Measuring technology for compressed air and...

4
www.cs-instruments.com Flow Dew point Data loggers Pressure Leakage Current Compressed air quality Measuring technology for compressed air and gases

Transcript of Measuring technology for compressed air and...

Page 1: Measuring technology for compressed air and gasesdonar.messe.de/exhibitor/hannovermesse/2017/A... · Flow Dew point • The flow sensors VA 5xx work according to the calorimetric

www.cs-instruments.com

Flow

Dew point

Data loggers

Pressure

Leakage

Current

Compressed air quality

Measuring technologyfor compressed air and gases

Page 2: Measuring technology for compressed air and gasesdonar.messe.de/exhibitor/hannovermesse/2017/A... · Flow Dew point • The flow sensors VA 5xx work according to the calorimetric

Flow

Dew point

• TheflowsensorsVA5xxworkaccordingtothecalorimetric measuring principle.

• Therefore, an additional temperature and pressure compensation is not necessary.

• The sensors can be used for compressed airandgaseslikeN2,O2,H2,,He,CH4,Ar,Vacuum…

• Besideactualflow(m3/h)andtotalflow(m3)also the temperature is measured. Units can be adapted individually via display or data logger.

• Asstandardoutputsignals4…20mA,pulse,M-Bus and Modbus RTU are available. Other bus protocols on request.

• VA500isaninsertiontypesensorusablefrom½” to > 12”. The sensor has to be installed via ½” ball valve. The installation is possible under pressure.Alsogoodformobilemeasurement.

• VA520alreadycomeswithmeasuringsectionavailablewithflangeorthread(1/4”-2”)

• VA550/570areusableforheavydutyapplications,outdoorinstallationorATEXareas.

Leakage

• ThedewpointsensorsFA5xxareapplicableforcompressedair,N2,O2,Ar,CO2,naturalgas,biogas…

• Thesensorscanmeasuredownto-80°Ctddepending on customer application. Thehumiditycanalsobeshownindifferentunits(ppm,g/m³...)

• FA510/515:4…20mAand/orModbusRTUoutput signal in parallel

• FA500:4…20mAandModbusRTUoutputsignal in parallel, integrated display and alarm relay.

• These sensors can be mounted via thread or measuringchamber(quickcoupling).

• Measuring chamber has to be chosen depending on line pressure.

• TheportabledewpointsensorDP500withintegrated data logger is the ideal service instrument for mobile dew point measurement downto-80°Ctd.

www.cs-instruments.com

Page 3: Measuring technology for compressed air and gasesdonar.messe.de/exhibitor/hannovermesse/2017/A... · Flow Dew point • The flow sensors VA 5xx work according to the calorimetric

Data loggers

Leakage

• BymeansoftheLD400eventhesmallestleakages in compressed air lines, gas, vapor and vacuum plants or refrigeration plants can be detected even from distances of several meters.

• LD400transformstheinaudiblesignalsintoafrequencywhichcanbeidentified.Bymeansof the comfortable sound-proof headset these noisescanberealizedeveninextremelynoisy environments.

• Robustness and the little weight ensure a fatigue-proof use in industrial environments

• The data loggers enable recording of all measuring data of CS Instruments and third party sensors.

• There are mobile and stationary solutions available.TheportfoliostartswithPI500withonesensorinputonboard.DS400isavailableupto4sensorinputsandDS500upto12sensor inputs.

• The measured values can transferred via USB stickorEthernetconnectiontothecomputer.For data evaluation there is CS Soft Basic software.

• Important functions are automatic consumption reports, remote monitoring of the data via webserver, alarm management or energy analysis.

www.cs-instruments.com

Page 4: Measuring technology for compressed air and gasesdonar.messe.de/exhibitor/hannovermesse/2017/A... · Flow Dew point • The flow sensors VA 5xx work according to the calorimetric

HEADQUARTER GERMANYCS INSTRUMENTS GMbHZindelsteinerStraße1578052VS-TannheimGermanyP:+497705978990F:+4977059789920E:[email protected]

Compressed air quality

• The residual oil content sensor OIL check measure the residual oil content in compressed air. By means ofsampletakingarepresentativepartvolumeflowistaken from the compressed air. Due to the

continuousmeasurementthresholdvalueexceeding will be recognized immediately.

• TheparticlecounterPC400measuresparticlesfromsize0.1µmto5µm.Filterperforationsdonotremainundetected.

• The dew point sensors measure the pressure dew pointdownto-80°Ctd.Alsointhiscasethealertistriggered if the dryer breaks down.

• The centerpiece of quality measurement is the DS500.Theintegrateddataloggerstoresthemeasured safely and reliable. The threshold values can be freely entered. 4 alarm relays are availableforautomaticalarmsincaseofexceedingthe threshold values.

www.cs-instruments.com