Dimmer for 110-240 V AC loads up to 150 W with RX 433.92 MHz, 2 wired inputs. MCU -DM150

Transcript of MCU-DM150 Dimmer manual

Page 1: MCU-DM150 Dimmer manual

Dimmer for 110-240 V AC loads up to150 W with RX 433.92 MHz, 2 wired inputs.

MCU -DM150

Page 2: MCU-DM150 Dimmer manual

MN

LMCU

-DM

150E

NV1

.1

Nexta Techcompany brand of Team srlvia G.Oberdan 90, 33074 Fontanafredda (PN) - ItalyPh. +39 0434 998682 Email: [email protected]: www.nexta-tech.com

1 1

Page 3: MCU-DM150 Dimmer manual

2

INDEX1 - PRODUCT FEATURES 1.1 - TECHNICAL DATA 1.2 - DESCRIPTION 1.3 - CONFIGURATION DEPENDING ON TYPE OF LAMP2 - ELECTRICAL CONNECTIONS 2.1 - THREE-WIRE CONNECTIONS 2.2 - FOUR-WIRE CONNECTIONS3 - USE OF THE CONTROL UNIT 3.1 - USE VIA RADIO 3.2 - USE VIA WIRE4 - CONTROL UNIT SETTINGS 4.1 - CONFIGURATION OF BUTTONS VIA WIRE 4.2 - FADE SETTING: GRADUAL SWITCH ON 4.3 - FADE SETTING: GRADUAL SWITCH OFF 4.4 - SETTING ADJUSTABLE MINIMUM BRIGHTNESS 4.5 - "SAVE" FUNCTION (BRIGHTNESS LEVEL AT SWITCH-ON) 4.6 - TWO-WIRE CONNECTIONS5 - RADIO PROGRAMMING6 - DELETION OF TRANSMITTERS

INDEX1 - PRODUCT FEATURES 1.1 - TECHNICAL DATA 1.2 - DESCRIPTION 1.3 - CONFIGURATION DEPENDING ON TYPE OF LAMP2 - ELECTRICAL CONNECTIONS 2.1 - THREE-WIRE CONNECTIONS 2.2 - FOUR-WIRE CONNECTIONS3 - USE OF THE CONTROL UNIT 3.1 - USE VIA WIRE4 - CONTROL UNIT SETTINGS 4.1 - CONFIGURATION OF BUTTONS VIA WIRE 4.2 - FADE SETTING: GRADUAL SWITCH ON 4.3 - FADE SETTING: GRADUAL SWITCH OFF 4.4 - SETTING ADJUSTABLE MINIMUM BRIGHTNESS 4.5 - "SAVE" FUNCTION (BRIGHTNESS LEVEL AT SWITCH-ON) 4.6 - TWO-WIRE CONNECTIONS

2

Page 4: MCU-DM150 Dimmer manual

1.1 TECHNICAL DATA

Mains 90-260 V AC230V Max 150W, 110V max 75Wdimmable lamps (example: dimmable LED, halogen)resistive load, AC motors,electronic transformers dimmable with trailing or leading edge100433.920mhz ISMIP20-20 +55 °C52x43x21 mm

Power supply OutputType of load: dimmable

N° programmable transmittersRadio frequencyProtection ratingOperating temperatureDimensions

1 - PRODUCT FEATURES

- Installation must be carried out only by qualified technicians in compliance with the electrical and safety standards in force.- All connections must be made with the power turned-off.- Use suitable cables.- Do not cut through the aerial (see picture 1.1b)- A suitably sized disconnection device must be set up on the electric power line that supplies the product.- Disposal of waste materials must fully respect local standards.

WARNINGS

43mm

21mm 52mmLed

Dip switches

Button

58mm

Pic.1.1a

Pic.1.1b Pic.1.1c

L

3 3

1.1 TECHNICAL DATA

Mains 90-260 V AC230V Max 150W, 110V max 75Wdimmable lamps (example: dimmable LED, halogen)resistive load, AC motors,electronic transformers dimmable with trailing or leading edge100433.920mhz ISMIP20-20 +55 °C52x43x21 mm

Power supply OutputType of load: dimmable

N° programmable transmittersRadio frequencyProtection ratingOperating temperatureDimensions

1 - PRODUCT FEATURES

- Installation must be carried out only by qualified technicians in compliance with the electrical and safety standards in force.- All connections must be made with the power turned-off.- Use suitable cables.- Do not cut through the aerial (see picture 1.1b)- A suitably sized disconnection device must be set up on the electric power line that supplies the product.- Disposal of waste materials must fully respect local standards.

WARNINGS

43mm

21mm 52mmLed

Dip switches

Button

58mm

Pic.1.1a

Pic.1.1b Pic.1.1c

Page 5: MCU-DM150 Dimmer manual

4

1.2 DESCRIPTIONElectronic control unit with dimmer function, for wireless and wired control of LED lights and resistive, inductive and capacitive loads (standard and electronic transformers) up to 150 W2 wired inputs that can be set, including a specific one-hour fade function.Wide-ranging and accurate dimmer function; fade on and off that can be set to between 0 and 10 seconds.The ISM (industrial, scientific and medical) radio frequency band guarantees a long range, even through walls and ceilings.Simple programming with dip-switches, reduced dimensions with breakable tabs for fixing with screws or for insertion into connection boxes 55 mm in diameter.

Pic.1.2a Pic.1.2b

Pic.1.2c Pic.1.2d Pic.1.2e

Pic.1.2fbefore after

LN

N

L

N

1.2 DESCRIPTIONElectronic control unit with dimmer function, for wireless and wired control of LED lights and resistive, inductive and capacitive loads (standard and electronic transformers) up to 150 W2 wired inputs that can be set, including a specific one-hour fade function.Wide-ranging and accurate dimmer function; fade on and off that can be set to between 0 and 10 seconds.The ISM (industrial, scientific and medical) radio frequency band guarantees a long range, even through walls and ceilings.Simple programming with dip-switches, reduced dimensions with breakable tabs for fixing with screws or for insertion into connection boxes 55 mm in diameter.

Pic.1.2a Pic.1.2b

Pic.1.2c Pic.1.2d Pic.1.2e

Pic.1.2fbefore after

LN

N

L

N

4

Page 6: MCU-DM150 Dimmer manual

1.3 CONFIGURATION DEPENDING ON TYPE OF LAMPThe product is supplied with default settings that can be adapted to the different types of load. However, depending on the type of connection (3/4 wires or 2 wires, see paragraph 2 and 4.6) and the manu-facturing characteristics of the loads connected, some settings are recommended to optimise dimming and its range.

WARNING: If dimming is less than excellent, or there are problems with the power supply to the lamp, it isrecommended that:- if a two-wire connection has been used, a three or four-wire connection should be made (paragraph 2.1 or 2.2). Some types of loads are not suitable for this connection because of their manufacturing characteristics.

RESISTIVE LIGHTS, INDUCTIVE LOADS AND ELECTRONIC TRANSFORMERS:To ensure that it operates well with all types of load, the product is supplied with a default adjustableminimum brightness.To enjoy the full dimming range with these types of loads whose characteristics mean they usually even support low brightness values, just follow the "adjustable minimum brightness" procedure in paragraph 4.4.

LED LAMPSThe following procedure is not necessary but may optimise the operation of some LED lamps with manufactu-ring characteristics that mean they do not accept low brightness values during switch-on and dimming.

WITH SAVE FUNCTION NOT ON (see paragraph 4.5)- Set the desired minimum intensity value accepted by the type of lamp with wired or radio commands- Set this value as "adjustable minimum brightness", see paragraph 4.4

WITH SAVE FUNCTION ON (see paragraph 4.5)WARNING: this set-up is not recommended with LED lamps that are not suitable if you want to be able to adjust low brightness values.- Set the desired minimum brightness value accepted by the type of lamp with wired or radio commands- Give an OFF command- Give an ON command and check that the intensity supplied is enough to turn the light on- If the light doesn't come on, adjust the dimmer at a higher level of intensityWARNING: the light is off but the load is powered, use the "dimmer UP" command- Try to turn the light on and off again- Once the minimum intensity value that the lamp accepts is identified, set this value as "adjustable minimum brightness", see paragraph 4.4

5 5

1.3 CONFIGURATION DEPENDING ON TYPE OF LAMPThe product is supplied with default settings that can be adapted to the different types of load. However, depending on the type of connection (3/4 wires or 2 wires, see paragraph 2 and 4.6) and the manu-facturing characteristics of the loads connected, some settings are recommended to optimise dimming and its range.

WARNING: If dimming is less than excellent, or there are problems with the power supply to the lamp, it isrecommended that:- if a two-wire connection has been used, a three or four-wire connection should be made (paragraph 2.1 or 2.2). Some types of loads are not suitable for this connection because of their manufacturing characteristics.

RESISTIVE LIGHTS, INDUCTIVE LOADS AND ELECTRONIC TRANSFORMERS:To ensure that it operates well with all types of load, the product is supplied with a default adjustableminimum brightness.To enjoy the full dimming range with these types of loads whose characteristics mean they usually even support low brightness values, just follow the "adjustable minimum brightness" procedure in paragraph 4.4.

LED LAMPSThe following procedure is not necessary but may optimise the operation of some LED lamps with manufactu-ring characteristics that mean they do not accept low brightness values during switch-on and dimming.

WITH SAVE FUNCTION NOT ON (see paragraph 4.5)- Set the desired minimum intensity value accepted by the type of lamp with wired or radio commands- Set this value as "adjustable minimum brightness", see paragraph 4.4

WITH SAVE FUNCTION ON (see paragraph 4.5)WARNING: this set-up is not recommended with LED lamps that are not suitable if you want to be able to adjust low brightness values.- Set the desired minimum brightness value accepted by the type of lamp with wired or radio commands- Give an OFF command- Give an ON command and check that the intensity supplied is enough to turn the light on- If the light doesn't come on, adjust the dimmer at a higher level of intensityWARNING: the light is off but the load is powered, use the "dimmer UP" command- Try to turn the light on and off again- Once the minimum intensity value that the lamp accepts is identified, set this value as "adjustable minimum brightness", see paragraph 4.4

Page 7: MCU-DM150 Dimmer manual

6

2.2 FOUR-WIRE CONNECTIONS

P1 P2

LN N/L

1 2 3 4 5 6 7

WARNING: multiple buttons or loads can be connected using parallel wiring.

Pic.2.2

2.1 THREE-WIRE CONNECTIONS

LN

P1 P2

N/L

230V max150W

230V max150W

1 2 3 4 5 6 7

WARNING: multiple buttons or loads can be connected using parallel wiring.

This is the standard connection. In fact with this type of wiring the control unit will always be powered,even with the load (e.g. bulb) disconnected.

As in the case of three-wire connections (paragraph 2.1), here again the control unit will always be powered. The neutral to the load will, however, be provided directly by the control unit itself.

This control unit is set up for different types of connection that allow greater flexibility to adapt to different system configurations. These differ in terms of the number of wires required to power the control unit and/or load (see also paragraph 4.6).

2 ELECTRICAL CONNECTIONS

Pic.2.1

2.2 FOUR-WIRE CONNECTIONS

P1 P2

LN N/L

1 2 3 4 5 6 7

WARNING: multiple buttons or loads can be connected using parallel wiring.

Pic.2.2

2.1 THREE-WIRE CONNECTIONS

LN

P1 P2

N/L

230V max150W

230V max150W

1 2 3 4 5 6 7

WARNING: multiple buttons or loads can be connected using parallel wiring.

This is the standard connection. In fact with this type of wiring the control unit will always be powered,even with the load (e.g. bulb) disconnected.

As in the case of three-wire connections (paragraph 2.1), here again the control unit will always be powered. The neutral to the load will, however, be provided directly by the control unit itself.

This control unit is set up for different types of connection that allow greater flexibility to adapt to different system configurations. These differ in terms of the number of wires required to power the control unit and/or load (see also paragraph 4.6).

2 ELECTRICAL CONNECTIONS

Pic.2.1

6

Page 8: MCU-DM150 Dimmer manual

7

3 USE OF THE CONTROL UNIT

-WARNING: the connected devices must be buttonsThe device is set up to accept commands via wire by button in terminals 3 and 4.Should you want to control the load only via radio, it is not necessary to connect these devices for the control unit to work properly.The behaviour of the different keys is shown in the following table.

WARNING: The behaviour of the inputs can be modified with the procedure shown in paragraph 4.1

3.1 USE VIA WIRE

LOADOFF

INPUT P1:short pressure

Load on Load off

Dimmer intensity up / Dimmer intensity down of load

INPUT P1:long pressure

Dimmer intensity upof load

INPUT P2:short pressure

Noaction

INPUT P2:long pressure

Noaction

LOADON

Soft Off 1 hr:gradually fades in an hourSoft Off 1 hr:gradually fades in an hour

7

3 USE OF THE CONTROL UNIT

To control the loads via radio you must have compatible transmitters and therefore must carry out the associa-tion procedure, see paragraph 5.The transmitter's command modes depend on the model of transmitter used. If the transmitter is of a generic type, its operation depends on the way it is programmed (see paragraph 5, table 5.2b).If the transmitter is multifunctional, refer to the transmitter manual, to the paragraph entitled "commands sent by the transmitter", bearing in mind that it is a "dimmer" device.

3.1 USE VIA RADIO

WARNING: the connected devices must be buttonsThe device is set up to accept commands via wire by button in terminals 3 and 4.Should you want to control the load only via radio, it is not necessary to connect these devices for the control unit to work properly.The behaviour of the different keys is shown in the following table.

WARNING: The behaviour of the inputs can be modified with the procedure shown in paragraph 4.1

3.2 USE VIA WIRE

LOADOFF

INPUT P1:short pressure

Load on Load off

Dimmer intensity up / Dimmer intensity down of load

INPUT P1:long pressure

Dimmer intensity upof load

INPUT P2:short pressure

Noaction

INPUT P2:long pressure

Noaction

LOADON

Soft Off 1 hr:gradually fades in an hourSoft Off 1 hr:gradually fades in an hour

7

Page 9: MCU-DM150 Dimmer manual

8

PROCEDURE:

STEP 1Position DIPs 1, 2, 3 and 4to OFF-ON-OFF-ON

DIP 1, 2, 3, 4=OFF ON OFF ON

STEP 2Press the button on thereceiver for a short time.

The LED comes onand stays on.

STEP 3Press the button on the receiver for a short time.

Count the number of flashes emitted by the LED:6 flashes = MODE 1, see table 4.1a3 flashes = MODE 2, see table 4.1b

SHORTPRESSURE

SHORTPRESSURE

STEP 4To change the setting, repeat the procedurefrom point 1; the control unit will alternatebetween 3 and 6 flashes.

NUMBER TYPE OFOF FLASH INPUT 6 Mode 1 3 Mode 2

!: the following procedure must be donewith turned-off load

Table 4.1a - Behaviour of keys in mode1LOADOFF

INPUT P1:short pressure

On ofload 1

INPUT P1:long pressure

DimmerIntensity Upof load 1

INPUT P2:short pressure

Noaction

INPUT P2:long pressure

Noaction

Off ofload 1

Dimmer intensity up / downof load 1Soft Off 1 hr:gradually fadesin an hourSoft Off 1 hr:gradually fadesin an hour

LOADON

Table 4.1b - Behaviour of keys in mode2LOADOFF

INPUT P1:short pressure

On ofload 1

INPUT P1:long pressure

Dimmerintensity Upof load 1

INPUT P2:short pressure

Noaction

Offload 1

INPUT P2:long pressure

Noaction

Dimmerintensity downof load 1

Dimmerintensity Upof load 1

Dimmerintensity Upof load 1

LOADON

Default: mode 1

This procedure is used to set up the operation of wired inputs "P1" and "P2".

PROCEDURE:

4.1 CONFIGURATION OF BUTTONS VIA WIRE

STEP 1Position DIPs 1, 2, 3 and 4to OFF-ON-OFF-ON

DIP 1, 2, 3, 4=OFF ON OFF ON

STEP 2Press the button on thereceiver for a short time.

The LED comes onand stays on.

STEP 3Press the button on the receiver for a short time.

Count the number of flashes emitted by the LED:6 flashes = MODE 1, see table 4.1a3 flashes = MODE 2, see table 4.1b

SHORTPRESSURE

SHORTPRESSURE

STEP 4To change the setting, repeat the procedurefrom point 1; the control unit will alternatebetween 3 and 6 flashes.

NUMBER TYPE OFOF FLASH INPUT 6 Mode 1 3 Mode 2

4 CONTROL UNIT SETTINGS

!: the following procedure must be donewith turned-off load

Table 4.1a - Behaviour of keys in mode1LOADOFF

INPUT P1:short pressure

On ofload 1

INPUT P1:long pressure

DimmerIntensity Upof load 1

INPUT P2:short pressure

Noaction

INPUT P2:long pressure

Noaction

Off ofload 1

Dimmer intensity up / downof load 1Soft Off 1 hr:gradually fadesin an hourSoft Off 1 hr:gradually fadesin an hour

LOADON

Table 4.1b - Behaviour of keys in mode2LOADOFF

INPUT P1:short pressure

On ofload 1

INPUT P1:long pressure

Dimmerintensity Upof load 1

INPUT P2:short pressure

Noaction

Offload 1

INPUT P2:long pressure

Noaction

Dimmerintensity downof load 1

Dimmerintensity Upof load 1

Dimmerintensity Upof load 1

LOADON

8

Page 10: MCU-DM150 Dimmer manual

Default: 0.5 secs

This procedure means you can set the duration of the switch-on time.

PROCEDURE:

4.2 FADE SETTING: GRADUAL SWITCH ON

STEP 1Position DIPs 1, 2, 3 and 4to ON-ON-OFF-ON.

DIP 1, 2, 3, 4=ON ON OFF ON

STEP 2Press the button on thereceiver for a short time.

The LED comes onand stays on.

SHORTPRESSURE

!: the following procedure must be donewith turned-off load

FLASHES SWITCH-ON TIME1 flash immediate ON2 flashes ON ~ 0,5s3 flashes ON ~ 2s4 flashes ON ~ 4s5 flashes ON ~ 10s

STEP 3Press the button on the receiver for a short timecount the number of flashes emitted by the LED:

SHORTPRESSURE

SHORT PRESSUREDURING THE FLASH

STEP 4Press the button for ashort time during theflash that correspondsto the function desiredto end the count

9 9

Default: 0.5 secs

This procedure means you can set the duration of the switch-on time.

PROCEDURE:

4.2 FADE SETTING: GRADUAL SWITCH ON

STEP 1Position DIPs 1, 2, 3 and 4to ON-ON-OFF-ON.

DIP 1, 2, 3, 4=ON ON OFF ON

STEP 2Press the button on thereceiver for a short time.

The LED comes onand stays on.

SHORTPRESSURE

!: the following procedure must be donewith turned-off load

FLASHES SWITCH-ON TIME1 flash immediate ON2 flashes ON ~ 0,5s3 flashes ON ~ 2s4 flashes ON ~ 4s5 flashes ON ~ 10s

STEP 3Press the button on the receiver for a short timecount the number of flashes emitted by the LED:

SHORTPRESSURE

SHORT PRESSUREDURING THE FLASH

STEP 4Press the button for ashort time during theflash that correspondsto the function desiredto end the count

Page 11: MCU-DM150 Dimmer manual

10

Default: 0.5 secs

This procedure means you can set the duration of the switch-off time.

PROCEDURE:

4.3 FADE SETTING: GRADUAL SWITCH OFF

STEP 1Position DIPs 1, 2, 3 and 4to ON-OFF-OFF-ON.

DIP 1, 2, 3, 4=ON OFF OFF ON

STEP 2Press the button on thereceiver for a short time.

The LED comes onand stays on.

SHORTPRESSURE

!: the following procedure must be donewith turned-off load

FLASHES SWITCH-OFF TIME1 flash immediate OFF2 flashes OFF ~ 0,5s3 flashes OFF ~ 2s4 flashes OFF ~ 4s5 flashes OFF ~ 10s

STEP 3Press the button on the receiver for a short timecount the number of flashes emitted by the LED:

SHORTPRESSURE

SHORT PRESSUREDURING THE FLASH

STEP 4Press the button for ashort time during theflash that correspondsto the function desiredto end the count

Default: 0.5 secs

This procedure means you can set the duration of the switch-off time.

PROCEDURE:

4.3 FADE SETTING: GRADUAL SWITCH OFF

STEP 1Position DIPs 1, 2, 3 and 4to ON-OFF-OFF-ON.

DIP 1, 2, 3, 4=ON OFF OFF ON

STEP 2Press the button on thereceiver for a short time.

The LED comes onand stays on.

SHORTPRESSURE

!: the following procedure must be donewith turned-off load

FLASHES SWITCH-OFF TIME1 flash immediate OFF2 flashes OFF ~ 0,5s3 flashes OFF ~ 2s4 flashes OFF ~ 4s5 flashes OFF ~ 10s

STEP 3Press the button on the receiver for a short timecount the number of flashes emitted by the LED:

SHORTPRESSURE

SHORT PRESSUREDURING THE FLASH

STEP 4Press the button for ashort time during theflash that correspondsto the function desiredto end the count

10

Page 12: MCU-DM150 Dimmer manual

This procedure allows you to set the minimum level of brightness at which it is possible to adjust the load.The minimum level of brightness accepted at switch-on and dimming depends on the type of load connected.

PROCEDURE:

4.4 SETTING ADJUSTABLE MINIMUM BRIGHTNESS

STEP 1Position DIPs 1, 2, 3 and 4to OFF-OFF-OFF-ON.

DIP 1, 2, 3, 4=OFF OFF OFF ON

STEP 2Press the button on thereceiver for a short time.

The LED comes onand stays on.

SHORTPRESSURE

STEP 3Set the desired minimum brightness

!: the following procedure must be donewith turned-off load

SHORTPRESSURE

STEP 4Press the button on thereceiver for a short time

The LED flashes 3 timesto confirm.

11 11

This procedure allows you to set the minimum level of brightness at which it is possible to adjust the load.The minimum level of brightness accepted at switch-on and dimming depends on the type of load connected.

PROCEDURE:

4.4 SETTING ADJUSTABLE MINIMUM BRIGHTNESS

STEP 1Position DIPs 1, 2, 3 and 4to OFF-OFF-OFF-ON.

DIP 1, 2, 3, 4=OFF OFF OFF ON

STEP 2Press the button on thereceiver for a short time.

The LED comes onand stays on.

SHORTPRESSURE

STEP 3Set the desired minimum brightness

!: the following procedure must be donewith turned-off load

SHORTPRESSURE

STEP 4Press the button on thereceiver for a short time

The LED flashes 3 timesto confirm.

Page 13: MCU-DM150 Dimmer manual

12

Default: save not on

WARNING: with LED lamps that do not accept low brightness values (typical of LED bulbs),it is not advisable to use the save function to avoid the light being turned-off when there is insufficient intensityto turn on the actual light.

PROCEDURE:

4.5 "SAVE" FUNCTION (BRIGHTNESS LEVEL AT SWITCH-ON)

STEP 1Position DIPs 1, 2, 3 and 4to OFF-ON-OFF-OFF.

DIP 1, 2, 3, 4=OFF ON OFF OFF.

STEP 2Press the button on thereceiver for a short time.

The LED comes onand stays on.

SHORTPRESSURE

!: the following procedure must be donewith turned-off load

STEP 3Press the button on the receiver for a short time

Count the number of flashes emitted by the LED:3 flashes= Last value set6 flashes= Maximum brightness

SHORTPRESSURE

STEP 4To change the setting, repeat the procedurefrom point 1;the control unit will alternate between 3 and 6 flashes.

NUMBER INTENSITYOF FLASH AT SWITCH-ON 3 Last value set6 Maximum brightness

Default: save not on

WARNING: with LED lamps that do not accept low brightness values (typical of LED bulbs),it is not advisable to use the save function to avoid the light being turned-off when there is insufficient intensityto turn on the actual light.

PROCEDURE:

4.5 "SAVE" FUNCTION (BRIGHTNESS LEVEL AT SWITCH-ON)

STEP 1Position DIPs 1, 2, 3 and 4to OFF-ON-OFF-OFF.

DIP 1, 2, 3, 4=OFF ON OFF OFF.

STEP 2Press the button on thereceiver for a short time.

The LED comes onand stays on.

SHORTPRESSURE

!: the following procedure must be donewith turned-off load

STEP 3Press the button on the receiver for a short time

Count the number of flashes emitted by the LED:3 flashes= Last value set6 flashes= Maximum brightness

SHORTPRESSURE

STEP 4To change the setting, repeat the procedurefrom point 1;the control unit will alternate between 3 and 6 flashes.

NUMBER INTENSITYOF FLASH AT SWITCH-ON 3 Last value set6 Maximum brightness

12

Page 14: MCU-DM150 Dimmer manual

Default: three-wire connections (see paragraph 2)

This procedure is used to set up the type of connection of the load. This kind of set up allow the device to adapt to the power supply in order to correct manage of the load.

PROCEDURE:

4.6 TWO-WIRE CONNECTIONS

STEP 1Position DIPs 1, 2, 3 and 4to OFF-OFF-OFF-OFF

DIP 1, 2, 3, 4=OFF OFF OFF OFF

!: the following procedure must be donewith turned-off load

STEP 2Press the button on thereceiver for a short time.

The LED comes onand stays on.

SHORTPRESSURE

STEP 3Press the button on the receiver for a short time.

Count the number of flashes emitted by the LED:3 flashes= three-wire connections. (see paragraph 2)6 flashes= two-wire connections (see picture 4.6)

SHORTPRESSURE

STEP 4to change the setting, repeat the procedure from point 1; the control unit will alternate between3 or 6 flashes.

NUMBER OF TYPE OF FLASHES CONNECTION3 three-wire connections (see paragraph 2)6 two-wire connections (see picture 4.6)