Maternal/Fetal MonitorFrom Antepartum to Pospartum monitoring applications
AV-9005A
©2010, AMBISEA Technology Corp.,Ltd Rev1.0.01/2010AMBISEA is a registered trademark of AMBISEA Technology Corp., Ltd
Standard Parameters• FHR • ECG/HR • Temperature• FM • SPO2 • Respiration• TOCO • NIBP • Pulse
Features• 12.1” Largescreen Color TFT Display, touch screen• Builtin high capability Lithiumion battery, working over 2 hours• Recall 120hours fetal monitoring date.• The time of Trend graph: 12 hours, 24hours, 48hours, 96hours optional• Recall and storage 400 groups of NIBP• Support patient information Input• Different color of waveform selectable• Various interface selection: standard interface, Big font interface, OxyCRGinterface, fetal monitoring interface, fetal cascade interface.• Audible and visual alarm• FHR automatic scoring report, output by printer• Manual or Automatic Fetal Movement counting selectable• 112mm wide thermal printer, fit for international standard, fetal wave andparameters can be printed in real time• Optional twins monitoring function• Builtin IP net socket, standard Ethernet network• Wire and wireless net work available, total 128 units of monitor can be set up acentralAccessories• Standard: 1 x FHR probe, 1 X FM Event Marker, 1 x TOCO probe, 1 x BuildinBattery, 1x builtin printer, 1 x Ground Line.• Optional: Nellcor SPO2, Twins, IBP, EtCO2, VCG, Special accessories for Neonataland Pediatric Patient.
®
W ith its 12.1 TFT LCD and foldable touch screen, the AV9005A has excellent performances, a powerful memory andplenty of features to support application from antepartum topostpartum. It embeds advanced ARM CPU for fast performances,as well as highly reliable fetal, ECG and NIBP modules.The AV9005A has various user interfaces suitable for differentapplications: 3 parameters, 9 parameters, big fonts display andparameter list. It also supports userdefined colors and patientinformation input. It has a special automatic scoring systems, 120hours of full parameters realtime waveforms recording and 1 hourof sound storage.Its 3level smart light/voice alarm is also recorded accurately forlater on review of the patient status. As for its communicationcapabilities, it is equipped with a USB port for software update andan Ethernet port for communication with a central monitoringsystem.
Technical SpecificationsFetal Heart Rate• Working Mode: Pulsed Wave Doppler ultrasound• Ultrasound Frequency: 1MHZ• Ultrasound Output Intensity :ISATA <3Mw/cm2• FHR Accuracy: ± 1bpm• FHR Range: 50 ~ 210bpm• FHR Alarm Setting: adjustable and automemory the upper and lower limit.Fetal Movement• Working Mode: Auto or Manual fetal movement markTOCO• Working mode: pressure transducer• TOCO alarm range:. Upper Limit: 1~ 100% factory setting: 100%. Upper Limit: 0~ 99% factory setting: 0%• Comparative TOCO display: 0 ~ 100%• TOCO measuring nonlinearity error: ± 10• Zero OCTO: 0,5, 10, 15, 20 optionalPackaging Content• 1 x Power Plug• 1 x Earth Line• 1 x 5 lead ECG cable• 1 x Adult NIBP cuff• 1 x NIBP cable• 1 x Spo2 sensor• 1 x Temp sensor• 1 x 3in1 Probe (FHR, TOCO, FM)• 2 x Binding Strap• 1 x Bottle of Transmission Gel• 1 x Printer paper roll• 1 x bag of Electrodes• 1 x Warranty Card• 1 x Packing List• 1 x Certificate of compliance• 1 x Receiving Report• 1 x User Manual
Headquarter
AMBISEA Technology Corp., Ltd3905 Two Exchange Square, Suite 7698,8 Connaught Place, Central, HongkongPhone : +852 35966988 Fax : +852 28911618
China Operations and Technical Support
AMBISEA Technology, China Operations5A, ShunTian Building, 62 GuiMiao Road
Nanshan Dist., Shenzhen City, Guangdong, China 518052Phone : +86 75526475192 Fax : +86 75526475193
Email : [email protected] Website : www.ambisea.com
Big Fonts
Trends
Twins Monitoring