ELLIPTICAL MOBILE SOLUTIONS, LLC Save Money, Energy Time and Space
Today’s Data Centre Challenges
Digital Explosion
Worldwide:
Aging Infrastructure:
Rising Energy Use:
Costs Are Out of Control:
How much electricity would you waste if you cooled your house just to keep the milk cool?
Patented “Closed Loop Cooling” from EMS
brings up to 50%+ Electricity Savings
=
Industry Change – Containerized Data Centres = Less Capital $ More Efficient
Average Data Centre PUE 2.5 Containerized Data Centres PUE 1.1-1.5 $/Kilowatt of IT: 25,000-15,000 $/Kilowatt of IT: 8,000-4,000 Brick & Mortar Container MMDC
Resilient Data Centre Infrastructure Platform
EMS Standardized Infrastructure Provides Multi Tier Cross Purpose Disaster
Infrastructure Solutions
MMDC Cooling Efficiency Characteristics
• “Best Practice” airflow “forces” most efficient method
• Pre Engineered – No airflow analysis required
• Hot Aisle Containment – No remixing of hot air into servers
• Cold Aisle Containment – Delivers 100% of cold air to equipment intake
• Zero Bypass Airflow – Cold air is forced through equipment
Equipment
Cold Air “Raised Floor”
Equipment
Equipment
Equipment
Equipment
Data Centre
Reduce “Embodied Carbon” by 60%
• Reduced complexity of data centre facilities construction
• Results in less embodied carbon in building shell
• Enables renewable material choices
• Reduced “embodied pollution” of construction process
• “ Cradle to Grave” MMDC is all steel and portable and can be reused in
other locations or recycled at end of life
0%20%40%60%80%
100%
Brick an
d M
ortar
Co
ntain
erized
RecyclableAsset
BuildingShell
MMDC: Scalable, Mobile Footprint = Less Environmental Impact
Permanent 2000 KW Data Centre
Facility
500 KW Container
500 KW Container
500 KW Container
2MW Brick & Mortar
500 KW Container
Semi Permanent 2MW Containerized
40
40
40
40
40
40
40
40
40
40
40
40
40
40
40
40
40
40
40
40
40
40
40
40
40
40
40
40
40
40
40
40
40
40
40
40
40
40
40
40
40
40
40
40
40
40
40
40
40
40
Portable 2MW MMDC (Containerized)
= Data Centre Size
Practical Applications
New Data Center &
Data Center
Consolidation
• HPC
• Cloud Computing
• High Density Zone
• Expansions
R.A.S.E.R. HD
R.A.S.E.R. DX
C3-S.P.E.A.R.
• Disaster
Recovery
• Remote Office
• IT on the Move
• Telco
• Industrial
R.A.S.E.R. DX Features
C
o
l
d
A
i
s
l
e
H
o
t
A
i
s
l
e
Equipment
Equipment
Equipment
Equipment
Cold Air
• Built-in cooling • 12KW IT load • 42,000 BTU • Vapor cycle “DX”
• Shock and vibration isolation
• Hardened enclosure
• Scalable and modular
• Self-contained
• Mission Critical Venting (Optional)
Compressor Condenser/ Evaporator
Portable Cloud Computing (Example Solution)
Three Industry Leaders
One Architecture…
Expand Data Centre Capacity with Energy Efficient High Density Zone
“EXAMPLE SOLUTION”
“Future Growth”
Blade Servers
STORAGE
R.A.S.E.R. HD Features
• Redundant (N+1 AND 2N), hot swappable
heat exchanger units
• 42U of rack space available in the main
cabinet
• 2 “sidecars” contain heat exchanger (HX)
units
• Sealed environment
• Close coupled cooling allows high
temperature water
• A / B water loops and multiple hot-
swappable fans
• Multiple configurations starting at 20 KW
• 42U of rack space available in the main
cabinet
• 2 “sidecars” contain heat exchanger (HX)
units
• Sealed environment
• Close coupled cooling allows high
temperature water
• A / B water loops and multiple hot-
swappable fans
• NEMA 4 environmental package
• Redundant (N+1 AND 2N), hot swappable
heat exchanger units
• Multiple configurations starting at 20 KW
and growing to 80 KW in a single enclosure
C³SPEAR Features
• 24U of blade ready space
• 2 Self contained close coupled cooling units support N+1 or 2N closed loop cooling.
• 2.5KW, redundant 2N
• 6KW, redundant N+1
• Power assisted mobility
• NEMA 12 or Option NEMA 4 environmental package
• A/B power input for IT
• A/B power input for cooling
• Custom interconnections available
• Waterproof
• Shielded
• Shock and vibration isolation
Available Options On All
Active Fire Suppression System • VESDA • HSSD • NOVEC 1230 • F-GAS
Cyber Lock Security System • Stand alone power • 4,000 user event audit trail • Card reader security interface • Enterprise class software • Remote programability
Shock and Vibration Isolation • Protects Equipment while being moved
or relocated • Disaster Tolerant
Data Centre Challenges Today
Technology Refresh Data Centre Consolidation Energy Saving Initiatives Expensive Build Cost Floor Space Constraints Inflexible Infrastructure
Limited Cooling/ Electrical Capacity Runaway Electrical Bill Cost Expensive Retrofit for High Density Zone Constant Demand for Expansion Under Utilized Compute Resources Virtualization Infrastructure Challenges
Problems Solved
•Up To 50% $ Savings on Electricity •Patented zero bypass cooling system •50-80% More efficient = Green
•Up To 75% Floor Area Savings •25 ft² for EMS enclosures vs. 100 ft² traditional raised floor
•Fireproof and Water Proof •Air Tight Closed Loop System
•Eliminates Shock and Vibration Damage •Patented Equipment Suspension
•Scalable from 1 Micro Data Centre to 100’s; “Pay as You Need” •Purchase cooling, security, fireproofing, raised floor, hot and cold isle
Micro Modular Data Centres ELLIPTICAL MOBILE SOLUTIONS, LLC
• Save Money – Eliminate costly infrastructure with a self-contained, high-density, cost-effective and energy efficient
data centre.
– Reduce the costs to plan, build and implement your data centre
– Reduce overall operating expenses
• Save Energy – Patented closed loop cooling dramatically cuts cooling and electrical costs
– Significantly reduce data centre’s harmful carbon footprint
• Save Time – Micro-Modular Data Centre’s can be built, fully populated and delivered in weeks vs. months or years
– Have a fully functional data centre when, where and for however long you need it
• Save Space – Reduce your data centre footprint by up to 70 percent
– EMS products can be located in a warehouse, garage, office or closet