MARC-3132 Title: Separate element deactivation for thermal and mechanical pass via uactive does not work Product: Marc Siebel CR: Fixed in Release: Marc - 2011 Description ( External ): The option to activate an element thermally but not mechanically via user subroutine uactive did not work correctly. The element was always activated mechanically for this case. MARC-3116 Title: Global remeshing causes the orientation vectors to be reset to original direction Product: Marc Siebel CR: Fixed in Release: Marc - 2011 Description ( External ): In an analysis with global remeshing of solid elements using a specified material orientation, the orientation directions were wrong after remeshing if significant rotation of the model had taken place. MARC-3101 Title: Thermal orthotropy with table give wrong results Product: Marc Siebel CR: Fixed in Release: Marc - 2011 Description ( External ): Orthotropic material data in a pyrolysis analysis were not handled correctly. In effect the material behavior would be isotropic where the first material value of the orthotropic input would define the isotropic material behavior. This error only applies to orthotropic thermal data activated through the THERMO-PORE model definition option. MARC-3086 Title: Tables with four independent variables produce wrong function values. Product: Marc Siebel CR: Fixed in Release: Marc - 2011 Description ( External ):

Transcript of Marc 2011 Closed Defects

Page 1: Marc 2011 Closed Defects

MARC-3132 Title: Separate element deactivation for thermal and mechanical pass via uactive does not work Product: Marc

Siebel CR: Fixed in Release: Marc - 2011 Description ( External ): The option to activate an element thermally but not mechanically via user subroutine uactive did not work correctly. The element was always activated mechanically for this case.

MARC-3116 Title: Global remeshing causes the orientation vectors to be reset to original direction Product: Marc

Siebel CR: Fixed in Release: Marc - 2011 Description ( External ): In an analysis with global remeshing of solid elements using a specified material orientation, the orientation directions were wrong after remeshing if significant rotation of the model had taken place.

MARC-3101 Title: Thermal orthotropy with table give wrong results Product: Marc

Siebel CR: Fixed in Release: Marc - 2011 Description ( External ): Orthotropic material data in a pyrolysis analysis were not handled correctly. In effect the material behavior would be isotropic where the first material value of the orthotropic input would define the isotropic material behavior. This error only applies to orthotropic thermal data activated through the THERMO-PORE model definition option.

MARC-3086 Title: Tables with four independent variables produce wrong function values. Product: Marc

Siebel CR: Fixed in Release: Marc - 2011 Description ( External ):

Page 2: Marc 2011 Closed Defects

A table that uses four independent variables would not produce the correct function values.

MARC-3064 Title: Marc reader of Mentat coredumps when importing dat file with rigid bodies of ITYPE=4. Product: Marc

Siebel CR: Fixed in Release: Marc - 2011 Description ( External ): The Mentat Marc reader could give a program crash when reading a model with a rigid body defined with curves if the analytical surface option was not used.

MARC-3059 Title: Standy problem using DDM in Marc Product: Marc

Siebel CR: Fixed in Release: Marc - 2011 Description ( External ): In a DDM analysis using an adaptive load stepping the job could in some cases hang indefinitely without progress. This would only happen if tables were used for the load time history, and different tables were active in different domains. Only the multiple input file option was affected (domain decomposition in Mentat).

MARC-3057 Title: Convergence instability using Auricchio's material model in Marc Product: Marc

Siebel CR: Fixed in Release: Marc - 2011 Description ( External ): The Auricchio Shape Memory Alloy model could suffer from bad convergence when temperature changes are present. A temperature gradient term was missing in the implementation leading to poor convergence.

MARC-3056 Title: DDM sif job with weld flux data in history definition stops with error Product: Marc

Page 3: Marc 2011 Closed Defects

Siebel CR: Fixed in Release: Marc - 2011 Description ( External ): An analysis using the weld flux option with DDM in single input file mode could in some cases stop with an error even though the corresponding serial run would run correctly.

MARC-3036 Title: orientation option with element 22 goes wrong Product: Marc

Siebel CR: Fixed in Release: Marc - 2011 Description ( External ): The material orientation option to use a coordinate system sometimes produces inaccurate results. The material system was not exactly normalized, which in some cases could produce wrong results.

MARC-3014 Title: RBE2 doesn't work correctly when using "newmark-beta" or "multi-step houbolt" method. Product: Marc

Siebel CR: Fixed in Release: Marc - 2011 Description ( External ): RBE2 does not work well in dynamic transient analysis using Newmark-Beta or Multistep Houbolt operator.

MARC-3005 Title: Core dump message with PARDISO solver activated Product: Marc

Siebel CR: Fixed in Release: Marc - 2011 Description ( External ): If the Pardiso matrix solver is used for a model which is too large for the integer*4 version to handle, then the job could crash due to integer overflow. This is now trapped and an error message is given with a recommendation to use the integer*8 version instead if possible.

Page 4: Marc 2011 Closed Defects

MARC-2995 Title: vswell.f does not work correctly in multi-loadcases Product: Marc

Siebel CR: Fixed in Release: Marc - 2011 Description ( External ): If a creep load case with swelling strain defined by user subroutine vswell.f was followed by a load case without creep then the swelling strain did not remain constant.

MARC-2991 Title: Penetration in near contact model Product: Marc

Siebel CR: Fixed in Release: Marc - 2011 Description ( External ): Possible penetration in normal contact if near contact is also used and if double sided contact search is used. If it happens the following message appears in the output file: "node ... of body ... released from body ... due to a conflict in the constraints for node ... "

MARC-2974 Title: If delayed slide of for contact is much larger than default error tolerance, contact may be

missed. Product: Marc

Siebel CR: Fixed in Release: Marc - 2011 Description ( External ): If in a contact analysis the delayed slide off option is used and it is much larger than the default contact tolerance, then contact between a node and a segment could be missed completely.

MARC-2966 Title: Linear elastic material behaviors are not normal, when Mooney is also used and Large strain,

1 is flagged. Product: Marc

Siebel CR:

Page 5: Marc 2011 Closed Defects

Fixed in Release: Marc - 2011 Description ( External ): Certain combinations of elements and materials would not work correctly. For instance a linear elastic material and a Mooney rubber material for different parts in an analysis would cause the wrong stress measures to be used. Now there is a new automatic option to tell the code to select the best options for all combinations of elements and materials. In Mentat this is now the default for new models. In the Marc input this is flagged with the option LARGE STRA,4.

MARC-2955 Title: Global Stress is zero when using plane stress element with elastomer. Product: Marc

Siebel CR: Fixed in Release: Marc - 2011 Description ( External ): The global stress of a plane stress element with elastomeric material behavior was not computed and therefore remained zero.

MARC-2953 Title: Unable to select table to define temperature as a function of time Product: Marc

Siebel CR: Fixed in Release: Marc - 2011 Description ( External ): If in the menu BOUNDARY CONDITIONS>FIXED TEMPERATURE a TABLE button in the SHELL ELEMENTS menu section was used to open the CURRENTLY DEFINED TABLES pop-up menu, the list of tables shown could be empty, regardless of the number of tables that exist in the model. Only the TABLE button on the first row of this section worked properly. The same problem existed in INITIAL CONDITIONS>TEMPERATURE.

MARC-2946 Title: Undefined Layer Product: Marc

Siebel CR: Fixed in Release: Marc - 2011 Description ( External ): When any post quantity is requested for an element layer number which is not available in the model, Marc would

Page 6: Marc 2011 Closed Defects

either give junk values or crash. Example: If there are 5 layers in the model, and if the user asks for stresses at layer 6, Marc gave junk values or crashed. Now the post quantity with erroneous layer number will be removed from the list of output.

MARC-2945 Title: Layer List Product: Marc

Siebel CR: Fixed in Release: Marc - 2011 Description ( External ): In the menu JOB RESULTS in Mentat, when a layer list had been defined for a selected element quantity, it was not possible to remove layers from that list. The same was true for the menu LOADCASE RESULT QUANTITIES.

MARC-2942 Title: Marc writer doesn't export BEAM SECT option when using element type 79. Product: Marc

Siebel CR: Fixed in Release: Marc - 2011 Description ( External ): Mentat 2010.2 Defect in Marc Input File Writer: An incorrect input file would be created if thin-walled section beams with an open section (element types 77 or 79) were used; the BEAM SECT parameter option would not be written. Workaround for Mentat 2010.2 is to enter the command "*geometry_option section:general" for the related geometric property.

MARC-2931 Title: The load type 3 of pipe elbow element don't work. Product: Marc

Siebel CR: Fixed in Release: Marc - 2011 Description ( External ): The load type 3 of pipe elbow element don't work.

MARC-2930 Title: Nastran export interface in Mentat / gasket material definition is wrong translated

Page 7: Marc 2011 Closed Defects

Product: Marc

Siebel CR: Fixed in Release: Marc - 2011 Description ( External ): Nastran export interface in Mentat / gasket material definition is wrong translated

MARC-2929 Title: Mentat does not import multiple failure criteria defined in the dat file Product: Marc

Siebel CR: Fixed in Release: Marc - 2011 Description ( External ): Mentat does not import multiple failure criteria defined in the dat file

MARC-2926 Title: Glue Contact for rigid and Deformable bodies Product: Marc

Siebel CR: Fixed in Release: Marc - 2011 Description ( External ): Glue Contact for rigid and Deformable bodies are glued and h = 0.0 it is assumed as if the two bodies are in isolation

MARC-2925 Title: Contact Body parameters are not read by Mentat Product: Marc

Siebel CR: Fixed in Release: Marc - 2011 Description ( External ): The Marc input reader in Mentat did not read diffusion properties of contact bodies.

MARC-2924

Page 8: Marc 2011 Closed Defects

Title: Nastran reader imports orientation incorrectly. Product: Marc

Siebel CR: Fixed in Release: Marc - 2011 Description ( External ): The Nastran input reader in Mentat did not read multiple orientation definitions correctly. The first orientation definition was applied to all elements.

MARC-2923 Title: Shear creep strain is wrong with orthotropic materials. Product: Marc

Siebel CR: Fixed in Release: Marc - 2011 Description ( External ): In a creep job using orthotropic material the shear creep strain was not calculated correctly.

MARC-2920 Title: Questionable results in a magnetostatic-structural analysis. Product: Marc

Siebel CR: Fixed in Release: Marc - 2011 Description ( External ): For coupled magnetostatic-structural analyses when the Lorentz force is computed with the virtual work method the minimum element edge length of elements inside body onto which the force is computed was used to compute the delta displacement. Now the minimum element edge length in the entire model is used. This will prevent elements from going inside out. The default for the delta displacement is changed to 0.01 of the smallest edge length and the default for the number of extra layers to be displaced is changed to 0.

MARC-2916 Title: DDM near contact job failed with error Product: Marc

Siebel CR: Fixed in Release: Marc - 2011

Page 9: Marc 2011 Closed Defects

Description ( External ): Possible crash or error exit in near contact analysis with DDM. If job did not crash or gave error exit results were ok.

MARC-2912 Title: Import Material from .mud 2010.2 didn't work Product: Marc

Siebel CR: Fixed in Release: Marc - 2011 Description ( External ): The Mentat command READ MATERIAL (*read_mater) could not read model files written with Mentat 2010.2.0.

MARC-2899 Title: Marc_reader of Mentat imports auto step incorrectly. Product: Marc

Siebel CR: Fixed in Release: Marc - 2011 Description ( External ): The Marc input reader in Mentat did not read AUTO STEP input correctly for dynamic and creep load cases. The new load case in Mentat was always set to static.

MARC-2897 Title: Some post quantities not available element 86. Product: Marc

Siebel CR: Fixed in Release: Marc - 2011 Description ( External ): The post quantities heat flux and temperature gradient were not available for thermal shell element 86. The temperature output using the utility routine ELMVAR was not correct for elements 86, 87 and 88.

MARC-2895 Title: There is different stress intensity factor of crack between isotropic and orthotropic material. Product: Marc

Siebel CR:

Page 10: Marc 2011 Closed Defects

Fixed in Release: Marc - 2011 Description ( External ): The mode separation into stress intensity factors for the LORENZI J-integral option is not supported for 3D orthotropic materials. This is a documented limitation. However, the check in the code for this case was not correct so it would calculate values which would be incorrect. Now no mode separation is done for this case.

MARC-2892 Title: Memory leak when using DMIG's Product: Marc

Siebel CR: Fixed in Release: Marc - 2011 Description ( External ): When using DMIGs in Marc then some dynamic memory was not released leading to an increase of memory for each increment.

MARC-2889 Title: DDM with inserts can be impossible to decompose in 2010.2 Product: Marc

Siebel CR: Fixed in Release: Marc - 2011 Description ( External ): The INSERT option in a DDM analysis required consecutive numbering of nodes and elements. Now general non-consecutive numbering can be used.

MARC-2887 Title: Position control bodies dies doesn't move and grow by auto increment procedure. Product: Marc

Siebel CR: Fixed in Release: Marc - 2011 Description ( External ): With the AUTO INCREMENT procedure it was not possible to have moving or growing rigid contact bodies.

Page 11: Marc 2011 Closed Defects

MARC-2886 Title: Possible Exit 19 in Restart Job using WELD FILL option and DDM Product: Marc

Siebel CR: Fixed in Release: Marc - 2011 Description ( External ): If, in a restart job using WELD FILL and DDM, one domain does not contain any elements for the weld fill then an exit 19 would occur.

MARC-2869 Title: Exit No. 2004 with orientation material for coupled structure & thermal in 2010 Product: Marc

Siebel CR: Fixed in Release: Marc - 2011 Description ( External ): The combination of ablation and material orientation did not work correctly leading to wrong results or a program crash.

MARC-2856 Title: Core dump in restart job if original input had a TABLE with function reference and restart input

file does not have this Product: Marc

Siebel CR: Fixed in Release: Marc - 2011 Description ( External ): There was a problem with restart if the first job had a table defined with an analytical function and the second job (the restarted job) did not use the analysis function. The restart job would give a program crash for this case.

MARC-2854 Title: First J-integral value is different when using position cf. force controlled rigid bodies Product: Marc

Siebel CR: Fixed in Release: Marc - 2011 Description ( External ):

Page 12: Marc 2011 Closed Defects

The symmetry condition for J-integral and VCCT was not always correctly determined for certain combinations of glued contact and prescribed boundary conditions. Now this is done consistently.

MARC-2851 Title: Marc finishes with exit 4001 in thermal - stress analysis. Product: Marc

Siebel CR: Fixed in Release: Marc - 2011 Description ( External ): Stress analysis using post file of previous heat transfer analysis with posr revision 13 gave exit 4001 or crash when stress analysis had deactivated elements.

MARC-2837 Title: Value of post code global stress is incorrect with element type 98. Product: Marc

Siebel CR: Fixed in Release: Marc - 2011 Description ( External ): The output with the post code for global stress was incorrect for beam element 98 (using numerical section integration).

MARC-2832 Title: Entropy of ablation missing Product: Marc

Siebel CR: Fixed in Release: Marc - 2011 Description ( External ): The simplified ablation of the surface energy model definition option was poorly supported. The enthalpy of ablation for the simple model was not being used in the analysis. In the 2011 version this quantity has also been renamed to the energy flux for the combined effect of convection and diffusion (c.f. volume C, surface energy model definition option, data block 7, field 4).

MARC-2822 Title: REZONING + ORIENTATION = incorrect results

Page 13: Marc 2011 Closed Defects

Product: Marc

Siebel CR: Fixed in Release: Marc - 2011 Description ( External ): The old manual rezoning option did not work in combination with the element orientation option. The manual rezoning option was using an old style element storage method which caused this. Now manual rezoning uses the new element storage method and works with material orientation.

MARC-2820 Title: Element 185 Integration point values are wrongly imported Product: Marc

Siebel CR: Fixed in Release: Marc - 2011 Description ( External ): It was difficult to specify a consistent number of layers and integration points for the mechanical element 185 and the thermal element 175 in a coupled analysis or when using PRE STATE.

MARC-2810 Title: Marc crashes during global remeshing Product: Marc

Siebel CR: Fixed in Release: Marc - 2011 Description ( External ): The use of grid forces together with global remeshing may lead to a program crash.

MARC-2804 Title: MARC job E8X30 hangs while using nps=2 Product: Marc

Siebel CR: Fixed in Release: Marc - 2011 Description ( External ): If the glue deactivation option for contact is used in a DDM analysis and the option is active in some but not all domains then the job could hang indefinitely.

Page 14: Marc 2011 Closed Defects

MARC-2801 Title: Some contact nodes are not ou outline faces with 3d model. Product: Marc

Siebel CR: Fixed in Release: Marc - 2011 Description ( External ): The determination of the contact outline (contact segments) was sometimes incorrectly done when collapsed elements were used.

MARC-2796 Title: Weird Results from Cavity Radiation Product: Marc

Siebel CR: Fixed in Release: Marc - 2011 Description ( External ): Added radiation reflection cut-off parameter to control the iterative radiation reflection code. Up to now the reflection code stopped when the remaining energy to be reflected was < 0.001 of the total energy to be reflected. Sometimes this was not accurate enough.

MARC-2781 Title: Problem with axi to 3D in combination with DDM Product: Marc

Siebel CR: Fixed in Release: Marc - 2011 Description ( External ): The mapping of data for axisymmetric to 3D analysis (PRE STATE) was not done correctly for Herrmann elements (elements with a pressure degree of freedom).

MARC-2780 Title: Initial velocity with deformable bodies does not work in conjunction with cyclic symmetry Product: Marc

Siebel CR: Fixed in Release: Marc - 2011

Page 15: Marc 2011 Closed Defects

Description ( External ): Initial Approach in a contact analysis for a deformable body did not work if also CYCLIC SYM option was used.

MARC-2777 Title: Gasket pressure at complete closure sometimes wrong Product: Marc

Siebel CR: Fixed in Release: Marc - 2011 Description ( External ): The gasket pressure at complete closure of the gasket was sometimes not correct due to tolerance issues.

MARC-2764 Title: pre-load on marc generated mnf-files is wrong or missing Product: Marc

Siebel CR: Fixed in Release: Marc - 2011 Description ( External ): The pre-load vector in an mnf-file generated by Marc is incorrect.

MARC-2763 Title: contact with 2 symmetry planes and a flexible body sometimes goes wrong Product: Marc

Siebel CR: Fixed in Release: Marc - 2011 Description ( External ): If in a 3D analysis a node is touching two symmetry surfaces and the patch of a deformable body at the same time, the applied contact constraints may be incorrect.

MARC-2760 Title: incorrect negative temperature found in thermal-mechanical coupling analysis Product: Marc

Page 16: Marc 2011 Closed Defects

Siebel CR: Fixed in Release: Marc - 2011 Description ( External ): In a remeshing job using the multiplicative formulation in a thermo-mechanical analysis, the temperature could incorrectly decrease after remeshing. This was due to extrapolation errors leading to negative incremental plastic strains.

MARC-2752 Title: For large models with multiple element types, a restart run may crash if the non-default post

file revision 13 is used. Product: Marc

Siebel CR: Fixed in Release: Marc - 2011 Description ( External ): For large models with multiple element types, a restart run may crash if the non-default post file revision 13 is used. Use the default post file revision of 12

MARC-2749 Title: Error in thermo-mechanical SMA? Product: Marc

Siebel CR: Fixed in Release: Marc - 2011 Description ( External ): The effective elastic properties of a thermal-mechanical Shape Memory Alloy do not converge to those of martensite for large fractions of martensite.

MARC-2743 Title: Brembo cut-backs Product: Marc

Siebel CR: Fixed in Release: Marc - 2011 Description ( External ): If a contact analysis requires a cut-back during increment 1 and during this increment new nodes come into contact

Page 17: Marc 2011 Closed Defects

with a deformable body, the results may be inaccurate.

MARC-2737 Title: NL Elasticity model not supported by AXIto3D Product: Marc

Siebel CR: Fixed in Release: Marc - 2011 Description ( External ): The PRE STATE option incorrectly blocked the use of NLELAST material models. Now this combination is allowed.

MARC-2730 Title: The Mentat support for these new parameters Fiber volume fraction and Resin density Product: Marc

Siebel CR: Fixed in Release: Marc - 2011 Description ( External ): There is no Mentat support for the fiber volume fraction and resin density in a curing simulation.

MARC-2725 Title: Material orientation is wrong after rotation Product: Marc

Siebel CR: Fixed in Release: Marc - 2011 Description ( External ): The material orientation for continuum elements using the updated Lagrange framework is incorrect if the element rotates. The orientation vector update is one increment behind the deformation update. A workaround is to make sure to use small rotation increments. Shell elements (except solid shells) are correct in this respect.

MARC-2724 Title: UELASTOMER is not called when Mooney material is used with a rebar Product: Marc

Siebel CR: Fixed in Release: Marc - 2011

Page 18: Marc 2011 Closed Defects

Description ( External ): User subroutine uelastomer is not called for rebar elements using a Mooney material.

MARC-2706 Title: Mentat getting crash while removing unused materials Product: Marc

Siebel CR: Fixed in Release: Marc - 2011 Description ( External ): If the current material is unused and the command *remove_unused_maters is invoked, then Mentat may crash.

MARC-2694 Title: Coupled structural magnetostatic job does not converge Product: Marc

Siebel CR: Fixed in Release: Marc - 2011 Description ( External ): A Coupled magnetostatic-structural analysis using the MST method is not converging if the contact body, onto which surface the lorentz force is computed, lays on the outside. This is fixed, but it is not recommended to perform such a simulation; The body used for the MST method should be completely inside the mesh.

MARC-2692 Title: Symmetry action on rbe2 gives duplicate rbe2s Product: Marc

Siebel CR: Fixed in Release: Marc - 2011 Description ( External ): In Mentat, duplicating RBE2's (using *duplicate_rbe2s or *symmetry_rbe2s) may yield multiple RBE2's with the same name.

MARC-2686

Page 19: Marc 2011 Closed Defects

Title: Near contact incorrect - near contact distance is incorrect Product: Marc

Siebel CR: Fixed in Release: Marc - 2011 Description ( External ): The near contact distance (post code 65) may be inaccurate. Moreover, including this post code may increase the total calculation time.

MARC-2685 Title: Mentat post-processing core dump when using track file with DDM Product: Marc

Siebel CR: Fixed in Release: Marc - 2011 Description ( External ): When trying to visualize track point history data obtained using a DDM analysis, Mentat may crash.

MARC-2683 Title: Write restart file at end of load case is not working if load case have only one increment Product: Marc

Siebel CR: Fixed in Release: Marc - 2011 Description ( External ): The restart last option did not write a restart file after a load case with a single increment.

MARC-2676 Title: In magnetostatic-thermal analysis options are missing for contact table Product: Marc

Siebel CR: Fixed in Release: Marc - 2011 Description ( External ): Mentat does not support entering thermal properties in a Contact Table for a magnetostatic-thermal analysis.

Page 20: Marc 2011 Closed Defects

MARC-2671 Title: De-lamination with user elements is impossible. Product: Marc

Siebel CR: Fixed in Release: Marc - 2011 Description ( External ): Interface elements could not be used as user elements. An exit 13 would occur for this case.

MARC-2670 Title: No convergence in magnetostatic-structural VWM and BH Product: Marc

Siebel CR: Fixed in Release: Marc - 2011 Description ( External ): A Coupled magnetostatic-structural analysis using the MST method is not converging if the contact body, onto which surface the lorentz force is computed, lays on the outside. This is fixed, but it is not recommended to perform such a simulation; The body used for the MST method should be completely inside the mesh.

MARC-2669 Title: problem If the retained node of a servo link has a local coordinate system and is in contact Product: Marc

Siebel CR: Fixed in Release: Marc - 2011 Description ( External ): If the retained node of a servo link has a local coordinate system and is in contact with a rigid body, then the results for the servo link were wrong. This was the case both in 2d and 3d

MARC-2648 Title: Incorrect strength ratio for Hashin Fabric failure criterion Product: Marc

Siebel CR: Fixed in Release: Marc - 2011

Page 21: Marc 2011 Closed Defects

Description ( External ): The documentation for the Strength Ratio (SR) for the Hashin Fabric criterion was incorrect. The definition of SR should be SR=1/sqrt(FI).

MARC-2295 Title: DDM with single file input to support node-based COORD SYSTEM and WELD PATH Product: Marc

Siebel CR: 1-288886268 Fixed in Release: Marc - 2011 Description ( External ): DDM option does not support the COORD SYSTEM Option.

MARC-2261 Title: Choice of analysis passes for RBE3 is not available for RBE3 Product: Marc

Siebel CR: 1-21853157 Fixed in Release: Marc - 2011 Description ( External ): Mentat does not support multi-physics passes with RBE3

MARC-2223 Title: Marc doesn't support double side contact of beam element. Product: Marc

Siebel CR: 1-47814641 Fixed in Release: Marc - 2011 Description ( External ): Marc doesn't support double side contact of beam element.

MARC-2179 Title: Modal analysis with pre-state initial condition Product: Marc

Siebel CR: Fixed in Release: Marc - 2011

Page 22: Marc 2011 Closed Defects

Description ( External ): A modal analysis following PRE STATE could not be performed using the Lanczos method.

MARC-2166 Title: Equivalent plastic strain going negative after adaptive remeshing Product: Marc

Siebel CR: Fixed in Release: Marc - 2011 Description ( External ): In an adaptive meshing analysis an exit 9993 may occur if a table is a function of the equivalent plastic strain or equivalent. This is because due to extrapolation the equivalent plastic strain may get slightly negative.

MARC-2156 Title: Marc Input File Reader in Mentat does not translate diffusion material properties Product: Marc

Siebel CR: 1-287045485 Fixed in Release: Marc - 2011 Description ( External ): Mentat 2010.1.0 Defect in Marc Input File Reader: Diffusion material properties were not translated except for the properties in the SOIL model definition option.

MARC-2139 Title: Default option in Mentat leads to slow eigen value analysis job; Marc Write Product: Marc

Siebel CR: M-2718 Fixed in Release: Marc - 2011 Description ( External ): Default option in Mentat leads to slow eigen value analysis job. To improve performance change the 3rd entry of the 2nd line of RECOVER History definition to a zero.

MARC-2131 Title: Issue of with material failure models in mixture materials

Page 23: Marc 2011 Closed Defects

Product: Marc

Siebel CR: 1-74667198 Fixed in Release: Marc - 2011 Description ( External ): The MIXTURE model based on the weighted average of the nonlinear stress- strain curve does not work correctly for failure models.

MARC-2130 Title: Harmonic Dynamic Restart error caused by how Harmonic BCs are written in .DAT file Product: Marc

Siebel CR: 1-77043998 Fixed in Release: Marc - 2011 Description ( External ): If additional boundary conditions in new table format are given during a restart these boundary conditions are ignored.

MARC-2115 Title: Remove limitation in DDM to allow more than one Coordinate option Product: Marc

Siebel CR: 1-81143281 Fixed in Release: Marc - 2011 Description ( External ): Single input file DDM does not support multiple occurrences of COORDINATE or CONNECTIVITY options.

MARC-1922 Title: Element 33 with an orientation. Product: Marc

Siebel CR: 1-239670966 Fixed in Release: Marc - 2011 Description ( External ): If the Multiplicative decomposition formulation is used in the Updated Lagrange framework different quantities in the preferred system (like stresses, elastic strains, orientation vectors) are not computed correctly.

Page 24: Marc 2011 Closed Defects

MARC-1873 Title: Displaying much small entities located far from origin is strange. Product: Marc

Siebel CR: 1-251100141 Fixed in Release: Marc - 2011 Description ( External ): Drawing of very small items located far away from the origin could be inaccurate. This has been fixed in the GDI version on Windows and the X11 version on Linux/Unix. The OpenGL versions on all platforms may still suffer from this inaccuracy. This is purely a display problem. It will not affect the analysis.

MARC-1627 Title: Orientation type Coordinate System using Global system gives error writing input file from

Mentat Product: Marc

Siebel CR: 1-264338907 Fixed in Release: Marc - 2011 Description ( External ): Marc Input File Writer: If an ORIENTATION of type COORDINATE SYSTEM was used but no coordinate system was selected for that ORIENTATION, then the Marc input file writer would generate an error message, even though the ORIENTATIONS menu suggests that in that case the global system is used. The error message has been removed and the global coordinate will be used if no coordinate system has been selected.

MARC-1572 Title: Mentat displays nodes of invisible contact body after rezoning data in post processing. Product: Marc

Siebel CR: 1-266384591 Fixed in Release: Marc - 2011 Description ( External ): If a contact body was made invisible during post-processing of a remeshing analysis, the nodes of that body would become visible again if the user skipped to an increment with a new mesh.

MARC-1545 Title: Mentat does not read in the "Gradually Released Loads" flag (-3) correctly

Page 25: Marc 2011 Closed Defects

Product: Marc

Siebel CR: 1-267270221 Fixed in Release: Marc - 2011 Description ( External ): The Marc input file reader did not support gradual release of loads in new style table input (second field on third data block of the LOADCASE option set to -3).

MARC-1541 Title: Nastran reader does not read local system defined on the GRID card Product: Marc

Siebel CR: 1-267473006 Fixed in Release: Marc - 2011 Description ( External ): Nastran reader does not read local system defined on the 'GRID' card

MARC-1540 Title: Error in LOCAL APAPTIVE with FILMS and TABLE input. Product: Marc

Siebel CR: 1-267524947 Fixed in Release: Marc - 2011 Description ( External ): The results are wrong in a LOCAL ADAPTIVE job where films are used in combination with table input.

MARC-1522 Title: Mentat Error importing Nastran SOL600 with Progressive Failure Product: Marc

Siebel CR: 1-268322311 Fixed in Release: Marc - 2011 Description ( External ): Error importing NASTRAN SOL600 input file into Mentat with Composite and Failure material - MAT8 & MATF

Page 26: Marc 2011 Closed Defects

MARC-1519 Title: Shells with a COMPOSITE material assigned - not plotted as EXPANDED with Thickness &

Offset Product: Marc

Siebel CR: 1-268738926 Fixed in Release: Marc - 2011 Description ( External ): Mentat would not use the total thickness of a composite shell when plotting the elements in expanded mode if the composite layer thicknesses were given as absolute thickness on the composite material. Instead it used the thickness on the geometric property.

MARC-1512 Title: GLUE option not written out for THERMAL CONTACT Product: Marc

Siebel CR: 1-269325173 Fixed in Release: Marc - 2011 Description ( External ): Marc Input File Writer: An incorrect file would be written for non-structural analyses with a thermal, steady state current flow or diffusion pass if for a certain CONTACT TABLE entry the CONTACT TYPE had been set to GLUE.

MARC-1510 Title: Marc flags global rigid plastic flow automatically in the case of using large displacement

update and finite. Product: Marc

Siebel CR: 1-269760158 Fixed in Release: Marc - 2011 Description ( External ): If a Marc model contains a rigid-plastic material (RIGID yield criterion on the ISOTROPIC option), then all other isotropic materials in the model become rigid-plastic too, irrespective of the yield criteria selected for these materials.

MARC-1507 Title: Coordinate system Triad is lost with Animation Product: Marc

Siebel CR: 1-270166931

Page 27: Marc 2011 Closed Defects

Fixed in Release: Marc - 2011 Description ( External ): The triad (the three arrows in the lower right corner that indicate the orientation of the global coordinate system) was not displayed in animations and gif, mpeg and avi movies. The triad can now be activated for animations and movies independently from the model. The ANIMATION and MOVIE menus have been redesigned.

MARC-1504 Title: Edge effect is not working properly for 3D Magnetostatics Product: Marc

Siebel CR: 1-270277511 Fixed in Release: Marc - 2011 Description ( External ): Edge effect is not working properly for 3D Magnetostatics.

MARC-1497 Title: User guide example global-local with shells runs incorrectly Product: Marc

Siebel CR: 1-271008561 Fixed in Release: Marc - 2011 Description ( External ): The global-local User's guide example about the manhole (2.11) gives wrong results

MARC-1494 Title: Mentat running on Linux OS aborts while importing Abaqus input deck Product: Marc

Siebel CR: 1-271092721 Fixed in Release: Marc - 2011 Description ( External ): Mentat running on Linux OS cannot import Abaqus input deck. But Mentat running on WIN/XP OS imports it successfully. This problem occurs in the case that ^M is at end of title line in abaqus input data.

Page 28: Marc 2011 Closed Defects

MARC-1487 Title: Does not work a run_marc.bat from command prompt. Product: Marc

Siebel CR: 1-272231554 Fixed in Release: Marc - 2011 Description ( External ): The command line option run_marc -j job1 could result in the following error: 'C:\test\getarch.bat' is not recognized as an internal or external command, operable program or batch file. error, program \run_marc_read.exe which reads the command line options does not exist

MARC-1484 Title: post code 110 (Inter laminar shear bond index) Product: Marc

Siebel CR: 1-272409322 Fixed in Release: Marc - 2011 Description ( External ): Pre-processing and Post-processing: Marc post file element result quantity Inter-laminar Shear Bond Index (post code 110) was not supported.

MARC-1482 Title: Error message Model is corrupt upon opening a Mentat 2008 or older model file Product: Marc

Siebel CR: 1-272743991 Fixed in Release: Marc - 2011 Description ( External ): Preprocessing: Some model files created with Mentat 2008 or older can't be opened. The messages "Model is corrupt!" and "Bad material uses!" will appear in respectively the dialogue area and the console window. This problem will occur when a model file contains unused materials, which are treated differently from Mentat 2010 on. Workaround for Mentat 2010.1.0 is to open the model file in Mentat 2008, execute the command MATERIAL PROPERTIES>MATERIAL PROPERTIES>REMOVE UNUSED MATERIALS, and save the model file. One can then read it in Mentat 2010.1.0.

Page 29: Marc 2011 Closed Defects

MARC-1473 Title: Coordinate system / transformations updated based upon motion of nodes goes wrong Product: Marc

Siebel CR: 1-275295411 Fixed in Release: Marc - 2011 Description ( External ): If the 'Update with Deformation' option is used for COORDINATE SYSTEMS, the results are wrong, if new table input is used. With this option the orientation of the coordinate system should follow nodes of the mesh which define the coordinate system during deformation.

MARC-1470 Title: 3D Shell Global Remeshing - VCCT - Memory Overwrite error after remesh - WinXP 32-bit Product: Marc

Siebel CR: 1-275363953 Fixed in Release: Marc - 2011 Description ( External ): Marc can crash when remeshing due to crack growth is followed by remeshing for other reasons.

MARC-1469 Title: Error with card UPDATE and rubber elements Product: Marc

Siebel CR: 1-276032049 Fixed in Release: Marc - 2011 Description ( External ): It is not possible to use Herrmann elements in a creep analysis in the updated Lagrange framework even if the material model used for these elements does not have creep properties.

MARC-1464 Title: Quadratic shells are not handled correctly in STS contact. Product: Marc

Siebel CR: 1-276423891 Fixed in Release: Marc - 2011

Page 30: Marc 2011 Closed Defects

Description ( External ): If quadratic shell element 22 is used in a segment-segment contact analysis the results are wrong.

MARC-1463 Title: Pressurized cavity jobs with table input may crash on Win32 Product: Marc

Siebel CR: 1-277241111 Fixed in Release: Marc - 2011 Description ( External ): Marc can crash for examples containing pressurized cavities using table driven input on win32.

MARC-1461 Title: PLOAD4 in combination with "WELD FLUX" gives exit 1004 Product: Marc

Siebel CR: 1-278266744 Fixed in Release: Marc - 2011 Description ( External ): The combination of PLOAD4 and WELD FLUX in one job may give Marc Exit Number 1004.

MARC-1458 Title: Primer example p4.proc results with 2008r1 and 2010 are different from results with 2007r1 Product: Marc

Siebel CR: 1-279308241 Fixed in Release: Marc - 2011 Description ( External ): If the mid node of beam element 76 or 77 is not defined on a straight line between the end nodes of this element, the results will be wrong since the local element directions are incorrectly computed.

MARC-1456 Title: Total Displacement of a node after Remeshing is set to zero Product: Marc

Siebel CR: 1-279334441

Page 31: Marc 2011 Closed Defects

Fixed in Release: Marc - 2011 Description ( External ): The total displacement of a node is set to zero after a rezoning step. Nodal Vector 79 is now available, which contains the total displacement of the structure since the start of the analysis.

MARC-1455 Title: Marc core dumps with decompostion method detect contact. Product: Marc

Siebel CR: 1-280428521 Fixed in Release: Marc - 2011 Description ( External ): Marc may crash if the option "Detect contact during Decomposition" is used for single input DDM.

MARC-1452 Title: MUMPS solver wouldnt solve this problem. Product: Marc

Siebel CR: 1-280997309 Fixed in Release: Marc - 2011 Description ( External ): A non-positive yield stress defined via a table is not protected and may cause the analysis to fail without a clear indication of the source of the problem. Now protection has been added and the analysis will abort with an error message pointing to the incorrect table and the material using this table.

MARC-1449 Title: Marc 2010 fails to run in i8 mode from command shell on Windows Xp 64 bit platform Product: Marc

Siebel CR: 1-281181444 Fixed in Release: Marc - 2011 Description ( External ): Marc does not run in i8 mode from a command shell on Windows XP 64

Page 32: Marc 2011 Closed Defects

MARC-1447 Title: Intersect option does not work with some specific models Product: Marc

Siebel CR: 1-281193521 Fixed in Release: Marc - 2011 Description ( External ): The button to set the relative tolerance (*set_relative_tolerance) was missing from the INTERSECT menu. The parameter is used in the intersection algorithm to decide if two curve segments coincide. When intersecting small curves located far away from the origin, it may be necessary to tighten this tolerance somewhat.

MARC-1446 Title: Incorrect input file written for "map temperature" bc with "Table driven" input Product: Marc

Siebel CR: 1-281294431 Fixed in Release: Marc - 2011 Description ( External ): Mentat 2010.1.0 Defect in the Marc Input File Writer: If a MAP TEMPERATURE boundary condition was selected in the JOBS>PROPERTIES>MAP TEMPERATURE menu and the INPUT STYLE was TABLE-DRIVEN or MULTI-PHYSICS, an incorrect file could be written. Workaround for Mentat 2010.1.0 is to deselect the MAP TEMPERATURE boundary condition in the JOBS>PROPERTIES>INITIAL LOADS menu and the LOADCASE>PROPERTIES>LOADS menu.

MARC-1440 Title: Mentat core dumps whle including curves or orient curves of weld path. Product: Marc

Siebel CR: 1-282052959 Fixed in Release: Marc - 2011 Description ( External ): Preprocessing: If the PATH input method CURVES was selected in the WELD PATHS menu, the program would crash if the list of curves given for the CURVES ADD command (*add_weldpath_curves) consisted of more than 1 curve. Also, if the ORIENTATION input method CURVES was selected in the WELD PATHS menu, the program would crash if the list of curves given for the CURVES ADD command (*add_weldpath_orient_curves) consisted of more than 1 curve.

Page 33: Marc 2011 Closed Defects

MARC-1439 Title: rigid body Product: Marc

Siebel CR: 1-282745219 Fixed in Release: Marc - 2011 Description ( External ): If a rigid body is defined with 2 closed loops, only the first loop is written in the Marc dat file.

MARC-1438 Title: Job is not converged in electro-static phase of coupling analysis by relative check. Product: Marc

Siebel CR: 1-283017968 Fixed in Release: Marc - 2011 Description ( External ): The electrostatic pass of a coupled electrostatic-structural analysis will not converge if the residual charge is less than 1.0d-20 and max reaction charge is greater than 1.0d-20. This can happen if extremely low values for permittivity are used (e.g. when millimeters are used as model dimension).

MARC-1436 Title: Mentat writes post increment card with auto step incorrectly. Product: Marc

Siebel CR: 1-283963789 Fixed in Release: Marc - 2011 Description ( External ): Marc Input File Writer: An incorrect file would be written for a job with a loadcase using the MULTI-CRITERIA stepping procedure, if the option FIXED TIME INTERVALS had been selected in the POST FILE RESULTS section of the LOADCASE RESULTS popup menu, and the option UNCHANGED INCREMENT FREQUENCY had not been set. Note that the latter option is only displayed when INCREMENT FREQUENCY is selected instead of FIXED TIME INTERVALS.

MARC-1435 Title: Control of writing post data at end of load case is incorrect with auto therm. Product: Marc

Siebel CR: 1-284109849 Fixed in Release: Marc - 2011

Page 34: Marc 2011 Closed Defects

Description ( External ): If the AUTO THERM card is located after LOADCASE 1, Marc writes post data every increment, even though the post frequency is defined as a larger number.

MARC-1434 Title: INSERTS with host entities contact bodies Product: Marc

Siebel CR: 1-284234861 Fixed in Release: Marc - 2011 Description ( External ): Mentat 2010.1.0 Defect in Preprocessing: Mentat allowed selecting RIGID and SYMMETRY bodies as HOST ENTITIES in the LINKS>INSERTS>CONTACT BODIES popup menu.

MARC-1432 Title: Curing analysis is not available with composite material shell element. Product: Marc

Siebel CR: 1-284481454 Fixed in Release: Marc - 2011 Description ( External ): A curing analysis gives wrong results for shell elements if composite material is used.

MARC-1422 Title: Restart problem. job behaves different after restart. Product: Marc

Siebel CR: 1-284757504 Fixed in Release: Marc - 2011 Description ( External ): Wrong results occur if a job is restarted in a load case where boundary conditions use the "Position at Activation of BC" as their reference position.

MARC-1419

Page 35: Marc 2011 Closed Defects

Title: Mentat crashes if equation to compute is long Product: Marc

Siebel CR: 1-284867266 Fixed in Release: Marc - 2011 Description ( External ): Mentat could crash if formulas longer 80 characters were used in commands like *calculator, *eval_define, *set_move_formula, *set_move_formulas, *md_table_formula, *set_md_table_formula_v, set_md_table_formula_f. The maximum length of any formula has been increased to 160 characters.

MARC-1416 Title: Question on Composite Curing - check code and input re: Thermal for Resin Heat generation Product: Marc

Siebel CR: 1-284882090 Fixed in Release: Marc - 2011 Description ( External ): In the heat transfer pass of a curing analysis, curing reaction heat flux is calculated using the composite material density instead of resin density. A new input option is provided to allow the user to input resin density, which is currently used in the curing reaction heat flux calculation. The input for CURE RATE Option A (Model 1) is extended with a 4th data block which contains in the following order the resin cure reaction heat Hr, the viber volume fraction Vf, and the resin density rho.

MARC-1415 Title: Model shows Converged Inc.1; Inc.2 takes extremely long time then No Residual Force. No

Disp Inc Product: Marc

Siebel CR: 1-284882165 Fixed in Release: Marc - 2011 Description ( External ): A non-positive yield stress defined via a table is not protected and may cause the analysis to fail without a clear indication of the source of the problem. Now protection has been added and the analysis will abort with an error message pointing to the incorrect table and the material using this table.

Page 36: Marc 2011 Closed Defects

MARC-1407 Title: Superelastic Shape Memory Material Model (Auricchio) - Error with Unloading/Reloading

Behavior Product: Marc

Siebel CR: 1-284973251 Fixed in Release: Marc - 2011 Description ( External ): The mechanical shape memory material model (auricchio's) produces non physical accumulation of strains under partial loading/unload loops.

MARC-1406 Title: Functional volume flux is incorrect with table driven input. Product: Marc

Siebel CR: 1-284996071 Fixed in Release: Marc - 2011 Description ( External ): Boundary condition volume flux (body type 106) is incorrect with table driven input.

MARC-1396 Title: Button of "END LIST" doesnt activate when picking sample points. Product: Marc

Siebel CR: 1-285081183 Fixed in Release: Marc - 2011 Description ( External ): Postprocessing:The button END LIST would be inactive if a command was used that requests a list of sample points. An example is the execution of the command *set_pathplot_path (button SAMPLE POINTS in the PATH PLOT menu) to create a PATH PLOT PATH if the PATH PLOT MODE is set to SAMPLE POINTS and the SAMPLE METHOD is set to LIST.

MARC-1394 Title: error in thermal contact and coupled contact for non-composite shell elements Product: Marc

Siebel CR: 1-285109756 Fixed in Release: Marc - 2011

Page 37: Marc 2011 Closed Defects

Description ( External ): If homogeneous shell elements with linear temperature distribution per layer are used in a contact analysis, the contact conditions are wrong.

MARC-1390 Title: element type 136 Product: Marc

Siebel CR: 1-285154496 Fixed in Release: Marc - 2011 Description ( External ): If the TSHEAR option is used in an analysis with element type 136 or 202 (linear or quadratic penta), the analysis may prematurely abort with exit,13.

MARC-1379 Title: Export Nastran bdf Product: Marc

Siebel CR: 1-285370185 Fixed in Release: Marc - 2011 Description ( External ): Left justify for double precision numbers in nastran bdf files cannot be read by other software like Catia.

MARC-1377 Title: NC Machining Product: Marc

Siebel CR: 1-285370651 Fixed in Release: Marc - 2011 Description ( External ): In a machining analysis, the tool motion output by Marc does not follow the path defined in the APT file; the change in the orientation of the tool in the results output is not consistent with the APT file input.

MARC-1375 Title: Deformation is incorrect after releasing contacts or nodes with auto step procedure.

Page 38: Marc 2011 Closed Defects

Product: Marc

Siebel CR: 1-285520633 Fixed in Release: Marc - 2011 Description ( External ): Deformation is incorrect after releasing contacts or nodes (options RELEASE or RELEASE NODES)with AUTO STEP or AUTO INCREMENT procedure.

MARC-1373 Title: Mentat needs to support force/area separation GUI pick which is greyed out with genuine

quadratic Product: Marc

Siebel CR: 1-285556546 Fixed in Release: Marc - 2011 Description ( External ): In Mentat for stress-based separation FORCE/AREA could not be selected when the model contained quadratic elements. Now Marc will automatically use EXTRAPOLATED STRESSES for quadratic elements in this case.

MARC-1371 Title: Marc core dumps with auto step procedure in ddm mode. Product: Marc

Siebel CR: 1-285580300 Fixed in Release: Marc - 2011 Description ( External ): A crash can occur in DDM if the following conditions are satisfied. The AUTO STEP procedure is used with the MULTI-CRITERIA. The LARGE STRAIN procedure is used. The different domains contain elements which use material properties that will invoke per domain different analysis procedures due to the LARGE STRAIN parameter. So e.g. one domain contains only elastic material and another domain contains only elastic-plastic material.

MARC-1369 Title: Mentat 2010r1 will not restart from a selected t08 file. Get error message that file cant be

found Product: Marc

Siebel CR: 1-285599181 Fixed in Release: Marc - 2011

Page 39: Marc 2011 Closed Defects

Description ( External ): Filenames referenced in MATERIAL PROPERTIES (material database), INTIAL CONDITIONS (post file, initial stress file), BOUNDARY CONDITIONS (post file, glk file), MESH ADAPTIVITY (template file), LOADCASES (cutter file), JOBS (user subroutine file, restart file, viewfactor file, host file, scratch directory, flowline file) were limited to 80 characters. The limit has been increased to 256 characters.

MARC-1367 Title: Mentat does not seem to support the UDAMAG user subroutine Product: Marc

Siebel CR: 1-285615391 Fixed in Release: Marc - 2011 Description ( External ): Mentat 2010.1.0 Defect in Preprocessing: There was no menu support for the two simplified damage models that allow defining the model damage in user subroutine UDAMAG.

MARC-1366 Title: Mentat Orientation by Curve option does not allow Display Orientation in Pre-Processor Product: Marc

Siebel CR: 1-285692944 Fixed in Release: Marc - 2011 Description ( External ): Mentat did not display the orientations in the pre-processing phase when the type CURVES was used. They could only be displayed in the post-processing phase by choosing the appropriate post codes and running the analysis to obtain the post file. Now they can be displayed before running the analysis.

MARC-1365 Title: A bug in PFA with Max Strain criterion and immediate selective stiffness degradation method Product: Marc

Siebel CR: 1-285693441 Fixed in Release: Marc - 2011 Description ( External ): The maximum strain criterion for progressive failure with the immediate reduction option did not give any material degradation. Other combinations were not affected by this defect.

Page 40: Marc 2011 Closed Defects

MARC-1364 Title: Different order of input options AUTO STEP and CONTROL gives different results Product: Marc

Siebel CR: 1-285693481 Fixed in Release: Marc - 2011 Description ( External ): The order in which the input options CONTROL and AUTO STEP were entered could influence the results of an analysis if the maximum number of recycles set in these options would not be the same. Now the value specified by AUTO STEP is used irrespectively of the order in which the options appear in the input file.

MARC-1357 Title: nr state variables cannot be set in mentat for each analysis type Product: Marc

Siebel CR: 1-285837141 Fixed in Release: Marc - 2011 Description ( External ): Mentat 2010.1.0 Defect in Preprocessing: For certain job types, the button STATE VARIABLES was missing from the JOBS>PROPERTIES>JOB PARAMETERS popup menu. This button is used to increase the number of state variables stored at each point of the structure.Workaround for Mentat 2010.1.0 is to enter the correct commands via the keyboard:*job_param state_variables

MARC-1354 Title: Segment-segment contact for axisymmetric structures Product: Marc

Siebel CR: 1-285914344 Fixed in Release: Marc - 2011 Description ( External ): In an axisymmetric analysis using segment-segment contact it was not possible to define a Symmetry Body at r=0 to impose the Ur=0 boundary condition. There were also inaccuracies in the contact pressure distribution over edges with a varying radius, which could be significant if the radius variation was large.

MARC-1353 Title: Failed elements are not deactivated in PFA Product: Marc

Siebel CR: 1-285939129

Page 41: Marc 2011 Closed Defects

Fixed in Release: Marc - 2011 Description ( External ): The number of layers of a shell element with regular material should be odd due to the integration procedure (Simpson's rule). This is automatically enforced in the code, but was accidentally also done for composite materials. The extra layer usually did no harm, but for progressive failure analysis with element deactivation it had the effect that elements were never deactivated if the number of layers were even. Elements are deactivated when all layers have failed, but the erroneous extra layer would never fail since it was not active.

MARC-1349 Title: If element type 47.48.144.166.169 (rebar) are used standalone. large disp is wrong Product: Marc

Siebel CR: 1-285979711 Fixed in Release: Marc - 2011 Description ( External ): If element types 47,48,144,166,169 (all rebar elements) would be used stand-alone in a model without being embedded in their regular counterpart elements the results for LARGE DISP and LARGE STRAIN would be wrong.

MARC-1344 Title: Fluid Thermal only on Old-Style Tables Product: Marc

Siebel CR: 1-286088138 Fixed in Release: Marc - 2011 Description ( External ): A coupled Fluid-Thermal analysis would give different results depending on wheter the table-driven input style or the old input style was being used and gravity loads were present in the model. In the job with the table-driven input style the gravity loads would be lost.

MARC-1325 Title: Mentat writes view factor data in incorrect format. Product: Marc

Siebel CR: 1-286369937 Fixed in Release: Marc - 2011 Description ( External ): The view factors written by Mentat into the view factor file were written in the wrong format.

Page 42: Marc 2011 Closed Defects

MARC-1321 Title: Nastranout crashs with mud that has no element. Product: Marc

Siebel CR: 1-286466041 Fixed in Release: Marc - 2011 Description ( External ): The Nastran input file writer in Mentat would crash if the model had no elements.

MARC-1319 Title: nodal temperature BC does not give right result. Product: Marc

Siebel CR: 1-286508836 Fixed in Release: Marc - 2011 Description ( External ): Wrong results were obtained for Updated Lagrange using multiplicative decomposition (FeFp) when nodal temperatures were specified in a mechanical stress analysis. The problem was seen for 2 cases: (a) when non-zero initial temperatures were specified (b) when point temperatures are specified in conjunction with the old style input format and adaptive stepping.

MARC-1317 Title: Kienematic boundary condition is applyied incorrectly by forcdt in iterative penetration check. Product: Marc

Siebel CR: 1-286595219 Fixed in Release: Marc - 2011 Description ( External ): Kinematics boundary conditions defined in user subroutine FORCDT would be applied incorrectly in a contact analyis using the iterative penetration check process. The applied values would be different depending on wether the table driven or old input style was used and in both case they were incorrect.

MARC-1315 Title: SOIL material and Linear elastic isotropic material in the same model in Mentat v2010 Product: Marc

Siebel CR: 1-286620571 Fixed in Release: Marc - 2011

Page 43: Marc 2011 Closed Defects

Description ( External ): Mentat 2010.1.0 Defect in Preprocessing: When opening a model file created with Mentat 2008 or older containing a DIFFUSION-STRUCTURAL job (f.k.a. SOIL), materials which were not of type SOIL in the old model did not get the region type NO FLUID PHASE. Mentat 2010.1.0 Defect in Marc Input File Reader: For a DIFFUSION-STRUCTURAL analysis (f.k.a. SOIL), materials which were not defined via the model definition option SOIL did not get the region type NO FLUID PHASE.

MARC-1313 Title: Incorrect post file for magneto/struct job with Maxwell Stress Tensor Lorentz Force calculation Product: Marc

Siebel CR: 1-286654571 Fixed in Release: Marc - 2011 Description ( External ): In a coupled magnetostatic-structural analysis the Lorentz force was only written to the postfile when the Maxwell Stress Tensor method was used. Since this method is chosen in a loadcase the postfile did not contain this force in increment zero. Also when for some loadcases the Virtual Work Method method was used the vector would be missing for these loadcase increments. Now the vector is always written when requested irrespective of the method being used. By default, however, this vector is not written, since only the summation of this force over a body has a physical meaning.

MARC-1312 Title: libguide.so Product: Marc

Siebel CR: 1-286690881 Fixed in Release: Marc - 2011 Description ( External ): With HPMPI environment variables would not be passed correctly to all domains in a DDM parallel analysis. It depended on the order of defining the variables RUN_JOB1 and MPIHPSPECIAL. The variable RUN_JOB1 needed to be defined after the variable MPIHPSPECIAL.

MARC-1307 Title: DDM gives different results Product: Marc

Siebel CR: 1-286858483 Fixed in Release: Marc - 2011 Description ( External ):

Page 44: Marc 2011 Closed Defects

In a parallel DDM analysis using the Multifrontal Sparse Direct Solver (solver 8) results could deviate from the results obtained for the same job in a serial run. The deviations can be reduced by using a tighter tolerance on the SOLVER input (e.g. 1.0E-6). On platforms where the Pardiso (solver 11) or the MUMPS (solver 12) solver are available it is recommended to use to these solvers instead. They often are faster than solver 8 and don't show the deviations when comparing results from parallel and serial runs.

MARC-1299 Title: CPU time of Pardiso matrix solver not reported correctly for DDM Product: Marc

Siebel CR: 1-287082246 Fixed in Release: Marc - 2011 Description ( External ): The CPU time of the Pardiso matrix solver would not be reported correctly in a parllel DDM analysis.

MARC-1297 Title: Initial force not taken into account for non-linear springs using stiffness option Product: Marc

Siebel CR: 1-287156891 Fixed in Release: Marc - 2011 Description ( External ): An initial force was not taken into account for non-linear springs using stiffness option.

MARC-1295 Title: Core dump using md_elastomer Product: Marc

Siebel CR: 1-287157739 Fixed in Release: Marc - 2011 Description ( External ): Jobs can potentially crash when using user subroutine MD_UELASTOMER.

MARC-1294 Title: Marc core dumps with local adaptive and visco elastic rubber material. Product: Marc

Siebel CR: 1-287160861

Page 45: Marc 2011 Closed Defects

Fixed in Release: Marc - 2011 Description ( External ): Jobs with local adaptive and visco elastic rubber material crash.

MARC-1293 Title: Cavity edges + cavity element type 171 Product: Marc

Siebel CR: 1-287161021 Fixed in Release: Marc - 2011 Description ( External ): Pressurized cavity jobs with table input may crash on Win32 platforms.

MARC-1292 Title: Error in beam offsets in direction of shell normal Product: Marc

Siebel CR: 1-287190395 Fixed in Release: Marc - 2011 Description ( External ): If beam offsets in the GEOMETRY option are specified in the direction of the shell normal and this is done more than once the analysis results are incorrect.

MARC-1291 Title: Contact friction stresses are not correct for glued shells and segment-segment contact Product: Marc

Siebel CR: 1-287196111 Fixed in Release: Marc - 2011 Description ( External ): Contact friction stresses are not correct for glued shells and segment-segment contact

MARC-1288 Title: Marc process go to sleep on RedHat RHEL 5.2

Page 46: Marc 2011 Closed Defects

Product: Marc

Siebel CR: 1-287290171 Fixed in Release: Marc - 2011 Description ( External ): On Linux 64-bit platform a licensing defect may cause Marc to hang when utilizing a combination of node-locked and network licenses.

MARC-1287 Title: Inconsistent deactivation of elements in a machining analysis Product: Marc

Siebel CR: 1-287293921 Fixed in Release: Marc - 2011 Description ( External ): In a machining analysis, elements that were lying within the cutter path were not all deactivated. In particular this would happen when the cutter had to follow a curved path.

MARC-1286 Title: List of nodes of a DENSITY initial condition not translated by Marc reader Product: Marc

Siebel CR: 1-287311295 Fixed in Release: Marc - 2011 Description ( External ): Mentat 2010.1.0 Defect in Marc Input File Reader: The list of nodes to which a DENSITY initial condition was applied would not be translated. Note that the list of elements of a RELATIVE DENSITY initial condition was translated correctly.

MARC-1285 Title: El-MA transient operator not read from input file Product: Marc

Siebel CR: 1-287311345 Fixed in Release: Marc - 2011 Description ( External ): Mentat 2010.1.0 Defect in Marc Input File Reader: The value of the option TRANSIENT OPERATOR in a magnetodynamic analysis was not translated (Marc parameter option EL-MA). In the resulting job it was always set to the default (NEWMARK-BETA).

Page 47: Marc 2011 Closed Defects

MARC-1284 Title: LOADCASES>ELECTROSTATIC>TYPE>STEADY STATE button issues wrong command Product: Marc

Siebel CR: 1-287339661 Fixed in Release: Marc - 2011 Description ( External ): Mentat 2010.1.0 Defect in Preprocessing: The button STEADY STATE to change the type of the current loadcase to an electrostatic steady state loadcase issued an incorrect command. It first created a new loadcase and subsequently changed the type of that loadcase to an electrostatic steady state loadcase. This button can be accessed in the LOADCASES>TYPE popup menu if the ANALYSIS CLASS filter has been set to ELECTROSTATIC.Workaround for Mentat 2010.1.0 is to enter the correct command via the keyboard:*loadcase_type elsta:steady

MARC-1283 Title: External force of elbow element is incorrect by volumetic load. Product: Marc

Siebel CR: 1-287367084 Fixed in Release: Marc - 2011 Description ( External ): The external equivalent nodal forces by volumetric loads on nodes of element type 31 would be incorrect if the element was being used in combination with other elements that had a different number of coordinates for the nodes (.e.g type 78, which can have 6 coordinates per node, whereas type 31 has 3 coordinates per node).

MARC-1281 Title: Wrong results in modal analysis if lowest frequency is defined Product: Marc

Siebel CR: 1-287494625 Fixed in Release: Marc - 2011 Description ( External ): In rare cases a model with springs or dmigs and tyings/servolinks/rbe's gives wrong eigenvalues in the lanczos procedure if either the lowest or the highest frequency to be extracted is non-zero.

MARC-1279 Title: Default creep testing tolerances Product: Marc

Page 48: Marc 2011 Closed Defects

Siebel CR: 1-287501480 Fixed in Release: Marc - 2011 Description ( External ): Mentat wrote the same convergence criteria values for either relative or absolute creep testing. The default auto creep tolerances on creep strain change and stress change were also inconsistent with the ones documented in volume C when the absolute testing option was used. The tolerances for relative testing were also being used for absolute testing. Absolute testing will now use a default creep strain change of 0.01 and a default stress change of 100.

MARC-1278 Title: nodes are sticking to NURBS curves in contact analysis at span points Product: Marc

Siebel CR: 1-287513789 Fixed in Release: Marc - 2011 Description ( External ): In a contact analysis using NURBS with order (M) and having multiple occurrences of (M-1) knot vectors immediately following each other (e.g. 0 0 0 1 1 2 2 2 2 3 3 4 4 4) the contact could result in incorrect sticking of nodes at the span points.

MARC-1277 Title: Plastic heat generation not working together with remeshing Product: Marc

Siebel CR: 1-287534141 Fixed in Release: Marc - 2011 Description ( External ): Plastic heat generation was not working together with remeshing in coupled thermal/structural analysis.

MARC-1274 Title: Interference direction is incorrect between nurbs curve and nodes in 2d. Product: Marc

Siebel CR: 1-287640844 Fixed in Release: Marc - 2011 Description ( External ): In a two-dimensional contact interference closure analysis the interference direction between a NURBS curve and the nodes would be incorrect. With other types of rigid bodies the direction was correct.

Page 49: Marc 2011 Closed Defects

MARC-1272 Title: In weld modeling the total heat received by the model does not match the applied power Product: Marc

Siebel CR: 1-287648462 Fixed in Release: Marc - 2011 Description ( External ): In a weld modeling analysis using the weld path tool and a volumetric heat flux, the total heat received by the model did not match the applied power.

MARC-1269 Title: Coupled analysis with thick shell (reduced integration - element 140) gives bad results. Product: Marc

Siebel CR: 1-287691090 Fixed in Release: Marc - 2011 Description ( External ): In a coupled thermal-stress analysis the temperature mapping from the fully integrated thermal shell element type 85 to its structural counterpart the reduced integration structural shell element type 140 was incorrect. This could lead to e.g. unsymmetric results where symmetric ones were expected. Mappings between element types 85 and 75 (also fully integrated) were not affected.

MARC-1267 Title: Incorrect strain energy density and equivalent elastic strain Product: Marc

Siebel CR: 1-287721501 Fixed in Release: Marc - 2011 Description ( External ): The calculated strain energy density for Mooney materials was incorrect when the strain energy function had a non-zero C30 coefficient.

MARC-1265 Title: Global creep strain tensor is always 0.0 with shell or plane stress element. Product: Marc

Siebel CR: 1-287744931

Page 50: Marc 2011 Closed Defects

Fixed in Release: Marc - 2011 Description ( External ): The global creep strain tensor for shell elements and plane stress elements would always be zero.

MARC-1261 Title: Mentat crashes when requesting GIF file Product: Marc

Siebel CR: 1-287758758 Fixed in Release: Marc - 2011 Description ( External ): On Linux machines Mentat occasionally crached when writing a gif file - this appears to be correlated with user doing a resize window event.

MARC-1260 Title: Mesh splitting is incorrect for shells with intersections Product: Marc

Siebel CR: 1-287767841 Fixed in Release: Marc - 2011 Description ( External ): The mesh splitting with user subroutine USPLIT_MESH did not always produce a correct mesh split for shell elements with intersections. Marc assumed and element edge would be connected to only one or two elements. Now up to five intersecting shell elements are allowed.

MARC-1259 Title: Additional load in restart job is not activated. Product: Marc

Siebel CR: 1-287787121 Fixed in Release: Marc - 2011 Description ( External ): An additional load that was applied in a restart job did not get activated. As a workaround the load could already be applied in the previous job as a dummy load.

Page 51: Marc 2011 Closed Defects

MARC-1258 Title: Crack growth with glued contact goes wrong if combined with local adaptivity or mesh splitting Product: Marc

Siebel CR: 1-287788169 Fixed in Release: Marc - 2011 Description ( External ): VCCT based crack propagation with releasing glued contact may go wrong if combined with local adaptivity or mesh splitting. The internally generated deact glue information was lost.

MARC-1252 Title: call of uelastomer in vstener.f Product: Marc

Siebel CR: 1-287893162 Fixed in Release: Marc - 2011 Description ( External ): Sometimes Marc could crash after calls to user subroutine UELASTOMER, when the user had defined some variables for which the definition at the particular call was not really required.

MARC-1249 Title: no function to get option and parameter values of submaterials (e.g. layer thickness) Product: Marc

Siebel CR: 1-288014181 Fixed in Release: Marc - 2011 Description ( External ): Mentat 2010.1.0 Defect in Preprocessing: No database functions were available to get option and parameter values of submaterials (e.g. composite layer thickness, mixture component fraction, rebar layer thickness direction).In previous Mentat versions the database functions material_opt and material_par could be used for this purpose.Five database functions have now been added for materials with a variable number of submaterials (composite, rebar and mixture materials):*) mater_nsubmats(arg1) returns the number of submaterials of material arg1.*) mater_vsubmat_opt(arg1, arg2, arg3) returns the option value of option arg3 for submaterial # arg2 of material arg1.*) mater_vsubmat_par(arg1, arg2, arg3) returns the parameter value of parameter arg3 for submaterial # arg2 of material arg1.*) mater_vsubmat_par_table(arg1, arg2, arg3) returns the name of the table associated with parameter arg3 for submaterial # arg2 of material arg1.*) mater_vsubmat_name(arg1, arg2) returns the name of submaterial # arg2 of material arg1One database function has now been added for materials with a fixed number of submaterials (interface, gasket, pshell and pyrolysis materials):*) mater_fsubmat_name(arg1, arg2) returns the name of submaterial "arg2" of material arg1

MARC-1248

Page 52: Marc 2011 Closed Defects

Title: Mentat crashes when CLT and Post Style 13 are used Product: Marc

Siebel CR: 1-288014457 Fixed in Release: Marc - 2011 Description ( External ): Mentat could crash on postfile revision 13 if elements were present in the model that did not have integration points (like cavity elements). Older post revisions were not affected.

MARC-1244 Title: Does not create rgb file. Product: Marc

Siebel CR: 1-288032361 Fixed in Release: Marc - 2011 Description ( External ): Mentat fails to generate an RGB file if there is a space in the directory name.

MARC-1241 Title: SOIL. EXPONENTIAL option is not correctly read by Mentat Product: Marc

Siebel CR: 1-288072981 Fixed in Release: Marc - 2011 Description ( External ): The SOIL option with an exponential cap model in Marc was not correctly read by Mentat. This had to be explicitly set in Mentat after reading the model.

MARC-1239 Title: In the deact glue area. not all new nodes created from local refinement are added to the list Product: Marc

Siebel CR: 1-288086801 Fixed in Release: Marc - 2011 Description ( External ): Deact glue combined with local adaptivity may go wrong if "hanging nodes" due to the local adaptivity refinement were in the deact glue region.

Page 53: Marc 2011 Closed Defects

MARC-1237 Title: SDRC Product: Marc

Siebel CR: 1-288118246 Fixed in Release: Marc - 2011 Description ( External ): For higher order elements (6-node triangular, 8-node quadrilateral, 10-node tetrahedral and 20-node hexahedral elements), the stress output in a .unv file was based on an incorrect connectivity.

MARC-1232 Title: Marc reader in Mentat cannot read in structural anisotropic material Product: Marc

Siebel CR: 1-288207335 Fixed in Release: Marc - 2011 Description ( External ): The Marc input file reader in Mentat would incorrectly read anisotropic material data which were also referencing tables.

MARC-1231 Title: Marc core dumps with the model that has tyings defined by uformsn or uforms on domain

boundary Product: Marc

Siebel CR: 1-288207721 Fixed in Release: Marc - 2011 Description ( External ): Marc could crash in a parallel DDM analysis if tyings would be defined through user subroutines UFORMS or UFORMSN involving nodes on domain boundaries.

MARC-1230 Title: No temperature increase when coil currents are used in an induction heating analysis Product: Marc

Siebel CR: 1-288210241 Fixed in Release: Marc - 2011

Page 54: Marc 2011 Closed Defects

Description ( External ): Coil currents were ineffective in an induction heating analysis. There were no temperature increases to be observed.

MARC-1228 Title: There is a difference between results (deformation; nodal disp) in t16 and in t19 Product: Marc

Siebel CR: 1-288247051 Fixed in Release: Marc - 2011 Description ( External ): The Mentat formatted postfile reader had a problem with floating point numbers where the exponent part contained 3 digits (1.0e-100 or 1.0e+100). For such numbers the exponent part would be read incorrectly. Binary postfiles were not affected.

MARC-1225 Title: I can not execute a job with user subroutine from mentat. Product: Marc

Siebel CR: 1-288256851 Fixed in Release: Marc - 2011 Description ( External ): Marc jobs could not be run from within Mentat on network shares if they were accessed through their UNC path on Windows (i.e. via \\server\share). This is in fact not possible, but was not properly protected. Mentat will now refuse to submit a job from a UNC path. As a workaround the network drive could be mapped onto a drive letter and then opening the model file on the letter drive, instead of through its UNC path.

MARC-1224 Title: rigid body contact (2D) Product: Marc

Siebel CR: 1-288316831 Fixed in Release: Marc - 2011 Description ( External ): The bottom selection could be wrong in two-dimensional contact jobs with 2D axisymmetric or 2D beam elements in contact with a 2nd order rigid NURBS curve.

MARC-1223

Page 55: Marc 2011 Closed Defects

Title: fixed DOF Spring with nodal transformation Product: Marc

Siebel CR: 1-288316863 Fixed in Release: Marc - 2011 Description ( External ): A fixed DOF spring with transformations at its nodes could give icorrect spring forces.

MARC-1221 Title: exit 13 caused by exclude option Product: Marc

Siebel CR: 1-288425099 Fixed in Release: Marc - 2011 Description ( External ): If the first appearance of the option EXCLUDE would be in the history definition section instead of in the model definition section of a Marc input file, the analysis might have stopped with exit,13. This was likely to happen if the number of edges or faces to be excluded was larger than the number of elements in the model.

MARC-1220 Title: Integer Size option in Mentat 2010 does not work. job hangs after clicking on submit Product: Marc

Siebel CR: 1-288568841 Fixed in Release: Marc - 2011 Description ( External ): Selecting the Integer Size option in Mentat did not work on Windows platforms and the job would hang after clicking on submit. Selecting the Defaults option didn't cause any problems.

MARC-1219 Title: Global to local analysis picking up displacement from wrong contact body Product: Marc

Siebel CR: 1-288589901 Fixed in Release: Marc - 2011 Description ( External ): In the local part of a global to local analysis, some nodes may pick up values from the wrong contact body of the global analysis.

Page 56: Marc 2011 Closed Defects

MARC-1218 Title: HMR File Size...... Product: Marc

Siebel CR: 1-288592911 Fixed in Release: Marc - 2011 Description ( External ): The hypermesh results file (.hmr) could be very large if the model did not contain the CONTROL option in the model definition part of the input.

MARC-1210 Title: Python modules cant be imported Product: Marc

Siebel CR: 1-288745635 Fixed in Release: Marc - 2011 Description ( External ): Certain Python modules cannot be imported into Mentat

MARC-1209 Title: Wear defect Product: Marc

Siebel CR: 1-288749548 Fixed in Release: Marc - 2011 Description ( External ): The mechanical wear option did not work correctly for the exponential models. The signs were not handle properly so incorrect results could be obtained.

MARC-1203 Title: A restart job crashes Product: Marc

Siebel CR: 1-288909341 Fixed in Release: Marc - 2011

Page 57: Marc 2011 Closed Defects

Description ( External ): If in a restart job some tables were not given in the input file, but were being used during the analysis, the restart job would crash. This happened if the restart was done e.g. in the middle of a loadcase, because Mentat would not write the tables for that loadcase.

MARC-1200 Title: solidshell element 185 - comes in a loop during stress recovery - might be related to Hill

material Product: Marc

Siebel CR: 1-288945271 Fixed in Release: Marc - 2011 Description ( External ): A job with Hill plasticity may have a very long time looping during the stress recovery before it exits with an element inside-out message.

MARC-1198 Title: CONTROL OPTION in combination with PORE.1.0 parameter card gives exit 13 Product: Marc

Siebel CR: 1-288958029 Fixed in Release: Marc - 2011 Description ( External ): PORE analysis with only pressure variable (PORE,1,0) could give strange results and strange output, like an unexpect exit 13.

MARC-1195 Title: Opening a model file of a later Mentat version causes crash if it contains unsupported

element types Product: Marc

Siebel CR: 1-288996143 Fixed in Release: Marc - 2011 Description ( External ): Mentat 2010.1.0 General Defect: Mentat could crash upon opening a model file containing elements with unknown element types. This could only occur if the model file had been created with a newer Mentat version.

Page 58: Marc 2011 Closed Defects

MARC-1192 Title: MPI error with NPS Product: Marc

Siebel CR: 1-289008901 Fixed in Release: Marc - 2011 Description ( External ): In some rare cases Marc could crash in a DDM analysis when the AUTO STEP procedure was being used.

MARC-1186 Title: Applied point load is incorrect by new tabel driven in ddm. Product: Marc

Siebel CR: 1-289144081 Fixed in Release: Marc - 2011 Description ( External ): The applied point loads could be incorrect in a DDM analysis if points loads were being applied to nodes on domain boundaries and the table driven input style was being used. This could lead to multiple applications of the point loads to these nodes. The old style input definition of point loads was not affected.

MARC-1180 Title: Definition of gen-aniyld in istropic card gives exit 13 Product: Marc

Siebel CR: 1-289182805 Fixed in Release: Marc - 2011 Description ( External ): The yield criterion GEN-ANIYLD for the ISOTROPIC option has an incorrect description in volume C. Similar to Hill and Barlat it reads an extra line (two for new style input) with YRDIR1 etc.

MARC-1172 Title: print the output of nodal fluxes to a different file Product: Marc

Siebel CR: 1-289352811 Fixed in Release: Marc - 2011 Description ( External ): The PRINT NODE option does not work correctly when writing to a separate file with with an increment frequency

Page 59: Marc 2011 Closed Defects

larger than one.

MARC-1170 Title: Marc core dumps with exporting dmig of brake squeal analysis. Product: Marc

Siebel CR: 1-289386623 Fixed in Release: Marc - 2011 Description ( External ): The Marc 64 bit version could crash while exporting the dmig of a brake squeal analysis when a touching node is a node of a higher order element and the touched face is a face of a lower order element.

MARC-1159 Title: Memory leak occurs with Mumps solver. Product: Marc

Siebel CR: 1-289553395 Fixed in Release: Marc - 2011 Description ( External ): A memory leak has been fixed for the MUMPS solver.

MARC-1154 Title: Marc doesnt run well with in-consecutive numbering and node fill... Product: Marc

Siebel CR: 1-289691648 Fixed in Release: Marc - 2011 Description ( External ): The model definition options NODE FILL, CONN FILL, NODE GENER, NODE CIRCLE, NODE MERGE, CONN GENER, and UFCONN must use consecutive element and node numbering schemes. This was not well documented.

MARC-1149 Title: Mentat crashes when subtracting a curve from a curve with more data points in generalized

XY plotter Product: Marc

Page 60: Marc 2011 Closed Defects

Siebel CR: 1-289902869 Fixed in Release: Marc - 2011 Description ( External ): Mentat terminates in the generalized XY plotter when subtracting a curve from another curve having more data points.

MARC-1137 Title: Scalar Plot NUMERICS may behave differently from CONTOUR BANDS when using

ISOLATE ELEMENTS Product: Marc

Siebel CR: 1-48687621 Fixed in Release: Marc - 2011 Description ( External ): There were problems with numerics and symbol plots in Mentat in combination with isolate elements and post files on which the mesh would change (due to remeshing, element activation/deactivation, etc). If an element set or a contact body would be isolated in a particular increment and the user would skip to another increment with a different mesh, then the elements of the new mesh in that set or body remained isolated, but Mentat would display the non-isolated values of element quantities (usually all zeros) for the nodes of these elements.

MARC-1134 Title: Mentat need a button to set flag to use user subroutines in othrotropic material menu. Product: Marc