Microprobing with electrons
-
Upload
jonathan-price -
Category
Documents
-
view
603 -
download
0
Transcript of Microprobing with electrons
![Page 1: Microprobing with electrons](https://reader033.fdocuments.us/reader033/viewer/2022050922/55a051941a28abbe578b474a/html5/thumbnails/1.jpg)
Electron MicroProbe Analysis
Characterizing Mineral ChemistryJon Price, Rensselaer Polytechnic Institute
![Page 2: Microprobing with electrons](https://reader033.fdocuments.us/reader033/viewer/2022050922/55a051941a28abbe578b474a/html5/thumbnails/2.jpg)
EMPA is a powerful tool for compositional analysis at the micrometer scale
Virtues
•Non destructive
•Highly accurate (up to 10 ppm)
•Fast
•Appropriate for chemical scale
•Somewhat inexpensive
W A R N I N G
This is complicated technology - avoid “black box” syndrome
![Page 3: Microprobing with electrons](https://reader033.fdocuments.us/reader033/viewer/2022050922/55a051941a28abbe578b474a/html5/thumbnails/3.jpg)
Most minerals are sized between 0.1 - 100’s of mm.The rather ordinary rock slab on the left is composed of small (1-5mm) grains of quartz and feldspar.
The feldspar below is large (15 mm) but is concentrically zoned.
![Page 4: Microprobing with electrons](https://reader033.fdocuments.us/reader033/viewer/2022050922/55a051941a28abbe578b474a/html5/thumbnails/4.jpg)
Feldspars are solid-solutions and exhibit a range of compositions.
How might we determine the composition of the minerals in our rocks?
What is unique about each element?
MM
TT
TT
![Page 5: Microprobing with electrons](https://reader033.fdocuments.us/reader033/viewer/2022050922/55a051941a28abbe578b474a/html5/thumbnails/5.jpg)
Ephoton = EH - EL = h f = h c / λ
1. To obtain composition, we need a measurable characteristic for each element.
Electron structure is element specific. In other words, Ephoton is the result of a specific jump in a specific element.
Fluorescence: electromagnetic radiation results from moving electrons closer to the nucleus
![Page 6: Microprobing with electrons](https://reader033.fdocuments.us/reader033/viewer/2022050922/55a051941a28abbe578b474a/html5/thumbnails/6.jpg)
Examples of transition levels in Barium
K 37.44 keV
LI 5.99 keV
LII 5.63 keV
LIII 5.25 keV
So LII to K (K α1) is…
31.81 keV
Heavier atoms have many energy levels
![Page 7: Microprobing with electrons](https://reader033.fdocuments.us/reader033/viewer/2022050922/55a051941a28abbe578b474a/html5/thumbnails/7.jpg)
So LIIto K is 31.81 keV or 31,810 eV
The wavelength of the photon produced by this jump is
λ = h c / E
h = 6.626 × 10-34 m2 kg/s
c = 3 × 108 m/s
E = 31,810 eV × 1.602 × 10-19 J/ eV = 5.096 × 10-15 J
So λ = 3.900 × 10-11 m
![Page 8: Microprobing with electrons](https://reader033.fdocuments.us/reader033/viewer/2022050922/55a051941a28abbe578b474a/html5/thumbnails/8.jpg)
2. To get analysis at micron scale, we need high energies (keV) focused on small area
Electrons are charged particles that can be focused and redirected using a magnets
Lower energy example: the CRT
Raymond Castaing formulated the technique for microanalysis and built the first working unit by 1951.
![Page 9: Microprobing with electrons](https://reader033.fdocuments.us/reader033/viewer/2022050922/55a051941a28abbe578b474a/html5/thumbnails/9.jpg)
3. Fluoresced x-rays need to be collected and counted.
Recall that crystalline structure diffracts x-rays(XRD)
Bragg equation: λ = 2d sin θ
Crystal with unknown d spacing
X-ray source with known λ
![Page 10: Microprobing with electrons](https://reader033.fdocuments.us/reader033/viewer/2022050922/55a051941a28abbe578b474a/html5/thumbnails/10.jpg)
Castaing’s machine: focused electron beam that produces x-rays in an unknown, that may be counted at known diffraction angles.
Wavelength dispersive spectrometry (WDS)
Bragg equation: λ = 2d sin θ
![Page 11: Microprobing with electrons](https://reader033.fdocuments.us/reader033/viewer/2022050922/55a051941a28abbe578b474a/html5/thumbnails/11.jpg)
The intensity of x-rays is much smaller relative to those generated from a tube (as in XRD)
The EMP wavelength spectrometer uses crystals with curved lattices and ground curvature to reduce lost x-rays
The Rowland Circle
Crystal
Detector
InboundX-rays
![Page 12: Microprobing with electrons](https://reader033.fdocuments.us/reader033/viewer/2022050922/55a051941a28abbe578b474a/html5/thumbnails/12.jpg)
Example of a modern EM probe
Locate the following:Cathode and
anodeBeamMagnetsSampleCrystalDetector
![Page 13: Microprobing with electrons](https://reader033.fdocuments.us/reader033/viewer/2022050922/55a051941a28abbe578b474a/html5/thumbnails/13.jpg)
The Cameca SX100• Five spectrometers• Each with 2-4 crystals
The new RPI facility
Cameca SX 100 EMPRontec EDS detectionGatan mono CL
![Page 14: Microprobing with electrons](https://reader033.fdocuments.us/reader033/viewer/2022050922/55a051941a28abbe578b474a/html5/thumbnails/14.jpg)
Electron forces jumpChar. photon producedGlancing background phn
Produced photon adsorbed - may produce Auger e-
Electron bounces off atom (high E): backscattered
Electron knocks out another e- (low E): secondary
More on electron-sample interactions
![Page 15: Microprobing with electrons](https://reader033.fdocuments.us/reader033/viewer/2022050922/55a051941a28abbe578b474a/html5/thumbnails/15.jpg)
EMPA does not analyze surfaces (thin film), but penetrates a small volume of the sample.
The collectable products of electron collision origin originate from specific volumes under the surface.
![Page 16: Microprobing with electrons](https://reader033.fdocuments.us/reader033/viewer/2022050922/55a051941a28abbe578b474a/html5/thumbnails/16.jpg)
Secondary electrons emitted from the first 50 nmImages surface topography
Backscattered electron intensity are a function of atomic densityImages relative composition
Other electron-sample interactions are useful
![Page 17: Microprobing with electrons](https://reader033.fdocuments.us/reader033/viewer/2022050922/55a051941a28abbe578b474a/html5/thumbnails/17.jpg)
Ti
Characteristic x-ray emission
![Page 18: Microprobing with electrons](https://reader033.fdocuments.us/reader033/viewer/2022050922/55a051941a28abbe578b474a/html5/thumbnails/18.jpg)
The x-ray volume changes as a function of a number variables.
A sample with higher average atomic density will have a shallower but wider volume than one with a lower density.
A beam with higher energy (keV) will produce a larger volume than one with a lower E0.
Nonunique nature of emission volume
![Page 19: Microprobing with electrons](https://reader033.fdocuments.us/reader033/viewer/2022050922/55a051941a28abbe578b474a/html5/thumbnails/19.jpg)
From the excitation volume behavior, it is clear atomic density (Z) makes a difference in the emitted intensities.
Some of the x-rays are absorbed into atoms within and adjacent to the excitation volume.
Some of the x-rays promote electron jumps in atoms within and adjacent to the excitation volume.
Z
A
F
Raw data are corrected for ZAF influences. The total correction produces a rather long equation that may be satisfied only through iteration.
The microprobe advanced as a tool because of the microprocessor
Sample effects
![Page 20: Microprobing with electrons](https://reader033.fdocuments.us/reader033/viewer/2022050922/55a051941a28abbe578b474a/html5/thumbnails/20.jpg)
The number of x-rays counted at the appropriate diffraction angle is proportional to the concentration of the fluorescing element. But the excitation volume is not unique.
Quantification requires comparison to a well-characterized standard.
Standard analyzed by other means
Your sample with unknown composition
![Page 21: Microprobing with electrons](https://reader033.fdocuments.us/reader033/viewer/2022050922/55a051941a28abbe578b474a/html5/thumbnails/21.jpg)
Castaing’s micro WDS machine was a breakthrough. By 1960, advances in semiconduction permitted the construction of a new detector that could collect all of the emitted x-ray energies (pulses and background) within a few seconds.
Energy Dispersive Spectrometry (EDS)
•Measures charges in semiconductor [Si(Li)]
•Makes histogram of measured charges
•Extremely fast
•Very inexpensive
•Lower accuracy relative to WDS
![Page 22: Microprobing with electrons](https://reader033.fdocuments.us/reader033/viewer/2022050922/55a051941a28abbe578b474a/html5/thumbnails/22.jpg)
EDS spectrum for a 15kV beam on a gemmy crystal from the Adirondacks (M. Lupulescu, NYSM).
Al Kα & β
Si Kα & β
K Kα
K Kβ
![Page 23: Microprobing with electrons](https://reader033.fdocuments.us/reader033/viewer/2022050922/55a051941a28abbe578b474a/html5/thumbnails/23.jpg)
![Page 24: Microprobing with electrons](https://reader033.fdocuments.us/reader033/viewer/2022050922/55a051941a28abbe578b474a/html5/thumbnails/24.jpg)
EM P A t r a v e r s e s o f s p in e l u s in g WD S
Formula for the spinel
Nom: Mg Al2O4
Act: Mg1-3x Al2+2x O4
![Page 25: Microprobing with electrons](https://reader033.fdocuments.us/reader033/viewer/2022050922/55a051941a28abbe578b474a/html5/thumbnails/25.jpg)
![Page 26: Microprobing with electrons](https://reader033.fdocuments.us/reader033/viewer/2022050922/55a051941a28abbe578b474a/html5/thumbnails/26.jpg)
EMPA is a powerful tool for compositional analysis at the micrometer scale
High voltage electron beam can be focused on one micrometer area
Composition is determined by characteristic x-rays from excited atoms
WDS
•Characteristic x-rays are focused through diffraction
•Permits better resolution
EDS
•All x-rays are counted simultaneously
•Permits faster analysis / identification
![Page 27: Microprobing with electrons](https://reader033.fdocuments.us/reader033/viewer/2022050922/55a051941a28abbe578b474a/html5/thumbnails/27.jpg)
Limitations
•Good standards are essential
•Quantification is dependant on accurate correction for ZAF effects
•User needs to be aware of excitation volume
Results
•Accurate assessment of mineral stoichiometry
•WDS provides trace element compositions
•May assess inhomogeneity at small scales