Energy efficiency, monitoring and metering
Rob Elder, Keysource
Dr Chris Rudge, University of Leicester
![Page 2: Metering Energy Consumption in Data Centres - Chris Rudge and Rob Elder](https://reader036.fdocuments.us/reader036/viewer/2022062418/5562a906d8b42a6e4f8b4e9a/html5/thumbnails/2.jpg)
• University of Leicester Project Brief
• DCIM explained
• Industry focus and research
• Our DCIM offering
• Core functionality
• Virtualization!
• Closing notes and next actions
Agenda
![Page 3: Metering Energy Consumption in Data Centres - Chris Rudge and Rob Elder](https://reader036.fdocuments.us/reader036/viewer/2022062418/5562a906d8b42a6e4f8b4e9a/html5/thumbnails/3.jpg)
• Centralisation of High Performance Computing
(HPC) across the University
• Creation of Research Computing Team to
support the new service
• Construction of new Data Centre to
accommodate consolidated hardware
• 30 racks with up to 30kW per rack position
• Scalable from 150kW to 300kW IT load
• N+1 resilience
• Modular high efficiency UPS
The Project
“The university recognised
the importance of
efficiency, so wanted a
facility with an annualised
Power Usage Effectiveness
(PUE) of less than 1.5.”
![Page 4: Metering Energy Consumption in Data Centres - Chris Rudge and Rob Elder](https://reader036.fdocuments.us/reader036/viewer/2022062418/5562a906d8b42a6e4f8b4e9a/html5/thumbnails/4.jpg)
Data Centre Solution
![Page 5: Metering Energy Consumption in Data Centres - Chris Rudge and Rob Elder](https://reader036.fdocuments.us/reader036/viewer/2022062418/5562a906d8b42a6e4f8b4e9a/html5/thumbnails/5.jpg)
Keysource
![Page 6: Metering Energy Consumption in Data Centres - Chris Rudge and Rob Elder](https://reader036.fdocuments.us/reader036/viewer/2022062418/5562a906d8b42a6e4f8b4e9a/html5/thumbnails/6.jpg)
Haven’t we come far…
![Page 7: Metering Energy Consumption in Data Centres - Chris Rudge and Rob Elder](https://reader036.fdocuments.us/reader036/viewer/2022062418/5562a906d8b42a6e4f8b4e9a/html5/thumbnails/7.jpg)
… and now we understand so much more
![Page 8: Metering Energy Consumption in Data Centres - Chris Rudge and Rob Elder](https://reader036.fdocuments.us/reader036/viewer/2022062418/5562a906d8b42a6e4f8b4e9a/html5/thumbnails/8.jpg)
Data Centre Infrastructure Management (DCIM)
Data Centre Infrastructure Management (DCIM) covers the integration of the physical M&E
infrastructure (Facilities) with the technology infrastructure (IT), to centralise monitoring,
management and intelligent capacity planning of a data centre’s critical systems.
![Page 9: Metering Energy Consumption in Data Centres - Chris Rudge and Rob Elder](https://reader036.fdocuments.us/reader036/viewer/2022062418/5562a906d8b42a6e4f8b4e9a/html5/thumbnails/9.jpg)
Act Optimize for
efficiency Fix expected
failures Build or
buy capacity
Collect data
Report
Analyze
![Page 10: Metering Energy Consumption in Data Centres - Chris Rudge and Rob Elder](https://reader036.fdocuments.us/reader036/viewer/2022062418/5562a906d8b42a6e4f8b4e9a/html5/thumbnails/10.jpg)
• Monitor everything
• Design it that way – you’ll never add it later
• Monitor for function / failure / alerting
• Monitor for performance / optimisation
• Monitor to understand what it’s doing
• Monitor for service cost
University of Leicester – what to monitor and why?
![Page 11: Metering Energy Consumption in Data Centres - Chris Rudge and Rob Elder](https://reader036.fdocuments.us/reader036/viewer/2022062418/5562a906d8b42a6e4f8b4e9a/html5/thumbnails/11.jpg)
A single solution for all monitoring?
• Not yet…..
– A single product won’t do all of this
• Data centre infrastructure - APC ISX Central
– Proprietary, easy to use, access for Keysource
• General server, network monitoring – OpenNMS
– Free, network & server, customisable
• Specialist HPC - Bright Cluster Manager
– Proprietary, monitoring & management
![Page 12: Metering Energy Consumption in Data Centres - Chris Rudge and Rob Elder](https://reader036.fdocuments.us/reader036/viewer/2022062418/5562a906d8b42a6e4f8b4e9a/html5/thumbnails/12.jpg)
Bespoke views – a better at a glance snapshot
![Page 13: Metering Energy Consumption in Data Centres - Chris Rudge and Rob Elder](https://reader036.fdocuments.us/reader036/viewer/2022062418/5562a906d8b42a6e4f8b4e9a/html5/thumbnails/13.jpg)
IT activity and Data Centre Power
![Page 14: Metering Energy Consumption in Data Centres - Chris Rudge and Rob Elder](https://reader036.fdocuments.us/reader036/viewer/2022062418/5562a906d8b42a6e4f8b4e9a/html5/thumbnails/14.jpg)
Cooling loop tuning
![Page 15: Metering Energy Consumption in Data Centres - Chris Rudge and Rob Elder](https://reader036.fdocuments.us/reader036/viewer/2022062418/5562a906d8b42a6e4f8b4e9a/html5/thumbnails/15.jpg)
Power monitoring at all levels
UPS Loadings Rack Loadings Facility Loadings
![Page 16: Metering Energy Consumption in Data Centres - Chris Rudge and Rob Elder](https://reader036.fdocuments.us/reader036/viewer/2022062418/5562a906d8b42a6e4f8b4e9a/html5/thumbnails/16.jpg)
Proving correct operation
IT Load
Supply
air temp
Pressure
Differential
Control
AHU Fan
speed
Fans adjust
to match IT
air volume
![Page 17: Metering Energy Consumption in Data Centres - Chris Rudge and Rob Elder](https://reader036.fdocuments.us/reader036/viewer/2022062418/5562a906d8b42a6e4f8b4e9a/html5/thumbnails/17.jpg)
Product development
![Page 18: Metering Energy Consumption in Data Centres - Chris Rudge and Rob Elder](https://reader036.fdocuments.us/reader036/viewer/2022062418/5562a906d8b42a6e4f8b4e9a/html5/thumbnails/18.jpg)
DCIM – the next step
Virtual machine manager Operations
COMPUTE
management
Moving VMs
for best productivity
Keeping watch on power and cooling
PHYSICAL
management
Trouble
OK, taking action!
![Page 19: Metering Energy Consumption in Data Centres - Chris Rudge and Rob Elder](https://reader036.fdocuments.us/reader036/viewer/2022062418/5562a906d8b42a6e4f8b4e9a/html5/thumbnails/19.jpg)
Everything, everywhere
![Page 20: Metering Energy Consumption in Data Centres - Chris Rudge and Rob Elder](https://reader036.fdocuments.us/reader036/viewer/2022062418/5562a906d8b42a6e4f8b4e9a/html5/thumbnails/20.jpg)
• We can demonstrate what’s possible
– PUE of <= 1.2 without need for new build
– Rack density of >20KW without water to racks!
– Rack densities do not need to be predetermined
• We have better data to inform decisions
– Power saving features in blades are better than servers
– Investment in an efficient data centre is worthwhile
How does it help others?
![Page 21: Metering Energy Consumption in Data Centres - Chris Rudge and Rob Elder](https://reader036.fdocuments.us/reader036/viewer/2022062418/5562a906d8b42a6e4f8b4e9a/html5/thumbnails/21.jpg)
• Key to securing the University’s position as a
leading research institution
• HPC service has high utilisation with users from
nearly 20 departments from astrophysics, through
genetics to economics
• Has changed the view of researchers demonstrating
that centrally provided services can benefit them
• PUE for last 30 days just 1.17
• Electricity saving, compared to old efficiency, of
approximately £140,000 per year
A successful IT project
What does it REALLY mean?
“This will strengthen
Leicester's position as an
international leader in
computational
astrophysics.”
Justin Read, Lecturer in
Astrophysics
![Page 22: Metering Energy Consumption in Data Centres - Chris Rudge and Rob Elder](https://reader036.fdocuments.us/reader036/viewer/2022062418/5562a906d8b42a6e4f8b4e9a/html5/thumbnails/22.jpg)
Dr. Chris Rudge
Research Computing Services Manager
University of Leicester
0116 252 2223
Rob Elder
Associate Director
Keysource Ltd
0845 204 3333