Mechatronic flow sensor for high Fluid sensors and ...Measurement of liquids up to 180 C. Process...

2
Measurement of liquids up to 180 °C. Process cooling in an induction furnace. Mechatronic flow sensor The flow sensor works to the principle of spring-support- ed piston: the piston, located in the valve seat in the housing, is lifted by the flowing medium against the spring resistance. The piston position is monitored via a magnetic-field sensor and is output as an analogue signal. The spring resistance forces the piston to return to its original position with decreasing flow. This ensures posi- tion-independent installation of the flow sensor preven- ting backflow. Due to the temperature decoupling of the transducer from the electronics, this sensor is especially suitable for media in high temperature applications of up to 180 °C. The units are maintenance-free. product news For flow ranges of 0.3...25 l/min. Analogue output signal 4...20 mA. Simple and robust. Fast response time ≤ 10ms. Pressure ranges up to 15 bar. Mechatronic flow sensor for high temperatures. Fluid sensors and diagnostic systems bus, identification and control systems fluid sensors and diagnostic systems position sensors and object recognition 3e Str. SBT 12.qxd 15.03.2012 10:48 Uhr Seite 2

Transcript of Mechatronic flow sensor for high Fluid sensors and ...Measurement of liquids up to 180 C. Process...

Page 1: Mechatronic flow sensor for high Fluid sensors and ...Measurement of liquids up to 180 C. Process cooling in an induction furnace. Mechatronic flow sensor The flow sensor works to

Measurement of liquidsup to 180 °C.

Process cooling in an induction furnace.

Mechatronic flow sensorThe flow sensor works to the principle of spring-support-ed piston: the piston, located in the valve seat in thehousing, is lifted by the flowing medium against thespring resistance. The piston position is monitored via amagnetic-field sensor and is output as an analogue signal.The spring resistance forces the piston to return to itsoriginal position with decreasing flow. This ensures posi-tion-independent installation of the flow sensor preven-ting backflow.Due to the temperature decoupling of the transducerfrom the electronics, this sensor is especially suitable formedia in high temperature applications of up to 180 °C.The units are maintenance-free.

product news

For flow ranges of 0.3...25 l/min.

Analogue output signal 4...20 mA.

Simple and robust.

Fast response time ≤ 10ms.

Pressure ranges up to 15 bar.

Mechatronic flow sensor for hightemperatures.

Flu

id s

enso

rs a

nd

dia

gn

ost

ic s

yste

ms

bus,identification

and control systems

fluid sensors and diagnostic

systems

position sensors

and objectrecognition

3e Str. SBT 12.qxd 15.03.2012 10:48 Uhr Seite 2

Page 2: Mechatronic flow sensor for high Fluid sensors and ...Measurement of liquids up to 180 C. Process cooling in an induction furnace. Mechatronic flow sensor The flow sensor works to

Common technical data

Operating voltage [V] 24 DC (-15 % / + 10 %)

Short-circuit protection •

Materials in contactwith the medium

stainless steel 304/1.4301;nickel-plated brass;

PPS;O-ring: FPM

Ambient temperature [°C] 0...60

Response time [s] < 0.01

Current consumption [mA] < 30

Reverse polarity / overload protection • / •

TypeSBT, SBM

Dimensions

3565

M12x1

M12x1

1376,5

13

Rp

43

Rp

43

L+

L

1

3

2

Wiring

SBT633

Processconnection

Mediumtemperature

[°C]

Accuracy

[% of the final value]

Pressureresistance

[bar]

Orderno.

Connection cable 0.3 m with M12 connector · analogue function mode 4...20 mA

Rp 3/4 20...180 ± 5 15 SBT633

Protection rating,protection class

IP 67, III

G 3/4 20...180

Measuring range

[l/min]

0.3...25

0.3...25 ± 5 15 SBM613*IP 67, III

Applications:Liquids (water, glycol solutions).

* Only measuring insert for OEM solutions, no replacement part.35

65

M12x1

M12x1

20

4070

47157

30

G 43

SBM613

43

2 1

Thermographicdiagramof an SBT typeflow sensor.

Flu

id s

enso

rs a

nd

dia

gn

ost

ic s

yste

ms

Flow sensors

For further technical data please go to: www.ifm.com

ifm a

rtic

le n

o. 7

5114

68 ·

Prin

ted

in G

erm

any

on n

on-c

hlor

ine

pape

r. ·

We

rese

rve

the

right

to

mak

e te

chni

cal a

ltera

tions

with

out

prio

r no

tice.

· 04

.201

2

3e Str. SBT 12.qxd 15.03.2012 10:48 Uhr Seite 3