MHC-3000 Handheld ultrasonic flow meter data sheet

4
Product Data Sheet 1 / 4 The flow meter is a handheld type with clamp-on transducer which offers a variety of optional features. It is designed to measure the fluid velocity of liquid within closed conduit or pipe. The meter is compact and robust which comprises additional functions that can turn it into more than just a flow meter. The meter utilizes two non-contacting and clamp-on type transducers that function as both ultrasonic transmitters and receivers. The transducers are clamped on the outside of a closed pipe at a specific distance from each other. The flow meter operates by alternately transmitting and receiving a frequency modulated burst of sound energy between the two transducers and measuring the time interval that it takes for sound to travel between the two transducers. The difference in the time interval measured is directly related to the velocity of the liquid in the pipe. The meter offers a heat quantity measurement function that turns the instrument into a portable energy meter. When equipped with this feature, the flow meter Handheld Type Ultrasonic Flow Meter MHC-3000H Application --pump testing and inspection --inline flow meter performance verification --leakage and blockage detection --flow surveys --cooling and heating fluid measurements --deluge and extinguisher system testing --demineralised water measurement --clean room applications Highlights --heat measurement function optional --various units to display --great pipe range from 15 to 6000mm (1/2"~236") --temperature range from -40 to 160(-40°F~320°F) --accuracy to ±1% --light weight, no more than 600g (1.32lbs) --easy installation and operation --bi-directional flow measurement incorporates measured flow and temperature values delivered by two PT100 sensors into heat flow and heat quantity. This is valuable information to assess the efficiency of heat exchangers and HVAC systems. The meter can be ordered with an internal data logger, which is available to store up to 100,000 measurements with each measurement which can be selected by the user before each measurement. The data can be transferred via RS485. The meter can be successfully applied on a wide range of metering applications. Pipe size ranges from 15 to 6000mm (1/2" to 236") and transducers working temperature can be up to 160°C (320°F). A variety of liquid application can be accommodated: ultrapure liquids, potable water, chemicals, reclaimed water, cooling water, river water, plant effluent, alcohol, etc. Because the transducers are non-contacting and have no moving parts, the flow meter is not affected by system pressure, fouling or wear. Please consult the factory of assistance.

Transcript of MHC-3000 Handheld ultrasonic flow meter data sheet

Page 1: MHC-3000 Handheld ultrasonic flow meter data sheet

Product Data Sheet

1 / 4

The flow meter is a handheld type with clamp-on

transducer which offers a variety of optional features. It is

designed to measure the fluid velocity of liquid within

closed conduit or pipe. The meter is compact and robust

which comprises additional functions that can turn it into

more than just a flow meter.

The meter utilizes two non-contacting and clamp-on type

transducers that function as both ultrasonic transmitters

and receivers. The transducers are clamped on the outside

of a closed pipe at a specific distance from each other.

The flow meter operates by alternately transmitting and

receiving a frequency modulated burst of sound energy

between the two transducers and measuring the time

interval that it takes for sound to travel between the two

transducers. The difference in the time interval measured

is directly related to the velocity of the liquid in the pipe.

The meter offers a heat quantity measurement function

that turns the instrument into a portable energy meter.

When equipped with this feature, the flow meter

Handheld Type Ultrasonic Flow Meter

MHC-3000H

Application

--pump testing and inspection

--inline flow meter performance verification

--leakage and blockage detection

--flow surveys

--cooling and heating fluid measurements

--deluge and extinguisher system testing

--demineralised water measurement

--clean room applications

Highlights

--heat measurement function optional

--various units to display

--great pipe range from 15 to 6000mm (1/2"~236")

--temperature range from -40 to 160℃ (-40°F~320°F)

--accuracy to ±1%

--light weight, no more than 600g (1.32lbs)

--easy installation and operation

--bi-directional flow measurement

incorporates measured flow and temperature values

delivered by two PT100 sensors into heat flow and heat

quantity. This is valuable information to assess the

efficiency of heat exchangers and HVAC systems.

The meter can be ordered with an internal data logger,

which is available to store up to 100,000 measurements

with each measurement which can be selected by the user

before each measurement. The data can be transferred via

RS485.

The meter can be successfully applied on a wide range of

metering applications. Pipe size ranges from 15 to

6000mm (1/2" to 236") and transducers working

temperature can be up to 160°C (320°F). A variety of

liquid application can be accommodated: ultrapure liquids,

potable water, chemicals, reclaimed water, cooling water,

river water, plant effluent, alcohol, etc. Because the

transducers are non-contacting and have no moving parts,

the flow meter is not affected by system pressure, fouling

or wear. Please consult the factory of assistance.

Page 2: MHC-3000 Handheld ultrasonic flow meter data sheet

Product Data Sheet

2 / 4

MHC-3000H Specifications

Transmitter

Dimension 220*120*92mm (8.7"*4.7"*3.6")

Power requirements Built-in 24V Ni-MH battery (1900mAh) provides 15 hrs of continuous operation,

charging: 220V AC 56/60 Hz (adapter supported)

Velocity range 0.03-7m/s (0.01~23ft/s)

Inputs/Outputs RS485, Heat Flow

Display 2 line characters display instantaneous and accumulative flow, velocity and signal

status

Units Liters, m³, US gallon, UK gallon, s, m, h, d, l/s, m³/h, etc.

Ambient conditions -20 °C to +75 °C, 0 to 85% relative humidity (-4°F~167°C)

Accuracy ±1-3%FS

Repeatability ±0.2%

SD card Supported, at least 2GB

Page 3: MHC-3000 Handheld ultrasonic flow meter data sheet

Product Data Sheet

3 / 4

Optional Transducers

Technical

parameters N-S1 N-M1 N-L1 N-S1H N-M1H N-L1H N-HS N-HM

Applicable pipe

(mm)

15~100

(0.5"~4")

50~700

(2"~28")

300~6000

(12"~236")

15~100

(0.5"~4")

50~700

(2"~28")

300~6000

(12"~236")

15~100

(0.5"~4")

50~700

(2"~28")

Material Aluminum alloy PES (Polyether Sulfone)

Working

frequency 1 MHZ

Installation

method V (N、W) V、Z Z V (N、W) V、Z Z V (N、W) V、Z

Calibration Pairing & Calibrating for the complete machine

Magnetism Yes N/A Yes

Applicable

temperature -40~90 °C (-40°F~194°F) -40~160 °C (-40°F~320°F)

Protection IP68

Media type Water, seawater, sewage, alcohol, various oils and other single, uniform and stable liquid that can

transmit ultrasonic wave

Medium

turbidity <20000ppm with low bubble content

Applicable pipes Uniform and compact pipes made of carbon steel, stainless steel, cast iron, copper, PVC, aluminum,

glass fiber reinforced plastics, and lining is permitted.

Pipe lining

material Epoxy asphalt, rubber, mortar, polypropylene, polystyrene, bakelite, polytetrafluoroethylene etc.

Signal cable Standard configuration: 5mX2

Page 4: MHC-3000 Handheld ultrasonic flow meter data sheet

Product Data Sheet

4 / 4

Optional Heat Measurement Function

The ultrasonic flow meter with optional heat flow module installed is designed to measure the rate and quantity of heat

delivered to a given building, area or heat exchanger. The meter measures the volumetric flow rate of the heat exchanger

liquid (water, water/glycol mixture, brine, etc.), the high temperature at the inlet pipe and the low temperature at the

outlet pipe. Heat delivery is calculated by the following equation.

Rate of heat delivery = Q*(Tin – Tout)*c

Where

Q = volumetric flow rate

Tin = high temperature at the inlet

Tout = low temperature at the outlet

C = specific heat of the liquid

Honma reserves the right to alter specifications without notice.

Dalian Honma Instrument Technology Co., Ltd

Headquarter:

No.111, Beihai Industrial Park, Ganjingzi District, Dalian, Liaoning, 116085, China

Tel: 0086-411-8711 2351

Fax: 0086-411-8420 4069

Website: www.dlhmyb.com

Shanghai Sales Office:

825# Ting'an Rd, Pudong Disctrict, Shanghai, 200137, China