MEDLEY INGRADE - Insight Lighting
Transcript of MEDLEY INGRADE - Insight Lighting
GROUND MOUNT
UPLIGHT
CONCRETE POUR BOX
INSTALLATION
WHITE & STATIC
COLOR
ACTIVE WHITE
COLOR CHANGING
INSTALLATION INSTRUCTIONS
Insight Lighting Phone: (505)345-0888 Fax: (505)345-3838 Web: www.insightlighting.com
*Insight Lighting reserves the right to make changes to this product and related installation instructions at any time without prior notice.
CAUTION:
INSIGHT LIGHTING IS NOT RESPONSIBLE FOR THE
STRUCTURAL INTEGRITY OF THE BUILDING TO
SUPPORT THE LUMINAIRE. ADDITIONAL BACKING
MAY BE REQUIRED.
CAUTION:
THIS IS AN ELECTRONIC DEVICE. CARE MUST BE TAKEN
DURING STORAGE AND HANDLING. STORE IN A CLEAN, COOL
AND DRY LOCATION. ELECTROSTATIC DISCHARGE (ESD) CAN
HARM THIS PRODUCT. AVOID STATIC DISCHARGE WHILE
HANDLING THIS PRODUCT.
WARNING:
INSTALL PRODUCT IN ACCORDANCE
WITH LOCAL AND NATIONAL ELECTRICAL
CODES.
WARNING:
FAILURE TO COMPLY WITH THE
INSTALLATION INSTRUCTIONS MAY
RESULT IN DEATH OR SERIOUS INJURY
WARNING:
READ ALL SAFETY INSTRUCTIONS
INCLUDED WITH LUMINAIRE BEFORE
INSTALLING LUMINAIRE.
MEDLEY INGRADE
PAGE 1 OF 3
REV AIS11331.DWG 06JUN19 JW
WIRING DETAILS-STARTER KIT
ASSEMBLED VIEW PACKAGE INCLUDES:
ITEMS NEEDED (SUPPLIED BY OTHERS):
(2x) End Caps
Temporary
Concrete Spacer
Assorted
Wire Nuts
Power Cable
(Exterior Rated
Cable)
Ø1-1/2" Underground
Conduit & Connector
Exterior Rated
J-Box
3/8 x 8"
Galvanized Nails
Gravel
Concrete
AC/Data Leader Cable
T-Connector
(For Plug & Play option &
continuous runs only)
Jumper Cable
(For continuous runs
w/spacing only)
Ø1-1/2" Conduit
(by others)
Connector
(by others)
Luminaire
Assembly
Concrete
Pour Box
TYPICAL INSTALLATION (FOR REFERENCE ONLY) STARTER KIT INSTALLATION (FOR REFERENCE ONLY)
THE CERTIFICATE OF INSTALLATION MUST BE COMPLETED, SIGNED AND RETURNED BY THE INSTALLING
CONTRACTOR TO INSIGHT LIGHTING WITHIN 30 DAYS OF COMPLETION OF THE INSTALLATION OF THE MEDLEY
INGRADE PRODUCTS.
3M Epoxy
Resin
Starter Kit
AC In AC In
Data In
Line Black
Ground Green
Neutral White
Data + Red
Data - Orange
Line Black
Ground Green
Neutral White
AC Leader cable
to Luminaire
AC Leader cable
to Luminaire
NON DIMMING 0-10V DIMMING/DMX DAISY CHAIN ACV TERMINATOR INSTALLATION
LINE
BLACK
DATA -
ORANGE
NUETRAL
WHITE
GROUND
GREEN
DATA +
RED
DMX APPLICATIONS
OUTDOOR BELDEN 3105A
DMX APPLICATIONS REQUIRES
THE FOLLOWING CABLE
Ø1-1/2" Conduit &
Connector (by others) to
next luminaire (if applicable)
AC/Data Leader Cable
(ordered separately)
T-Connector (for Plug
& Play option only)
Ø1-1/2" Conduit
(by others)
Connector (by others)
Luminaire
Assembly
Concrete
Pour Box
Ø1-1/2" Conduit &
Connector (by others) to
next luminaire (if applicable)
T-Connector
(for Plug &
Play option
only)
Data Cable
(by others, if necessary)
Starter Kit
AC/Data
Leader Cable
Power Cable (by others)
Data Cable
(Belden 3105A)
Certificate of Installation
Warranty
Phillips Head
Screwdriver
OPTIONAL ITEMS INCLUDED:
(2x) Side Panels
(12x) 8-16x3/4"
Pan Head Screws
Ø1-1/2" Conduit
(by others)
Connector
(by others)
Luminaire
Assembly
Concrete
Pour Box
TYPICAL INSTALLATION SINGLE-NO STARTER KIT (FOR REFERENCE ONLY)
AC/Data Leader Cable
(ordered separately)
ACV Terminator
Output Cable on
last luminaire in run
Plug terminator in
SINGLE-STARTER KIT INSTALLATION (FOR REFERENCE ONLY)
Ø1-1/2" Conduit
(by others)
Connector (by others)
Luminaire
Assembly
Concrete
Pour Box
Ø1-1/2" Conduit &
Connector (by others) to
next luminaire (if applicable)
Jumper Cable
(as needed, ordered
separately)
Data Cable
(by others, if necessary)
Starter Kit
AC/Data
Leader Cable
Power Cable (by others)
3M Epoxy
Resin
1A. Excavate a trench:
-Excavate a trench 18" minimum wide and 6" deep. 6" minimum of space
needed all around the concrete pour box (A).
-A space for gravel (drainage material) (3" x 5" x length of concrete pour
box) should be trenched below and centered on concrete pour box (B). Fill
space with drainage material.
1B. Test drainage material:
-In order to verify the efficiency of the drainage material, an amount of
water equivalent to the volume of the pour box must completely drain within
30 minutes.
-Testing of the drainage material should be done prior to installation of
concrete pour box.
Gravel (drainage material)
INSTALLATION INSTRUCTIONS
Insight Lighting Phone: (505)345-0888 Fax: (505)345-3838 Web: www.insightlighting.com
*Insight Lighting reserves the right to make changes to this product and related installation instructions at any time without prior notice.
CAUTION:
INSIGHT LIGHTING IS NOT RESPONSIBLE FOR THE
STRUCTURAL INTEGRITY OF THE BUILDING TO
SUPPORT THE LUMINAIRE. ADDITIONAL BACKING
MAY BE REQUIRED.
CAUTION:
THIS IS AN ELECTRONIC DEVICE. CARE MUST BE TAKEN
DURING STORAGE AND HANDLING. STORE IN A CLEAN, COOL
AND DRY LOCATION. ELECTROSTATIC DISCHARGE (ESD) CAN
HARM THIS PRODUCT. AVOID STATIC DISCHARGE WHILE
HANDLING THIS PRODUCT.
WARNING:
INSTALL PRODUCT IN ACCORDANCE
WITH LOCAL AND NATIONAL ELECTRICAL
CODES.
WARNING:
FAILURE TO COMPLY WITH THE
INSTALLATION INSTRUCTIONS MAY
RESULT IN DEATH OR SERIOUS INJURY
WARNING:
READ ALL SAFETY INSTRUCTIONS
INCLUDED WITH LUMINAIRE BEFORE
INSTALLING LUMINAIRE.
MEDLEY INGRADE
PAGE 2 OF 3
REV AIS11331.DWG 06JUN19 JW
Ground
1PREPARE GROUND AND TEST DRAINAGE
CONCRETE POUR BOX INSTALL
18" MIN.
(6" MIN. around concrete pour box)
5"
3"
6"
Wall (by others)
6"
STANDARD OPTION
T-Connector (for
continuous runs only)
Jumper cable (for
continuous runs only;
ordered separately)
3-1A. Install conduit:
-Open knockout hole(s) on concrete pour box. Open knockout on opposite
end of pour box for continuous runs (except for the last luminaire in run).
-Install Ø1-1/2" underground conduit with connectors into knockouts on the
concrete pour box.
3-1B. Install cables:
-Install the AC leader cable (ACL-X; ordered separately) through the
conduit and into the first concrete pour box. The j-box should be placed at
a maximum of 24' from the luminaire.
3-1C. Make electrical connections:
-Connect the AC leader cable (ACL-X; ordered separately) to an exterior
rated j-box. Make all electrical connections as per any local and/or NEC
codes in the j-box (See 'Wiring Details'). Test Connections.
-Make sure all open connectors are sealed with cable caps (provided).
FOR CONTINUOUS RUNS ONLY:
-Connect the AC leader cable (ACL-X; ordered separately) to the
T-Connector (provided). Attach the jumper cable (ordered separately) to
the end of the T-Connector and run through the end of the first concrete
pour box, through the conduit and into next pour box. Repeat for all
luminaires in run.
3-1
Conduit with connectors
(by others)
See Wiring Details and
Wiring Layouts for
more information
NOTE
6"
6"
6"
GROUND MOUNT
UPLIGHT
STARTER KIT OPTION
3-2A. Install conduit:
-Open knockout hole(s) on concrete pour box. Open knockout on opposite
end of pour box for continuous runs (except for the last luminaire in run).
-Install Ø1-1/2" underground conduit with connectors into knockouts on the
concrete pour box.
3-2B. Install cables & starter kit:
-Install the exterior rated power & data (if necessary) cables (by others)
through the conduit and into the first concrete pour box.
-Connect the power cable to the starter kit j-box using strain relief
connectors (provided).
3-2C. Make electrical connections:
-Make all electrical connections as per any local and/or NEC codes in the
starter kit j-box (See 'Wiring Details'). Test connections.
-Once connections have been validated, mix 3M resin according to
manufacturer's instructions and pour into starter kit j-box. Install cover with
gasket to the starter kit j-box with 4x screws (provided). Place the starter
kit j-box inside of concrete pour box. (Cover must be installed after resin
has been poured). The 3M resin should be poured in dry weather
conditions and must set for a minimum of 24 hours (See manufacturer's
recommendations).
-Make sure all open connectors are sealed with cable caps (provided).
FOR CONTINUOUS RUNS ONLY:
-Connect the AC leader cable (ACL-X; ordered separately) to the
T-Connector (provided). Attach the jumper cable (ordered separately) to
the end of the T-Connector and run through the end of the first concrete
pour box, through the conduit and into next pour box. Repeat for all
luminaires in run.
3-2
AC leader cable
to starter kit
T-Connector (for
continuous runs only)
Conduit with connectors
(by others)
Starter Kit
Concrete pour box
See Wiring Details and
Wiring Layouts for
more information
NOTE
Power cable
(by others)
Strain relief
WHITE & STATIC
COLOR
ACTIVE WHITE
COLOR CHANGING
2BUILD CONCRETE POUR BOX
2A. Build concrete pour box:
-Attach the end caps to the side panels using (12x) 8-16x3/4" pan head
screws (provided).
-Hand tighten screws to 5in. lbs torque, Max. Do not over tighten screws.
Side panels
End caps
Hand tighten
screws to 5in lbs.
Torque, Max.
NOTE
Do not over tighten
screws
NOTE
(A)
(B)
Cable Cap (required on
all open connectors)
Jumper Cable (for
continuous runs only;
ordered separately)
Data cable
(by others;if
necessary)
CONCRETE POUR BOX
INSTALL
Exterior rated j-box
(by others)
AC leader
cable to j-box
Cable Cap
(required on
all open
connectors)
Conduit with connectors
(by others)
T-Connectors connect on
end-to-end continuous runs
4LEVEL AND INSTALL CONCRETE POUR BOX
4A. Level concrete pour box:
-Level concrete pour box to concrete.
4B. Secure concrete pour box:
-Secure pour box with 3/8" x 8" galvanized nails (by others). See table for
quantity of anchors required per length of pour box.
Wall (by others)
Gravel (drainage material)Ground
LENGTH OF
POUR BOX
1ft
2ft
3ft
3 PER SIDE
4ft
2 PER SIDE
4 PER SIDE
5 PER SIDE
# OF
ANCHORS
INSTALLATION INSTRUCTIONS
Insight Lighting Phone: (505)345-0888 Fax: (505)345-3838 Web: www.insightlighting.com
*Insight Lighting reserves the right to make changes to this product and related installation instructions at any time without prior notice.
CAUTION:
INSIGHT LIGHTING IS NOT RESPONSIBLE FOR THE
STRUCTURAL INTEGRITY OF THE BUILDING TO
SUPPORT THE LUMINAIRE. ADDITIONAL BACKING
MAY BE REQUIRED.
CAUTION:
THIS IS AN ELECTRONIC DEVICE. CARE MUST BE TAKEN
DURING STORAGE AND HANDLING. STORE IN A CLEAN, COOL
AND DRY LOCATION. ELECTROSTATIC DISCHARGE (ESD) CAN
HARM THIS PRODUCT. AVOID STATIC DISCHARGE WHILE
HANDLING THIS PRODUCT.
WARNING:
INSTALL PRODUCT IN ACCORDANCE
WITH LOCAL AND NATIONAL ELECTRICAL
CODES.
WARNING:
FAILURE TO COMPLY WITH THE
INSTALLATION INSTRUCTIONS MAY
RESULT IN DEATH OR SERIOUS INJURY
WARNING:
READ ALL SAFETY INSTRUCTIONS
INCLUDED WITH LUMINAIRE BEFORE
INSTALLING LUMINAIRE.
MEDLEY INGRADE
PAGE 3 OF 3
REV AIS11331.DWG 06JUN19 JW
5 INSTALL CONCRETE SPACER AND POUR CONCRETE
5A. Install concrete spacer:
-Install spacer into pour box by pressing down with hands until it snaps into
place. The top of the spacer and the pour box must be flush (See 'Detail
-A-').
-The spacer is not intended to hold weight of any kind.
5B. Pour concrete:
-Backfill trench with concrete 6" minimum around concrete pour box.
Concrete should be level with the top of the concrete pour box.
-Allow concrete to cure and dry per concrete specifications, before moving
on to the next step.
-Remove all debris from the top of the spacer that may prevent its removal.
Concrete to be level with
top of concrete pour box
Wall (by others)
GROUND MOUNT
UPLIGHT
Gravel (drainage material)GroundConcrete
Detail -A-
Spacer to be flush
with pour box
WHITE & STATIC
COLOR
ACTIVE WHITE
COLOR CHANGING
12"
14-3/8"
12" 12"
26-3/8"
12" 12" 12"
38-3/8"
12" 12" 12" 12"
50-3/8"
SNAP!
6 FILL OUT AND COMPLETE CERTIFICATE OF INSTALLATION
6A. Fill out warranty form:
-Fill out and complete attached certificate of installation.
-The certificate of installation must be returned within 30 days to Insight
Lighting upon the installation of the Medley Ingrade product(s). Failure to
return this certificate duly completed and signed, shall void the standard
5-year limited warranty.
CONCRETE POUR BOX
INSTALL
CERTIFICATE OF
INSTALLATION
INSIGHT MEDLEY INGRADE CERTIFICATE OF INSTALLATION
THIS CERTIFICATE OF INSTALLATION MUST BE COMPLETED, SIGNED AND RETURNED BY THE INSTALLING CONTRACTOR TO INSIGHT LIGHTING 30 DAYS AFTER COMPLETION OF THE INSTALLATION OF INSIGHT MEDLEY INGRADE PRODUCTS.
FAILURE TO RETURN THIS CERTIFICATE OF INSTALLATION, DULY COMPLETED AND SIGNED, SHALL VOID THE STANDARD 5-YEAR LIMITED WARRANTY WITH REGARD TO THE MEDLEY INGRADE PRODUCTS SHIPPED PURSUANT TO THE PROJECT NAME AND DISTRIBUTOR PURCHASE ORDER INDICATED BELOW.
This certificate of installation certifies that the Medley Ingrade products manufactured by INSIGHT LIGHTING and shipped pursuant to the following project name/distributor PO were installed by the undersigned installing contractor as per the products’ installation instructions provided in shipment with the products:
PROJECT NAME: _________________________________________
DISTRIBUTOR PO#: _______________________________________
In accordance with the INSIGHT LIGHTING Terms and Conditions, a duly completed and signed certificate of installation must be returned to INSIGHT LIGHTING in order for the Medley Ingrade products shipped pursuant to the above-mentioned project name and distributor purchase order to be covered by the INSIGHT LIGHTING standard 5-year limited warranty set forth in the INSIGHT LIGHTING Terms and Conditions available at:
www.insightlighting.com/terms-and-conditions/
Certificates of installation may be returned as follows: - PDF emailed to: [email protected]
Signed this day of , _________ day of _______________, 20
Signature: ____________________________________________________________________________
Name and title of: ______________________________________________________________________
Full legal name and address of company installing Medley Ingrade Products
________________________________________________________
________________________________________________________
________________________________________________________
INSIGHT MEDLEY INGRADE CERTIFICATE OF INSTALLATION
THIS CERTIFICATE OF INSTALLATION MUST BE COMPLETED, SIGNED AND RETURNED BY THE INSTALLING CONTRACTOR TO INSIGHT LIGHTING 30 DAYS AFTER COMPLETION OF THE INSTALLATION OF INSIGHT MEDLEY INGRADE PRODUCTS.
FAILURE TO RETURN THIS CERTIFICATE OF INSTALLATION, DULY COMPLETED AND SIGNED, SHALL VOID THE STANDARD 5-YEAR LIMITED WARRANTY WITH REGARD TO THE MEDLEY INGRADE PRODUCTS SHIPPED PURSUANT TO THE PROJECT NAME AND DISTRIBUTOR PURCHASE ORDER INDICATED BELOW.
This certificate of installation certifies that the Medley Ingrade products manufactured by INSIGHT LIGHTING and shipped pursuant to the following project name/distributor PO were installed by the undersigned installing contractor as per the products’ installation instructions provided in shipment with the products:
PROJECT NAME: _________________________________________
DISTRIBUTOR PO#: _______________________________________
In accordance with the INSIGHT LIGHTING Terms and Conditions, a duly completed and signed certificate of installation must be returned to INSIGHT LIGHTING in order for the Medley Ingrade products shipped pursuant to the above-mentioned project name and distributor purchase order to be covered by the INSIGHT LIGHTING standard 5-year limited warranty set forth in the INSIGHT LIGHTING Terms and Conditions available at:
www.insightlighting.com/terms-and-conditions/
Certificates of installation may be returned as follows: - PDF emailed to: [email protected]
Signed this day of , _________ day of _______________, 20
Signature: ____________________________________________________________________________
Name and title of: ______________________________________________________________________
Full legal name and address of company installing Medley Ingrade Products
________________________________________________________
________________________________________________________
________________________________________________________