METHVEN AIO AURAJET TWIN SHOWER · Clip into theelbow bracket and overhead shower. • • • •...

4
METHVEN AIO AURAJET TWIN SHOWER CLEANING RECOMMENDATIONS We recommend the use of soapy water or approved cleaners. This product should not be cleaned with abrasive materials. Damage caused by improper treatment is not covered by the product warranty – refer to warranty conditions on the last page. To see the complete AIO range go to www.reece.com.au/bathrooms SPECIFICATIONS Recommended Use Domestic, hotel and commercial Colour Chrome, and Chrome with white face Pressure Rating Suitable for high pressure applications and has been WELS certied to the following: Minimum operating pressure 100kPa Maximum operating pressure 500kPa Temperature Rating Maximum continuous working temperature 70°C (recommended 38°C - 42°C) Minimum 5°C Suitable Hot Water Units Storage Tank: Yes Continuous Flow: Yes Gravity Feed: Not recommended Spray Patterns Aurajet Spray Disclaimer: Products in this specication manual must by regulation be installed by licensed and registered trade people. The manufacturer/distributor reserves the right to vary specications or delete models from their range without prior notication. Dimensions are nominal measurements only. Dimensions and set-outs listed are correct at time of publication however the manufacturer/distributor takes no responsibility for printing errors. Tech Page Version 1 1/2" BSP Female Adjustable 250 220 410 239 Typical 780 - 790 1 1 4 4 AOSSCPWHAU 2299918 AOSSCPAU 2299917 page 1 of 4 Diverter Position Bottom of rail Water Inlet Top of rail TM WMKT21090 AS/NZS 3662 The more stars the more water efficient WATER RATING www.waterrating.gov.au In accordance with AS/NZS 6400 Licence No. 0095 Methven Australia Pty Ltd 9.0 litres per minute

Transcript of METHVEN AIO AURAJET TWIN SHOWER · Clip into theelbow bracket and overhead shower. • • • •...

Page 1: METHVEN AIO AURAJET TWIN SHOWER · Clip into theelbow bracket and overhead shower. • • • • 1800mm (Recommended) 785mm FLOOR. Step 1 Install a ½” male nipple at the recommended

METHVENAIO AURAJET TWIN SHOWER

CLEANING RECOMMENDATIONSWe recommend the use of soapy water or approved cleaners. This product should not be cleaned with abrasive materials. Damage caused by improper treatment is not covered by the product warranty – refer to warranty conditions on the last page.

To see the complete AIO range go to www.reece.com.au/bathrooms

SPECIFICATIONSRecommended Use Domestic, hotel and commercial

Colour Chrome, and

Chrome with white face

Pressure Rating Suitable for high pressure applications and has been WELS certified to the following:

Minimum operating pressure 100kPa

Maximum operating pressure 500kPa

Temperature Rating Maximum continuous working temperature 70°C (recommended 38°C - 42°C)

Minimum 5°C

Suitable Hot Water Units

Storage Tank: Yes Continuous Flow: Yes

Gravity Feed: Not recommended

Spray Patterns Aurajet Spray

Disclaimer: Products in this specification manual must by regulation be installed by licensed and registered trade people. The manufacturer/distributor reserves the right to vary specifications or delete models from their range without prior notification. Dimensions are nominal measurements only. Dimensions and set-outs listed are correct at time of publication however the manufacturer/distributor takes no responsibility for printing errors.

Tech Page Version 1

1/2"

BSP

Fem

ale

Adj

usta

ble

250220

410

239Typical

780

- 790

1144

AOSSCPWHAU 2299918

AOSSCPAU 2299917

page 1 of 4

Diverter Position Bottom of rail

Water Inlet Top of rail

TM

WMKT21090AS/NZS 3662

The more stars the more water efficient

WATER RATINGwww.waterrating.gov.au

In accordance with AS/NZS 6400

Licence No. 0095Methven Australia Pty Ltd

9.0 litres per minute

Page 2: METHVEN AIO AURAJET TWIN SHOWER · Clip into theelbow bracket and overhead shower. • • • • 1800mm (Recommended) 785mm FLOOR. Step 1 Install a ½” male nipple at the recommended

METHVENAIO AURAJET TWIN SHOWER

INSTALLATION INSTRUCTIONS

Plumbers, please ensure a copy of the installation instructions is left with the end user for future reference

Step 1

• Install a ½” male nipple at the recommended height of 1800mmfrom the ground.

• Wall lining hole should be cut or finished as per the dimensionshown in the diagram on the right.

• Cut off the threaded nipple 20±2mm from the wall lining and apply thread seal tape to ensure a good seal.

• Screw the inlet connector onto the nipple ensuring that the o-ringis sufficiently compressed to create a watertight seal.

• Screw the bottom rail connector to a wall stud vertically in linewith the inlet connector and at the correct distance.

Step 2

• Firmly push the shower rail onto the top inlet connector and bottom rail connector.

• Secure in place by tighteningthe grub screws firmly using the hex key provided.

Step 4

• Fit the elbow cover into the back of the elbow bracket.

• Clip into the elbow bracket and overhead shower.

Step 5

• To adjust slider position, rotate the slider handle tounlock and lock the slider as shown.

Fit overhead shower into elbow bracket and push firmly until the clips engage.

Inlet Connector

Handset

Flat Washer

Swivelling Cone Hose End

Filter Washer

• Methven recommends this product is installed by a licensed plumber in compliance with all relevant regional regulations.

20±2mm

26mm

max

Step 2

Firmly push the shower rail onto thetop inlet connector and bottomrail connector.

Step 3

Step 4

Fit the elbow cover into the back of the elbowbracket.

Clip into the elbow bracket and overheadshower.

1800

mm

(Recomm

ended)

785mm

FLOOR

Step 1

Install a ½” male nipple at the recommended height.

Overhead

Rail

Hose

Inlet

Bottom RailConnector

Elbow Cover

Handset

Step 6

Make sure a washer is in both ends of theshower hose.

Screw one end of the hose to the bottom of the shower rail, attach handset and place firmly in holder.

It is the responsibility of the installer to ensure a waterproof seal is achieved between the product and mounting surface. If in doubt about the quality of the seal, remove the product and reinstall using silicone to ensure a seal is achieved.

All pipe work must be thoroughly flushed prior to the installation of the hose.

After installation all connections must be checked for leaks.

All outlets used primarily for personal hygiene shall deliver water at a safe temperature as per regional regulations.

IMPORTANT: Please read all of the instructions and turn off water supply before installation.

General:

2

1

Secure in place by tightening the grubscrews firmly using the hex key provided.

Shower

Shower

Connector

Bottom railConnector

Screw the bottom rail connector to awall stud vertically in line with theinlet connector and at the correct distance.

• Wall lining hole should be cut or finished as per the dimension shown in the diagram on the right.

Cut off the threaded nipple 20±2mm from the wall lining and apply thread seal tape to ensure a good seal.

Screw the inlet connector onto the nipple ensuring that the o-ring is sufficiently compressed to createa watertight seal.

Step 5

To adjust slider position, rotate the slider handle to unlock and lock the slider as shown.

Unlock

Lock

Fit overhead shower into elbow bracket and push firmly until the clips engage.

Inlet Connector

Handset

Flat Washer

Swivelling Cone Hose End

Filter Washer

• Methven recommends this product is installed by a licensed plumber in compliance with all relevant regional regulations.

20±2mm

26mm

max

Step 2

Firmly push the shower rail onto thetop inlet connector and bottomrail connector.

Step 3

Step 4

Fit the elbow cover into the back of the elbowbracket.

Clip into the elbow bracket and overheadshower.

1800

mm

(Recomm

ended)

785mm

FLOOR

Step 1

Install a ½” male nipple at the recommended height.

Overhead

Rail

Hose

Inlet

Bottom RailConnector

Elbow Cover

Handset

Step 6

Make sure a washer is in both ends of theshower hose.

Screw one end of the hose to the bottom of the shower rail, attach handset and place firmly in holder.

It is the responsibility of the installer to ensure a waterproof seal is achieved between the product and mounting surface. If in doubt about the quality of the seal, remove the product and reinstall using silicone to ensure a seal is achieved.

All pipe work must be thoroughly flushed prior to the installation of the hose.

After installation all connections must be checked for leaks.

All outlets used primarily for personal hygiene shall deliver water at a safe temperature as per regional regulations.

IMPORTANT: Please read all of the instructions and turn off water supply before installation.

General:

2

1

Secure in place by tightening the grubscrews firmly using the hex key provided.

Shower

Shower

Connector

Bottom railConnector

Screw the bottom rail connector to awall stud vertically in line with theinlet connector and at the correct distance.

• Wall lining hole should be cut or finished as per the dimension shown in the diagram on the right.

Cut off the threaded nipple 20±2mm from the wall lining and apply thread seal tape to ensure a good seal.

Screw the inlet connector onto the nipple ensuring that the o-ring is sufficiently compressed to createa watertight seal.

Step 5

To adjust slider position, rotate the slider handle to unlock and lock the slider as shown.

Unlock

Lock

Fit overhead shower into elbow bracket and push firmly until the clips engage.

Inlet Connector

Handset

Flat Washer

Swivelling Cone Hose End

Filter Washer

• Methven recommends this product is installed by a licensed plumber in compliance with all relevant regional regulations.

20±2mm

26mm

max

Step 2

Firmly push the shower rail onto thetop inlet connector and bottomrail connector.

Step 3

Step 4

Fit the elbow cover into the back of the elbowbracket.

Clip into the elbow bracket and overheadshower.

1800

mm

(Recomm

ended)

785mm

FLOOR

Step 1

Install a ½” male nipple at the recommended height.

Overhead

Rail

Hose

Inlet

Bottom RailConnector

Elbow Cover

Handset

Step 6

Make sure a washer is in both ends of theshower hose.

Screw one end of the hose to the bottom of the shower rail, attach handset and place firmly in holder.

It is the responsibility of the installer to ensure a waterproof seal is achieved between the product and mounting surface. If in doubt about the quality of the seal, remove the product and reinstall using silicone to ensure a seal is achieved.

All pipe work must be thoroughly flushed prior to the installation of the hose.

After installation all connections must be checked for leaks.

All outlets used primarily for personal hygiene shall deliver water at a safe temperature as per regional regulations.

IMPORTANT: Please read all of the instructions and turn off water supply before installation.

General:

2

1

Secure in place by tightening the grubscrews firmly using the hex key provided.

Shower

Shower

Connector

Bottom railConnector

Screw the bottom rail connector to awall stud vertically in line with theinlet connector and at the correct distance.

• Wall lining hole should be cut or finished as per the dimension shown in the diagram on the right.

Cut off the threaded nipple 20±2mm from the wall lining and apply thread seal tape to ensure a good seal.

Screw the inlet connector onto the nipple ensuring that the o-ring is sufficiently compressed to createa watertight seal.

Step 5

To adjust slider position, rotate the slider handle to unlock and lock the slider as shown.

Unlock

Lock

Fit overhead shower into elbow bracket and push firmly until the clips engage.

Inlet Connector

Handset

Flat Washer

Swivelling Cone Hose End

Filter Washer

• Methven recommends this product is installed by a licensed plumber in compliance with all relevant regional regulations.

20±2mm

26mm

max

Step 2

Firmly push the shower rail onto thetop inlet connector and bottomrail connector.

Step 3

Step 4

Fit the elbow cover into the back of the elbowbracket.

Clip into the elbow bracket and overheadshower.

1800

mm

(Recomm

ended)

785mm

FLOOR

Step 1

Install a ½” male nipple at the recommended height.

Overhead

Rail

Hose

Inlet

Bottom RailConnector

Elbow Cover

Handset

Step 6

Make sure a washer is in both ends of theshower hose.

Screw one end of the hose to the bottom of the shower rail, attach handset and place firmly in holder.

It is the responsibility of the installer to ensure a waterproof seal is achieved between the product and mounting surface. If in doubt about the quality of the seal, remove the product and reinstall using silicone to ensure a seal is achieved.

All pipe work must be thoroughly flushed prior to the installation of the hose.

After installation all connections must be checked for leaks.

All outlets used primarily for personal hygiene shall deliver water at a safe temperature as per regional regulations.

IMPORTANT: Please read all of the instructions and turn off water supply before installation.

General:

2

1

Secure in place by tightening the grubscrews firmly using the hex key provided.

Shower

Shower

Connector

Bottom railConnector

Screw the bottom rail connector to awall stud vertically in line with theinlet connector and at the correct distance.

• Wall lining hole should be cut or finished as per the dimension shown in the diagram on the right.

Cut off the threaded nipple 20±2mm from the wall lining and apply thread seal tape to ensure a good seal.

Screw the inlet connector onto the nipple ensuring that the o-ring is sufficiently compressed to createa watertight seal.

Step 5

To adjust slider position, rotate the slider handle to unlock and lock the slider as shown.

Unlock

Lock

Fit overhead shower into elbow bracket and push firmly until the clips engage.

Inlet Connector

Handset

Flat Washer

Swivelling Cone Hose End

Filter Washer

• Methven recommends this product is installed by a licensed plumber in compliance with all relevant regional regulations.

20±2mm

26mm

max

Step 2

Firmly push the shower rail onto thetop inlet connector and bottomrail connector.

Step 3

Step 4

Fit the elbow cover into the back of the elbowbracket.

Clip into the elbow bracket and overheadshower.

1800

mm

(Recomm

ended)

785mm

FLOOR

Step 1

Install a ½” male nipple at the recommended height.

Overhead

Rail

Hose

Inlet

Bottom RailConnector

Elbow Cover

Handset

Step 6

Make sure a washer is in both ends of theshower hose.

Screw one end of the hose to the bottom of the shower rail, attach handset and place firmly in holder.

It is the responsibility of the installer to ensure a waterproof seal is achieved between the product and mounting surface. If in doubt about the quality of the seal, remove the product and reinstall using silicone to ensure a seal is achieved.

All pipe work must be thoroughly flushed prior to the installation of the hose.

After installation all connections must be checked for leaks.

All outlets used primarily for personal hygiene shall deliver water at a safe temperature as per regional regulations.

IMPORTANT: Please read all of the instructions and turn off water supply before installation.

General:

2

1

Secure in place by tightening the grubscrews firmly using the hex key provided.

Shower

Shower

Connector

Bottom railConnector

Screw the bottom rail connector to awall stud vertically in line with theinlet connector and at the correct distance.

• Wall lining hole should be cut or finished as per the dimension shown in the diagram on the right.

Cut off the threaded nipple 20±2mm from the wall lining and apply thread seal tape to ensure a good seal.

Screw the inlet connector onto the nipple ensuring that the o-ring is sufficiently compressed to createa watertight seal.

Step 5

To adjust slider position, rotate the slider handle to unlock and lock the slider as shown.

Unlock

Lock

Fit overhead shower into elbow bracket and push firmly until the clips engage.

Inlet Connector

Handset

Flat Washer

Swivelling Cone Hose End

Filter Washer

• Methven recommends this product is installed by a licensed plumber in compliance with all relevant regional regulations.

20±2mm

26mm

max

Step 2

Firmly push the shower rail onto thetop inlet connector and bottomrail connector.

Step 3

Step 4

Fit the elbow cover into the back of the elbowbracket.

Clip into the elbow bracket and overheadshower.

1800

mm

(Recomm

ended)

785mm

FLOOR

Step 1

Install a ½” male nipple at the recommended height.

Overhead

Rail

Hose

Inlet

Bottom RailConnector

Elbow Cover

Handset

Step 6

Make sure a washer is in both ends of theshower hose.

Screw one end of the hose to the bottom of the shower rail, attach handset and place firmly in holder.

It is the responsibility of the installer to ensure a waterproof seal is achieved between the product and mounting surface. If in doubt about the quality of the seal, remove the product and reinstall using silicone to ensure a seal is achieved.

All pipe work must be thoroughly flushed prior to the installation of the hose.

After installation all connections must be checked for leaks.

All outlets used primarily for personal hygiene shall deliver water at a safe temperature as per regional regulations.

IMPORTANT: Please read all of the instructions and turn off water supply before installation.

General:

2

1

Secure in place by tightening the grubscrews firmly using the hex key provided.

Shower

Shower

Connector

Bottom railConnector

Screw the bottom rail connector to awall stud vertically in line with theinlet connector and at the correct distance.

• Wall lining hole should be cut or finished as per the dimension shown in the diagram on the right.

Cut off the threaded nipple 20±2mm from the wall lining and apply thread seal tape to ensure a good seal.

Screw the inlet connector onto the nipple ensuring that the o-ring is sufficiently compressed to createa watertight seal.

Step 5

To adjust slider position, rotate the slider handle to unlock and lock the slider as shown.

Unlock

Lock

Step 3

• Fit overheadshower into elbowbracket and pushfirmly until the clips engage

Step 6

• Make sure a washer is in both ends of the shower hose.

• Screw one end of the hose to the bottom of the shower rail, attach handset and place firmly in holder.

IMPORTANT: Please read all of the instructions and turn off water supply before installation.

page 2 of 4

Page 3: METHVEN AIO AURAJET TWIN SHOWER · Clip into theelbow bracket and overhead shower. • • • • 1800mm (Recommended) 785mm FLOOR. Step 1 Install a ½” male nipple at the recommended

METHVENAIO AURAJET TWIN SHOWER

Plumbers, please ensure a copy of the installation instructions is left with the end user for future reference

Care and Cleaning

Run hot water through shower for 2 minutes before first use.

Never use abrasives or abrasive cleaning agents to clean this product. Clean regularly with contamination free warm soapy water and a damp soft cloth.

Clean filter washer located in the shower hose and in the overhead shower periodically. To access filter washer in overhead shower push down on release button, hold the elbow bracket and pull shower head away from it.

Remove filter washer from the shower head waterway by gently levering out with a small screw driver.

Methven warrants this product against manufacturing defects and that it is suitable for use under the general operating conditions specified in this instruction sheet. However, regional regulations apply and may affect your warranty. Please refer to www.methven.com or call customer service for full details.

New Zealand0800 804 222

Australia1300 638 483

UK0800 195 1602

www.methven.com

Care and Cleaning:

Never use abrasives or abrasive cleaning agents to clean this product. Clean regularly with contamination free warm soapy water and a damp soft cloth.

Clean filter washer located in the shower hose and in the overhead shower periodically. To access

435949 ISSUE A

Technical Specifications: Operating Pressure:Min: 100kPa/1.0barMax: 500kPa/5bar*

Operating Temperature:Hot: Max 70°C*Cold: Min 5°C

Inlet Connections:All ½" BSP

* Regional specific regulations apply. Please refer to your warranty statement at www.methven.com

Installation GuideAURAJET™ SHOWER SYSTEM

Optimum: 150kPa/1.5bar - 500kPa/5bar

If shower performance is compromised by the build-up of lime-scale, soak in limescale

as hydrochloric acid as these can damage the shower. Always rinse the shower thoroughly after cleaning to remove cleaning products that can damage the shower.

Never insert objects into the spray slot or attempt to remove limescale with sharp objects or abrasives.

filter washer in overhead shower push down on release button, hold the elbow bracket and pull

Remove filter washer from the shower head waterwayby gently levering out with a small screw driver.

Do not hang any items or pull down on the overhead shower. This may cause theoverhead shower to deform.

shower head away from it.

remover for up to 10 minutes. Refer to instructions above for how to remove shower head from elbow bracket. Do not use products containing chlorine bleach or hydrochloric acid

1

2

Run hot water through shower for 2 minutes before first use.

page 3 of 4

Page 4: METHVEN AIO AURAJET TWIN SHOWER · Clip into theelbow bracket and overhead shower. • • • • 1800mm (Recommended) 785mm FLOOR. Step 1 Install a ½” male nipple at the recommended

REECE PRODUCT QUALITY GUARANTEEYou have purchased a quality product from Reece Pty Ltd ABN 84 004 097 090 (“Reece”). This product is covered by a Lifetime replacement product warranty, including spare parts, and a 12 month warranty covering labour.

LIFETIME YEAR WARRANTY – DOMESTIC USEThis warranty covers faults in the product construction, material and assembly. Products which are, found upon inspection by an authorised Reece representative, to be defective in construction, material or assembly, will be repaired or exchanged with an equivalent product free of charge. Replaced items become Reece’s property.

All replacement products will be available for collection without charge to the customer at the nearest Reece branch to the customer’s location, or elsewhere as agreed between the customer and Reece.

Labour and Spare PartsThe labour for the replacement of products and spare parts to which this warranty applies will be supplied by Reece or relevant supplier using licensed plumbers engaged by Reece or relevant supplier within 1 year from the date of purchase.

Spare parts found upon inspection by an authorised Reece representative to be defective in construction, material or assembly, will be replaced free of charge for the life of the product.

Warranty ConditionsThis warranty will apply only under all of the following conditions:

• The item has been installed by a licensed plumber

• The item has been installed for and subjected to domesticresidential use only

• Failure is due to a fault in the manufacture of the product

• Proof of purchase (including the date of purchase)is provided

• The installation of the product is in accordance with theinstructions provided

This warranty does not cover products purchased as an ex-display without being fully checked and tested for sale by the manufacturer.

This warranty does not include faults caused by:

• Unsuitable or improper use

• Incorrect installation or installation not in accordance withthe instructions provided

• Installation or part installation by the purchaser or any personother than a LICENSED PLUMBER

• Normal wear and tear

• Inadequate or complete lack of maintenance

• Chemical, electrochemical or electrical influences

• Harsh detergents or abrasive cleaners used onproduct finishes

1 YEAR WARRANTY – COMMERCIAL USE‘Commercial’ use is all use other than for normal domestic residential purposes, including use in non-business places as in public buildings, schools, sports centres and in establishments that contain private bathrooms with high frequency of use by many individuals, such as hotels, motels, retirement villages and hospitals.

The Commercial warranty covers this product against manufacturing faults in the construction, material and assembly of both the finished products and any spare parts for a period of 1 year from the date of purchase. Products and spare parts which are found upon inspection by an authorised Reece representative to be defective in construction, material or assembly will be repaired or exchanged free of charge. Replaced items become Reece’s property. The labour for the replacement of products and spare parts to which this warranty applies will be supplied by Reece or relevant supplier using licensed plumbers engaged by Reece or relevant supplier. The Warranty Conditions and exclusions which apply to the domestic use warranty also apply to this commercial warranty.

EXCLUSIONSTo the fullest extent permitted by law, Reece excludes all liability for damage or injury to any person, damage to any property, and any indirect consequential or other loss or damage.

CLAIM PROCEDUREFor all warranty queries customers are to contact the branch where the product was purchased. These details can be found on your purchase invoice.

Our goods come with guarantees that cannot be excluded under the Australian Consumer Law. You are entitled to a replacement or refund for a major failure and for compensation for any other reasonably foreseeable loss or damage. You are also entitled to have the goods repaired or replaced if the goods fail to be of acceptable quality and the failure does not amount to a major failure.

SH

OW

ER

.ME

TH.T

2.LI

FE

Don’t risk it, use a licensed plumber.™

LIFETIME

QU

ALITY GUARANTEE

page 3 of 3

Don’t risk it, use a licensed plumber.™

page 4 of 4

METHVENAIO AURAJET TWIN SHOWER