    Minilec Microprocessor Based Alarm Annunciators aredesigned to keep an alert & watchful eye on your plant &processes. The entire range has been designed with an

    insight into the modern day manufactur ing plant & its futurerequirements. Minilec Alarm Annunciators are equipped

    with microprocessor-based design, super bright LED faciawindows, site selectable, programmed sequences as perISA standard & thoughtful provisions for troubleshooting &maintenance. Dynamic, Aler t & Responsive These unique

    advantages have helped the Minilec Annunciators to be anicon in the power T & D industry & engineeringestablishments in India. The world class Minilec

    Annunciator has made its presence felt in Overseasmarkets.

    MODELS

    MICROWARN 0600,MBAS 0600,MBAS 9700,MBAS 09,MBAS 08,Annunciation Panels, Microfacia

    Ordering InstructionsProduct Family NameModel Name

    Aux. Supply / Controlsupply voltageNo. of Inputs (Windows)Operating sequence

    FEATURES 4 windows to 128 windows Integral & Split models Microprocessor based

    Super bright LEDs for facia Standard operating sequences Any other custom- made sequences NO-NC & Trip Non-Trip site

    selectable Repeat relays Supply fail annunciation / Indication Choice of 3 window sizes Choice of five colours RS 232 / RS 485 Output Port

    51

    ALARM ANNUNCIATORS

    FUNCTIONS Continuous monitoring of input

    parameters Control of process through outputs &

    software Data acquisition & communication Data Storage & records through PC

  • 8/10/2019 minilecAlarm Annunciators

    2/10

    MBAS 0600

    MBAS 0600 is a improved version of earlier MBAS 9400 and is available for 4 to 32 windows

    52

    The Design Features

    Single chip microcontroller logic Opto isolated inputs and outputs

    Super Bright LED window illumination High Noise immunity / isolation Switch mode power supply

    Self surveillance watchdog LED

    The Constructional Flexibili ty

    Conforming to DIN panel cutouts Replaceable snap-on window capsules

    Two different window size Moulded enclosures

    The Functional Features

    Fixed Sequence ( S1/S2/S3/S4)

    Potential free dry contact inputs

    NO/NC inputs selectable configuration

    Relay output for external Audiblerd

    Hooter 3 Relay (optional) for either of

    below m entioned features

    a) Ring back hooter

    b) Supervisory control

    M in i lec Standard CommunicationProtocol

    Optional Features Fault Follower contact output

    Any custom built operating per fault Input (NO or NC)sequences Supply fail indication /

    Manned / Unmanned function annunciation Built- in M ODBUS RTU/ ASCII Protocol Built- in control push buttons

    System Enclosur esThe MBAS 0600 annunciation systems is configured in multiples

    of four basic ABS moulded enclosures

    Size 1 D Size 2 D Size 3 D Size 4 D

    Basic Standard Enclosures

    *

    A L A R M A N N U N C I A T O R S

    10B8SPO

    1D

    10B6SP0

    1D

    22B10SP0

    2D

    20B16SPO

    2D

    14B0SPO

    1D

    28B0S0O

    2D

    Back view showing Terminal details

    PowerSupply

    DIPfor

    SequenceSelection

    Switches

    OutputRelays

    Fuse

    RepeatRelay

    Terminal

    Fault InputTerminals

    RS 232Port

    DIP forNO/NC &Grouping

    Manned /Unmanned

    PC Side software

    Functional Block Diagram

  • 8/10/2019 minilecAlarm Annunciators

    3/10

  • 8/10/2019 minilecAlarm Annunciators

    4/10

    A L A R M A N N U N C I A T O R S

    M INILEC offers its unique alarmAnnunciator based on the latest single

    chip micro-controller technology with serialcommunication facility. Available in 19 rack type

    enclosure. MBAS 9700 annunciators have split architecturefor 16, 24, 32, 40, 48, 64, 80 ,96 ,112 & 128 windows. 24, 32,

    48, 64, 80, 96,112, & 12 8 window m odels are housed in 19 racktype enclosures, separate for MCU & for PSU. Here choice of facia

    (DFU) is of 3 types (a) Sm all size i.e. 30 x 30 m m and (b ) Big size is 30x 65 m m ( c) 5 0 x 70 mm. (on request) Facia is available in multiples of16 windows. In addition to all other standard features, MBAS 9700has additional facility of computer linking. A serial port(RS232/RS485) o utput is available which c an be supported by an

    IBM compatible PC of minimum 386 configuration. Minilec cansupply the standard software with every model or can

    develop suitable softw are as per custom er requirementsor can provide source coding / protocol details to

    enable client to develop their own suitablesoftware.

    STANDARD FEATURESS ingle chip micro-control ler log ic . Super

    bright LED's for window illumination. Siteselectable NO/NC type fault con tacts. Siteselectable trip /Non trip (Grouping) . Easy cardreplacement & hence fault diagnosis. SwitchMo de Power Supply. (Suitable for Both AC/DCSupply) High noise imm unity and wide inputsupply variation. Opto-isolated Inputs andOutputs. Site Selectable sequences. Potentialfree dry input contacts. Two different windowsizes. Replaceable window lens & windowlegends. Computer linking for fault logging withprinter facility for report. Self-surveillance watchdog LED. Relay output for external audible

    hooter. D iagnost ics Menu Redundant PowerSupply CPU fail & PSU fail indicatio n w ith relayoutput contact (Only in 19 Rack)

    User Friendlyterminal Connectors

    CONSTRUCTIONAL DETAILSMBAS 9700 consist of fourbasic sections1) The Power Supply Unit (PSUModule).2) The Main Control Unit (CPU +IOU Mo dule).3) The Display Facia Unit(DFU Mo dule).4) Computer interface.

    THE MAIN CONTROLUNIT (MCU)CPU module is the MainProcessing Unit of MBAS9700 which scans andprocesses the incoming faults i g n a l s f r o m t h e v a r i o u spotential free field contactsthrough IOU module, and drivesthe corresponding LED window s

    and the audible device in order toannunciate the fault through IOUmodule. The IOU module is theinput & output interfacing unit.To each IOU mo dule 16 inputcontacts (potential free) & 16w i n d o w L E D ' s c a n b econnected.

    THE DISPLAY FACIAUNIT (DFU)

    T h e F a c i a b l o c k i saccessible from front (in

    moulded enclosure) andc o n s t i t u t e s o f w i n d o w

    capsules. The sandwichedphoto film window inscriptionsare press fitted on the windowcapsules.

    For 16 to 12 8 points system theDFUs are g iven sep arately.

    OPTIONAL FEATURES Different colored LED's in eachwindow for easy differentiationof c ritical faults. Customized preprogramm ed

    operating sequence. M u l t i c h a n n el s e r ia l

    c o m m u n i c a t i o n(8 Annunciators & singlecomputer) Repeat Relay Card

    THE POWER SUPPLY UNIT (PSU)PSU converts the available power source into aregulated and filtered DC output, which is fed tothe MCU Module & DFUs. The pow er supply canaccept Specified AC or DC I/P supply, dependingupon the application. Redundant Power supply isavailable.

    MBAS 9700

    MCU RackPSU Rack

    54

  • 8/10/2019 minilecAlarm Annunciators

    5/10

    A L A R M A N N U N C I A T O R S

    16 Pt. DFU : Small Windows

    16 Pt . DFU Big Windows 16 Pt . DFU Big Windows 16 Pt . DFU Big Windows

    Dimensional Details for Facia

    288

    14 4

    F1

    F2

    F3

    F4

    F5

    F6

    F7

    F8

    F9

    F10

    F11

    F12

    F13

    F14

    F15

    F16

    28 2

    13 816 Pts. FaciaBig Windows

    Panel Cutout

    14 4 13 8

    13 814 4 16 Pts. FaciaSmall Windows

    F1 F2 F9 F10

    F3 F4 F11 F12

    F5 F6 F13 F14

    F7 F8 F15 F16

    Panel Cutout

    COMPUTER INTERFACE

    The MCU unit transmits fault information to computer serially.

    RS232/RS485 standard is used for ser ial communicat ion.

    Communication protocol modbus ASCII / RTU can be offered. In

    computer user-friendly software is written. This software offers on-

    line Date & Time setting, Legend setting, Display window & also it

    gives fault repor t with o n demand p rinting facility.

    TECHNICAL SPECIFICATIONS:

    1.0 Supply voltage 20-60 VDC, 90 - 270VAC/DC

    2.0 Supply frequency 50 / 60 Hz. ( 3%)for AC

    3.0 Input

    3.1 Fault Alarm Inputs. Actuation Through Fault Contacts

    3.2 Fault contacts. Potential free (volt free) type

    3.3 Inpu t inter ro gatio n vo ltage + 1 2V DC( ISO)

    3.4 Input isolation Opto isolating device.(2 KV)

    3.5 Response Time 40 msec.

    3.6 Site selectable DIP for

    Fault type NO/NCGrouping Trip/Non Trip

    Sequence selection M anual/Auto/ Ring b ac k (o ptional)/ Firstup

    4.0 Output

    4.1 Output contacts 1NO+ 1NO + 1NO (optional)

    4.2 Output con tact fo r CPU & PSU fai l 1NC

    4.3 Contact Rating 5 amp at 240 VAC (Resistive)

    5.0 No. of windows 16/24/32/40/48/64/80/96/112/128

    5.1 Window s dim ensions 30 mm x 30 mm For small w indow s

    30 mm x 65 mm For big windows

    5.2 Window Colours Red/Yellow /Amber/Green/White/Blue

    5.3 Flash rates Fast f lash- 50-60 flashes / MinSlow flash - 25-30 flashes / Min.

    5.4 Pow er Consumption 1.5 W per Window. (Max)

    6.0 Sequence Manual, Auto,Ring back (optional), Firstup

    (Any Other Sequences On Request)

    7.0 Serial communication RS232/RS485 (w ith modbus ASCII/RTU)

    optional

    MBAS 9700

    55

    Note: Mention specific voltage( Fixed/wide range ) in order

  • 8/10/2019 minilecAlarm Annunciators

    6/10

    55

    EXTERNAL WIRING DIAGRAM WITH REPEAT RELAY

    COMPUTER

    CON1

    IOU-1

    CON2A

    IOU-2

    CON3A

    CON3ACON3

    DFU2

    CON3

    IOU-3

    CON4A

    IOU-4

    CON5A

    CON5ACON5

    DFU4

    CON5

    CON4ACON4

    DFU3

    CON4

    IOU-5

    CON6A

    IOU-6

    CON7A

    CON7ACON7

    DFU6

    CON7

    IOU-7

    CON8A

    IOU-8

    CON9A

    CON9ACON9

    DFU8

    CON9

    CON8ACON8

    DFU7

    CON8

    CON6ACON6

    DFU5

    CON6

    CON2ACON2

    DFU1

    CON2

    PSU-1 PSU-2 P SU -3 P SU -4

    ON ON ON ON

    MCU MODULE

    OFF OFF OFF OFF

    CON10

    PSU-5

    PSU MODULE

    CON10

    ON

    OFF

    REPEAT RELAYCARD - 1

    REPEAT RELAYCARD - 2

    REPEAT RELAYCARD - 3

    REPEAT RELAYCARD - 4

    REPEAT RELAYCARD - 5

    REPEAT RELAYCARD - 6

    REPEAT RELAYCARD - 7

    REPEAT RELAYCARD - 8

    TOMAINS

    FOR CUSTOMERFAULT INPUTS

    FFFFFFFF

    56

    A L A R M A N N U N C I A T O R S - M B A S 9 7 0 0

    MODELS MOUNTING DIMENSIONS (mm) OVERALL DIMENSIONS (mm)

    A B C D E F G

    128 POINTS 57.15 465.10 292.38 482.60 132.50 309.88

    112 POINTS 57.15 419.38 292.38 436.88 283.00 132.50 309.88

    96 POINTS 57.15 373.66 241.58 391.16 283.00 132.50 259.58

    80 POINTS 57.15 327.94 241.58 345.44 283.00 132.50 259.58

    64 POINTS 57.15 434.62 -- -- -- -- 452.12 283.00 132.50 --- -- -- -

    48 POINTS 57.15 388.90 -- -- -- -- 406.40 283.00 132.50 --- -- -- -

    40 POINTS 57.15 388.90 -- -- -- -- 406.40 283.00 132.50 --- -- -- -

    32 POINTS 57.15 292.38 -- -- -- -- 309.88 283.00 132.50 --- -- -- -

    24 POINTS 57.15 292.38 -- -- -- -- 309.88 283.00 132.50 --- -- -- -16 POINTS 57.15 246.66 -- -- -- -- 264.16 283.00 132.50 --- -- -- -

    283.00

    MODELS MOUNTING DIMENSIONS (mm) OVERALL DIMENSIONS (mm)

    A B C D E F G

    128 POINTS 57.15 465.10 393.98 482.60 132.50 411.48

    112 POINTS 57.15 419.38 393.98 436.88 283.00 132.50 411.48

    96 POINTS 57.15 373.66 292.38 391.16 283.00 132.50 309.88

    80 POINTS 57.15 327.94 292.38 345.44 283.00 132.50 309.88

    64 POINTS 57.15 327.94 241.58 345.44 283.00 132.50 259.58

    48 POINTS 57.15 439.70 -- -- -- -- 457.20 283.00 132.50 --- -- -- -

    40 POINTS 57.15 439.70 -- -- -- -- 457.20 283.00 132.50 --- -- -- -

    32 POINTS 57.15 343.18 -- -- -- -- 360.68 283.00 132.50 --- -- -- -24 POINTS 57.15 343.18 -- -- -- -- 360.68 283.00 132.50 --- -- -- -

    16 POINTS 57.15 246.66 -- -- -- -- 264.16 283.00 132.50 --- -- -- -

    283.00

    DIMENSIONAL DETAILS - MCU & PSU

    MCU & PSU for 16 to 64 w indows are housed in one 19 rack.

    20 - 60 V DC

    128

    112

    PANEL CUTOUT DETAILS - DFU

    96

    80

    FPSU

    SIDE VIEW

    E

    APSU

    FRONT VIEW

    C

    G

    FMCU

    SIDE VIEW

    E

    AMCU

    FRONT VIEW

    D

    B

    64

    48

    32

    QRQRQRQRQRQRQRQ

    24S

    16

    P

    P Q R

    Small Window 138mm 138mm 6mm

    Big Window 138mm 282mm 6mm

    W L D

    Small Windows

    Big Windows

    Overall Dimensions ( DFU )

    MODELS

    128 POINT 144m.m. 1152m.m . 70m.m.112 POINT 144m.m. 1008m.m . 70m.m.96 POINT 144m.m. 864m.m . 70m.m.80 POINT 144m.m. 720m.m . 70m.m.64 POINT 144m.m. 576m.m . 70m.m.48 POINT 144m.m. 432m.m . 70m.m .40 POINT 144m.m. 432m.m . 70m.m .32 POINT 144m.m. 288m.m . 70m.m .24 POINT 144m.m. 288m.m . 70m.m .16 POINT 144m.m. 144m.m . 70m.m .

    128 POINT 144m .m . 2304m.m. 70m.m.

    112 POINT 144m .m . 2016m.m. 70m.m.

    96 POINT 144m .m . 1728m.m. 70m.m.

    80 POINT 144m .m . 1440m.m. 70m.m.

    64 POINT 144m .m . 1152m.m. 70m.m.

    48 POINT 144m .m . 864m.m. 70m.m.40 POINT 144m.m . 720m.m . 70m.m .32 POINT 144m.m. 576m.m. 70m.m.24 POINT 144m.m. 432m.m. 70m.m.

    16 POINT 144m.m. 288m.m. 70m.m.

    24B

    7.0 mm

    10.0 mm

    -

    90 - 270 VAC/ DC

  • 8/10/2019 minilecAlarm Annunciators

    7/10

    MBAS 08

    A L A R M A N N U N C I A T O R S

    Most compact alarm Annunciator with improved window design and all major features of MBAS 0600Annunciator. Models with built -in Buzzer & Push buttons also available.

    Supply Voltage

    Supply Frequency [FOR AC]

    Windows

    Display (Window)

    Window DimensionsSmallBig

    Power Consumptions

    Flash Rate

    Operating Sequence

    Other Features

    Optional Features

    Input Signal

    Input Interrogation Voltage

    Window Colours

    Output Contacts

    Output Contact Rating

    Inbuilt Push Buttons

    Communication

    Operational Temp. Lim it

    Humidity

    Enclosure

    Unit DimensionsOverall (L x W x D)Cutout (L x W)

    Weight

    90 to 27 0 VAC/DC

    24 VDC /30 VDC /48VDC50 / 60 Hz 3%

    4 / 6 / 7 / 8 [m ax]

    Window lenses replaceableLegends replaceable.

    37 X 17 mm.37 X 27 mm. for 4 Windows m odel only

    50 - 6 0 Flash per min. in fast flashing

    20 - 30 Flash per min. in slow flashing

    S1, S2, S3, S4 (Site Selectable)

    NO / NC and Grouping (Trip/Non trip) Selection Supervisory Contact output.

    Any other operating sequence. RS232 / RS485 Output Man / Unmanned Feature. Supply fail Annunciation

    Potential Free contacts

    + 12 VD C

    Red, Green, Yellow, Amber, Blue, White.

    1 NO + 1 NO [For Hooter]1NO For Ring back or Supervisor y contact ( Optional)

    5 Amp, 24 0V AC (Resistive)

    4 NOS. (Test, Mute, Accept, Reset) Mem brane type (Optional)

    RS232 / RS485 (MODBUS RTU/ASCII) (Optional)

    -5C to 60 C

    Upto 95% Rh

    ABS moulded enclosure

    96 x 96 x 76 mm92 x 92 mm

    350gm

    1.5 Watts per Window (M ax)

    M

    A1

    U/M

    A2

    SW

    I2

    C2RLY-2

    VE~ /+

    - VE~ /

    E

    AUX. SUPPLY

    F1

    F2

    F3

    F4

    F5

    F6

    F7

    F8

    C

    TEST

    MUTE

    ACK

    RST

    C

    TPB

    RPB

    APB

    MPB

    RC N/W

    I3

    C3RLY-3 RC N/W

    I1

    C1RLY-1 RC N/W

    E

    RS 485 OUTPUT

    SR. NO. KEY OPERATION MODE OF OPERATION WINDOW STATUS WDL STATUS

    1 --- Normal Run Mode As per operation Flashing @ 1 flash/sec.

    2 TEST + ACK Sequence selection Windows Flashing @ 1 flash/sec.

    Pressed (for 5 Sec.) fast flashes for

    2 to 3 sec.

    W1 - ON - S1

    W2 - ON - S2

    W3 - ON - S3

    W4 - ON - S4

    3 TEST + ACK NO / NC selection W - ON - NO Off

    Pressed (for 5 Sec.) W - OFF- NC

    4 TEST + ACK Grouping selection W - ON - Group 1 Steady On

    Pressed (for 5 Sec.) W - OFF- Group 2

    5 TEST + ACK Device ID selection As per char t in Fast Flashing

    Pressed (for 5 Sec.) Manual

    6 Auto exit af ter 10 Seconds

    PROGRAMMING OF MBAS 08

    96

    96

    80

    96

    OVERALL DIMENSIONS

    CUT OUT DIMENSIONS

    92

    92

    CONNECTION

    DIAGR

    AM

    4 Windows PB + 2 Buzzer 6 Windows PB + 2 Buzzer 7 Windows + PB 8 Windows

    57

    Note: Mention specific voltage

    ( Fixed/wide range ) in order

  • 8/10/2019 minilecAlarm Annunciators

    8/10

  • 8/10/2019 minilecAlarm Annunciators

    9/10

  • 8/10/2019 minilecAlarm Annunciators

    10/10

    A L A R M A N N U N C I A T O R S

    The MINILEC Annunciation systems are programmed tooperate as per following operating sequences confirming to ISAstandards. Other sequences / non standard sequences are given

    as per customers requirement.

    MinilecSequence Code

    OperatingSequence Title

    ISA Std. Code

    S1 Manual Reset M1S2 Auto Reset A1S3 Ringback R1-12S4 First UP F2M-1

    P NORMAL

    V OFF

    A SILENT

    P ABNORMAL

    / NORMAL

    V STEADY

    A SILENT

    P ABNORMAL

    / TEST

    V FLASHING

    A AUDIBLEP ABNORMAL

    / NORMAL

    V FLASHING

    A SILENT

    ACCEPT

    ACCEPT

    RESET WHILENORMAL

    TO ABNORMAL

    SILENCE MUTE

    SEQUENCE S1 : Manual Reset (M1) 1. Test, Silence Accept,Reset Push Buttons areexternal.

    2. Audible alarm can besilenced by pressingSilence (Mute) Pushbutton.

    3. Manual reset of Accepted

    faults after processconditions return tonormal.

    4. Operation test provided.

    P NORMAL

    V OFF

    A SILENT

    P ABNORMAL

    V STEADY

    A SILENT

    P ABNORMAL

    / TEST

    V FLASHING

    A AUDIBLEP ABNORMAL

    / NORMAL

    V FLASHING

    A SILENT

    ACCEPT

    ACCEPT

    RETURN TONORMAL

    TO ABNORMAL

    SILENCE / MUTE

    SEQUENCE S2 : Auto Reset (A1) 1. Test, Silence Accept,Reset Push Buttons areexternal.

    2. Audible alarm can besilenced by pressingSilence (Mute) Pushbutton.

    3. Automatic reset ofAccepted faults afterprocess conditions returnto normal.

    4. Operation test provided.

    P NORMAL

    V OFF

    A OFF

    RB SILENTP ABNORMAL

    V SLOW

    FLASH

    A OFF

    RB AUDIBLE

    P ABNORMAL

    V FAST FLASH

    A AUDIBLE

    RB SILENT

    P ABNORMAL

    V STEADY

    A SILENT

    RB SILENT

    RETURNTO NORMAL

    RETURN TO NORMAL

    ACCEPT WHILENORMAL

    TO ABNORMAL

    ACCEPTWHILE ABNORMAL

    SEQUENCE S3 : Ringback (R1-12) 1. Test, Silence Accept,Reset Push Buttons areexternal.

    2. Alarm & ringback Audibledevices.

    3. Audible device orringback alarm can besilenced by pressingSilence (Mute) Pushbutton.

    4. Ringback visual &audible alarm whenprocess status returns tonormal.

    5. Operation test provided.

    RETURN TO ABNORMAL

    P NORMAL

    V OFF

    A SILENT

    P ABNORMAL

    V STEADY

    A SILENT

    P ABNORMAL

    / TEST

    V FLASHING

    A AUDIBLEP ABNORMAL

    V STEADY

    A AUDIBLEACCEPT

    MUTE

    ACCEPT (FIRST-OUT RESET)

    ACCEPT (FIRST-OUT RESET)

    RESET WHILENORMAL

    FIRST TOABNORMAL

    SILENCE / MUTE

    SEQUENCE S4 : First Out Manual Reset (F2M-1) 1. Test, Silence Accept,Reset Push Buttons areexternal.

    2. First-out flashing andsubsequent steady.

    3. Manual reset of Acceptedfaults when processstatus return to normal.

    4. Operation test provided.

    P ABNORMAL

    V FLASHING

    A SILENT

    Note:

    P :Process Status, V :Visual Alarm Status,A :Audible Alarm Status, RB :Ringback audible alarm status.

    / TEST

    SUBSEQUENT TOABNORMAL

    STANDARD OPERATING SEQUENCES

    Repeat Relay Card

    External Repeat Relay Cards can be connected for remote annunciation or

    interfacing with SCADA or DCS hardware. These cards are connected byplug- in type pre-fab c ables. Repeat Relay Card is suitable for NO type Fault

    contacts o nly.

    4- 3.0

    25

    85

    180

    50

    5

    190

    510

    Manned / Unmanned Facility

    This feature allows disabling the audio

    & visual indication on fault occ urrence ift h e s t a t i o n i s u n m a n n e d . T h e

    annunciator registers & records all

    faults occurring during unmanned

    mode and displays again manned

    mode.

    M

    A1

    U/M

    A2

    S

    RS 232 / 485 Convertor

    This is a universal convertor for conver ting RS 232 serial

    por t to RS 485 serial port or vice versa. It operates on 2 30

    AC supply and is to be used with Minilec make

    interconnecting cables for Minilec annunciators & for PC.

    Electronic / Industrial Hooter

    Electronic Hooters w ith tone & volume c ontrol are supplied. Suitable for

    AC or DC supply Standard 96 x 9 6 enclosure.

    OPTIONAL ACCESSORIES

    ANNUNCIATOR PANELS

    60

    Often Alarm Annunciators are required to be housed in a suitablecubical and many tim es such control panel consists of only Alarm Annunciators.Minilec offers Alarm Annu nciators along with contro l panels. This includes design ofcontrol panel, fabrication, painting, assembly of Alarm Ann unciators and assistanceduring installation and c omm issioning.Retrofitting work by replacing old annunciation system with latest design and forexpansion in power stations, substations, process plants as also standardAnnunciation Panels for plants and equipments c an be catered to.

    The Minilec Panel Advantages Complete in-house design, assembly

    of Annunci ator Panels.

    Sof tware capabi li ty for automisat ionto meet project specification s.

    Component layout as per standards &safety requirements.

    Powder coa ted MS or A luminum RackPanels with quality panel wiring.