Marker Text - Wedgewood Golf & Country Estate · PDF fileW01 W02 W12 N bic bic bic bic rwp rwp...

3

Transcript of Marker Text - Wedgewood Golf & Country Estate · PDF fileW01 W02 W12 N bic bic bic bic rwp rwp...

Page 1: Marker Text - Wedgewood Golf & Country Estate · PDF fileW01 W02 W12 N bic bic bic bic rwp rwp ... and where applicable Project Specifications and/or Bill of ... Contractors must view
Page 2: Marker Text - Wedgewood Golf & Country Estate · PDF fileW01 W02 W12 N bic bic bic bic rwp rwp ... and where applicable Project Specifications and/or Bill of ... Contractors must view
Page 3: Marker Text - Wedgewood Golf & Country Estate · PDF fileW01 W02 W12 N bic bic bic bic rwp rwp ... and where applicable Project Specifications and/or Bill of ... Contractors must view

Occupancy or Building Classification H4 - Dwelling house

Design Population 2 Persons per bedroom

Climatic Zone 4 - Temperate Coastal

Constant Conductance factor for Climatic Zone 1,4 CU

Constant Solar Heat Gain Coefficient factor for Climatic Zone 0,13 SHGC

Percentage fenestration area to nett floor area

Ground Floor 26,04 %

CALCULATED VALUES FOR CONDUCTANCE AND SOLAR HEAT GAIN (Area x U value) (Area x E x SHGC)

Floor Window No. Area m2 Orientation Shading (P/H) Exposure Factor(E) SHGC U Value Conductance Solar Heat Gain

Ground W01 1,12 SOUTH EAST 0,05 0,78 0,8 SEE SPEC. - 01 6,7774 0,69888 GLAZING SPECIFICATION - 01

Ground W02 1,12 SOUTH EAST 0,05 0,78 0,8 SEE SPEC. - 01 6,7774 0,69888 GLAZING SPECIFICATION - 01

Ground W04 1,12 SOUTH EAST 0,50 0,49 0,8 SEE SPEC. - 01 6,7774 0,43904 GLAZING SPECIFICATION - 01

Ground W05 1,12 SOUTH EAST 0,50 0,49 0,8 SEE SPEC. - 01 6,7774 0,43904 GLAZING SPECIFICATION - 01

Ground W06 1,12 SOUTH WEST 0,05 0,96 0,8 SEE SPEC. - 01 6,7774 0,86016 GLAZING SPECIFICATION - 01

Ground W07 1,12 SOUTH WEST 0,05 0,96 0,8 SEE SPEC. - 01 6,7774 0,86016 GLAZING SPECIFICATION - 01

Ground W08 0,71 SOUTH WEST 0,10 0,91 0,85 7,06 5,0126 0,549185 GLAZING SPECIFICATION - 02

Ground W09 0,71 SOUTH WEST 0,10 0,91 0,85 7,06 5,0126 0,549185 GLAZING SPECIFICATION - 02

Ground W10 1,12 SOUTH WEST 0,05 0,96 0,8 SEE SPEC. - 01 6,7774 0,86016 GLAZING SPECIFICATION - 01

Ground W11 1,12 SOUTH WEST 0,05 0,96 0,8 SEE SPEC. - 01 6,7774 0,86016 GLAZING SPECIFICATION - 01

Ground W12 3,13 NORTH WEST 0,50 0,6 0,71 4,37 13,6781 1,33338 GLAZING SPECIFICATION - 03

Ground W13 1,12 NORTH WEST 0,05 1,13 0,8 SEE SPEC. - 01 6,7774 1,01248 GLAZING SPECIFICATION - 01

Ground W14 1,12 NORTH WEST 0,05 1,13 0,8 SEE SPEC. - 01 6,7774 1,01248 GLAZING SPECIFICATION - 01

Ground W15 0,71 NORTH EAST 0,10 0,9 0,85 7,06 5,0126 0,54315 GLAZING SPECIFICATION - 02

Ground W16 0,71 NORTH EAST 0,10 0,9 0,85 7,06 5,0126 0,54315 GLAZING SPECIFICATION - 01

Ground D02 2,71 SOUTH EAST 2,00 0,21 0,71 4,37 11,8427 0,404061 GLAZING SPECIFICATION - 03

Ground D03 2,71 SOUTH EAST 0,50 0,49 0,71 4,37 11,8427 0,942809 GLAZING SPECIFICATION - 03

Ground D04 2,71 NORTH WEST 0,50 0,6 0,71 4,37 11,8427 1,15446 GLAZING SPECIFICATION - 03

Ground D05 6,13 NORTH WEST 1,00 0,36 0,71 4,37 26,7881 1,566828 GLAZING SPECIFICATION - 03

TOTAL: 31,43 163,82 15,33

TARGETS VS CALCULATED VALUES FOR CONDUCTANCE AND SOLAR HEAT GAIN(Nett floor Area x CU - climate zone 1) TARGET VALUE (Fenestration Area x U-value specified) CALC. VALUE

Conductance 120,7 1,4 168,98 See table above for window details 163,82(Nett floor Area x SHGC climate zone 1) (Fenestration Area x E x SHGC specified

Solar Heat Gain 120,7 0,13 15,69 See table above for window details 15,33

GLAZING SPECIFICATION - 01 CONDUCTANCE ELEMENT SHGC

LOWER GLAZED PANEL 1,8354 0,71

All glazing below 900mm from finished floor level. 38% of Fenestration element

UPPER GLAZED PANEL 4,942 0,85

All glazing above 900mm from finished floor level. 62% of Fenestration element

6,7774 0,8

GLAZING SPECIFICATION - 02 CONDUCTANCE ELEMENT SHGC

WHOLE GLAZED PANEL 7,06 0,85

GLAZING SPECIFICATION - 03 CONDUCTANCE ELEMENT SHGC

WHOLE GLAZED PANEL 4,37 0,71

W12, D02, 03, 04, 05PFG 6,38mm Intruderprufe Low E Laminated Safety Glass: U-Value 3.646 x 1.2 = 4,37 : SHGC 0.71

CALCULATED VALUE DEEMED TO SATISFY SANS 10400 PART XA REQUIREMENTS

CALCULATED VALUE DEEMED TO SATISFY SANS 10400 PART XA REQUIREMENTS

WIND LOADING ON FENESTRATION ELEMENTS TO BE CONFIRMED BY STRUCTURAL ENGINEER. FENESTRATION TO BE DESIGNED ACCORDINGLY.

EXTERNAL WINDOW AND DOOR TO COMPLY WITH AND BE SANS 613 CERTIFIED, COMPLY WITH AAMSA AND SAGGA REQUIREMENTS.

PFG 6,38mm Intruderprufe Low E Laminated Safety Glass: U-Value 3.646 x 1.2 = 4,37 : SHGC 0.71

PFG 4.0mm Clear Glass: U-value 5.88 x 1.2 = 7.06 : SHGC 0.85

W01, 02, 04, 05, 06, 07, 10, 11, 13, 14

W08, 09, 15, 16

PFG 4.0mm Clear Glass: U-value 5.88 x 1.2 = 7.06 : SHGC 0.85

WEDGEWOOD ESTATE

GROU

ND F

LOOR

Fenestration Specification to meet Energy requirements

If above 15% then proceed with further calculations. Below 15% complies with the

deemed to satisfy provisions.

DEEMED TO SATISFY SOLUTION TO PART XA - FENESTRATION - ENERGY USAGE IN BUILDINGS - SANS 10400 HOUSE TYPE 2