MAP DE Module (ICP‑MAP0007)

3
Intrusion Alarm Systems | MAP DE Module (ICP‑MAP0007) MAP DE Module (ICP‑MAP0007) www.boschsecurity.com u Supports communicator connectivity (including the AT 2000 Transmission System) u Supports DR2020 printer connectivity (current loop) u Provides two RS‑232 COM ports u Provides three supervised and programmable out- puts for sirens, strobes, and other audio‑visual devi- ces u Provides two unsupervised and programmable open‑collector outputs This module is the primary communication interface between the MAP 5000 Main Panel (ICP‑MAP5000) and the communicator including various models of the AT 2000 Transmission System. Functions Communicator Interface The DE module has seven dedicated outputs and two dedicated inputs for connection to a communicator. RS-232 COM Ports The module provides two RS‑232 COM ports: The RS‑232 COM 1 port and the ribbon cable connec- tor for the AT 2000 Transmission System auto dialer are interconnected. The RS‑232 COM 2 port is shared with the 20 mA cur- rent loop on the terminal strip that supports connec- tion to one DR2020 printer through a 6‑position ter- minal block. When a DR2020 printer is connected, the RS‑232 COM 2 port is unavailable. The RS‑232 COM 2 is reserved for future expansion. Notice The open-collector outputs and the printer cannot be used simultaneously. Doing so may cause an over‑current shutdown of either or both the print- er or the outputs. Programmable Outputs Supervised and Programmable Outputs The module provides three polarity‑reversing super- vised programmable outputs. The output voltage is based on the input supply voltage to the module. Su- pervision is provided by a 12.1 kΩ end-of-line (EOL) resistor, and there is a polarity reversing circuit for each of the outputs in the module. Unsupervised and Programmable Open‑collector Out- puts The module provides two unsupervised programmable open‑collector outputs. Installers can use these out- puts to activate an external relay, indicator, solenoid, or other device. Firmware Upgrades The firmware of all devices in the MAP system can be upgraded or updated with the Bosch Remote Program- ming Software (RPS). This allows for on‑site or off‑site (IP through Ethernet) upgrades or updates. Certifications and Approvals The module is designed to comply with the certifications and standards listed here. Region Certification Germany VdS-C G111040

description

MAP DE Module (ICP‑MAP0007)

Transcript of MAP DE Module (ICP‑MAP0007)

Page 1: MAP DE Module (ICP‑MAP0007)

Intrusion Alarm Systems | MAP DE Module (ICP‑MAP0007)

MAP DE Module (ICP‑MAP0007) www.boschsecurity.com

u Supports communicator connectivity (including theAT 2000 Transmission System)

u Supports DR2020 printer connectivity (current loop)

u Provides two RS‑232 COM ports

u Provides three supervised and programmable out-puts for sirens, strobes, and other audio‑visual devi-ces

u Provides two unsupervised and programmableopen‑collector outputs

This module is the primary communication interfacebetween the MAP 5000 Main Panel (ICP‑MAP5000)and the communicator including various models of theAT 2000 Transmission System.

Functions

Communicator InterfaceThe DE module has seven dedicated outputs and twodedicated inputs for connection to a communicator.

RS-232 COM PortsThe module provides two RS‑232 COM ports:

• The RS‑232 COM 1 port and the ribbon cable connec-tor for the AT 2000 Transmission System auto dialerare interconnected.

• The RS‑232 COM 2 port is shared with the 20 mA cur-rent loop on the terminal strip that supports connec-tion to one DR2020 printer through a 6‑position ter-minal block. When a DR2020 printer is connected, theRS‑232 COM 2 port is unavailable. The RS‑232 COM 2is reserved for future expansion.

NoticeThe open-collector outputs and the printer cannotbe used simultaneously. Doing so may cause anover‑current shutdown of either or both the print-er or the outputs.

Programmable OutputsSupervised and Programmable OutputsThe module provides three polarity‑reversing super-vised programmable outputs. The output voltage isbased on the input supply voltage to the module. Su-pervision is provided by a 12.1 kΩ end-of-line (EOL)resistor, and there is a polarity reversing circuit foreach of the outputs in the module.Unsupervised and Programmable Open‑collector Out-putsThe module provides two unsupervised programmableopen‑collector outputs. Installers can use these out-puts to activate an external relay, indicator, solenoid,or other device.

Firmware UpgradesThe firmware of all devices in the MAP system can beupgraded or updated with the Bosch Remote Program-ming Software (RPS). This allows for on‑site or off‑site(IP through Ethernet) upgrades or updates.

Certifications and Approvals

The module is designed to comply with the certifications and standardslisted here.

Region Certification

Germany VdS-C G111040

Page 2: MAP DE Module (ICP‑MAP0007)

Region Certification

Europe CE 2004/108/EC EMC Directive (EMC),2006/95/EC Low-voltage Directive(LVD)

Installation/Configuration Notes

Terminals and Connectors

1

235 4

6

7

8

1. 2 x 4 pin Bosch Data Bus connector

2. 2 x 4 pin Bosch Data Bus connector

3. Three outputs (supervised, programmable)

4. DR2020 Printer Serial Interface

5. Two open‑collector outputs (unsupervised, programmable)

6. COM 2 port

7. COM 1 port

8. Ribbon Cable Connector for AT 2000

Compatibility InformationControl Panels

MAP 5000 Main Panel (ICP‑MAP5000)

Communicator InterfacesThe DE module has seven dedicated outputs and twodedicated inputs for connection to a communicator viathe AT 2000 ribbon cable connector.Printer Interface

Supports DR2020 Printer connectivity – current loop, up to 1000 m(3280 ft) in total length

Parts Included

Quant. Component

1 ICP-MAP0007 MAP DE Module

1 Accessory pack• Three 12.1 kΩ EOL resistors• AT 2000 ribbon cable• Two 4‑pin terminal plugs (green)• Three 2‑pin terminal plugs (orange)• One 3‑pin terminal plug (orange)• One 6‑pin terminal plug (yellow)

1 Literature, Installation Guide

Technical Specifications

Electrical

Operating Voltage: 16 VDC to 29 VDC, 28 VDC nominal

Idle Current Draw: 100 mA maximum

Alarm Current Draw: 150 mA maximum

Programmable Outputs: 5 outputs:• 2 unsupervised and programma-

ble open‑collector outputs able tosink up to a combined current of0.5 A at 28 VDC.

• 3 supervised and programmableoutputs rated at 1 A each.

Mechanical

Dimensions: 146 mm x 159 mm x 76 mm(5.75 in. x 6.25 in. x 3 in.)

Weight: 440 g (1 lb)

Indicator: Green LED for device status

Environmental

Operating Temperature: -10ºC to +55ºC (+14ºF to +131ºF)

Storage Temperature: -20ºC to +60ºC (-4ºF to +140ºF)

Relative Humidity:

5% to 95% (non‑condensing) at the oper-ating and storage temperatures.

Protective System Com-pliant with IEC 60529:

IP 30

Enclosure Protection: IK04 (IEC 62262)

Environmental Class II: EN50130-5, VdS 2110

Use: Intended for indoor use.

Ordering Information

MAP DE ModuleProvides two RS‑232 COM ports; three polarity‑revers-ing supervised programmable outputs for sirens,strobes, and other audiovisual devices; two unsuper-vised programmable open‑collector outputs, and sevendedicated outputs for communicator.Order number ICP-MAP0007

Accessories

AT 2000 Analog, installation moduleFor installation in control panel housing, for analogtransmission of alarm and fault messages via telecom-munication networksOrder number 3002130733

AT 2000 Analog, incl. caseWithout power supply unit, for analog transmission ofalarm and fault messages via telecommunication net-worksOrder number 4998063528

2 | MAP DE Module (ICP‑MAP0007)

Page 3: MAP DE Module (ICP‑MAP0007)

AT 2000 Analog incl. case and power supply unitFor analog transmission of alarm and fault messagesvia the telecommunication networksOrder number 4998063529

AT 2000 AFS, installation moduleFor installation in control panel housing, for analogtransmission of alarm and fault messages via telecom-munication networks, remote-controlledOrder number 3002130734

AT 2000 ISDN, installation moduleFor installation in control panel housing, for transmis-sion of alarm and fault messages via the ISDN tele-phone networkOrder number 3002130732

AT 2000 ISDN, incl. caseWithout power supply, for transmission of alarm andfault messages via the ISDN telephone networkOrder number FMA-AT2000-ISDN

AT 2000 ISDN, incl. case and power supply unitFor transmission of alarm and fault messages via theISDN telephone networkOrder number 4998063532

AT 2000 IP ISDN, installation moduleFor installation in control panel housing, e.g.NZ 300 LSN, for transmitting alarm or fault messagesvia the IP or ISDN networkOrder number ITS-AT2000IP-P

DR 2020 T, Tabletop version including connection com-ponents to BE 2020Order number

3 | MAP DE Module (ICP‑MAP0007)

Represented by:

Americas: Europe, Middle East, Africa: Asia-Pacific: Bosch Security Systems, Inc.130 Perinton ParkwayFairport, New York, 14450, USAPhone: +1 800 289 0096Fax: +1 585 223 [email protected]

Bosch Security Systems B.V.P.O. Box 800025600 JB Eindhoven, The NetherlandsPhone: + 31 40 2577 284Fax: +31 40 2577 [email protected]

Robert Bosch (SEA) Pte Ltd, Security Systems11 Bishan Street 21Singapore 573943Phone: +65 6258 5511Fax: +65 6571 [email protected]

© Bosch Security Systems 2012 | Data subject to change without notice1428050059 | en, V2, 30. Jan 2012