MAR SERIES - Lumitron Lightinglumitronlighting.com/file_product/product1333.pdf · 2013. 2. 2. ·...
Transcript of MAR SERIES - Lumitron Lightinglumitronlighting.com/file_product/product1333.pdf · 2013. 2. 2. ·...
-
MA R
MAR SERIESFluorescent Lighting for Hazardous Locations
• Class I, Division 2, Groups A, B, C, & D
• Seismic Tested
• UL 844 Hazardous Locations
• UL 924 Emergency Lighting
• UL 1598A Marine Outside Type
• CSA Certified
• Zone 2, Groups IIA, IIB, IIC
• 55°C Ambient Temperature (265mA T8 only)
• IP66
109
-
110
Fluorescent Lighting for Hazardous LocationsEach MAR Series fixture is individually tested for functional and dielectrical strength at the factory to assure quality
and reliability. This heavy-duty fixture arrives completely assembled.
MAR SERIES
• ConvenientaccesstowiringchamberandthermallyprotectedClassPballast•MarineDutytestingexceedsNEMA4Xrequirementsforhose-downpressureandcorrosiontesting•SeismictestingbyStructuralDynamicsResearchCorporation(fullscaleseismicfragilityqualification)Testedinfrequenciesof1to31.6hertzin3-planeaxiswithmaximumGforceof18.67achieved
Versatilemountingarrangments(360°)
Springloadedsocketsononeendforlampstabilityandmaximumshockandvibrationprotection.265and430mAmodelsmayvaryslightly.
Stainlesssteellenslatchesformaximumstrengthanddurability.
Castaluminumendcapswithmoldedeye-bolthubs.
Streamlinedribbedcorrosion-resistant,copperfreeextrudedaluminumbodyforgreaterheatdissipationandextendedballastlife.
Shatterandheatresistantclearacryliclens.
RIG-A-LITE
Extrudedaluminumlensframeforgreaterstrength.
-
w w w . r i g a l i t e . c o m
Hazardous Locations • Class I, Division 2 • UL 844 • UL 1598A Marine Outside Type • CSA Certified • Wet Locations
FLUORESCENT
111
MAR Series
Catalog Number Logic
MAR 1 2 3 4 5
1 BASIC SERIESMARFluorescentFixtureClassI,Division2,GroupsA,B,C&DUL844HazardousLocationUL1598AMarineOutsideTypeCSACertifiedZone2,GroupsIIA,IIB&IIC55°CAmbientTemperature(265mAT8only)IP66
2 LAMP CURRENT/LAMP WATTAGE800=800mA,60/35Watt430=430mA,34/20Watt(exportonly)425=425mA,40/20Watt(Slimline)265=265mA,32/17Watt(T8Lamps)
3 NOMINAL FIXTURE LENGTH2=2Foot4=4Foot
4 VOLTAGE/FREQUENCYE=12VDC(425mAonly)F=24VDC(425mAonly)G=32VDC(425mAonly)H=347V60HZU=120thru277V50/60HZ
OPTIONS1
TW=EndMounting/ThruWire CableInstallationsOnlyF=SingleFuse2
R=RadioInterferenceFilterL=LampsEM=EmergencyBatteryBackup3
TM=TemperedGlassHL=Hi-LumenBallast(T8Only)EB=EyeBoltOnlySC=SafetyCablewithEyeBolt
1Consultfactoryforpricing.2Fuseoptionnotavailableformarinelistedfixtures.3FixturehousingswithEMoptionarefurnishedwithbaked-ongrayepoxyfinish
Cataloglogicisforexplainingcatalognumberstructureonly.Notallcombinationsarepossible;consultfactoryforcatalognumbersnotlistedincharts.
5
-
112
FLUORESCENT
MAR SeriesHazardous Locations • Class I, Division 2 • UL 844 • UL 1598A Marine Outside Type • CSA Certified • Wet Locations
•ClassI,Division2,GroupsA,B,CandD•UL1598A,UL844•CSACertified•Zone2,GroupsIIA,IIBandIIC•Fordrillingrig,marineandindustriallightinghazardouslocations•Corrosionresistant,lowcoppercontentaluminumtwolampfixture•Availablein265,425,430or800mA•Versatilemountingarrangements,(360°)•Easyaccesstofluorescentballastandinternalwiring•Streamlineddesigngiveseyeappealandruggedness•Designedtowithstandstrongvibration•AvailableinACorDC
32Watt,InstantStartMediumBi-Pin,T8,265mA,48"
34Watt,RapidStartMediumBi-Pin,T12
430mA,48"(exportonly)
40Watt,InstantStartSlimline,T12
48"
60Watt,RapidStartHighOutput,T12
RecessedDoubleContact800mA,48"
17Watt,InstantStart,MediumBi-PinT8,265mA,24"
20Watt,RapidStartMediumBi-Pin,T12
430mA,24"(exportonly)
20Watt,InstantStartSlimline,T12
24"
35Watt,RapidStartHighOutput,T12,RecessedDoubleContact800mA,24"
(Lamps not included)
①Addsuffix“TW”forwirethrumodels
Description
Four FootFixture
Hub Size(inches) Voltage Catalog Number①
3/4
3/4
3/4
3/4
3/4
3/4
3/4
3/4
120-277V50/60HZ
120-277V50/60HZ
12VDC24VDC32VDC
120-277V50/60HZ
120-277V50/60HZ
120-277V50/60HZ
12VDC24VDC32VDC
120-277V50/60HZ
MAR265-4-U
MAR430-4-U
MAR425-4-EMAR425-4-FMAR425-4-G
MAR800-4-U
MAR265-2-U
MAR430-2L-U
MAR425-2-EMAR425-2-FMAR425-2-G
MAR800-2-U
Two FootFixture
Options
RIG-A-LITE
-
w w w . r i g a l i t e . c o m
Hazardous Locations • Class I, Division 2 • UL 844 • UL 1598A Marine Outside Type • CSA Certified • Wet Locations
FLUORESCENT
113
MAR SeriesHazardous Locations • Class I, Division 2 • UL 844 • UL 1598A Marine Outside Type • CSA Certified • Wet Locations
Certification Guide
Coefficients of UtilizationMAR2654U
Candlepower Distribution Photometric Data
80 50 10
50 30 10 50 30 10 50 30 10
20%EffectiveFloorCavityReflectance
.37 .35 .34 .35 .33 .32 .32 .31 .30.32 .29 .27 .30 .28 .26 .28 .26 .25.28 .25 .22 .26 .24 .22 .24 .23 .21.25 .21 .19 .23 .20 .18 .21 .20 .18.22 .18 .16 .21 .18 .16 .19 .17 .15.19 .16 .14 .18 .16 .14 .17 .15 .13.17 .14 .12 .17 .14 .12 .16 .13 .12.16 .13 .10 .15 .12 .10 .14 .12 .10.14 .11 .9 .14 .11 .9 .13 .11 .9.13 .10 .8 .13 .10 .8 .12 .10 .8
% Effective Ceiling Cavity Reflectance
rcc% Wall Reflectance
rwRoom Cavity Ratio
RCR
12345678910
Deg. Parl. 22.5 45 67.5 Norm
0 838 838 838 838 838
5 822 822 822 822 822
15 843 844 847 848 848
25 759 762 765 763 761
35 669 673 673 665 662
45 512 514 508 499 495
55 386 384 373 357 351
65 228 224 207 188 180
75 83 79 621 50 46
85 5 5 5 4 4
90 0 0 0 0 0
MAR 430, 800 25 T6 90MAR 425 40 T6 90MAR 265 55 T4A 90
Model Ambient Temperature °C
Class I, Division 2 Groups A, B, C & D
Supply Wire Suitable Temperature °C
-
114
FLUORESCENT
MAR SeriesHazardous Locations • Class I, Division 2 • UL 844 • UL 1598A Marine Outside Type • CSA Certified • Wet Locations
Fixture Dimensions (inches)
Dimensions (inches) BoxedWeight
Shipping Volume(Boxed Fixtures)MAR SERIES A B C D
4ft.models 52.06 7.38 6.13 1.88 37lbs. 2.0cu.ft.
2ft.models 28.06 7.38 6.13 1.88 27lbs. 1.0cu.ft.
Accessories
Straight Mounting KitCatalogNumber:53033ShippingWeight:5lbs.
Offset Mounting KitCatalogNumber:53032ShippingWeight:5lbs.
Straight Brackets CatalogNumber:26364ShippingWeight:2lbs.
2required
Offset Brackets CatalogNumber:26348ShippingWeight:2lbs.
2required
RIG-A-LITE
-
INSALLATIONS DATA SHEET 53033
STRAIGHT MOUNTING KIT (For MAR Series Fluorescent Fixtures)
Item No. Part No. Description Qty 1 28203 SCREW SQ HD 3/8-16 X 2-1/4 2 2 16503MP BEAM CLAMP 2 3 26364 MOUNTING BRKT STRAIGHT 2 4 28197 SCREW SQ HD 1/4-20 X 1 4 5 28297 SCREW HEX HD 3/8-16 X 1 2 6 10128 SAFETY CABLE 1 7 12026 CORD GRIP 3/4" HUB CABLE RANGE .375-.50 1 8 28180 HEX NUT 3/8-16 1 9 28240 SPLIT LOCK WASHER 3/8 2
10 28209 EYE BOLT 3/8-16 X 1 1
Rig-A-Lite 8500 Hansen Road. • P.O. Box 12942 • Houston, Texas 77217
Phone: (713) 943-0340 • Fax: (713) 943-8354 • E Mail: [email protected]
-
INSTALLATIONINSTRUCTIONS
WARNING!1. TO PREVENT RISK OF ELECTRICAL SHOCK DEACTIVATE/DISCONNECT POWER SUPPLY BE-FORE INSTALLING OR RELAMPING FIXTURE.
2. TO REDUCE RISK OF FIRE OR EXPLOSION, DO NOT INSTALL WHERE THE MARKED OPERAT-ING TEMPERATURE EXCEEDS THE IGNITION TEMPERATURE OF THE HAZARDOUS AT-MOSPHERE(S).
3. THIS FIXTURE SHOULD BE INSTALLED BY QUALIFIED TECHNICIANS IN STRICT ACCOR-DANCE WITH THE NATIONAL ELECTRICAL CODE AND ANY LOCAL REQUIREMENTS.
INSTALLATION FIGURE BTYPICAL CABLE CONNECTIONS TO MAR FIXTURE
1. Refer to Fig. A on page two for installation.
2. For supply connections use wire suitable for at least900C.
3. To make electrical connection using cable, it is notnecessary to open the fixture. The fixture wires areexposed for your convenience. Conn~ct black lead toincoming phase ("hot") line lead, white lead toincoming neutral, and green lead to ground lead.Feed wires into fixture and seal entry with 3/4 in.NPT CG type water tight connector, or equal. (Cableand connectors not supplied). See Fig. B.
FIGURE C
TYPICAL CONDUIT CONNECTIONS TO MAR FIXTURE
4. To make standard electrical connections usingconduit, push wires into hub. Install conduit to thefixture. Unlatch lens frame on both sides of thefixture. Remove lamp. Remove two 10-32 pan headscrews holding the reflector, and remove thereflector, revealing the wiring chamber of the fixture.Connect black, white, and green wires as shown instep three. Replace reflector and lamps. Close lensf~tI.r.ne.See Fig. C.
~ =,:m~.
hAll I R-AHOTCOMOND
r ~I D..~- ...~- ..... I
- i
,~ ~ ~ I! :: IL J
WIRING DIAGRAM
.LRig-A-Lite Partnership, Ltd.
8500 Hansen Road. Houston, Texas 77075Phone: (713)943-0340 . Fax (713) 943-8354. www.rigalite.com
-
~ TYPICALMARSERIESINSTALLATIONSSTRAIGHT MOUNTING KIT
Part Number 53033Includes 2 beam clamps, 2mounting brackets, 1 cord grip, 1safety cable and assorted screws.
?/ ~
OFFSET MOUNTING KIT
Part Number 53032Includes 2 beam clamps, 2mounting brackets, 1 cord grip, 1safety cable and assorted screws.
?,,;
WALL OFFSET MOUNTING BRACKET
Part Number 26348Includes 1 mounting bracket.(2 required)
Il
H
~~.
11//
~I
CEILING MOUNTING BRACKET
Part Number 26364Includes 1 mounting bracket.(2 required)
//
FIGURE A
Rig-A-Lite, Inc. 8500 Hansen Road. Houston, Texas 77075Phone: (713)943-0340 . Fax (713) 943-8354. www.rigalite.com Revised 2007
-
~ TYPICALMARSERIESINSTALLATIONSSTRAIGHT MOUNTING KIT
Part Number 53033Includes 2 beam clamps, 2mounting brackets, 1 cord grip, 1safety cable and assorted screws.
?/ ~
OFFSET MOUNTING KIT
Part Number 53032Includes 2 beam clamps, 2mounting brackets, 1 cord grip, 1safety cable and assorted screws.
?/
WALL OFFSET MOUNTING BRACKET
Part Number 26348Includes 1 mounting bracket.(2 required)
Jl
11
~~,-n
//~
I
CEILING MOUNTING BRACKET
Part Number 26364Includes 1 mounting bracket.(2 required)
//
FIGURE A
Rig-A-Lite, Inc. 8500 Hansen Road. Houston, Texas 77075Phone: (713)943-0340 . Fax (713) 943-8354. www.rigalite.com Revised 2007
INSTALLATIONS_DATA_SHEET_53033.pdfSTRAIGHT MOUNTING KIT