© BINDER GmbH 1

Dynamic Temperature &Climate Simulation Measurement

April 2016

ANALIS SA/NV IS DISTRIBUTOR FOR BINDER ON BELGIUM AND LUXEMBOURG MARKET WWW.ANALIS.BE [email protected]

Page 2: Material testing & Q - ICH - Environmental Simulation Test - Temperature & Humidity Control

© BINDER GmbH 2

Content

► Introduction

► Determination of the cooling rate acc. To IEC 60068-3-5

► Test Norms

► Temperature Distribution

► Humidity

► Systems & Solutions

► Applications ► Various sectors for climatic and testing chambers

ANALIS SA/NV IS DISTRIBUTOR FOR BINDER ON BELGIUM AND LUXEMBOURG MARKET WWW.ANALIS.BE [email protected]

Page 3: Material testing & Q - ICH - Environmental Simulation Test - Temperature & Humidity Control

© BINDER GmbH 3

Dynamic Temperature and Climate Simulation Chambers

BINDER environmental chambers are perfectly suited to material testing under dynamic conditions. The standard rapid alternation speeds of around 5 K/min make standard-compliant testing possible.

An environmental simulation chamber of the MK and MKT Series is suitable for complex temperature profiles in the range of -40 °C (MK) or -70 °C (MKT) to 180 °C.

MKF & MKFT suitable for rapide temperature and humidity control

INTRODUCTION

ANALIS SA/NV IS DISTRIBUTOR FOR BINDER ON BELGIUM AND LUXEMBOURG MARKET WWW.ANALIS.BE [email protected]

Page 4: Material testing & Q - ICH - Environmental Simulation Test - Temperature & Humidity Control

© BINDER GmbH 4

Determination of the cooling rate acc. To IEC 60068-3-5

► E.g. MK: ► Tmin = -40 °C ► Tmax = 180 °C Temperature span is 220 °C Maintain Tmax ( here 180°C ) - set point is Tmin

► Start measuring the time 158 °C when 90% of the temperature span are achieved (here 158 °C )► Stop time measurement when 10% of the temperature span are

reached ( here -18 °C ) To determine the cooling time Δt (min) Temperature differential ΔT is known► Unit of the cooling rate is ΔT/Δt °C/min

ΔT80% of the temperature span

Δt

ANALIS SA/NV IS DISTRIBUTOR FOR BINDER ON BELGIUM AND LUXEMBOURG MARKET WWW.ANALIS.BE [email protected]

Page 5: Material testing & Q - ICH - Environmental Simulation Test - Temperature & Humidity Control

© BINDER GmbH 5

Test Norms

► International and national test norms specify under which conditions constant and dynamic testing shall be performed

► The IEC (International Electrotechnical Commission) is a platform for industry and authorities

► The IEC is developing worldwide recognized International Standards for devices containing electro technology

► The IEC 60068 Standard specifies the conditions for environmental testing

► It is transformed into national and regional standards by the member committees (countries)

► The implementation in the EU is entitled EN 60068

ANALIS SA/NV IS DISTRIBUTOR FOR BINDER ON BELGIUM AND LUXEMBOURG MARKET WWW.ANALIS.BE [email protected]

Page 6: Material testing & Q - ICH - Environmental Simulation Test - Temperature & Humidity Control

© BINDER GmbH 9

Dynamic Temperature and Climate Simulation Chambers MK | Dynamic climate chambers for rapid temperature changes Temperature range: -40 °C to 180 °C

MKF | Dynamic climate chambers for rapid temperature changes with humidity control Temperature range: -40 °C to 180 °C - Humidity range: 10 % to 98 % RH -

MKT | Dynamic climate chambers for rapid temperature changes with extended low temperature range

Temperature range: -70 °C to 180 °C - 4 zero-voltage relay contacts that can be activated via MCS controller - Programmable condensation protection for test material

Heated viewing window with LED interior lighting

MKFT | Dynamic climate chambers for rapid temperature changes with humidity control and extended low temperature range

Temperature range: -70 °C to 180 °C - Humidity range: 10 % to 98 % RH

SYSTEMS & SOLUTION SEE MORE CLICK HERE

ANALIS SA/NV IS DISTRIBUTOR FOR BINDER ON BELGIUM AND LUXEMBOURG MARKET WWW.ANALIS.BE [email protected]

Page 7: Material testing & Q - ICH - Environmental Simulation Test - Temperature & Humidity Control

© BINDER GmbH 10

Applications : Automotive – Test Cycle for Adhesive Bonded Joints

0 1 3 4 5 6 7 8 9 10 11 12

-40

-20

0

20

40

60

80

100Temperature / °C Humidity / %

Time / h

Humidity offHumidity on

Duration per cycle: 12 hNumber of cycles: 20

ANALIS SA/NV IS DISTRIBUTOR FOR BINDER ON BELGIUM AND LUXEMBOURG MARKET WWW.ANALIS.BE [email protected]

Page 8: Material testing & Q - ICH - Environmental Simulation Test - Temperature & Humidity Control

© BINDER GmbH 11

Why is the extended climate range needed?

► Because various automotive test norms specify challenging temperature / humidity profiles where a fast dehumidification is mandatory

Humidity without controlled compresdry air purge

Humidity with controlled dry air purge see more

Temperature

ANALIS SA/NV IS DISTRIBUTOR FOR BINDER ON BELGIUM AND LUXEMBOURG MARKET WWW.ANALIS.BE [email protected]

Page 9: Material testing & Q - ICH - Environmental Simulation Test - Temperature & Humidity Control

© BINDER GmbH 12

Applications : BINDER MKF SYSTEMS in Polymer Research

► Technical University, located in Germany► Basic polymer research

► The Polymer Institute examines the Aging behavior Lower and upper destruct limits

of newly developed materials in order to validate the intended operation range referring to temperature and humidity

► The institute uses a BINDER MKF 240

► Stress testing polymer for several cyclic stress tests: Temperature cycle from -30 - 150 °C at different relative humidities between 30 – 98 % RH

More information click here

ANALIS SA/NV IS DISTRIBUTOR FOR BINDER ON BELGIUM AND LUXEMBOURG MARKET WWW.ANALIS.BE [email protected]

DOWNLOAD BINDER Artificial aging

Page 10: Material testing & Q - ICH - Environmental Simulation Test - Temperature & Humidity Control

© BINDER GmbH 13

Various sectors for climatic and testing chambers

Automotive Electro Components Test Laboratories Aviation Defense

Electronic devices Nano Technology Fine mechanics Construction materialsAuthorities