MDF DDF Product document
-
Upload
rajakalyan -
Category
Documents
-
view
181 -
download
16
description
Transcript of MDF DDF Product document
www.sunseagroup.com
2008 2009 Catalog
MDF&DDF
SUNSEA founded in 1994, is a professional enterprise which specializes in
research and development (R&D), manufacturing, marketing and service of com-
munications equipment. Headquartered in Shenzhen, SUNSEA employs appro-
ximately 1,000 staffs, more than 15million USD fixed assets and 50million USD
Gross assets. In 2003 , SUNSEA established the joint venture with IDG
Technology Investment Fund USA .
We provide a full range of physical connectivity products and solutions,
including audio Main Distribution Frame (MDF), Digital Distribution Frame (DDF),
Optical Distribution Frame (ODF), Structured Wiring System, etc. We are also
researching outdoor solutions, p roviding s helters, outdoor c abinets,communication
base station accessories, etc. SUNSEA has become one of the leading suppliers
in splicing & distributing wiring system. SUNSEA holds more than 60 patents.
We set up the joint laboratory with government which focus on researching of
connectivity application.
With years professional te chnology and en gineering ex periences,more than 10
SUNSEA domestic market occupation rate ranks first. We have 28 sales and
engineering service offices in domestic China and set up two oversea branches:
Russia office and North-America office. Our customers around the world include
communications providers, wireless service providers and broadcast television
operators. We have good cooperation with well-known telecom equipment manu-
facturers, such as Ericsson Alcatel-lucent , Nokia Siemens Networks(NSN),
Huawei,ZTE, etc. SUNSEA products are applied in more than 20 countries, such
as Russia, America, Korea, Vietnam, Pakistan, India, Nepal, Nigeria, Yemen, etc.
At present, SUNSEA owns five professional manufacture facilities covering
220000m , including copper connectivity productsmanufacturing plant, optic passive
components manufacturing division, metal sheet product manufacturing division,
RF product manufacturing subsidiary , outdoor shelter plant - joint venture with
KITAMURA (Japan) . Besides, SUNSEA Guanlan manufacture base occupying2
41000 m has been put into used in 2006 .
SUNSEA began to implement the ISO9000 quality control system in 1995.
At present, We obtained ISO9001:2000 quality system certificate issued by BSI
and TLC. In 2005, we passed the certification of ISO14001 Environmental Mana-
gement System.
2Guanlan Manufacture Base( 41000 m )
CONTENTCONTENT
JPX294 MDF Products
JPX294-A Double-sided Main Distribution Frame
JPX294-B Single-sided Main Distribution Frame
JPX294-DA MDF Cabinet
JPX294-E Wall-mounted Main Distribution Frame
JPX294 Accessories
4
7
8
9
10
JPX38-2 MDF Products
JPX38-2-B Single-sided Main Distribution Frame
JPX38-2 Accessories
21
24
Copper Distribution Products For Subscriber
XF5-85-B Cross Connection Box
JPX399-H Distribution Box
XF5-85-A Cross Connection Box
XF0-49-A Distribution Box
29
31
32
34
JPX38 MDF Products
JPX38-A Double-sided Main Distribution Frame
JPX38 Accessories
25
28
MDF>>
JPX399 MDF Products
JPX399-A Double-sided Main Distribution Frame
JPX399-B Single-sided Main Distribution Frame
JPX399-D MDF Cabinet
JPX399-E Wall-mounted Main Distribution Frame
JPX399-F Wall-mounted MDF Box
M19C Unit
JPX399 Accessories
12
15
16
17
18
19
20
ADSL Broadband Distribution Solutions
ST0-210SC Series Broadband Distribution Modules
ST0-210SC Series Splitters
38
40
Accessories 41
High-density Distribution Module 36
Overview
Besides innovative tech nology, conformity with standard and high reliablity-ie durability and operational safety and
easily-is the basis for the widely use in the telecommunication networks for years of the operator and the user of the
dedicated networks of the SUNSEA Main Distribution Frames(MDF) series products. The scope of application is ranges
from center equipment room to the cable distribution for the subscriber.
Features
Modular design
Perfect cable routing management
Clear line identification
4-level audible & visible alarm system
Open-circuit protection technology
Reliable protection against over-voltage & over-current
Compliant with YD/T694-2004
A.Equipment Room
B.Industrial building
C.Business building
D.Apartment
1.Main Distribution Frame
2.Cross connection cabinet
3.Cross connection box
4.Junction box
5.Outdoor distribution box
6.Indoor distribution box
Application
D5
D
6
6
D
8
8
B
D
6
6
D
3
A
12
2
8
8
7
C
7
4
Main Distribution Frame
SUNSEA TELECOMMUNICATIONS CO.,LTD.
MDF Technical Parameters
Main Distribution Frame
Ambient condition
Temperature: 0 +55
RH <85%(+30 )
Atmospheric pressure 70 106KPa
Terminal Block
Insulation resistance 1000M
Dielectric strength no spark when tested under 1000VAC (45Hz 60Hz), for 1 minute
Contact resistance between 7m ; increment of the environment test and 200 times insertion 3m
Contact resistance between termination 3m ; increment of environment test 2m
D 25N
Fire-retardant performance of plastic part compliant with Ul94 V0
contact points
points
isconnect tensile
Conductor diameter: 0.32 0.7mm, the maximum outer diameter 1.4 mm
Protector
YD/T694-2004 Over-voltage and over-current part is compliant with standard
Insulation resistance 1000M
Contact resistance between two tags 7m ; increment of environment test and 200 times insertion 3m
Loop resistance at normal temperature 14 ; different resistance 2 (between line a and line b )
Non-operation current 90mA (40 )1 hour
Current restriction characteristic
Recovery time of over-current 60s
Non-operation voltage -185V
Impulse recovery time 150ms
SUNSEA TELECOMMUNICATIONS CO.,LTD.
Mode Current (A) Fail-save time(s) Remarks
1 0.35 <4.0
2 0.5 <2.0Circuit isolated or current limited to 150mA
3 1 <0.4
4 3 <0.1Circuit isolated or current limited to 500mA
Patents
The Main Distribution Frame (MDF) of SUNSEA has
independent intellectual property rights, and have
researched and developed after analyzing customers'
various practical needs.
This kind of products had applied 21 patents, 16 of
them was acquired accreditation and certificates from
State Intellectual Property Office.
Product certification
Our MDF products have awarded certificate by TLC
Certifications Center (TLC), which is the authority in
telecom field. TLC inspects our products and super-
vises our manufacture process annually.
Main Distribution Frame
SUNSEA TELECOMMUNICATIONS CO.,LTD.
JPX294 -A
FA8-210-2
FA9-210
ST0-210-08X16
Brief
Having excellent transmission performance in networks, JPX294 MDF products provide a high-density, large capacity
& easy-to-operate solutions for various exchanges, meet the various business needs.
Features
Double-sided frame has enough space for operation
Perfect cable routing management system
Aluminum extrusion frame, assembled free of drilling, easy for combination and extension
Modularized design, simple installation, manifold specification & capacity
With large-capacity and high-density as small volume block
Reliable protection against over-voltage & over-current
4-level audible & visible alarm system
Remarks:The ordering information for product above refer to Page 6
ZG-B2
LG-B2
JPX294-A Double-sided Main Distribution Frame
SUNSEA TELECOMMUNICATIONS CO.,LTD.
High-densityDistribution Solutions
ST0-210-08X16
FA9-210
FA8-210-2
FA8-210-2 Protective block
Copper-alloy terminal tags have perfect conductivity and
elasticity, and with envelope structure
Excellent wire lead system
Perfect alarm system and reliable earthling system
Clear line identification
Flexible installation
ST0-210-08 16 Test block
Copper-alloy terminal tags have perfect conductivity and
elasticity, and with envelope structure
Excellent wire lead system
Clear line identification
Flexible installation
FA9-210 Protector
Open-circuit protection
Perfect protection with rapid action
Under certain conditions, the Protector can rework by
restoration switch after fail-protection
Reliable protection against over-voltage & over-current
Remarks:The ordering information for product above refer to Page 6
Features
JPX294-A Double-sided Main Distribution Frame
SUNSEA TELECOMMUNICATIONS CO.,LTD.
High-densityDistribution Solutions
Ordering information
External line Internal line Specifications
Code Model Maximumcapacity(pairs)
ColumnProtective
block/column
Maximumcapacity(pairs)
RowTestblock/raw
H W D(mm)
Weight(Kg)
Remarks
SS4.102.125 JPX294-A1-2 6 1200 2 6 1024 4 21800 500 860
without guardrail49.3
SS4.102.126 JPX294-A1-2 8 1600 2 8 1536 6 21800 500 860
without guardrail53.3
SS4.102.127 JPX294-A1-2 10 2000 2 10 1792 7 22200 500 860
without guardrail58.3
SS4.102.128 JPX294-A1-2 12 2400 2 12 2304 9 22605 500 860
without guardrail62.6
AdoptingFA8-210-2Protective block,
ST0-210-08 16
Test block
Remarks Increasing a row of MDF leads to another one test block per row, width increasing 250mm accordingly
Guardrail is optional when column over 4
SpecificationsName Code Model
H W D(mm)
Capacity(pairs)
Weight(g)
Remarks
Protective block SS3.691.063 FA8-210-2 182.6 136 96.5 100 1205.8
SS3.691.313 ST0-210-08 16A 106 200 93 128 1161.5 Suit for 2# aluminum extrusion
SS3.691.314 ST0-210-08 16B 106 200 93 128 1161.5 Suit for 1# aluminum extrusionTest block
SS3.691.215 HP-D8-128Y 127.5 252 85 128 Suit for JPX294-DA
SS4.811.111 FA9-210-7 11.7 11.5 64.5 1 7.5 PPTCR, SAProtector
SS4.811.112 FA9-210-8 11.7 11.5 64.5 1 7.5 PPTCR, GDT
SUNSEA TELECOMMUNICATIONS CO.,LTD.
High-densityDistribution Solutions
JPX294-B
Features
Single-sided frame can be installing on wall, or back-to-back
Perfect cable routing management system
Aluminum Extrusion frame, assembled free of drilling,
easy for combination and extension
Modularized frame structure, simple installation, manifold
specification & capacity
Large-capacity and high-density as small volume block
Reliable protection against over-voltage & over-current
4-level audible & visible alarm system
External line Internal line Specifications
Code Model Maximumcapacity(pairs)
ColumnProtective
block
Maximumcapacity(pairs)
ColumnTest
blockH W D(mm)
Weight(Kg)
Remarks
SS4.102.163 JPX294-B1-1 6 600 1 6 512 1 4 1800 500 577 26.2
SS4.102.164 JPX294-B1-1 8 800 1 8 768 1 6 1800 500 577 28.4
SS4.102.165 JPX294-B1-1 10 1000 1 10 896 1 7 2200 500 577 32.2
SS4.102.166 JPX294-B1-1 12 1200 1 12 1152 1 9 2600 500 577 40.3
Adopting FA8-210-2Protective block &
ST0-210-08 16
Test block
Remarks The ordering information of Protective block Test block and Protector refer to P6
Ordering information
SUNSEA TELECOMMUNICATIONS CO.,LTD.
JPX294-B Single-sided Main Distribution Frame
High-densityDistribution Solutions
JPX294-DAFeatures
Steel cabinet, installed flexibly, and suitable for small or medium-sized exchange
Perfect cable routing management system
Modularized frame structure, simple installation, manifold specification & capacity
Reliable protection against over-voltage & over-current
3-level audible & visible alarm system
Excellent sealed performance
External line Internal line
Code Model Maximumcapacity(pairs)
ColumnProtective
block/column
Maximumcapacity(pairs)
ColumnTest
block/column
Specifications
H W D(mm)Weight
(Kg)Remarks
SS4.100.110 JPX294-DA1 2400 2 12 2048 2 8 2600 600 600 133
SS4.100.191 JPX294-DA2 1600 2 8 1536 2 6 2000 600 600 102.3
SS4.100.190 JPX294-DA3 2000 2 10 1792 2 7 2200 600 600 112.5
Adopting FA8-210Protective block & HP-D8-128 Testblock.
Remarks The ordering information of Protective block Test block and Protector refer to P6
Ordering information
SUNSEA TELECOMMUNICATIONS CO.,LTD.
JPX294-DA MDF Cabinet
High-densityDistribution Solutions
JPX294-E
Single-sided frame is installed on wall, and suit for exchange with limit space
Perfect cable routing management system
Aluminum extrusion frame, assembled free of drilling, easy for combination and extension
Modularized frame structure, simple installation, manifold specification & capacity
Large-capacity and high-density as small volume block
Reliable protection against over-voltage & over-current
4-level audible & visible alarm system
Features
External line Internal line Specifications
Code Model Maximumcapacity(pairs)
ColumnProtective
block/column
Maximumcapacity(pairs)
ColumnTest
block/ column
H W D(mm)
Weight(Kg)
Remarks
SS4.102.122 JPX294-E1-2 5 1000 2 5 1024 2 4 1350 1000 537 45.6
SS4.102.123 JPX294-E1-2 6 1200 2 6 1024 2 4 1800 1000 537 53.2
SS4.102.124 JPX294-E1-2 8 1600 2 8 1536 2 6 1800 1000 537 57.5
AdoptingFA8-210-2Protective block &
ST0-210-08 16
Test block
Ordering information
Remarks The ordering information of Protective block Test block and Protector refer to P6
SUNSEA TELECOMMUNICATIONS CO.,LTD.
JPX294-E Wall-mounted Main Distribution Frame
High-densityDistribution Solutions
HC-210A-11 HC-210A-21
Remarks:The ordering information for product above refer to Page 11
ZG-B2
ZT-210Y
LG-B2 XD-B1
HD-210ACZ--A1
SUNSEA TELECOMMUNICATIONS CO.,LTD.
JPX294 Accessories
High-densityDistribution Solutions
Ordering information
SUNSEA TELECOMMUNICATIONS CO.,LTD.
JPX294 Accessories
High-densityDistribution Solutions
SpecificationsName Code Model
H W D(mm)
Capacity(pairs )
Weight(g)
Remarks
Column alarm SS2.900.103 LG-B2 50 248 174 726.5 Suit for all style of MDF.
SS2.900.003 ZG-B2 100 150 40 594.8 Suit for all style of MDF.General alarm
SS2.900.005 ZG-B2A 100 150 40 59With output jack for intelligent m onitoring.Suit for all style of MDF.
Insertion tool SS4.430.010 XD-B1 20 33 169 70.1Suit for the wire which diameter is 32-0.60mm,lifetimes>20000.Suit for all style of MDF.
Test cord socket SS3.665.000 CZ-A1 60 150 40.5 627Aviation clamps, as test accessory for Protective block and Test block.Suit for all style of MDF.
Test cord forProtective block
SS3.695.065 ZC-210-1Y L=3m 1 97.5Crocodile clampsSuit for FA8-210 Protective block
Online test cord SS3.695.219 HC-210A-11 L=3m 121.6 Suit for ST0-210-08 16 Test block
Disconnectiontest cord for Test
blockSS3.695.226 HC-210A-21 L=3m 121.6 Suit for ST0-210-08 16 Test block
SS3.645.273 HD-210A 3 49 9.5 1 0.5 Suit for ST0-210-08 16 Test block
SS3.645.231 HD-C1 7.5 47.5 8.5 1 0.5 Suit for HP-D8-218 Test blockDisconnection
plug
SS3.645.062 ZT-210Y 11.7 11.5 64.5 1 5 Suit for FA8-210 Protective block
Earthing plug SS3.645.301 JD-210 11.7 11.5 64.5 1 2 Suit for FA8-210 Protective block
U,9,1.55,R RZT-A1 H=1.55 m 5000
U,9,2.0,R RZT-A2 H=2.0 m 12000A-shaped ladder
U,9,2.4,R RZT-A3 H=2.4 m 14000
Aluminum alloy, suit for the frame whose height is below 2.4m.
U,9,1.3 ,P HT-B1 H=1.3 m 1500Ladder platform
U,9,0.6,P HT-B2 H=0.6 m 600
Steel tube
SS4.422.000 DG-A1 L=2.0 m 3000 1piece/set, with a guide rail jack.Guide rail
SS4.422.001 DG-A11 L=2.0 m 3000Suit for frame combining; 2 pieces/set, with a guiderail jack.
FA9-399
FA8-399
ST0-399
JPX399-A
Brief
Benefiting from high-interchange and easy-operation, the JPX399 distribution product is designed for the rough
environment of subscriber, and suit for various occasions.
Features
Double-sided frame with enough space for operation
Perfect cable routing management system
Aluminum extrusion frame, assembled free of drilling, easy for combination and extension
Modularized structure, simple installation, manifold specification & capacity
Different function blocks can be interchanged easily by the same installation
Reliable protection against over-voltage & over-current
3-level audible & visible alarm system
Remarks:The ordering information for product above refer to Page 14
LG-B2
ZG-B2
Distributing Solutions For System Line & Surbscriber
SUNSEA TELECOMMUNICATIONS CO.,LTD.
JPX399 Double-sided Main Distribution Frame
FA8-399
ST0-399
JPX399
FA9-399
JPX399 Module
Offer 8 /10-pair series module
Flexible structure, easy to be interchanged
The connection Protective block can rework
without Protector
FA8-399 Protective block
8/10 pairs capacity can be combined freely
Perfect alarm system & reliable earthing protection
Suit for frame, box and cabinet
Buried-wire structure for saving operation space
ST0-399 Test block
8/10 pairs capacity can be combined freely
Suit for frame, box and cabinet
Buried-wire structure for saving operation space
FA9-399 Protector
Open-circuit protection
Perfect first-protection with rapid action
Under certain conditions, the protector can rework by
restoration switch after fail-protection
Reliable protection against over-voltage & over-current
Remarks:The ordering information for product above refer to Page 14
.
Features
SUNSEA TELECOMMUNICATIONS CO.,LTD.
Distributing Solutions For System Line & Surbscriber
JPX399 Double-sided Main Distribution Frame
Ordering information
Remarks Increasing a row of MDF leads to another one test block per row, width increasing 250mm accordingly
Guardrail is optional when the frame column over 4
SUNSEA TELECOMMUNICATIONS CO.,LTD.
External line Internal line Specifications
Name Model Maximumcapacity(pairs)
ColumnProtective
block/column
Maximumcapacity(pairs)
RowTest
block/row
H W D(mm)
Weight(Kg)
Remarks
SS4.102.D00 JPX399-A1-2 6 1200 2 6 768 6 21900 500 810
without guardrail37.7
SS4.102.D01 JPX399-A1-2 8 1600 2 8 1024 8 22390 500 810
without guardrail 54
SS4.102.D02 JPX399-A1-2 10 2000 2 10 1280 10 22850 500 810
without guardrail64.7
SS4.102.D03 JPX399-A1-2 12 2400 2 12 1536 12 23330 500 810
without guardrail71.3
AdoptingFA8-399-10A10AProtec tive block,
ST0-399-08 16
Test block.
SpecificationsName Code Model
H W D(mm)
capacity (pairs) Remarks
SS4.811.157 FA9-399-05 18.6 9.6 8.3 1 PPTCR, GDTProtector
SS4.811.158 FA9-399-06 18.6 9.6 8.3 1 PPTCR, SA
Distributing Solutions For System Line & Surbscriber
SpecificationsName Code Model
Maximumcapacity(pairs) H W D(mm)
Remarks
SS4.812.000 ST0-399-08 8 20.2 104 53
SS4.812.001 ST0-399-10 10 20.2 123.2 53
SS4.812.002 ST0-399-08 8 20.2 104 53 including mark
SS4.812.113 ST0-399-10G 10 20.2 123.2 49.5
Test module
SS4.812.118 ST0-399-08G 8 20.2 104 49.5
SS4.812.100 FA8-399-08A 8 with alarm disconnection plug
SS4.812.101 FA8-399-08B 8 with alarm connection plug
SS4.812.102 FA8-399-08C 8 without alarm disconnection plug
SS4.812.103 FA8-399-08D 8
20.2 104 53
without alarm connection plug
SS4.812.104 FA8-399-10A 10 with alarm disconnection plug
SS4.812.105 FA8-399-10B 10 with alarm connection plug
SS4.812.106 FA8-399-10C 10 without alarm disconnection plug
SS4.812.107 FA8-399-10D 10
20.2 123.2 53
without alarm connection plug
SS4.812.109 FA8-399-10AG 10 20.2 123.2 49.5 with alarm disconnection plug
SS4.812.110 FA8-399-10BG 10 20.2 123.2 49.5 with alarm connection plug
SS4.812.111 FA8-399-10CG 10 20.2 123.2 49.5 without alarm disconnection plug
SS4.812.112 FA8-399-10DG 10 20.2 123.2 49.5 without alarm connection plug
SS4.812.114 FA8-399-08AG 8 20.2 104 49.5 with alarm disconnection plug
SS4.812.115 FA8-399-08BG 8 20.2 104 49.5 with alarm connection plug
SS4.812.116 FA8-399-08CG 8 20.2 104 49.5 without alarm disconnection plug
Protectivemodule
SS4.812.117 FA8-399-08DG 8 20.2 104 49.5 without alarm connection plug
SS4.079.751 ST0-399-08 08 64 176 88.4 56
SS4.079.752 ST0-399-08 12 96 264 88.4 56
SS4.079.753 ST0-399-08 16 128 352 88.4 56
without alarm suitable for 8-pair test block protective
block without alarm
SS4.079.759 ST0-399-10 10A 100 242 107.6 56without alarm suitable for 10-pair test block protective
block without alarm,with block flag
SS4.079.754 ST0-399-10 10 100 220 107.6 56without alarm suitable for 10-pair test block protective
block without alarm
SS4.079.781 FA8-399-08 12 96 264 88.4 56 with alarm suitable for 8-pair protective block with alarm
SS4.079.782 FA8-399-10 10 100 220 107.6 56with alarm suitable for 10-pair protective block with
alarm
SS4.079.783 FA8-399-10 10A 100 242 107.6 56with alarm suitable for 10-pair protective block with
alarm , with block flag
Rear rack
SS4.079.757 FA8-399-10 10A 100 242 107.6 56with alarm suitable for 10-pair protective block witho ut
alarm , with block flag
JPX399-B
Can be installed against the wall, or back to back
Perfect cable routing management system
Aluminum extrusion frame, assembled free of drilling, easy for combination and extension
Modularized frame structure, simple installation, manifold specification & capacity
Reliable protection against over-voltage & over-current
3-level audible & visible alarm system
Features
Ordering information
Remarks The ordering information of Protective block Test block and Protector refer to P14
SUNSEA TELECOMMUNICATIONS CO.,LTD.
JPX399-B Single-sided Main Distribution Frame
External line Internal line Specifications
Code Model Maximumcapacity(pairs)
ColumnProtective
block/column
Maximumcapacity(pairs )
RowTest
block/row
H W D(mm)
Weight(Kg)
Remarks
SS4.102.D20 JPX399-B1-1 6 600 1 6 512 1 4 1850 500 577 28.8
SS4.102.D21 JPX399-B1-1 8 800 1 8 640 1 5 2350 500 577 33.5
SS4.102.D22 JPX399-B1-1 10 1000 1 10 896 1 7 2850 500 577 40.3
Adopting FA8-399-10AProtective block & ST0-399-08X16 Test block.
Distributing Solutions For System Line & Surbscriber
JPX399-D
Modularized design, steel cabinet ,save space
Perfect cable routing management system
Different function blocks can be interchanged easily by the same installation
Reliable protection against over-voltage & over-current
2-level audible & visible alarm system
Excellent sealed performance
Features
Ordering information
Remarks The ordering information of Protective block Test block and Protector refer to P14
SUNSEA TELECOMMUNICATIONS CO.,LTD.
JPX399-D MDF Cabinet
External line Internal line Specifications
Code Model Maximumcapacity(pairs)
ColumnProtective
block/column
Maximumcapacity(pairs)
RowTestblock/row
H W D(mm)
Weight(Kg)
Remarks
SS4.100.080 JPX399-D1 2400 2 12 2560 2 10 2600 600 600 133
SS4.100.081 JPX399-D2 1800 2 9 1792 2 7 2000 600 600 102.3
SS4.100.082 JPX399-D3 2000 2 10 2048 2 8 2200 600 600 112.5
Adopting FA8-399-10AProtective block & ST0-399-08X16 Testblock.
Distributing Solutions For System Line & Surbscriber
JPX399-E
Wall-mounted steel frame with shallow structure, save space
Perfect cable routing management system
Short installation time, thanks to preassembly rack
Modularized design, simple installation, manifold specification & capacity
Reliable protection against over-voltage & over-current
2-level audible & visible alarm system
Features
Ordering information
Remarks The ordering information of Protective block Test block and protector refer to P14
SUNSEA TELECOMMUNICATIONS CO.,LTD.
JPX399-E Wall-mounted Main Distribution Frame
External line Internal line Specification
Code Mode Maxcapacity(pairs)
ColumnProtective
block/column
Maxcapacity(pairs)
ColumnTest
block/column
H W D(mm)
Weight(Kg)
Remarks
SS4.102.D60 JPX399-E1-1 4 400 1 4 320 1 5 1120 500 160 9
SS4.102.D61 JPX399-E1-1 5 500 1 5 384 1 6 1340 500 160 11
SS4.102.D62 JPX399-E1-1 6 600 1 6 448 1 7 1560 500 160 13
SS4.102.D63 JPX399-E1-1 8 800 1 8 512 1 8 2000 500 160 16.5
SS4.102.D64 JPX399-E1-1 10 1000 1 8 768 1 12 2440 500 160 20
AdoptingFA8-399-10A10Protective block & ST0-399-08X8 Testblock
Distributing Solutions For System Line & Surbscriber
JPX399-F
Wall-mounted steel box with shallow structure save space
Perfect cable routing management system
Modularized design, simple installation, manifold specification & capacity
Reliable protection against over-voltage & over-current
2-level audible & visible alarm system
Excellent sealed performance
Features
Remarks The ordering information of Protective block Test block and Protector refer to P14
Ordering information
SUNSEA TELECOMMUNICATIONS CO.,LTD.
JPX399-F Wall-mounted MDF Box
External line Internal line Specification
Code Mode Maxcapacity (Pairs)
ColumnProtective
block/column
Maxcapacity (Pairs)
ColumnTest
block/column
H W D(mm)
Weight(Kg)
Remarks
SS4.100.A30 JPX399-F1 200 1 2 160 1 2 620 480 150 14.4
SS4.100.A31 JPX399-F2 400 1 4 320 1 4 1060 480 150 23.8
AdoptingFA8-399-10X10AProtective block &ST0-399-08X10Test block
Distributing Solutions For System Line & Surbscriber
M19-C
5U height, 19 standard installation
Module capacity and format can be deployed freely
Configured in B-type or D-type module, the Protective block can work without Protector
Ordering information
Remarks The audible & visible alarm needs mounted with column alarm and general alarm
The ordering information of Protective block Test block and Protector refer to P14
Features
SUNSEA TELECOMMUNICATIONS CO.,LTD.
M19-C Series Unit
External line Internal line Specifications
Name Model
ModuleMaximumcapacity(pairs)
ModuleMaximumcapacity(pairs)
H W D(mm)
Alarm Remarks
M19-C01 ----- ----- ST0-399-10 200 221.5 486 85 -----
M19-C02 ----- ----- ST0-399-08 160 221.5 486 85 -----
M19-C10A FA8-399-10A 200 ----- ----- 221.5 486 85 Yes FA8-399-10B available
M19-C10C FA8-399-10C 200 ----- ----- 221.5 486 85 ----- FA8-399-10D available
M19-C11A FA8-399-10A 100 ST0-399-10 100 221.5 486 85 YesExternal line module canreplace FA8-399-10B
M19-C11C FA8-399-10C 100 ST0-399-10 100 221.5 486 85 -----External line module can replace FA8-399-10D
M19-C12A FA8-399-10A 100 ST0-399-08 80 221.5 486 85 YesExternal line module can use FA8-399-10B
19 MDF
unit
M19-C12C FA8-399-10C 100 ST0-399-08 80 221.5 486 85 -----External line module can use FA8-399-10D
Distributing Solutions For System Line & Surbscriber
TZ-399-1ZT-399
Ordering information
Remarks The ordering information of general tool refer to P11
HD-399 TD-399-1
SUNSEA TELECOMMUNICATIONS CO.,LTD.
JPX399 Accessories
SpecificationsName Code Model
H W D(mm)
Capacity(pairs)
Weight(g)
Remarks
Disconnection test cord for test block
SS3.695.209 TD-399-1 L=3m 127.44 -core, crocodile clamps.Offer disconnection test function.
Online test cord SS3.695.211 TZ-399-1 L=3m 127.6Crocodile clamps.Offer online test function.
Connection plug for protective block
SS3.645.091 ZT-399 18.6 9.6 77.5 1 5.5
Disconnection plug for test block
SS3.645.251 HD-399 14 7.8 50 1 1.4
Earthing plug SS3.695.220 JD-399 18.6 9.6 77.5 1 1.5
Distributing Solutions For System Line & Surbscriber
JPX38-2-B
ZP-25
FA9-199
HP-32
Brief
Features
Benefit from high-density and large capacity, JPX38-2 series products are designed for medium-sized & small capacity
applications, especially suitable for 19-inch cabinet.
Single-sided steel frame, shallow structure designed for saving the space,
and suitable for medium-sized & small exchange
Rich routing space, perfect cable routing management system
Convenient for frame combination and extension
Protective block and Test block are alternant installed, so that to shorten jumper
Rotary mounting-rack designed, convenient to operate
Reliable protection against over-voltage & over-current
3-level audible & visual alarm system
Parallel mounting, back-to-back mounting, or corner mounting is available
Remarks:The ordering information for product above refer to Page 23
General alarm
Distributing Solutions For Medium-sized & Small Capacity
21
SUNSEA TELECOMMUNICATIONS CO.,LTD.
JPX38-2 Single-sided Main Distribution Frame
JPX38-2-D
ZP-25
HP-32
FA9-199
HP-32 Test block
Buried-wire structure for saving operation space
Suitable for box, cabinet, especially for 19
installing frame
FA9-199 Protector
ZP-25 Protective block
Compact structure and high density
Perfect alarm system and reliable earthing system
Buried-wire structure for saving operation space
Suitable for box, cabinet, especially for 19
installing frame
Patented open-circuit protection technology
Perfect first protection with rapid action
Under certain conditions, the Protector can rework
by restoration switch after fail-protection
Reliable protection against over-voltage & over-current
Remarks:The ordering information for product above refer to Page 23
Features
SUNSEA TELECOMMUNICATIONS CO.,LTD.
Distributing Solutions For Medium-sized & Small Capacity
Ordering information
SpecificationsName Code Model
H W D(mm)
Capacity(pairs)
Weight(g)
Remarks
Protective block SS3.691.032 ZP25Y 28 300 60 25 240 One-side operations, single slot, and with alarm.
Test block SS3.691.233 HP32Y 20 300 56 32 151.2 Single slot
SS4.811.059 FA9-199-5 16 10 68 1 9.3 PPTCR, GDTProtector
SS4.811.060 FA9-199-6 16 10 68 1 9.3 PPTCR, SA
Distributing Solutions For Medium-sized & Small Capacity
23
SUNSEA TELECOMMUNICATIONS CO.,LTD.
JPX38-2 Single-sided Main Distribution Frame
Subscriber lines Internal lines Specifications
Code Model Maximumcapacity(pairs)
Modules/columnMaximumcapacity(pairs)
Modules/row H W D(mm)
Remarks
SS4.102.061 JPX38-2-B3 1200 48 960 30 2200 550 300
SS4.102.068 JPX38-2-B2A 1000 40 672 21 2000 530 330
SS4.100.061 JPX38-2-D3 1200 48 960 30 2200 600 300
SS4.100.062 JPX38-2-D5 2400 96 1920 60 2200 980 300
SUNSEA TELECOMMUNICATIONS CO.,LTD.
Distributing Solutions For Medium-sized & Small Capacity
ZT-3Y HD-C1 ZC-C11Y
Ordering information
Remarks:The ordering information of general tools infer to P11
HC-D11HC-B1
JPX38-2 Accessories
SpecificationsCode Model
Capacity(pairs)
H W D(mm)
Weight(g)
RemarksName
SS3.695.035 ZC-C11Y 1 L=3m 109 Crocodile clamps Suitable for ZP25 protective block
SS3.695.202 HC-B1 1 L=3m 99.4 Crocodile clamps Suitable for ST0-199-10 20 Test
blockTest cord for Testblock
SS3.695.232 HC-D11 1 L=3m 131 Crocodile clamps
Disconnection plug for Test block
SS3.645.231 HD-C1 1 47.5 7.5 8.5 0.5
Connection plug for Protective block
SS3.645.032 ZT-3Y 1 16 10 67 6
Distribution Solution For Center Office
ZG-B2
ST0-210-08X16
LG-B2
Brief
Having excellent reliability, JPX38 MDF products provide a high-density & large capacity solution for various exchange
to satisfy the various demands.
Double-sided frame, enough routing space, perfect cable routing management system
Aluminum extrusion frame, assembled free of drilling, easy for combination and extension
Modularized design, simple installation, manifold specification & capacity
Rotary structure in Protection block, easy for operation
Large-capacity and high-density as small volume block
Reliable protection against over-voltage & over-current
4-level audible & visual alarm system
Features
JPX38-A
Remarks:The ordering information for product above refer to P27
FA8-59-1
FA9-47
SUNSEA TELECOMMUNICATIONS CO.,LTD.
JPX38 Double-sided Main Distribution Frame
Distribution Solution For Center Office
FA9-47 Protector
Open-circuit protection
Perfect first protection with rapid action
Under certain conditions, the Protector can rework
by restoration switch after fail-protection
Perfect protection against over-voltage & over-currentFA9-47
ST0-210-08X16
FA8-59-1
FA8-59-1 Protective block
Copper-alloy terminal tags have perfect conductivity
and elasticity, and with envelope structure
Rotary structure easy to operate
Perfect alarm system and reliable earthing system
Clear line identification
ST0-210-08X16 Test block
Copper-alloy terminal tags have perfect conductivity
and elasticity, and with envelope structure
Clear line identification
Flexible installation
Remarks: The ordering information for product above refer to P27
Features
SUNSEA TELECOMMUNICATIONS CO.,LTD.
Ordering information
Remarks Increasing a row of MDF leads to another one test block per row, width increasing 250mm accordingly
Guardrail Is optional when column over 4
SUNSEA TELECOMMUNICATIONS CO.,LTD.
JPX38 Double-sided Main Distribution Frame
SpecificationName Code Model
H W D (mm)
Capacity(pairs)
Remarks
Protective block SS3.691.007 FA8-59-1Y 225 110 160 100 Mounting draw-pole, with alarm.
SS3.691.313 ST0-210-08 16A 106 200 93 128 Suit for 2# aluminum extrusion
SS3.691.314 ST0-210-08 16B 106 200 93 128 Suit for 1# aluminum extrusionTest block
SS3.691.295 HP-D8-128Y 127.5 252 80 128 Suit for JPX38-DA
SS4.811.028 FA9-47-8 10.4 18.0 53 1 PPTCR SAProtector
SS4.811.029 FA9-47-10 10.4 18.0 53 1 PPTCR GDT
Subscriber lines Internal lines Specification
Code Model Maximumcapacity(pairs)
ColumnProtective
block/column
Maximumcapacity(pairs)
RowTest
block/row
H W D (mm)
Weight(Kg)
Remarks
SS4.102.014 JPX38-A3-2 6 1200 2 6 1024 4 22153 500 920
without guardrail51.3
SS4.102.015 JPX38-A3-2 8 1600 2 8 1536 6 22153 500 920
without guardrail54.3
SS4.102.016 JPX38-A3-2 10 2000 2 10 2048 8 22605 500 920
without guardrail65.7
SS4.102.017 JPX38-A3-2 12 2400 2 12 2560 10 23057 500 920
without guardrail71.8
AdoptingFA8-59-1Protectiveblock & ST0-210 Test block
Distribution Solution For Center Office
SUNSEA TELECOMMUNICATIONS CO.,LTD.
Distribution Solution For Center Office
Ordering information
ZT-2Y HC-210A-11
Remarks:The ordering information of general tools refer to P6
HD-210A
JPX38 Accessories
SpecificationName Code Model
Capacity(pairs) H W D(mm)
Weight(g)
Remarks
Test cord for Protective block
SS3.695.036 ZC-B1Y 1 L=3m 103 Crocodile clamps Suit for FA8-59 Protective block
SS3.695.202 HC-B1 1 L=3m 99 Crocodile clamps With disconnect testSuit for HP32 Test b lock.Test cord for Test
blockSS3.695.231 HC-D1 1 L=3m 111 Crocodile clamps With online test, suit for HP-D8-128 Test b lock.
SS3.695.219 HC-210A-11 1 L=3m 121.6Online test cord
SS3.695.225 HC-210A-12 1 L=3m 137
SS3.645.201 HD-A1 1 42 8.4 9.0 0.5Suit for single-slot
Test blockSuit for HP-D8-128 HP-D10-100, with test rope
SS3.645.273 HD-210A 1 49 3 9.5Suit for double-slot
Test blockSuit for HD-210A
Disconnectionplug for Test block
SS3.695.226 HC-210A-21 1 L=3m 121.6
Connection plug for Protective
blockSS3.645.033 ZT-2Y 1 71 18 10.4 8 Suit for FA8-59
Test cord socket SS3.665.000 CZ-A1 60 150 40.5 627 Suit for test plug
Earthing plug SS3.645.300 JD-47 46.5 17.8 10.4Suit for FA8-59Protective block
XF5-85-B
The XF5-85-B Cross connection box adopts ST0-399-10 modules, has both superior connection of system distribution
and convenient operation of subscriber, and is designed for the outdoor rough environment. The product is suitable for
the connection between main cables and distribution cables of local telephone net.
Brief
Steel box is design for outdoor environment
ST0-399-10 module offer superior connection
Excellent sealed material
2-point latched waterproof lock, padlock is available outside
Features
Remarks:The ordering information for product above refer to Page 30
29
SUNSEA TELECOMMUNICATIONS CO.,LTD.
XF5-85-B Cross Connection Box
Distributing Solutions For Subscriber
SUNSEA TELECOMMUNICATIONS CO.,LTD.
Distributing Solutions For Subscriber
Ordering information
Remarks:The ordering information of Protective block, Test block& Protector refer to P14
XF5-85-B Cross Connection Box
Specifications
Name Code Model Maximumcapacity(pairs)
ModuleSingle-sided
columnH W D (mm)
Remarks
SS2.108.A52 XF5-85-B1-400 400 40 2 980 500 300
SS2.108.A53 XF5-85-B1-600 600 60 3 980 725 300
SS2.108.A54 XF5-85-B1-900 900 90 3 1200 725 300
SS2.108.A50 XF5-85-B1-1200 1200 120 4 1200 950 300
SS2.108.A51 XF5-85-B1-1600 1600 160 4 1400 950 300
Floor Single-sidedcross connection
box
SS2.108.A90 XF5-85-B1-2000 2000 200 5 1400 1175 300
SS2.108.A58 XF5-85-B2-1200 1200 120 3 1100 725 350
SS2.108.A60 XF5-85-B2-1800 1800 180 3 1300 725 350
SS2.108.A55 XF5-85-B2-2400 2400 240 4 1300 950 350
Floor double-sidedcross connection
box
SS2.108.A56 XF5-85-B2-3200 3200 320 4 1500 950 350
SS2.108.A70 XF5-85-B3-400 400 40 2 750 450 250
SS2.108.A71 XF5-85-B3-600 600 60 3 750 675 250
Wall-mountedcross connection
boxSS2.108.A72 XF5-85-B3-900 900 90 3 970 675 250
JPX399-H1-100 JPX399-H2-100
JPX399-H Distribution box adopts FA8-399-10D module, has both superior connecting ability of system side and
convenient use of subscriber is designed for rough environment of subscriber and is suitable for connection be-
tween distribution cable and subscriber cable of local telephone net. According to the different application areas, it
has indoor and outdoor versions.
Steel box, suitable for outdoor environment
FA8-399-10D module provides excellent connection characteristic
The outdoor type use superior sealed material and waterproof lock
The indoor type use FA9-399 Protector, which offer reliable protection again over-voltage and over-current
Features
Ordering information
Remarks:The ordering information of Protection block, Test block& Protector refer to P14
Brief
Distributing Solutions For Subscriber
SUNSEA TELECOMMUNICATIONS CO.,LTD.
JPX399-H Distribution Box
Module SpecificationsName Code Model
Maximumcapacity (pairs)
Number H W D(mm)
Remarks
SS2.108.A00 JPX399-H1-100 100 10 320 262 130
SS2.108.A01 JPX399-H1-50 50 5 210 262 130
Indoordistribution
boxSS2.108.A02 JPX399-H1-200 200 20 540 262 130
Default mounting:FA8-399-10D,
or choose ST0-399-10
FA8-399-10C
Protector FA9-399 05/06
SS2.108.A20 JPX399-H2-100 100 10 380 300 130
SS2.108.A21 JPX399-H2-50 50 5 270 300 130
Outdoordistribution
boxSS2.108.A22 JPX399-H2-200 200 20 600 300 130
Defaultmounting:FA8-399-10D,
or choose ST0-399-10
FA8-399-10C.
SUNSEA TELECOMMUNICATIONS CO.,LTD.
Distributing Solutions For Subscriber
XF5-85-A Cross connection box adopts the rotate IDC modules, is easy to operate without special tool, and suitable
for connection between main distribution cable and cable of local telephone net.
Brief
XF5-85-A Cross Connection Box
XF5-85-A
FeaturesSteel box suitable for outdoor environment
Rotatry IDC module is convenient for maintenance & connection
Double-sided chromatogram connecting plug
Excellent sealed material
Two-point latched waterproof lock, padlock is available outside
Ordering information
Distributing Solutions For Subscriber
SUNSEA TELECOMMUNICATIONS CO.,LTD.
SpecificationsName Code Model
Maximumcapacity(pairs)
NumberSingle-sided
columnH W D(mm)
Remarks
SS2.108.A86 XF5-85-A1-200 200 2 1 820 650 300
SS2.108.A87 XF5-85-A1-400 400 4 2 1060 650 300
SS2.108.A82 XF5-85-A1-600 600 6 3 1060 900 300
SS2.108.A81 XF5-85-A1-900 900 9 3 1300 900 300
Single-sidedcross
connection box
SS2.108.A80 XF5-85-A1-1200 1200 12 4 1300 1100 300
SS2.108.A88 XF5-85-A2-800 800 8 2 1110 700 350
SS2.108.A84 XF5-85-A2-1200 1200 12 3 1110 950 350
SS2.108.A85 XF5-85-A2-1800 1800 18 3 1350 950 350
SS2.108.A83 XF5-85-A2-2400 2400 24 4 1350 1200 350
Double-sidedcross
connection box
SS2.108.A89 XF5-85-A2-3200 3200 32 4 1600 1200 400
Adopting25 pairs rotary IDC module, the basic unit is 100 pairs.
SUNSEA TELECOMMUNICATIONS CO.,LTD.
Distributing Solutions For Subscriber
XF0-49-A Distribution box adopts the rotary IDC module is easy to operate without special tool, and suitable for con-
nection between distribution cable and subscriber cable of local net. According to working environment it has
indoor and outdoor versions.
Brief
The indoor box with steel shell, and offer superior coating protection ability
The outdoor box has aluminum alloy or SMC shell to be chosen, suitable for outdoor rough environment
IP43 protection class
Rotary IDC module can work without special tool
Rotary structure, exposed test port for convenient testing
Wall-mounted or pole-mounted is available
Features
Ordering information
XF0-49-A Distribution Box
XF0-49
SpecificationsName Code Model
H W D(mm)
Capacity(pairs)
Remarks
Z, FXH, 5L XF0-49-A1-5 160 125 93 5
Z, FXH, 10L XF0-49-A1-10 175 140 93 10
Z, FXH, 20L XF0-49-A1-20 270 150 93 20
Z, FXH, 30L XF0-49-A1-30 270 225 93 30
Z, FXH, 50L XF0-49-A1-50 270 225 93 50
Outdoor style, aluminum alloy shell
Z, FXH, 10B XF0-49-A2-10 175 140 93 10
Z,FXH,20B XF0-49-A2-20 270 150 93 20
Z,FXH,30B XF0-49-A2-30 270 225 93 30
Z,FXH,50B XF0-49-A2-50 270 225 93 50
Outdoor style, SMC shell
Z,FXH,10G XF0-49-A3-10 145 120 60 10
Z,FXH,20G XF0-49-A3-20 235 143 80 20
Z,FXH,30G XF0-49-A3-30 235 215 80 30
Distribution box
Z,FXH,50G XF0-49-A3-50 235 215 80 50
Indoor style, steel shell
Application
Ad
ditio
na
lsu
bscrib
er
jum
pe
r
Additional Test block2
DSLAM audio cable
DSLAM data cable
Test block1
SPL
PSTN switch Protective Block MODEM
Telephoneof subscriber
DSLAM equipment
PS
TN
The broadband business, especially ADSL, is boomed in China. Meanwhile, it will challenge the capacity of the telecom
room, especially in the large telecom center office. Considering for the profit of the operators, we offer a series of solu-
tions for ADSL distribution.
Traditional solution of ADSL broadband distribution
Many contact points lead to high failure rate
Complex installation and distribution, low efficiency
More occupying area as low intensity of block
Limited by the sparing area of the original center office as the adding of cables and equipments
Features
Computerof subscriber
Ad
ditio
na
lju
mp
er
Additional Test block3
PSTN subscriberDisconect as the ADSL is added
SUNSEA TELECOMMUNICATIONS CO.,LTD.
ADSL Broadband Distribution Solutions
Traditional Solution of ADSL Broadband Distribution
SUNSEA TELECOMMUNICATIONS CO.,LTD.
ADSL Broadband Distribution Solutions
Application
ADSL high-density distribution module is designed to solve the problem that we need a larger capacity in a small room.
Compared to traditional test block, it doubles the capacity while occupies the same space as traditional test block. It
is suitable for the case that there is not any SPL splitter integrated in DSLAM equipments in telecom rooms.
1. ADSL high-density distribution module
Keep the distribution cable as usual
Module's length is small than tradition test block, and then is convenient to improve the frame
Can double the capacity while occupies the same space as traditional test block
The ADSL high-density distribu tion block might be instead by two aditional test block or an original test block
Features
Ad
ditio
na
lsu
bscrib
er
jum
pe
r
Additional Test block2
Test block1
SPL
PSTN switch Protective block MODEM
Telephoneof subscriber
DSLAM equipment
PS
TN
Computerof subscriber
Ad
ditio
na
lju
mp
er
Additional Test block3
DSLAM data cable
DSLAM audio cable
PSTN subscriberDisconect as the ADSL is added
ADSL High-density Distribution Module
Considering to the limitation of traditional ADSL solution,SUNSEA provides a series of ADSL distribuion solutions.
Copper-alloy terminal tags have perfect conductivity and elasticity
Prevent accidental line connection
Clear line identification
Double or more module density than traditional Test block
Features
Ordering information
ST0-210-16 16
HC-210-11HD-210
SUNSEA TELECOMMUNICATIONS CO.,LTD.
ADSL High-density Distribution Module
Accessories
37
ADSL Broadband Distribution Solutions
Specification Application
Name Code ModelL W H(mm)
DSLAMwithout
SPL
DSLAMwithSPL
Weight(g)
Remarks
ADSL high-density broadband distribution module
SS3.691.305 ST0-210-16 16 210 132 102 256 pairs
Online test cord SS3.695.213 HC-210-11 L=3m 103Crocodile clamps2-core aviation plug
Disconnection test cord for Test block
SS3.695.215 HC -210-21 L=3m 103Crocodile clamps4-core aviation plug
Disconnection plug SS3.645.271 HD-210 3 6.4 48 0.7
Insertion tool SS4.430.010 XD-B1 23.3 31.8 158.6 70.1
SUNSEA TELECOMMUNICATIONS CO.,LTD.
ADSL Broadband Distribution Solutions
Application 1
Brief
The ST0-210SC series broadband distribution solutions are applicable to distribution equipment for various
exchanges, used to separate low-frequency voice signals from high-frequency data signals and to implement
the simultaneous transmission of data signals over the traditional PSTN communication lines.
ST0-210SC Series New Broadband Distribution Solutions
Module capacity can be deployed freely
Convenient, rapid and reliable operation
Free switchover between narrowband and broadband services
Easy operations, installation and maintenance
Application Wide, Including adding new broadband services to the old central offices , as well as the deploying
new central offices
Preventing hidden troubles arising from cable movement due to module reversal
Advantages
The existing narrowband service equipment room is deployed with broadband service, and the ST0-210SC
broadband distribution module is used for cable distribution, Figure 1:
Improving the DSLAM integration
Reducing the used-number of distribution devices and distribution cables
Saving space, and facilitating management and maintenance
Features
DSLAM
MDF
Protective block
Subscriber line
Voice +Data
MDF
Test blockExchanger
Voice
Voice
Voice +Data
ST0-210SCblock
Splitter
+
Voice +Data
Figure 1
SUNSEA TELECOMMUNICATIONS CO.,LTD.
Application 2
The cable distribution is as shown in Figure 2 when the new equipment room adopts the ST0-210SC broadband distribution
module, and meanwhile when ordinary voice services and data services are deployed. Figure 2
If the equipment room has a smaller capacity,the wiring mode as shown in Figure3 can be used to save cost.Figure3:
ADSL Broadband Distribution Solutions
DSLAM
MDF
Protective block
Voice +Data
Voice +Data
Splitter
+
ST0-210SCblock
Voice
Exchanger
Voice +Data
MDF
Test block
Voice +Data
Subscriber line
DSLAM
MDF
Protective block
Voice +Data
Voice +Data
Splitter
+
ST0-210SCblock
Voice
Exchanger
Voice +Data
Voice +Data
Subscriber line
Figure 2
Figure 3
ADSL Broadband Distribution Solutions
SUNSEA TELECOMMUNICATIONS CO.,LTD.
Flexible structure, easy to be interchanged
IDC module,without special tool
The splitter (SPL) supports Insertion/withdrawal, the traditional narrowband voice services can operate
without splitter
Operating the termination, disconnection and testing while voice splitter Inserting
Buried-wire structure for saving operation space
Excellent wire lead systam
Standards Compliance: YD/T 694-2004
Brief
ST0-210SC broadband distribution module is composed of rear rack,
ST0-210SC-08A1 module bar, and so on. It cooperates with the ST0-210SC
series splitters.
ST0-210SC Series Broadband Distribution Modules
Features
The ST0-210SC series splitters are used in cooperation with the ST0-210SC series broadband distribution
modules. They are applicable to telephone switches of small/medium-sized capacity in central office terminals
and module offices, supporting such functions as distribution, testing, and separation of low-frequency voice
signals from high-frequency data signals.
ST0-210SC Series Splitters
Standards Compliance:
ETSI TS 101 952-1-1 V1.2.1,UL 1950
Brief
SUNSEA TELECOMMUNICATIONS CO.,LTD.
Online Test Cord
Accessories
The TZ-210SC-11 online test cord can implement online testing of communication
lines without the need of pulling out the voice splitter.
TZ-210SC-11A
The HD-210SC disconnection plug is inserted into the ST0-210SC-08A1 module
bar to disconnect communication lines.
Disconnection Plug
HD-210SC
ADSL Broadband Distribution Solutions
Ordering information
Name Code Model Dimensions Remarks
SS4.812.121 ST0-210SC-08A1 19.6 133 96Without groundingsystem
Module
SS4.812.122 ST0-210SC-08A1K 19.6 133 96 With grounding system
SS4.079.790 ST0-210SC-08A1 6 132 121.4 82
SS4.079.792 ST0-210SC-08A1 8 176 121.4 82
SS4.079.794 ST0-210SC-08A1 9 198 121.4 82
SS4.079.796 ST0-210SC-08A1 12 244 121.4 82
Back Framekit
SS4.079.C04 ST0-210SC-08A1 16 352 121.4 82
Without label
SS4.079.C00 ST0-210SC-08A1 6A 154 121.4 82
SS4.079.C01 ST0-210SC-08A1 8A 198 121.4 82
SS4.079.C02 ST0-210SC-08A1 9A 220 121.4 82
SS4.079.C03 ST0-210SC-08A1 12A 286 121.4 82
Back Framekit
SS4.079.C05 ST0-210SC-08A1 16A 372 121.4 82
With label
Note:These module and back frame kit are packed and transported sepeartely.
ADSL Broadband Distribution Solutions
SUNSEA TELECOMMUNICATIONS CO.,LTD.
SpecificationName Code Model Capacity
L H D(mm)Packing
Online test cord SS3.695.240 TZ-210SC-11A 1 Loop Length:3mCarton15pieces each
Disconnection plug SS3.645.274 HD-210SC 1 Loop 94 12 10Carton20pieces each
Ordering information
SpecificationName Code Model
L H D(mm)Standard Impedance Remarks
ADSL2 + Splitter SS4.815.008 ST0-210SC-A1 93.1 12 10 ETSI TS 101 952-1-1
ADSL2 + 16KHz Splitter SS4.815.009 ST0-210SC-B1 93.1 12 10 ETSI TS 101 952-1-1
ADSL2 + Splitter SS4.815.006 ST0-210SC-C 93.1 12 10 YD/T1187-2005
ADSL2 + 16KHz Splitter SS4.815.007 ST0-210SC-D 93.1 12 10 YD/T1187-2005
VDSL2 Splitter SS4.815.010 ST0-210SC-E 93.1 12 10 YD/T1187-2005
VDSL2 Splitter SS4.815.011 ST0-210SC-F 93.1 12 10 ETSI TS 101 952-2-1
VDSL2 + 16KHz Splitter SS4.815.012 ST0-210SC-G 93.1 12 10 ETSI TS 101 952-2-1
600 ohmBlue
ADSL2 + Splitter SS4.815.013 ST0-210SC-H 93.1 12 10 ETSI TS 101 952-1-1
ADSL2+ 16KHz Splitter SS4.815.014 ST0-210SC-I 93.1 12 10 ETSI TS 101 952-1-1
VDSL2 Splitter SS4.815.015 ST0-210SC-J 93.1 12 10 ETSI TS 101 952-2-1
VDSL2 16KHz Splitter SS4.815.016 ST0-210SC-K 93.1 12 10 ETSI TS 101 952-2-1
ADSL2+ OVER ISDN Splitter SS4.815.017 ST0-210SC-L 93.1 12 10 ETSI TS 101 952-1-3
VDSL2 OVER ISDN Splitter SS4.815.018 ST0-210SC-M 93.1 12 10 ETSI TS 101 952-2-3
OPTIONA
Green
ADSL2+ Splitter SS4.815.019 ST0-210SC-N 93.1 12 10 ETSI TS 101 952-1-1
ADSL2+ 16KHz Splitter SS4.815.020 ST0-210SC-O 93.1 12 10 ETSI TS 101 952-1-1
VDSL2 Splitter SS4.815.021 ST0-210SC-P 93.1 12 10 ETSI TS 101 952-2-1
VDSL2 16KHz Splitter SS4.815.022 ST0-210SC-Q 93.1 12 10 ETSI TS 101 952-2-1
ADSL2+ HP+LP Splitter SS4.815.023 ST0-210SC-R 93.1 12 10 ETSI TS 101 952-1-2
ADSL2+ HP+LP 16KHz Splitter SS4.815.024 ST0-210SC-S 93.1 12 10 ETSI TS 101 952-1-2
VDSL2 HP+LP Splitter SS4.815.025 ST0-210SC-T 93.1 12 10 ETSI TS 101 952-2-2
VDSL2 HP+LP 16KHz Splitter SS4.815.026 ST0-210SC-U 93.1 12 10 ETSI TS 101 952-2-2
OPTIONB
Black
Bridging Splitter SS4.815.027 ST0-210SC-V 93.1 12 10 White
WithoutK20
ADSL2+ Splitter SS4.815.036 ST0-210SC-A1K 93.1 12 10 ETSI TS 101 952-1-1
ADSL2+ 16KHz Splitter SS4.815.037 ST0-210SC-B1K 93.1 12 10 ETSI TS 101 952-1-1
VDSL2 Splitter SS4.815.038 ST0-210SC-FK 93.1 12 10 ETSI TS 101 952-2-1
VDSL2 16KHz Splitter SS4.815.039 ST0-210SC-GK 93.1 12 10 ETSI TS 101 952-2-1
600 ohm
Blue
ADSL2+ HP+LP Splitter SS4.815.032 ST0-210SC-RK 93.1 12 10 ETSI TS 101 952-1-2
ADSL2+ HP+LP 16KHz Splitter SS4.815.033 ST0-210SC-SK 93.1 12 10 ETSI TS 101 952-1-2
VDSL2 HP+LP Splitter SS4.815.034 ST0-210SC-TK 93.1 12 10 ETSI TS 101 952-2-2
VDSL2 HP+LP 16KHz Splitter SS4.815.035 ST0-210SC-UK 93.1 12 10 ETSI TS 101 952-2-2
OPTIONB
Black
Bridging Splitter SS4.815.028 ST0-210SC-VK 93.1 12 10 White
WithK20
Note:The splitter is packed with carton,800 pieces each.
CONTENTCONTENT
47MPX107-SM Digital Distribution Frame
49MPX109-FS Digital Distribution Frame
51MPX139-ZH Digital Distribution Frame
DDF >>
MPX112-SS Digital Distribution Frame 55
52General Tools
53Zh19 Unit
75 /120 Balun 54
Digital Distribution Frame
Digital distribution products, meet the need of different capacity in the telecom network whose transmit rate between
2M 155Mbit/s, can be widespread used between digital multiplexing equipments or between digital multiplexing
equipments and exchangers, providing function of distribution, transition and test.
Adopting general frame + connector units of different pattern structure, SUNSEA provides digital distribution
products including 75 , 120 or 75 /120 which are compatible with SIMENS and FS styles.
They can satisfy various demands.
Features
Steel or aluminum extrusion frame with open structure, and various specs for selection
Modularized design and suitable for different pattern units
Compact structure can enlarge capacity and operation space
Side-broad with unique structure is easy to assemble
Reliable earthing protection
The Unit has interchange ability & expansibility, and meets the need of business alteration
Patent: 90 rotatable position structure and guide auto-pushing position structure are convenient for cable's
fixing and termination
Coax connector offers online monitoring, and is easy to loop-back & test
Clear line identification
Compliant with YD/T1437-2006
Overview
Opticaltransmit
net
Transmittelecom room
Exchange Telecomcenter Customer
ODFMultiplexingequipment DDF
Switchequipment MDF
Digital Distribution Frame
SUNSEA TELECOMMUNICATIONS CO.,LTD.
Technical specification
Ambient condition
Working temperature -5 +55
RH : <85%(+30 )
Atmospheric pressure 70 106 KPa
Electrical Performances
Working rate Mbit/s 2 8 34 45 140 155
Connect resistance out-conductor 2.5 m in-conductor 5 m
Insulation resistance 1000 M
Dielectric strength 50Hz AC 1000 V/min No break down or flying arc
Cross talk 70 dB (50 KHz 233 MHz)
Attenuation 0.3 dB (50 KHz 3.1MHz )
Return loss 18 dB (50 KHz 3.1MHz )
Patent
The Digital Distribution Frame (DDF) of SUNSEA
has independent intellectual property rights, and
have researched and developed after analyzing
customers' various practical needs.
This kind of products applied 5 patents; all of them
were acquired accreditation and certification from
State Intellectual Property Office.
Product certification
Our DDF products have awarded certificates by TL
Certifications Center (TLC), who is the authority in
telecom field. TLC inspects our products and sup-
ervises our manufacture process annually.
Digital Distribution Frame
SUNSEA TELECOMMUNICATIONS CO.,LTD.
Pin
Test cord
Accessories
Connection cord
Brief
MPX107-SM products use 75Ù-impedance gilded coaxial connector with screw structure. They provide online
monitoring. It has 5-piece structure, whose outer is clamped and the inner is welded.
5-piece structure
SMA01
SMA01( Working)
MPX107-SMA
Earthing system
Digital Distribution Frame
SUNSEA TELECOMMUNICATIONS CO.,LTD.
MPX107-SM Digital Distribution Products
Ordering information
Digital Distribution Frame
SUNSEA TELECOMMUNICATIONS CO.,LTD.
Specification
Name Code Model
H W D(mm)
Configurable capacity Remarks
SS4.102.206 MPX107-SMA1 2600 480 450 416 systems, with 26 SMA01
SS4.102.207 MPX107-SMA2 2000 480 450 320 systems, with 20 SMA01
SS4.102.208 MPX107-SMA3 2200 480 450 352 systems, with 22 SMA01
Double sides
SS4.102.254 MPX107-SMB1 2600 480 300 208 systems, with 13 SMA01
SS4.102.255 MPX107-SMB2 2000 480 300 160 systems, with 10 SMA01
SS4.102.256 MPX107-SMB3 2200 480 300 176 systems, with 11 SMA01
Single side
SS4.102.257 MPX107-SMC1 2600 600 450 546 systems, with 26 SMA02
SS4.102.258 MPX107-SMC2 2000 600 450 420 systems, with 20 SMA02
SS4.102.259 MPX107-SMC3 2200 600 450 462 systems, with 22 SMA02
Double sides
SS4.102.260 MPX107-SMD1 2600 600 300 273 systems, with 13 SMA02
SS4.102.261 MPX107-SMD2 2000 600 300 210 systems, with 10 SMA02
Frame
SS4.102.262 MPX107-SMD3 2200 600 300 231 systems, with 11 SMA02
Single side
SS4.100.266 MPX107-SME1 2600 600 600 720 systems, with 36 SM19E
SS4.100.267 MPX107-SME2 2000 600 600 560 systems, with 28 SM19E
SS4.100.268 MPX107-SME3 2200 600 600 600 systems, with 30 SM19E
Double sides
SS4.100.263 MPX107-SMF1 2600 600 300 360 systems, with 18 SM19E
SS4.100.264 MPX107-SMF2 2000 600 300 280 systems, with 14 SM19E
Cabinet
SS4.100.265 MPX107-SMF3 2200 600 300 300 systems, with 15 SM19E
Single side
SS3.691.447 SMA01 130 422 101.5 16 systemsRotatable, suit for MPX107-SMA/B
SS3.691.448 SMA02 130 542 101.5 21 systemsRotatable, suit for MPX107-SMC/D
SS3.691.450 SMA03 130 542 101.5 20 systemsRotatable, suit for MPX107-SMC/D
SS3.691.449 SM19E 130 482 97 20 systems
SS3.691.451 SM19F 130 482 97 21 systems
SS3.691.453 SM19G 130 482 101.5 16 systems
SS3.691.454 SM19H 75 482 101.5 10 systems
SS3.691.455 SM19J 75 482 101.5 8 systems
Rotatable, 19 installation
SS3.691.452 SM04C 75 482 97 10 systemsRotatable, 19 installation,
U-shaped structure
Digitaldistribution
frame
Unit
SS3.691.955 SM1 110 145 60 8 systemsSuitable for 1# 2#
Aluminum extrusion
Name Code Model Specification Remarks
Crimping Pliers U,2,480-483-484,Y YJQ-A
Wire Stripping Pliers U 2 008 B MHT4095-008
Exchang Test Cord SS3.695.482 SM05B-1 L=3m
Test Cord SS3.695.484 SM05B-1 L=3m
Accessories
High-end pin & socket
MPX109-FS
Brief
Ordering information
MPX109-FS product's units with modularized structure, whose rotary device is convenient for cable termination. The
units use 75Ù-impedance coax connector, whose copper shield cover offers reliable shield and antisepsis ability. The
out-conductor and in-conductor of coax connector are welded.
FS19AG AFS19BG B
Low-end pin & socket
Accessories Earthing system
Test cord
Connection cord
Digital Distribution Frame
SUNSEA TELECOMMUNICATIONS CO.,LTD.
MPX109-FS Digital Distribution Products
SpecificationName Code Model
H W D(MM)
Configurable capacity Remarks
SS4.102.294 MPX109-FSB1 2600 480 450 208 systems, with 26 FSAG/A
SS4.102.295 MPX109-FSB2 2000 480 450 160 systems, with 20 FSAG/A
SS4.102.296 MPX109-FSB3 2200 480 450 176 systems, with 22 FSAG/A
Double sides
SS4.102.297 MPX109-FSC1 2600 480 300 104 systems, with 13 FSAG/A
SS4.102.298 MPX109-FSC2 2000 480 300 80 systems, with 10 FSAG/A
Digital distribution
frameFrame
SS4.102.299 MPX109-FSC3 2200 480 300 88systems, with 11 FSAG/A
Single side
Digital Distribution Frame
SUNSEA TELECOMMUNICATIONS CO.,LTD.
SpecificationName Code Model
H W D(MM)
Configurable capacity Remarks
SS4.102.300 MPX109-FSD1 2600 600 450 223 systems, with 26 FSAG02/A
SS4.102.301 MPX109-FSD2 2000 600 450 210 systems, with 20 FSAG02/A
SS4.102.302 MPX109-FSD3 2200 600 450 231 systems, with 22 FSAG02/A
Double sides
SS4.102.303 MPX109-FSE1 2600 600 300 136.5 systems, with 13 FSAG02/A
SS4.102.304 MPX109-FSE2 2000 600 300 105 systems, with 10 FSAG02/A
SS4.102.305 MPX109-FSE3 2200 600 300 115.5 systems, with 11 FSAG02/A
Single side
SS4.102.306 MPX109-FSF1 2600 520 450 260 systems, with 26 FS19BG/B
SS4.102.307 MPX109-FSF2 2000 520 450 200 systems, with 20 FS19BG/B
SS4.102.308 MPX109-FSF3 2200 520 450 220 systems, with 22 FS19BG/B
Double sides
SS4.102.309 MPX109-FSG1 2600 520 300 130 systems, with 13 FS19BG/B
SS4.102.310 MPX109-FSG2 2000 520 300 100systems, with 10 FS19BG/B
Frame
SS4.102.311 MPX109-FSG3 2200 520 300 110systems, with 11 FS19BG/B
Single side
SS3.691.497 FSA01Low-end unit
SS3.691.498 FSA01-1
422 97 64 8-systems, with 16 pins.
SS3.691.499 FSAG01High-end unit
SS3.691.500 FSAG01-1
422 119.6 64 8-systems, with 16 pins.
Rotatable, suit for MPX109-FSB/C
SS3.691.101 FSA02Low-end unit
SS3.691.102 FSA02-1
542 97 64 10.5 systems, with 21 pins.
SS3.691.103 FSAG02High-end unit
SS3.691.104 FSAG02-1
542 119.6 64 10.5 systems, with 21 pins.
Rotatable, suit for MPX109-FSD/E
SS3.691.507 FSA03Low-end unit
SS3.691.508 FSA03-1
542 97 64 10-systems, with 20 pins.
SS3.691.509 FSAG03High-end unit
SS3.691.510 FSAG03-1
542 119.6 64 10-systems, with 20 pins.
Rotatable, suit for MPX109-FSD/E
SS3.691.503 FS19BLow-end unit
SS3.691.504 FS19B-1
482 97 64 10-systems, with 20 pins.Rotatable, suit for MPX109-FSF/G
SS3.691.505 FS19BG
Digital distribution
frame
High-end unit
SS3.691.506 FS19BG-1
482 119.6 64 10-systems, with 20 pins.Rotatable, suit for MPX109-FSF/G
Name Code Model Specification Remarks
Wire Stripping Pliers U 2 008 B MHT4095-008
Exchang Test Cord SS3.695.532 FS02A-1 L=3m
Test Cord SS3.695.534 FS02B-1 L=3m
Accessories
ZHO1E(front)
MPX139-ZHC
Brief
Adopting 75 coax connector and impedance convert chip, the MPX139-ZH distribution products provide convenient
75 /120 convert function, suitable for connection between different impedances of telecom room and transmit room.
General frame suit for assembling different pattern unit
Abundant operation space, large capacity
Side-broad with unique structure is convenient for frame combination and extension
Interchangeable & expansible units have dust cover
90 rotatable position structure is convenient for cable fixing and termination
Using 75 coax connector& impedance convert chip, which can reduce the occupy space
Offer on-line test& monitor
Features
ZHO1E(back)
Accessories
ZH01E(working)
Earthing system
Digital Distribution Frame
SUNSEA TELECOMMUNICATIONS CO.,LTD.
MPX139-ZH Digital Distribution Products
Ordering information
Stippling pliers Crimping pliers Dismantling sleeve
Ordering information
Digital Distribution Frame
SUNSEA TELECOMMUNICATIONS CO.,LTD.
General tools
Specification
Name Code Model
H W D(mm)
Configurable capacity Remarks
SS4.102.361 MPX139-ZHB1 2600 600 450 400 systems With 20 ZH01D
SS4.102.362 MPX139-ZHB2 2000 600 450 320 systems With 16 ZH01D
SS4.102.363 MPX139-ZHB3 2200 600 450 360 systems With 18 ZH01D
SS4.102.364 MPX139-ZHC1 2600 480 450 320 systems With 20 ZH01E
SS4.102.365 MPX139-ZHC2 2000 480 450 256 systems With 16 ZH01E
Frame
SS4.102.366 MPX139-ZHC3 2200 480 450 288 systems With 18 ZH01E
Double sides
SS3.691.552 ZH01D 177 542 97 20 systems
SS3.691.553 ZH01E 177 405 61 16 systems
SS3.691.547 ZH19A
SS3.691.549 ZH19A-1
177 482 6716 systems
19 installation
75 -120 conversion, Suitable
for convert chip; ZH19A-1 units
socket and printed plate are welded together.
SS3.691.548 ZH19B
Digitaldistribution
frame
Unit
SS3.691.549 ZH19B-1
177 482 67 16 systems Rotatable, 19 installation
Name Code Model Weight (g) Remarks
Stippling pliers U, 2,008,B MHT4095-008 169.2
Crimping pliers U, 2,480-483-484,Y YJQ-A 598
Dismantling sleeve U, 9,4,TT NE04A 119.4 Suit for MPX33-NE units
Name Code Model Specification Remarks
Crimping Pliers U,2,480-483-484,Y YJQ-A
Wire Stripping Pliers U 2 008 B MHT4095-008
Exchang Test Cord SS3.695.482 SM05B-1 L=3m
Test Cord SS3.695.484 SM05B-1 L=3m
Accessories
Digital Distribution Frame
SUNSEA TELECOMMUNICATIONS CO.,LTD.
ZH19 Unit provides 75 / 120 bidirectional conversion function and available in all kind of DDF equipment rooms.
ZH19 Unit
Brief
19 installation
Blocking-design, easy conversion and expansion
Lead-in/out cable at the same side, easy operation
75 : BNC connector plugs
120 : RJ45 connector plugs
YD/T 1437-2006 compliant performance
Features
ZH19D
Operating rate: 2 ~ 155 Mbps
Free bidirectional conversion between 75 dual coaxial cables and 100-120 twisted pairs
Supporting STP and UTP
75 :L9 connectors
120 : wiring terminals
YD/T 1437-2006 compliant performance
The 75 / 120 conversion connector provides 75 / 120 bidirectional conversion function and is applicable to
small- and medium-sized DDF equipment rooms.
75 /120 Balun
Features
Digital Distribution Frame
SUNSEA TELECOMMUNICATIONS CO.,LTD.
Ordering information
ZH04A
SpecificationName Ordering code Model
(L H D)Capacity Remarks
SS3.691.555 ZH19C 482X88X160 16 Back-fixingUnit
SS3.691.558 ZH19D 482X87.1X48 16 Front-fixing
Balun SS3.691.554 ZH04A 14x44.5
Brief
Insertion tool
SS02F1
SS02C3SS02C2
SS02B1
SS02B2
MPX112-SSMPX112-SS1
Brief
Due to the IDC modules, MPX112-SS distribution frame suitable for various exchanges, and its transmit impedance is
120 , providing function of dispatch, transit and test.
MPX112-SSMPX112-SS2
Digital Distribution Frame
SUNSEA TELECOMMUNICATIONS CO.,LTD.
MPX112-SS Digital Distribution Products
SS01F16 SS01B
SS01F16
Features
Steel or aluminum extrusion frame
Perfect cable routing management
With assembling structure, the double-sided frame can be installed without
making hole, and is convenient for frame combination and extension
With narrow structure, the single-sided frame can be installed back-to-back,
and is convenient for frame combination
Clear line identification
Features
Modularized design, the capacity can be deployed into 2-systems
IDC technology
Copper-alloy terminal tag with double-slot structure, is convenient
for multi-connection and online test
Envelope -structure terminal tag avoids the miscontact
Label holder with rotary structure, is easy to operate
Adopt patent technology, the frame can offer reliable grounding
protection without earthing module
Working rate 2Mbit/s
Transmit impedance 120
Insulation impedance 1000M , 100M (after high & low temperature test)
20M (after hot temperature test)
Dielectric strength 500V 45Hz 60Hz , 1min no breakdown or flying arc
500V (after high & low temperature test), 250V (after wet & hot test)
Cross talk 60dB (50KHz~3.1MHz)
Attenuation 0.4dB (50KHz~3.1MHz)
Return loss 18dB (50KHz~3.1MHz)
Connect resistance between contact points 7m ; after test, increment 3m
Connect resistance between termination points 3m ; after test, increment 2m
Disconnect tensile 25N (lead diameter 0.4mm~0.6mm)
Fire-retardant characteristics of plastic part compliant with Ul94 V0
Characteristics
Digital Distribution Frame
SUNSEA TELECOMMUNICATIONS CO.,LTD.
MPX112-SS Frame
120 Unit
Accessories
Ordering information
MPX112-SS Digital Distribution Products
Digital Distribution Frame
SUNSEA TELECOMMUNICATIONS CO.,LTD.
SpecificationName Code Model
H W D(mm)Configurable capacity
Remarks
2600 985 1160
with guardrailSS4.102.341 MPX112-SS1
2600 480 880
without guardrail
640 systems, with 40 SS01DDouble-sidedAluminum Extrusion frame.
SS4.102.342 MPX112-SS2 2600 300 300 256 systems, with 16 SS01B
SS4.102.343 MPX112-SS3 2000 300 300 192 systems, with 12 SS01B
SS4.102.344 MPX112-SS4 2200 300 300 224 systems, with 14 SS01B
Single side
SS4.102.345 MPX112-19A1 2600 750 300 480 systems, with 10 SS19A 19 single-sided frame
SS3.691.538 SS01F16 136 106 81 16 systems Suitable for 1#
SS3.691.539 SS01F16A 136 106 81 16 systems Suitable for 2#
SS3.691.540 SS01F16B 136 106 99 16 systems Suitable for steel rack
SS3.691.542 SS01F04 40 106 81 4 systems Suitable for 1#
SS3.691.543 SS01F24 200 106 81 24 systems Suitable for 1#
SS3.691.544 SS01F24A 200 106 81 24 systems Suitable for 2#
SS3.691.531 SS01B 125 141.8 129 16 systemsIDC module, double-slot,with earthing line
SS3.691.532 SS01C 125 141.8 92 16 systems
SS3.691.534 SS01C19 172 482 99 32 systems 19 installation
SS3.691.535 SS19A 132.5 482 75.5 48 systems 19 installation, rotatable
SS3.691.536 SS19B 125 141.8 129 48 systemsIDC module, double-slot,with earthing line
Digitaldistribution
frameFrame
SS3.691.537 SS01E 125 141.8 102 16 systems
Name Code Model Specification Remarks
Insertion Tool SS4.430.010 XD-B1With scissors.the lifetim e is more than twentythousand times.
SS3.695.584 SS02C1 Suitable for SS01B/SS01CConnection Plug
SS3.695.587 SS02F1 Suitable for SS01F16
Disconnection Plug SS3.695.586 SS02C3 Suitable for S01B/SS01C /SS01F16
SS3.695.581 SS02B1 L=3m Suitable for S01B/SS01C /SS01F16
SS3.695.582 SS02B2 L=3m Suitable for SS01B/SS01C
SS3.695.585 SS02C2 L=3m Suitable for SS01B/SS01CExchang Test Cord
SS3.695.588 SSS02F2 L=3m Suitable for SS01F16
Test Cord SS3.695.589 SS02F3 L=3m Suitable for SS01F16
SUNSEA TELECOMMUNICATIONS CO.,LTD.
No. 2008-01E
Printed In February,2008
Copyright 1994-2008: SUNSEA Telecommunications Co.,LTD.
Design and specification are subject to change without notice.
C