MEASURE ENSURE TOMORROW REGAL Series RH20 ……is often used for small and medium size pipes. The...
Transcript of MEASURE ENSURE TOMORROW REGAL Series RH20 ……is often used for small and medium size pipes. The...
• Economicaltoolforbi-directionalflowmeasurement• Non-intrusive,clamp-oninstallation,easyandfast• Signalqualitytrackingandself-adaptationforrobustperformance
• Compactdesign,allowingthemainunittobeheldandoperatedwithonehand
• Suitableforpureliquidsandliquidswithsomeparticles.Nodependencyonconductivity
ApplicationsTheRH20handheldflowmeterisoneofthemostpowerfulyetportableflowmetersonthemarket.Theutilizationofourproprietaryultrasonicsignalprocessing,transit-timedetection,signalqualitytracking,aswellasself-adaptationtechnologies,allowstheflowmetertomeasureliquidflowratefromoutsideofapipereliablyandaccurately.Examplesofapplicationsinclude:
• Water,includinghotwater,chilledwater,citywater,andseawater.
• Sewageanddrainagewaterwithsmallparticlequantity• Oil,includingcrudeoil,lubricatingoil,dieseloil,fueloil,etc.• Chemicals,includingalcohol,acidsandmore.• Solvents• Beverageandfoodprocessors• HVAChotandcoolwater,water/glycolsolutions• Waterandwastetreatment• Powerplants(nuclear,thermal&hydropower)heatenergyboilerfeedwater
• Energyconsumptionsupervisionandwaterconservationmanagement
• Suitableforallcommonlyusedpipematerials• Widepipesizerange• Rechargeablebatteryfor8hoursofoperation• Self-explanatoryuserinterface,easytooperate• Built-indataloggerandflowtotalizers• StufManagerTMPCsoftwarefordatadownloadandreal-timedataacquisition
• USBinterfaceforPClink
MEASURE TODAY.ENSURETOMORROW
REGAL Series RH20HandheldUltrasonicFlowmeter
Features and Benefits
• Metallurgyandminingapplications(e.g.,acidrecovery)• Marineoperationandmaintenance• Pulpandpaper• Pipelineleakdetection,inspection,trackingandcollection• Energymeasurementandbalancing• Waterdistributionnetworkmonitoring
AdvancedClamp-onTransit-timeTechnologyforAccurateFlowMeasurement
DS-RH
20-170811-Rev.5
Spire Metering Technology LLC,249CedarHillStreet,Marlborough,MA01752,USATel +1978263-7100/888738-0188(toll-free)Fax [email protected]
MEASURE TODAY. ENSURE TOMORROW2
REGAL Series RH20 Handheld Ultrasonic Flowmeter
AmemberoftheRegalSeries,theRH20HandheldUltrasonicFlowmeteristhefirstmemberofthe3rdgenerationultrasonicflowmetersfromSpireMetering.Comparedwithitspredecessors,the3rdgenerationflowmetersofferbetterperformanceandaricherfeatureset,allatalowerprice.
TheRH20handheldflowmeteriscarefullydesignedtobesocompactthatyouareabletouseonehandtoholdandoperatethemeter.Theuserinterfaceisself-explanatoryandsimpletofollow.Theuniqueclamp-onfixturedesignmakestheinstallationhasslefreeandnospecialskillsortoolsarerequired.
SpireMeteringofferstheStufManagerTM PC softwarefordataloggingdownloads,aswellasexploringthefullpotentialoftheRH20f lowmeter.
RH20isthebestchoiceforflowsurvey,meterverification,pumpchecking,HVACbalancing,facilitymanagementandotherdemandingflowmonitoringapplications.
MEASURE TODAY. ENSURE TOMORROW 3
REGAL Series RH20Handheld Ultrasonic Flowmeter
transit-timedifference,thegeometryofthepipeandthefluiddynamicsformula.
ThesensorsarecommonlymountedwiththeZ-methodorV-method.WiththeZ-method,thetwosensorsareinstalledonoppositesidesofthepipe.Thismethodoffersashortersoundpath,thus,bettersignalstrength.Itisoftenusedforlargesizepipeswheresignalstrengthismoreimportant.WiththeV-method,thetwosensorsareinstalledonthesamesideofapipe.Thesoundpathisdoubled,thus,themeasurementaccuracyisbetter.Thismethodisoftenusedforsmallandmediumsizepipes.
TheRegalSeriesflowmetersarebasedonthetransit-timemeasurementprinciple,wherethesystemutilizesapairofsensors(AandBinfigurebelow)thatfunctionasbothanultrasonictransmitterandreceiver.Thesensorsareinstalledonthepipewall,clampedontheoutsideofthepipe.Theflowmeteroperatesbyalternatelytransmittingandreceivingacodedburstofsoundenergybetweenthetwosensorsandmeasuringthetransittimeittakesforsoundtotravelbetweenthetwosensors.Thedifferenceinthetransittimeisdirectlyrelatedtothevelocityoftheliquidinthepipe.Theflowrateisthencalculatedbasedonthe
Measurement Principle
Flow
UpstreamTransducer
ClampFixture
DownstreamTransducer
L
Flow
UpstreamTransducer
Spacing
DownstreamTransducer
ClampFixture
SoundPath
MEASURE TODAY. ENSURE TOMORROW4
REGAL Series RH20 Handheld Ultrasonic Flowmeter
Thereareseveraltypesoftransducersyoumaychooseforyourapplication.HSandHMtransducershavemountingrails,andareeasytoinstall(figuresaandb).Youmayneedaclampingstraptotiethemountingrailtothepipeifthemagnetontheraildoesnotworkwiththepipematerial.Allothertypesoftransducersdonothaveamountingrailanditisnecessarytoclampthemontothepipeusingthesuppliedclampingstrap(c).
Typical Transducer Installation
Thesiteofthetransducerinstallationisveryimportant.Herearesomerecommendationsforselectingthecorrectsite:• Inordertoachievegoodaccuracy,itisrecommendedtohave15Dstraight-piperun:upstream10Danddownstream5D,whereDispipediameter.
• Ifthereisavalveupstreamandthevalveisnotfullyopen,itcouldgenerateadisturbancein theflow.Alongerupstreamstraightpiperunisrecommended.• Ifthereisapumpupstream,werecommendtohave25Dstraightpiperun.• Ifpipeisvertical,makesuretheflowisgoingupward,notdownward.Downwardflowcouldhaveairgapsiftheflowisinafreefall.
• Ifpipeishorizontal,makesurethepipeisfullandensurethetransducerisinstalledonthesideofthepipe,notonthetoporbottomofthepipe.
a
b
c
InstallationSiteExamples
OK
Bad
Bad
10D 5D
10D 5D
10D 5D
10D
5D
10D5D
OK
OK
OK
MEASURE TODAY. ENSURE TOMORROW 5
REGAL Series RH20Handheld Ultrasonic Flowmeter
Specifications: Flow Transmitter (Main Unit)
Flow Velocity ±10m/s(±32ft/s),bi-directional.Accuracy ±1%ofreading±0.01m/s(±0.03ft/s)invelocity.
Repeatability 0.5%Response Time 0.5s.Configurablebetween0.5sand99s.
Display / Keypad
LCDwithbacklight,4x16letters,4x4tactile-feedbackmembranekeypad.Displaysinstantaneousflowrate,flowtotal(positive,negativeandnet),velocity,time.
Units English(U.S.)ormetric.Physical Quantity Volumetricflowrate,totalflow,velocity.
Totalizers Positivetotalizer,negativetotalizer,nettotalizer,manualtotalizer.
Output OpticallyisolatedOpenCollectorTransistoroutput(OCT)forfrequencyandpulse.
RecordingAutomaticallyrecordsthedailytotalofthelast128days,themonthlytotalofthelast64monthsandtheyearlytotalofthelast5years.
Data Logger Built-indataloggercanstoreover2,000linesofdata.Communication Interface USB
Software StufManagerPCsoftwarefordataloggerdownloadandreal-timedataacquisition.
Pipe Size Range 1”-120”(DN25mm-DN3,000mm),dependingontransducer.Pipe Material Allmetals,mostplastics,somelinedpipes.
Liquid Type Mostliquidswithfewerthan1%suspendedparticles<75uminafullpipe.
Liquid Temperature 32°F~302°F(0~150°C),DependsonifL1isalsohightemp.Enclosure HandheldUnit CarryingCase
Protection IP54Hardplasticcase.Suitablefornormalandharshenvironments
Dimensions 8”x4”x1.5”(205mmx103mmx37mm)
20”x18”x6”(508mmx457mmx152mm)
Weight 1.2lbs(538g)withbatteries 16lbs(8kg)(entirepackage)
Power source3AAANi-Hbuilt-inbatteries.Whenfullyrecharged,itwilllastover8hoursofoperation.USBpowercharger.
MEASURE TODAY. ENSURE TOMORROW6
REGAL Series RH20 Handheld Ultrasonic Flowmeter
How To Order
RH20 - -
Thickness GaugeYes YNo N
Transducer*Forpipesize1”-4”(DN25-100) 1Forpipesize2”-28”(DN50-700) 2Forpipesize1”-28”(DN25-700) 3
Example: RH20-3-N. Standardhandheldultrasonicflowmeterpackageforpipesizesfrom 1”(DN25)to28”(DN700)withoutthicknessgauge.
Features include:• Mainunit(handset)• HStransducerwithmountingrail(magnetic)• HMtransducerwithmountingrail(magnetic)• Transducercable–15ft(5m)• Clampingstretcher• Couplant• Batterycharger• USB cable• Carryingcase• 3-pointcalibrationcertificate• StufManagerTMPCSoftware• User’smanual
Value Package
* For additional pipe sizes see page 7.
MEASURE TODAY. ENSURE TOMORROW 7
REGAL Series RH20Handheld Ultrasonic Flowmeter
Type:CablePN#:TH-CBLEX
Extensioncable,15’(5m),forhandheldflowmetertransducer
Type:ThicknessGaugePN#:UT850
Thicknessgaugeformeasuringpipewallthicknessonplasticandmetalpipes,rangingfrompipesizeDN25-3000mm(1”-120”)
Type:BatteryPackPN#:HA-BP
Batterypack
Type:BatteryChargerPN#:HA-BC
Batterychargerforhandheldflowmeter
Type:CarryingCasePN#:HA-CC
Aluminumcarryingcase
Type:CouplantPN#:TH-CPLT-G
Lithiumgreaseacousticcouplant
Type:ClampPN#:TH-CLP2
Clampingstrapsfortransducermounting
RH20 - -
Optional And Replacement PartsModel Picture Description
Type:HSPN#:THC-HS
Smallsizetransducer(mountingrackwithmagnetic)Dim7.9”x1”x1”(200x25x25mm3)Forpipesize:1”-4”(DN25-100mm)Temperature:32˚F-302˚F(0-150°C)
Type:HMPN#:THC-HM
Mediumsizetransducer(mountingrackwithmagnetic)
Dim 11”x1.6”x1.6”(280x40x40mm3)foreachPipesize:2”-28”(DN50-700mm)Temperature:32˚F-302˚F(0-150°C)
Type:L1PN#:THC-L1
LargesizetransducerDim3.1”x2.7”x2.2”(80x70x55mm3)Pipesize:12”-120”(DN300-3000mm)Temperature:32˚F-176˚F(0˚C-80˚C)
Type:CablePN#:TH-CBL
Standard 15’(5m)cableforhandheldflowmetertransducer
MEASURE TODAY. ENSURE TOMORROW8
REGAL Series RH20 Handheld Ultrasonic Flowmeter
PC SoftwareWithStufManagerTMsoftware,youcanuploaddatafromthedataloggerinsidetheflowmeterdirectlytoyourcomputer.Youcanalsoformattheuploadedrawdataintostandardformatswithasimpleclickofthemouse.YoumaythensavethedatatoyourcomputerharddriveanduseExcelorotherspreadsheetsoftwaretomanipulatethedataatalaterpoint.
StufManagerTMsoftwareallowsyoutoacquiretheflowmeterdatainreal-timeanddisplaythedataonagraphicalinterface.Youcansavethereal-timedatatoyourcomputereasily.
StufManagerTMisaWindows-basedPCsoftwareaimedtofacilitatetheuseofandtoexplorethefullpotentialoftheRH20handheldflowmeter.
StufManagerTMsoftwaremakesitveryeasytoconnectaRH20devicetoaPCthroughUSBconnection.ThesoftwareautomaticallydetectsthevirtueCOMportusedbytheUSBportandtalkstotheflowmeterwithminimumhumaninteraction.Fortheseuserswithlimitedtechnicalexpertise,thissoftwareisessentialasitseaseofusesavesbothtimeandmoney.
SpireMeteringisagloballeaderinflowandenergymanagementsolutions.Throughcontinuousinnovation,wetransformcomplexultrasonictechnologyintoaffordable,reliablesolutionsforaccurateflowandenergymeasurement.SpireMeteringofferswater,heat,electricityandgasmetersaswellasAMR/AMIandbillingsolutions.Letushelpyouwithyourapplicationtoday.
About Spire Metering Technology