-SGWRT NF160-SGWRESseriesRated current In max.[A] 32 63 125* 125* 160* 160*Rated insulation voltage Ui[V] AC 600 600 690 690 690 690Number of poles 3 3 / 4 3 / 4 3 / 4 3 / 4 3 / 4Ratedbreakingcapacity [kA](Icu /Ics)IEC 947-2EN 60 947-2VDE 0660AC(50/60 Hz)690 V 8 / 8 8 / 8 8 / 8 8 / 8500 V 2.5 / 1 7.5 / 4 30 / 30 30 / 30 30 / 30 30 / 30440 V 2.5 / 1 7.5 / 4 36 / 36 36 / 36 36 / 36 36 / 36400 V 5 / 2 7.5 / 4 36 / 36 36 / 36 36 / 36 36 / 36230 V 7.5 / 4 15 / 8 85 / 85 85 / 85 85 / 85 85 / 85Dimensions WxHxD [mm] 75x130x68 75/100x130x68 105/140x165x86 105/140x165x86 105/140x165x86 105/140x165x86Type NF63-HW NF125-HGWRT NF125-HGWRE NF160-HGWRT NF160-HGWREHseriesRated current In max.[A] 63 125* 125* 160* 160*Rated insulation voltage Ui[V] 690 690 690 690 690Number of poles 3 / 4 3 / 4 3 / 4 3 / 4 3 / 4Ratedbreakingcapacity [kA](Icu /Ics)IEC 947-2EN 60 947-2VDE 0660AC(50/60 Hz)690 V 2.5 / 1 20 / 20 20 / 20 20 / 20 20 / 20500 V 7.5 / 4 50 / 50 50 / 50 50 / 50 50 / 50440 V 10 / 5 65 / 65 65 / 65 65 / 65 65 / 65400 V 10 / 5 75 / 75 75 / 75 75 / 75 75 / 75230 V 25 / 13 100 / 100 100 / 100 100 / 100 100 / 100Dimensions WxHxD [mm] 75/100x130x68 105/140x165x86 105/140x165x86 105/140x165x86 105/140x165x86Type NF125-RGWRTRseriesRated current In max.[A] 100Rated insulation voltage Ui[V] 690Number of poles 3Ratedbreakingcapacity [kA](Icu /Ics)IEC 947-2EN 60 947-2VDE 0660AC(50/60 Hz)690 V 25 / 25500 V 125 / 125440 V 125 / 125400 V 125 / 125230 V 125 / 125Dimensions WxHxD [mm] 105x240x86Type NF125-UGWRTUseriesRated current In max.[A] 100Rated insulation voltage Ui[V] 690Number of poles 3 / 4Ratedbreakingcapacity [kA](Icu /Ics)IEC 947-2EN 60 947-2VDE 0660AC(50/60 Hz)690 V 30 / 30500 V 200 / 200440 V 200 / 200400 V 200 / 200230 V 200 / 200Dimensions WxHxD [mm] 105/140x240x86Type DSN32-SW DSN63-SW DSN125-SGW DSN160-SGWDisconnectorsRated current In max.[A] 32 63 125 160Rated insulation voltage Ui[V] AC/DC 600 600 690 690Rated voltage Ue[V] AC (50/60 Hz) / DC 500 / 250 500 / 250 690 / 300 690 / 300Number of poles 3 3 / 4 3 / 4 3 / 4Max. switching current [A] (breaking) AC/DC 256 / 128 504 / 252 1000 / 500 1280 / 640Dimensions WxHxD 75x130x68 75/120x130x68 105/140x165x86 105/140x165x86DC on requestIn case of solderless terminal, interrupting capacity reduces. * adjustableModel Overview and Specifications11 MITSUBISHI ELECTRICINTRODUCTIONANDCONFIGURATIONINTRODUCTIONANDCONFIGURATION///WSS seriesNF250-SGWRT NF250-SGWRE NF400-SEW NF630-SEW NF800-SEW NF1000-SEW NF1250-SEW NF1600-SEW250* 250* 400* 630* 800* 1000* 1250* 1600*690 690 690 690 690 690 690 6903 / 4 3 / 4 3 / 4 3 / 4 3 / 4 3 / 4 3 / 4 3 / 48 / 8 8 / 8 10 / 1010 / 10 10 / 10 25 / 13 25 / 13 25 / 1330 / 30 30 / 30 30 / 3030 / 30 30 / 30 65 / 33 65 / 33 65 / 3336 / 36 36 / 36 42 / 4242 / 42 42 / 42 85 / 43 85 / 43 85 / 4336 / 36 36 / 36 50 / 5050 / 50 50 / 50 85 / 43 85 / 43 85 / 4385 / 85 85 / 85 85 / 8585 / 85 85 / 85 125 / 63 125 / 63 125 / 63105/140x165x86 105/140x165x86 140/185x257x103 210/280x275x103 210/280x275x103 210/280x406x140 210/280x406x140 210/280x406x140NF250-HGWRT NF250-HGWRE NF400-HEW NF630-HEW NF800-HEW250* 250* 400* 630* 800*690 690 690 690 6903 / 4 3 / 4 3 / 4 3 / 4 3 / 420 / 20 20 / 20 10 / 10 15 / 15 15 / 1550 / 50 50 / 50 50 / 50 50 / 50 50 / 5065 / 65 65 / 65 65 / 65 65 / 65 65 / 6575 / 75 75 / 75 70 / 70 70 / 70 70 / 70100 / 100 100 / 100 100 / 100 100 / 100 100 / 100105/140x165x86 105/140x165x86 140/185x257x103 210/280x275x103 210/280x275x103NF250-RGWRT NF400-REW NF630-REW NF800-REW225 400* 630* 800*690 690 690 6903 3 3 325 / 25 15 / 10 20 / 15 20 / 15125 / 125 70 / 35 70 / 35 70 / 35125 / 125 125 / 63 125 / 63 125 / 63125 / 125 125 / 63 125 / 63 125 / 63125 / 125 150 / 75 150 / 75 150 / 75105x240x86 140x257x103 210x275x103 210x275x103NF250-UGWRT NF400-UEW NF800-UEW225 400* 800*690 690 6903 / 4 3 / 4 3 / 430 / 30 35 / 35 35 / 35200 / 200 170 / 170 170 / 170200 / 200 200 / 200 200 / 200200 / 200 200 / 200 200 / 200200 / 200 200 / 200 200 / 200105/140x240x86 140/280x297/322x200 210/280x322x200DSN250-SGW DSN400-SW DSN630-SW DSN800-SW DSN1000-SW DSN1250-SW DSN1600-SW250 400 630 800 1000 1250 1600690 690 690 690 660 660 660690 / 300 690 / 250 690 / 250 690 / 250 660 / 250 660 / 250 660 / 2503 / 4 3 / 4 3 / 4 3 / 4 3 / 4 3 / 4 3 / 42000 / 1000 3200 / 1600 5040 / 2520 6400 / 3200 8000 / 14000 10000 / 5000 12800 / 6400105/140x165x86 140/185x257x103 210/280x275x103 210/280x275x103 210/280x406x140 210/280x406x140 210/280x406x140* adjustable12 MITSUBISHI ELECTRICCIRCUITBREAKERS/// CIRCUIT BREAKERSType (Reference for Order information on p. 22) NF32-SW (1) NF63-SW (2) NF63-HW (3) NF125-SGWRT (4) NF125-SGWRE (5)Frame (A) 32 63 63 125 125Rated current In[A]at ambient temperature40 C3, 4, 6, 10, 16, 20,25, 32Fixed3, 4, 6, 10, 16, 20,25, 32, 40, 50, 63Fixed10, 16, 20, 25, 32,40, 50, 63Fixed1625, 2540, 4063,63100, 80125Adjustable1632, 3263,63100, 75125AdjustableNumber of poles 3 3 / 4 3 / 4 3 / 4 3 / 4Rated insulation voltage Ui[V] AC 600 600 690 690 690Ratedbreakingcapacity [kA](Icu /Ics)IEC/EN 60947-2AC(50/60 Hz)690 V 2.5 / 1 8 / 8 8 / 8500 V 2.5 / 1 7.5 / 4 7.5 / 4 30 / 30 30 / 30440 V 2.5 / 1 7.5 / 4 10 / 5 36 / 36 36 / 36400 V 5 / 2 7.5 / 4 10 / 5 36 / 36 36 / 36230 V 7.5 /4 15 / 8 25 / 13 85 / 85 85 / 85DC 300 V 20 / 20Utilization category A A A A ARated impulse withstand voltage Uimp[kV] 6 6 6 8 8Pollution degree 2 2 2 3 3Reverse connection Suitable for isolation Dimensions [mm]a 75 75 / 100 75 / 100 105 / 140 105 / 140b 130 130 130 165 165c 68 68 68 86 86ca 90 90 90 110 110Weight [kg] 0.55 0.60 / 0.70 0.60 / 0.70 2.0 / 2.6 2.0 / 2.6Cassette-typeaccessoriesAlarmswitch (AL) Auxiliary switch (AX) Shunt trip (SHT) Undervol-tage tripNon-synchronousclosing (UVT-N) Synchronous closing (UVT-S) Accessoriesconnectionwith terminal block (SLT) with internal terminal type InstallationandconnectionFrontScrewterminal (standard) Solderless terminal Busbar terminal Rear (B) Plug-inRear (PM) Rear front IP 20with auto trip(PM-IP) Built-inaccessoriesPre-alarm-contact output(PAL) Overcurrent trip alarm(OAL) External operatinghandleDoor mounting (V) Mounted on breaker (R) Electrical operation device (MDS) Handle lock deviceHandle lock for usewith padlock(HL) (HL-S) Lock cover (LC) TerminalcoverLarge (TC-L) Small (TC-S) For rear connection (BTC) For plug-in (PTC) Mechanical interlock (MI) Insulating barrier Between phase (Standard) (BA-F) Adapter for IEC 35 mmrail Marine approvalfor 3 pole breakers LR, GL, BV, DNV, AB LR, GL, BV, DNV, AB LR, GL, BV, DNV, AB LR, GL, BV, DNV, AB LR, GL, BV, DNV, ABAutomatic tripping device Hydraulic-magnetic Hydraulic-magnetic Hydraulic-magnetic Thermal-magnetic ElectronicTrip button Equipped Equipped Equipped Equipped EquippedBoth PAL and OAL is not available. Only one specified.Others on request.On request.Use of 3- or 4-pole breaker for DC, see wiring diagramon the next page.Missing specifications accord. to IEC/EN 60947-2 on request.Specifications of Moulded-Case Circuit Breakers 3125 AabccaRateddataMechanicaldataExternalaccessoriesOthers13 MITSUBISHI ELECTRICCIRCUITBREAKERSCIRCUIT BREAKERS ///NF125-HGWRT (6) NF125-HGWRE (7) NF125-RGWRT (8) NF125-UGWRT (9)125 125 125 1251625, 2540, 4063,63100, 80125Adjustable1632, 3263,63100, 75-125Adjustable1625, 2540,4063, 63100Adjustable1625, 2540,4063, 63100Adjustable3 / 4 3 / 4 3 3 / 4690 690 690 69020 / 20 20 / 20 25 / 25 30 / 3050 / 50 50 / 50 125 / 125 200 / 20065 / 65 65 / 65 125 / 125 200 / 20075 / 75 75 / 75 125 / 125 200 / 200100 / 100 100 / 100 125 / 125 200 / 20040 / 40 A A A A8 8 8 83 3 3 3 105 / 140 105 / 140 105 105 / 140165 165 240 24086 86 86 86110 110 110 1102.0 / 2.6 2.0 / 2.6 3.1 3.1 / 3.9 / / LR, GL, BV, DNV, AB LR, GL, BV, DNV, AB LR, GL, BV, DNV, AB LR, GL, BV, DNV, ABThermal-magnetic Electronic Thermal-magnetic Thermal-magneticEquipped Equipped Equipped EquippedNLineLoad Load Line3-pole 4-poleUse of 3- and 4-polebreakers for DC14 MITSUBISHI ELECTRICCIRCUITBREAKERS/// CIRCUIT BREAKERSType (Reference for Order information on p. 23) NF160-SGWRT (10) NF160-SGWRE (11) NF160-HGWRT (12) NF160-HGWRE (13)Frame (A) 160 160 160 160Rated current In[A]at ambient temperature40 C125160Adjustable80160Adjustable125160Adjustable80160AdjustableNumber of poles 3 / 4 3 / 4 3 / 4 3 / 4Rated insulation voltage Ui[V] AC 690 690 690 690Ratedbreakingcapacity [kA](Icu /Ics)IEC/EN 60947-2AC(50/60 Hz)690 V 8 / 8 8 / 8 20 / 20 20 / 20500 V 30 / 30 30 / 30 50 / 50 50 / 50440 V 36 / 36 36 / 36 65 / 65 65 / 65400 V 36 / 36 36 / 36 75 / 75 75 / 75230 V 85 / 85 85 / 85 100 / 100 100 / 100DC 300 V 20 / 20 40 / 40Utilization category A A A ARated impulse withstand voltage Uimp[kV] 8 8 8 8Pollution degree 3 3 3 3Reverse connection Suitable for isolation Dimensions [mm]a 105 / 140 105 / 140 105 / 140 105 / 140b 165 165 165 165c 86 86 86 86ca 110 110 110 110Weight [kg] 2.0 / 2.6 2.0 / 2.6 2.0 / 2.6 2.0 / 2.6Cassette-typeaccessoriesAlarmswitch (AL) Auxiliary switch (AX) Shunt trip (SHT) Undervol-tage tripNon-synchronousclosing (UVT-N) Synchronous closing (UVT-S) Accessoriesconnectionwith terminal block (SLT) with internal terminal type InstallationandconnectionFrontScrewterminal (standard) Solderless terminal Busbar terminal Rear (B) Plug-inRear (PM) Rear front IP 20with auto trip(PM-IP) Built-inaccessoriesPre-alarm-contact output(PAL) Overcurrent trip alarm(OAL) External operatinghandleDoor mounting (V) Mounted on breaker (R) Electrical operation device (MDS) Handle lock deviceHandle lock for usewith padlock(HL) (HL-S) Lock cover (LC) TerminalcoverLarge (TC-L) Small (TC-S) For rear connection (BTC) For plug-in (PTC) Mechanical interlock (MI) Insulating barrier Between phase (Standard) (BA-F) Adapter for IEC 35 mmrail Marine approvalfor 3 pole breakers Automatic tripping device Thermal-magnetic Electronic Thermal-magnetic ElectronicTrip button Equipped Equipped Equipped EquippedBoth PAL and OAL is not available. Only one specified.Others on request.On request.Use of 3- or 4-pole breaker for DC, see wiring diagramon the next page.Missing specifications accord. to IEC/EN 60947-2 on request.Specifications of Moulded-Case Circuit Breakers 160250 AabccaRateddataMechanicaldataExternalaccessoriesOthers15 MITSUBISHI ELECTRICCIRCUITBREAKERSCIRCUIT BREAKERS ///NF250-SGWRT (14) NF250-SGWRE (15) NF250-HGWRT (16) NF250-HGWRE (17) NF250-RGWRT (18) NF250-UGWRT (19)250 250 250 250 250 250125160, 160250Adjustable125250Adjustable125160, 160250Adjustable125250Adjustable125160, 160225Adjustable125160, 160225Adjustable3 / 4 3 / 4 3 / 4 3 / 4 3 3 / 4690 690 690 690 690 6908 / 8 8 / 8 20 / 20 20 / 20 25 / 25 30 / 3030 / 30 30 / 30 50 / 50 50 / 50 125 / 125 200 / 20036 / 36 36 / 36 65 / 65 65 / 65 125 / 125 200 / 20036 / 36 36 / 36 75 / 75 75 / 75 125 / 125 200 / 20085 / 85 85 / 85 100 / 100 100 / 100 125 / 125 200 / 20020 / 20 40 / 40 A A A A A A8 8 8 8 8 83 3 3 3 3 3 105 / 140 105 / 140 105 / 140 105 / 140 105 105 / 140165 165 165 165 240 24086 86 86 86 86 86110 110 110 110 110 1102.0 / 2.6 2.0 / 2.6 2.0 / 2.6 2.0 / 2.6 3.1 3.1 / 3.9 / / LR, GL, BV, DNV, AB LR, GL, BV, DNV, AB LR, GL, BV, DNV, AB LR, GL, BV, DNV, AB LR, GL, BV, DNV, AB LR, GL, BV, DNV, ABThermal-magnetic Electronic Thermal-magnetic Electronic Thermal-magnetic Thermal-magneticEquipped Equipped Equipped Equipped Equipped EquippedNLineLoad Load Line3-pole 4-poleUse of 3- and 4-polebreakers for DC16 MITSUBISHI ELECTRICCIRCUITBREAKERS/// CIRCUIT BREAKERSType (Reference for Order information on p. 23) NF400-SEW (20) NF400-HEW (21) NF400-REW (22)Frame (A) 400 400 400Rated current In[A]at ambient temperature40 C200400Adjustable200400Adjustable200400AdjustableNumber of poles 3 / 4 3 / 4 3Rated insulation voltage Ui[V] AC 690 690 690Ratedbreakingcapacity [kA](Icu /Ics)IEC/EN 60947-2AC(50/60 Hz)690 V 10 / 10 (5 / 5)10 / 10 15 / 10500 V 30 / 30 (25 / 25)50 / 50 70 / 35440 V 42 / 42 (36 / 36)65 / 65 125 / 63400 V 50 / 50(36 / 36) 70 / 70 125 / 63230 V 85 / 85 (65 / 65)100 / 100 150 / 75Utilization category B B BRated short-time withstand current Icw[kA/s] 5 / 0.25 5 / 0.25 5 / 0.25Rated impulse withstand voltage Uimp[kV] 8 8 8Pollution degree 3 3 3Reverse connection Suitable for isolation Dimensions [mm]a 140 / 185 140 / 185 140b 257 257 257c 103 103 103ca 155 155 155Weight [kg] 6.0 / 7.8 6.0 / 7.8 6.0Cassette-typeaccessoriesAlarmswitch (AL) Auxiliary switch (AX) Shunt trip (SHT) Undervol-tage tripNon-synchronousclosing (UVT-N) Synchronous closing (UVT-S) Accessoriesconnectionwith terminal block (SLT) with internal terminal type InstallationandconnectionFront Busbar terminal (standard) Rear (B) Plug-in Rear (PM) Built-inaccessoriesPre-alarm-contact output (PAL) Trip indicator (TI) External operatinghandleDoor mounting (V) Mounted on breaker (R) Electrical operationdeviceSpring-charge type (MDS) Handle lock deviceHandle lock for usewith padlock(HL) (HL-S) TerminalcoverLarge (TC-L) For rear connection (BTC) Mechanical interlock (MI) Insulating barrier Between phase (Standard) (BA-F) Marine approvalfor 3 pole breakers LR, GL, BV, DNV, AB LR, GL, BV, AB LR, GL, BV, ABAutomatic tripping device Electronic Electronic ElectronicTrip button Equipped Equipped EquippedDC type on request.In case of solderless terminal, interrupting capacity reduces.On request.Others on request.Missing specifications accord. to IEC/EN 60947-2 on request.Specifications of Moulded-Case Circuit Breakers 400630 AabccaRateddataMechanicaldataExternalaccessoriesOthers17 MITSUBISHI ELECTRICCIRCUITBREAKERSCIRCUIT BREAKERS ///NF400-UEW (23) NF630-SEW (24) NF630-HEW (25) NF630-REW (26)400 630 630 630200400Adjustable300630Adjustable300630Adjustable300630Adjustable3 / 4 3 / 4 3 / 4 3690 690 690 69035 / 35 10 / 10 35 / 18 20 / 15170 / 170 30 / 30 50 / 50 70 / 35200 / 200 42 / 42 65 / 65 125 / 63200 / 200 50 / 50 70 / 70 125 / 63200 / 200 85 / 85 100 / 100 150 / 75B B B B5 / 0.25 7.6 / 0.25 7.6 / 0.25 7.6 / 0.258 8 8 83 3 3 3 140 / 280 140 / 185 140 / 185 140297 / 322 257 257 257200 103 103 103252 155 155 15516.7 / 26.1 6.5 / 8.3 6.5 / 8.3 6.5 / LR, GL, BV, AB LR, GL, BV, AB LR, GL, BV, AB LR, GL, BV, ABElectronic Electronic Electronic ElectronicEquipped Equipped Equipped Equipped18 MITSUBISHI ELECTRICCIRCUITBREAKERS/// CIRCUIT BREAKERSType (Reference for Order information on p. 23) NF800-SEW (27) NF800-HEW (28) NF800-REW (29)Frame (A) 800 800 800Rated current In[A]at ambient temperature40 C400800Adjustable400800Adjustable400800AdjustableNumber of poles 3 / 4 3 / 4 3Rated insulation voltage Ui[V] AC 690 690 690Ratedbreakingcapacity [kA](Icu /Ics)IEC/EN 60947-2AC(50/60 Hz)690 V 10 / 10 15 / 15 500 V 30 / 30 50 / 50 70 / 35440 V 42 / 42 65 / 65 125 / 63400 V 50 / 50 70 / 70 125 / 63230 V 85 / 85 100 / 100 150 / 75Utilization category B B BRated short-time withstand current Icw[kA/s] 9.6 / 0.25 9.6 / 0.25 9.6 / 0.25Rated impulse withstand voltage Uimp[kV] 8 8 8Pollution degree 3 3 3Reverse connection Suitable for isolation Dimensions [mm]a 210 / 280 210 / 280 210b 275 275 275c 103 103 103ca 155 155 155Weight [kg] 10.9 / 14.2 10.9 / 14.2 10.9Cassette-typeaccessoriesAlarmswitch (AL) Auxiliary switch (AX) Shunt trip (SHT) Undervol-tage tripNon-synchronousclosing (UVT-N) Synchronous closing (UVT-S) Accessoriesconnectionwith terminal block (SLT) with internal terminal type InstallationandconnectionFront Busbar terminal (Standard) Rear (B) Plug-in Rear (PM) Built-inaccessoriesPre-alarm-contact output (PAL) Trip indicator (TI) External operatinghandleDoor mounting (V) Mounted on breaker (R) Electrical operationdeviceSpring-charge type (MDS) Handle lock deviceHandle lock for usewith padlock(HL) (HL-S) TerminalcoverLarge (TC-L) For rear connection (BTC) Mechanical interlock (MI) Insulating barrier Between phase (Standard) (BA-F) Marine approvalfor 3 pole breakers LR, GL, BV, DNV, AB LR, GL, BV, AB LR, GL, BV, ABAutomatic tripping device Electronic Electronic ElectronicTrip button Equipped Equipped EquippedDC type on request.On request.Others on request.Assembly by factory.Missing Specifications accord. to IEC/EN 60947-2 on request.Specifications of Moulded-Case Circuit Breakers 8001600 AabccaRateddataMechanicaldataExternalaccessoriesOthers19 MITSUBISHI ELECTRICCIRCUITBREAKERSCIRCUIT BREAKERS ///NF800-UEW (30) NF1000-SEW (31) NF1250-SEW (32) NF1600-SEW (33)800 1000 1250 1600400800Adjustable5001000Adjustable6001250Adjustable8001600Adjustable3 / 4 3 / 4 3 / 4 3 / 4690 690 690 69035 / 35 25 / 13 25 / 13 25 / 13170 / 170 65 / 33 65 / 33 65 / 33200 / 200 85 / 43 85 / 43 85 / 43200 / 200 85 / 43 85 / 43 85 / 43200 / 200 125 / 63 125 / 63 125 / 63B B B B9.6 / 0.25 20 / 0.3 20 / 0.3 20 / 0.38 8 8 83 3 3 3 210 / 280 210 / 280 210 / 280 210 / 280322 406 406 406200 140 140 140252 190 190 19027.6 / 33.7 23.5 / 30.7 23.5 / 30.7 34.5 / 41.2 LR, GL, AB LR, GL, AB Electronic Electronic Electronic ElectronicEquipped Equipped Equipped Equipped20 MITSUBISHI ELECTRICCIRCUITBREAKERS/// CIRCUIT BREAKERSSpecifications of Disconnectors DSN, IEC 60947-3, EN 60947-3Type (Reference for Order information on p. 23) DSN32-SW (34) DSN63-SW (35) DSN125-SGW (36) DSN160-SGW (37) DSN250-SGW (38)Rated current In[A] 40 C 32 63 125 160 250Number of poles 3 3 / 4 3 / 4 3 / 4 3 / 4Rated insulation voltage Ui[V]AC 600 600 600 690 690DC 250 250 250 250 250Rated voltage Ue[V]AC 500 600 690 690 690DC 250 250 300 300 300Rated impulse withstand voltage Uimp [kV] kV 6 6 8 8 8Pollution degree 2 2 2 2 2Utilization category AC-23A, DC-23A AC-23A, DC-23A AC-23A, DC-23A AC-23A, DC-23A AC-23A, DC-23AMaking andbraking currentMaking cur-rentAC / DC A 320 / 128 630 / 252 1250 / 500 1600 / 640 2500 / 1000cycles 5 5 3 / 5 3 / 5 3 / 5Breaking cur-rentAC / DC A 256 / 128 504 / 252 1000 / 500 1280 / 640 2000 / 1000cycles 5 5 3 / 5 3 / 5 3 / 5OperationalperformanceWithout current 10000 10000 50000 40000 25000With current (440 V / 690 V) 6000 / 6000 / 30000 / 1000 20000 / 1000 10000 / 1000Short-time withstand current Icw1 s A 1000 1000 2000 3000 4000Short-circuit making capacity Icm1 s A 1500 1500 3000 4000 6000Max. switching currentAC / DC A 192 / 80 378 / 157.5 750 / 312.5 960 / 400 1500 / 625cycles 12 12 12 12 12Suitable for isolation Dimensions [mm]a 75 75 / 100 75 / 100 90 / 120 105 / 140b 130 130 165 165 165c 68 68 68 68 68ca 90 90 110 110 110Weight [kg] 0.55 0.60 2.0 / 2.6 2.0 / 2.6 2.0 / 2.6Cassette-typeaccessoriesAlarmswitch (AL) Auxiliary switch (AX) Shunt trip (SHT) Undervoltage trip (UVT) Accessoriesconnectionwith terminal block (SLT) with internal terminal type InstallationandconnectionFrontScrewterminal Solderless terminal Busbar terminal Rear (B) Plug-inRear (PM) Rear front IP 20with auto trip(PM-IP) External operatinghandleDoor mounting (V) Mounted on breaker (R) Electrical operation device (MDS) Handle lock deviceHandle lock for usewith padlock(HL) (HL-S) Lock cover (LC) TerminalcoverLarge (TC-L) Small (TC-S) / / For rear connection (BTC) / / Mechanical interlock (MI) Insulating barrier Between phase (Standard) (BA-F) Adapter for IEC 35 mmrail Corresponding type of circuit breaker NF32-SW NF63-SW NF125-SGW NF160-SGW NF250-SGWThis performance is accordance with IEC60947-2 clause 7.2.4.1.On request.Standard.Assembly by factory.TC-N.Missing specifications accord. to IEC/EN 60947-2 on request.abccaRateddataMechanicaldataExternalaccessories21 MITSUBISHI ELECTRICCIRCUITBREAKERSCIRCUIT BREAKERS ///DSN400-SW (39) DSN630-SW (40) DSN800-SW (41) DSN1000-SW (42) DSN1250-SW (43) DSN1600-SW (44)400 630 800 1000 1250 16003 / 4 3 / 4 3 / 4 3 / 4 3 / 4 3 / 4690 690 690 690 690 690250 250 250 250 250 250690 690 690 690 690 690250 250 250 250 250 2508 8 8 8 8 83 3 3 3 3 3AC-23A, DC-23A AC-23A, DC-23A AC-23A, DC-23A AC-23A, DC-23A AC-23A, DC-23A AC-23A, DC-23A4000 / 1600 6300 / 2520 8000 / 3200 10000 / 4000 12500 / 5000 16000 / 64003 / 5 3 / 5 3 / 5 3 / 5 3 / 5 3 / 53200 / 1600 5040 / 2520 6400 / 3200 8000 / 4000 10000 / 5000 12800 / 64003 / 5 3 / 5 3 / 5 3 / 5 3 / 5 3 / 54000 4000 2500 2500 2500 25001000 1000 500 500 500 5006000 8000 10000 12000 12000 1600010200 13600 17000 24000 24000 320002400 / 1000 3780 / 1575 4800 / 2000 6000 / 2500 7500 / 3125 9600 / 400012 12 12 12 12 12 140 / 185 210 / 280 210 / 280 210 / 280 210 / 280 210 / 280257 275 275 406 406 406103 103 103 140 140 140155 155 155 190 190 1905.7 / 7.5 8.5 / 12.5 10.9 / 14.2 23.0 / 30.2 23.0 / 30.2 34.0 / 40.7 NF400-SEW NF630-SEW NF800-SEW NF1000-SEW NF1250-SEW NF1600-SEW22 MITSUBISHI ELECTRICCIRCUITBREAKERS/// CIRCUIT BREAKERSOrder Information for Moulded-Case Circuit Breakers 3125 ARef.Type Rated current (In)Art. no.3 pole typeArt. no.4 pole typeS series with hydraulic-magnetic tripping device, fixed, AC1 NF32-SW 3 A 204474 4 A 204475 6 A 204477 10 A 204478 16 A 204480 20 A 204481 25 A 204482 32 A 204484 2 NF63-SW 3 A 204486 2045014 A 204487 2045026 A 204489 20450410 A 204490 20450516 A 204492 20450720 A 204493 20450825 A 204494 20450932 A 204496 20451140 A 204497 20451250 A 204498 20451363 A 204500 204515H series with hydraulic-magnetic tripping device, fixed, AC3 NF63-HW 10 A 204516 20452716 A 204518 20452920 A 204519 20453025 A 204520 20453132 A 204522 20453340 A 204523 20453450 A 204524 20453563 A 204526 204537Ref.Type Rated current (In)Art. no.3 pole typeArt. no.4 pole typeS series with thermal-magnetic tripping device, AC, DC4 NF125-SGWRT 1625 A 204540 2045452540 A 204541 2045464063 A 204542 20454763100 A 204543 20454880125 A 204544 204549S series with electronic tripping device, adjustable, AC5 NF125-SGWRE 1632 A 204550 2045543263 A 204551 20455563100 A 204552 20455675125 A 204553 204557H series with thermal-magnetic tripping device, adjustable, AC, DC6 NF125-HGWRT 1625 A 204558 2045632540 A 204559 2045644063 A 204560 20456563100 A 204561 20456680125 A 204562 204567H series with electronic tripping device, AC7 NF125-HGWRE 1632A 204568 2045723263A 204569 20457363100A 204570 20457475125A 204571 204575R series with thermal-magnetic tripping device, adjustable, AC8 NF125-RGWRT 1625 A 204576 2540 A 204577 4063 A 204578 63100 A 204579 U series with thermal-magnetic tripping device, adjustable, AC9 NF125-UGWRT 1625 A 204580 2045842540 A 204581 2045854063 A 204582 20458663100 A 204583 204587Reference to breaker specifications on p. 12ff.23 MITSUBISHI ELECTRICCIRCUITBREAKERSCIRCUIT BREAKERS ///Order Information for DisconnectorsDSN series 321600 AOrder Information for Moulded-Case Circuit Breakers 400800 AReference to breaker specifications on p. 12ff.Ref.Type Rated current (In)Art. no.3 pole typeArt. no.4 pole typeS series with thermal-magnetic tripping device, AC, DC10 NF160-SGWRT 125160 A 204591 204592S series with electronic tripping device, AC11 NF160-SGWRE 80160 A 204593 204594H series with thermal-magnetic tripping device, AC, DC12 NF160-HGWRT 125160A 204596 204597H series with electronic tripping device, adjustable, AC13 NF160-HGWRE 80160 A 204598 204599S series with thermal-magnetic tripping device, adjustable, AC, DC14 NF250-SGWRT 125160 A 212124 212125160250 A 204602 204603S series with electronic tripping device, adjustable, AC15 NF250-SGWRE 125250 A 204604 204605Ref.Type Rated current (In)Art. no.3 pole typeArt. no.4 pole typeH series with thermal-magnetic tripping device, adjustable, AC, DC16 NF250-HGWRT 125160 A 212126 212127160250 A 204606 204607H series with electronic tripping device, adjustable, AC17 NF250-HGWRE 125250 A 204608 204609R series with thermal-magnetic tripping device, adjustable, AC18 NF250-RGWRT 160225 A 204610 U series with thermal-magnetic tripping device, adjustable, AC19 NF250-UGWRT 125160 A 204611 204613160225 A 204612 204614Order Information for Moulded-Case Circuit Breakers10001600 AOrder Information for Moulded-Case Circuit Breakers 160250 ARef.Type Rated current (In)Art. no.3 pole typeArt. no.4 pole typeS series with electronic tripping device, adjustable, AC20 NF400-SEW 200400A 204780 20478124 NF630-SEW 300630A 204789 20479037 NF800-SEW 400800A 204797 204798H series with electronic tripping device, adjustable, AC21 NF400-HEW 200400A 204782 20478325 NF630-HEW 300630A 204791 20479228 NF800-HEW 400800A 204799 204800Ref.Type Rated current (In)Art. no.3 pole typeArt. no.4 pole typeR series with electronic tripping device, adjustable, AC22 NF400-REW 200400A 204784 26 NF630-REW 300630A 204793 29 NF800-REW 400800A 204801 U series with electronic tripping device, adjustable, AC23 NF400-UEW 200400A 204785 20478630 NF800-UEW 400800 A 204802 204803Ref.Type Rated current (In)Art. no.3 pole typeArt. no.4 pole typeSS/UR series with electronic tripping device, adjustable, AC31 NF1000-SEW 5001000 A 204810 20481132 NF1250-SEW 6001250 A 204812 20481333 NF1600-SEW 8001600 A 204814 204815Ref.Type Rated current (In)Art. no.3 pole typeArt. no.4 pole typeDisconnectors (no tripping device)34 DSN32-SW 32 A 204473 35 DSN63-SW 63 A 204485 20481736 DSN125-SGW 125 A 204538 20453937 DSN160-SGW 160 A 204588 20458938 DSN250-SGW 250 A 204600 20460139 DSN400-SW 400 A 204778 20477940 DSN630-SW 630 A 204787 20478841 DSN800-SW 800 A 204794 20479542 DSN1000-SW 1000 A 204804 20480543 DSN1250-SW 1250 A 204806 20480744 DSN1600-SW 1600 A 204808 20480924 MITSUBISHI ELECTRICINTERNALACCESSORIES/// INTERNAL ACCESSORIES63 100 100 12 22.510 .06.07 .10.3 468 101214.1 .2876 5 4 80 3.5360 80PAL 70%50/60HzTTs TL IiIsIrIpIi(X100A)Ir(A) TL(S) IS(xIr) TS(S) Ip(xIr)OVER MODELRE100 In 100AAC100-240V50/60HzInstall and uninstall theaccessory in tripped position,not in ON or OFF positionSHTA240-2GSWRSALAX-2GSWLSMITSUBISHIELECTRICAL95 c14 a96 b12 b98 a11 cAXALARMSWITCHACACDCDC125V250V125V250V5A3A0.4A0.2A98ALa96ALb98ALcAUXILIARYSWITCHACACDCDC125V250V125V250V5A3A0.4A0.2A11AXc12AXb14AXaShunt trip (SHT)Provides for tripping froma remote loca-tion. Thecontrol voltagerangeis 70100%of rated voltage.The shunt trip enables an MCCB to be usedin combination with an ELR. Lead-wireterminalblock(SLT)The terminal blockis used for bringingout the connectionsof the internalaccessories.The cassette typeaccessories are alsoavailable as internalterminal type with-out terminal block.The connectioncables are leadout of the breakerhousing in line-sidedirection. So it ispossible to mountseveral breakerseasy side-by-sidein a row.Internal AccessoriesModular cassette type accessoriesThe newarrangement and design ofpluggable accessories such as indicatorand auxiliary contacts allows you tomodify the circuit in a way that saves timeand space at any time, evenwhenbuilt inandready for operation.The presence of separate circuit chambersmakes the systemeven safer.Thus cassette type accessories ensureflexibility when upgrading circuits.The cassette type accessories are availablein several versions and fit for breaker seriesfrom32 A up to 800 A: alarmswitch (AL) auxiliary switch (AX) alarmand auxiliary switch (AL+AX) shunt trip device (SHT) undervoltage trip device (UVT)with lead-wire terminal block as standard.In addition you can choose the lead-wireversion or the internal terminal type as anoption.Alarmswitch (AL)Provides for indication that the MCCBhas tripped.Auxilliary switch (AX)Provides for indication of whether thebreaker is ONor OFF.For the breakers of the Super Series, 1000 A up to 1600 A, please contact your Distributor.Lead-wire terminal blockExample: ALAXInternal terminal typeExample: SHTUndervoltage trip (UVT)The tripping voltage is 3570 %of therated voltage. When the voltage recov-ers toat least 85 %, the breaker can bemanually closed or reset.Provides for electrical interlock, and isused where electrical machines needto be protected against voltage drop.25 MITSUBISHI ELECTRICINTERNALACCESSORIESINTERNAL ACCESSORIES ///Lead-Wire Terminal Block (SLT)ALAX-2GSWLSMITSUBISHIELECTRICAL95 c14 a96 b12 b98 a11 cAXALARMSWITCHACACDCDC125V250V125V250V5A3A0.4A0.2A98ALa96ALb98ALcAUXILIARYSWITCHACACDCDC125V250V125V250V5A3A0.4A0.2A11AXc12AXb14AXaApplicationAll cassette-type accessories areequipped with the Lead-wire terminalblock SLT as standard.The terminal cover for the lead-wireterminals is available for the safety oflive parts.It is available for front connection type,rear connection type and plug-In type. Correspondent terminals are notnecessary. Uneven arrangement of terminalscrews is adopted for easier wiring. Tightening check of a terminal screwis easy. Terminal cover of a terminal block isstandard equipment (co-packed).Overview of Internal AccessoriesCassette-type internal accessory Function Catalogue referenceAL (Alarmswitch) The alarmswitch AL indicates that the breaker has tripped. page 26AX (Auxiliary switch) The auxiliary switch AX indicates whether the breaker is ON or OFF. page 26SHT (Shunt trip)The shunt trip SHT trips the breaker automatically by remote. A cut-off switch is integrated.The allowable tripping voltage is 70%to 110%of the rated voltage for both AC and DC.page 28UVT (Undervoltage trip)The undervoltage trip UVT trips the breaker automatically when the voltage drops. The tripping voltage is 35%to 70%of therated voltage. When the voltage recovers to 85%of the rated voltage or above, the UVT can be reset and the breaker closed.page 30Cassette-type accessoryExample:ALAX, also for SHT, UVTInternal Terminal Type for Direct Connection96ALb98ALaAL-2GSWNMITSUBISHIELECTRICExample:AL, also for SHT, UVTApplicationOptional the cassette-type accessoriesare available as internal terminal typewithout terminal block.The control wires can be connected tothe integrated screwterminals and canbe lead out of the breaker housing inline-side direction. Quick install and de-install of the inter-nal accessories is possible withoutdemounting the breaker. Mounting of several breakersside-by-side in a rowis possible. Thus the screwterminals for controlwires are inside of the breaker hous-ing, no special terminal cover for thescrewterminals is necessary.Lead-wire terminal block SLTwith screwterminalsScrewterminalsConnection of the Control WiresFor the connectionof the control wiresMITSUBISHI ELECTRICoffers you twoways: Lead-wire terminal block (SLT) Internal terminal type for direct connection.26 MITSUBISHI ELECTRICINTERNALACCESSORIES/// INTERNAL ACCESSORIESAlarmswitch (AL) operationMain MCCB conditions AlarmcontactsOFF or ONALa 98 (open)ALc 95 (DC+)ALb 96 (closed)TripALa 98 (closed)ALc 95 (DC+)ALb 96 (open)When DC use, polarity must be considered.Auxiliary switch (AX) operationMain MCCB conditions Auxiliary contactsOFF or TripAXa 14 (open)AXc 11 (DC+)AXb 12 (closed)ONAXa 14 (closed)AXc 11 (DC+)AXb 12 (open)Switching OperationAL, AX switching capacitiesType of Micro-switch for Voltage (V AC) Resistive loads (A) Inductive load (A) Voltage (V DC)Resistive loads (A) Inductive load (A)AL/AX/ALAX-058460 250 0.2 0.2250 3 2 125 0.4 0.4125 5 3 30 4 3AL/AX/ALAX-10460 5 2 250 0.3 0.3250 10 10 125 0.6 0.6125 10 10 30 10 6When DC use, polarity must be considered.Alarm Switch and Auxiliary Switch(Mounted on left side)ApplicationThe alarmswitch AL indicates that thebreaker has tripped.The auxiliary switch AX indicates whetherthe breaker is ONor OFF.The alarmand auxiliary switch ALAX is acombination of the alarmswitch AL andthe auxiliary switch AX in one housing. AL, AX and ALAX standard types are forleft-side mounting and equipped withlead-wire terminal block SLT. Internal terminal type is also available. Please specify, if right-side mountedtype or type with flying leads is needed.Contact plans121114969598(1 W) (1 W)50/6Ir(A) TL(S) IS(xIr)MODELRE100 In 1014 a12 b11 cAXAUXILIARYSWITCHACACDCDC125V250V125V250V5A3A0.4A0.2A11AXc12AXb14AXa63 100 100 12 22.510 .876 5 480 3.5360 80Figure shows Lead-wire terminal block type (SLT).50/60MODELRE100 In 10Ir(A) TL(S) IS(xIr)63 100 100 12 22.510 .0876 5 480 3.5360 80Figure shows Internal terminal type.Alarmswitch AL Auxiliary switch AX27 MITSUBISHI ELECTRICINTERNALACCESSORIESINTERNAL ACCESSORIES ///Type Contacts Breaker type Mounted on Art. no.Alarm switch AL with lead-wire terminal block SLTAL-05SWLS 1 W NF/DSN3263Left side146379AL-2GSWLS 1 W NF/DSN125250 139505AL-4SWLS 1 WNF/DSN400800205763AL2-4SWLS 2 W 205764AL3-8SWLS 3 W NF/DSN800 205765AL-10SWL 1 W NF/DSN10001600 205766Alarm switch AL for direct connectionAL-2GSWN 1 W+1 W NF/DSN125250 Left side 139508Auxiliary switch AX with lead-wire terminal block SLTAX-05SWLS 1 WNF/DSN3263Left side146380AX2-05SWLS 2 W 146382AX-2GSWLS 1 WNF/DSN125250139504AX2-2GSWLS 2 W 139506AX-4SWLS 1 WNF/DSN400800205767AX2-4SWLS 2 W 205768AX3-8SWLS 3 WNF/DSN800NF400-UEW4P205769AX4-8SWLS 4 W 205770AX-10SWLS 1 WNF/DSN10001600205771AX2-10SWLS 2 W 205772AX3-10SWLS 3 W 205773Auxiliary switch AX for direct connectionAX-2GSWN 1 WNF/DSN125250 Left side139507AX2-2GSWLN 2 W 139510TypeContactsAL AXBreaker type Mounted on Art. no.Alarm switch and Auxiliary switch ALAX with lead-wire terminal block SLTALAX-05SWLS 1 W+1 W NF/DSN3263Left side146381ALAX-2GSWLS 1 W+1 W NF/DSN125250 137510ALAX-4SWLS 1 W+1 WNF/DSN400800NF400-UEW4P205774AL2AX2-4SWLS 2 W+2 W 205775ALAX-10SWL 1 W+1 WNF/DSN10001600205776AL1AX2-10SWL 1 W+2 W 205777Alarm switch and Auxiliary switch ALAX for direct connectionALAX-2GSWN 1 W+1 W NF/DSN125250 Left side 139509Order Information for Alarm Switch and Auxiliary Switch28 MITSUBISHI ELECTRICINTERNALACCESSORIES/// INTERNAL ACCESSORIESShunt Trip Device SHTApplicationThe shunt trip device SHT trips the breakerautomatically by remote. A cut-off switchis integrated.The allowable tripping voltage range is70%to 110%of the rated voltage for bothAC and DC.The SHT is mounted on the right side ofthe breaker and equipped with lead-wireterminal block SLT as standard.Please specify, if left-side mounted type ortype with flying leads is needed (optionalavailable).Please consider, the shunt trip device SHTfor 3-pole and 4-pole breakers is differentin the length of wires based on the outlinedimension of the breaker.Coil ratingsMCCB typeCut-off switch Voltage (V)InputOperating time(msec)AC (VA) DC (W)NF32-SWNF63-SWNF63-HWEquippedAC 2448AC 100240AC 380550(50 / 60 Hz)DC 1001251205015NF125-SGWRT/RENF125-HGWRT/RENF125-RGWRT/UGWRTNF160-SGWRT/RENF160-HGWRT/RENF250-SGWRT/RENF250-HGWRT/RENF250-RGWRT/UGWRTEquipped 60NF400-SEW/ HEW/ REW/ UEWNF630-SEW/ HEW/ REWNF800-CEW/ SEW/ HEW/ REW/ UEWEquippedAC 2448 / DC 2448AC 100450 / DC 100200AC 380550(50 / 60 Hz)100 V: 20200 V: 50330 V: 120450 V: 170100 V: 10200 V: 35515NF1000-SEWNF1250-SEWNF1600-SEWEquippedAC 100120AC 200240AC 380450(50 / 60Hz)DC 100200 70 715Also for DSN types.Other voltages on requestFor the SHT operating power capacity, any voltage drop in the input electric power must not be belowthe allowable operating voltage range.The operating time includes all the time up to the moment the main contact of the breaker disconnects after a voltage has been applied to the shunt trip devices.C1C2SHTContact planWith cut-off switchC2S2C1S1SHTPAL 70%50/60HzTTsTLIiIsIrIpIi(X100A)IS(xIr) TS(S)Ip(xIr)2510 .06.07 .10.3 468 101214.1 .2876 5 43.53OVER00 In 100AAC100-240V50/60HzInstall and uninstall theaccessory in tripped position,not in ON or OFF positionSHTA240-2GSWRSFigure shows Lead-wire terminal block type (SLT). Figure shows Internal terminal type.PAL 70%50/60HzTTsTLIiIsIrIpIi(X100A)IS(xIr) TS(S)Ip(xIr)2510 .06.07 .10.3 468 101214.1 .2876 5 43.53OVER00 In 100AAC100-240V50/60HzInstall and uninstall theaccessory in tripped position,not in ON or OFF positionSHTA240-2GSWRS29 MITSUBISHI ELECTRICINTERNALACCESSORIESINTERNAL ACCESSORIES ///With lead-wire terminal block SLT, mounted on right-sideFor 3-pole breaker For 4-pole breaker Rated voltageType Breaker type Art. no. Type Breaker type Art. no.SHTA048-05SWRSNF/DSN3263146383 SHTA048-05SWRFSNF/DSN3263146384 AC 2448 VSHTA240-05SWRS 146385 SHTA240-05SWRFS 146386 AC 100240 VSHTA550-05SWRS 146387 SHTA550-05SWRFS 146388 AC 380550 VSHTD012-05SWRS 146389 SHTD012-05SWRFS 146390 DC 12 VSHTD036-05SWRS 146391 SHTD036-05SWRFS 146392 DC 2436 VSHTD048-05SWRS 146393 SHTD048-05SWRFS 146394 DC 3648 VSHTD125-05SWRS 146395 SHTD125-05SWRFS 146396 DC100125 VSHTD250-05SWRS 146397 SHTD250-05SWRFS 146398 DC220250 VSHTA048-2GSWRSNF/DSN125250139513 SHTA048-2GSWRFSNF/DSN125250139514 AC 2448 VSHTA240-2GSWRS 139515 SHTA240-2GSWRFS 139516 AC 100240 VSHTA550-2GSWRS 139517 SHTA550-2GSWRFS 139518 AC 380550 VSHTD012-2GSWRS 139519 SHTD012-2GSWRFS 139520 DC 12 VSHTD036-2GSWRS 139521 SHTD036-2GSWRFS 139522 DC 2436 VSHTD048-2GSWRS 139523 SHTD048-2GSWRFS 139524 DC 3648 VSHTD125-2GSWRS 139525 SHTD125-2GSWRFS 139526 DC100125 VSHTD250-2GSWRS 139527 SHTD250-2GSWRFS 139528 DC220250 VSHT-4SWRSNF/DSN400800205778 SHT-4SWRFSNF/DSN400630205779 AC 100450 V / DC 100200 VSHT48-4SWRS 205780 SHT48-4SWRFS 205781 AC 2448 V / DC 2448 VSHTA550-4SWRS 205782 SHTA550-4SWRFS 205783 AC 380550 V SHT-8SWRFSNF/DSN800NF400-UEW4P205784 AC 100450 V / DC100200 VSHT48-8SWRFS 205785 AC 2448 V / DC 2448 VSHTA550-8SWRFS 205786 AC 380550 VSHTA120-10SWRSNF/DSN10001600205787 SHTA120-10SWRFSNF/DSN10001600205788 AC 100120 V, 50/60 HzSHTA240-10SWRS 205789 SHTA240-10SWRFS 205790 AC 200240 V, 50/60 HzSHTA450-10SWRS 205791 SHTA450-10SWRFS 205792 AC 380450 V, 50/60 HzSHTD024-10SWRS 205793 SHTD024-10SWRFS 205794 DC 24 VSHTD110-10SWRS 205795 SHTD110-10SWRFS 205796 DC 110 VFor direct connection, mounted on right-sideFor 3-/4-pole breakerType Breaker type Rated voltage Art. no.SHTA048-2GSWRNNF/DSN125250AC 2448 V 139529SHTA240-2GSWRN AC 100240 V 139530SHTA550-2GSWRN AC 380550 V 139531SHTD012-2GSWRN DC 12 V 139532SHTD036-2GSWRN DC 2436 V 139533SHTD048-2GSWRN DC 3648 V 139534SHTD125-2GSWRN DC 100125 V 139535SHTD250-2GSWRN DC 220250 V 139536Order Information for Shunt Trip Devices SHT30 MITSUBISHI ELECTRICINTERNALACCESSORIES/// INTERNAL ACCESSORIESUndervoltage Tripping Device UVTD1P1D3P3D2P2SOURCEHiLoInstall and uninstall theaccessory in tripped position,not in ON or OFF positionUVTS-2GSWRPAL 70%50/60HzTTsTLIiIsIrIp OVERIn 100AIi(X100A)xIr) TS(S)Ip(xIr)10 .06.07 .10.3 468 101214.1 .2876 5ApplicationThe undervoltage tripping device UVTtrips the breaker automatically when thevoltage drops. The tripping voltage is 35%to 70%ofthe rated voltage. When thevoltage recovers to 85%ofthe rated volt-age or above, the UVT can be reset and thebreaker closed.The UVT is mounted on the right side ofthe breaker and equipped with lead-wireterminal block SLT as standard.Please specify, if left-side mounted type ortype with flying leads is needed.Please consider, the undervoltage trip UVTfor 3-pole and 4-pole breaker is different inthe length of wires based on the outlinedimension of the breaker.Coil ratingsBreaker typeFor synchro-nousclosingVoltage (V)StandardInput (VA)Operating time(msec)Making/breaking dataBreaker OFF Breaker ONNF32-SWNF63-SWNF125-SGWRT/RENF125-HGWRT/RENF125-RGWRT/UGWRTNF160-SGWRT/RENF160-HGWRT/RENF250-SGWRT/RENF250-HGWRT/RENF250-RGWRT/UGWRTAC 100120AC 200240AC 220240AC 380450AC 400440(50 / 60 Hz)DC 24, DC 1105303570 %UNmin. 85 %UNNF400-SEW/ HEW/ REW/ UEWNF630-SEW/ HEW/ REWNF800-CEW/ SEW/ HEW/ REW/ UEWAC 100110/120130AC 200220/230250AC 380415/440480(50 / 60 Hz)DC100/110530(Instantaneous type)NF1000-SEWNF1250-SEWNF1600-SEWAC 100120/200240/380450AC 200250/380450/460550(50 / 60 Hz)535(Time delay type with3 voltage inputs)Also for DSN types.Other voltages on request.The operating time is the time from the start of operating the breaker since the undervoltage trip went from voltage to no-voltage condition.On request, please see page 31.UVTs with Time delay on request.MITSUBISHIOFFJ2J1D2 D2D1 D1J1J2Contact planPower control voltageBreakerUVT voltage control moduleInstall and uninstall theaccessory in tripped position,not in ON or OFF positionUVTS-2GSWRPAL 70%50/60HzTTsTLIiIsIrIp OVERIn 100AIi(X100A)Ir) TS(S)Ip(xIr)10 .06.07 .10.3 468 101214.1 .2876Figure shows Lead-wire terminal block type (SLT). Figure shows Internal terminal type.31 MITSUBISHI ELECTRICINTERNALACCESSORIESINTERNAL ACCESSORIES ///Breaker typeNo. ofPolesRated voltagesAC 24 / 48 VAC 100110 V /AC 120130 VAC 200220 V /AC 230250 VAC 380415 V /AC 440480 VAC 500550 V /AC 600 VDC 24 / 48 V DC 100 / 110 V DC 110 / 125 VInstantaneous trip type, with lead-wire terminal block SLTNF/DSN32633 UVTNA048-05SWRS UVTNA130-05SWRS UVTNA250-05SWRS UVTNA480-05SWRS UVTNA600-05SWRS UVTND048-05SWRS UVTND110-05SWRS UVTND125-05SWRS4 UVTNA048-05SWRFS UVTNA130-05SWRFS UVTNA250-05SWRFS UVTNA480-05SWRFS UVTNA600-05SWRFS UVTND048-05SWRFS UVTND110-05SWRFS UVTND125-05SWRFSNF/DSN1252503 UVTSA048-2GSWRS UVTSA130-2GSWRS UVTSA250-2GSWRS UVTSA480-2GSWRS UVTSA600-2GSWRS UVTSD048-2GSWRS UVTSD110-2GSWRS UVTSD125-2GSWRS4 UVTSA048-2GSWRFS UVTSA130-2GSWRFS UVTSA250-2GSWRFS UVTSA480-2GSWRFS UVTSA600-2GSWRFS UVTSD048-2GSWRFS UVTSD110-2GSWRFS UVTSD125-2GSWRFSInstantaneous trip type, for direct connectionNF/DSN125250 3/4 UVTSA048-2GSWRN UVTSA130-2GSWRN UVTSA250-2GSWRN UVTSA480-2GSWRN UVTSA600-2GSWRN UVTSD048-2GSWRN UVTSD110-2GSWRN UVTSD125-2GSWRNBreaker typeNo. ofPolesRated voltagesAC 100110 V /AC 120130 VAC 200220 V /AC 230250 VAC 380415 V /AC 440480 VDC 24 / 48 V DC 100 / 110 VInstantaneous trip type, with lead-wire terminal block SLTNF/DSN400800 3 UVTSA130-4SWS UVTSA250-4SWS UVTSA480-4SWS UVTSD048-4SWS UVTSD110-4SWSNF/DSN400630 4 UVTSA130-4SWRFS UVTSA250-4SWRFS UVTSA480-4SWRFS UVTSD048-4SWRFS UVTSD110-4SWRFSNF/DSN800 4 UVTSA130-8SWRFS UVTSA250-8SWRFS UVTSA480-8SWRFS UVTSD048-8SWRFS UVTSD110-8SWRFSNF/DSN100016003 UVTSA130-10SWRS UVTSA250-10SWRS UVTSA480-10SWRS UVTND048-10SWRS UVTND110-10SWRS4 UVTSA130-10SWRFS UVTSA250-10SWRFS UVTSA480-10SWRFS UVTND048-10SWRFS UVTND110-10SWRFSBreaker typeNo. ofPolesRated voltagesAC 24 / 48 VAC 100120 V /AC 200240 V /AC 380450 VAC 200250 V /AC 380450 V /AC 460550 VAC 380450 V /AC 460550 V /AC 600690 V DC 24 / 48 V DC 100110 VShort-time delay type, with lead-wire terminal block SLT, short-time delay adjustable in steps 0.10.30.5 secNF/DSN32633 UVTNA048-05SWRSU05 UVTNA450-05SWRSU05 UVTNA550-05SWRSU05 UVTNA690-05SWRSU05 UVTND048-05SWRSU05 UVTND110-05SWRSU054 UVTNA048-05SWRFSU05 UVTNA450-05SWRFSU05 UVTNA550-05SWRFSU05 UVTNA690-05SWRFSU05 UVTND048-05SWRFSU05 UVTND110-05SWRFSU05NF/DSN1252503 UVTSA048-2GSWRSU05 UVTSA450-2GSWRSU05 UVTSA550-2GSWRSU05 UVTSA690-2GSWRSU05 UVTSD048-2GSWRSU05 UVTSD110-2GSWRSU054 UVTSA048-2GSWRFSU05 UVTSA450-2GSWRFSU05 UVTSA550-2GSWRFSU05 UVTSA690-2GSWRFSU05 UVTSD048-2GSWRFSU05 UVTSD110-2GSWRFSU05Short-time delay type, for direct connection, short-time delay adjustable in steps 0.10.30.5 secNF/DSN125250 3/4 UVTSA048-2GSWRNU05 UVTSA450-2GSWRNU05 UVTSA550-2GSWRNU05 UVTSA690-2GSWRNU05 UVTSD048-2GSWRNU05 UVTSD110-2GSWRNU05Breaker typeNo. ofPolesRated voltagesAC 100120 / 200240 / 380450 V AC 200250 / 380450 / 460550 VLong-time delay type, with lead-wire terminal block SLT, long-time delay adjustable in steps 0.51.03.0 secNF/DSN32633 UVTNA450-05SWRSU30 UVTNA550-05SWRSU0304 UVTNA450-05SWRFSU30 UVTNA550-05SWRFSU30NF/DSN1252503 UVTSA450-2GSWRSU30 UVTSA550-2GSWRSU304 UVTSA450-2GSWRFSU30 UVTSA550-2GSWRFSU30Long-time delay type, for direct connection,long-time delay adjustable in steps 0.51.03.0 secNF/DSN125250 3/4 UVTSA450-2GSWRNU30 UVTSA550-2GSWRNU30Types of UVTs32 MITSUBISHI ELECTRICINTERNALACCESSORIES/// INTERNAL ACCESSORIESwith lead-wire terminal block SLT, for 3-pole breakersType Breaker type Rated voltage Art. no.UVTNA048-05SWRSNF/DSN3263AC 24 / 48 V 146399UVTNA130-05SWRS AC 100110 / 120130 V 146401UVTNA250-05SWRS AC 200220 / 230250 V 146403UVTNA480-05SWRS AC 380415 / 440480V 146405UVTNA600-05SWRS AC 500550 / 600 V 146407UVTND048-05SWRS DC 24 / 48 V 146409UVTND125-05SWRS DC 110 / 125 V 146411UVTSA048-2GSWRSNF/DSN125250AC 24 / 48 V 139537UVTSA130-2GSWRS AC 100110 / 120130 V 139539UVTSA250-2GSWRS AC 200220 / 230250 V 139541UVTSA480-2GSWRS AC 380415 / 440480V 139543UVTSA600-2GSWRS AC 500550 / 600 V 139545UVTSD048-2GSWRS DC 24 / 48 V 139547UVTSD110-2GSWRS DC 100 / 110 V 139548UVTSD125-2GSWRS DC 110 / 125 V 139550UVTSA130-4SWSNF/DSN400800AC 100110 / 120130 V 205951UVTSA250-4SWS AC 200220 / 230250 V 205953UVTSA480-4SWS AC 380415 / 440480V 205828UVTSD048-4SWS DC 24 / 48 V 205932UVTSD110-4SWS DC 100 / 110 V 205934UVTSA130-10SWRSNF/DSN10001600AC 100110 / 120130 V 205941UVTSA250-10SWRS AC 200220 / 230250 V 205943UVTSA480-10SWRS AC 380415 / 440480V 205945UVTND048-10SWRS DC 24 / 48 V 205947UVTND110-10SWRS DC 100 / 110 V 205949with lead-wire terminal block SLT, for 4-pole breakersType Breaker type Rated voltage Art. no.UVTNA048-05SWRFSNF/DSN 63AC 24 / 48 V 146400UVTNA130-05SWRFS AC 100110 / 120130 V 146402UVTNA250-05SWRFS AC 200220 / 230250 V 146404UVTNA480-05SWRFS AC 380415 / 440480V 146406UVTNA600-05SWRFS AC 500550 / 600 V 146408UVTND048-05SWRFS DC 24 / 48 V 146410UVTND125-05SWRFS DC 110 / 125 V 146412UVTSA048-2GSWRFSNF/DSN125250AC 24 / 48 V 139538UVTSA130-2GSWRFS AC 100110 / 120130 V 139540UVTSA250-2GSWRFS AC 200220 / 230250 V 139542UVTSA480-2GSWRFS AC 380415 / 440480 V 139544UVTSA600-2GSWRFS AC 500550 / 600 V 139546UVTSD048-2GSWRFS DC 24 / 48 V 137508UVTSD110-2GSWRFS DC 100 / 110 V 139549UVTSD125-2GSWRFS DC 110 / 125 V 139551UVTSA130-4SWRFSNF/DSN400630AC 100110 / 120130 V 205952UVTSA250-4SWRFS AC 200220 / 230250 V 205954UVTSA480-4SWRFS AC 380415 / 440480 V 205955UVTSD048-4SWRFS DC 24 / 48 V 205933UVTSD110-4SWRFS DC 100 / 110 V 205935UVTSA130-8SWRFSNF/DSN800AC 100110 / 120130 V 205936UVTSA250-8SWRFS AC 200220 / 230250 V 205937UVTSA480-8SWRFS AC 380415 / 440480 V 205938UVTSD048-8SWRFS DC 24 / 48 V 205939UVTSD110-8SWRFS DC 100 / 110 V 205940UVTSA130-10SWRFSNF/DSN10001600AC 100110 / 120130 V 205942UVTSA240-10SWRFS AC 200220 / 230250 V 205944UVTSA480-10SWRFS AC 380415 / 440480 V 205946UVTND048-10SWRFS DC 24 / 48 V 205948UVTND110-10SWRFS DC 100 / 110 V 205950Order Information for Undervoltage Tripping Devices UVTUndervoltage tripping device UVT, instantaneous trip type, synchronous closing, mounted on right-sideType Breaker type Rated voltage Art. no.UVTSA048-2GSWRNNF/DSN125250AC 24 / 48 V 139552UVTSA130-2GSWRN AC 100110 / 120130 V 139553UVTSA250-2GSWRN AC 200220 / 230250 V 139554UVTSA480-2GSWRN AC 380415 / 440480 V 139555UVTSA600-2GSWRN AC 500550 / 600 V 139556UVTSD048-2GSWRN DC 24 / 48 V 139557UVTSD110-2GSWRN DC 100 / 110 V 139558UVTSD125-2GSWRN DC 110 / 125 V 139559for direct connection, for 3- and 4-pole breakersfor synchronous closing on request33 MITSUBISHI ELECTRICINTERNALACCESSORIESINTERNAL ACCESSORIES ///Order Information for Undervoltage Tripping Devices UVTwith lead-wire terminal block SLT, for 3-pole breakersType Breaker type Rated voltage Art. no.UVTNA048-05SWRSU05NF/DSN3263AC 24 / 48 V 146413UVTNA450-05SWRSU05AC 100120 / 200240 /380450 V146425UVTNA550-05SWRSU05AC 200250 / 380450 /460550 V146427UVTNA690-05SWRSU05AC 380450 / 460550 /600690 V146429UVTND048-05SWRSU05 DC 24 / 48 V 146431UVTND110-05SWRSU05 DC 100110 V 146433UVTSA048-2GSWRSU05NF/DSN125250AC 24 / 48 V 139560UVTSA450-2GSWRSU05AC 100120 / 200240 /380450 V139562UVTSA550-2GSWRSU05AC 200250 / 380450 /460550 V139564UVTSA690-2GSWRSU05AC 380450 / 460550 /600690 V139566UVTSD048-2GSWRSU05 DC 24 / 48 V 139568UVTSD110-2GSWRSU05 DC 100 / 110 V 139569UVTSA450-4SWSU05NF/DSN400630AC 100120 / 200240 /380450 V205818UVTSD048-4SWSU05 DC 24 / 48 V 205838UVTSD110-4SWSU05 DC 100 / 110 V 205842UVTSA450-10SWRU05NF/DSN10001600AC 100120 / 200240 /380450 V205856UVTSA550-10SWRU05AC 200250 / 380450 /460550 V205868UVTND048-10SWRU05 DC 24 / 48 V 205876UVTND110-10SWRU05 DC 100 / 110 V 205880Undervoltage tripping device UVT, short-time delay type, adjustable in steps 0.10.30.5 sec, mounted on right-sidewith lead-wire terminal block SLT, for 4-pole breakersType Breaker type Rated voltage Art. no.UVTNA048-05SWRFSU05NF/DSN3263AC 24 / 48 V 146424UVTNA450-05SWRFSU05AC 100120 / 200240 /380450 V146426UVTNA550-05SWRFSU05AC 200250 / 380450 /460550 V146428UVTNA690-05SWRFSU05AC 380450 / 460550 /600690 V146430UVTND048-05SWRFSU05 DC 24 / 48 V 146432UVTND110-05SWRFSU05 DC 100110 V 146434UVTSA048-2GSWRFSU05NF/DSN125250AC 24 / 48 V 139561UVTSA450-2GSWRFSU05AC 100120 / 200240 /380450 V139563UVTSA550-2GSWRFSU05AC 200250 / 380450 /460550 V139565UVTSA690-2GSWRFSU05AC 380450 / 460550 /600690 V139567UVTSD048-2GSWRFSU05 DC 24 / 48 V 137509UVTSD110-2GSWRFSU05 DC 100 / 110 V 139570UVTSA450-4SWRFSU05NF/DSN400630AC 100-120 / 200-240 /380-450 V205819UVTSD048-4SWRFSU05 DC 24 / 48 V 205839UVTSD110-4SWRFSU05 DC 100 / 110 V 205843UVTSA450-8SWRFSU05NF/DSN800AC 100-120 / 200-240 /380-450 V205845UVTDS048-8SWRFSU05 DC 24 / 48 V 205852UVTDS110-8SWRFSU05 DC 100 / 110 V 205854UVTSA450-10SWRFU05NF/DSN10001600AC 100120 / 200240 /380450 V205858UVTSA550-10SWRFU05AC 200250 / 380450 /460550 V205872UVTND048-10SWRFU05 DC 24 / 48 V 205878UVTND110-10SWRFU05 DC 100 / 110 V 205882for direct connection, for 3- and 4-pole breakersType Breaker type Rated voltage Art. no.UVTSA048-2GSWRNU05NF/DSN125250AC 24 / 48 V 139571UVTSA450-2GSWRNU05AC 100120 / 200240 /380450 V139572UVTSA550-2GSWRNU05AC 200250 / 380450 /460550 V139573UVTSA690-2GSWRNU05AC 380450 / 460550 /600690 V139574UVTSD048-2GSWRNU05 DC 24 / 48 V 139575UVTSD110-2GSWRNU05 DC 100110 V 13957634 MITSUBISHI ELECTRICINTERNALACCESSORIES/// INTERNAL ACCESSORIESwith lead-wire terminal block SLT, for 3-pole breakersType Breaker type Rated voltage Art. no.UVTNA450-05SWRSU30NF/DSN3263AC 100120 / 200240 /380450 V146435UVTNA550-05SWRSU30AC 200250 / 380450 /460550 V146437UVTSA450-2GSWRSU30NF/DSN125250AC 100120 / 200240 /380450 V139577UVTSA550-2GSWRSU30AC 200250 / 380450 /460550 V139579UVTSA450-4SWSU30 NF/DSN400800AC 100120 / 200240 /380450205826UVTSA550-10SWRU30 NF/DSN10001600AC 200250 / 380450 /460550 V205870with lead-wire terminal block SLT, for 4-pole breakersType Breaker type Rated voltage Art. no.UVTNA450-05SWRFSU30NF/DSN3263AC 100120 / 200240 /380450 V146436UVTNA550-05SWRFSU30AC 200250 / 380450 /460550 V146438UVTSA450-2GSWRFSU30NF/DSN125250AC 100120 / 200240 /380450 V139578UVTSA550-2GSWRFSU30AC200250 / 380450 /460550V139580UVTSA450-4SWRFSU30 NF/DSN400630AC 100120 / 200240 /380450205827UVTSA450-8SWRFSU30 NF/DSN800AC 100120 / 200240 /380450205849UVTSA450-10SWRFU30NF/DSN10001600AC 100120 / 200240 /380450205866UVTSA550-10SWRFU30AC 200250 / 380450 /460550 V205874Undervoltage tripping device UVT, long-time delay type, adjustable in steps 0.51.03.0 sec, mounted on right-sidefor direct connection, for 3- and 4-pole breakersType Breaker type Rated voltage Art. no.UVTSA450-2GSWRNU30NF/DSN125250AC 100120 / 200240 /380450 V139581UVTSA550-2GSWRNU30AC 200250 / 380450 /460550 V13958235 MITSUBISHI ELECTRICEXTERNALACCESSORIESEXTERNAL ACCESSORIES ///Accessories for Connection and InstallationIf no connection method is specified withthe order, we deliver the standard fixed-installation type with front connection.The front-connection model can be modi-fied to other types (excluding plug-in)with special purchase options.More details on request.Connection TypesInstallation Fixed Plug-inConnection Front (F) Rear (B) Rear (PM)AppearanceStandard Option OptionMITSUBISHI OFFONNO-FUSE BREAKERNF125-SGWIn A 100Ir 63-100AMODELPOLEUi690VCat.APUSH TOTRIPUimp 8kV3 PIEC60947-2 JIS C 8201-2 Ue 690VAC 525VAC 500VAC 440VAC 380/415VAC 230VAC 300VACEN60947-2 40C Icu/Ics 8/8kA 22/22kA 30/30kA 36/36kA 36/36kA 85/85kA 20/20kAMITSUBISHI ELECTRICPAL 70% 50/60HzTTs TL Ii Is Ir IpIi(X100A) Ir(A) TL(S) IS(xIr) TS(S) Ip(xIr)63 100 100 12 2 2.5 10 .06 .07 .10 .3 46 8 10 1214.1 .28 7 6 5 4 80 3.5 3 60 80OVER MODEL RE100 In 100AMITSUBISHI OFFONNO-FUSE BREAKERNF125-SGWIn A 100Ir 63-100AMODELPOLEUi690VCat.APUSH TOTRIPUimp 8kV3 PIEC60947-2 JIS C 8201-2 Ue 690VAC 525VAC 500VAC 440VAC 380/415VAC 230VAC 300VACEN60947-2 40C Icu/Ics 8/8kA 22/22kA 30/30kA 36/36kA 36/36kA 85/85kA 20/20kAMITSUBISHI ELECTRICPAL 70% 50/60HzTTs TL Ii Is Ir IpIi(X100A) Ir(A) TL(S) IS(xIr) TS(S) Ip(xIr)63 100 100 12 2 2.5 10 .06 .07 .10 .3 46 8 10 1214.1 .28 7 6 5 4 80 3.5 3 60 80OVER MODEL RE100 In 100AMITSUBISHI OFFONNO-FUSE BREAKERNF125-SGWIn A 100Ir 63-100AMODELPOLEUi690VCat.APUSH TOTRIPUimp 8kV3 PIEC60947-2 JIS C 8201-2 Ue 690VAC 525VAC 500VAC 440VAC 380/415VAC 230VAC 300VACEN60947-2 40C Icu/Ics 8/8kA 22/22kA 30/30kA 36/36kA 36/36kA 85/85kA 20/20kAMITSUBISHI ELECTRICPAL 70% 50/60HzTTs TL Ii Is Ir IpIi(X100A) Ir(A) TL(S) IS(xIr) TS(S) Ip(xIr)63 100 100 12 2 2.5 10 .06 .07 .10 .3 46 8 10 1214.1 .28 7 6 5 4 80 3.5 3 60 80OVER MODEL RE100 In 100ARear studs STTypeNo. ofPolesBreaker type Art. no.ST-05SW3 3NF/DSN3263146441ST-05SW4 4 146442ST-2GSW3 3NF/DSN125250139591ST-2GSW4 4 139592ST-4SW3 3NF/DSN400205956ST-4SW4 4 205957ST-6SW3 3NF/DSN630205958ST-6SW4 4 205959ST-8SW3 3NF/DSN800205960ST-8SW4 4 205961Plug-in sets PMTypeNo. ofPolesBreaker type Protection degree Art. no.PM-05SW3 3NF/DSN3263 146443PM-05SW4 4 146444PM-2GSWIP3 3NF/DSN125250 IP 20137511PM-2GSWIP4 4 137512PM-4SW3 3NF/DSN400 205962PM-4SW4 4 205963PM-6SW3 3NF/DSN630 205964PM-6SW4 4 205965PM-8SW3 3NF/DSN800 205966PM-8SW4 4 205967Connection AccessoriesMore types available on request.Frame size Front (Standard) Rear Solderless terminals Plug-in32250 A 400800 A 10001600 A Only for frame sizes 125/160/250 AOn request, modified at factory.Available Terminal ConnectionsSolderless terminals SLTypeNo. ofPolesBreaker type Art. no. Packing unit Connected wire size Used forSL-2GSW3 3NF/DSN125250139593 1 Set =3 pcs.2.5185 mm Cu/AlSL-2GSW4 4 139594 1 Set =4 pcs.36 MITSUBISHI ELECTRICEXTERNALACCESSORIES/// EXTERNAL ACCESSORIESV-Type Operating HandleMITSUBISHIOFFONNO-FUSE BREAKERNF125-SGWIn A 100Ir 63-100AMODELPOLEUi690VCat.APUSH TOTRIPUimp 8kV3 PIEC60947-2JIS C 8201-2Ue690VAC525VAC500VAC440VAC380/415VAC230VAC300VACEN60947-240CIcu/Ics8/8kA22/22kA30/30kA36/36kA36/36kA85/85kA20/20kAMITSUBISHI ELECTRICPAL 70%50/60HzTTs TL Ii IsIrIpIi(X100A)Ir(A) TL(S) IS(xIr) TS(S) Ip(xIr)63 100 100 12 22.5 10 .06 .07 .10 .3 468 101214.1 .287 6 5 4 80 3.53 60 80OVER MODELRE100 In 100AR E S ETOFFTRIPPEDPUSH TO TRIPONApplicationThe V-type operating handle is used to operate the breaker whichis installed in a cabinet. With the installed V-type operating handlethe breaker can be locked (with up to 3 padlocks, 8 mmmax.,padlocks are not included) in OFF position only.The door is locked when the breaker is ONand can only beopened when the breaker is in OFF position.The V-type operating handle is available in the following colourcombinations:Handle andfront inblack/black andhandle andfront inred/yellow,or red/black, see also the following table. Protection degree (in accord. to IEC/EN60 529): see table below. Variable axle length.SpecificationsV-type operating handleV05SWN V05SWEN V2GSWN V2GSWEN V2GUWN V2GUWEN V4SW V4SWE V8SW V8SWE V101 V101EBreaker type NF/DSN3263NF/DSN125/160/250-SGW/HGWNF125/250-RGW/UGW NF/DSN400630 NF/DSN800 NF/DSN10001600Colour: handle/front black red/yellow black red/yellow black red/yellow black red/yellow black red/yellow black red/blackProtection degree IP65 IP65 IP65 IP65 IP65 IP65 IP65 IP65 IP65 IP65 IP50 IP50Art. no. 146457 146458 137513 139627 139626 139628 203761 203762 203763 203764 11659 11663R-Type Operating HandleMITSUBISHIOFFONNO-FUSE BREAKERNF125-SGWIn A 100Ir 63-100AMODELPOLEUi690VCat.APUSH TOTRIPUimp 8kV3 PIEC60947-2JIS C 8201-2Ue690VAC525VAC500VAC440VAC380/415VAC230VAC300VACEN60947-240CIcu/Ics8/8kA22/22kA30/30kA36/36kA36/36kA85/85kA20/20kAMITSUBISHI ELECTRICPAL 70%50/60HzTTs TL IiIsIrIpIi(X100A)Ir(A) TL(S) IS(xIr) TS(S) Ip(xIr)63 100 100 12 22.510 .06 .07 .10 .3 468 101214.1 .2876 5 4 80 3.53 60 80OVER MODELRE100 In 100A RESETOFFTRIPPEDPUSH TO TRIPONApplicationThe R-type operating handle is to be mounted directly on thebreaker.With the installed R-type operating handle the breaker can belocked (with up to 3 padlocks, 8 mmmax., padlocks are notincluded) in OFF position only.The R-type operating handle is available in the following colourcombinations:Handle andfront inblack/black andhandle andfront inred/yellow,or red/black, see also the following table.SpecificationsR-type operating handleR2GSWN R2GSWEN R2GUWN R2GUWEN R4SW R4SWE R8SW R8SWE R101 R101EBreaker type NF/DSN125/160/250-SGW/HGW NF125/250-RGW/UGW NF/DSN400630 NF/DSN800 NF/DSN10001600Colour: handle/front black red/yellow black red/yellow black red/yellow black red/yellow black red/blackArt. no. 139622 139624 139623 139625 203765 203766 203767 203769 11620 11623Example:cabinet door37 MITSUBISHI ELECTRICEXTERNALACCESSORIESEXTERNAL ACCESSORIES ///Handle Lock DevicesApplicationThe handle lock device HL is used to lock the handle of thebreaker against switching by not-allowed persons. The functionof protection is given every time.Different types are available. All handle lock devices can be mounted regardless of the num-ber of poles. Padlocks are not included. More details on request.LC-2GSWHLF-2GSWHLF3-2GSWHLS-2GSWHL-4SWHandle lock device LC type The handle lock can be used without padlock as a lock cover.Handle lock device HL type The handle lock HL type can be used for 3- and 4-pole breakertypes. The handle locks can be used without padlock as lock covers. The HLF types are used for OFF-lock and the HLN types areused for ON-lock. The handle lock HLF3 type enables the user to lock the handlewith up to three padlocks against switching. The HLS types are used for OFF-lock only.Type Breaker type Art. no.LC-05SW NF/DSN3263 146453LC-2GSW NF/DSN125250 139613HLF-05SW NF/DSN3263 146454HLF-2GSW NF/DSN125250 139614HLF3-2GSW NF/DSN125250 139615HLN-05SW NF/DSN3263 146455HLN-2GSW NF/DSN125250 139616HLS-05SW NF/DSN3263 146456HLS-2GSW NF/DSN125250 139617HL-4SW NF/DSN400800 205975HL-10SW NF/DSN1001600 20597638 MITSUBISHI ELECTRICEXTERNALACCESSORIES/// EXTERNAL ACCESSORIESElectrically Operated Breakers OverviewMITSUBISHIOFFONNO-FUSE BREAKERNF125-SGWIn A 100Ir 63-100AMODELPOLEUi690VCat.APUSH TOTRIPUimp 8kV3 PIEC60947-2JIS C 8201-2Ue690VAC525VAC500VAC440VAC380/415VAC230VAC300VACEN60947-240CIcu/Ics8/8kA22/22kA30/30kA36/36kA36/36kA85/85kA20/20kAMITSUBISHI ELECTRICPAL 70%50/60HzTTs TL Ii IsIrIp OVER MODELRE100 In 100AONMITSUBISHI ELECTRICU cPush to(MANU)NO-FUSE BREAKERNF250-SGWMSDBA-NF25GSWA0106MODELPushPullMODELSERIAL:Ui 690VCat.AIEC60947-2JIS C 8201-2Ue690VAC525VAC500VAC440VAC380/415VAC230VACMANUAUTORATED CURRENT250 AUimp 8kVEN60947-240CIcu/Ics8/8kA22/22kA30/30kA36/36kA36/36kA85/85kA50/60HzPush toOPEN(TRIP)ONDis-chargeControl circuitvoltage should besupplied to P1and P2 terminals.P1 P2 S1 S2 S4MITSUBISHIPOWER SUPPLY MODULEMODEL MDSPSA240-SWCONTROLL CIRCUIT VOLTAGEAC100-240V/DC100-250VS 4O p e r a t i n g C i r c u i tS 2 P 2S 1 P 1P 1P 2S 1S 2S 4U cO NK 3K 2K 2K 1 K 1S W 1 K 3K 3 K 2 K 1P o w e rS u p p l yO F FIi(X100A)Ir(A) TL(S) IS(xIr) TS(S) Ip(xIr)63 100 100 12 2 2.5 10 .06 .07 .10 .3 468 101214.1 .287 6 5 4 80 3.5 3 60 80Spring-charged types MDSSpecifications MDSD.../MDSA... MDS-4.../8... MDS-16...Breaker typeNF-S/H seriesNF125-SGW/ HGWNF160-SGW/ HGWNF250-SGW/ HGWNF400-SEW/ HEW/ REWNF630-SEW/ HEW/ REWNF800-SEW/ HEW/ REWNF1000-SEWNF1250-SEWNF1600-SEWNF-R/U seriesNF125-RGW/ UGWNF250-RGW/ UGWNF400-UEW, NF800-UEW Rated operating voltage (V)(allowable voltage range85110%)DC 24 VDC4860VAC100240V / DC100250VAC 100/110 V, 200/220 V (AC 240 V)DC 100/110 V (DC 125 V)AC 100/110 V, 200/220 V (AC 240 V)DC 100/110 V (DC125 V)Operating current(A, eff.)DC 100 / 110 V 0.20 OFF: 1.0 (3.0) ON: 8.0 OFF: 1.0 (3.0) ON: 9.0AC100 / 110 V 0.50 OFF: 1.0 (3.0) ON: 10.0 OFF: 1.0 (3.0) ON: 10.0200 / 200 V 0.35 OFF: 0.5 (1.5) ON: 8.0 OFF: 0.5 (1.5) ON: 8.0Operating time (sec.)ON operating 0.050.1 (self holding) 0.05 0.07OFF operating 0.6 and less (self holding) 3 and less (self holding) 3 and less (self holding)Spring charging 1.2 and less Transformer capacity required (VA) 150 700 700Endurance voltage (V) 1500 1500 1500Also usable for Disconnectors DSN with 3 and 4 poles.The voltages in parentheses ( ) are special options and might require an external resistor. For details, consult your distributor.The values in parentheses ( ) showstarting current.General precautions for motor-operated electrical MCCBs The motor operated types should notbe operated 10 times consecutively(one on/off counts as an operation). The operating voltage should bebetween 85 110 %of the rated con-trol voltage. The current breaker position ON, OFFor TRIPPED will be shown with a specialdisplay on the motor. The dielectric strength of the electricaloperating circuits is 1500 V. When per-forming a dielectric strength testsimultaneously with another device ata voltage over 1500 V, the operatingcircuit terminal should be discon-nected.Automatic ResetIf the breaker is an auto reset type, it con-tains a built-in alarmswitch and theoff-control circuit close when the breaker istripped. Since the breaker automaticallyresets itself after tripping, the power is eas-ily restored by switching on the breakeragain. With a UVT mounted, however, autoreset may not be possible. In this case,please consult your distributor. More details on request.JISUe550VAC460VAC220VACIEC 60947-2EN 60947-2500VAC250VACIcn35kA50kA85kAIcu/Ics10/10kA30/30kA42/42kA45/45kA85/85kA40C50kA85kAMITSUBISHI ELECTRICOFFONMITSUBISHINO-FUSE BREAKERNF400-SEP400A400MODELPOLEUi 690VAC50 - 60Hz8kVPUSH TOTRIPUimp3 PIp(xIr)TESTTL(sec) TS(sec)100 1260 80IS(xIr)22.5 1087 6 5 3003504 3.53.06 .3.1 .2Ii(X400A)468 10121614.07 .10Ir(A)200220250400TTs TL Ii IsIrIp Ip(xIr)TESTTL(sec) TS(sec)100 1260 80IS(xIr)22.5 1087 6 5 3003504 3.53.06 .3.1 .2Ii(X400A)468 10121614.07 .10Ir(A)200220250400OFFSpring-charged type MDS-4SWA110and breaker type NF400-SEWSpring-charged type MDSAD240-NF2GSWEand breaker type NF250-SGW39 MITSUBISHI ELECTRICEXTERNALACCESSORIESEXTERNAL ACCESSORIES ///Spring-Charged Type MDSType Breaker type Rated voltage Art. no.MDSD024-NF2GSWENF/DSN125250DC 24 V 139583MDSD060-NF2GSWE DC4860V 139584MDSAD240-NF2GSWE AC100240V / DC100250V 137514MDS-4SWA110NF/DSN400630AC 100110 V 205968MDS-4SWA240 AC 230 V 205969MDS-4SWD110 DC 100110 V 205970MDS-8SWA110NF/DSN800DC 100110 V 205971MDS-8SWA240 AC 230 V 205972MDS-8SWD110 DC 100110 V 205973MDS-16SSA110NF/DSN10001600AC 100110 V 11463MDS-16SSA220 AC 230 V 9430MDS-16SSD110 DC 100110 V 11464MITSUBISHIOFFONNO-FUSE BREAKERNF125-SGWIn A 100Ir 63-100AMODELPOLEUi690VCat.APUSH TOTRIPUimp 8kV3 PIEC60947-2JIS C 8201-2Ue690VAC525VAC500VAC440VAC380/415VAC230VAC300VACEN60947-240CIcu/Ics8/8kA22/22kA30/30kA36/36kA36/36kA85/85kA20/20kAMITSUBISHI ELECTRICPAL 70%50/60HzTTs TL Ii IsIrIp OVER MODELRE100 In 100AIi(X100A)Ir(A) TL(S) IS(xIr) TS(S) Ip(xIr)63 100 100 12 22.5 10 .06 .07 .10 .3 468 101214.1 .2876 5 4 80 3.53 60 80ONMITSUBISHI ELECTRICU cPush to(MANU)NO-FUSE BREAKERNF250-SGWMSDBA-NF25GSWA0106MODELPushPullMODELSERIAL:Ui 690VCat.AIEC60947-2JIS C 8201-2Ue690VAC525VAC500VAC440VAC380/415VAC230VACMANUAUTORATED CURRENT250 AUimp 8kVEN60947-240CIcu/Ics8/8kA22/22kA30/30kA36/36kA36/36kA85/85kA50/60HzPush toOPEN(TRIP)ONDis-chargeControl circuitvoltage should besupplied to P1and P2 terminals.P1 P2 S1 S2 S4MITSUBISHIPOWER SUPPLY MODULEMODEL MDSPSA240-SWCONTROLL CIRCUIT VOLTAGEAC100-240V/DC100-250VS 4O p e r a t i n g C i r c u i tS 2P 2S 1P 1P 1P 2S 1S 2S 4U cO NK 3K 2K 2K 1 K 1S W 1 K 3K 3 K 2 K 1P o w e rS u p p l yO F FJISUe550VAC460VAC220VACIEC 60947-2EN 60947-2500VAC250VACIcn35kA50kA85kAIcu/Ics10/10kA30/30kA42/42kA45/45kA85/85kA40C50kA85kAMITSUBISHI ELECTRICOFFONMITSUBISHINO-FUSE BREAKERNF400-SEP400A400MODELPOLEUi 690VAC50 - 60Hz8kVPUSH TOTRIPUimp3 PIp(xIr)TESTTL(sec) TS(sec)100 1260 80IS(xIr)22.5 10876 5 3003504 3.53.06 .3.1 .2Ii(X400A)468 10121614.07 .10Ir(A)200220250400TTs TL Ii IsIrIpIp(xIr)TESTTL(sec) TS(sec)100 1260 80IS(xIr)22.5 10876 5 3003504 3.53.06 .3.1 .2Ii(X400A)468 10121614.07 .10Ir(A)200220250400OFFOFFOFFSpring-charged typeMDS.....-NF2GSWEand breaker type NF250-SGWSpring-charged typeMDS-4SW.... andbreaker type NF400-SEWAutomatic reset type requires theadditional wiring shown by thedotted lines.Control powersupplyS1 P1 P2(DC-)S4ALMotor operated deviceControl circuit for MDS-4/8/16 S..... Control circuit for MDS....-NF2GSWES2 P1 P2 S4ALS1MDS module formotor operated deviceAlarmswitch(AL-a contact)for automatic resetAlarmswitch(AL-a contact)for automatic resetAutomatic reset type requires theadditional wiring shown by thedotted lines.Control powersupplyOFFResetSpring-Charged TypeElectrical operationWhen the ONswitch is closed, the coil isreleasing the latch mechanism, and thebreaker is turned to ON.When the OFF switch is closed. a relay oper-ates to start a motor which turns thebreaker OFF (RESET) and charges thespring at the same time.Manual operationWhen the ONbutton (on the front of thespring-charged type) is pressed, the latchmechanismis cancelled and the circuitbreaker set momentarily to ONby the forceof spring.OFF operation(RESET operation)The circuit breaker can be set to OFF(RESET) by pressing the leaf spring, pullingout the manual handle and moving it backand forth more than ten times. This chargesthe spring at the same time.Cautions during electrical operationWhen an electrical-operation device ismounted in a breaker or removed fromanbreaker, this device must be returned tothe discharged state after tripping of thebreaker.A MCCB with an electrical-operation devicewill not trip in the OFF state "PUSHTOTRIP"is used. This does not indicate that thebreaker is faulty.Since it takes 3 sec to switch off a breakerprovided with this device, if the breakerneeds to be opened urgently by remotecontrol, a breaker fitted with an SHT or UVTshould be used.The breaker is equipped with a relay for theprevention of pumping.Control circuitFor breakers with automatic resettingcapability, add the connection indicated bythe dotted line in the diagrams. More details on request.ON OFFResetON40 MITSUBISHI ELECTRICEXTERNALACCESSORIES/// EXTERNAL ACCESSORIESTerminal CoversApplicationThe terminal covers are used to avoid exposure of charged parts.Different types are available: for front connection as small terminal covers TCS or large termi-nal covers TCL, TTC (see figures below) for rear connection as closed type BTC for plug-in as PTC One set includes two pieces of terminal covers. Colour: black, white or transparent More types/details on request. MITSUBISHIOFFONNO-FUSE BREAKERNF125-SGWIn A 100Ir 63-100AMODELPOLEUi690VCat.APUSH TOTRIPUimp 8kV3 PIEC60947-2JIS C 8201-2Ue690VAC525VAC500VAC440VAC380/415VAC230VAC300VACEN60947-240CIcu/Ics8/8kA22/22kA30/30kA36/36kA36/36kA85/85kA20/20kAMITSUBISHI ELECTRICPAL 70%50/60HzTTs TL Ii IsIrIpIi(X100A)Ir(A) TL(S) IS(xIr) TS(S) Ip(xIr)63 100 100 12 22.5 10 .06 .07 .10 .3 468 101214.1 .2876 5 4 80 3.53 60 80OVER MODELRE100 In 100ASmall terminal coversTCSLarge terminal coversTCL, TTCTCS type terminal coversCircuit breakerNF250-SGWSmall terminal covers TCS(1 set = 2 pieces)TypeNo. ofpolesBreaker type ColourProtectiondegreeArt. no.TCS-05SW3W 3NF/DSN3263 white IP20146447TCS-05SW4W 4 146448TCS-2GSW3W 3NF/DSN125250 white IP40139605TCS-2GSW4W 4 139606Large terminal covers TCL(1 set = 2 pieces)TypeNo. ofpolesBreaker type ColourProtectiondegreeArt. no.TCL-05SW3W 3NF/DSN3263 white IP20146445TCL-05SW4W 4 146446TCL-2GSW3W 3NF/DSN125250 white IP40139603TCL-2GSW4W 4 139604TCL-4SW3 3NF/DSN400630blackIP20205977TCL-4SW4 4 transparent 205978TCL-8SW3 3NF/DSN800 transparent IP20205979TCL-8SW4 4 205980TCL-8UW3 3NF/DSN800 transparent IP20205981TCL-8UW4 4 205982TCL-10SW3 3NF/DSN10001250(fixed with screws)transparent IP20205983TCL-10SW4 4 205984Large terminal covers TTC(1 set = 2 pieces)TypeNo. ofpolesBreaker type ColourProtectiondegreeArt. no.TTC-2GSW3 3NF/DSN125250 transparent IP40139611TTC-2GSW4 4 139612Terminal covers rear connection studs BTC(1 set = 2 pieces)TypeNo. ofpolesBreaker type ColourProtectiondegreeArt. no.BTC-05SW3W 3NF/DSN3263 white IP20146449BTC-05SW4W 4 146450BTC-2GSW3W 3NF/DSN125250 white IP40139607BTC-2GSW4W 4 139608BTC-4SW3 3NF/DSN400630 transparent IP20205985BTC-4SW4 4 205986BTC-8SW3 3NF/DSN800 transparent IP20205987BTC-8SW4 4 205988Terminal covers for 3-pole plug-in type PTC(1 set = 2 pieces)TypeNo. ofpolesBreaker type ColourProtectiondegreeArt. no.PTC-05SW3W 3NF/DSN3263 white IP20146451PTC-05SW4W 4 146452PTC-2GSW3W 3NF/DSN125250 white IP40139609PTC-2GSW4W 4 13961041 MITSUBISHI ELECTRICEXTERNALACCESSORIESEXTERNAL ACCES