Measurement of protons for correlation functions using the ...

1
Acknowledgments Measurement of protons for correlation functions using the newly upgraded FAUSTUPS Lauren Heilborn, Alan B. McIntosh, Mike Youngs, Layla Bakhtiari, Larry W. May, Ellen McCleskey, Andrea Jedele, Andrew Zarrella, Sherry J. Yennello Cyclotron Institute, Texas A&M University Abstract Proton-proton (pp) correlation functions have been predicted to be sensitive to the density-dependence of the asymmetry energy in the nuclear equation of state. We have upgraded the FAUST with position- sensitive delta-E silicon detectors, to measure correlation functions with high resolution. We developed a methodology for accurate position calibration. Light charged particles produced in the reactions of 40 Ar+ 70 Zn, 58 Fe and 40 Ca+ 58 Ni at 40 MeV/nucleon have been measured in the resultant Forward Array Using Silicon Technology with Upgraded Position Sensitivity (FAUSTUPS). These systems were chosen to allow the asymmetry to vary while holding either the Z or the A constant. The resolution achieved in this campaign and progress on the calibration is demonstrated. Literature: Proton-Proton Correlation Functions [2] S. N. Soisson, et al., NIM A, 613, 240 (2010). FAUSTUPS: Forward Array Using Silicon Technology with Upgraded Position Sensitivity Uses existing CsI(Tl)/PD E detectors [1] Dual-Axis Dual-Lateral (DADL) detectors improve angular resolution [2] 4 signals per silicon ASIC HINP Chips & new cabling/biasing scheme to accommodate additional signals [3] Signal split across surface requires higher-gain preamps (~110mV/MeV), to pick up higher energy LCPs [4] Position Resolution < 200 um Energy Resolution < 2 % Interferometry, patterns in relative proton momenta, due to the interactions between any 2 protons in the same event Correlation Functions sensitive to the asymmetry energy Direct interaction between the 2 protons in the reaction Good Angular Resolution Important Position Calibration Method [3] G. Engel, et al., NIM A, 652, 462 (2011). [4] R. Todd, RIS-Corp., 5905 Weisbrook Lane, Suite 102, Knoxville, TN 37909 (2013). Need a measure of relative detector position for acceptable angular resolution 0.040” tungsten mask machined by wire EDM Center hole for beam Stripes (0.010”) Each stripe angled to hit detector behind Positioned on Front Plate of FAUST Collimated Au Target, elastically scattered 15 MeV/nucleon alphas (rings A & B) Collimated Th Source (rings C-E) Align stripes Current Status 40A MeV 40 Ar+ 70 Zn, 58 Fe and 40 Ca+ 58 Ni Clear p,d,t delineation in dE-E Plots Require all 4 signals For 3-Signal events on a detector, can recreate expected 4 th signal Front1+Front2 = Back1 + Back2 Experimental Details [9] P. Cammarata, et al., NIMA, 792, 61-66 (2015). Thank you to the Cyclotron Institute, RIS Corporation and Micron Semiconductor, Ltd. This work supported by grants from: Robert A. Welch Foundation Grant #A-1266, Department of Energy Grant # DE-FG03-93ER40773 and NSF Grant # NSF-PHY 1263281. FAUSTUPS Hardware FAUSTUPS Electronics All Data Collected (November 2014-March 2015) Calibration Data Collected Si Energy Calibration Completed CsI Energy Calibration Particle Identification Position Calibration Extract Correlation Functions Compare to Simulations [1] F. Gimeno-Nogues, et al., NIM A, 399, 94 (1997). Array shows good Si energy resolution Calibration Beams Energy (p+alpha @ 10 A MeV) Position (See Upper Right) ! q Re l = 1 2 ! p 1 ! p 2 C ( ! q Re l ) = N Y c ( q Re l ) Y nc ( q Re l ) [9] PID Value [5] [5] D.H. Boal, et al., Rev. of Mod. Phys., 62, 553 (1990). [6] G. Verde et al., Eur. phys. j. a 30, 81 (2006). [7] R. Ghetti, et al., Nuclear Physics A 674, 277 (2000). [8] L. W. Chen et al., Phys. Rev. C 68, 014605 (2003). S. Koonin, Phys. Lett. B, 70, 43 (1977). S. Pratt and M. B. Tsang, Phys. Rev. C 36, 2390 (1987). [8] [7] [6] System # Events Events w/ 2 or more protons Events w/ 3 or more protons 40 Ar+ 58 Fe 31M 254k 16k 40 Ar+ 70 Zn 44M 542k 28k 40 Ca+ 58 Ni 84M 1.3M 172k TOTAL 161M 2.1M 216k

Transcript of Measurement of protons for correlation functions using the ...

Page 1: Measurement of protons for correlation functions using the ...

Acknowledgments

Measurement of protons for correlation functions using the newly upgraded FAUSTUPS

Lauren Heilborn, Alan B. McIntosh, Mike Youngs, Layla Bakhtiari, Larry W. May, Ellen McCleskey, Andrea Jedele, Andrew Zarrella, Sherry J. Yennello

Cyclotron Institute, Texas A&M University

Abstract

Proton-proton (pp) correlation functions have been predicted to be sensitive to the density-dependence of the asymmetry energy in the nuclear equation of state. We have upgraded the FAUST with position-sensitive delta-E silicon detectors, to measure correlation functions with high resolution. We developed a methodology for accurate position calibration. Light charged particles produced in the reactions of 40Ar+70Zn,58Fe and 40Ca+58Ni at 40 MeV/nucleon have been measured in the resultant Forward Array Using Silicon Technology with Upgraded Position Sensitivity (FAUSTUPS). These systems were chosen to allow the asymmetry to vary while holding either the Z or the A constant. The resolution achieved in this campaign and progress on the calibration is demonstrated.

Literature: Proton-Proton Correlation Functions

[2] S. N. Soisson, et al., NIM A, 613, 240 (2010).

for two charged particles. The open markers have a denominator (eq. 6) constructed by

the “event-mixing” technique, the closed markers use the “singles-product”. No appreciable

di↵erence is observed, demonstrating that either technique may be utilized for constructing

the correlation function, without a↵ecting the basic shape.

FIG. 7. The open markers have a denominator (eq. 6) constructed by the “event-mixing” technique,

the closed markers use the “singles-product”. No appreciable di↵erence is observed between the

two methods. It is of note that these correlation functions were extracted only from particular

detectors that were “equidistant” [9].

Henzl et al. has obtained pp correlation functions cut on in-lab angle from 80 MeV/A re-

actions of 40Ca+40Ca and 48Ca+48Ca [10]. Figure 8 shows the resultant correlation functions

from the two reactions, cut into two bins of total momentum. These correlation functions

are further cut by the angle, and compared to two di↵erent techniques of simulating the size

of the source. The highest angle exhibits the largest correlation.

10

FAUSTUPS: Forward Array Using Silicon Technology with Upgraded Position Sensitivity

u Uses existing CsI(Tl)/PD E detectors [1]

u Dual-Axis Dual-Lateral (DADL) detectors improve angular resolution [2] §  4 signals per silicon

u ASIC HINP Chips & new cabling/biasing scheme to accommodate additional signals [3]

u Signal split across surface requires higher-gain preamps (~110mV/MeV), to pick up higher energy LCPs [4]

u Position Resolution < 200 um

u Energy Resolution < 2 %

u Interferometry, patterns in relative proton momenta, due to the interactions between any 2 protons in the same event

u Correlation Functions sensitive to the asymmetry energy

u Direct interaction between the 2 protons in the reaction

u Good Angular Resolution Important

Position Calibration Method

[3] G. Engel, et al., NIM A, 652, 462 (2011). [4] R. Todd, RIS-Corp., 5905 Weisbrook Lane, Suite 102, Knoxville, TN 37909 (2013).

u Need a measure of relative detector position for acceptable angular resolution

u 0.040” tungsten mask machined by wire EDM

§  Center hole for beam

§  Stripes

z  (0.010”)

z  Each stripe angled to hit detector behind

u Positioned on Front Plate of FAUST

u Collimated Au Target, elastically scattered 15 MeV/nucleon alphas (rings A & B)

u Collimated Th Source (rings C-E)

u Align stripes

Current Status

u 40A MeV 40Ar+70Zn,58Fe and 40Ca+58Ni

u Clear p,d,t delineation in dE-E Plots

u Require all 4 signals

u For 3-Signal events on a detector, can recreate expected 4th signal

u Front1+Front2 = Back1 + Back2

Experimental Details

[9] P. Cammarata, et al., NIMA, 792, 61-66 (2015).

Thank you to the Cyclotron Institute, RIS Corporation and Micron Semiconductor, Ltd. This work supported by grants from: Robert A. Welch Foundation Grant #A-1266, Department of Energy Grant # DE-FG03-93ER40773 and NSF Grant # NSF-PHY 1263281.

þ  FAUSTUPS Hardware þ  FAUSTUPS Electronics þ  All Data Collected (November

2014-March 2015) þ  Calibration Data Collected þ  Si Energy Calibration

Completed Ø  CsI Energy Calibration Ø  Particle Identification q  Position Calibration

q  Extract Correlation Functions q  Compare to Simulations

[1] F. Gimeno-Nogues, et al., NIM A, 399, 94 (1997).

u Array shows good Si energy resolution

u Calibration Beams

§  Energy (p+alpha @ 10 A MeV)

§  Position (See Upper Right)

!qRe l =12!p1 −!p2

C(!qRe l ) = NYc (qRe l )Ync (qRe l )

[9]

PID Value

[5]

[5] D.H. Boal, et al., Rev. of Mod. Phys., 62, 553 (1990). [6] G. Verde et al., Eur. phys. j. a 30, 81 (2006). [7] R. Ghetti, et al., Nuclear Physics A 674, 277 (2000).

[8] L. W. Chen et al., Phys. Rev. C 68, 014605 (2003). S. Koonin, Phys. Lett. B, 70, 43 (1977). S. Pratt and M. B. Tsang, Phys. Rev. C 36, 2390 (1987).

[8] [7]

[6]

System # Events Events w/ 2 or more protons

Events w/ 3 or more protons

40Ar+58Fe 31M 254k 16k 40Ar+70Zn 44M 542k 28k 40Ca+58Ni 84M 1.3M 172k TOTAL 161M 2.1M 216k