MINI FREESTANDING · Low-H²O technology cuts energy consumption without reducing output Designed...
Transcript of MINI FREESTANDING · Low-H²O technology cuts energy consumption without reducing output Designed...
MINI FREESTANDING strikingly discreet
Low-H²O technology cuts energy consumption without reducing output
Designed to fit unobtrusively in front of glazed facades
Versatile range of options available to convert the Mini Freestanding into a bench or wall-mounted heater
Powerful and unobtrusive, the Mini Freestanding is ideal for use in
refurbishment projects where trench heating is not practical:
Large glazed areasRetail
Offices
Option to hide all connections within the Mini Freestanding’s feet
www.jaga.co.uk
Height
Width
Type
Length
600 700 800 900 1000 1100 1200 1400 1600 1800 2000 2200 2400 2600 2800 3000
80 130 09 255 298 340 383 425 468 510 595 680 765 850 935 1020 1105 1190 1275
180 14 416 486 555 625 694 763 833 972 1110 1249 1388 1527 1666 1804 1943 2082
230 19 572 667 762 858 953 1048 1144 1334 1525 1715 1906 2097 2287 2478 2668 2859
130 80 05 197 230 263 296 329 362 395 461 526 592 658 724 790 855 921 987
130 10 303 354 404 455 505 556 606 707 808 909 1010 1111 1212 1313 1414 1515
180 15 508 593 678 762 847 932 1016 1186 1355 1525 1694 1863 2033 2202 2372 2541
230 20 717 837 956 1076 1195 1315 1434 1673 1912 2151 2390 2629 2868 3107 3346 3585
230 80 06 323 377 431 485 539 593 647 755 862 970 1078 1186 1294 1401 1509 1617
130 11 601 701 802 902 1002 1102 1202 1403 1603 1804 2004 2204 2405 2605 2806 3006
180 16 785 916 1046 1177 1308 1439 1570 1831 2093 2354 2616 2878 3139 3401 3662 3924
230 21 1021 1191 1361 1531 1701 1871 2041 2381 2722 3062 3402 3742 4082 4423 4763 5103
280 80 06 342 399 456 513 570 627 684 798 912 1026 1140 1254 1368 1482 1596 1710
130 11 653 762 871 980 1089 1198 1307 1525 1742 1960 2178 2396 2614 2831 3049 3267
180 16 860 1003 1146 1290 1433 1576 1720 2006 2293 2579 2866 3153 3439 3726 4012 4299
230 21 1127 1315 1503 1691 1879 2067 2255 2631 3006 3382 3758 4134 4510 4885 5261 5637
All dimensions in millimetres.
Correction Factor Equations
Mini Freestanding
Outputs in watts at 75/65/20°C, in accordance with EN442
Outputs
Q = Total heat emitted by unit (kW)m = Water mass flow rate (kg/s)Cp = Specific heat capacity (4.187 kJ/kg °C) Approximate
Q Equation 2: m = (TF – TR) x Cp
TF = Water flow temperature °CTR = Water flow return temperature °Camb = Ambient temperature °C
TF + TR Equation 1: ∆T = - amb 2
Correction Factor Equations
Equation to determine the mean water temperature difference, minus ambient air (∆T)
Equation to determine water mass flow rate (m)
www.jaga.co.uk
TF TL TR
40 45 50 55 60 65 70 7580 20 0.74 0.80 0.87 0.93 1.00 1.07 1.14 1.21 24 0.64 0.70 0.76 0.83 0.89 0.96 1.03 1.1075 20 0.68 0.74 0.80 0.87 0.93 1.00 1.07 24 0.58 0.64 0.70 0.76 0.83 0.89 0.9670 20 0.62 0.68 0.74 0.80 0.87 0.93 24 0.52 0.58 0.64 0.70 0.76 0.8365 20 0.56 0.62 0.68 0.74 0.80 24 0.47 0.52 0.58 0.64 0.7060 20 0.50 0.56 0.62 0.68 24 0.41 0.47 0.52 0.5855 20 0.44 0.50 0.56 24 0.36 0.41 0.4750 20 0.39 0.44 24 0.31 0.3645 20 0.34 24 0.26
The indicated outputs ∆T 50 °C are the exact outputs and are measured in accordance with EN 442. An average correction factor is given in this table for outputs at other ∆T and is applicable for all dimensions. For comprehensive correction factors table see page 82.
Outputs at 75/65/20°C, average correction factors measured in accordance with EN442
Correction Factors
Mini Freestanding
Traffic white Sandblast grey metalic
133 001
For the complete Jaga colour range, see page 95.
Colours
KEYTF = Flow temperature °C
TR = Return temperature °CTL = Desired air temperature °C
www.jaga.co.uk
Easy access grille for maintenance
Strong, reliable design
A range of fixed and adjustable feet availablesee opposite page
Jaga Low-H²O heat exchangerScratch-resistant finish
Wide range of colours available
100
tes 1
From 600mm to 1600mm: minimum 2 setsFrom 1800mm to 3000mm: minimum 3 setsBench not supplied
For easy cleaning of the underside of the Low-H²O heat exchanger without detaching the casing.
100
tes 1
Mini Freestanding
Bench mounting set
Options
Brush
www.jaga.co.uk
Height 80mm
FS
AS/AL
FM/FL
DD1
H
2.5
7.5
hh1
d1d
65 100120
150 150
L 7565
3550
215
> 340
135
> 210
Key:
FS = Feet short : 65mmFM = Feet medium : 100mmFL = Feet long : 120mmAS = Adjustable feet short : 135mm > 210mmAL = Adjustable feet long : 215mm > 340mm
In units 1800mm or longer, 3 feet will be included as standard.
Type D D1 d d1 h* h1*
9 130 135 65 70 50 50
14 180 185 90 95 70 70
19 230 235 115 120 90 90
* Smaller dimensions can decrease output.
Type D D1 d d1 h* h1*
5/6 80 85 40 45 50 50
10/11 130 135 65 70 70 70
15/16 180 185 90 95 90 90
20/21 230 235 115 120 110 110
* Smaller dimensions can decrease output.
The valve bodies and connections offered by Jaga are totally concealed within the standard casing. Other valves may be partially visible.For detailed info, see connection sets and valves on pages 66-69.
FS
FM/FL
AS/AL
8
2.5
hh1
DD1
d1d
43
150
65 100120
L 7565
35
150
215
> 340
135>
210
D1 h
Dimensions
Heights 130mm, 230mm and 280mm
Mini Freestanding
www.jaga.co.uk
-Special feet with cover plate -Special feet with cover plate and cut-out for the thermostatic head -Rotating grille end for servicing fully integrated valve -Slanted top grille -Special configurations with heat exchangers for continuous construction, with two-sided connection -Non standard positioning of the feet -Non standard dimensions -Protective packaging for use on site -Non standard Jaga RAL colours -Special feet for raised floors on request
57L
Special feet with cover plate and cut-out for the thermostatic head
Concealed connections Cover rosette for fixed and adjustable feet
Rotating grille end for servicing fully integrated valve
Special feet with cover plate
Slanted top grille
Special Options
Mini Freestanding
www.jaga.co.uk
H
4080 40
80
40130
40130
11/01/9 epyT 6/5 epyT
12/02/91 epyT 61/51/41 epyT
H
8080
epyT epyT epyT epyT 12/02/91 61/51/41 11/01/9 6/5
Number of feet for casing length:From 600mm to 1600mm : 2 feetFrom 1800mm to 3000mm: 3 feet
Number of feet for casing length:From 600mm to 1600mm: 2 feetFrom 1800mm to 3000mm: 3 feet
L
54
2012
M
ø15
-Two-piece rosette -Strong ABS synthetic material -Simple mounting or removing by means of a click system -Heat resistance up to 100°C -White RAL 9010 -Rosette under feet
L M
100mm 38mm
112mm 50mm
Covering Rosette
Feet
Mini Freestanding
www.jaga.co.uk
Casing:
Shall be one piece, manufactured from 1.25mm thick galvanized double profile steel plate. It shall be supplied complete with fixed or adjustable feet of the specified height. The following options shall also be available: box section feet with cover plate and cut-out for TRV head and cover rosettes for the feet. Other options shall be as specified.The top grille shall be formed from 0.8mm thick galvanized double profile steel plate, with backwards angled profile.The casing and grille shall be finished with a lacquered finish to the specified colour. The coating shall be a scratch resistant, epoxy polyester powder, which is sprayed electrostatically and baked at a temperature of 200°C. It shall be UV-resistant to ASTM G53.
Heat Exchanger:
Shall be manufactured from seamless copper tubes, fitted with aluminium fins. The fins shall provide high contact area to the tubes, guaranteeing optimum efficiency across a wide range of flow and return water temperatures. The heat exchanger shall be complete with 2No. brass 1/2” BSP connections. Generally these shall be same end connections except where specified to the alternative, and be suitable for left- or right-hand installation. The complete heat exchanger assembly shall be non-corrosive and the whole assembly shall be electrostatically lacquered with dirt repellant and dust proof anthracite grey epoxy polyester lacquer RAL 7024-gloss degree 70%. The heat exchanger shall be supplied complete with 1/8” BSP air vent and 1/2” BSP drain cock, and the whole assembly to be pressure tested to 20 bar, with a maximum working pressure of 10 bar.The element shall be of sufficient quality to be provided with the manufacturer’s 30 year guarantee.
Product Specifications
Mini Freestanding
MINI FREESTANDING DBE
performance on demand
Ideal for refurbishment projects where trench heating is not practical
Low-H²O technology cuts energy consumption without reducing output,
while all connections can be hidden within the Mini Freestanding DBE's adjustable
feet
Designed to fit unobtrusively underneath large windows, the Mini Freestanding DBE
provides maximum heat from the smallest of appliances and remains operationally
quiet even at the highest outputs
Perfect for low flow temperature heating systems, the Mini Freestanding DBE is ideal for:
Large glazed areasRetailOfficesSchools and universities
www.jaga.co.uk 6160
Sound pressure and correction factors Combined sound level of multiple DBE units
Mini Freestanding DBE
1 4 8 12 16 20 24 28 32 36 40
0
2
4
6
8
10
12
14
16
Incr
ease
of s
ound
pre
ssur
e dB
(A)
Number of fan modules
Type dB(A)
Comfort Boost
11 29 35
16 27 31
Height
Type
Length
810 1010 1210 1410 1810 2410
280 11 watt standby 871 1089 1307 1525 1960 2614
watt comfort 1021 1389 1607 1975 2560 3514
watt boost 1121 1589 1807 2275 2960 4114
16 watt standby 1146 1433 1720 2006 2579 3439
watt comfort 1396 1933 2200 2756 3579 4939
watt boost 1496 2133 2420 3056 3979 5539
All dimensions in millimetres. See correction factor table opposite for other general conditionsFor an explanation of standby, comfort and boost refer to Product Specifications on page 63.
Correction Factor Equations
Outputs in watts at 75/65/20°C, calculated in accordance with EN442Outputs
Acoustic Data
Q = Total heat emitted by unit (kW)m = Water mass flow rate (kg/s)Cp = Specific heat capacity (4.187 kJ/kg °C) Approximate
Q Equation 2: m = (TF – TR) x Cp
TF = Water flow temperature °CTR = Water flow return temperature °Camb = Ambient temperature °C
TF + TR Equation 1: ∆T = - amb 2
Correction Factor Equations
Equation to determine the mean water temperature difference, minus ambient air (∆T)
Equation to determine water mass flow rate (m)
NumberdB(A)
CorrectiondB(A)
2 +3.0
3 +4.8
Several appliances with an equal sound level in a room
P2 = P1 + 10 log nP1 = sound level one applianceP2 = sound level to be calculatedn = number of appliances
Through the DBE-communication software (DBED) it is possible to set up other activator speeds. In this way you can obtain other outputs and sound pressures. For more information, contact Jaga.
www.jaga.co.uk 6160
TF TL TR
30 35 40 45 50 55 60 65 7080 20 0.70 0.75 0.80 0.85 0.90 0.95 1.00 1.05 1.10 24 0.62 0.67 0.72 0.77 0.82 0.87 0.92 0.97 1.0275 20 0.65 0.70 0.75 0.80 0.85 0.90 0.95 1.00 1.05 24 0.57 0.62 0.67 0.72 0.77 0.82 0.87 0.92 0.9570 20 0.60 0.65 0.70 0.75 0.80 0.85 0.90 0.95 24 0.52 0.57 0.62 0.67 0.72 0.77 0.82 0.8765 20 0.55 0.60 0.65 0.70 0.75 0.80 0.85 24 0.47 0.52 0.57 0.62 0.67 0.72 0.7760 20 0.50 0.55 0.60 0.65 0.70 0.75 24 0.42 0.47 0.52 0.57 0.62 0.6755 20 0.45 0.50 0.55 0.60 0.65 24 0.37 0.42 0.47 0.52 0.5750 20 0.40 0.45 0.50 0.55 24 0.32 0.37 0.42 0.4745 20 0.35 0.40 0.45 24 0.27 0.32 0.3740 20 0.30 0.35
24 0.22 0.27
The indicated outputs ∆T 50 °C are the exact outputs and are calculated in accordance with EN 442. An average correction factor is given in this table for outputs at other ∆T and is applicable for all dimensions. For comprehensive correction factors table see page 83.
Outputs at 75/65/20°C, average correction factors calculated in accordance with EN442
Traffic white Sandblast grey metalic
133 001
Colours
Correction Factors
Mini Freestanding DBE
KEYTF = Flow temperature °C
TR = Return temperature °CTL = Desired air temperature °C
www.jaga.co.uk 6362
Jaga Comap valve to the floor -Complete casing in colour 133 traffic white or 001 sandblast grey metallic
-Fully pre-assembled product
-Jaga thermostatic valve and extension pipe with 1/2” connections at the bottom of the foot, left or right
-Sleeve couplings
-DBE system complete with 240 volts AC/ 12 volts DC power, control and operation
-Twin Low-H²O heat exchanger
-Removable grille
-Feet with pipe guard
-Straight air vent 1/8”
H280
125 195
L 80W
D110
80 220VAC
150
3550
50
125
30
d
220V AC
-Female connector to be provided in the foot.
-240 volts AC/12 volts DC power supply transformer plug is supplied.
-Socket outlet to be provided adjacent to the radiator.
Slimline profile, powerful output
FeetConceal connections
Dynamic Boost Effect (DBE) fan unitJaga Low-H²O heat exchanger
Wide range of colours available Scratch-resistant finish
Sleeve couplings, thermostatic head and H-piece: see connection accessories.
Mini Freestanding DBE
Supplied as Standard Connections
d = 65mm for type 1190mm for type 16
www.jaga.co.uk 6362
Casing:
Shall be one piece, manufactured from 1.25mm thick galvanized double profile steel plate. It shall be supplied complete with fixed or adjustable feet of the specified height. The following options shall also be available: box section feet with cover plate and perforation for TRV head and cover rosettes for the feet. Other options shall be as specified.The top grille shall be formed from 0.8mm thick galvanized double profile steel plate, with backwards angled profile.The casing and grille shall be finished with a lacquered finish to the specified colour. The coating shall be a scratch resistant, epoxy polyester powder, which is sprayed electrostatically and baked at a temperature of 200°C. It shall be UV resistant to ASTM G53.
Heat Exchanger:
Shall be manufactured from seamless copper tubes, fitted with aluminium fins. The fins shall provide high contact area to the tubes, guaranteeing optimum efficiency across a wide range of flow and return water temperatures. The heat exchanger shall be complete with 2No. brass1/2” BSP connections. Generally these shall be same end connections except where specified to the alternative, and be suitable for left- or right-hand installation. The complete heat exchanger assembly shall be non-corrosive and the whole assembly shall be electrostatically lacquered with dirt repellent and dust proof anthracite grey epoxy polyester lacquer RAL 7024 - gloss degree 70%. The heat exchanger shall be supplied complete with 1/8” BSP air vent and 1/2” BSP drain cock, and the whole assembly to be pressure tested to 20 bar, with a maximum working pressure of 10 bar.The element shall be of sufficient quality to be provided with the manufacturer’s 30 year guarantee.
Fan Unit:
The unit shall be complete with one or more fan activator sections. The sections shall be powered by a 12 volt DC supply via a dedicated 240 volt power supply transformer plug. Multiple units shall be connected to the low voltage supply with suitable connecting cables. Control of the fan activators shall be modulating fan speed dependent on measured space temperature against the control set point. The speed shall be able to be adjusted automatically from the comfort setting (67% of maximum) to zero when the temperature set point is reached.
A manual boost override facility shall also be included to allow the fan to run at 100% for a user-definable period. Temperature control shall be by means of a microprocessor circuit board fixed to the heat exchanger. The circuit board shall be complete with a range of user-definable temperature set points together with a surface contact temperature sensor to provide low water temperature hold off control of the fan.
Product Specifications
Mini Freestanding DBE
64