Matrix Applied TechnologiesFloating Suction Lines & Skimmers
Articulated lines
When tank height is greater than tank diameter, a single arm suction line will not reach maximum liquid level height. In this case, a two-arm or articulated suction line is required. See below. A similar articulated confi gura-tion can be used for skimmer lines.
Skimmers
These are designed to skim off a layer of hydrocarbon liquid fl oating on top of water. Essentially, a skimmer is designed to remove the top layer of a 2 phase liquid stored in a tank.
Line sizes are usually 3” or 4” although Matrix Applied Technologies can make them in larger sizes. The minimum line diameter is 3”. Pontoons are designed to fl oat on their centerline at the lowest S.G. tank product. The skimmer plate is located an adjustable distance below this.
Over thirty years of excellence.
Safety. Integrity. Positive relationships. Stewardship. Community involvement. Delivering the best. These core values have forged our reputation for excellence.
S T R E N G T H
F L EX I B I L I T Y
PARTNERSHIP
Matrix Applied Technologies is a subsid-iary of Matrix Service Company (Nasdaq: MTRX), a top-tier engineering, construction and maintenance company that, through our family of brands, designs, builds and maintains infrastructure critical to North America’s energy, power and industrial mar-kets. Matrix Applied Technologies designs,
develops and markets precision engineered, premier products and technologies for the energy and industrial markets. The team combines innovative engineering and design with cutting-edge manufacturing processes to bring reliable, innovative and cost-eff ec-tive products to customers worldwide.
S T R E N G T H
FLEX IB I L I TY
PARTNERSHIP
Suction Line
Matrix Applied Technologies Level Indicator:
This consists of a cable connected to the suction line. This cable is connected to a weight running up and down guide rods on the outside of the tank shell to give visual indication that the suction line is operating correctly. It also gives a quick visual indication of the suction line position.
In the case of a fl oating roof, it is impossible to see if a fl oating suction line is operating correctly or not. It is a good idea, therefore, to fi t a level indicator when a suction line operates beneath a fl oating roof.
For level indicators beneath a steel fl oating roof, a ½” pipe is welded vertically into the pontoon and the cable passes through this to a pulley at the top corner of the tank. This arrangement can be seen in the roller type suction line illustration below.
For aluminium and stainless steel IFRs, a vertical cable guide pipe can be built into the IFR.
Matrix Applied TechnologiesFloating Suction Lines & Skimmers
Matrix Applied Technologies SwingMaster joints are available in 3” to 44” diameters. 3” lines use a Matrix Applied Technologies drain joint.
Matrix Applied Technologies CAN HELP SOLVE YOUR TANK DESIGN and MAINTENANCE PROBLEMS
Both the Matrix Applied Technologies Heavy Duty Pontoon Aluminium Internal Floating Roof (IFR) and Full Contact fully welded Honeycomb panel IFR have been designed for long, maintenance free service.
Pontoon IFRs are available as all aluminium, all stainless steel and as a combination (hybrid) of both these two options.
IFRs can be cable or chain suspended from steel fi xed roofs or from Matrix Applied Technologies geodesic dome roofs.
Matrix Applied Technologies manufactures the following quality products for the abovegroundstorage tank industry:
• Aluminium Geodesic FlowDome™ Roofs• Aluminium Pontoon Internal Floating Roofs• Stainless Steel Pontoon Floating Roofs• Aluminium Full Contact IFRs• Floating Roof Seal Systems• Specialized Floating Suction Lines• SwingMaster Swing Joints• Floating Roof Drain Systems
Matrix Applied TechnologiesFloating Suction Lines & Skimmers
Matrix Applied Technologies is a global leader in the design and manufacture of fl oating suction lines and skimmers for use worldwide. Suction lines are commonly used for aviation facility Jet-A1 and Avgas tanks. Suction lines can be used in power plants, crude oil collection tanks or anywhere the quality of the product to exit the tank is an issue.
Matrix Applied Technologies can custom design fl oating suction lines and skimmers for various tank confi gura-tions. Lines are either installed in fi xed roof tanks or can be located below internal or external fl oating roofs.
Suspended type suction line
Sample lines
Sample lines can be provided on the main suction arm for fuel sampling. Matrix Applied Technologies can provide ¾” or 1” dia. sample lines. Typically, sample points are located at the center of lower third, middle third & upper third of the tank liquid level.
Roller type suction line
Roller type fl oating suction line. This suction line type is fi tted with a roller. The roller runs along the steel fl oating roof underside. No special track is required, the roller can negotiate plate overlaps.
The same suction line can operate beneath an aluminium or stainless steel IFR and, in this case, a track must be added beneath the IFR for the roller to run on. As an IFR manufacturer, Matrix Applied Technologies can design an appropriate suction line track and provide extra buoyancy for aluminium or stainless steel IFRs when necessary.
There are 2 main suction line types:• Suspended type. This type, pictured above, is most commonly used for fi xed roof tanks• Roller type. This type is for use beneath a steel or aluminium fl oating roof.Available line diameters: 3” to 44”.
Matrix Applied Technologies Level Indicator:
This consists of a cable connected to the suction line. This cable is connected to a weight running up and down guide rods on the outside of the tank shell to give visual indication that the suction line is operating correctly. It also gives a quick visual indication of the suction line position.
In the case of a fl oating roof, it is impossible to see if a fl oating suction line is operating correctly or not. It is a good idea, therefore, to fi t a level indicator when a suction line operates beneath a fl oating roof.
For level indicators beneath a steel fl oating roof, a ½” pipe is welded vertically into the pontoon and the cable passes through this to a pulley at the top corner of the tank. This arrangement can be seen in the roller type suction line illustration below.
For aluminium and stainless steel IFRs, a vertical cable guide pipe can be built into the IFR.
Matrix Applied TechnologiesFloating Suction Lines & Skimmers
Matrix Applied Technologies SwingMaster joints are available in 3” to 44” diameters. 3” lines use a Matrix Applied Technologies drain joint.
Matrix Applied Technologies CAN HELP SOLVE YOUR TANK DESIGN and MAINTENANCE PROBLEMS
Both the Matrix Applied Technologies Heavy Duty Pontoon Aluminium Internal Floating Roof (IFR) and Full Contact fully welded Honeycomb panel IFR have been designed for long, maintenance free service.
Pontoon IFRs are available as all aluminium, all stainless steel and as a combination (hybrid) of both these two options.
IFRs can be cable or chain suspended from steel fi xed roofs or from Matrix Applied Technologies geodesic dome roofs.
Matrix Applied Technologies manufactures the following quality products for the abovegroundstorage tank industry:
• Aluminium Geodesic FlowDome™ Roofs• Aluminium Pontoon Internal Floating Roofs• Stainless Steel Pontoon Floating Roofs• Aluminium Full Contact IFRs• Floating Roof Seal Systems• Specialized Floating Suction Lines• SwingMaster Swing Joints• Floating Roof Drain Systems
Matrix Applied TechnologiesFloating Suction Lines & Skimmers
Matrix Applied Technologies is a global leader in the design and manufacture of fl oating suction lines and skimmers for use worldwide. Suction lines are commonly used for aviation facility Jet-A1 and Avgas tanks. Suction lines can be used in power plants, crude oil collection tanks or anywhere the quality of the product to exit the tank is an issue.
Matrix Applied Technologies can custom design fl oating suction lines and skimmers for various tank confi gura-tions. Lines are either installed in fi xed roof tanks or can be located below internal or external fl oating roofs.
Suspended type suction line
Sample lines
Sample lines can be provided on the main suction arm for fuel sampling. Matrix Applied Technologies can provide ¾” or 1” dia. sample lines. Typically, sample points are located at the center of lower third, middle third & upper third of the tank liquid level.
Roller type suction line
Roller type fl oating suction line. This suction line type is fi tted with a roller. The roller runs along the steel fl oating roof underside. No special track is required, the roller can negotiate plate overlaps.
The same suction line can operate beneath an aluminium or stainless steel IFR and, in this case, a track must be added beneath the IFR for the roller to run on. As an IFR manufacturer, Matrix Applied Technologies can design an appropriate suction line track and provide extra buoyancy for aluminium or stainless steel IFRs when necessary.
There are 2 main suction line types:• Suspended type. This type, pictured above, is most commonly used for fi xed roof tanks• Roller type. This type is for use beneath a steel or aluminium fl oating roof.Available line diameters: 3” to 44”.
matrixappliedtech.com
Matrix Applied TechnologiesFloating Suction Lines & Skimmers
Articulated lines
When tank height is greater than tank diameter, a single arm suction line will not reach maximum liquid level height. In this case, a two-arm or articulated suction line is required. See below. A similar articulated confi gura-tion can be used for skimmer lines.
Skimmers
These are designed to skim off a layer of hydrocarbon liquid fl oating on top of water. Essentially, a skimmer is designed to remove the top layer of a 2 phase liquid stored in a tank.
Line sizes are usually 3” or 4” although Matrix Applied Technologies can make them in larger sizes. The minimum line diameter is 3”. Pontoons are designed to fl oat on their centerline at the lowest S.G. tank product. The skimmer plate is located an adjustable distance below this.
Over thirty years of excellence.
Safety. Integrity. Positive relationships. Stewardship. Community involvement. Delivering the best. These core values have forged our reputation for excellence.
S T R E N G T H
F L EX I B I L I T Y
PARTNERSHIP
Matrix Applied Technologies is a subsid-iary of Matrix Service Company (Nasdaq: MTRX), a top-tier engineering, construction and maintenance company that, through our family of brands, designs, builds and maintains infrastructure critical to North America’s energy, power and industrial mar-kets. Matrix Applied Technologies designs,
develops and markets precision engineered, premier products and technologies for the energy and industrial markets. The team combines innovative engineering and design with cutting-edge manufacturing processes to bring reliable, innovative and cost-eff ec-tive products to customers worldwide.
S T R E N G T H
FLEX IB I L I TY
PARTNERSHIP
Suction Line
Matrix Applied Technologies SwingMaster central type swing joints are the ideal choice for floating suction lines. Constructed in rugged cast ductile iron with plain Ni-Resist bearings (copper free), all SwingMaster joints are sealed with internal Viton O-Rings. Matrix Applied Technologies SwingMaster swing joints are internally and externally epoxy painted for Jet A1 ser-vice using Interline 850 paint. 100% cast stainless steel joints are available to special order. SwingMaster joints are available in 4” to 36” size. Larger sizes are available on application. SwingMaster standard flanges are ANSI 150# flat face.
SwingMaster Swing Jointsfor Floating Suction Lines
matrixappliedtech.com1-866-367-6879
32” stainless steel SwingMaster
INCH:minimum opening minimum opening
Size in tank for in tank forinch SwingMaster entry SwingMaster entry
4 230 x 320 or Ø380 9.25" x 12.5" or 15"Ø6 290 x 380 or Ø480 11.5"x 15" or 19"Ø8 360 x 470 or Ø590 14" x 18.5" or 23.5"Ø
10 420 x 560 or Ø700 16.5" x 22" or 27.5"Ø12 500 x 680 or Ø850 20" x 27" or 33.5"Ø14 550 x 740 or Ø930 22" x 29" or 37"Ø16 620 x 820 or Ø1030 24.5" x 32.5" or 40.5"Ø18 650 x 910 or Ø1120 26" x 36" or 44"Ø20 710 x 950 or Ø1190 28" x 37.5" or 47"Ø24 830 x 1130 or Ø1400 33" x 44.5" or 55"Ø26 900 x 1200 or Ø1450 36" x 48" or 58"Ø30 990 x 1290 or Ø1630 39" x 51" or 64"Ø32 1060 x 1380 orØ1800 42" x 55" or 71"Ø36 1200 x 1520 or Ø2000 48" x 60" or 79"Ø
METRIC:
matrixappliedtech.com1-866-367-6879
Matrix Applied Technologies tank products include:
• Aluminium and stainless IFRs• Geodesic dome roofs• Floating suction lines and skimmers
• SwingMaster swing joints 4”-36”• Floating roof tank primary and secondary seals• Floating roof tank drain systems
SwingMaster Swing Jointsfor Floating Suction Lines
flange flange flange lifting lug RotationSize tapped holes drilled holes bolt circle tapped holes Torque Weightinch A B C D L N O mm P.C.D. mm E kg-m kg
4 447 180 - 229 295 4 x 5/8" UNC 4+ 8 x 19.0dia 190.50 - 5 516 536 232 393 279 371 4 x 3/4" UNC 4+ 8 x 22.4dia 241.30 4 x M10 6.0 668 658 281 482 343 449 4 x 3/4" UNC 4+ 8 x 22.4dia 298.45 4 x M12 12.0 11410 824 338 592 406 538 8 x 7/8" UNC 4+12 x 25.4dia 361.95 4 x M16 15.0 19012 1007 417 707 483 652 8 x 7/8" UNC 4+12 x 25.4dia 431.80 4 x M16 18.5 29614 1083 452 779 534 709 8 x 1" UNC 4+12 x 28.6dia 476.20 4 x M16 27.9 34916 1224 506 885 597 783 8 x 1" UNC 8+16 x 28.6dia 539.70 4 x M16 31.9 49518 1377 570 996 635 881 8 x 1⅛" UNC 8+16 x 31.8dia 577.90 4 x M16 35.9 63820 1410 614 1041 699 940 12 x 1⅛" UNC 8+20 x 31.8dia 635.00 4 x M20 39.9 83824 1714 715 1229 813 1090 12 x 1¼" UNC 8+20 x 35.0dia 749.30 4 x M24 47.9 124126 1932 759 1323 786 1163 16 x 3/4" UNC 20+36 x 22.35dia. 744.47 2 x M24 50.0 128530 2078 832 1460 984 1285 16 x 1¼" UNC 12+28 x 35 dia 914.40 2 x M30 64.0 194432 2226 888 1600 1060 1376 16 x 1 1/3"UNC 12+28 x 41dia 977.90 2 x M30 80.0 220036 2576 984 1780 1057 1513 28 x 7/8" UNC 16+44x25.4dia. 1009.70 2 x M30 105.0 3672
Note: 4" SwingMaster joints are in 316 stainless steel as standard.flange flange flange lifting lug Rotation
Size tapped holes drilled holes bolt circle tapped holes Torque Weightinch A B C D L N O inch P.C.D.inch E ft-lbf lb
4 17.6 7.087 - 9.0 11.61 4 x 5/8" UNC 4+ 8 x 5/8"dia 7.50 - 36 1126 21.1 9.134 15.47 10.98 14.61 4 x 3/4" UNC 4+ 8 x 7/8"dia 9.50 4 x M10 43 1458 25.9 11.06 18.98 13.5 17.68 4 x 3/4" UNC 4+ 8 x 7/8"dia 11.75 4 x M12 87 25110 32.4 13.31 23.31 16.0 21.18 8 x 7/8" UNC 4+12 x 1"dia 14.25 4 x M16 108 41812 39.6 16.42 27.83 19.0 25.67 8 x 7/8" UNC 4+12 x 1"dia 17.00 4 x M16 133 65114 42.6 17.8 30.67 21.0 27.91 8 x 1" UNC 4+12 x 1⅛"dia 18.75 4 x M16 201 76816 48.2 19.92 34.84 23.5 30.83 8 x 1" UNC 8+16 x 1⅛"dia 21.25 4 x M16 230 108918 54.2 22.44 39.21 25.0 34.69 8 x 1⅛" UNC 8+16 x 1¼"dia 22.75 4 x M20 259 140420 55.5 24.17 40.98 27.5 37.01 12 x 1⅛" UNC 8+20 x 1¼"dia 25.00 4 x M20 288 184424 67.5 28.15 48.39 32.0 42.91 12 x 1¼" UNC 8+20 x 1⅜"dia 29.50 4 x M24 345 273026 76.1 29.88 52.09 30.9 45.79 16 x 3/4" UNC 12+20 x 7/8"dia. 29.31 2 x M24 361 282730 81.8 32.76 57.48 38.7 50.59 16 x 1¼" UNC 12+28 x 1⅜"dia 36.00 2 x M30 462 427732 87.6 34.96 62.99 41.8 54.17 16 x 1 1/3"UNC 12+28 x 1 5/8"dia 38.50 2 x M30 577 484036 101 38.74 70.08 41.6 59.57 28 x 7/8" UNC 16+44 x 1"dia 39.75 2 x M30 758 8078
DIMENSION mm
DIMENSION inch
METRIC:
INCH:
MAT
ERIA
L LI
STSP
ECIF
ICAT
ION
DES
CRIP
TIO
NQ
TYIT
EMPA
RT
SS30
4SH
EAVE
CO
VER
11
IP10
1C.
S./G
ALV.
SHEA
VE Ø
360
12
IP10
2C.
S./G
ALV.
SHEA
VE Ø
150
23
IP10
3SS
304
SHEA
VE B
ASE
14
IP10
4SS
304
SHEA
VE P
IN3
5IP
105
SS30
4Ø
2.3
R-P
IN6
6
SS30
4M
12X2
8X1.
5mm
FL
AT W
ASH
ER6
7
SS30
4M
10 F
LAT
WAS
HER
48
SS
304
3/8"
N
UT
49
THIS
DO
CUM
ENT
AND
THE
WO
RKS
AND/
OR
INFO
RMAT
ION
CON
TAIN
EDTH
EREI
N AR
E TH
E CO
NFID
ENTI
ALAN
D PR
OPR
IETA
RY P
ROPE
RTY
OF
MA
TRIX
APP
LIED
TEC
HN
OLO
GIE
SAN
D SH
ALL
BE U
SED
ONL
Y FO
R TH
EIN
TEN
DED
PURP
OSE
AND
PRO
JECT
.IT
MAY
NOT
BE
COPI
ED IN
WHO
LEO
R IN
PAR
T. P
ARTS
MAY
NOT
BE
FABR
ICAT
ED F
ROM
THE
DO
CUM
ENT,
AND
THE
INFO
RMAT
ION
THER
EIN
MAY
NO
T BE
DIV
ULGE
D W
ITHO
UTM
ATR
IX A
PPLI
ED T
ECH
NO
LOG
IES
EXPR
ESS
WRI
TTEN
PER
MIS
SION
.
CUST
OM
ER:
LOC
ATIO
N:
DRA
WN
BY DAT
E
JOB
No.
CHEC
KED
BY PAPE
RSI
ZE
TAN
KD
IA.
TAN
KH
T.T
ANK
No.
DRA
WIN
G T
ITLE
DRA
WIN
G N
UM
BER
REV.
DET
AIL
SBY
DAT
ER
EV.
STAN
DAR
DSY
DN
EY, A
UST
RAL
IA
A3 IP10
00
LE
VEL
IND
ICAT
OR
SH
EAVE
ASS
EMBL
Y
DA
TE
NO
TES
:1.
UN
LESS
OTH
ERW
ISE
STAT
ED A
LL D
IMEN
SIO
NS
IN M
ILLI
MET
RES
.FO
R IN
FORM
ATIO
N
524
403
333
170
R
340
430
140
(42)
TAN
K R
OO
F CU
T-O
UT
TEM
PLAT
E
1
3
210
8C
UT-
OU
T ST
ART
4
56
7
5TY
P
2 89
56
7
204 6
VIE
W-
A
ENLA
RG
ED
DE
TAIL
VIE
W -
B
ENLA
RG
ED
DET
AIL
VIE
W -
C
DET
AIL
VIE
W -
D
ENLA
RG
ED
A
DET
AIL
- B
DET
AIL
- C
MAT
ERIA
L LI
STSP
ECIF
ICAT
ION
DES
CRIP
TIO
NQ
TYIT
EMPA
RTCS
/ G
ALV
. / S
S304
SH
EAV
E A
SSEM
BLY
11
IP10
0CS
SUPP
OR
T PL
ATE
22
IP20
1ASS
304
LEVE
L IN
DIC
ATO
R P
LATE
13
IP20
1BSS
304
GU
IDE
RO
D
24
IP20
1CSS
304
LIFT
ING
STU
D1
5IP
201D
SS30
4 L
EVEL
IN
DIC
ATO
R C
ABLE
ASS
EMBL
Y1
6IP
202
HD
GW
EIG
HT
27
CSS
126
SS30
4M
12 H
EX N
UT
28
SS
304
3/16
" W
IRE
RO
PE G
RIP
39
SS
304
3/16
" TH
IMBL
E1
10
SS30
48m
m D
-SH
ACKL
E1
11
SS30
43/
8" U
NC
x 1.
5" H
EX B
OLT
212
SS
304
3/8"
UN
C N
UT
213
DET
AIL-
D
HL
HL
L L
L L
THIS
DO
CUM
ENT
AND
THE
WO
RKS
AND/
OR
INFO
RMAT
ION
CON
TAIN
EDTH
EREI
N AR
E TH
E CO
NFID
ENTI
ALAN
D PR
OPR
IETA
RY P
ROPE
RTY
OF
MA
TRIX
APP
LIED
TEC
HN
OLO
GIE
SAN
D SH
ALL
BE U
SED
ONL
Y FO
R TH
EIN
TEN
DED
PURP
OSE
AND
PRO
JECT
.IT
MAY
NOT
BE
COPI
ED IN
WHO
LEO
R IN
PAR
T. P
ARTS
MAY
NOT
BE
FABR
ICAT
ED F
ROM
THE
DO
CUM
ENT,
AND
THE
INFO
RMAT
ION
THER
EIN
MAY
NO
T BE
DIV
ULGE
D W
ITHO
UTM
ATR
IX A
PPLI
ED T
ECH
NO
LOG
IES
EXPR
ESS
WRI
TTEN
PER
MIS
SION
.
CUST
OM
ER:
LOC
ATIO
N:
DRA
WN
BY DAT
E
JOB
No.
CHEC
KED
BY PAPE
RSI
ZE
TAN
KD
IA.
TAN
KH
T.T
ANK
No.
DRA
WIN
G T
ITLE
DRA
WIN
G N
UM
BER
REV.
DET
AIL
SBY
DAT
ER
EV.
A3
LEVE
L IN
DICA
TOR
IP20
00
DA
TE
NO
TES
:1.
UN
LESS
OTH
ERW
ISE
STAT
ED A
LL D
IMEN
SIO
NS
IN M
ILLI
MET
RES
.
TAN
K SH
ELL
(OU
TSID
E )
TAN
K SH
ELL
(OU
TSID
E )
TAN
K RO
OF
430
140
160
400
200
FOR
INFO
RMAT
ION
TAN
K
FLO
OR
13502500
160
5TY
P
CON
NEC
T TO
SU
CTIO
N P
IPE
LUG
(35°
)
6
2 375 4
8
1213
5TY
P
(1948)LE
VEL
IND
ICAT
ING
M
ARKS
ON
TAN
K BY
CU
STO
MER
9
611
10
1
SEC
TIO
N A
-A
ENLA
RG
ED
A
A
MAT
ERIA
L LI
STSP
ECIF
ICAT
ION
DES
CRIP
TIO
NQ
TYIT
EMPA
RT
SS30
4SH
EAVE
BA
SE
11
IP10
4EC.
S./G
ALV.
SHEA
VE Ø
360
12
IP10
2ESS
316
SHEA
VE P
IN2
3IP
105
SS30
4Ø
2.3
R-P
IN4
4
SS30
4M
12 F
LAT
WA
SHER
45
C.
S./G
ALV.
SHEA
VE Ø
150
26
IP10
3SS
304
3/8"
FLA
T W
ASH
ER4
7
SS30
4SH
EAVE
CO
VER
18
IP10
1ESS
304
3/8"
UN
C N
UT
49
SS
304
& A
LEN
COD
ER1
10
EN
COD
ER C
OU
PLIN
G
111
IP11
7SS
316
SHEA
VE P
IN Ø
15 x
73m
m L
G1
12IP
105E
BRO
NZE
M12
x40x
3mm
FL
AT W
ASH
ER2
13IP
113
ALM
OU
NTI
NG
CAP
114
IP11
2SS
304
M6x
12 S
OCK
ET H
D C
AP
SCR
EW7
15
SS30
4KE
Y 4x
4x25
116
IP11
5SS
304
KEY
3x3x
251
17IP
116
THIS
DO
CUM
ENT
AND
THE
WO
RKS
AND/
OR
INFO
RMAT
ION
CON
TAIN
EDTH
EREI
N AR
E TH
E CO
NFID
ENTI
ALAN
D PR
OPR
IETA
RY P
ROPE
RTY
OF
MA
TRIX
APP
LIED
TEC
HN
OLO
GIE
SAN
D SH
ALL
BE U
SED
ONL
Y FO
R TH
EIN
TEN
DED
PURP
OSE
AND
PRO
JECT
.IT
MAY
NOT
BE
COPI
ED IN
WHO
LEO
R IN
PAR
T. P
ARTS
MAY
NOT
BE
FABR
ICAT
ED F
ROM
THE
DO
CUM
ENT,
AND
THE
INFO
RMAT
ION
THER
EIN
MAY
NO
T BE
DIV
ULGE
D W
ITHO
UTM
ATR
IX A
PPLI
ED T
ECH
NO
LOG
IES
EXPR
ESS
WRI
TTEN
PER
MIS
SION
.
CUST
OM
ER:
LOC
ATIO
N:
DRA
WN
BY DAT
E
JOB
No.
CHEC
KED
BY PAPE
RSI
ZE
TAN
KD
IA.
TAN
KH
T.T
ANK
No.
DRA
WIN
G T
ITLE
DRA
WIN
G N
UM
BER
REV.
DET
AIL
SBY
DAT
ER
EV.
STAN
DAR
DSY
DN
EY, A
UST
RAL
IAA3 IP
211
0
LEVE
L IN
DIC
ATO
RPU
LLEY
WIT
H S
ENSO
R
DA
TE
NO
TES
:1.
UN
LESS
OTH
ERW
ISE
STAT
ED A
LL D
IMEN
SIO
NS
IN M
ILLI
MET
RES
.
204
10
82
9 715
1411
1213
4 3 5
615
529
1
140
430
42
185
100
90204
1
TAN
K R
OO
F CU
T-O
UT
TEM
PLAT
E
108
CUT-
OU
T ST
ART
Ø11
.2m
m C
ABLE
, 9-C
OR
EST
AN
DAR
D L
ENG
TH 2
050
mm
,CO
NN
ECT
TO J
UN
CTIO
N B
OX
AND
TH
EN T
O P
LC C
ON
TRO
LLER
17
16
FOR
INFO
RMAT
ION
VIE
W-
A
ENLA
RG
ED
DET
AIL
VIE
W -
B
ENLA
RG
ED
DET
AIL
VIE
W -
C
DET
AIL
VIE
W -
D
ENLA
RG
ED
A
DET
AIL
- B
DET
AIL
- C
MAT
ERIA
L LI
STSP
ECIF
ICAT
ION
DES
CRIP
TIO
NQ
TYIT
EMPA
RTCS
/ G
ALV
. / S
S304
SH
EAV
E A
SSEM
BLY
11
IP10
0CS
/SS3
04FL
OO
R S
HEA
VE2
2IP
106
CSSU
PPO
RT
PLAT
E 2
3IP
201A
SS30
4LE
VEL
IND
ICAT
OR
PLA
TE1
4IP
201B
SS30
4G
UID
E R
OD
2
5IP
201C
SS30
4LI
FTIN
G S
TUD
16
IP20
1DSS
304
LEV
EL I
ND
ICAT
OR
CAB
LE A
SSEM
BLY
17
IP20
2H
DG
WEI
GH
T2
8C
SS12
6SS
304
M12
HEX
NU
T2
9
SS30
43/
16"
THIM
BLE
110
SS
304
8mm
D-S
HAC
KLE
111
SS
304
3/8"
UN
C x
1.5"
HEX
BO
LT2
12
SS30
43/
8" U
NC
NU
T2
13
SS30
43/
16"
WIR
E R
OPE
GRI
P3
14
DET
AIL-
D
HL
HL
L L
L L
CUST
OM
ER:
LOC
ATIO
N:
DRA
WN
BY DAT
E
JOB
No.
CHEC
KED
BY PAPE
RSI
ZE
TAN
KD
IA.
TAN
KH
T.T
ANK
No.
DRA
WIN
G T
ITLE
DRA
WIN
G N
UM
BER
REV.
DET
AIL
SBY
DAT
ER
EV.
A3 IP22
00
LEVE
L IN
DIC
ATO
R AS
SEM
BLY
(BEN
EATH
FLO
ATIN
G R
OO
F TY
PE)
DA
TE
THIS
DO
CUM
ENT
AND
THE
WO
RKS
AND/
OR
INFO
RMAT
ION
CON
TAIN
EDTH
EREI
N AR
E TH
E CO
NFID
ENTI
ALAN
D PR
OPR
IETA
RY P
ROPE
RTY
OF
MA
TRIX
APP
LIED
TEC
HN
OLO
GIE
SAN
D SH
ALL
BE U
SED
ONL
Y FO
R TH
EIN
TEN
DED
PURP
OSE
AND
PRO
JECT
.IT
MAY
NOT
BE
C OPI
ED IN
WHO
LEO
R IN
PAR
T. P
ARTS
MAY
NOT
BE
FABR
ICAT
ED F
ROM
THE
DO
CUM
ENT,
AND
THE
INFO
RMAT
ION
THER
EIN
MAY
NO
T BE
DIV
ULGE
D W
ITHO
UTM
ATR
IX A
PPLI
ED T
ECH
NO
LOG
IES
EXPR
ESS
WRI
TTEN
PER
MIS
SION
.
NO
TES
:1.
UN
LESS
OTH
ERW
ISE
STAT
ED A
LL D
IMEN
SIO
NS
IN M
ILLI
MET
RES.
TAN
K SH
ELL
(OU
TSID
E )
TAN
K SH
ELL
(OU
TSID
E )
TAN
K R
OO
F
430
140
160
400
200
FOR
INFO
RMAT
ION
2500
5TY
P
7
3 486 5
9
1213
5TY
P
(1948)
LEVE
L IN
DIC
ATI
NG
M
ARKS
ON
TA
NK
BY C
UST
OM
ER 7
1
141011
1/2"
PIP
E
CABL
E PA
SSES
TH
ROU
GH
THE
FLO
ATIN
G R
OO
F.
TAN
K FL
OO
R
CON
NEC
T TO
SUCT
ION
PIP
E LU
G
2
FLO
ATIN
G R
OO
FPO
NTO
ON
TYP
E
2
VIE
W-
A
ENLA
RG
ED
DE
TAIL
VIE
W -
C
EN
LAR
GE
D
DE
TAIL
VIE
W -
D
ENLA
RG
ED
A
MATE
RIA
L LI
STSP
ECIF
ICAT
ION
DES
CRIP
TIO
NQ
TYIT
EMPA
RTH
DG
/ S
S304
SH
EAV
E A
SSEM
BLY
11
IP40
1SS
304
SUPP
OR
T PL
ATE
22
IP40
2ASS
304
LEVE
L IN
DIC
ATO
R P
LATE
13
IP40
2BSS
304
LIFT
ING
STU
D1
4IP
201D
GA
LV.
WEI
GH
T2
5C
SS12
6SS
304
LEV
EL I
ND
ICAT
OR
CAB
LE
16
IP20
2SS
304
GU
IDE
CAB
LE
27
IP41
0SS
304
M12
HEX
NU
T 2
8
SS30
43/
16"
WIR
E R
OPE
GRI
P9
9
SS30
48
mm
D-S
HAC
KLE
110
SS
304
3/16
" TH
IMBL
E3
11
SS30
43_
8 IN
CH E
YEBO
LT L
ON
G2
12
SS3
043/
8" U
NC
NU
T8
13
SS30
43/
8" F
LAT
WA
SHER
414
DET
AIL
-C
DET
AIL
-D
H. L
.
L. L
. L.
L.
H. L
.
THIS
DO
CUM
ENT
AND
THE
WO
RKS
AND/
OR
INFO
RMAT
ION
CON
TAIN
EDTH
EREI
N AR
E TH
E CO
NFID
ENTI
ALAN
D PR
OPR
IETA
RY P
ROPE
RTY
OF
MA
TRIX
APP
LIED
TEC
HN
OLO
GIE
SAN
D SH
ALL
BE U
SED
ONL
Y FO
R TH
EIN
TEN
DED
PURP
OSE
AND
PRO
JECT
.IT
MAY
NOT
BE
COPI
ED IN
WHO
LEO
R IN
PAR
T. P
ARTS
MAY
NOT
BE
FABR
ICAT
ED F
ROM
THE
DO
CUM
ENT,
AND
THE
INFO
RMAT
ION
THER
EIN
MAY
NO
T BE
DIV
ULGE
D W
ITHO
UTM
ATR
IX A
PPLI
ED T
ECH
NO
LOG
IES
EXPR
ESS
WRI
TTEN
PER
MIS
SION
.
CUST
OM
ER:
LOC
ATIO
N:
DRA
WN
BY DAT
E
JOB
No.
CHEC
KED
BY PAPE
RSI
ZE
TAN
KD
IA.
TAN
KH
T.T
ANK
No.
DRA
WIN
G T
ITLE
DRA
WIN
G N
UM
BER
REV.
DET
AIL
SBY
DAT
ER
EV.
A3
IP
400
0 L
EVEL
IN
DIC
ATO
R AS
SEM
BLY
AR
TICU
LATE
D F
.S.L
.
DA
TE
NO
TES
:1.
UN
LESS
OTH
ERW
ISE
STA
TED
ALL
DIM
ENSI
ON
S IN
MIL
LIM
ETR
ES.
(286
5)
TAN
K
FLO
OR
TAN
K SH
ELL
(OU
TSID
E )
5TY
P
LEV
EL I
ND
ICAT
ING
M
ARKS
ON
TAN
K BY
CU
STO
MER
TAN
K SH
ELL
(OU
TSID
E )
5TY
PTA
NK
RO
OF
(430
)
140
TAN
K RO
OF
CUT
OU
T TE
MPL
ATE
160
10
11
9
3854
ACCORDING TO FSL TRAVEL
1
2 25
12 13 149
FOR
INFO
RMAT
ION
6
77
6
77
Floating Suction LineINPUT DATA SHEET
°C
(H.H.L.L)
EXISTING TANK ACCESSORIES AND INFORMATION
SUCTION LINE OPTIONS
*PLEASE PROVIDE PLAN OF TANK NOZZLES & INTERNAL PIPING
0.7 (default)
COMMENTS
Max. Fill Height (H.L.L.)
Floor Coating:
Product Stored: Max. Product Temperature:
Suction Nozzle Projection Inside Tank:
Suction Nozzle Centerline Height:
Max. Manway or Cleanout Door Opening Size:
Welding in Tank Permitted
Floor Slope:
mm
m
dd/mm/yrTANK INFORMATION REQUIRED
Location: Date:Tank Owner:
mTank Ø: Tank HeightTank Number:
mm
Product S.G. at 60°F (15.6°C):
mm
mm
mm
Unpainted
Yes
Floating Roof (Provide Drawing)
None
Sample Line(s)
Level Indicator
Roof Columns (Provide Drawing)
Heater Coils (Provide Drawing)
-
Metric