Micro fiber cable blowing machine ElectroFOK

4
ELECTROFOK MACHINE ELEKTROFOK (MICRO FIBER OPTIC CABLE BLOWING MACHINE with ELECTRIC)

Transcript of Micro fiber cable blowing machine ElectroFOK

Page 1: Micro fiber cable blowing machine ElectroFOK

ELECTROFOK MACHINE

ELEKTROFOK (MICRO FIBER OPTIC CABLE BLOWING MACHINE with ELECTRIC)

Page 2: Micro fiber cable blowing machine ElectroFOK

GENERAL DESCRIPTIONELEKTROFOK is designed and produced with feedbacks from users who has specialty on cable blowing technologies.

Elektrofok is using to blow cables from 1mm to 5 mm. You need to give us duct diameters in your project before ordering machine.

Machine consists on four parts as you can see in figure 1.

*Cable blowing group is blowing cable in duct with controlling by electric panel.

*You can control cable blowing speed and direction .

*You can see the distance of cable you blowed from electric panel .

*The most important thing of machine is sensor design which prevents breaking of cable .

Machine stops before breaking of cable.

*Air regulater system is setting air pressure in duct and also you can open ,close air.

*You can put machine on desired place and height with high quality tripod table.

Elektrofok = Micro fiber optic cable blowing machine with electric.

Control = Technician.

Needed electricity = City electric.

Needed air = 15 bar -1 metercup/minute (NOTE=It can be changed to the different factors)

Cable blowing speed = 0 to 50 meter/minute

Dimensions of machine = 30 cm * 40cm * 15cm

Dimensions of box = 71 cm * 45cm * 42cm

Weight of machine with box = 28 kg

1) Cable Blowing Group

3) Air

Regulater

Group

2) Electric

Panel Group

4)Tripod

Table

1)USING CABLE BLOWING GROUP

1-A)MONTAGING DUCT ,NUTRINGS AND O-RINGS

Figure-1

Figure-2-a

Duct Montaging = Push the duct to the barrier (part 1 on figure 2) then turn part 2 to

fix duct between part 3 and 4 as in the figure 2-a.

Montaging Nutring = The part 6 in figure 2-b is nutring.When you montage nutring,

air canals of nutring must be on the direction of duct. Nutrings must be cutted from to take

cable out from the nutring.When you montage nutring , cutted place must be on the

underside to prevent air leaks .

Montaging O-rings = Part 5 in figure 2-b is o-ring. O-rings is montaging between duct

and nutring as in the figure 2-b .If you do not montage nutrings like that air leaks

happens.You need to change nutrings after someuse to prevent air leaks.

1

2 534 6

Figure-2-b

Page 3: Micro fiber cable blowing machine ElectroFOK

1-B)MONTAGING FIBER OPTIC CABLE and

ADJUSTING PRESSURE ON CABLE BETWEEN

ROLLS

Figure-3 Figure-4

Montage fiber optic cable on machine as in the figure 3 and

then close machine ‘s upper part by turning part 5.Fix clamps as in

figure 4 to prevent air leaks .Wheels presses on cable ,pressure on

cable can be easily setted by turning part 6.

1-C) CHANGING THE RUBBERIZED WHEELS

Figure-5 Figure-6

6

8

Fiber optic cable is driven by rubber wheels.Rubber wheels can damage after some

use. These wheels can easily remove and change with new one as shown in Figure-5

and Figure-6. First, number 7 bolts must be took out so upper and bottom covers

will be removed. Then, number 8 bolts on the wheels must be took out. Lastly, both

wheels should remove slowly and change with spare ones.

2) INSTRUCTIONS FOR USING CONTROL PANEL

8 9 10 11

12Figure-7

-Fiber optic cable drive forward and back with switch 8. This switch moves the cable

-Speed of cable can adjust with the help of switch 9.

-When you start machine , speedof the cable must be fewer then % 50. After starting you

can increase speed.

-You can open and close the sensor from switch 11.

- Switch 11 activates the sensor to not to break cable.Gives the alarm lamb on number 10

before the cable breaks.

-See the cable blowing meter on screen 12.

5

7

Page 4: Micro fiber cable blowing machine ElectroFOK

3) INSTRUCTIONS FOR USING AIR REGULATOR UNIT

Figure-8

13

14

15

16

Air connection to the machine made on the number 13 quick connection part. Number 14 valve opens and

closes air intake. Air pressure inside the HDPE duct can adjust with the number 15 regulator. Number 16

gauge shows duct air pressure.

Minimum HDPE pipe pressure must be 10-12 bar.

4 ) USINGTRIPOD

Figure-9 Figure-10

Machine is fixing or releasing on tripod by the part 17 on figure

10.Machine can easily prepare for blowing by the tripod.Lenght of the

tripod are adjustable and portable with special bag as in the figure 11.

17

Figure-11