Jim Mimlitz
SCADAmetrics
Master Metering
Using Your SCADA System
A Briefing to the AWWA Midwest Water & Wastewater Technology Conference
05 June 2014 Grayslake, Illinois
© 1995-2014 COPYRIGHTSCADAMETRICS ALL RIGHTS RESERVED.
0
10
0
101
1100
1
11
00
![Page 2: Master Metering using your SCADA System](https://reader030.fdocuments.us/reader030/viewer/2022020101/55a797df1a28ab841f8b48f6/html5/thumbnails/2.jpg)
Why Integrate Master Meter Data
Into The SCADA System?
• Track Distribution System Flows In Realtime.
• Bulk Customer Billing & Automatic Reports.
• Detect and Zone Transmission Line Leaks.
• Increase Employee Safety.
• Improve Data Accuracy.
• Leverage Already-Existing SCADA System Infrastructure.
The Bottom Line: Reduce Operational Costs
ISAWWATraining
© 1995-2014
COPYRIGHT SCADAMETRICS.
ALL RIGHTS RESERVED.
SCADAmetrics
![Page 3: Master Metering using your SCADA System](https://reader030.fdocuments.us/reader030/viewer/2022020101/55a797df1a28ab841f8b48f6/html5/thumbnails/3.jpg)
Track Distribution System
Flows In Realtime…
SCADA Systems Excel At:
• Collecting Large Amounts of Sensor Data Within Short Time Intervals• Graphical Presentation of Data• Alarming Unusual Conditions (Audible Alerts, Text Messages, etc.)• Graphical Presentation of Historical Trending Charts
ISAWWATraining
© 1995-2014
COPYRIGHT SCADAMETRICS.
ALL RIGHTS RESERVED.
SCADAmetrics
GPM
GAL
477724330
GALLONS
950.2
GPM
![Page 4: Master Metering using your SCADA System](https://reader030.fdocuments.us/reader030/viewer/2022020101/55a797df1a28ab841f8b48f6/html5/thumbnails/4.jpg)
Bulk Customer Billing &
Automatic Reports…
Connect SCADA Database to:
• Billing Software System• Excel Spreadsheets
ISAWWATraining
© 1995-2014
COPYRIGHT SCADAMETRICS.
ALL RIGHTS RESERVED.
SCADAmetrics
![Page 5: Master Metering using your SCADA System](https://reader030.fdocuments.us/reader030/viewer/2022020101/55a797df1a28ab841f8b48f6/html5/thumbnails/5.jpg)
Bulk Water
Customer
(RE Water Corporation)
Purchase Point
From Supplier
(City of Albion, IL)
Standpipe
Storage
Pump Station #1 Flow
– RE Water (Bulk Customer) System Flow
– Standpipe Storage Flow
= Approximate Residential And Business Usage
Pump Station #1
Water Company
SCADA Server
Residential And Business
Customers
ISAWWATraining
© 1995-2014
COPYRIGHT SCADAMETRICS.
ALL RIGHTS RESERVED.
SCADAmetrics
Detect and Zone
Transmission Line Leaks…
Pump Station #2
Flow (gpm)
Overnight Usage Trends
Provide A Useful Measure
Of Potential Water Leaks
![Page 6: Master Metering using your SCADA System](https://reader030.fdocuments.us/reader030/viewer/2022020101/55a797df1a28ab841f8b48f6/html5/thumbnails/6.jpg)
ISAWWATraining
© 1995-2014
COPYRIGHT SCADAMETRICS.
ALL RIGHTS RESERVED.
SCADAmetrics
Increase Employee Safety…
• Meter Vaults – Safety Hazard.• OSHA Confined Space Compliance.
![Page 7: Master Metering using your SCADA System](https://reader030.fdocuments.us/reader030/viewer/2022020101/55a797df1a28ab841f8b48f6/html5/thumbnails/7.jpg)
ISAWWATraining
© 1995-2014
COPYRIGHT SCADAMETRICS.
ALL RIGHTS RESERVED.
SCADAmetrics
Improve Data Accuracy…
SCADA/Meter Instrumentation Saved The Utility $14K On This Month’s Bill.
4 Below-GradeMaster Meters Eyeball-Read By Human Meter Reader. (Errors)
4 Master Meters Machine-Read By SCADA System.(Error-Free)
![Page 8: Master Metering using your SCADA System](https://reader030.fdocuments.us/reader030/viewer/2022020101/55a797df1a28ab841f8b48f6/html5/thumbnails/8.jpg)
ISAWWATraining
© 1995-2014
COPYRIGHT SCADAMETRICS.
ALL RIGHTS RESERVED.
SCADAmetrics
Leverage Already-Existing
SCADA Infrastructure…
• Computer Hardware
• Computer Software
• Communication Infrastructure(Radio, Fiber-Optic, Etc.)
• Remote Sites(eg Water Towers, Pumping Stations)
![Page 9: Master Metering using your SCADA System](https://reader030.fdocuments.us/reader030/viewer/2022020101/55a797df1a28ab841f8b48f6/html5/thumbnails/9.jpg)
How To Integrate Master Meters
Into A SCADA System?
• Case Study I –Licensed FM Radio Telemetry
• Case Study II –Cellular Ethernet Telemetry
• Case Study III –Extraterrestrial Satellite Radio Telemetry
ISAWWATraining
© 1995-2014
COPYRIGHT SCADAMETRICS.
ALL RIGHTS RESERVED.
SCADAmetrics
![Page 10: Master Metering using your SCADA System](https://reader030.fdocuments.us/reader030/viewer/2022020101/55a797df1a28ab841f8b48f6/html5/thumbnails/10.jpg)
• Collect Data From 34 Master Meters(Various Brands) Using SCADA System.
• 4 Readings Per Day.
• Revenue-Grade AccuracyOf Meter Readings.
• Accelerated Leak Detection.
• Minimize Recurring Costs:Low Energy Footprint (Solar Solution)Eliminate Manual Read PayrollReduce Fuel and Vehicle Wear/TearReduce Data Entry and Reporting Time
• Increase Employee Safety.
• 3 Year Investment Payback.0 105
miles
Case Study I –
Licensed FM Radio Telemetry
ABS Water Cooperative (Clayton, IL)
ISAWWATraining
© 1995-2014
COPYRIGHT SCADAMETRICS.
ALL RIGHTS RESERVED.
SCADAmetrics
Project Goals:
![Page 11: Master Metering using your SCADA System](https://reader030.fdocuments.us/reader030/viewer/2022020101/55a797df1a28ab841f8b48f6/html5/thumbnails/11.jpg)
• Several Meter Brands MixedThroughout System
• Customer Desired To UtilizeExisting Meters
Sensus
Badger
34 Master Meters…
ISAWWATraining
© 1995-2014
COPYRIGHT SCADAMETRICS.
ALL RIGHTS RESERVED.
SCADAmetrics
![Page 12: Master Metering using your SCADA System](https://reader030.fdocuments.us/reader030/viewer/2022020101/55a797df1a28ab841f8b48f6/html5/thumbnails/12.jpg)
• Utilize Absolute Encoder TechnologyNo Pulse Signaling (Pulse-Counting Errors)No 4-20mA Signaling (Integration Errors)
• Required Register Retrofits:Sensus – ICE RegistersBadger – ADE Registers
Revenue-Grade Accuracy…
ISAWWATraining
© 1995-2014
COPYRIGHT SCADAMETRICS.
ALL RIGHTS RESERVED.
SCADAmetrics
Sensus ICERegister
Badger ADERegister
![Page 13: Master Metering using your SCADA System](https://reader030.fdocuments.us/reader030/viewer/2022020101/55a797df1a28ab841f8b48f6/html5/thumbnails/13.jpg)
Minimize Recurring Costs…
ISAWWATraining
© 1995-2014
COPYRIGHT SCADAMETRICS.
ALL RIGHTS RESERVED.
SCADAmetrics
Solar-Power Eliminated Need For Electric Utility Service:• No Up-Front Utility Hookup Charges• No Monthly (Minimum) Usage Charges
![Page 14: Master Metering using your SCADA System](https://reader030.fdocuments.us/reader030/viewer/2022020101/55a797df1a28ab841f8b48f6/html5/thumbnails/14.jpg)
Lexan Window“Visual Read” Backup
Telemetry Hardware Diagram…
ISAWWATraining
© 1995-2014
COPYRIGHT SCADAMETRICS.
ALL RIGHTS RESERVED.
SCADAmetrics
Solar Panel (50W) andBattery Charge Controller
EM-100 EtherMeterSCADA/Meter Gateway
DL-3400FM Telemetry Radio
Fusing
12V Battery
Radio Communications UsingRS-232 and Modbus/RTUIndustrial Protocol
Water Towers Were NaturalRepeaters For Meters InLow-Lying Areas.
![Page 15: Master Metering using your SCADA System](https://reader030.fdocuments.us/reader030/viewer/2022020101/55a797df1a28ab841f8b48f6/html5/thumbnails/15.jpg)
• Software Library Created ThatLinked the SCADA Database To Excel Spreadsheets.
• Automatic and Fast ReportGeneration.
• Data Analytics QuantifiesUsage Anomalies/Leaks.
• Data Transcription ErrorsEliminated.
Reduced Data Entry and
Reporting Time… ISAWWATraining
© 1995-2014
COPYRIGHT SCADAMETRICS.
ALL RIGHTS RESERVED.
SCADAmetrics
![Page 16: Master Metering using your SCADA System](https://reader030.fdocuments.us/reader030/viewer/2022020101/55a797df1a28ab841f8b48f6/html5/thumbnails/16.jpg)
• Collect Meter Data From 20 Custody Transfer Meters (Various Brands) UsingCellular Ethernet Technology and the Existing SCADA System.
• Main Purpose = Billing. Revenue-Grade Accuracy Required.
• Readings Every 15 Minutes.
• Minimize Recurring Costs:Low Energy Footprint (Use Solar Wherever Power Not Available)Eliminate Ineffective Legacy System and Associated Monthly Contract
• Interface With Bulk Customer Telemetry Equipment.
Case Study II –
Cellular-Ethernet Telemetry
Utility:Missouri American Water Company (Saint Louis, MO)
Project Goals:
ISAWWATraining
© 1995-2014
COPYRIGHT SCADAMETRICS.
ALL RIGHTS RESERVED.
SCADAmetrics
![Page 17: Master Metering using your SCADA System](https://reader030.fdocuments.us/reader030/viewer/2022020101/55a797df1a28ab841f8b48f6/html5/thumbnails/17.jpg)
Water
Company
HQ
Cellular
Carrier
Master Meters
Retrofitted with
Encoder-Type Registers
IMPROVED
MASTER
METERING
SYSTEM
Local
Cellular Tower
Infrastructure
Private
Cellular
Network
Industrial
Ethernet
Protocols
Cellular Ethernet System…
ISAWWATraining
© 1995-2014
COPYRIGHT SCADAMETRICS.
ALL RIGHTS RESERVED.
SCADAmetrics
• Private Cellular Network For SCADA Security.
• Data Communications Using KepServerEx.
• Nice Extra: Modbus/UDP Industrial Protocol (not Modbus/TCP).
• UDP Protocol Achieved Order-of-Magnitude Decrease In Billable Cellular Kilobytes.
![Page 18: Master Metering using your SCADA System](https://reader030.fdocuments.us/reader030/viewer/2022020101/55a797df1a28ab841f8b48f6/html5/thumbnails/18.jpg)
ISAWWATraining
© 1995-2014
COPYRIGHT SCADAMETRICS.
ALL RIGHTS RESERVED.
SCADAmetrics
Cellular Master Meter Site…
![Page 19: Master Metering using your SCADA System](https://reader030.fdocuments.us/reader030/viewer/2022020101/55a797df1a28ab841f8b48f6/html5/thumbnails/19.jpg)
Cellular Telemetry
Hardware Diagram… ISAWWATraining
© 1995-2014
COPYRIGHT SCADAMETRICS.
ALL RIGHTS RESERVED.
SCADAmetrics
Cellular Antenna
EM-100 EtherMeterSCADA/Meter Gateway
AC/DC Power Supply (24V)
Raven-ECellular Gateway (Modem)
ADAM-40244-20mA Output Module(Signaling To Bulk CustomerTelemetry)
![Page 20: Master Metering using your SCADA System](https://reader030.fdocuments.us/reader030/viewer/2022020101/55a797df1a28ab841f8b48f6/html5/thumbnails/20.jpg)
ISAWWATraining
© 1995-2014
COPYRIGHT SCADAMETRICS.
ALL RIGHTS RESERVED.
SCADAmetrics
Case Study III – Extraterrestrial
Satellite Radio Telemetry…
• Collect Meter Data From Custody Transfer Meters (Various Brands) UsingExtraterrestrial Satellite Modem Technology.(Cellular Not Available, FM Radio Insufficient Range).
• Main Purpose = Billing. Revenue-Grade Accuracy Required.
• Readings Every 6 Hours.
• Minimize Recurring Costs:Low Energy Footprint (Utility Power Not Available).
Utility:Northwest Area Water Supply District (Bismark, ND)
Project Goals:
![Page 21: Master Metering using your SCADA System](https://reader030.fdocuments.us/reader030/viewer/2022020101/55a797df1a28ab841f8b48f6/html5/thumbnails/21.jpg)
ISAWWATraining
© 1995-2014
COPYRIGHT SCADAMETRICS.
ALL RIGHTS RESERVED.
SCADAmetrics
ISAWWATraining
© 1995-2014
COPYRIGHT SCADAMETRICS.
ALL RIGHTS RESERVED.
SCADAmetrics
Case Study III – Extraterrestrial
Satellite Radio Telemetry…
![Page 22: Master Metering using your SCADA System](https://reader030.fdocuments.us/reader030/viewer/2022020101/55a797df1a28ab841f8b48f6/html5/thumbnails/22.jpg)
ISAWWATraining
© 1995-2014
COPYRIGHT SCADAMETRICS.
ALL RIGHTS RESERVED.
SCADAmetrics
Satellite Telemetry
Hardware Diagram…
JouBeh 9602WSatellite Transceiver
Satellite Antenna
EM-100 EtherMeterSCADA/Meter Gateway
![Page 23: Master Metering using your SCADA System](https://reader030.fdocuments.us/reader030/viewer/2022020101/55a797df1a28ab841f8b48f6/html5/thumbnails/23.jpg)
ISAWWATraining
© 1995-2014
COPYRIGHT SCADAMETRICS.
ALL RIGHTS RESERVED.
SCADAmetrics
Satellite Telemetry Typical Site…
Hardware Diagram…
Solar Panel.
Telemetry Enclosure.
Below-Grade Master Meter:
Badger w/ ADE Register(Absolute Digital Encoder).
![Page 24: Master Metering using your SCADA System](https://reader030.fdocuments.us/reader030/viewer/2022020101/55a797df1a28ab841f8b48f6/html5/thumbnails/24.jpg)
ISAWWATraining
© 1995-2014
COPYRIGHT SCADAMETRICS.
ALL RIGHTS RESERVED.
SCADAmetrics
Satellite – SCADA Integration
Nice Extras(Self-Diagnostics):
Satellite Signal Strength
Battery Voltage
![Page 25: Master Metering using your SCADA System](https://reader030.fdocuments.us/reader030/viewer/2022020101/55a797df1a28ab841f8b48f6/html5/thumbnails/25.jpg)
ISAWWATraining
© 1995-2014
COPYRIGHT SCADAMETRICS.
ALL RIGHTS RESERVED.
SCADAmetrics
Satellite – Automatic
Report Generation…
![Page 26: Master Metering using your SCADA System](https://reader030.fdocuments.us/reader030/viewer/2022020101/55a797df1a28ab841f8b48f6/html5/thumbnails/26.jpg)
SCADA Useful For…
• Tracking Distribution System Flows In Realtime.
• Alarming.
• Historical Trending.
• Data Visualization.
• Assisting With Bulk Customer Billing
• Generating Reports Automatically.
• Detecting and Zoning Transmission Line Leaks.
• Increasing Employee Safety.
• Improving Data Accuracy (Eliminating Human Reading and Transcription Errors).
Key Technology Components…
• Absolute Encoder-Based Meter Registers.
• Leverage Existing SCADA Infrastructure.
• Utilize Most Suitable Communication Method (eg. FM Radio, Cellular, Satellite).
• May Utilize Solar Power When Needed.
ISAWWATraining
© 1995-2014
COPYRIGHT SCADAMETRICS.
ALL RIGHTS RESERVED.
SCADAmetrics
Summary & Key Points –
![Page 27: Master Metering using your SCADA System](https://reader030.fdocuments.us/reader030/viewer/2022020101/55a797df1a28ab841f8b48f6/html5/thumbnails/27.jpg)
Jim Mimlitz
SCADAmetrics
Saint Louis, Missouri
scadametrics.com
ISAWWATraining
© 1995-2014
COPYRIGHT SCADAMETRICS.
ALL RIGHTS RESERVED.
SCADAmetrics