Mid Rise Sigma Ascensores
-
Upload
ibor-omar-castro-rosario -
Category
Documents
-
view
108 -
download
2
Transcript of Mid Rise Sigma Ascensores
MID RISE
Distributed Inverter Elevator
Di enhancing the value of the building…
Di ensuring perfect safety & reliability
Di providing ride comfort
Di maximizing energy & space saving
Di furnishing modern & universal design
Truly your elevator partner
The Changwon Factory in Korea which isreferred as the single largest elevatorplant provides one-stop manufacturingof high quality
∙Annual production Capacity(as of 2005)
- Elevator : 15,000 units
- Escalator : 700 units
The Changwon Factory
∙Established in 1995
∙10 aesthetic designers(as of 2005)
∙Accumulated Sales(as of 2005)
- over 150,000 units
The Design Center in Korea providesperfect customer satisfaction by meetingany customer needs
SIGMA has been serving you in morethan 70 countries around the world forover 35 years
The Design Center SIGMA in the world
04 SIGMA Elevator
SIGMA Elevator company’s number one priority is safety. Our basic spirit to ensure safetyis through control technology such as ‘back-up solution, safety drive operation’ andmore than 10 other safety devices.
We execute more than 30 kinds of reliability tests. These intense quality assuranceprograms make fool-proof products from design stage.
Through SIGMA Net which monitors elevator, escalator and movingwalks by internet-based software, our elevator not only provides a comprehensive and easy-to-use interfacebut also brings perfect quality to reality.
Safety & Reliability
EMI Test(Electro Magnetic Interference)
Vibration and Dropping Test
ESD Test(Electro Static Discharge)
Burst Test
05MID RISE
Distributed Inverter(Di) control drastically improves reliabilityand performance of elevators. By adopting Di control, thecontrol panel size has been reduced by 46% not to mentionwiring and installation time. The formation of high efficiencyand compactness allows the traction machine to save energy by50% and provide installation space.
SIGMA’s sophisticated, state-of-the-art ‘fuzzy logic’ reduceswaiting time and enhances performance efficiency at aparticular moment, depending on its location, direction, loadand the overall passenger calls currently on the system. SIGMA’smodern microprocessor technology can be used to optimizegroup performance to satisfy high customer standards.
SIGMA provides best-in-class ride quality on every lift we install.High switching speed of power device in the drive(IGBT) reducesmotor noise. Moreover, door operator with VVVF controlensures silent door movement. The result of moderntechnology allows SIGMA to reduce vibration and noise to aminimum level.
Customers define luxury as a swift, smooth and silent ride. Ourseamless interface between tenant requirements and elevatorperformance meets the exact standards and higher expectationof customers.
Ride Comfort
Energy & Space Saving
06 SIGMA Elevator
SIGMA Elevator company has a ‘Design Center’ forcreative and innovative product development to meetthe various needs of customers.
Our newly released ceiling and fixture fully containsbrightness and luxury which represent the latest trend.
SIGMA believes there is no boundary in usage of theelevator. This kind of belief not only enhances theexternal finish of elevator but also enriches the essenceof human life. We proudly recommend everyone toexperience our innovative design and wide assortmentswith all your senses.
Universal Design
07MID RISE
Newly designed round buttons
offer attractive shape and distinctive feelings
Thickness of handrail
provides comfortable rest and stability
OPB with tactile buttons
enables the handicapped to easily recognize
Fixture installed at proper height
allows children to free access
08 SIGMA Elevator
Natural Modern
more than 1000kg
less than 900kg
Ceiling C-NS1
OPB CBM-22C
Wall STS Hairline Etching(EW2-071)
Door STS Hairline Etching(EH1-071)
Handrail HR-04
Floor Deco Tile
※The images listed on this catalog may be different from actual products.
09MID RISE
Ceiling C-NS2
OPB CBM-22C
Wall STS Hairline Etching (EW2-067)
Door STS Hairline Etching (EH1-067)
Handrail HR-04
Floor Deco Tile
Royal Modern
more than 1000kg
less than 900kg
10 SIGMA Elevator
Techno Modern
more than 1000kg
less than 900kg
Ceiling C-NS3
OPB CBM-22C
Wall STS Hairline Etching (EW2-060)
Door STS Hairline Etching (EH1-060)
Handrail HR-04
Floor Deco Tile
11MID RISE
Contemporary Modern
Ceiling C-NL1
OPB CBM-22
CPI CID-11
Wall STS Hairline Etching (EW2-064) + STS Hairline
Door STS Hairline Etching (EH1-064)
Handrail HR-04
Floor Deco Tile
more than 1000kg
less than 900kg
Entrance
12 SIGMA Elevator
�Jamb : Narrow Jamb in Painted Steel Sheet (No. LGM-922)
�Door : Painted Steel Sheet (No. LGM-922)
�Sill : Extruded Hard Aluminum
�Hall Indicator & Hall Button : VID-M652
�
�
�
�
�
�
�Jamb : Wide Taper Jamb in STS Hairline
�Door : STS Hairline Etching (No. EH1-064)
�Sill : Extruded Hard Aluminum
�Hall Indicator & Hall Button : VID-M652
�Jamb : Wide Taper Jamb with Transom Panel in STS Hairline
�Door : STS Hairline Etching (No. EH1-067)
�Sill : Extruded Hard Aluminum
�Hall Indicator : HID-A122
�Hall Button : HBM-R45
Ceiling
Mixture of classic and modern design with sensuous
illumination enjoying comforts of natural lights inside
the elevators
13MID RISE
Standard
C-NS2(Painted steel sheet color No.LGM-924+LGM-920)
C-NS1(Painted steel sheet color No.LGM-924+LGM-920)
C-HX3(Painted steel sheet color No.LGM-922)
C-HX2(Painted steel sheet color No.LGM-922)
Option
C-NL1(Painted steel sheet color No.LGM-924+Stainless Mirror)
C-NS3(Painted steel sheet color No.LGM-924+LGM-920)
14 SIGMA Elevator
Fixture & Colors
VID-M652VID-M652T
OPB Hall Button
Handicapped OPB
HBM-R45
VID-M632HBM-S43
CBM-22C
OPB Hall Button
Handicapped OPB
CBM-13C CBM-42SH
VID-M632T
CBM-44SH
15MID RISE
Handrails
HID-A122
Car Position Indicators
CID-10 CID-12
HID-C132
HID-A132
HR-02
HR-04
HR-08
Hall Position Indicators (Horizontal Type)
Painted Steel Sheet Color
�Actual colors may be different from these prints.
LGM-921 LGM-922 White Pearl LGM-920 LGM-930 LGP-928 LGP-004
LGP-944 LGP-924 LGP-923 LGP-015 LGP-925 LGP-943 LGP-934
LGP-927
Etching Patterns
16 SIGMA Elevator
EW2-060EH1-060
Etching Patterns
EW2-043EH1-043
EW2-062EH1-062
EW2-063EH1-063
EW2-064EH1-064
EW2-067EH1-067
EW2-069EH1-069
EW2-070EH1-070
EW2-071EH1-071
EW2-072EH1-072
EW2-074EH1-074
EW2-075(BR)EH1-075(BR)
EW2-076EH1-076
EW2-077EH1-077
EW3-001EH2-001
EW3-003EH4-003
EW3-031EH2-031
EW4-005EH3-005
EW4-034EH3-034
EW6-028EH3-028
17MID RISE
Passenger Elevator Layouts
Technical Data
Hoistway & Machine Room Plan(Simplex)
Note1. ※(Separating Beams) : By Others
2. Unit : mm
Hoistway & Machine Room Plan(Duplex)
Hoistway Section
Technical Data
Technical Data
18 SIGMA Elevator
Items
Overhead
PitDepth
Machine roomHeight
60L≤1020
L > 1020
L≤1020
L > 1020
L≤1020
L > 1020
L≤1020
L > 1020
L≤1020
L > 1020
L≤1020
L > 1020
L≤1020
L > 1020
4550
4600
4750
4800
4950
5000
1500
1600
1800
1800
2100
2100
2200
2400
4400
4400
4450
4600
4600
4750
1450
1550
1500
1600
1700
1950
2200
2400
4200
4250
4400
4450
4600
4650
1450
1600
1550
1700
1800
1950
2500
2850
4200
4250
4400
4450
4600
4650
1450
1550
1600
1700
1700
1850
2200
2400
90
105
60
90
105
60,90,105
Speed(m/min)
Load(kg)
Code / Country
Standard SingaporeMalaysiaEN Code
Overhead, Pit Depth & Machine Room Height
(Unit : mm)
(Unit : mm)
Items
Overhead
PitDepth
Machine roomHeight
120
150
5500
5700
2100
2400
2400
2400
5200
5400
2000
2400
2400
2400
5200
5400
2100
2500
2850
2850
120
150
120
150
Speed(m/min)
Code / Country
Standard SingaporeMalaysia
5200
5400
2100
2500
2400
2400
EN Code
19MID RISE
Planning Guide For Dimensions | Di1 (60 m/min)
Malaysia, Singapore
Standard
EN Code
(Unit : mm)
60
450
550
600
680
750
900
1000
1150
1350
1600
800
800
800
800
800
900
900
1000
1100
1000
1100
1100
1400×850
1400×1030
1400×1100
1400×1250
1400×1350
1600×1350
1600×1500
1800×1500
2000×1350
1800×1700
2000×1500
2000×1750
2150×1600
1450×1015
1450×1195
1450×1265
1450×1415
1450×1515
1650×1515
1650×1665
1890×1685
2090×1535
1890×1885
2090×1685
2090×1935
2240×1785
1800
1800
1800
1800
1800
2000
2000
2400
2600
2400
2600
2600
2750
1450
1630
1700
1850
1950
1950
2100
2200
2050
2400
2200
2450
2300
3750
3750
3750
3750
3750
4150
4150
4950
5350
4950
5350
5350
5650
1450
1630
1700
1850
1950
1950
2100
2200
2050
2400
2200
2450
2300
2100
2100
2100
2100
2100
2300
2300
2700
2900
2700
2900
2900
3050
3200
3400
3500
3650
3750
3750
3900
4000
3850
4200
4000
4250
4100
4100
4100
4100
4100
4100
4500
4500
5300
5700
5300
5700
5700
6000
3200
3400
3500
3650
3750
3750
3900
4000
3850
4200
4000
4250
4100
3600
4050
4100
4200
4550
5100
5450
8000
8000
8900
8900
10200
10200
2000
2500
2500
2800
2900
3800
4300
5200
5200
6000
6000
7000
7000
3800
4550
4700
5000
5200
6300
6600
9550
10150
10900
3150
3350
3450
3600
3750
4500
4700
7150
7500
8700
Speed(m/min) Person Load(kg)
EntranceOpening
(mm)Inside
AN×BN
Outside
AS×BS AH BH AH BH R1 R2 R3 R4
Car Size Hoistway Size Machine Room Reaction Load(kg)Simplex Duplex
Capacity Pit ReactionLoad(kg)
AM BM AM BM
Machine Room Size
Simplex Duplex
6
8
9
10
11
13
15
17
20
24
(Unit : mm)
60
450
550
610
680
750
900
1020
1155
1360
1565
800
800
800
800
800
900
900
1000
1100
1000
1100
1100
1400×820
1400×1030
1400×1150
1400×1250
1400×1350
1600×1350
1600×1550
1800×1500
2000×1350
1800×1750
2000×1550
2000×1750
2150×1600
1450×985
1450×1195
1450×1315
1450×1415
1450×1515
1650×1515
1650×1715
1890×1685
2090×1535
1890×1935
2090×1735
2090×1935
2240×1785
1800
1800
1800
1800
1800
2000
2000
2400
2600
2400
2600
2600
2750
1420
1630
1750
1850
1950
1950
2150
2200
2050
2450
2250
2450
2300
3750
3750
3750
3750
3750
4150
4150
4950
5350
4950
5350
5350
5650
1420
1630
1750
1850
1950
1950
2150
2200
2050
2450
2250
2450
2300
2100
2100
2100
2100
2100
2300
2300
2700
2900
2700
2900
2900
3050
3170
3400
3550
3650
3750
3750
3950
4000
3850
4250
4050
4250
4100
4100
4100
4100
4100
4100
4500
4500
5300
5700
5300
5700
5700
6000
3170
3400
3550
3650
3750
3750
3950
4000
3850
4250
4050
4250
4100
3600
4050
4100
4200
4550
5100
5450
8000
8000
8900
8900
10200
10200
2000
2500
2500
2800
2900
3800
4300
5200
5200
6000
6000
7000
7000
3800
4550
4700
5000
5200
6300
6600
9550
10150
10900
3150
3350
3450
3600
3750
4500
4700
7150
7500
8700
Speed(m/min) Person Load(kg)
EntranceOpening
(mm)Inside
AN×BN
Outside
AS×BS AH BH AH BH R1 R2 R3 R4
Car Size Hoistway Size Machine Room Reaction Load(kg)Simplex Duplex
Capacity Pit ReactionLoad(kg)
AM BM AM BM
Machine Room Size
Simplex Duplex
6
8
9
10
11
13
15
17
20
23
(Unit : mm)
60
450
525
600
675
800
900
1000
1200
1350
1600
800
800
800
800
800
900
900
1000
1100
1000
1100
1100
1400×850
1400×1030
1400×1100
1400×1250
1400×1350
1600×1350
1600×1500
1800×1500
2000×1350
1800×1700
2000×1500
2000×1750
2150×1600
1450×1015
1450×1195
1450×1265
1450×1415
1450×1515
1650×1515
1650×1665
1890×1685
2090×1535
1890×1885
2090×1685
2090×1935
2240×1785
1800
1800
1800
1800
1800
2000
2000
2400
2600
2400
2600
2600
2750
1450
1630
1700
1850
1950
1950
2100
2200
2050
2400
2200
2450
2300
3750
3750
3750
3750
3750
4150
4150
4950
5350
4950
5350
5350
5650
1450
1630
1700
1850
1950
1950
2100
2200
2050
2400
2200
2450
2300
2100
2100
2100
2100
2100
2300
2300
2700
2900
2700
2900
2900
3050
3200
3400
3500
3650
3750
3750
3900
4000
3850
4200
4000
4250
4100
4100
4100
4100
4100
4100
4500
4500
5300
5700
5300
5700
5700
6000
3200
3400
3500
3650
3750
3750
3900
4000
3850
4200
4000
4250
4100
3600
4050
4100
4200
4550
5100
5450
8000
8000
8900
8900
10200
10200
2000
2500
2500
2810
2900
3800
4300
5200
5200
6000
6000
7000
7000
3800
4550
4700
5000
5200
6300
6600
9550
10150
10900
3150
3350
3450
3600
3750
4500
4700
7150
7500
8700
Speed(m/min) Person Load(kg)
EntranceOpening
(mm)Inside
AN×BN
Outside
AS×BS AH BH AH BH R1 R2 R3 R4
Car Size Hoistway Size Machine Room Reaction Load(kg)Simplex Duplex
Capacity Pit ReactionLoad(kg)
AM BM AM BM
Machine Room Size
Simplex Duplex
6
7
8
9
10
12
13
16
18
21
20 SIGMA Elevator
Technical Data
Planning Guide For Dimensions | Di1 (90,105 m/min)
Standard(Unit : mm)
90
105
550
600
680
750
900
1000
1150
1350
1600
800
800
800
800
900
900
1000
1100
1000
1100
1100
1400×1030
1400×1100
1400×1250
1400×1350
1600×1350
1600×1500
1800×1500
2000×1350
1800×1700
2000×1500
2000×1750
2150×1600
1450×1195
1450×1265
1450×1415
1450×1515
1650×1515
1650×1665
1890×1685
2090×1535
1890×1885
2090×1685
2090×1935
2240×1785
1800
1800
1800
1800
2000
2000
2400
2600
2400
2600
2600
2750
1630
1700
1850
1950
1950
2100
2200
2050
2400
2200
2450
2300
3750
3750
3750
3750
4150
4150
4950
5350
4950
5350
5350
5650
1630
1700
1850
1950
1950
2100
2200
2050
2400
2200
2450
2300
2100
2100
2100
2100
2300
2300
2700
2900
2700
2900
2900
3050
3400
3500
3650
3750
3750
3900
4000
3850
4200
4000
4250
4100
4100
4100
4100
4100
4500
4500
5300
5700
5300
5700
5700
6000
3400
3500
3650
3750
3750
3900
4000
3850
4200
4000
4250
4100
4200
4500
4900
5250
5750
6150
9400
9400
10000
10000
11550
11550
2800
3100
3400
3700
4100
4600
7750
7750
8250
8250
8700
8700
6550
6850
7450
7850
9000
9650
14100
15400
16950
4800
5000
5350
5550
6250
6650
10400
11150
12000
Speed(m/min) Person Load(kg)
EntranceOpening
(mm)Inside
AN×BN
Outside
AS×BS AH BH AH BH R1 R2 R3 R4
Car Size Hoistway Size Machine Room Reaction Load(kg)Simplex Duplex
Capacity Pit ReactionLoad(kg)
AM BM AM BM
Machine Room Size
Simplex Duplex
8
9
10
11
13
15
17
20
24
Malaysia, Singapore(Unit : mm)
90
105
550
610
680
750
900
1020
1155
1360
1565
800
800
800
800
900
900
1000
1100
1000
1100
1100
1400×1030
1400×1150
1400×1250
1400×1350
1600×1350
1600×1550
1800×1500
2000×1350
1800×1750
2000×1550
2000×1750
2150×1600
1450×1195
1450×1315
1450×1415
1450×1515
1650×1515
1650×1715
1890×1685
2090×1535
1890×1935
2090×1735
2090×1935
2240×1785
1800
1800
1800
1800
2000
2000
2400
2600
2400
2600
2600
2750
1630
1750
1850
1950
1950
2150
2200
2050
2450
2250
2450
2300
3750
3750
3750
3750
4150
4150
4950
5350
4950
5350
5350
5650
1630
1750
1850
1950
1950
2150
2200
2050
2450
2250
2450
2300
2100
2100
2100
2100
2300
2300
2700
2900
2700
2900
2900
3050
3400
3550
3650
3750
3750
3950
4000
3850
4250
4050
4250
4100
4100
4100
4100
4100
4500
4500
5300
5700
5300
5700
5700
6000
3400
3550
3650
3750
3750
3950
4000
3850
4250
4050
4250
4100
4050
4100
4200
4550
5100
5450
8000
8000
8900
8900
10200
10200
2500
2500
2800
2900
3800
4300
5200
5200
6000
6000
7000
7000
6550
6850
7450
7850
9000
9650
14100
15400
16950
4800
5000
5350
5550
6250
6650
10400
11150
12000
Speed(m/min) Person Load(kg)
EntranceOpening
(mm)Inside
AN×BN
Outside
AS×BS AH BH AH BH R1 R2 R3 R4
Car Size Hoistway Size Machine Room Reaction Load(kg)Simplex Duplex
Capacity Pit ReactionLoad(kg)
AM BM AM BM
Machine Room Size
Simplex Duplex
8
9
10
11
13
15
17
20
23
EN Code(Unit : mm)
90
105
525
600
675
800
900
1000
1200
1350
1600
800
800
800
800
900
900
1000
1100
1000
1100
1100
1400×1030
1400×1100
1400×1250
1400×1350
1600×1350
1600×1500
1800×1500
2000×1350
1800×1700
2000×1500
2000×1750
2150×1600
1450×1195
1450×1265
1450×1415
1450×1515
1650×1515
1650×1665
1890×1685
2090×1535
1890×1885
2090×1685
2090×1935
2240×1785
1800
1800
1800
1800
2000
2000
2400
2600
2400
2600
2600
2750
1630
1700
1850
1950
1950
2100
2200
2050
2400
2200
2450
2300
3750
3750
3750
3750
4150
4150
4950
5350
4950
5350
5350
5650
1630
1700
1850
1950
1950
2100
2200
2050
2400
2200
2450
2300
2100
2100
2100
2100
2300
2300
2700
2900
2700
2900
2900
3050
3400
3500
3650
3750
3750
3900
4000
3850
4200
4000
4250
4100
4100
4100
4100
4100
4500
4500
5300
5700
5300
5700
5700
6000
3400
3500
3650
3750
3750
3900
4000
3850
4200
4000
4250
4100
4050
4100
4200
4550
5100
5450
8000
8000
8900
8900
10200
10200
2500
2500
2800
2900
3800
4300
5200
5200
6000
6000
7000
7000
6550
6850
7450
7850
9000
9650
14100
15400
16950
4800
5000
5350
5550
6250
6650
10400
11150
12000
Speed(m/min) Person Load(kg)
EntranceOpening
(mm)Inside
AN×BN
Outside
AS×BS AH BH AH BH R1 R2 R3 R4
Car Size Hoistway Size Machine Room Reaction Load(kg)Simplex Duplex
Capacity Pit ReactionLoad(kg)
AM BM AM BM
Machine Room Size
Simplex Duplex
7
8
9
10
12
13
16
18
21
21MID RISE
Planning Guide For Dimensions | Di2 (Speed : 120&150 m/min), Geared
Standard
Speed(m/min)
120
150
13
15
17
20
24
900
1000
1150
1350
1600
900
900
1000
1000
1100
1600×1350
1600×1500
1800×1500
1800×1700
2000×1750
1690×1535
1690×1685
1890×1685
1890×1885
2090×1935
2200
2200
2400
2400
2600
2150
2300
2300
2500
2550
4550
4550
4950
4950
5350
2150
2300
2300
2500
2550
6900
6900
7500
7500
8100
2150
2300
2300
2500
2550
2800
2800
3000
3000
3200
4100
4200
4200
4400
4500
5200
5200
5600
5600
6000
4100
4200
4200
4400
4500
7500
7500
8100
8100
8700
4700
4800
4800
5100
5200
11100
11650
12300
13100
13900
7550
7850
8250
8850
9350
13250
13950
16600
18050
19550
10100
10550
12650
13550
14350
PersonLoad(kg)
EntranceOpening
(mm)Inside
AN×BN
Outside
AS×BS AH BH AH BH AH BH AM BM AM BM AM BM R1 R2 R3 R4
Car Size Hoistway Size Machine Room Size Machine Room Reaction Load(kg)Simplex Duplex Triplex Simplex Duplex Triplex
Capacity Pit ReactionLoad(kg)
(Unit:mm)
Malaysia, Singapore
120
150
13
15
17
20
23
900
1020
1155
1360
1565
900
900
1000
1000
1100
1600×1350
1600×1550
1800×1500
1800×1750
2000×1750
1690×1535
1690×1735
1890×1685
1890×1935
2090×1935
2200
2200
2400
2400
2600
2150
2350
2300
2550
2550
4550
4550
4950
4950
5350
2150
2350
2300
2550
2550
6900
6900
7500
7500
8100
2150
2350
2300
2550
2550
2800
2800
3000
3000
3200
4100
4250
4200
4450
4500
5200
5200
5600
5600
6000
4100
4250
4200
4450
4500
7500
7500
8100
8100
8700
4700
4850
4800
5150
5200
11100
11650
12300
13100
13900
7550
7850
8250
8850
9350
13250
13950
16600
18050
19550
10100
10550
12650
13550
14350
PersonLoad(kg)
EntranceOpening
(mm)Inside
AN×BN
Outside
AS×BS AH BH AH BH AH BH AM BM AM BM AM BM R1 R2 R3 R4
Car Size Hoistway Size Machine Room Size Machine Room Reaction Load(kg)Simplex Duplex Triplex Simplex Duplex Triplex
Capacity Pit ReactionLoad(kg)
EN Code
Speed(m/min)
120
150
12
13
16
18
21
900
1000
1200
1350
1600
900
900
1000
1000
1100
1600×1350
1600×1500
1800×1500
1800×1700
2000×1750
1690×1535
1690×1685
1890×1685
1890×1885
2090×1935
2200
2200
2400
2400
2600
2150
2300
2300
2500
2550
4550
4550
4950
4950
5350
2150
2300
2300
2500
2550
6900
6900
7500
7500
8100
2150
2300
2300
2500
2550
2800
2800
3000
3000
3200
4100
4200
4200
4400
4500
5200
5200
5600
5600
6000
4100
4200
4200
4400
4500
7500
7500
8100
8100
8700
4700
4800
4800
5100
5200
11100
11650
12300
13100
13900
7550
7850
8250
8850
9350
13250
13950
17550
18050
19550
10100
10550
13300
13550
14350
PersonLoad(kg)
EntranceOpening
(mm)Inside
AN×BN
Outside
AS×BS AH BH AH BH AH BH AM BM AM BM AM BM R1 R2 R3 R4
Car Size Hoistway Size Machine Room Size Machine Room Reaction Load(kg)Simplex Duplex Triplex Simplex Duplex Triplex
Capacity Pit ReactionLoad(kg)
Speed(m/min)
22 SIGMA Elevator
Technical Data
Electrical Design Guide
Di1 (Speed : 60,90 & 105 m/min)
Note. Please contact us if the distance of lead - in wire exceeds 50m.
Heat Output of Machine Room
kcal / H = F×L×S (H : Hour / F : Factor = 1/40 / L : Rated Load(kg) / S : Rated Speed (m/min) / *cal = 4.2 Joule)
220V 400V
Speed(m/min) Person
Load(kg)
MotorCapa.(kW)
Simplex Duplex Simplex Duplex Simplex Duplex
MCCB Capacity of Building (A)Power SupplyCapacity(kVA)
Lead - in Wire Size(mm2) Earth Wire Size(mm2)
Heat Output (kcal / H)
Starting Power(kVA / set)
Capacity
60
90
105
6
8
9
10
11
13
15
17
20
24
8
9
10
11
13
15
17
20
24
8
9
10
11
13
15
17
20
24
450
550
600
680
750
900
1000
1150
1350
1600
550
600
680
750
900
1000
1150
1350
1600
550
600
680
750
900
1000
1150
1350
1600
5.5
5.5
7.5
7.5
11
11
11
11
11
11
9.5
9.5
9.5
9.5
13
13
13
15
15
11
11
11
11
15
15
15
18
18
50
50
50
75
75
75
75
75
100
100
75
75
75
75
75
75
100
100
125
75
75
75
75
100
100
125
125
150
100
100
100
150
150
150
150
150
125
200
100
100
100
150
150
150
200
200
250
100
100
100
150
150
150
250
250
300
60
60
60
100
100
100
100
100
100
100
60
60
60
100
100
100
100
100
125
60
60
60
100
100
100
125
125
125
4.2
5.1
5.5
6.3
6.9
8.3
9.2
10
8.9
10.5
6.6
7.1
8.1
8.9
10.7
11.9
11.3
12.8
15.2
7.6
8.3
9.4
10.4
12.5
13.8
13.2
15
17.7
8.4
10.2
11
12.6
13.8
16.6
18.4
20
17.8
21
13.2
14.2
16.2
17.8
21.4
23.8
22.6
25.6
30.4
15.2
16.6
18.8
20.8
25
27.6
26.4
30
35.4
30
30
30
50
50
50
50
50
50
50
50
50
50
50
50
50
60
50
75
50
50
50
50
50
50
60
75
75
8
8
8
14
14
22
22
22
22
22
14
14
14
14
22
22
22
38
38
14
14
14
14
22
22
38
38
60
14
14
14
22
22
38
38
38
38
60
22
22
38
38
38
38
60
60
60
38
38
38
38
60
60
60
60
100
5.5
5.5
5.5
8
8
14
14
14
14
22
8
8
14
14
14
14
22
22
22
14
14
14
14
22
22
22
22
38
5.5
5.5
5.5
5.5
5.5
5.5
5.5
5.5
5.5
8
5.5
5.5
5.5
5.5
5.5
5.5
8
14
14
5.5
5.5
5.5
5.5
8
8
14
14
22
5.5
5.5
8
8
8
8
8
14
14
14
14
14
14
14
14
14
14
3.5
3.5
5.5
5.5
5.5
5.5
5.5
5.5
5.5
5.5
5.5
5.5
5.5
5.5
5.5
5.5
5.5
675
825
900
1020
1125
1350
1500
1725
2025
2400
1238
1350
1530
1688
2025
2250
2588
3040
3600
1445
1575
1785
1970
2365
2625
3019
3544
4200
5.5
5.5
5.5
5.5
5.5
5.5
5.5
5.5
5.5
5.5
5.5
13.1
16
17.5
19.9
21.8
26.2
29.1
23
28.1
33.3
20.7
22.6
25.6
28.2
33.8
37.6
35.9
40.7
48.2
24.1
26.3
29.8
32.8
39.4
43.8
41.8
47.4
56.2
Speed(m/min) Person
Load(kg) Simplex Duplex Triplex Fourplex Simplex Duplex Triplex Fourplex
MCCB Capacity of Building(A)Power SupplyCapacity(kVA)
EarthWire
Size(㎟)
HeatOutput(kcal/H)
StartingPower
(kVA/set)
CapacityMotorCapa.(kW)
15
17
20
24
15
17
20
24
120
150
1000
1150
1350
1600
1000
1150
1350
1600
3000
3450
4050
4800
3750
4313
5063
6000
14
14
14
14
14
14
22
22
35
39
43
48
46
51
57
64
18
20
22
24
22
24
27
30
90 50105 60125 75150 85120 70130 80155 90185 110
Simplex Duplex Triplex Fourplex
Lead-in WireSize(㎟)
38 1450 1450 1460 2250 1460 1460 2280 22
100 22100 30125 38150 38125 30150 38200 38200 50
150 30200 38200 60250 60200 50250 60325 60325 80
200 38200 50250 80325 80250 60325 80400 80500 100
180 100205 115250 140295 165235 130260 145305 170365 205
240 135280 160340 195400 230315 185355 205415 240495 290
275 155320 185390 225455 265360 210405 235475 275570 330
41
46
53
62
50
57
65
77
15
17
20
23
18
21
24
28
30
34
40
46
37
42
48
57
46
51
59
69
55
63
73
85
200V 400VDi2 (Speed : 120, 150 m/min), Geared
Entrance Details
Narrow Jamb without Transom PanelDoor Machine : SAV1
Note1. “H”dimension in building structure plan depends upon the type of hall indicator selected.
2. “J”dimension depends upon governing code requirement for height(above floor) of hall buttons.
3. Unit : mm
Section B-B Section A-A
Front View of Entrance
Building Structure Plan
23MID RISE
24 SIGMA Elevator
Technical Data
S-Type Wide Jamb with Transom Panel(with accentric line)Door Machine : SAV1
Building Structure Plan
Section B-B
Front View of Entrance
Section A-A
Note1. “H”dimension in building structure plan depends upon the type of hall indicator selected.
2. “J”dimension depends upon governing code requirement for height(above floor) of hall buttons.
3. Unit : mm
Entrance Details
T-Type Wide Jamb with Transom Panel(With accentric line)Door Machine : SAV1
Note1. “H”dimension in building structure plan depends upon the type of hall indicator selected.
2. “J”dimension depends upon governing code requirement for height(above floor) of hall buttons.
3. Unit : mm
Section A-A
25MID RISE
Section B-B
Front View of Entrance
Building Structure Plan
26 SIGMA Elevator
Technical Features
Feature RemarkDescription
Anti-nuisance operation ●
In case of substantial difference between the number of calls registered on the car operatingpanel and actual load in the elevator, the elevator prevents unnecessary operation bycancelling all registered calls when it arrives at the nearest floor.
Car call cancellation ●Allows cancellation of an incorrectly registered car call. If you push a wrong floor button inthe car, you can cancel it by pressing the same button one more time.
Automatic turn off of carlight and fan
●Car illumination and fan are turned off automatically in case there is no hall call or car call tosave energy.
By pass operation (80%) ●If the actual load comes to more than 80% of the allowable maximum load, the elevatorwill not react to the calling signals from other passing floors.
Over load (110% of ratedload) holding stop
Anti hall button jamming
Door reopen control
Car door safety edge
Automatic adjustment ofdoor time
Micro Leveling
Back-up operation
Safety Drive operation
Voice synthesizer
Door photo sensor
●
●
●
●
●
●
●
●
○
○
When the load of passengers exceeds the maximum capacity, a buzzer sounds and theelevator remains stopped at that floor. When the passengers get off, the buzzer will stop.Consequently elevator doors will close and operation continues.
If landing door would not closed by a hall button’s jamming and it is caused car can’t startthen, the floor will close in force by the command from controller so that the car servicenext calls.
While the car door is closing, if a door reopen signal is occured the door will be reopenedimmediately and after specified time expired the door will again close.
This device enables the doors to return to the fully open position, should the door encountera person or obstacle while closing.
Door closing time can be adjusted in order to improve the efficiency.
An automatic two-way leveling device is provided to maintain the elevator car level with thelanding, regardless of elevator load or direction travel
In normal operation, if the serial communication between the controller and it’s terminalboard have something malfunction, the car mode is changed to a “back-Up” modeautomatically, then the car checks itself by servicing every even floors and every odd floorsuntil the car returns normal condition. By this operation, even though the car has somethingmalfunction, passergers can be offered a limited service without shoutdown.
During normal operation, a malfunction is occurred suddenly but it’s not serious, in thiscase, if the car is not in a door zone, then the car starts to run to the nearest floor in slowspeed. After stop at the nearest floor, the care remains stop with door fully open and “Outof Service” lamp. If the car condition is possible to return a normal condition itself then, thecar can service normal operation again.
This system provides passengers with audio information about car operation such asdirection of travel, landing floor, etc.
The doors will return to fully open position if the light ray unit detects an obstacle when thedoors are closing.
● Standard ○ Option
Multi-Photo ○When passengers are entering or getting out of the elevator, the multi-photo device willprevent the door from closing.
Forced floor stop ○After service on specific floor stop by car call, the car is operated normally.
Supervisory panel ○
○
This panel monitors elevator operations and conditions of emergency operations from thebuilding’s control room
Parking Operation
In order for park the elevator, if the parking key is on position the car stop at the specifiedfloor after finish servicing of all of registered calls. After the car stops at the specified floor,the car light and fan are off automatically and every buttons both on the car operatingpanel and hall button box are no more available.
Fire return operation
Fireman Operation
○
○
In case of fire every cars should be returned to the specified floor in order to evacuatepassengers safety.
In case of fire, a firemen can use the elevator which is stopped at the specified floor in orderto support firemen for fire-fighting.
Technical Data
27MID RISE
Work By Others
Hoistway
∙A properly framed and enclosed hoistway, including any ventilation as required by the governing code or authority.
∙A dry pit constructed to the elevator manufacturer's specifications to reinforce or sustain any vertical forces
on the guide rails and impacted loads from the car and counterweight buffers.
∙A metal sill angle or concrete haunch across the full width of the hoistway at each elevator landing.
∙Provision of steel bars to fix jamb around the entrance of each floor.
∙All cutting, including cutouts to accommodate hall singal fixtures, patching, painting of walls, floors, or
partitions, together with finish painting of entrance doors and frames, if required.
∙Provision of entrance or ladder for pit access
∙Supply and installation of fascia plate.
∙Installation of emergency exits and electric wiring in blind sections of hoistway where required.
∙The tolerance of perpendicular line over the whole hoistway height must not exceed ±30mm.
∙A waterproof outlet and light fixture in the elevator pit area with the light switch being located adjacent to the
access door or ladder.
∙Suitable light fixture and convenience outlet in the pit with a light switch adjacent to the access door or ladder.
The receptacles shall have protection for ground fault circuit interrupter.
The works below are not included in the elevator installation work and should be carried out by building
contractors in accordance with our drawings, relevant international or local codes and regulations.
Machine Room
∙Provision of wiring between controller and building management system.
∙A construction hoisting beam or hook, if required, with the correct location and size as determined
by the elevator contractor for each hoistway.
∙Noise insulation should be installed between machine room and adjacent residential area.
∙A suitable machine room with legal access, ventilation and concrete floor.
The temperature in the machine room should be maintained between 5℃ and 40℃.
Relative humidity should not exceed 90%(monthly) and 95%(daily) non-condensing.
Ventilation fan or air conditioner should be provided as per heat dissipation by the elevator contractor.
∙The size of entrance shall be Min.1000mm(W) x 2000mm(H).
∙Installation of lead-in wire and earth wire between building main power board and machine room incoming
distribution board. However, machine room lighting source supply shall be installed separately.
∙Provision of suitable light fixture and convenience outlets in the machine room
Miscellaneous
∙Wiring and piping between monitoring system.
∙Machine room and hoistway shall be free of dust or harmful gas.
∙All electric power for lighting, tools, welding, etc during installation.
∙All single phase receptacles installed in machine room, pit, and machinery spaces shall have ground
fault circuit interrupter protection.
∙Fire detector for fire emergency operation.
∙A secured area for storage of elevator equipment and materials during installtion.
SIGMA constantly endeavors to improve products so that information in this catalog is subject to change without notice.
2006. 8 Printed in Korea