IESNA LM-79: 2008 Measurement and Test Report
for
Green Venture Group Ltd. 14/F, Wing Hing Commercial Building, 16-18 Sutherland Street, Sheung Wan, Hong Kong
Aug 02, 2012
Product Name: V-Shape Light 1200
Model No: MG-XVL-1200
Test Engineer: David Zhang ~~_A
Report No.: BTR66.181.12.124.02
Sample Received Date: Ju128, 2012
Test Performed Date: Ju130, 2012
Reviewed By: Steven Hsu
Prepared By: BEST Test Service Shenzhen Co., Ltd. 1st Floor, 1st Building, Weitai Industrial Park, Yingrenshi, Shiyan,
. Baoan, Shenzhen, China
TEL: +86-755-28236006
FAX: +86-755-23467087-811
Email: [email protected]
~W~&\UlI® Efficient Lighting Initiative
NVLAP LAB CODE 200770-~ Note: The test report only allows to be revised within the retention period unless further standard or the requirement was noticed. This report is for the exclusive use of BEST's Client and is provided pursuant to the agreement between BEST and its Client. BEST's responsibility and Liability are limited to the terms and conditions of the agreement. BEST assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this report. Only the Client is authorized to permit copying or distribution of this report and then only in its entirety. Any use of the BEST name or one of its marks for the sale or advertisement of the tested material, product or service must first be approved in writing by BEST. The observations and test results in this report are relevant only to the sample tested. This report by itself does not cover that the material, product, of service is or has ever been under a BEST certification program. National Voluntary Laboratory Accreditation Program (NVLAP) has accredited this laboratory under IS017025: 2005 for specific laboratory activities as listed in the NVLAP directory of accredited laboratories. The results shown in this report were determined by this laboratory in accordance with its terms of accreditation.
Green Venture Group Ltd. Model: MG-XVL-1200
Report No.BTR66.181.12.124.02 Page 2 of 9 IESNA LM-79 Test Report
TABLE OF CONTENTS
1 - GENERAL INFORMATION ................................................................................................................................... 3
1.1 PRODUCT DESCRIPTION FOR EQUIPMENT UNDER TEST (EUT) ......................................................................... 3 1.2 OBJECTIVE ........................................................................................................................................................... 3 1.3 TEST FACILITY DESCRIPTION ............................................................................................................................... 3 1.4 TEST EQUIPMENT LIST ......................................................................................................................................... 4
2 - TEST METHOD ....................................................................................................................................................... 5
3 – SUMMARY OF TEST RESULT ........................................................................................................................... 6
4 – SPECTRAL FLUX PLOTS ................................................................................................................................... 7
5 – EUT PHOTOS......................................................................................................................................................... 8
6 – LUMINOUS INTENSITY DISTRIBUTION TEST PLOTS (CIE CHROMATICITY) ....................................... 9
Green Venture Group Ltd. Model: MG-XVL-1200
Report No.BTR66.181.12.124.02 Page 3 of 9 IESNA LM-79 Test Report
1 - GENERAL INFORMATION 1.1 Product Description for Equipment under Test (EUT)
Applicant : Green Venture Group Ltd. Product Name : V-Shape Light 1200 Model No : MG-XVL-1200 Brand : MAXGREEN Nominal Operation Voltage : AC100-240V; 50/60 Hz Nominal Power : 50W Nominal CCT : 4300K Nominal CRI : 75 Nominal Lumen Output : 4770 Lumens Nominal Life Time : 50000 Hours Number of hours operated prior to measurement for new sample
: 0 Hours
Stabilization Time : 1.5 hours Total operating time for measurement include stabilization time
: 3.5hours
Date of Receiving Sample : Jul 28, 2012 Measurement quantities measured : 1 pcs Orientation During Testing : Horizontal Test Requested
: 1. Electrical and Photometric Test 2. Luminous Intensity Distribution Test; 3. THD.
1.2 Objective The following test report is prepared on behalf of Green Venture Group Ltd. in accordance with IESNA LM-79-08, used
the following American National Standards or illumination Engineering Society of North America test guides: ANSI C78.377-2008: Specifications for the Chromaticity of Solid State Lighting Products;
ANSI C79.1– 2002: American National Standard for Electric Lamps – Nomenclature for Glass Bulbs Intended for Use
with Electric Lamps;
ANSI C78.20 – 2003: American National Standard for Electric Lamps – A, G, PS, and Similar Shapes with E26
Medium Screw Bases;
ANSI C78.21 – 2003: American National Standard for Electric Lamps – PAR and R Shapes;
ANSI C78.24 – 2001: American National Standard for Electric Lamps – Two-inch (51 mm);
Integral-reflector Lamps with Front Covers and GU5.3 or GX 5.3 Bases;
ANSI/IEC C81.61-2003: American National Standard for Electric Lamp Bases;
ANSI/IEEE C62.41 – 1991 (01-May-1991): Surge Voltages in Low-Voltage AC Power Circuits, Recommended Practice
for;
CIE Publication No. 13.3 – 1995: Method of Measuring and Specifying Color Rendering of Light Sources;
CIE Publication No. 18.2 – 1983: The Basis of Physical Photometry;
IESNA LM-16-1993: Practical Guide to Colorimetry of Light Sources;
IESNA LM-28-89 – 1989: Guide for the Selection, Care, and Use of Electrical Instruments in the Photometric
Laboratory;
IESNA LM-79-08 Electrical and Photometric Measurement of Solid State Lighting Products
UL 1993 – 1999: Standard for Self-Ballasted Lamps and Lamp Adapters;
UL 8750 – 2009: Light Emitting Diode (LED) Equipment for Use in Lighting Products. 1.3 Test Facility Description The Energy Efficiency Lab used by BEST to collect energy efficiency measurement data is located in 1st Floor, 1st
Building, Weitai Industrial Park, Yingrenshi, Shiyan, Baoan, Shenzhen, China. BEST Test Service Shenzhen Co., Ltd
is a National Institute of Standards and Technology (NIST) accredited laboratory, under the National Voluntary
Laboratory Accredited Program (Lab Code 200770-0). BEST Test Service Shenzhen Co., Ltd is also an ELI accredited
lab for lighting products (ELI Certificate No. ELI-L04-2010) and UL accredited lab for lighting products
Green Venture Group Ltd. Model: MG-XVL-1200
Report No.BTR66.181.12.124.02 Page 4 of 9 IESNA LM-79 Test Report
1.4 Test Equipment List
Device Manufacture Model No Serial No Cal. Date Cal Due Date
Integral Sphere Everfine 1.5M
SPEKTRON 608040T Oct 20, 2011 Oct 20, 2012
Integral Sphere Everfine 1.5M
SPEKTRON 906025 Oct 20, 2011 Oct 20, 2012
Integral Sphere Labsphere LMS-650 6101002416 Mar 10, 2012 Mar 09, 2013
Spectro Meter Assy Labsphere CDS 2100 217101416 Mar 10, 2012 Mar 09, 2013
Plus UV-VIS-Near IR Spectrophotometer
Colorimeter Everfine
PMS-80-V1 (380nm-800nm)
608033 Oct 20, 2011 Oct 20, 2012
Plus UV-VIS-Near IR Spectrophotometer
Colorimeter Everfine
PMS-700 (200nm-800nm)
908001 Oct 20, 2011 Oct 20, 2012
Goniophotometer Everfine GOR-5000 1009001 Nov 20, 2011 Nov 19, 2012
6 1/2 Digital Multimeter Agilent 34401A MY4702386 Oct 18, 2011 Oct 17, 2012
AC Power Source California Instrument
1501I S13093 N/A N/A
AC Power Source California Instrument
1501L L03572 N/A N/A
Standard Light Source OSRAM 24V/50W NO.1 Sep 17, 2011 Sep 16, 2012
Standard Light Source OSRAM 24V/50W NO.2 Sep 17, 2011 Sep 16, 2012
Multi-Function AC standard Meter
Everfine PF2010S 605010 Oct 18, 2011 Oct 17, 2012
Digital Power Meter Everfine PF9811 902029 Oct 18, 2011 Oct 17, 2012
Digital Power Meter YOKOGAWA WT210 91K310009 Oct 18, 2011 Oct 17, 2012
Digital Power Meter YOKOGAWA WT210 91K310017 Oct 18, 2011 Oct 17, 2012
Digital Power Meter YOKOGAWA WT210 91K310016 Oct 18, 2011 Oct 17, 2012
Ballast Parameter Analyzer
Everfine PF9821 905050 Oct 18, 2011 Oct 17, 2012
Second Meter TIANFU PC 396 N/A Oct 18, 2011 Oct 17, 2012
Digital Storage Oscilloscope
Tektronix TDS2012B C051911 Oct 18, 2011 Oct 17, 2012
Statement of Traceability: BEST Test Service Shenzhen Co., Ltd. certifies that all calibration has been performed using suitable standards traceable to the NIM China.
Green Venture Group Ltd. Model: MG-XVL-1200
Report No.BTR66.181.12.124.02 Page 5 of 9 IESNA LM-79 Test Report
2 - Test Method 2.1 Photometric and Electrical Measurement (Integrated Sphere Method) Total light output (luminous flux) for the 25℃ ±1℃ ambient temperature conditions is measured using an Everfine integrating sphere. Temperature is measured at a position inside the sphere. Spectral radiant flux measurements are made using PMS-80-V1 to the detector port of the integrating sphere. Each lamp is operated at rated voltage in its designated orientation. Each lamp should be stable before measurements are made. The determining method of stable is as follows: Step 1 Take 3 measurements of the lamp light output at 15 minute interval (total time=30mintues.)This time period is in addition to the recommended pre-burning time. Step 2 Calculate the percent difference between the maximum measured value and the minimum measured value for the three consecutive measurements. Step 3 if the value calculated in Step 2 does not exceed 0.5 percent, the lamp is considered stable. Luminous flux, chromaticity coordinates, correlated color temperature and color rendering index for each lamp are calculated from the spectral radiant flux measurements taken at 2 nm intervals over the range 350 to 1050 nm. The calibration of the sphere photometer-spectrometer system is traceable to the NIST USA. Lamp efficacy (lumens per watts) for each lamp model is computed based on the revised luminous flux result. Electrical measurements including voltage, current, power and power factor are measured using the YOKOGAWA WT210 digital power Meter. The total uncertainty of the light output measurements is estimated, at the 95% confidence level, not to exceed ±1.12% over the wavelength range 350-1050 nm. 2.2 Photometric and Electrical Measurement (GonioPhotometer Method) Before each measurement, the method below should be used to determine the lamp is stable or not. Step 1 Take 3 measurements of the lamp intensity at 15 minute interval (total time=30mintues.)This time period is in addition to the recommended pre-burning time. Step 2 Calculate the percent difference between the maximum measured value and the minimum measured value for the three consecutive measurements. Step 3 if the value calculated in Step 2 does not exceed 0.5 percent, the lamp is considered stable. A Everfine GOR-5000 Goniometer was used to measure the intensity (candelas) at each angle of distribution for each sample; the photometric distance is 2.436m. Ambient temperature was measured equal to the height of the sample mounted on the Goniometer equipment. Each sample was operated at input rated voltage in its designated orientation. Each sample was allowed to be stable before measurement was made. Electrical measurements including voltage, current, power and power factor were measured using the YOKOGAWA WT210 Power Analyzer. Some graphics were created with Photometric Plus software. 2.3 Deviation from standard operating procedure None
Green Venture Group Ltd. Model: MG-XVL-1200
Report No.BTR66.181.12.124.02 Page 6 of 9 IESNA LM-79 Test Report
3 – Summary of Test Result
Item Test Result Accreditation
Required Fields
ITHD 13.4% NVLAP/EPA
Lumen Output (Lumens)
4551.13 NVLAP/EPA
Luminous Efficacy (lm/w)
93.08 NVLAP/EPA
Correlated Color Temperature (CCT)
4322 NVLAP/EPA
Color Rendering Index– CRI 74.4 NVLAP/EPA
Input Power (W)
48.89 NVLAP/EPA
Optional Fields
Power Type AC DC /
Input Voltage (V)
230.0 NVLAP/EPA
Input Current (A)
0.2188 NVLAP/EPA
Power Factor 0.9716 NVLAP/EPA
x(CIE 1931) 0.3686 NVLAP/EPA
y(CIE 1931) 0.3742 NVLAP/EPA
u’ (CIE 1976) 0.2183 NVLAP/EPA
v’ (CIE 1976) 0.4987 NVLAP/EPA
Duv(CIE 1976) 0.0025 NVLAP/EPA
R9 -10 NVLAP/EPA
Beam Angle: (Degree)
115.2 NVLAP/EPA
Center beam candlepower: (cd)
1498.0 NVLAP/EPA
Zonal lumen density (0-60°): 74.8% NVLAP/EPA
Zonal lumen density (60-90°): 23.9% NVLAP/EPA
Zonal lumen density (90-120°): 1.3% NVLAP/EPA
Zonal lumen density (120-180°): 0% NVLAP/EPA
Green Venture Group Ltd. Model: MG-XVL-1200
Report No.BTR66.181.12.124.02 Page 7 of 9 IESNA LM-79 Test Report
4 – Spectral Flux Plots
Green Venture Group Ltd. Model: MG-XVL-1200
Report No.BTR66.181.12.124.02 Page 8 of 9 IESNA LM-79 Test Report
5 – EUT Photos
Green Venture Group Ltd. Model: MG-XVL-1200
Report No.BTR66.181.12.124.02 Page 9 of 9 IESNA LM-79 Test Report
6 – Luminous Intensity Distribution Test Plots (CIE Chromaticity) This page is blank and see next page.
BEST TEST SERVICE SHENZHEN CO., LTD. Page 1 Of 16
LUMINAIRE PHOTOMETRIC TEST REPORT
NAME:
DIM.:
MFR.: Green Venture Group
TYPE:
SPEC.:
SUR.:
WEIGHT:
SERIAL No.:
PROTECTION ANGLE:
Test:U:230.0V I:0.2188A P:48.89W PF:0.9716 Lamp Flux:4551.13x1 lm
0
30
60
90
120
150
-/+180
-150
-120
-90
-60
-30
UNIT:cdC0/180,120.3°
UNIT:cd
C90/270,110.1°
AVERAGE BEAM ANGLE(50%):115.2 DEG
0
300
600
900
1200
1500
LUMINOUS INTENSITY DISTRIBUTION DIAGRAM PLANAR ISOLUX DIAGRAM(UNIT:lx)
MH=1m
S(m)0
1
2
3
90
80
70
60
50
40
30
20100
C(DEG)
12001000900750600
45015075.045.015.0
DATA OF LAMP PHOTOMETRIC DATA Eff: 93.08 lm/W
MODEL
NOMINAL POWER(W)
RATED VOLTAGE(V)
NOMINAL FLUX(lm)
LAMPS INSIDE
TEST VOLTAGE(V)
Imax(cd)
LOR(%)
TOTAL FLUX(lm)
CIE CLASS
up(%)
down(%)
S/MH(C0/180)
S/MH(C90/270)
UP,DN(C0-180)
UP,DN(C180-360)
CIBSE SHR NOM
CIBSE SHR MAX
MG-XVL-1200
50
230
4551.13
1
230.0
1498
100.0
4551.1
DIRECT
1.3
98.7
1.35
1.19
0.7,50.1
0.6,48.7
1.25
1.35
C Range: 0 - 360DEGC Interval: 22.5DEG
Range: 0 - 180DEG Interval: 1.0DEG
Test Speed: MEDIUM Test System:EVERFINE GO-R5000_V2 SYSTEM V2.0.265Temperature:25.2DEG Humidity:43.1%
Test Distance:2.430m [K=1.0000]Operators:DavidTest Date:2012-07-30 Remarks:
BEST TEST SERVICE SHENZHEN CO., LTD. Page 2 Of 16
ZONAL FLUX DIAGRAMAND LUMINANCE LIMITATION CURVES
ZONAL FLUX DIAGRAM:
10 0- 10
20 10- 20
30 20- 30
40 30- 40
50 40- 50
60 50- 60
70 60- 70
80 70- 80
90 80- 90
100 90-100
110 100-110
120 110-120
130 120-130
140 130-140
150 140-150
160 150-160
170 160-170
180 170-180
C0 C45 C90 C135 C180 C225 C270 C315 zone total %lum,lamp
DEG LUMINOUS INTENSITY:cd UNIT:lm
1488 1483 1475 1472 1471 1469 1472 1481 141.9 141.9 3.12,3.12
1442 1428 1408 1406 1408 1400 1381 1425 409.8 551.7 12.1,12.1
1358 1299 1180 1288 1309 1212 1177 1285 617.2 1169 25.7,25.7
1214 1086 1064 1049 1154 1045 1057 1085 741.0 1910 42,42
1033 934.6 855.9 891.5 962.4 883.3 844.6 929.4 784.0 2694 59.2,59.2
793.4 697.2 662.8 650.5 713.1 645.2 643.8 682.7 711.0 3405 74.8,74.8
508.9 483.7 412.0 446.0 423.7 378.5 401.6 463.2 551.6 3956 86.9,86.9
216.2 268.3 318.7 234.7 166.5 237.6 307.7 249.2 350.6 4307 94.6,94.6
10.30 106.6 150.4 86.25 0.3121 87.00 141.2 91.95 186.0 4493 98.7,98.7
0.1845 16.25 26.86 12.55 0.1648 11.96 23.21 11.96 49.40 4542 99.8,99.8
0.2965 0.4827 1.643 0.4662 0.2712 0.4512 0.4358 0.4039 6.425 4549 100,100
0.3691 0.3939 0.4453 0.3996 0.4040 0.4284 0.4572 0.3764 0.3983 4549 100,100
0.4782 0.4722 0.4593 0.4967 0.5378 0.5347 0.4893 0.4803 0.3991 4550 100,100
0.6289 0.6368 0.6169 0.6568 0.6149 0.6053 0.5580 0.5598 0.4277 4550 100,100
0.7469 0.7600 0.7473 0.7717 0.5944 0.5808 0.5457 0.5523 0.4043 4551 100,100
0.8003 0.8073 0.7970 0.8060 0.6064 0.5837 0.5554 0.5734 0.3120 4551 100,100
0.7680 0.7713 0.7514 0.7720 0.6614 0.6403 0.6119 0.6287 0.1983 4551 100,100
0.7254 0.7258 0.7800 0.7260 0.7333 0.7349 0.7399 0.7236 0.0687 4551 100,100
LUMINANCE LIMITATION CURVES
GLARE CLASS ILLUMINANCE (lx)
1.15 A 2000 1000 500 <=300
1.50 B 2000 1000 500 <=300
1.85 C 2000 1000 500 <=300
2.20 D 2000 1000 500 <=300
2.55 E 2000 1000 500 <=300
a b c d e f g h
45
55
65
75
85G(DEG)
8 1000 2 3 4 5 6 8 10000 2 3 4 1
2
3
4
68
a/h
LUMINANCE (cd/(m2))
a b c d e f g h
C0/180 C90/270
LUMINANCE cd/(m2)
G(DEG) C0/180 C90/270
85 2199 5268
80 2147 3165
75 2329 2446
70 2565 2077
65 2688 2140
60 2736 2285
55 2783 2315
50 2770 2296
45 2750 2418
C Range: 0 - 360DEGC Interval: 22.5DEG
Range: 0 - 180DEG Interval: 1.0DEG
Test Speed: MEDIUM Test System:EVERFINE GO-R5000_V2 SYSTEM V2.0.265Temperature:25.2DEG Humidity:43.1%
Test Distance:2.430m [K=1.0000]Operators:DavidTest Date:2012-07-30 Remarks:
BEST TEST SERVICE SHENZHEN CO., LTD. Page 3 Of 16
CU AND LUMINAIRE BUDGETARY ESTIMATE DIAGRAM
NAME:
DIM.:
MFR.: Green Venture Group
TYPE:
SPEC.:
SUR.:
WEIGHT:
SERIAL No.:
PROTECTION ANGLE:
Test:U:230.0V I:0.2188A P:48.89W PF:0.9716 Lamp Flux:4551.13x1 lm
cc
w
fc
RCR Coefficients of Utilization(CU)RCR:Room Cavity Ratio
80%
50% 30% 10%
20%
70%
50% 30% 10%
20%
50%
50% 30% 10%
20%
30%
50% 30% 10%
20%
10%
50% 30% 10%
20%
0
0
0
0.0
1.0
2.0
3.0
4.0
5.0
6.0
7.0
8.0
9.0
10.0
1.19
1.02
.89
.78
.69
.61
.55
.50
.45
.42
.38
1.19
.98
.81
.69
.60
.52
.46
.41
.37
.33
.30
1.19
.93
.75
.62
.53
.45
.39
.35
.31
.28
.25
1.16
.00
.87
.76
.67
.60
.54
.49
.45
.41
.38
1.16
.96
.80
.68
.59
.51
.45
.41
.36
.33
.30
1.16
.92
.74
.62
.52
.45
.39
.35
.31
.28
.25
1.10
.95
.83
.73
.64
.58
.52
.47
.43
.40
.37
1.10
.92
.77
.66
.57
.50
.44
.40
.36
.33
.30
1.10
.88
.72
.60
.51
.44
.39
.34
.30
.27
.25
1.05
.91
.79
.70
.62
.56
.50
.46
.42
.39
.36
1.05
.88
.75
.64
.56
.49
.43
.39
.35
.32
.29
1.05
.86
.71
.59
.50
.44
.38
.34
.30
.27
.25
1.01
.87
.76
.67
.60
.54
.49
.44
.41
.38
.35
1.01
.85
.72
.62
.54
.48
.42
.38
.35
.31
.29
1.01
.83
.69
.58
.50
.43
.38
.33
.30
.27
.25
.99
.81
.66
.56
.47
.41
.36
.31
.28
.25
.23
AREA(m2)10 20 30 40 50 70 100 200 300 500 700 1k 2k 3k 4k 5k 7k
2
3
4
5
6
789
10
20
30
40
50LAMPS LUMINAIRE BUDGETARY DIAGRAM
45
66
H=7H=7
455
66
H=7H=7
CONDITIONS
FLUX 5000lm
FACTOR 0.70
Hdown 0.00m
Hwork 0.00m
Ework(AVE) 100lx
cc w fc
70 50 30
50 30 20
C Range: 0 - 360DEGC Interval: 22.5DEG
Range: 0 - 180DEG Interval: 1.0DEG
Test Speed: MEDIUM Test System:EVERFINE GO-R5000_V2 SYSTEM V2.0.265Temperature:25.2DEG Humidity:43.1%
Test Distance:2.430m [K=1.0000]Operators:DavidTest Date:2012-07-30 Remarks:
BEST TEST SERVICE SHENZHEN CO., LTD. Page 4 Of 16
WEC AND CCEC
NAME:
DIM.:
MFR.: Green Venture Group
TYPE:
SPEC.:
SUR.:
WEIGHT:
SERIAL No.:
PROTECTION ANGLE:
Test:U:230.0V I:0.2188A P:48.89W PF:0.9716 Lamp Flux:4551.13x1 lm
cc
w
fc
RCR Wall Exitance Coeffcients(WEC)RCR:Room Cavity Ratio
80%
50% 30% 10%
20%
70%
50% 30% 10%
20%
50%
50% 30% 10%
20%
30%
50% 30% 10%
20%
10%
50% 30% 10%
20%
0
0
0
0.0
1.0
2.0
3.0
4.0
5.0
6.0
7.0
8.0
9.0
10.0
.336
.306
.279
.256
.235
.217
.202
.188
.176
.165
.191
.168
.149
.133
.120
.109
.100
.092
.085
.079
.061
.051
.045
.039
.035
.031
.028
.026
.024
.022
.329
.300
.273
.250
.230
.213
.198
.185
.173
.162
.188
.165
.146
.131
.118
.108
.099
.091
.084
.078
.060
.051
.044
.039
.034
.031
.028
.026
.024
.022
.315
.287
.262
.241
.222
.205
.191
.178
.167
.157
.181
.160
.142
.128
.115
.105
.096
.089
.083
.077
.058
.050
.043
.038
.034
.031
.028
.025
.023
.022
.302
.276
.252
.231
.213
.198
.184
.172
.162
.152
.174
.155
.138
.124
.113
.103
.094
.087
.081
.076
.056
.048
.042
.037
.034
.030
.027
.025
.023
.022
.290
.265
.243
.223
.206
.191
.178
.167
.157
.148
.168
.150
.134
.121
.110
.101
.093
.086
.080
.074
.054
.047
.042
.037
.033
.030
.027
.025
.023
.021
cc
w
fc
RCR Ceiling Cavity Exitance Coefficients(CCEC)RCR:Room Cavity Ratio
80%
50% 30% 10%
20%
70%
50% 30% 10%
20%
50%
50% 30% 10%
20%
30%
50% 30% 10%
20%
10%
50% 30% 10%
20%
0
0
0
0.0
1.0
2.0
3.0
4.0
5.0
6.0
7.0
8.0
9.0
10.0
.200
.192
.184
.176
.168
.161
.153
.146
.140
.134
.128
.200
.166
.142
.124
.111
.101
.092
.086
.080
.075
.071
.200
.142
.106
.083
.067
.056
.049
.043
.038
.035
.032
.171
.164
.158
.151
.145
.138
.132
.126
.120
.115
.110
.171
.142
.122
.107
.096
.087
.080
.074
.069
.065
.061
.171
.122
.092
.072
.058
.049
.042
.037
.034
.031
.028
.117
.112
.108
.104
.099
.095
.091
.087
.083
.080
.077
.117
.098
.084
.074
.067
.061
.056
.052
.049
.046
.043
.117
.085
.064
.050
.041
.035
.030
.026
.024
.022
.020
.067
.065
.062
.060
.057
.055
.053
.051
.048
.046
.045
.067
.057
.049
.043
.039
.036
.033
.031
.029
.027
.025
.067
.049
.038
.030
.024
.021
.018
.016
.014
.013
.012
.021
.021
.020
.019
.018
.018
.017
.016
.016
.015
.014
.021
.018
.016
.014
.013
.012
.011
.010
.009
.009
.008
.021
.016
.012
.010
.008
.007
.006
.005
.005
.004
.004
C Range: 0 - 360DEGC Interval: 22.5DEG
Range: 0 - 180DEG Interval: 1.0DEG
Test Speed: MEDIUM Test System:EVERFINE GO-R5000_V2 SYSTEM V2.0.265Temperature:25.2DEG Humidity:43.1%
Test Distance:2.430m [K=1.0000]Operators:DavidTest Date:2012-07-30 Remarks:
BEST TEST SERVICE SHENZHEN CO., LTD. Page 5 Of 16
Uncorrected UGR Table
NAME:
DIM.:
MFR.: Green Venture Group
TYPE:
SPEC.:
SUR.:
WEIGHT:
SERIAL No.:
PROTECTION ANGLE:
Test:U:230.0V I:0.2188A P:48.89W PF:0.9716 Lamp Flux:4551.13x1 lm
ceiling/cavity
walls
working plane
Room dimensions Viewed crosswise Viewed endwise
0.7 0.7
0.5 0.5
0.2 0.2
0.7 0.7
0.3 0.3
0.2 0.2
0.5 0.5
0.5 0.5
0.2 0.2
0.5 0.5
0.3 0.3
0.2 0.2
0.3 0.3
0.3 0.3
0.2 0.2
x = 2H y = 2H
3H
4H
6H
8H
12H
4H 2H
3H
4H
6H
8H
12H
8H 4H
6H
8H
12H
12H 4H
6H
8H
16.4 15.7 17.9 17.3 16.7 16.0 18.1 17.5 18.4 17.7
18.1 17.2 19.5 18.6 18.4 17.5 19.8 18.9 20.0 19.2
18.8 18.1 20.1 19.4 19.1 18.4 20.4 19.7 20.7 20.0
19.3 19.1 20.5 20.4 19.6 19.5 20.8 20.7 21.1 21.0
19.4 19.7 20.7 20.9 19.8 20.1 21.0 21.2 21.3 21.6
19.6 20.4 20.8 21.6 19.9 20.8 21.1 21.9 21.4 22.2
16.9 16.5 18.3 17.8 17.3 16.8 18.6 18.1 18.9 18.4
18.8 18.1 20.0 19.3 19.2 18.5 20.4 19.6 20.7 20.0
19.7 19.1 20.8 20.2 20.1 19.5 21.1 20.6 21.5 20.9
20.3 20.4 21.3 21.4 20.7 20.8 21.7 21.7 22.1 22.1
20.6 21.1 21.5 22.0 21.0 21.5 21.9 22.4 22.3 22.8
20.8 21.9 21.6 22.8 21.2 22.4 22.0 23.2 22.4 23.6
20.0 19.5 20.9 20.4 20.4 20.0 21.3 20.8 21.7 21.2
20.8 21.0 21.6 21.8 21.3 21.5 22.0 22.2 22.5 22.7
21.1 21.9 21.8 22.6 21.6 22.4 22.3 23.1 22.8 23.5
21.5 23.0 22.1 23.6 22.0 23.5 22.5 24.1 23.0 24.6
20.0 19.6 20.9 20.4 20.5 20.0 21.3 20.8 21.7 21.3
21.0 21.2 21.7 21.8 21.5 21.6 22.1 22.3 22.6 22.8
21.4 22.2 22.0 22.8 21.9 22.7 22.5 23.2 23.0 23.7
Variations with the observer position at spacings:
S = 1.0H + 0.1 / - 0.2 + 0.1 / - 0.2
1.5H + 0.1 / - 0.2 + 0.2 / - 0.3
2.0H + 0.1 / - 0.2 + 0.2 / - 0.4
CIE Pub.117 Corrected 4551 lm Total Lamp Luminous Flux.(8log(F/F0) = 5.3)
C Range: 0 - 360DEGC Interval: 22.5DEG
Range: 0 - 180DEG Interval: 1.0DEG
Test Speed: MEDIUM Test System:EVERFINE GO-R5000_V2 SYSTEM V2.0.265Temperature:25.2DEG Humidity:43.1%
Test Distance:2.430m [K=1.0000]Operators:DavidTest Date:2012-07-30 Remarks:
BEST TEST SERVICE SHENZHEN CO., LTD. Page 6 Of 16
UTILIZATION FACTORS TABLE
NAME:
DIM.:
MFR.: Green Venture Group
TYPE:
SPEC.:
SUR.:
WEIGHT:
SERIAL No.:
PROTECTION ANGLE:
Test:U:230.0V I:0.2188A P:48.89W PF:0.9716 Lamp Flux:4551.13x1 lm
REFLECTANCE
Ceiling
Walls
Working plane
0.8
0.7
0.2
0.8
0.5
0.2
0.8
0.3
0.2
0.7
0.7
0.2
0.7
0.5
0.2
0.7
0.3
0.2
0.5
0.7
0.2
0.5
0.5
0.2
0.5
0.3
0.2
0
0
0
ROOM INDEX UTILIZATION FACTORS(PERCENT) k(RI) x RCR = 5
k = 0.60 56 44 37 55 44 37 54 43 37 30
0.80 66 54 46 65 53 46 63 53 46 39
1.00 74 63 55 73 62 55 71 63 54 47
1.25 81 70 63 80 69 62 77 68 61 54
1.50 86 76 68 84 75 68 81 73 67 59
2.00 93 84 77 91 83 76 87 80 75 66
2.50 97 89 82 95 87 81 91 84 79 71
3.00 100 93 87 98 91 86 94 88 84 75
4.00 105 98 93 102 96 92 98 93 89 80
5.00 107 102 97 105 100 96 100 96 92 83
ROOM INDEX UF(total) Direct
According to DIN EN 13032-2 2004 SHRNOM = 1.25Suspended
C Range: 0 - 360DEGC Interval: 22.5DEG
Range: 0 - 180DEG Interval: 1.0DEG
Test Speed: MEDIUM Test System:EVERFINE GO-R5000_V2 SYSTEM V2.0.265Temperature:25.2DEG Humidity:43.1%
Test Distance:2.430m [K=1.0000]Operators:DavidTest Date:2012-07-30 Remarks:
BEST TEST SERVICE SHENZHEN CO., LTD. Page 7 Of 16
ISOCANDELA DIAGRAM
NAME:
DIM.:
MFR.: Green Venture Group
TYPE:
SPEC.:
SUR.:
WEIGHT:
SERIAL No.:
PROTECTION ANGLE:
Test:U:230.0V I:0.2188A P:48.89W PF:0.9716 Lamp Flux:4551.13x1 lm
-90-90
-80
-80
-70
-70
-60
-60
-50
-50
-40
-40
-30
-30
-20
-20
-10
-10
0
0
10
10
20
20
30
30
40
40
50
50
60
60
70
70
80
80
90
90
HORIZONTAL(DEG)
VERTICAL(DEG)
Imax:1498(H2.5,V-1.0) (At:C=22.5,Gamma=3.0)
UNIT: cd
10% 149.820% 299.730% 449.540% 599.350% 749.160% 899.070% 104980% 119990% 1348
C Range: 0 - 360DEGC Interval: 22.5DEG
Range: 0 - 180DEG Interval: 1.0DEG
Test Speed: MEDIUM Test System:EVERFINE GO-R5000_V2 SYSTEM V2.0.265Temperature:25.2DEG Humidity:43.1%
Test Distance:2.430m [K=1.0000]Operators:DavidTest Date:2012-07-30 Remarks:
BEST TEST SERVICE SHENZHEN CO., LTD. Page 8 Of 16
AAI Figure
NAME:
DIM.:
MFR.: Green Venture Group
TYPE:
SPEC.:
SUR.:
WEIGHT:
SERIAL No.:
PROTECTION ANGLE:
Test:U:230.0V I:0.2188A P:48.89W PF:0.9716 Lamp Flux:4551.13x1 lm
1m3.281ft
287.14cm9.421ft
454.0,1497lx42.18,139.1fc
2m6.562ft
574.28cm18.84ft
113.5,374.4lx10.55,34.78fc
3m9.843ft
861.42cm28.26ft
50.45,166.4lx4.687,15.46fc
4m13.12ft
1148.56cm37.68ft
28.38,93.59lx2.636,8.695fc
5m16.4ft
1435.69cm47.1ft
18.16,59.90lx1.687,5.565fc
Height Eavg,Emax DiameterAngle:110.28deg
Flux out:3135 lm
Note:The Curves indicate the illuminated area and the average illumination when the luminaire is at different distance.
C Range: 0 - 360DEGC Interval: 22.5DEG
Range: 0 - 180DEG Interval: 1.0DEG
Test Speed: MEDIUM Test System:EVERFINE GO-R5000_V2 SYSTEM V2.0.265Temperature:25.2DEG Humidity:43.1%
Test Distance:2.430m [K=1.0000]Operators:DavidTest Date:2012-07-30 Remarks:
BEST TEST SERVICE SHENZHEN CO., LTD. Page 9 Of 16
ISOLUX DIAGRAM
NAME:
DIM.:
MFR.: Green Venture Group
TYPE:
SPEC.:
SUR.:
WEIGHT:
SERIAL No.:
PROTECTION ANGLE:
Test:U:230.0V I:0.2188A P:48.89W PF:0.9716 Lamp Flux:4551.13x1 lm
72.7' 22.15m
58.1' 17.72m
17.72m
58.1'
43.6' 13.29m
29.1' 8.86m
8.86m
29.1'
14.5' 4.43m
0.0' 0.00m
0.00m
0.0'
14.5' 4.43m
29.1' 8.86m
8.86m
29.1'
43.6' 13.29m
58.1' 17.72m
17.72m
58.1'
72.7' 22.15m
MOUNTING HEIGHT: 33'(10.0m)
3% 0.4492lx 0.04173fc
5% 0.7486lx 0.06955fc
10% 1.497lx 0.1391fc
30% 4.492lx 0.4173fc
50% 7.486lx 0.6955fc
C Range: 0 - 360DEGC Interval: 22.5DEG
Range: 0 - 180DEG Interval: 1.0DEG
Test Speed: MEDIUM Test System:EVERFINE GO-R5000_V2 SYSTEM V2.0.265Temperature:25.2DEG Humidity:43.1%
Test Distance:2.430m [K=1.0000]Operators:DavidTest Date:2012-07-30 Remarks:
BEST TEST SERVICE SHENZHEN CO., LTD. Page 10 Of 16
Average Luminance Table(CIBSE)
NAME:
DIM.:
MFR.: Green Venture Group
TYPE:
SPEC.:
SUR.:
WEIGHT:
SERIAL No.:
PROTECTION ANGLE:
Test:U:230.0V I:0.2188A P:48.89W PF:0.9716 Lamp Flux:4551.13x1 lm
Table 1. Calculation parameters for determination of CIBSE LG3:1996 Average Luminance
Parameter description for average Luminance Symbol Value Unit
Luminance in Azimuth Plane Bc refer Table 2 cd/sq.m.
Intensity at angle Gamma in given azimuth plane I from data cd/klm
Number of lamps N 1
Output of each lamp(initial lumens as specified) F 4551.13 lm
Multiplying factor K 1
Luminous area in horizontal plane used in calculations A 0.58 sq.m.
Angle to the downward vertical from light centre Gamma from data deg
Table 2. Average Luminance(cd/sq.m.) for defined C plane,Gamma angle
G
deg
C plane(deg)
55
0
2783
60 2736
65 2688
70 2565
75 2329
80 2147
85 2199
10
2620
2616
2587
2476
2360
2158
2045
20
2517
2519
2503
2414
2345
2217
2203
30
2497
2447
2440
2404
2249
2328
2787
40
2514
2397
2389
2401
2142
2481
3577
50
2488
2369
2340
2318
2148
2679
4258
60
2412
2355
2286
2162
2269
2895
4723
70
2337
2334
2215
2047
2381
3057
5021
80
2290
2291
2117
2038
2415
3116
5132
90
2261
2253
2042
2051
2412
3110
5107
100
2263
2243
2060
2013
2379
3059
5002
110
2278
2242
2108
1983
2308
2946
4770
120
2289
2237
2148
2006
2161
2749
4373
130
2298
2233
2179
2054
1999
2490
3838
140
2295
2236
2193
2087
1923
2169
3161
150
2290
2250
2195
2097
1938
1833
2413
160
2334
2298
2223
2106
1944
1614
1770
170
2456
2392
2297
2124
1889
1604
1362
180
2547
2459
2352
2136
1846
1653
1191
Table 3. Tabulation of Average and Patch Luminance(cd/sq.m.) for defined CIBSE categories
CIBSE
Category
Gamma
(deg)
Average Luminance
maximum
calculated
specified
maximum
Patch Luminance
maximum
measured
specified
maximum
Category 1
Category 2
Category 3
55 to 90
65 to 90
75 to 90
5132
5132
5132
200
200
200
---
---
---
500
500
500
No match
C Range: 0 - 360DEGC Interval: 22.5DEG
Range: 0 - 180DEG Interval: 1.0DEG
Test Speed: MEDIUM Test System:EVERFINE GO-R5000_V2 SYSTEM V2.0.265Temperature:25.2DEG Humidity:43.1%
Test Distance:2.430m [K=1.0000]Operators:DavidTest Date:2012-07-30 Remarks:
BEST TEST SERVICE SHENZHEN CO., LTD. Page 11 Of 16
Average Luminance Table(CIBSE)
NAME:
DIM.:
MFR.: Green Venture Group
TYPE:
SPEC.:
SUR.:
WEIGHT:
SERIAL No.:
PROTECTION ANGLE:
Test:U:230.0V I:0.2188A P:48.89W PF:0.9716 Lamp Flux:4551.13x1 lm
Table 1. Calculation parameters for determination of CIBSE LG3:2001 Average Luminance
Parameter description for average Luminance Symbol Value Unit
Luminance in Azimuth Plane Bc refer Table 2 cd/sq.m.
Intensity at angle Gamma in given azimuth plane I from data cd/klm
Number of lamps N 1
Output of each lamp(initial lumens as specified) F 4551.13 lm
Multiplying factor K 1
Luminous area in horizontal plane used in calculations A 0.58 sq.m.
Angle to the downward vertical from light centre Gamma from data deg
Table 2. Average Luminance(cd/sq.m.) for defined C plane,Gamma angle
G
deg
C plane(deg)
55
0
2783
60 2736
65 2688
70 2565
75 2329
80 2147
85 2199
10
2620
2616
2587
2476
2360
2158
2045
20
2517
2519
2503
2414
2345
2217
2203
30
2497
2447
2440
2404
2249
2328
2787
40
2514
2397
2389
2401
2142
2481
3577
50
2488
2369
2340
2318
2148
2679
4258
60
2412
2355
2286
2162
2269
2895
4723
70
2337
2334
2215
2047
2381
3057
5021
80
2290
2291
2117
2038
2415
3116
5132
90
2261
2253
2042
2051
2412
3110
5107
100
2263
2243
2060
2013
2379
3059
5002
110
2278
2242
2108
1983
2308
2946
4770
120
2289
2237
2148
2006
2161
2749
4373
130
2298
2233
2179
2054
1999
2490
3838
140
2295
2236
2193
2087
1923
2169
3161
150
2290
2250
2195
2097
1938
1833
2413
160
2334
2298
2223
2106
1944
1614
1770
170
2456
2392
2297
2124
1889
1604
1362
180
2547
2459
2352
2136
1846
1653
1191
Table 3. Tabulation of average luminance(cd/sq.m.) and luminance limits
Average Luminance(cd/sq.m)
Maximum limit for screen type & software category usedrange
(deg)
55 to 90
65 to 90
Maximum
measured
5132
5132
Type I,II screen
Some neg.s'ware
1000
1000
Type I,II screen
Only pos.s'ware
1500
1500
Type III screen
Some neg.s'ware
200
200
Type III screen
Only pos.s'ware
500
500
No match
C Range: 0 - 360DEGC Interval: 22.5DEG
Range: 0 - 180DEG Interval: 1.0DEG
Test Speed: MEDIUM Test System:EVERFINE GO-R5000_V2 SYSTEM V2.0.265Temperature:25.2DEG Humidity:43.1%
Test Distance:2.430m [K=1.0000]Operators:DavidTest Date:2012-07-30 Remarks:
BEST TEST SERVICE SHENZHEN CO., LTD. Page 12 Of 16
Planar Illuminance Curve
Planar Illuminance Curve
-25 -20 -15 -10 -5 0 5 10 15 20 25
Distance(m)
0
1.5
3
4.5
6
7.5
9
10.5
12
13.5
15E(lx) MH = 10 m
C0/180
C90/270
C Range: 0 - 360DEGC Interval: 22.5DEG
Range: 0 - 180DEG Interval: 1.0DEG
Test Speed: MEDIUM Test System:EVERFINE GO-R5000_V2 SYSTEM V2.0.265Temperature:25.2DEG Humidity:43.1%
Test Distance:2.430m [K=1.0000]Operators:DavidTest Date:2012-07-30 Remarks:
BEST TEST SERVICE SHENZHEN CO., LTD. Page 13 Of 16
LUMINOUS DISTRIBUTION INTENSITY DATA
NAME:
DIM.:
MFR.: Green Venture Group
TYPE:
SPEC.:
SUR.:
WEIGHT:
SERIAL No.:
PROTECTION ANGLE:
Test:U:230.0V I:0.2188A P:48.89W PF:0.9716 Lamp Flux:4551.13x1 lm
(DEG)
C(DEG) Table--1 UNIT: cd
0
0 1497
5 1497
10 1488
15 1469
20 1442
25 1405
30 1358
35 1299
40 1214
45 1128
50 1033
55 926
60 793
65 659
70 509
75 350
80 216
85 111
90 10.3
95 0.14
100 0.18
105 0.24
110 0.30
115 0.34
120 0.37
125 0.42
130 0.48
135 0.55
140 0.63
145 0.69
150 0.75
155 0.78
160 0.80
165 0.80
170 0.77
175 0.77
180 0.73
23
1497
1497
1487
1467
1438
1399
1351
1291
1214
1107
946
832
729
615
475
355
231
125
76.4
11.3
0.67
0.39
0.31
0.34
0.37
0.42
0.48
0.56
0.63
0.70
0.75
0.78
0.80
0.80
0.77
0.78
0.73
45
1497
1495
1483
1461
1428
1385
1299
1157
1086
1016
935
843
697
589
484
325
268
211
107
60.1
16.2
3.11
0.48
0.43
0.39
0.41
0.47
0.55
0.64
0.71
0.76
0.79
0.81
0.80
0.77
0.77
0.73
68
1497
1494
1479
1453
1417
1309
1189
1137
1075
1004
868
789
686
573
417
362
313
259
144
100
24.4
18.5
0.47
0.45
0.43
0.42
0.47
0.55
0.64
0.72
0.77
0.80
0.82
0.81
0.78
0.78
0.73
90
1497
1492
1475
1447
1408
1266
1180
1127
1064
992
856
770
663
525
412
367
319
266
150
106
26.9
21.6
1.64
0.46
0.45
0.43
0.46
0.53
0.62
0.69
0.75
0.78
0.80
0.79
0.75
0.75
0.78
113
1497
1491
1474
1445
1406
1309
1176
1120
1056
984
852
767
666
558
400
346
296
242
131
66.6
22.6
12.5
0.47
0.46
0.43
0.43
0.48
0.56
0.64
0.71
0.76
0.79
0.80
0.80
0.76
0.79
0.72
135
1497
1490
1472
1444
1406
1359
1288
1137
1049
974
892
794
650
545
446
290
235
177
86.3
36.8
12.5
0.52
0.47
0.42
0.40
0.43
0.50
0.58
0.66
0.72
0.77
0.79
0.81
0.80
0.77
0.77
0.73
158
1497
1489
1472
1445
1409
1363
1308
1240
1157
1061
922
769
660
542
428
300
177
92.4
39.1
5.25
0.48
0.30
0.33
0.36
0.39
0.44
0.51
0.58
0.66
0.72
0.76
0.79
0.81
0.80
0.76
0.77
0.73
180
1497
1489
1471
1444
1408
1363
1309
1243
1154
1063
962
847
713
576
424
277
166
60.2
0.31
0.13
0.16
0.21
0.27
0.33
0.40
0.48
0.54
0.59
0.61
0.62
0.59
0.58
0.61
0.63
0.66
0.71
0.73
203
1497
1489
1470
1442
1405
1358
1302
1239
1141
988
865
765
659
539
406
287
153
100
43.8
6.59
0.53
0.33
0.30
0.35
0.42
0.49
0.55
0.59
0.62
0.62
0.60
0.58
0.60
0.62
0.65
0.71
0.73
225
1497
1488
1469
1439
1400
1344
1212
1111
1045
968
883
737
645
530
379
290
238
180
87.0
37.0
12.0
0.51
0.45
0.42
0.43
0.48
0.53
0.58
0.61
0.61
0.58
0.56
0.58
0.60
0.64
0.70
0.73
248
1497
1489
1469
1439
1392
1254
1170
1114
1049
973
833
752
635
482
386
340
290
232
126
55.2
20.8
9.65
0.45
0.44
0.45
0.47
0.51
0.55
0.58
0.59
0.57
0.56
0.58
0.60
0.63
0.70
0.73
270
1497
1490
1472
1442
1381
1240
1177
1122
1057
968
845
734
644
476
402
357
308
250
141
62.5
23.2
15.5
0.44
0.46
0.46
0.46
0.49
0.52
0.56
0.56
0.55
0.53
0.56
0.58
0.61
0.71
0.74
293
1497
1492
1476
1449
1410
1282
1188
1134
1070
997
856
776
673
525
399
348
298
243
130
56.2
20.4
9.68
0.42
0.42
0.42
0.44
0.48
0.52
0.56
0.56
0.54
0.54
0.56
0.59
0.62
0.66
0.77
315
1497
1495
1481
1458
1425
1381
1285
1159
1085
1011
929
832
683
571
463
308
249
190
91.9
37.9
12.0
0.47
0.40
0.37
0.38
0.43
0.48
0.52
0.56
0.57
0.55
0.54
0.57
0.60
0.63
0.68
0.72
338
1497
1496
1486
1466
1437
1397
1349
1289
1215
1119
978
831
721
603
479
346
220
107
52.0
6.22
0.47
0.25
0.25
0.30
0.37
0.43
0.49
0.54
0.57
0.58
0.57
0.56
0.58
0.61
0.65
0.71
0.73
C Range: 0 - 360DEGC Interval: 22.5DEG
Range: 0 - 180DEG Interval: 1.0DEG
Test Speed: MEDIUM Test System:EVERFINE GO-R5000_V2 SYSTEM V2.0.265Temperature:25.2DEG Humidity:43.1%
Test Distance:2.430m [K=1.0000]Operators:DavidTest Date:2012-07-30 Remarks:
0 1020
30
40
50
60
70
80
90270
280
290
300
310
320
330
340350
A
B
A
B
150
300
450
600
750
900
1050
1200
1350
1500
I(cd)