Electrodiagnostic approach to the patient with suspected ...
MARCO - wischnew/pamela/internal/daq/...353П-46КС-27895-1105 1 Approved Deputy General Designer...
Transcript of MARCO - wischnew/pamela/internal/daq/...353П-46КС-27895-1105 1 Approved Deputy General Designer...
353П-46КС-27895-1105 1
Approved
Deputy General
Designer of TsSKB
____________ G. E. Fomin
"___"________ 2003
Materials on electrodiagnostic tests of Pamela for “Resource-DK1” SC
46КС-27895-1105
Leading designer
______________ V.N. Zyabchuk
"___"__________ 2003
Head of department 1107 Head of department 1105
______________ Sh. Z. Dusaev _____________ V.M. Fedorov
"___"__________ 2003. "___"_________ 2003.
Head of department 1402
_______________ Ya. A. Mostovoy
"___"__________ 2003.
Head of department 1405
_______________ S.A. Kustov
"___"___________ 2003.
Head of department 1406
_______________ A.S. Kolpachshikov
"___"___________ 2003.
2003
353П-46КС-27895-1105 2
TABLE OF CONTENTS
Introduction………………………..………………………………
1. Indication of safety measures...…………………………………
2. Types of hardware testing …......…………….…………………
3. Tests of the hardware as part of SC ……………………
3.1 Purposes and tasks of the tests.………………………………...
3.2 Tests support .................……………………………………….
3.3 Evaluation of test results ...........……………………………….
3.4 GTE composition …………………………………………………….
4. Test activations of "Pamela" RH with support systems of SC
4.1 Procedure of PAM TA .................……………………………….
4.1.1 Procedure of PAM TA fragment 1 – "RH test"…......................
4.1.2 Procedure of PAM TA fragment 2 – "Technological mode opera-
tion"………………….............................................................…
4.1.3 Procedure of PAM TA fragments 3, 4 – "GS
test"...........................................………………………………………
4.2 Procedure of PAM/HSRL TA.………………………
4.2.1 Procedure of PAM/HSRL TA fragment 5 – "Nominal operation,
standby electronics test"………
4.2.2 Procedure of PAM/HSRL TA fragment 6 – "Test of HSRL communi-
cation channels"......................………………………………………….
5. Joint Operation of Pamela and HSRL .............................................
6. Integrated tests of Pamela ...............................................................
7. Amount of Pamela’s retesting after replacement of its components or
replacement of “Resource DK” SC...............................................
8. Estimation of operating time ……………………………………
9. Order of Pamela’s activation, deactivation and re-set......................………………………………………….…..
Annex 1. List of test programs.
353П-46КС-27895-1105 3
INTRODUCTION
The document on electro-diagnostic testing of "Pamela" RH summarizes
the scope and procedure of electrical testing of "Pamela" RH in article 46КС and is
the initial data for development of documentation on integrated electrical testing of
the article.
The present document was developed according to:
“Materials on "Pamela" RH control logic” (353П-46КС-26166-1105).
LIST OF ACRONYMS
RH – research hardware;
TA – testing activation;
JO – joint operation;
IT – integrated testing;
CD – computer data;
TM – telemetry;
SI – signaling information;
BCS – on-board computer system;
BTCS – on-board time-coordinate synchronizer;
CRPDS – command relay/power distribution system;
GV–global variable
PSS –power supply system;
OBE HSRL – on-board equipment of high speed radio link;
CMS – command measuring system;
BDTS – on-board data telemetry system;
FTD – flight time diagram
User – user (cosmodrome);
GTC – ground testing complex;
353П-46КС-27895-1105 4
TP – technological prototype;
FP – flight prototype;
Terminal – terminal;
PSCU – Pamela storage & control unit;
GSE – ground support equipment;
RM –route marking;
TRD – transmission radiation detector;
MCMD – CC transmitted to the equipment by MCL;
GTE – ground testing equipment.
353П-46КС-27895-1105 5
1. INDICATION OF SAFETY MEASURES
Operation with "Pamela" RH is allowed to persons acquainted with mode
of functioning, structure of the article, operational documentation for the testing
equipment, trained in safety measures and entitled to work with electric facilities
of voltage below 1000 V in a group of 3 minimum and also entitled to work with
high-pressure vessels.
Operating personnel shall be acquainted with and observe the rules and
service instructions for instruments used for operations with the article and
also other rules and instructions in force at the manufacturing plant and at
the user’s.
353П-46КС-27895-1105 6
2. TYPES OF HARDWARE TESTING
At 46КС article (that is “Resource-DK1” SC) manufacturing plant ("Pro-
gress" plant) electrical testing of "Pamela" RH both for technological and flight
prototypes are carried out in the following phases:
- prior installation on the article – incoming test using "Pamela" RH GSE
according to documentation developed in INFN.
- after installation on the article:
1. Test activations with the article’s support systems including:
a) equipment serviceability checkout;
b) test of communications with BCtS, CRPDS, BTMS, BTCS;
c) test of communications with HSRL OBE using technological output of
TDM commutator.
2. Joint operation with HSRL OBE.
3. Integrated testing (IT).
Measurement of interference level and slump of voltage in supply circuits
is carried out for the technological prototype.
The consequence of testing flight prototype of "Pamela" RH at the user’s is
the same.
Diagram of work with technological and flight prototypes of "Pamela" RH
at the “Progress” plant and at the user’s is given in Figure1.
353П-46КС-27895-1105 7
Installation oftechnological prototype inSC PC
TA, JO, IT with technologi-cal prototype (2 cycles)
Activities on measuringmagnetic fields levels
Testing at the "Progress" plant
Incoming test oftechnological pro-totype
Incoming test of flightprototype
Dismounting oftechnological prototype
Instal. of flightprototype intoSC PC
TA, JO, IT with flight prototype (2 cycles)
Dismantling of flight prototype
Testing at the "Progress" plant
Instal. of flightprototype intoSC PC
TA, JO, IT with flight pro-totype (2 cycles)
Autonomous testing of flight proto-type within the scope of incoming test(external examination of RH and GSmono-units)
Test at the user’s
Meas interf level&volt slump
Figure 1 Diagram of work with TP and FP of "Pamela" RH at the "Progress" plant and at the user’s.
353П-46КС-27895-1105 8
3. TESTS OF THE HARDWARE AS PART OF THE ARTICLE
3.1 Purposes and tasks of the tests.
The purpose of electrical testing of "Pamela" RH as part of the article is to
confirm its serviceability as part of the article and availability for operation in ac-
cordance with its mission.
Tasks of the electrical testing of the hardware as part of the article are as
follows:
а) testing accuracy of hardware/46КС article systems connections;
б) testing the hardware serviceability including checkout of: PSCU, Termi-
nal, basic and standby protection units (PU) sets, basic and standby chan-
nels of basic and standby exchange adapter, basic and standby power sup-
ply, basic and standby electronics of the tracker, trigger, С4, ND, "I-DAQ"
system and also memory modules А and В;
в) testing electric interaction of the hardware with support systems of the
article: BCtS, CCIU, BTMS, CRPDS, HSRL OBE and also electric interac-
tion of communication lines with these systems.
To test communication lines between the hardware and support systems of
the article it is necessary to perform:
1. Two-way exchange of information (delivery of macro commands
(MCMD) to the hardware and receipt of service information from
the hardware) by line A and line B using the terminal – BCtS
communication test.
2. Issue of all necessary CC to the hardware under sequential dis-
connection of buses Еок1, Еок2 – CRPDS communication test.
3. Transmission of test information to HSRL OBE by the primary
and standby channel – HSRL communication test.
4. Issue of synchrosignals to the hardware by channel 1 and 2 -
CCIU communication test
353П-46КС-27895-1105 9
5. Assessment of TM for reference values – BTMS communication
test.
Functional scheme of communication between "Pamela" RH and GTS and
article’s systems is given in figure 2.
PSS
CRPDS BCtS CCIU
"Pamela" RH
HSRL OBE BTMS GTS
CMS
Figure 2 Functional scheme of communication between "Pam-
ela" RH and support systems of article 46КС and GTS.
353П-46КС-27895-1105 10
3.2 Tests support.
All kinds of testing of the hardware as part of article 46КС are carried out
using ground testing complex on the basis of the control computer and mathemati-
cal test support. Hardware control in the course of the test activations and joint op-
eration with HSRL OBE is carried out by nominal program A11 using RAM Pro-
tocol. Hardware control in the course of IT is carried out by nominal program A11
initiated from OP.
Prior testing of "Pamela" RH as part of SC the following SC systems shall
be activated and ready for operation: BVS, BDTS, BTCS, CRPDS, PSS, CMS.
HSRL OBE shall be activated and ready for operation prior to the first download
session during PAM TA with HSRL, JO and IT.
Pressurized container with "Pamela" RH shall be in transport condition
with the cover closed, "Pamela" RH is nominally connected with the SC systems.
"Pamela" RH GSE shall be connected with "Pamela" RH through connector BCS
Х «ГН15Т.10» and connected with HSRL OBE GTE according to operating in-
struction ИЭ17 part 44. During all kinds of electrical testing of "Pamela" RH as
part of the SC the ground cooling system (353У.9152.001) is connected to "Pam-
ela" RH cooling loop hydraulic pipelines. Connection of the cooling loop and fill-
ing the working fluid into the cooling loop are made according to Instructions
353У.9152.001 ПМ 2 and 353У.9152.001 ИЭ 2 during tests in “Progress” plant
and in the launch site accordingly. When the pressurized container is in operating
position or in any intermediate position the tests shall not be carried out.
Power dump is allowed at any operational phase of "Pamela" RH. After
restoration of supply it is necessary to activate test program ЖР67 by input 10 to
deactivate the hardware and to proceed with the nominal operation of "Pamela"
RH.
3.3 Evaluation of test results.
353П-46КС-27895-1105 11
Control of "Pamela" RH serviceability in the course of all electrical tests in
the article is executed by GTS using test programs ЖР67, ЖР68, ЖР69.
ЖР67 – program "Pamela" RH serviceability test in the course of TA with
support systems of the article";
ЖР68 – program "Control of "Pamela" RH/HSRL" JO;
ЖР69 – program "Test of "Pamela" RH serviceability in the course of IT".
To control serviceability of the hardware the following items are used by
GTS:
- nominal circuits of TM-control by channels of addressed TM selection;
- technological control circuits led to GTS through the signaling transmit-
ter (ST);
- Computer data (CD) transmitted from BCtS RAM through technologi-
cal channel "МТ".
Evaluation of tests results is carried out by ANP prints, tapes of open re-
cording of BTMS, testing scientific data.
3.4 GTE composition.
"Pamela" RH GSE (КБ7.101.00.000.00), GTE of HSRL OBE and ground
cooling system (353У.9152.001) are used in the course of testing of "Pamela" RH
as part of the article.
353П-46КС-27895-1105 12
4 TEST ACTIVATIONS OF "PAMELA" RH WITH
SUPPORT SYSTEMS OF SC
Test activations of "Pamela" RH with support systems are composed of
two parts: PAM TA and PAM TA with HSRL.
4.1 Procedure of PAM TA.
PAM TA are obtained using RAM Protocol 42 "Pamela" RH control in
TA" and test program ЖР67. The hardware control is performed by nominal pro-
gram А11.
RAM Protocol 42 is intended for:
- generation of ID for program А11 and the hardware,
- initiation of А11 program inputs at the necessary moments of time (ac-
cording to the time diagram),
- on-board and ground software synchronization,
- gaining CD by the test program through route mark (“RM”) channel,
- debugging test of MCMD "Lock the transmitter" and MCMD "Unlock
the transmitter" by the Terminal.
Prior PAM TA it is necessary to put BTMS in operational mode "ЗАП4",
ПрБ1.
PAM TA consist of the following fragments: "RH test, "Operation in tech-
nological regime", "GS test ".
It is possible to debug each fragment separately. Fragment debugging is de-
termined by availability of "1" in the bit corresponding to the fragment’s number,
GV "VPAMTA" (variant of «Pamela» RH test activations). The distribution of bits
of GV "VPAMTA" is given below:
23 … 6 5 4 3 2 1 0
fr.6 fr.5 fr.4 fr.3 fr.2 fr.1
Fragments 5, 6 are performed during Pam/HSRL TA.
353П-46КС-27895-1105 13
This variable is specified from the planning program КП6 prior ЖР67 ini-
tiation by input 1 and is transmitted to RAM Protocol42 by switching on and off
the "ПИ КТП", "ПИСУД" indicators from program ЖР67.
If necessary "Pamela" RH operation on a special program is provided in-
cluding "Pamela" RH dismantling from the article and testing by means of "Pam-
ela" RH GSE.
353П-46КС-27895-1105 14
4.1.1 Procedure of PAM TA fragment 1 – "RH test".
Time diagram of this fragment is given in fig. 3.
The following activities are performed on this fragment:
test of hardware/CRPDS communication (transmission of all CC provided
for "Pamela" RH by buses Еок1 and Еок2),
test of "Pamela" RH/BTSC communication (operation under alternate dis-
connection of primary and standby synchrosignals issue channels),
debugging test of MCMD "Lock the transmitter" and MCMD "Unlock the
transmitter" by the Terminal.
For this purpose four "Pamela" RH activations are performed: the first one
and the third one - with bus Еок2 being disconnected, the second one and the
fourth one – with bus Еок1 being disconnected. For it under the second activation
the first BTCS synchrosignals channel is active, under the third one - the second
BTCS synchrosignals channel is active.
Connection and disconnection of buses Еок1 and Еок2 and also connec-
tion/disconnection of BTCS channels are performed by program ЖР67.
In case of disconnection of channel 1 BTCS, channel 2 BTCS, connection
of channels (after debugging of input 1, 2, 3 of program Б76 respectively) attribute
"ABN BTCS" is analyzed by program ЖР67. When this attribute=1 "PAM ABN"
GV (abnormal completion of "Pamela" RH test activations) of value =1 is formed
and drift to line 50 is performed.
Program ЖР67 is initiated by input 1 from the planning program before the
beginning of fragment 1 and RAM Protocol 42 is initiated right after OP loading.
First program ЖР67 verifies temperature TM-parameters of "Pamela" RH
for compliance with allowed values. If there are no "anomalies", program ЖР67
synchronizes its work with on-board timing. For it ЖР67 sets indicator "ПИ КТП"
to 0 ("ПИ КТП" is on) and for two minutes it controls "МТ1" signal generated by
RAM Terminal42 with the state of "ПИ КТП" indicator being changed from “on”
353П-46КС-27895-1105 15
to “off” ("ПИ КТП" indicator status poll is performed by RAM Protocol42 with a
period of Т= 250 msec).
If "МТ1" signal is generated in due time ЖР67 program’s actions are as
follows:
-Within 3 seconds after synchronization ЖР67 changes "ПИ КТП" indica-
tor state by issuing CC "Off ПИ КТП" or CC "On ПИ КТП" and also issues CC
"On ПИ СУД" or "Off ПИ СУД" depending on the first position of GV "V PAM
TA" (for unit position of GV "V PAM TA" CC "Off ПИ СУД" is issued and for it
"ПИ СУД" indicator value=1).
- in 3 seconds after synchronization RAM Protocol42 performs control of
"ПИ КТП" indicator state and in case of its change it inserts "1" in position 1 of
its working cell "ВРАБ" if "ПИ СУД"=1 or – 0 if "ПИ СУД"=0;
- after that the rest three positions of "ВРАБ" variable are generated with
a period of 3 sec similarly to the above. So within 12 seconds from the
moment of synchronization the transmission of data on PAM TA frag-
ments processing on board is completed.
Then program ЖР67 executes the second RAM Protocol 42 timing with
zeroing the on-board time scale (ТБШВ) and time counters in the GTC and
BTMS. This is performed as follows:
-RAM program records the value=525258 in GV «КДБСК1.КОД» and
ТБШВ=0 in GV «ВЯ БСУ»;
- RAM program enters the setting of the time interval УВИД=tбшв +3sec.
for reference to the mark of seconds for activation of program A40 by input 1.
- during 3 seconds program ЖР67 controls the generation of "МТ" signal
(140478), formed by A40 program.
After that, program ЖР67 (If "МТ" signal from program A40 is generated
in due time) executes clearance of time meters at GTS and BTMS and proceeds
with its work according to the timing diagram.
353П-46КС-27895-1105 16
Upon completion of the fragment debugging program ЖР67 executes dis-
connection of "ПИ КТП" indicator.
In abnormal completion of PAM TA (no "МТ1", abnormal temperature pa-
rameters, a unit value of GV "N BTCS", etc) program ЖР67 forms GV "PAM
ABN"=1.
In the process of its operation in this fragment RAM Protocol 42 executes
connection of program А11 inputs to carry out:
- test of "Pamela" RH/BCtS communication channel (DTL А),
- issue of MCMD "Time synchronization", "Mode selection" with an at-
tribute of TRD purge inhibition, "Pamela" RH test”,
- debugging test of MCMD "Lock the transmitter" and MCMD "Unlock
the transmitter" by the Terminal,
- request of the status word of the hardware after it was subjected to some
activities.
RAM Protocol 42 also forms the following signals:
"МТ1" – in case of “on” condition of "ПИ КТП" indicator during timing;
"МТ2" – in case of no “on” condition of "ПИ КТП" indicator during tim-
ing;
"МТ3" – if "Pamela" RH status word with zero positions is available;
"МТ4" – if "Pamela" RH status word with nonzero bits is available or mal-
function of terminal during verification of debugging of MCMD "Lock/unlock the
receiver-transmitter" .
Verification of debugging of MCMD "Lock/unlock the receiver-
transmitter" by the Terminal is performed in the following order:
1) MCMD "Lock the transmitter" is issued to the hardware through DTL A
and this command causes DTL B receiver-transmitter to be locked;
2) After that RAM Terminal42 sets DTL A fault sign to "1" (GV
"КДСПЛ2" [1]=1) and activates input 16 of program А11 where MCL
exchange being executed. The exchange is started by DTL B and is not
353П-46КС-27895-1105 17
executed (no OS) as DTL B receiver-transmitter is locked. Program
A11 forms coded CD А11-0=448 and =638;
3) Then after zeroing the anomaly flag of DTL1 A (КДСПЛ2[1]=0) RAM
Program 42 issues MCMD "Unlock the transmitter" to Pamela through
DTL A, zeroizes GV "НРЛПИБ" (70411[2]=0), sets КДСПЛ2[1] into
“1” and activates input 16 of program А11 where DTL B exchange is
completed normally and program А11 forms coded CD А11-0=0;
4) After that RAM Protocol 42 through DTL B it issues MCMD "Lock the
transmitter" to Pamela and the command causes DTL A transmitter to
be locked;
5) Then RAM Protocol 42 sets DTL A fault attribute to "0" (GV
"КДСПЛ2" [1]=0) and activates input 16 of program А11 where MCL
exchange being executed again. As DTL A receiver-transmitter is
locked, the exchange is not executed (no OS), program А11 forms
coded CD А11-0=208 and goes to DTL B where the exchange is com-
pleted nominally;
6) Then RAM Protocol 42 issues MCMD "Unlock the transmitter" by DTL
B;
7) After that RAM Protocol 42 zeroes DTL A exchange impossibility at-
tribute for program А11 (GV "НРЛПИА" (70412[9]=0) and activates
program А11 by entry 16. DTL A exchange is executed nominally
(coded CD А11-0=0).
Controlling the status word (StW) RAM Protocol 42 executes the follow-
ing: it issues MCMD “OFF GS” if "УНН" parameter (positions 1-4) =1 or 2, if the
value =1 for positions 11, 12, 13 it activates program А11 by input 13 for emer-
gency deactivation of "Pamela" RH.
In fragment 1 RAM Protocol 42 forms the following ID for program А11
and the hardware:
353П-46КС-27895-1105 18
-GV “ВРИСПП”=1,
- MCMD "Mode selection";
- MCMD "RH test".
MCMD data is given in table 2.
For activations 3 and 4:
GV ”ЗВРПК“=1,
GV ”БЛПГК”=0,
GV ”БЛПАМ”=0,
GV “БЛГС”=1,
GV “ВРБУЗП”=1,
GV 'КДБЗ'=528,
GV “НРНД”=0,
GV: “ВРНИЗН”, “ВРВЫСН”=1,
GV “ВРИСПП”=0,
GV “СЧПРПО”=0,
GV “КДМАСК”=0.
All commands sent to the hardware in the first fragment of PAM TA are
given in table 1.
Table 1
Command type Command name The command issue time The com-
mand issue
place
The first activation (in Еок1 and first BTCS channel)
СС "Pam power bus
connection"
at time synchronization - t0 ЖР67
СС "PSCU ON MAIN" 230 s +t0 ЖР67
TLM request for StatusW 350 s +t0 А11
1 data transmission line
353П-46КС-27895-1105 19
Command type Command name The command issue time The com-
mand issue
place
CC "GAS ENABLE" 352 s +t0 ЖР67
"Checkout of interaction between Pamela and BCtS via MCL"
TLM issue of 32 test data
words
355 s +t0 А11
TLM pick-up of 32 test
data words
А11
MCMD "Transmit reply
word"
А11
TLM request for StatusW 357 s +t0 А11
MCMD
№1
"Time Sync" 365 s +t0 А11
TLM request for StatusW 367 s +t0 А11
MCMD
№2
"Select Mode" 375 s +t0 А11
TLM request for StatusW 377 s +t0 А11
CC "IPM1 ON" 385 s +t0 ЖР67
CC "IPM3 ON" 385 s 200 ms +t0 ЖР67
CC "IPM5 ON" 385 s 400 ms +t0 ЖР67
TLM request for StatusW 387 s +t0 А11
TLM request for StatusW 537 s +t0 А11
CC "ND power bus
connection"
10 min +t0 ЖР67
CC "ND ON" 11 min +t0 ЖР67
CC "ND low main volt-
age"
12 min +t0 ЖР67
353П-46КС-27895-1105 20
Command type Command name The command issue time The com-
mand issue
place
CC " ND high main
voltage""
13 min +t0 ЖР67
CC "PSCU reset" 14 min +t0 ЖР67
CC "Safe mode on" 15 min +t0 ЖР67
CC " Safe mode off" 16 min +t0 ЖР67
Nominal deactivation
MCMD "Select Mode" 17 min +t0 А11
TLM request for StatusW 17 min 1s +t0 А11
MCMD " Select Mode " 17 min 2s +t0 А11
TLM request for StatusW 17 min 3s +t0 А11
TLM request for StatusW 17 min 33s +t0 А11
CC "IPM 1,2 OFF" 17 min 34s +t0 А11
CC "IPM 3,4 OFF " А11
CC "IPM 5,6 OFF " А11
CC "PSCU OFF" А11
CC "ND OFF" А11
CC "GAS OFF" А11
CC "Waiting Mode On" А11
CC "ND power bus dis-
connection"
А11
CC "Pam power bus
disconnection"
А11
CC “GS stand-by off” 18min +t0 ЖР67
CC “GS stand-by on” 18 min 20s +t0 ЖР67
353П-46КС-27895-1105 21
Command type Command name The command issue time The com-
mand issue
place
The second activation (in Еок2 and first BTCS channel)
CC "Pam power bus
connection"
at the time of time sync - t0 ЖР67
CC "PSCU ON MAIN" 230 s +t0 ЖР67
TLM request for StatusW 350 s +t0 А11
СС "GAS ENABLE" 352 s +t0 ЖР67
"Checkout of interaction between Pamela and BCtS via MCL"
TLM issue of 32 test data
words
355 s +t0 А11
TLM pick-up of 32 test
data words
А11
MCMD "Transmit reply
word"
А11
TLM request for StatusW 357 s +t0 А11
MCMD "Time Sync" 365 s +t0 А11
TLM request for StatusW 367 s +t0 А11
MCMD "Select Mode" 375 s +t0 А11
TLM request for StatusW 377 s +t0 А11
CC "IPM1 ON" 385 s +t0 ЖР67
CC "IPM3 ON" 385 s 200 ms +t0 ЖР67
CC "IPM5 ON" 385 s 400 ms +t0 ЖР67
TLM request for StatusW 387 s +t0 А11
TLM request for StatusW 537 s +t0 А11
CC "ND power bus
connection"
10 min +t0 ЖР67
353П-46КС-27895-1105 22
Command type Command name The command issue time The com-
mand issue
place
CC "ND ON" 11 min +t0 ЖР67
CC "ND low main volt-
age"
12 min +t0 ЖР67
CC " ND high main
voltage""
13 min +t0 ЖР67
CC "PSCU reset" 14 min +t0 ЖР67
CC "Safe mode on" 15 min +t0 ЖР67
CC " Safe mode off" 16 min +t0 ЖР67
Test of the terminal debugging of MCMD "Lock the transmitter",
"Unlock the transmitter".
MCMD "Lock the transmit-
ter" (on DTL B)
17 min +t0 RAM pro-
gram 42
Test of the terminal debugging of MCMD "Lock the transmitter",
"Unlock the transmitter".
MCMD "Unlock the trans-
mitter" (on DTL B)
19 min +t0 RAM pro-
gram 42
Test of the terminal debugging of MCMD "Lock the transmitter",
"Unlock the transmitter".
MCMD Lock the transmit-
ter" (on DTL А)
21 min +t0 RAM pro-
gram 42
Test of the terminal debugging of MCMD "Lock the transmitter",
"Unlock the transmitter".
MCMD "Unlock the trans-
mitter" (on DTL А)
27 min +t0 RAM pro-
gram 42
353П-46КС-27895-1105 23
Command type Command name The command issue time The com-
mand issue
place
Test of the terminal debugging of MCMD "Lock the transmitter",
"Unlock the transmitter".
Nominal deactivation (see above)
СС “GS stand-by off” 28min +t0 ЖР67
СС “GS stand-by on” 28 min 20s +t0 ЖР67
The third activation of the hardware (in Еок1 and second BTCS channel)
CC "Pamela power bus
connection"
during time sync - t0 A11
CC "PSCU ON
SPARE"
230 s +t0 A11
TLM request for StatusW 350 s +t0 А11
"Checkout of interaction between Pamela and BCtS via MCL"
TLM issue of 32 test data
words
351 s +t0 А11
TLM pick-up of 32 test
data words
А11
MCMD "Transmit reply
word"
А11
MCMD "Time sync" 352 s +t0 А11
TLM request for StatusW 353 s +t0 А11
CC "IPM2 ON" 354 s +t0 A11
CC "IPM4 ON" 354 s 250 ms +t0 A11
CC "IPM6 ON" 354 s 500 ms +t0 A11
TLM request for StatusW 355 s +t0 А11
TLM request for StatusW 506 s +t0 А11
353П-46КС-27895-1105 24
Command type Command name The command issue time The com-
mand issue
place
MCMD "Select Mode" 508 s +t0 А11
TLM request for StatusW 509 s +t0 А11
CC "ND power bus
connection"
А11
CC "ND ON" А11
CC "ND low spare
voltage"
А11
CC "ND high spare
voltage"
А11
Nominal deactivation
The fourth activation (in bus Еок2)
CC "Pam power bus
connection"
в момент синхронизации
времени - t0
ЖР67
CC "PSCU ON
SPARE"
230 s +t0 ЖР67
TLM request for StatusW 350 s +t0 А11
"Checkout of interaction between Pamela and BCtS via MCL"
TLM issue of 32 test data
words
351 s +t0 А11
TLM pick-up of 32 test
data words
А11
MCMD "Transmit reply
word"
А11
MCMD "Time sync" 352 s +t0 А11
TLM request for StatusW 353 s +t0 А11
353П-46КС-27895-1105 25
Command type Command name The command issue time The com-
mand issue
place
CC "IPM 2 ON" 354 s +t0 A11
CC " IPM 4 ON " 354 s 250 ms +t0 A11
CC " IPM 6 ON " 354 s 500 ms +t0 A11
TLM request for StatusW 355 s +t0 А11
TLM request for StatusW 506 s +t0 А11
MCMD "Select Mode" 508 s +t0 А11
TLM request for StatusW 509 s +t0 А11
CC "ND power bus
connection"
A11
CC "ND ON" A11
CC "ND low spare
voltage"
A11
CC "ND high spare
voltage"
A11
Nominal deactivation
MCMD "Select Mode" 35 min +t0 А11
TLM request for StatusW 35 min 1s +t0 А11
MCMD " Select Mode " 35 min 2s +t0 А11
TLM request for StatusW 35 min 3s +t0 А11
TLM request for StatusW 35 min 33s +t0 А11
CC "IPM 1,2 OFF" 35 min 34с +t0 А11
CC "IPM 3,4 OFF " А11
CC "IPM 5,6 OFF " А11
CC "PSCU OFF" А11
CC "ND OFF" А11
353П-46КС-27895-1105 26
Command type Command name The command issue time The com-
mand issue
place
CC "GAS OFF" А11
CC "Waiting Mode On" А11
CC "ND power bus dis-
connection"
А11
CC "Pam power bus
disconnection"
А11
353П-46КС-27895-1105 27
Table 2 MCMD, formed by RAM Protocol 42 for fragment 1 of PAM TA.
MCMD "Select Mode"
16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1
MCMD counter = 0
0 MCMD code = 3316
MCMD length = ?
Time indicator (MSB) = 0
Time indicator (LSB) = 0
0 checksum
MCMD "Pam Test"
16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1
MCMD counter = 0
0 MCMD code = 8F16
MCMD length = 7
Time indicator (MSB) = 0
Time indicator (LSB) = 0
0 checksum
For this fragment "Pamela" RH is activated by CC "ON MAIN PSCU")
from program ПР67, nominal purging of TRD is not executed (for the first and
second activation). For the third and fourth activations Pamela is activated in the
nominal way (by A11 program activation via input 1) with disabling operation
with GS.
"Select Mode"
MCMD data field
"RH" test” MCMD data field
353П-46КС-27895-1105 28
4.1.2 Procedure of PAM TA fragment 2 – "Technological operation".
For this fragment the hardware is activated nominally, the 2, 3 and 6-rd
protection unit, memory module А, standby sources of low and high ND voltage
are ON. A2 operational mode is debugged. The following MCMD are debugged by
the hardware: "PCSU S/W correction", "Memory unload", "History zone reboot".
The time diagram is given in figure 10. Time sync of ground and on-board soft-
ware operation is made in the same way as in item 4.1.1.
In this fragment CD2 shall be taken off with micro OP№*** being pre-
recorded for reading the data array off WM BCtS 510008 address of size 2048 16-
digit words.
RAM Protocol42 forms the following ID necessary for А11 program and
the hardware in this fragment:
- GV "ЗВРПК"=1;
- GV "БЛПГК"=0;
- GV "БЛПАМ"=0;
- GV "ВРБУЗП"=1;
- GV "КДБЗ"=468;
- GV "НРНД"=0;
- GV "ВРНИЗН"=1;
- GV "ВРВЫСН"=1;
- GV "ВРИСПП"=0;
- GV "СЧПРПО"=0;
- GV "КДМАСК"=0;
- GV "БЛГС"=1;
- 2 MCMD "DUMP";
- MCMD "PATCH";
- MCMD "Select Mode";
- MCMD " History zone reboot ".
These MCMD are given in table 3.
353П-46КС-27895-1105 29
Table 3 ID, formed by RAM Protocol42 for fragment 2 of PAM TA.
MCMD "Select Mode" 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1
MCMD counter =0
0 MCMD code =3316
MCMD length = ?
Time indicator (MSB) = 0
Time indicator (LSB) = 0
0 checksum
MCMD "DUMP" 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1
MCMD counter =0
0 MCMD code = 2116
MCMD length =9
Time indicator (MSB) = 0
Time indicator (LSB) = 0
checksum
MCMD "PATCH" 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1
MCMD counter =0
353П-46КС-27895-1105 30
0 MCMD code = 2016
MCMD length = ?
Time indicator (MSB) = 0
Time indicator (LSB) = 0
checksum
MCMD " History zone reboot " 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1
MCMD counter =0
0 MCMD code = 2216
MCMD length = 6
Time indicator (MSB) = 0
Time indicator (LSB) = 0
checksum
Commands sent to the hardware in the second fragment of PAM TA are
given in table 4.
Table 4
Command type Command name The command issue time The com-
mand is-
sue place
"Nominal activation" (with GS operation blocking)
CC "Pamela power
supply connec-
tion"
t0 – time of on-board and
testing program synchroni-
zation
А11
353П-46КС-27895-1105 31
Command type Command name The command issue time The com-
mand is-
sue place
CC "PSCU ON
SPARE"
230 s + t0 А11
TLM request for
StatusW
350 s + t0 А11
"Checkout of in-
teraction between
Pamela and BCtS
via MCL" (see ta-
ble 1)
351 s + t0
MCMD "Time sync" 352 s + t0
TLM request for
statusW
353 s + t0 А11
CC "IPM 2 ON" 354 s + t0 А11
CC "IPM 3 ON" 354 s 250 ms + t0 А11
CC "IPM 6 ON" 354 s 500 ms + t0 А11
TLM request for
statusW
355 s + t0 А11
TLM request for
statusW
506 s + t0 А11
MCMD "Select Mode" 508 s + t0 А11
TLM request for
statusW
509 s + t0 А11
CC "ND power supply
connection"
А11
CC "ND ON" А11
353П-46КС-27895-1105 32
Command type Command name The command issue time The com-
mand is-
sue place
CC "ND low spare
voltage"
А11
CC "ND high spare
voltage"
А11
MCMD
№3
"Select mode" 9 min + t0 А11
MCMD
№4
"DUMP" 10 min + t0 А11
MCMD Recording data af-
ter memory dump
into BCtS RAM
12 min + t0 А11
MCMD
№5
"PATCH" 15 min + t0 А11
MCMD
№6
"DUMP" 18 min + t0 А11
TLM Recording data af-
ter memory dump
into BCtS RAM
19 min + t0 А11
TLM Recording data
from MCMD his-
tory area into
BCtS RAM
22 min + t0 А11
MCMD
№7
"RESET HIS-
TORYAREA"
23 min + t0 А11
353П-46КС-27895-1105 33
Command type Command name The command issue time The com-
mand is-
sue place
TLM Recording data
from MCMD his-
tory area into
BCtS RAM
25 min + t0 А11
"Pamela nominal
switch off" (see
table 1)
40 min + t0 А11
RAM program forms signal "Track mark 3" if MCMD "Reboot MCMD
history area" was performed in the nominal way.
353П-46КС-27895-1105 34
4.1.3 Procedure of PAM TA fragments 3, 4 – "GS test".
The time diagram of the fragments is given in figures 10, 11. Time sync of
ground and on-board software operation is made in the same way as in item 4.1.1.
Fragment 3 is executed both for technological and flight "Pamela" RH pro-
totype.
In this fragment GS is tested for what concerns TRD purging, release of
differential pressure from PC. Fragment 4 is executed with a flight prototype only.
A general nominal purging of TRD is carried out. The duration of this fragment is
about 7 hours. During these hours "Pamela" RH status is under control of nominal
program А11 input 11 (request of the hardware for a status word with 10 sec pe-
riod) and test program ЖР67 input 3 (schematic TM).
For debugging of fragments 3, 4 RAM Protocol 42 forms the following ID:
- GV "ЗВРПК"=1;
- GV "БЛПГК"=0;
- GV "БЛПАМ"=0;
- GV "ВРБУЗП"=0;
- GV "КДБЗ"=158;
- GV "НРНД"=0;
- GV "ВРНИЗН"=0;
- GV "ВРВЫСН"=0;
- GV "ВРИСПП"=0;
- GV "СЧПРПО"=0;
- GV "КДМАСК"=0;
- GV "БЛГС"=0;
- MCMD "TRD purging";
- MCMD "Mode selection";
- MCMD "PC pressure release".
These MCMDs are given in table 5.
353П-46КС-27895-1105 35
Table 5 ID, formed by RAM Protocol 42 for fragments 3, 4 of PAM TA.
MCMD "TRD purging" 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1
MCMD counter =0
0 MCMD code = 3016
MCMD length = 7
Time indicator (MSB) = 0
Time indicator (LSB) = 0
checksum
MCMD "PC pressure release" 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1
MCMD counter =0
0 MCMD code = 3116
MCMD length =7
Time indicator (MSB) = 0
Time indicator (LSB) = 0
checksum
MCMD "Select Mode" 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1
MCMD counter =0
0 MCMD code = 3316
MCMD length =?
Time indicator (MSB) = 0
Time indicator (LSB) = 0
353П-46КС-27895-1105 36
checksum
Commands sent to the hardware in the third fragment of PAM TA are
given in table 6.
Table 6
Command type Command name The command issue time The com-
mand is-
sue place
"Nominal activation"
CC "Pamela power
supply connection"
t0 – time of on-board and
testing program synchroni-
zation
А11
CC "PSCU ON MAIN" 230 s + t0 А11
TLM request for StatusW 350 s + t0 А11
""Checkout of in-
teraction between
Pamela and BCtS
via MCL" (see table
1)
351 s + t0
MCMD "Time sync" 352 s + t0
TLM request for StatusW 353s + t0 А11
CC "IPM 1 ON" 354 s + t0 А11
CC "IPM 3 ON" 354 s 250 мs + t0 А11
CC "IPM 5 ON" 354 s 500 мs + t0 А11
CC "GAS ENABLE" А11
"Select mode" MCMD data area
353П-46КС-27895-1105 37
Command type Command name The command issue time The com-
mand is-
sue place
TLM request for StatusW 355 s + t0 А11
TLM request for StatusW 506 s + t0 А11
MCMD "Select Mode" 508 s + t0 А11
TLM request for StatusW 509 s + t0 А11
CC "ND power supply
connection"
А11
CC "ND ON" А11
CC "ND low main volt-
age"
А11
CC "ND high main
voltage"
А11
MCMD
№8
"TRD purge" 540 s + t0 А11
MCMD
№9
"Select Mode" 1140 s + t0 А11
MCMD
№10
"Pres container
pressure drop start"
1200 s (7 hours 1140s)*+ t0 А11
"Pam. nominal
switch off" (see ta-
ble 1)
1620 s (7 hours 1560s )* +
t0
А11
* Values in parentheses are given for fragment 4.
353П-46КС-27895-1105 38
ЖР67 in.1
Figure 3 Time diagram of PAM TA fragment 1 (beginning)
CC
"R
ESET
PSC
U"
CC
"G
S st
and-
by
OFF
"
CC
"G
S st
and-
by
ON
"
УВИД1=350s+tОШВ
КП6 CC"Еок2 bus
off"
RAM prg. 42
t0=tCTS=0
МТ
t0+230s
PSC
U O
N M
AIN
(PSC
U O
N S
PAR
E)
УВИД2=355s+ tОШВ
А11 inp.16
(test MCL)
GA
S EN
AB
LE
Pam
’s
pow
er
bus c
onne
ctio
n
А36 initiation in input 26
УВИД3=357s+tошв А11 in.p15
(St W)
МТ3
А11 inp.15
(St W)
МТ3
А11 inp. 6
(MCMD "Time sync.")
А11 inp. 6
(MCMD "Seltct Mode")
УВИД4=365s+tошв
IPM
1 (2
) ON
IPM
3(4)
ON
IPM
5(6)
ON
t0+385s
УВИД6=375s+tошв
А11 inp.15
(St W)
МТ3
УВИД5=367s+tошв УВИД8=387s+tошв
А11 inp.15
(St W)
МТ3
УВИД7=377s+tошв
TRD purging inhibit in-
dicator is introduced
А11 inp. 15
(St W)
УВИД9=537s+tошв
А11 in.p15
(St W)
МТ3
УВИД8=387s+tошв
МТ3
t0+352s
МТ1
OP
1-st "Pamela" RH activation
УВИД10=17min+tо
А11 inp.2
deactivation
2s 2s
2s 2c
2s 2s
A40 in.1 УВИД=3s+tОШВ
CC
"N
D p
ower
bus
con
-
nect
ion"
CC
"N
D O
N"
CC
"N
D h
igh
volta
ge m
ain"
CC
"N
D lo
w v
olta
ge m
ain"
CC
"Sa
fe m
ode
on"
CC
"Sa
fe m
ode
off"
t0 +10min t0 +14min t0 +15min t0 +16min t0 +18min t0 +18min 20s
353П-46КС-27895-1105 39
Figure 3 Time diagram of PAM TA fragment 1 (continued)
УВИД2=19 min +tошв УВИД3=21min ы+tошв
А11 in.16
MCL TEST
А11 in.16
MCL TEST
MCMD "Lock the
transmitter"
MCMD "Unlock the
transmitter"
Test of MCMD "Lock the transmitter", "Unlock the transmitter"
by bus B
t0+20min t0+21min t0+22min
CC
"R
ESET
PSC
U"
CC
"SA
FEM
OD
EO
N"
CC
"SA
FE M
OD
E O
FF"
КУ
"Вкл
. Еок
2"
КУ
"Откл.
Еок
1"
Б76 input1
t0+20min t0+21min 60s
t0+23min
2nd activation of
Pamela
УВИД11=23min +tошв
УВИД1=17 min+tошв
353П-46КС-27895-1105 40
Figure 3 Time diagram of PAM TA fragment 1 (continued)
А11 in. 2
off
УВИД4=23 min+tошв УВИД5=27 minт +tошв
А11 in.16
MCL TEST А11 in.16
MCL
MCMD "Lock the
transmitter"
MCMD "Unlock the
transmitter"
Test of MCMD "Locking", "Unlocking" in bus А
353П-46КС-27895-1105 41
+
Figure 3 Time diagram of PAM TA fragment 1 (ending)
БР76 input3 БР76 input 2
3-rd activation of "Pamela" RH
Бр76 input 3
УВИД2=14min+tошв
А11 input 2
deactivation
4-th activation of "Pamela" RH
CC
"O
FF Еок
2"
CC
"O
N Еок
1"
t0+30min 60 sec 60 sec
60 sec
CC
"O
N Еок
2"
t0+15min C
C "
OFF
Еок
1"
t0+16min
t0+31min t0+32min
t0+18min
CC
"G
S
stan
d-by
off
"
CC
"G
S
stan
d-by
on"
t0+28min t0+28min 20s
А11 input 1
А11 input 1
УВИД1=t0+18min
deactivation
А11 in-
put 2
УВИД2=t0+14min
УВИД1=t0+33min
353П-46КС-27895-1105 42
Figure 4 Time diagram of PAM/HSRL TA fragment 5 (beginning).
УВИД4,i=760s+tОШВ
i=1-200
t0=tcts=0
ЖР67 inp.5
А11 inp. 9
MCMD "Orbital
info"
ПрОЗУ 43
МТ
А11 inp.1
Pamela on
УВИД2=600s+tОШВ УВИД3=660s+tОШВ
А11 inp.7
MCMD "inclina-
tion info"
А11 inp.6
MCMD "Time
Sync"
А11 inp.15
ССА request
УВИД5=1360s+tОШВ
МТ3
УВИД6=1400s+tОШВ
А11 inp.6
MCMD to check trigger
УВИ7=8500s+tОШВ
RAM prg13 in.1
УВИ8=8800s+tОШВ
А11 inp10
1st Pam/HSRL download session
УВИ9=9110s+tОШВ
А11 inp.6
MCMD "Select Mode"
УВИ10=9200s+tОШВ
МТ5, computer data: А11-1,
А11-2
УВИ11=9220s+tОШВ
УВИД1=3s+tОШВ
A40 inp.1
353П-46КС-27895-1105 43
Figure 4. Time diagram of PAM/HSRL TA fragment 5 (ending).
Тнм2=17400s+ tОШВ
2nd Pam/HSRL download session
МТ5, computer data: А11-1,
А11-2
УВИ15=17770s+tОШВ
А11 inp.2
Pam switch off
А11 inp.2
УВИ12=9300s+tОШВ
А11 inp1
УВИ13=9900s+tОШВ
А11 inp.6
MCMD to switch on spare electronics
УВИ14=17650s+tОШВ
353П-46КС-27895-1105 44
4.2 Procedure of PAM/HSRL TA.
Before PAM/HSRL TA start ЖР 67 program is activated by input 5 from
the planning program. RAM program 43 is activated immediately after loading the
operational program. Nominal A11 program controls Pamela.
Prior debugging this fragment it is necessary to re-activate HSRL without
warming-up and to initiate BDTS to mode "ЗАП8", ПрБ1. HSRL initiation is re-
corded by tapes of open TM recording.
PAM/HSRL TA consist of 2 fragments: “Nominal operation, checkout of
spare electronics” and “Checkout of connection with HSRL” .
It is possible to debug each fragment separately. The point of fragment de-
bugging is determined by availability of "1" in the bit corresponding to fragment’s
number, GV "VPAMTA" (variant of «Pamela» RH test activations).The distribu-
tion of bits of this variable, its assignment and uplinking of information on the per-
formance of PAM/HSRL TA fragments is analogous to the described under 4.1
and 4.1.1. Before performing fragment 5 it is required to perform fragment 6.
4.2.1 Procedure of PAM/HSRL TA fragment 5 – "Nominal operation,
standby electronics test".
The diagram of debugging this fragment by the hardware is given in Fig 4.
Time sync of ground and on-board software operation is made in the same
way as in item 4.1.1.
"Pamela" RH GSE/HSRL GTE connection diagram is given in Fig 5.
For debugging this fragment of PAM TA it is necessary to connect per-
sonal computer (PC) of "Pamela" RH GSE and HSRL GTE and also to initiate
RAM Protocol 13 input 1 developed by department 1107 from RAM Protocol 43 to
initiate HSRL OBE in due time (not less than 100 sec prior to the first Тнм1-
exchange session).
For this testing fragment "Pamela" RH is activated twice. The first activa-
tion of the hardware is executed by initiation of nominal program А11 in input 1
from RAM Protocol 43 with setting GV "БЛГС (GS disable)"=0. The 1, 4, 6-th
353П-46КС-27895-1105 45
IPMs, memory module А, primary sources of low and high ND voltage are initi-
ated. After nominal activation the hardware is in В4 mode of operation.
After that by consequent initiations of program A11 in inputs 9, 6 RAM
Protocol 43 provides for issue of MCMD: "Orbit information (CMMP)", "Time
synchronization".
Then RAM Protocol 43 provides for transmission of inclination informa-
tion arrays to the hardware within 10 minutes with 3 sec period by repeated initia-
tions of program A11 in input 7 for simulation of similar conditions in the course
of nominal operation of "Pamela" RH.
After that RAM Protocol 43 performs ССА zone request (by initiating pro-
gram А11 in input 15), recording of 12 ССА zone words to BCtS RAM and
"МТ3" signal transmission to GTS RAM via "МТ" channel in case all CCА zone
parameters are normal.
Then RAM Protocol 43 performs testing of trigger system of the first and
second level by issue of MCMD "Select mode"with specific set of parameters.
After that RAM Protocol 43 provides for HSRL exchange session for
transmission of the accumulated scientific data via HSRL OBE and HSRL GTE
commutator to "Pamela" RH GSE for processing and making a conclusion. This
exchange session is carried out using the main exchange adapter in the main data
transmission channel.
Then RAM Protocol 43 by switching program А11 by input 6 provides for
issue of MCMD "Select mode" to Pamela, transmission of computer data arrays
A11-1, A11-2 to GTS RAM and the following (in 20 sec) "Pamela" RH deactiva-
tion (by initiating program А11 in input 2).
After that the second hardware activation is executed in this fragment. It is
also executed by initiation of nominal program А11 in input 1 from RAM Protocol
43. IPMs 2,3,5, memory module A, ND spare high and low voltage supplies are
switched on. After nominal activation the hardware is in В4 mode of operation.
353П-46КС-27895-1105 46
Then RAM Protocol 43 provides for issue of MCMD for connection of
standby electronics.
After that the first and second level triggers are tested in the way, specified
above.
After that RAM Protocol 43 provides for HSRL exchange session for
transmission of the accumulated scientific data via HSRL OBE and HSRL GTE
commutator to "Pamela" RH GSE for processing and concluding.
Then RAM program 43 provides for transmission of computer data arrays
A11-1, A11-2 to GTS RAM. Then nominal "Pamela" RH deactivation is executed
by initiating program А11 in input 2.
For debugging PAM/HSRL TA fragment 5 RAM Protocol 43 forms the
following ID:
- GV "ЗВРПК"=1;
- GV "БЛПГК"=0;
- GV "БЛПАМ"=0;
- GV "БЛГС"=0 for the first activation and =1 for the second activation;
- GV "ВРБУЗП"=0 for the first activation and =1 for the second activa-
tion;
- GV "ВРНИЗН"=0 for the first activation and =1 for the second activa-
tion;
- GV "ВРВЫСН"=0 for the first activation and =1 for the second activa-
tion;
- GV "ВРИСПП"=0;
- GV "СЧПРПО"=0;
- GV "КДМАСК"=0;
- GV "КДБЗ"=518 (for the first activation) and GV "КДБЗ"=268 (for the
second activation);
- GV "НРНД"=0;
- GV "ВРАДАП"=0;
353П-46КС-27895-1105 47
- GV "ВРКАН"=0 for the 1-st exchange session, =1 for the second ex-
change session.
- MCMD "Orbit information (CMMP)";
- MCMD "Inclination data (AP)";
- MCMD "Time synchronization";
- MCMD "Select mode".
These MCMD are given in table 7.
MCMD for activation/deactivation of triggers and initiation of standby
electronics will be given later.
353П-46КС-27895-1105 48
Table 7 MCMD formed by RAM Protocol 43 for PAM/HSRL TA frag-
ment 2.
MCMD " Orbital information"
16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1
MCMD counter = 0
0 MCMD code= Е116
MCMD length = 20
Time tag (MSB) = 0
Time tag (LSB) = 0
1 1 0 0 1 1 0 0 1 1 0 0 1 1 0 0
1 1 0 0 1 1 0 0 1 1 0 0 1 1 0 0
1 1 1 1 1 1 1 1 0 0 0 0 0 0 0 0
0 0 0 0 0 0 0 0 1 1 1 1 1 1 1 1
1 1 1 1 1 1 1 1 0 0 0 0 0 0 0 0
0 0 0 0 0 0 0 0 1 1 1 1 1 1 1 1
1 1 1 1 1 1 1 1 0 0 0 0 0 0 0 0
0 0 0 0 0 0 0 0 1 1 1 1 1 1 1 1
1 1 1 1 1 1 1 1 0 0 0 0 0 0 0 0
0 0 0 0 0 0 0 0 1 1 1 1 1 1 1 1
1 1 1 1 1 1 1 1 0 0 0 0 0 0 0 0
0 0 0 0 0 0 0 0 1 1 1 1 1 1 1 1
1 1 1 1 1 1 1 1 0 0 0 0 0 0 0 0
0 0 0 0 0 0 0 0 1 1 1 1 1 1 1 1
0 checksum
MCMD " Inclination info"
CM
MP
arra
y
353П-46КС-27895-1105 49
16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1
MCMD counter = 0
0 MCMD code = Е216
MCMD length = 66
Time tag (MSB) = 0
Time tag (LSB) = 0
1 0 0 0 0 0 0 0 1 1 0 0 0 0 0 0
0 1 1 0 0 0 0 1 1 1 0 0 0 0 0 0
0 1 1 1 0 0 1 1 1 0 0 0 0 0 0 0
0 0 1 1 1 1 1 1 0 0 0 0 0 0 0 0
0 0 0 1 1 1 1 0 0 0 0 0 0 0 0 0
0 0 0 1 1 1 1 0 0 0 0 0 0 0 0 0
0 0 1 1 1 1 1 1 0 0 0 0 0 0 0 0
0 0 1 1 0 0 1 1 1 0 0 0 0 0 0 0
1 1 1 0 0 0 0 1 1 1 0 0 0 0 0 0
1 1 0 0 0 0 0 0 1 1 1 0 0 0 0 0
inclination info-2 = inclination info-1
inclination info -3 = inclination info -1
inclination info -4 = inclination info -1
inclination info -5 = inclination info -1
inclination info -6 = inclination info -1
0 checksum
MCMD "Time Sync"
16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1
MCMD counter =0
0 MCMD code = Е016
AP-
1 ar
ray
353П-46КС-27895-1105 50
MCMD length = 8
Time tag (MSB) = 0
Time tag (LSB) = 0
ТБШВ
ТБШВ
checksum
MCMD "Select mode"
16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1
MCMD counter=0
0 MCMD code = 3316
MCMD length = ?
Time tag (MSB) = 0
Time tag (LSB) = 0
checksum
All controls issued to the hardware in the first fragment of PAM/HSRL TA
are given in table 8.
353П-46КС-27895-1105 51
Table 8
Control type Control name The control issue time The con-
trol issue
point
"Nominal activation"
CC "Pamela power
supply connec-
tion"
t0 – time of on-board and test-
ing program synchronization
А11
CC "PSCU ON
MAIN"
230 s + t0 А11
TLM request for
status word
350 s + t0 А11
MCMD "Checkout of
Pamela/BCtS
interaction via
MCL" (see table
1)
351 s + t0
MCMD "Time Sync" 352 s + t0
MCMD Request for
Status word
353s + t0 А11
CC "IPM 1 ON" 354 s + t0 А11
CC "IPM 4 ON" 354 s 250 мs + t0 А11
CC "IPM 6 ON" 354 s 500 мs + t0 А11
CC "GAS EN-
ABLE"
А11
MCMD request for
status word
355 s + t0 А11
353П-46КС-27895-1105 52
Control type Control name The control issue time The con-
trol issue
point
MCMD request for
status word
506 s + t0 А11
MCMD "Select Mode" 508 s + t0 А11
MCMD request for
status word
509 s + t0 А11
CC "ND power bus
connection"
А11
CC "ND ON" А11
CC "ND low voltage
main"
А11
CC " ND high volt-
age main"
А11
MCMD
№11
"Orbital infor-
mation"
600 s + t0 А11
MCMD
№12
"Time Sync" 660 s + t0 А11
MCMD
№13
"Inclination in-
formation"
760 s + t0 and further with 3s
period during 10 min
А11
MCMD ССА request 1360 секунд + t0 А11
MCMD
№14
“Select mode”
to check trigger
1400 секунд + t0 А11
First download session
MCMD "Select mode" 8880 секунд + t0 А11
MCMD "Time Sync" А11
MCMD "DOWNLOAD" А11
353П-46КС-27895-1105 53
Control type Control name The control issue time The con-
trol issue
point
MCMD request for CCA А11
MCMD request for CCA 9103 секунды + t0 А11
MCMD
№14а
"Select Mode" 9110 секунд + t0 А11
MCMD Transmission of
computer data
arrays A11-1,
A11-2 to GTC
RAM
9200 секунд + t0 А11
Nominal deacti-
vation (see
tab.1)
9220 секунд + t0 А11
Штатное включение (второе)
CC "Pamela power
supply connec-
tion"
9300 s + t0 А11
CC "PSCU ON
SPARE"
9530 s + t0 А11
TLM request for
status word
9650 s + t0 А11
MCMD "Checkout of
Pamela/BCtS
interaction via
MCL" (see table
1)
9651 s + t0
353П-46КС-27895-1105 54
Control type Control name The control issue time The con-
trol issue
point
MCMD "Time Sync" 9652 s + t0
MCMD request for
status word
9653s + t0 А11
CC "IPM 2 ON" 9654 s + t0 А11
CC "IPM 3 ON" 9654 s 250 мs + t0 А11
CC "IPM 4 ON" 9654 s 500 мs + t0 А11
MCMD request for
status word
9655 s + t0 А11
MCMD request for
status word
9806 s + t0 А11
MCMD "Select Mode" 9808 s + t0 А11
MCMD request for
status word
9809 s + t0 А11
CC "ND power bus
connection"
А11
CC "ND ON" А11
CC "ND low voltage
spare"
А11
CC " ND high volt-
age spare"
А11
MCMD
№15
“Select Mode”
to switch on
spare electronics
9900 s + t0 А11
MCMD
№16
“Select Mode”
to check trigger
10000 s+ t0 А11
353П-46КС-27895-1105 55
Control type Control name The control issue time The con-
trol issue
point
2nd Pam/HSRL download session
MCMD "Select mode" 17380 s + t0 А11
MCMD "Time Sync" А11
MCMD "DOWNLOAD" А11
MCMD request for CCA А11
MCMD request for CCA 17603 s + t0 А11
Transmission of
computer data
arrays A11-1,
A11-2 to GTC
RAM
17650 s + t0
Nominal activa-
tion (see tab. 1)
17700 s + t0 А11
353П-46КС-27895-1105 56
МП2 array formed by RAM Protocol 43 to provide for two exchange ses-
sions is given in table 9.
Table 9
16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 1
ТНОИ(time of interval countdown start)=0 2
КРСР КСН
ПМХСМ
НА
3
НА
2
НА
1
КМАР (number of download sessions)=2 3
НВ (number of orbit) =1 4 ТНСН1 5
//////////////////////// ДЛСН1 6 ТНСН2 7
//////////////////////// ДЛСН2 8 ТНСН3 9
//////////////////////// ДЛСН3 10 ///////////////////////////////////// ПКАС ПД /////////// 11
КПЗВ КПЗН 12
//////////////////
ПРБ
А13
ПРБ
А23
СП3
ПРБ
А12
ПРБ
А22
СП2
ПРБ
А11
ПРБ
А21
СП1 ///// 13
//////////////////////////////////////////////////////////////// НЧК3 НЧК2 НЧК1 14 ПХМ1
16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 00 /////////////////////////////// КМАРР=1 КРНА=1110 1
ДЛМ (duration of download) =200с 2 ТНМ (time of download start)=8900 секунд 3
СДИ* 4 /////////////////////////////////////////////////////////////////////////////////////////////////////// 5
ДЛС 6 ДЛЗНП (ДЛАП2) 7
СПК2 НПК2 (НМП2) СПК1 НПК1 (НМП1) 8 СПК4 НПК4 (НМП4) СПК3 НПК3 (НМП3) 9
////////////////////////////////////////////
ПВКЗУ
ПС /////////// НМВ (number of download in orbit)=1 10
353П-46КС-27895-1105 57
00000 00 0 0 0000000 11
0 0000000 0 0000000 12 С К МЭ Т1 Т2 Т3 /////////// РФСЧ ///////////////////////////////////// 13 КСНР1 КСНВ1 КСНН1 ///// НРЗ1 14 КСНР2 КСНВ2 КСНН2 ///// НРЗ2 15 КСНР3 КСНВ3 КСНН3 ///// НР33 16 КС1 КС2 КС3 /////////////////////////////// РВО 17
ПХМ2 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1
00 /////////////////////////////// КМАРР=1 КРНА=1110 1 ДЛМ (duration of download) =200с 2
ТНМ (time of download start)=17400 секунд 3 СДИ* 4
/////////////////////////////////////////////////////////////////////////////////////////////////////// 5 ДЛС 6
ДЛЗНП (ДЛАП2) 7 СПК2 НПК2 (НМП2) СПК1 НПК1 (НМП1) 8 СПК4 НПК4 (НМП4) СПК3 НПК3 (НМП3) 9
////////////////////////////////////////////
ПВКЗУ
ПС /////////// НМВ (number of download in orbit)==2 10
00000 00 0 0 0000000 11
0 0000000 0 0000000 12 С К МЭ Т1 Т2 Т3 /////////// РФСЧ ///////////////////////////////////// 13 КСНР1 КСНВ1 КСНН1 ///// НРЗ1 14 КСНР2 КСНВ2 КСНН2 ///// НРЗ2 15 КСНР3 КСНВ3 КСНН3 ///// НР33 16 КС1 КС2 КС3 /////////////////////////////// РВО 17
МХСМ
353П-46КС-27895-1105 58
4.2.1.1 Order of gaining information from HSRL GTE.
1) HSRL GTE records (to flight time diagram) information obtained
from technological output of HSRL OBE during PAM/HSRL TA
or from nominal output of HSRL OBE during JO and IT;
2) Information of each recorded route is conversed into a file;
3) After completing PAM TA fragment HSRL GTE converses in-
formation into the original form – information packets at HSRL
OBE input;
4) When the information is conversed HSRL GTE by request of
"Pamela" RH GSE issues information via ЛВС "FAST
EHERNET" at a rate of 100 Мbaud (real transmission rate – 2-5
MB/s). "Pamela" RH GSE request consists in the following:
"Pamela" RH operator opens "Pamela" directory (with conse-
quent opening of all embedded directories) in PC being part of
HSRL GTE and transfers necessary files to PC being part of
"Pamela" RH GSE.
The structure of the information in directory "Pamela" of HSRL GTE PC is
as follows:
- The directory with a number and date of the fragment –
"ФХУ_АБ_ВГ_ДЕ_ЖЗ", where: Ф - fragment,
Х – number of the fragment,
У – sequence number for the fragment
iteration,
АБ – month.
ВГ – date,
ДЕ – hours,
ЖЗ – minutes;
- "MN" directory with the number of the route in this PAM TA fragment,
353П-46КС-27895-1105 59
where М – route, N - № of the route in this fragment,
- "SFI.pam" data file containing packets with scientific information of
"Pamela" RH.
353П-46КС-27895-1105 60
4.2.2 Procedure of PAM/HSRL TA fragment 6 – "Test of HSRL com-munication channels". The time diagram of this fragment is given in Figure 6.
Time sync of ground and on-board software operation is made in the same
way as in item 4.1.1.
"Pamela" RH GSE/HSRL GTE connection diagram is given in Fig 5.
In this fragment RAM Protocol 43 provides for the following activities:
- timely (not less than 100 sec before the beginning of the first Тнм1-
exchange session) initiation of RAM Protocol 13 input 1 for activation
of HSRL OBE,
- the hardware change over to operational mode А0 (by initiating program
А11 in input 6),
- issue of MCMD "BITE" with a test 16-digit word to fill Pamela mem-
ory with test information (by initiating program А11 in input 6),
- issue of MCMD "Select mode" to memorize "prototype" in "Pamela"
RH and to set file-free information pick-up mode (by initiating program
А11 in input 6),
- managing two HSRL exchange sessions (by addressing to program А11
in input 10),
- the hardware change over to operational mode А0 (by initiating pro-
gram А11 in input 6),
- issue of MCMD "Memory configuration" to activate memory module В
(by initiating program А11 in input 6),
- issue of MCMD "BITE" with a test 16-digit word to fill Pamela mem-
ory with test information (by initiating program А11 in input 6),
- issue of MCMD "Select mode" to memorize "prototype" in "Pamela"
RH (by initiating program А11 in input 6),
- managing the third HSRL exchange session,
353П-46КС-27895-1105 61
- issue of MCMD "Memory configuration" to activate memory module
A (by initiating program А11 in input 6),
- "Pamela" RH deactivation by initiating program А11 in input 2.
In the sixth fragment three exchange sessions are provided: with a main
exchange adapter in the main sub-channel №19, with a standby exchange adapter
in the standby sub-channel №19, the third exchange session is executed with a
main adapter in the main exchange channel.
In this fragment memory module A is active during sessions 1, 2 and mem-
ory module B – during session 3.
To perform this test assembly program ПрБ1 and operational mode
"ЗАП8" of BDTS are initiated not late than 1minute prior the first activation of
HSRL.
For debugging of fragment 3 RAM Protocol 42 forms the following ID:
- GV "ЗВРПК"=1;
- GV "БЛПГК"=0;
- GV "БЛПАМ"=0;
- GV ”БЛГС”=1;
- GV "ВРБУЗП"=1;
- GV "ВРНИЗН"=1;
- GV "ВРВЫСН"=1;
- GV "ВРИСПП"=0;
- GV "СЧПРПО"=0;
- GV "КДМАСК"=0;
- GV "КДБЗ"=528;
- GV "ВРКАН"=0 for exchange sessions 1,3 and =1 for session 2;
- GV "ВРАДАП"=0 for exchange sessions 1, 3 and =1 for session 2;
- GV "ВРИОК=1";
- MCMD "Memory configuration";
353П-46КС-27895-1105 62
- MCMD "select mode"(2 types – for change over to mode А0 and for
making the prototype);
- MCMD "BITE";
- МП2 array.
MCMD: "BITE", "Memory configuration", "Select mode" are given in ta-
ble 10.
МП2 array including 3 sub-arrays with route characteristics (one for each
exchange session) is given in table 11.
Figure 5 "Pamela" RH GSE/HSRL OBE GTE connection diagram
"Pamela" RH
ХР5 ХР6
Input com-
mutator
HSRLOB
FTD
(Volume = 20
Gb)
FAST ETHERNET(100 м)
"Pamela" RH
GSE
HSRL GTE
Cable type –
STR categ.5)
353П-46КС-27895-1105 63
Table 10 MCMD, formed by RAM program 43 for fragment 6 of Pamela/
HSRL test activations.
MCMD "Memory configuration" 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1
MCMD counter =0
0 MCMD code =2916
MCMD length =7
Time tag (MSB) = 0
Time tag (LSB) = 0
ПВВМ ПВМП
checksum
ПВМП – memory module selection flag =0, if memory module A is selected, and
=1 if memory module B is selected
ПВВМ – flag of activation/ deactivation of the selected memory module.
Table 10 cont’d.
MCMD "BITE" 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1
MCMD counter =0
0 MCMD code =8016
MCMD length =7
Time tag (MSB) = 0
Time tag (LSB) = 0
1 1 1 0 0 0 1 1 1 0 0 0 1 1 1
checksum
Table 10 cont’d
MCMD "Select Mode"
353П-46КС-27895-1105 64
16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1
MCMD counter =0
0 MCMD code = 3316
MCMD length = ?
Time tag (MSB) = 0
Time tag (LSB) = 0
checksum
Table 10 cont’d.
MCMD "Select Mode"
16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1
MCMD counter =0
0 MCMD code = 3316
MCMD length = ?
Time tag (MSB) = 0
Time tag (LSB) = 0
checksum
Data field
Data field
353П-46КС-27895-1105 65
Table 11
МП2 (1) 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 1
ТНОИ (time of interval countdown start)=0 2
КРСР КСН
ПМХСМ
НА
3
НА
2
НА
1
КМАР (number of download sessions)=2 3
НВ (number of orbit)=3 4 ТНСН1 5
//////////////////////// ДЛСН1 6 ТНСН2 7
//////////////////////// ДЛСН2 8 ТНСН3 9
//////////////////////// ДЛСН3 10 ///////////////////////////////////// ПКАС ПД /////////// 11
КПЗВ КПЗН 12
//////////////////
ПРБ
А13
ПРБ
А23
СП3
ПРБ
А12
ПРБ
А22
СП2
ПРБ
А11
ПРБ
А21
СП1 ///// 13
//////////////////////////////////////////////////////////////// НЧК3 НЧК2 НЧК1 14 ПХМ1
16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 00 /////////////////////////////// КМАРР=1 КРНА=1110 1
ДЛМ (duration of download session)=200s 2 ТНМ (time of download session start)=20min 3
СДИ* 4 /////////////////////////////////////////////////////////////////////////////////////////////////////// 5
ДЛС 6 ДЛЗНП (ДЛАП2) 7
СПК2 НПК2 (НМП2) СПК1 НПК1 (НМП1) 8 СПК4 НПК4 (НМП4) СПК3 НПК3 (НМП3) 9
////////////////////////////////////////////
ПВКЗУ
ПС ///////////НМВ (number of
download session in or-bit) =1
10
00000 00 0 0 0000000 11
0 0000000 0 0000000 12
353П-46КС-27895-1105 66
С К МЭ Т1 Т2 Т3 /////////// РФСЧ ///////////////////////////////////// 13 КСНР1 КСНВ1 КСНН1 ///// НРЗ1 14 КСНР2 КСНВ2 КСНН2 ///// НРЗ2 15 КСНР3 КСНВ3 КСНН3 ///// НР33 16 КС1 КС2 КС3 /////////////////////////////// РВО 17
МХСМ
МП2 (2)
16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 1
ТНОИ (time of interval countdown start)=0 2
КРСР КСН ПМХСМ
НА
3
НА
2
НА
1
КМАР (number of download sessions)=1
НВ (number of orbit)=4 ТНСН1 5
//////////////////////// ДЛСН1 6 ТНСН2 7
//////////////////////// ДЛСН2 8 ТНСН3 9
//////////////////////// ДЛСН3 10 ///////////////////////////////////// ПКАС ПД /////////// 11
КПЗВ КПЗН 12
//////////////////
ПРБ
А13
ПРБ
А23
СП3
ПРБ
А12
ПРБ
А22
СП2
ПРБ
А11
ПРБ
А21
СП1 ///// 13
//////////////////////////////////////////////////////////////// НЧК3 НЧК2 НЧК1 14 ПХМ1
16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 00 /////////////////////////////// КМАРР=1 КРНА=1110 1
ДЛМ (duration of download session)=200s 2 ТНМ (time of download session start)=40min 3
СДИ* 4 /////////////////////////////////////////////////////////////////////////////////////////////////////// 5
ДЛС 6 ДЛЗНП (ДЛАП2) 7
СПК2 НПК2 (НМП2) СПК1 НПК1 (НМП1) 8 СПК4 НПК4 (НМП4) СПК3 НПК3 (НМП3) 9
353П-46КС-27895-1105 67
////////////////////////////////////////////
ПВКЗУ
ПС ///////////НМВ (number of
download session in or-bit) =1
10
00000 00 0 0 0000000 11
0 0000000 0 0000000 12 С К МЭ Т1 Т2 Т3 /////////// РФСЧ ///////////////////////////////////// 13 КСНР1 КСНВ1 КСНН1 ///// НРЗ1 14 КСНР2 КСНВ2 КСНН2 ///// НРЗ2 15 КСНР3 КСНВ3 КСНН3 ///// НР33 16 КС1 КС2 КС3 /////////////////////////////// РВО 17
МХСМ
МП2 (3)
16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 1
ТНОИ (time of interval countdown start)=0 2
КРСР КСН
ПМХСМ
НА
3
НА
2
НА
1
КМАР (number of download sessions)=1
НВ (number of orbit)=5 ТНСН1 5
//////////////////////// ДЛСН1 6 ТНСН2 7
//////////////////////// ДЛСН2 8 ТНСН3 9
//////////////////////// ДЛСН3 10 ///////////////////////////////////// ПКАС ПД /////////// 11
КПЗВ КПЗН 12
//////////////////
ПРБ
А13
ПРБ
А23
СП3
ПРБ
А12
ПРБ
А22
СП2
ПРБ
А11
ПРБ
А21
СП1 ///// 13
//////////////////////////////////////////////////////////////// НЧК3 НЧК2 НЧК1 14 ПХМ1
16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 00 /////////////////////////////// КМАРР=1 КРНА=1110 1
ДЛМ (duration of download session)=200s 2 ТНМ (time of download session start)=72min 3
353П-46КС-27895-1105 68
СДИ* 4 /////////////////////////////////////////////////////////////////////////////////////////////////////// 5
ДЛС 6 ДЛЗНП (ДЛАП2) 7
СПК2 НПК2 (НМП2) СПК1 НПК1 (НМП1) 8 СПК4 НПК4 (НМП4) СПК3 НПК3 (НМП3) 9
////////////////////////////////////////////
ПВКЗУ
ПС ///////////НМВ (number of
download session in or-bit) =1
10
00000 00 0 0 0000000 11
0 0000000 0 0000000 12 С К МЭ Т1 Т2 Т3 /////////// РФСЧ ///////////////////////////////////// 13 КСНР1 КСНВ1 КСНН1 ///// НРЗ1 14 КСНР2 КСНВ2 КСНН2 ///// НРЗ2 15 КСНР3 КСНВ3 КСНН3 ///// НР33 16 КС1 КС2 КС3 /////////////////////////////// РВО 17
МХСМ
Note: Parameters, used by Pamela and HSRL are marked in thick print.
The other parameters will be assigned as zero.
All commands, sent to Pamela during the second fragment of Pam-
ela/HSRL testing activation, are given in Table 12.
Table 12
Type of com-
mand
Name of com-
mand
Time of the command issue Place from
which the
command
is issued.
"Nominal activation"
CC "Pam power
supply connec-
tion"
t0 – time synchronization of
on-board and testing programs
А11
353П-46КС-27895-1105 69
Type of com-
mand
Name of com-
mand
Time of the command issue Place from
which the
command
is issued.
CC "PSCU ON
SPARE"
230 s + t0 А11
MCMD Request status
word
350 s + t0 А11
MCMD "Pamela/BCtS
ineraction via
MCL (see table
1)
351 s + t0
MCMD "Time Sync" 352 s + t0
MCMD Request status
word
353s + t0 А11
CC "IPM 2 ON" 354 s + t0 А11
CC "IPM 4 ON" 354 s 250 мs + t0 А11
CC "IPM 6 ON" 354 s 500 мs + t0 А11
MCMD Request status
word
355 s + t0 А11
MCMD Request status
word
506 s + t0 А11
MCMD "Select Mode" 508 s + t0 А11
MCMD Request status
word
509 s + t0 А11
CC "ND power bus
connection"
А11
CC "ND ON" А11
353П-46КС-27895-1105 70
Type of com-
mand
Name of com-
mand
Time of the command issue Place from
which the
command
is issued.
CC "ND low voltage
spare"
А11
CC ""ND high volt-
age spare""
А11
MCMD
№17
"Select Mode" 540 s + t0 А11
MCMD
№18
"BITE" 570 s + t0 А11
MCMD
№19
"Select Mode" 600 s + t0 А11
1st download session
MCMD "Select Mode" 1180 s + t0 А11
MCMD "Time Sync" А11
MCMD "DOWNLOAD" А11
MCMD Request CCA А11
MCMD Request ССА 1403 s + t0 А11
2nd download session
MCMD "Select Mode" 2380 s + t0 А11
MCMD "Time Sync" А11
MCMD "DOWNLOAD" А11
MCMD Request ССА А11
MCMD Request ССА 2603 s + t0 А11
MCMD
№20
"Select Mode" 3600 s + t0 А11
353П-46КС-27895-1105 71
Type of com-
mand
Name of com-
mand
Time of the command issue Place from
which the
command
is issued.
MCMD
№21
"Memory con-
figuration"
3630 s + t0 А11
MCMD
№22
"BITE" 3660 s + t0 А11
MCMD
№23
"Select Mode" 3690 s + t0 А11
3d download session
MCMD "Select Mode" 4300 s + t0 А11
MCMD "Time Sync" А11
MCMD "DOWNLOAD" А11
MCMD ССА Request А11
MCMD Request ССА 4503 s + t0 А11
MCMD
№24
"Memory con-
figuration"
4620 s + t0 А11
"Nominal deac-
tivation (see ta-
ble 1)
4800 s + t0 А11
Research data are received by Pamela’s GSE according to 4.1.2.1.
353П-46КС-27895-1105 72
Thus during Pamela’s testing activation the following Pamela’s links are
checked: with Resource on-board computer system (by sending MCMD to Pamela
both via MCL line A and line B), with HSRL on-board equipment (by performing
five download sessions with the main and spare channels), with BTMS (by check-
ing TM-parameters with reference values), with BTCS (by sending synchrosignals
via channels 1 and 2), with CRPDS (by sending CC via buses Еок1 and Еок2).
Table 13 gives the order of switching between redundant communication
channels of Pamela and BTCS, CRPDS, HSRL on-board equipment.
Table 13
CC name Check in bus Еок1
Check in bus Еок2
Exchange via MCL
bus A
Exchange via MCL
bus В
Cha
nnel
1
of .
BTC
S
Cha
nnel
2
of
BTC
S
1. Main PSCU on
фр.1 ПВПАМ
фр.1 ПВПАМ
\\\\\\\\\\ \\\\\\\\\\\ \\\\\\\\\\\ \\\\\\\\
2. PSCU off frag.1 of
PAM TA
frag.1 of
PAM TA
\\\\\\\\\\ \\\\\\\\\\\ \\\\\\\\\\\ \\\\\\\\
3. Spare PSCU on
frag.1 of
PAM TA
frag.1 of
PAM TA
\\\\\\\\\\ \\\\\\\\\\\ \\\\\\\\\\\ \\\\\\\\
4. PSCU reset frag.1 of
PAM TA
frag.1 of
PAM TA
\\\\\\\\\\ \\\\\\\\\\\ \\\\\\\\\\\ \\\\\\\\
5. IPM 1 on frag.1 of
PAM TA
frag.1 of
PAM TA
\\\\\\\\\\ \\\\\\\\\\\ \\\\\\\\\\\ \\\\\\\\
6. IPM1-2 off frag.1 of
PAM TA
frag.1 of
PAM TA
\\\\\\\\\\ \\\\\\\\\\\ \\\\\\\\\\\ \\\\\\\\
7. IPM 2 on frag.1 of
PAM TA
frag.1 of
PAM TA
\\\\\\\\\\ \\\\\\\\\\\ \\\\\\\\\\\ \\\\\\\\
8. IPM 3 on frag.1 of
PAM TA
frag.1 of
PAM TA
\\\\\\\\\\ \\\\\\\\\\\ \\\\\\\\\\\ \\\\\\\\
9. IPM 3-4 off frag.1 of
PAM TA
frag.1 of
PAM TA
\\\\\\\\\\ \\\\\\\\\\\ \\\\\\\\\\\ \\\\\\\\
353П-46КС-27895-1105 73
CC name Check in bus Еок1
Check in bus Еок2
Exchange via MCL
bus A
Exchange via MCL
bus В
Cha
nnel
1
of .
BTC
S
Cha
nnel
2
of
BTC
S
10. IPM 4 on frag.1 of
PAM TA
frag.1 of
PAM TA
\\\\\\\\\\ \\\\\\\\\\\ \\\\\\\\\\\ \\\\\\\\
11. IPM 5 on frag.1 of
PAM TA
frag.1 of
PAM TA
\\\\\\\\\\ \\\\\\\\\\\ \\\\\\\\\\\ \\\\\\\\
12. IPM 5-6 off frag.1 of
PAM TA
frag.1 of
PAM TA
\\\\\\\\\\ \\\\\\\\\\\ \\\\\\\\\\\ \\\\\\\\
13. IPM 6 on frag.1 of
PAM TA
frag.1 of
PAM TA
\\\\\\\\\\ \\\\\\\\\\\ \\\\\\\\\\\ \\\\\\\\
14. Safe mode on
frag.1 of
PAM TA
frag.1 of
PAM TA
\\\\\\\\\\ \\\\\\\\\\\ \\\\\\\\\\\ \\\\\\\\
15. Safe mode off
frag.1 of
PAM TA
frag.1 of
PAM TA
\\\\\\\\\\ \\\\\\\\\\\ \\\\\\\\\\\ \\\\\\\\
16. ND on frag.1 of
PAM TA
frag.1 of
PAM TA
\\\\\\\\\\ \\\\\\\\\\\ \\\\\\\\\\\ \\\\\\\\
17. ND off frag.1 of
PAM TA
frag.1 of
PAM TA
\\\\\\\\\\ \\\\\\\\\\\ \\\\\\\\\\\ \\\\\\\\
18. ND main high voltage
frag.1 of
PAM TA
frag.1 of
PAM TA
\\\\\\\\\\ \\\\\\\\\\\ \\\\\\\\\\\ \\\\\\\\
19. ND spare high voltage
frag.1 of
PAM TA
frag.1 of
PAM TA
\\\\\\\\\\ \\\\\\\\\\\ \\\\\\\\\\\ \\\\\\\\
20. ND main low voltage
frag.1 of
PAM TA
frag.1 of
PAM TA
\\\\\\\\\\ \\\\\\\\\\\ \\\\\\\\\\\ \\\\\\\\
21. ND spare low voltage
frag.1 of
PAM TA
frag.1 of
PAM TA
\\\\\\\\\\ \\\\\\\\\\\ \\\\\\\\\\\ \\\\\\\\
22. GS on frag.1 of
PAM TA
frag.1 of
PAM TA
\\\\\\\\\\ \\\\\\\\\\\ \\\\\\\\\\\ \\\\\\\\
23. GS off frag.1 of
PAM TA
frag.1 of
PAM TA
\\\\\\\\\\ \\\\\\\\\\\ \\\\\\\\\\\ \\\\\\\\
24. GS enable frag.1 of
PAM TA
frag.1 of
PAM TA
\\\\\\\\\\ \\\\\\\\\\\ \\\\\\\\\\\ \\\\\\\\
353П-46КС-27895-1105 74
CC name Check in bus Еок1
Check in bus Еок2
Exchange via MCL
bus A
Exchange via MCL
bus В
Cha
nnel
1
of .
BTC
S
Cha
nnel
2
of
BTC
S
25.GS disable frag.1 of
PAM TA
frag.1 of
PAM TA
\\\\\\\\\\ \\\\\\\\\\\ \\\\\\\\\\\ \\\\\\\\
26. Pamela power bus on
frag.1 of
PAM TA
frag.1 of
PAM TA
\\\\\\\\\\ \\\\\\\\\\\ \\\\\\\\\\\ \\\\\\\\
27.Pamela power bus off
frag.1 of
PAM TA
frag.1 of
PAM TA
\\\\\\\\\\ \\\\\\\\\\\ \\\\\\\\\\\ \\\\\\\\
28.ND power bus on
frag.1 of
PAM TA
frag.1 of
PAM TA
\\\\\\\\\\ \\\\\\\\\\\ \\\\\\\\\\\ \\\\\\\\
29.ND power bus off
frag.1 of
PAM TA
frag.1 of
PAM TA
\\\\\\\\\\ \\\\\\\\\\\ \\\\\\\\\\\ \\\\\\\\
MCDM \\\\\\\\\\\\\\ \\\\\\\\\\\\\\ frag. 1 of PAM TA2
frag. 1, 2 of PAM
TA
\\\\\\\\\\\\ \\\\\\\\
Synchrosignals \\\\\\\\\\\\\\ \\\\\\\\\\\\\\ \\\\\\\\\\ \\\\\\\\\\\ frag.1 of PAM TA
frag.1,2of
PAM TA
2 TA=Testing activation
353П-46КС-27895-1105 75
CD-computer data
inp.- input
ms-marshrut (route start)
TSD-time scale digitization
Figure 6. Time diagram of fragment 6 of Pamela/HSRL testing switch (beginning)
2nd download
session.
УВИД8=43min20s+ tTSD УВИД9=60min+ tОШВ УВИД10=60min30s+ tОШВ
CDА11-2
УВИД7=23min20s+tОШВ
ЖР67 inp.7
УВИД1=3s+tошв
А11 inp.1 (on.) RAM prg 13,
input 1
УВИД2=8min 30s+ tОШВ
CD
А11-2
УВИД3=9min10s+ tОШВ А11 in.6 (MCMD
"Select Mode")
УВИД4=9min 30s+ tОШВ
A40 inp.
А11 inp.10
МТ
t0+20min Тнм2
t0+21min t0+40min
t0=tTSD=0
А11 inp.6 (MCMD
"BITE")
УВИД5=10min+tTSD УВИД6=15min+ tОШВ А11 вх.6 (MCMD
"Select mode") Тms1
A11 inp.6 (MCMD
"Select Mode")
Transfer into mode
А0
Transfer into mode А0
Making "imitating model"
A11 inp.6 (MCMD
"Config")
Introduction of memory
module B into operation
353П-46КС-27895-1105 76
Figure 6 Time diagram of fragment 6 of Pamela/HSRL testing switch (end).
CD
А11-2
А11 inp.6 (MCMD
"Mem. Config.")
УВИД16=80min+ tОШВ
Making a simulator
3d download session УВИД12=61 min30s+tОШВУВИ11=61 min+ tОШВ
А11 inp.6 (MCMD
"BITE") А11 inp.6 (MCMD
"Select Mode.")
УВИД13=75min20с+ tОШВ
УВИД15=77min+ tОШВ
Introduction of mem. module A
into operation
А11 inp.2
(0ff)
t0 +72min
T download start3
353П-46КС-27895-1105 77
5. Joint Operation of Pamela and HSRL
During this testing phase operation of Pamela and HSRL on-board equip-
ment will be checked when research data (test data) are being downloaded from
Pamela’s memory into the target data memory of HSRL on-board equipment.
Before joint operation HSRL should be re-activated without warming-up.
Joint operation is performed using RAM program 45 " Pamela ‘s control
during download session", ЖP68, RAM program 13 " HSRL on-board equipment
control during download session " and testing program ОР63 of department 1107.
Pamela’s GSE/HSRL testing equipment is given in Fig.12.
Time diagram is given in Materials of electric and diagnostic tests of HSRL
(353П-46КС-23286-1107).
Time sync of ground and on-board software operation is made in the same
way as in item 4.1.1.
Pamela is planned to be switched on by A11 program activation via input
1. After four download sessions Pamela is planned to be switched off by A11 pro-
gram activation via input 2.
The first download session is performed with the main adapter in the main
subchannel #19, the second one is performed with the spare adapter in the spare
subchannel #19.
Before each download session (at least 3 minutes before it starts) RAM
program 43 arranges the issue of "BITE” MCMD with the test 16-bit word by acti-
vation of A11 program via input 6. During joint operation with Pamela RAM pro-
gram 43 forms the following initial data for A11 program:
- GV "ЗВРПК"=1;
- GV "БЛГС"=1
- GV "БЛПГК"=0;
- GV "БЛПАМ"=0;
- GV "ВРБУЗП"=0
- GV "ВРНИЗН"=0
353П-46КС-27895-1105 78
- GV "ВРВЫСН"=0
- GV "ВРИСПП"=0;
- GV "СЧПРПО"=0;
- GV "КДМАСК"=0;
- GV "КДБЗ"=258;
- GV "НРНД"=0;
- GV "ВРКАН"=0 for download session 1 and =1 for download session
2;
- GV "ВРАДАП=0 for download session 1 and =1 for download session
2;
- GV "ВРИОК=1";
- “Select mode” MCMD (to transfer Pamela into the standby mode);
- "BITE" MCMD.
"BITE" MCMD is given in Table 14.
Table 14.
MCMD "BITE" 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1
MCMD counter =0
0 MCMD code =8016
MCMD length =7
Time tag (MSB)=0
Time tag (LSB)=0
checksum
TW1=**********;
TW2=**********;
TW3=**********;
TW4=**********.
Test word (TWi)
353П-46КС-27895-1105 79
RAM program 43 forms Memory array 2 for joint operation.
Table 15 shows memory arrays 2 for joint operation of Pamela and HSRL.
МП2 (1) 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 1
ТНОИ (time of interval countdown start)=0 2
КРСР КСН
ПМХСМ
НА
3
НА
2
НА
1
КМАР (number of download sessions)=1
НВ (number of orbit)=17 ТНСН1 5
//////////////////////// ДЛСН1 6 ТНСН2 7
//////////////////////// ДЛСН2 8 ТНСН3 9
//////////////////////// ДЛСН3 10 ///////////////////////////////////// ПКАС ПД /////////// 11
КПЗВ КПЗН 12
//////////////////
ПРБ
А13
ПРБ
А23
СП3
ПРБ
А12
ПРБ
А22
СП2
ПРБ
А11
ПРБ
А21
СП1 ///// 13
//////////////////////////////////////////////////////////////// НЧК3 НЧК2 НЧК1 14 ПХМ1
16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 00 /////////////////////////////// КМАРР КРНА=1110 1
ДЛМ (duration of download session)=200s 2 ТНМ (time of download start)=900s 3
СДИ* 4 /////////////////////////////////////////////////////////////////////////////////////////////////////// 5
ДЛС 6 ДЛЗНП (ДЛАП2) 7
СПК2 НПК2 (НМП2) СПК1 НПК1 (НМП1) 8 СПК4 НПК4 (НМП4) СПК3 НПК3 (НМП3) 9
////////////////////////////////////////////
ПВКЗУ
ПС ///////////НМВ (number of
download session in or-bit) =1
10
00000 00 0 0 0000000 11
353П-46КС-27895-1105 80
0 0000000 0 0000000 12 С К МЭ Т1 Т2 Т3 /////////// РФСЧ ///////////////////////////////////// 13 КСНР1 КСНВ1 КСНН1 ///// НРЗ1 14 КСНР2 КСНВ2 КСНН2 ///// НРЗ2 15 КСНР3 КСНВ3 КСНН3 ///// НР33 16 КС1 КС2 КС3 /////////////////////////////// РВО 17
МХСМ
МП2 (2)
16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 1
ТНОИ (time of interval countdown start)=0 2
КРСР КСН
ПМХСМ
НА
3
НА
2
НА
1
КМАР (number of download sessions)=1 3
НВ (number of orbit)=18 4 ТНСН1 5
//////////////////////// ДЛСН1 6 ТНСН2 7
//////////////////////// ДЛСН2 8 ТНСН3 9
//////////////////////// ДЛСН3 10 ///////////////////////////////////// ПКАС ПД /////////// 11
КПЗВ КПЗН 12
//////////////////
ПРБ
А13
ПРБ
А23
СП3
ПРБ
А12
ПРБ
А22
СП2
ПРБ
А11
ПРБ
А21
СП1 ///// 13
//////////////////////////////////////////////////////////////// НЧК3 НЧК2 НЧК1 14 ПХМ1
16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 00 /////////////////////////////// КМАРР КРНА=1110 1
ДЛМ (duration of download session)=200s 2 ТНМ (time of download start)=2400s 3
СДИ* 4 /////////////////////////////////////////////////////////////////////////////////////////////////////// 5
ДЛС 6 ДЛЗНП (ДЛАП2) 7
СПК2 НПК2 (НМП2) СПК1 НПК1 (НМП1) 8
353П-46КС-27895-1105 81
СПК4 НПК4 (НМП4) СПК3 НПК3 (НМП3) 9
////////////////////////////////////////////
ПВКЗУ
ПС ///////////НМВ (number of
download session in or-bit) =2
10
00000 00 0 0 0000000 11
0 0000000 0 0000000 12 С К МЭ Т1 Т2 Т3 /////////// РФСЧ ///////////////////////////////////// 13 КСНР1 КСНВ1 КСНН1 ///// НРЗ1 14 КСНР2 КСНВ2 КСНН2 ///// НРЗ2 15 КСНР3 КСНВ3 КСНН3 ///// НР33 16 КС1 КС2 КС3 /////////////////////////////// РВО 17
МХСМ
Note: Parameters, used by Pamela and HSRL, are marked in thick print.
The other parameters will be assigned as “zero”.
All commands, sent to Pamela during joint operation, are given in Table
16.
Table 16. Commands, sent to Pamela during joint operation.
Type of com-
mand
Name of com-
mand
Time of the command issue Place from
where the
command
is issued
"Nominal activation"
CC "Pam power bus
connection"
t0 – time synchronization of
on-board and testing programs
А11
CC "PSCU ON
MAIN"
230 s + t0 А11
MCMD request status
word
350 s + t0 А11
353П-46КС-27895-1105 82
Type of com-
mand
Name of com-
mand
Time of the command issue Place from
where the
command
is issued
MCMD "Checkout of
Pam/HSRL in-
teraction via
MCL" (see table
1)
351 s + t0
MCMD "Time Sync" 352 s + t0
MCMD request status
word
353s + t0 А11
CC "IPM 1 ON" 354 s + t0 А11
CC "IPM 3 ON" 354 s 250 мs + t0 А11
CC "IPM 5 ON" 354 s 500 мs + t0 А11
MCMD request status
word
355 s + t0 А11
MCMD request status
word
506 s + t0 А11
MCMD request status
word
508 s + t0 А11
MCMD request status
word
509 s + t0 А11
CC "MD power
supply bus con-
nection"
А11
CC "ND ON" А11
353П-46КС-27895-1105 83
Type of com-
mand
Name of com-
mand
Time of the command issue Place from
where the
command
is issued
CC "ND low voltage
main"
А11
CC "ND high volt-
age main"
А11
MCMD
№25
"Select Mode" 540 s + t0 А11
MCMD
№26
"Select Mode" 565 s + t0 А11
MCMD
№27
"BITE" 570 s + t0 А11
1st download session
MCMD "Select Mode" 880 s + t0 А11
MCMD "Time Sync" А11
MCMD "DOWNLOAD" А11
MCMD ССА request А11
MCMD ССА request 1103 s + t0 А11
MCMD
№28
"BITE" 1200 s + t0 А11
2nd download session
MCMD "Select Mode" 2380 s + t0 А11
MCMD "Time Sync" А11
MCMD "DOWNLOAD" А11
MCMD ССА request А11
MCMD ССА request 2603 s + t0 А11
353П-46КС-27895-1105 84
Type of com-
mand
Name of com-
mand
Time of the command issue Place from
where the
command
is issued
"Pamela nomi-
nal deactivation"
(see table 1)
4800 s + t0 А11
Research data are received by Pamela’s GSE according to 4.2.1.1, but
HSRL testing equipment takes data from the nominal output of HSRL on-board
equipment.
353П-46КС-27895-1105 85
Pamela
ХР5 ХР6
HSRL OBE FTD
(Size = 20
Gbyte)
100 m
Pamela’s
GSE
HSRL GTE
Figure 7 Layout of Pamela’s GSE and HSRL GTE
during joint operation.
353П-46КС-27895-1105 86
6. INTEGRATED TESTS OF PAMELA
During integrated tests all initial data for Pamela are assigned in the opera-
tional program.
Pamela’s participation in the integrated tests of “Resource-DK” SC implies
the following items:
1) Before the beginning of the first mode Р10 Pamela is switched on
nominally (by activation of A11 program via input 1 from the operational pro-
gram);
2) After finishing the activation process (at least 550 seconds after A11 ac-
tivation via input 1) the following MCMDs are sent to Pamela:
- №29 MCMD “Select Mode” (1) to transfer Pamela into the stand –by
mode (for this purpose MCMD “Select Mode” should be included into RAM
area of A11 program, starting with the GV”MCMD.CODE5”, A11 program
should be activated by input 6),
- №30 “BITE”MCMD to fill Pamela’s memory with test data (for this
purpose MCMD "BITE" should be included into RAM area of A11 program,
starting with the GV ”MCMD.CODE5”, A11 program should be activated by
input 6).
- 10 seconds later №31 MCMD “Select Mode” (2) to make the imitat-
ing model in Pamela’s memory (for this purpose MCMD “Select Mode”
should be included into RAM area of A11 program, starting with the GV
”MCMD.CODE5”, A11 program should be activated by input 6).
3) Between 5 and 10 min later Pamela participates in the first download
session with HSRL OBE in the first mode P10 (by activation of program A11via
input 10 from program Р10), download session lasts 200 seconds;
4) When the first download session is finished (10 seconds later), the fol-
lowing MCMD are sent to Pamela:
- №32 MCMD “Select Mode” (3) to make the imitating model in Pam-
ela’s memory (for this purpose MCMD “Select Mode” should be included into
353П-46КС-27895-1105 87
RAM area of A11 program, starting with the GV ”MCMD.CODE5”, A11 pro-
gram should be activated by input 6).
- 3 min. after the first download session №33 MCMD “Select Mode”
(4) is issued with to transfer Pamela into particle registration mode (for this
purpose MCMD “Select Mode” should be included into RAM area of A11
program, starting with the GV ”MCMD.CODE5”, A11 program should be acti-
vated by input 6).
- 2 to 5 minutes after issue of MCMD according to item 4) №34
MCMD “Select Mode” (5) is issued with the initial data to calibrate Pamela
(for this purpose MCMD “Select Mode” should be included into RAM area of
A11 program, starting with the GV ”MCMD.CODE5”, A11 program should be
activated by input 6).
- 10 seconds later “Calibrate” MCMD №35 is issued (by activation of
A11 program via input 37)
5) Between 1 and 2 hours later Pamela participates in the second
download session with HSRL OBE (in the 3d mode P10), download session
lasts 200 seconds.
6) Pamela is switched off nominally (by activation of program
A11 via input 2 from the operational program).
The following initial data should be formed before A11 program activation
via input 1:
-GV "ЗВРПК"=1;
- GV "ВРБУЗП"=1;
- GV "КДБЗ"=258;
- GV "БЛПАМ"=0;
- GV "ВРНИЗН"=0;
- GV "ВРВЫСН"=0;
- GV "КДМАСК"=0;
- GV "СЧПРПО"=0;
353П-46КС-27895-1105 88
- GV "НРНД"=0;
- GV "БЛГС"=0.
5 “Select Mode” MCMDs, “BITE” MCMD, formed for Pamela during in-
tegrated tests are given in Table 17.
Table 17
MCMD "Select Mode" (1) 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1
MCMD counter=0
0 MCMD code= 3316
MCMD length=?
Time tag (MSB)=0
Time tag (LSB)=0
checksum
MCMD "Select Mode" (2) 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1
MCMD counter=0
0 MCMD code = 3316
MCMD length =?
Time tag (MSB)=0
Time tag (LSB)=0
checksum
MCMD "Select Mode" (3)
353П-46КС-27895-1105 89
16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1
MCMD counter=0
0 MCMD code = 3316
MCMD length =?
Time tag (MSB)=0
Time tag (LSB)=0
checksum
MCMD "Select Mode" (4) 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1
MCMD counter=0
0 MCMD code = 3316
MCMD length =?
Time tag (MSB)=0
Time tag (LSB)=0
checksum
MCMD "Select Mode" (5) 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1
MCMD counter=0
0 MCMD code = 3316
MCMD length =?
Time tag (MSB)=0
Time tag (LSB)=0
353П-46КС-27895-1105 90
checksum
MCMD"BITE" 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1
MCMD counter=0
0 MCMD code=8016
MCMD length =7
Time tag (MSB)=0
Time tag (LSB)=0
checksum
The following initial data should be formed before activation of A11 pro-
gram via input 10 (in the first and the third modes P10):
- GV "ВРКАН"=0;
- GV "ВРАДАП"=0;
- GV "ВРИОК=1".
Subarrays of route (marshrut) characteristics should be formed too with
КРНА (code of Pamela’s operation)=168, marshrut length=200s, time of marshrut
start, number of marshrut (download session) in orbit.
Additions will be put to data of table 17.
ЖР69 testing program should be activated by inputs:
- by input 1 to check Pamela’s temperature parameters. In case of anom-
aly in any of these parameters ЖР69 program forms GV
"ННТМПП"=1 (anomaly in Pamela’s temperature parameters) for the
planning program КР18. Time of ЖР69 program operation by input 1
does not exceed 3 minutes.
Test word
353П-46КС-27895-1105 91
- by inputs 2 and 3 to control Pamela’s switching on and off. Time of
ЖР69 program operation by input 2 does not exceed 10 minutes. Time
of ЖР69 program operation by input 3 does not exceed 1 minute.
- by input 4 for periodic control of Pamela’s status throughout the whole
activation (between modes P10). Time of ЖР69 program operation by
input 4 does not exceed 4 minutes.
Pamela’s GSE receives research data according to 4.2.1.1, but HSRL GTE
takes data from the nominal HSRL output.
353П-46КС-27895-1105 92
7. AMOUNT OF PAMELA’S RETESTING AFTER REPLACEMENT OF
ITS COMPONENTS OR REPLACEMENT OF “RESOURCE DK” SC
SUPPORT SYSTEMS
After replacement of Pamela’s components as well as “Resource DK” SC
systems or units, connected with Pamela, test activation using “Resource DK” SC
support systems should be repeated within the following amount:
- for replacement of on-board computer system, CRPDS, BDTS, BTCS –
fragment 1 of Pamela’s test activation;
- for replacement of HSRL – fragment 6 of Pamela’s test activation with
HSRL;
- for replacement of Pamela’s components – full Pamela’s test activation
and full Pamela’s test activation with HSRL;
353П-46КС-27895-1105 93
8. Estimation of operating time
Automated estimation of Pamela’s operating time in hours is made by signalling
parameter "ПИТ ПАМ" (Pamela’s power supply) by summation of times when
this parameter is in the closed status.
Estimation of the number of Pamela’s activations is also made by signaling
parameter "ПИТ ПАМ" (Pamela’s power supply) by summation of the number of
closures of this parameter.
353П-46КС-27895-1105 94
9. ORDER OF PAMELA’S ACTIVATION, DEACTIVATION AND RE-
SET
Before Pamela’s activation make sure that all Pamela’s connectors are
mated nominally, besides display "PAM CMC" shall be highlighted on the central
operator's desk.
Activation of the hardware during TA with support systems of 'Resource-
DK1" SC (PAM TA and PAM/HSRL TA) and also during JO and IT is executed
by nominal program А11 (except the first two activations of Pamela in fragment
1). Prior to activation of Pamela the following support systems of 'Resource-DK1"
SC shall be connected and ready for work: BCtS, CRPDS, BDTS in modes ЗАП4,
ПрБ1, BTCS, HSRL OBE (if necessary).
Pamela is completely deactivated during nominal operation under CC "OFF
PSCU", issued by program А11.
If emergent deactivation of Pamela is required, the following CC sequence
shall be issued:
"IPM 1-2 off", " IPM 3-4 off", " IPM 5-6 off", "PSCU off", "ND off", "GS
off", "GS stand-by", "ND power bus off", "Pamela’s power bus off".
In emergent power cut off from 'Resource-DK1" SC it is necessary to initi-
ate test program ЖР67 in input 6 after power restoration to issue the above com-
mands. Then work with "Pamela" RH in normal mode of operation.
Initial condition of "Pamela" RH is regarded as its deactivated condition it
is in after nominal deactivation of Pamela. Initial condition of "Pamela" RH pa-
rameters of signal transfer is as follows:
"PAM P"=0, "ND"=0.
353П-46КС-27895-1105 95
353П-46КС-27895-1105 96
SOTC-special one-time command
Figure8 Time diagram of fragment 2 of Pamela’s test activation.
А11 inp. 6
ЖР67 inp.1 t0=tCTS=0
MC
MD
"Se
lect
Mod
e"(А
2)
ЖР67 inp.2
RAM prg 42
МТ
А11 inp.1
Pam in
mode. В4
А11 inp. 6
УВИД1=9 min+tОШВ УВИД2=10min+tОШ УВИД3=15min+tОШВ
MC
MD
"D
UM
P"
MCMD "PATCH" MCMD "DUMP"
УВИД4=18 min +tОШВ УВИД5=19 min +tОШВ УВИД6=20 min +tОШВ
SOTC to downlink
RAM
А11in.15
MC
MD
"R
ESET
HIS
TOR
Y
AR
EA"
А11 inp. 2(0ff)
History area
pick-up
УВИД7=22 min +tОШВ УВИД8=23 min +tОШВ
History area pick-up
А11 inp. 6
А11 inp.6 А11 inp.6 А11 inp.15 А11 inp15
УВИД9=25 min +tОШВ А11 inp.6
А11 inp.15
УВИД10=40 min +tОШВ
РР84 inp.4
t0+18 min ON CF and
establish-
ment of
t0+22min. downlink off
РР84 inp.5
SOTC62 SOTC112
УВИД=3s+tОШВ A40 inp.1
MT3
t0+26min.
353П-46КС-27895-1105 97
Figure 10 Time diagram of fragment 4 of Pamela’s test activation.
ЖР67 inp.3 А11 inp.1 (On)
ПрОЗУ42
МТ УВИД1=3s+tошв
УВИД2=540s+tошв УВИД3=662s+tошв УВИД4=7ч 662s+tошв
А11 inp.6 А11 inp.6
TRD purg-
ing
30s 120s
А0 mode
А11 inp.2
(Off)
Сброс
давлеия
А11 inp.6 420s
УВИД5=7ч1083s+ tошв
ЖР67 inp.3
А11 inp.1 (On)A40 inp.1
МТ
t0=tошв=0
УВИД2=540s+tошв УВИД3=662s+tошв
А11 inp.2
(Off)
УВИД4=724s+tошв
А11 inp.6 А11 inp.6
TRD
purging
PC jettison-
ing
30s 120s
Mode А0
А11 inp.6
420s
60s
УВИД5=1145s+ tошв
Figure 9 Time diagram of fragment 3 of Pamela’s test activation.
УВИД=3s+tошв
ЖР67 inp.1
A40 inp.1
t0=tошв=0
ПрОЗУ 42 ЖР67 inp.1
CC ""GS stand-by on"
(t0+520s)
CC ""GS stand-by on"
(t0+520s)