Manual Suavizadores Northstar PA071

Click here to load reader

  • date post

    21-Apr-2015
  • Category

    Documents

  • view

    51
  • download

    0

Embed Size (px)

Transcript of Manual Suavizadores Northstar PA071

P/N: 7243683 (Rev. P 8/25/06)

1

SHIPMENT INSPECTIONThoroughly check the commercial system for possible shipping damage and/or parts loss. Also inspect and note any damage to shipping cartons, crating, etc. If damage is present, notify the transportation company. The manufacturer is not responsible for damage or parts loss in shippment. Note: Do not mistakenly discard small parts bags when unpacking the system. All models are shipped in 3 cartons; (1) resin tank, (2) brine tank, and (3) controller. The mineral bed consists of 1 cubic foot bags of water softening resin, and 17 or 50 pound bags of various grades of gravel. Refer to the following chart.

MODEL

' '

PA0511--1/2 1 (17)

PA0712 1 (17)

PA1013 2 (17)

PA1314 2 (17)

PA1916 1 (50) 1 (50) 1 (50)

PA2518 1 (50) 1 (50) 1 (50)

PA32110 1 (50) 1 (50) 1 (50)

1 CU. FT. BAGS OF RESIN fine BAGS OF GRAVEL medium (LBS) coarse

2

TABLE OF CONTENTSSpecifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Resin Loading and Assembly . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Planning Installation Installation Steps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Inlet -- Outlet Plumbing Drawing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Notes and Cautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Connecting Brine Tank . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Connect Valve Drain Hose . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Pressure Testing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Filling Brine Tank with Water and Salt . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Programming the Controller . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Resetting Time . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Controller Features and Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . FCC Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Operation Demand Controller and Water Meter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Water Flow Through the Conditioner . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Service Information Salt, Recommended Type and Refilling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Removing a Salt Bridge . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Cleaning the Nozzle / Venturi . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Cycle Time / Flow Rate Chart . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Controller Wiring Schematic . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Error Code Table . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Repair Parts Brine Tanks and Brine Valves . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Resin Tanks / Distributor / Controller . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Valve Assembly . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Page No. 4 -- 5 6 7 -- 8 8 -- 9 9 10 10 11 12 12 13--15 16 16--19 18 19 20 -- 22 23 23 23--24 24 25 26 25--28 29--31 32--33 34--35

SAFETY GUIDESFollow the installation instructions carefully. Failure to install the commercial system properly voids the warranty. Before you begin installation, read this entire manual. Then, obtain all the materials and tools you will need to make the installation. Check local plumbing and electrical codes. The installation must conform to them. Use only lead-free solder and flux for all sweat--solder connections, as required by state and federal codes. Do not locate this system where freezing temperatures occur. Do not attempt to treat water over 120F. Freezing, or hot water damage voids the warranty. Avoid installing in direct sunlight. Excessive sun heat may cause distortion or other damage to non--metallic parts. This system requires a minimum water pressure of 30 psi at the inlet. MAXIMUM ALLOWABLE Inlet water pressure is 125 psi. If daytime pressure is over 80 psi, nighttime pressure may exceed the maximum. Use a pressure reducing valve if necessary. (Adding a pressure reducing valve may reduce the flow.) The system works on 24 volt-60 Hz electrical power only. Be sure to use the included transformer. This system is not intended to be used for treating water that is microbiologically unsafe or of unknown quality without adequate disinfection before or after the system.

3

SPECIFICATIONSEQUIPMENT SPECIFICATIONS MODEL TANK SIZE (IN) 4 LBS. CAPACITY (GRAINS) @ SALT USAGE PER CU. FT. RESIN 6 LBS. 8 LBS. 10 LBS. 12 LBS. 5 GPM 10 GPM 15 GPM RECOMMENDED FLOW RATES 20 GPM 25 GPM 30 GPM 35 GPM 40 GPM RESIN (CU. FT.) FINE BAGS OF GRAVEL ( (LBS) ) SALT CAPACITY PIPE SIZE (IN) BACKWASH/FAST RINSE FLOW RATES MEDIUM COURSE 340# 1 3.0 340# 1 1000# 1 7.0 1000# 1 SOFTENERS PA051 12 X 54 25,500 35,365 42,450 46,789 49,540 2.4 nP 6.2 nP 11.4 nP 17.9 nP 25.4 nP 34.2 nP N/A N/A 1.5 1 (17#) PA071 12 X 54 34,000 47,154 56,600 62,386 66,054 2.9 nP 7.3 nP 13.0 nP 20.0 nP 28.6 nP 38.3 nP N/A N/A 2 1 (17#) PA101 17 X 58 51,000 70,731 84,900 93,579 99,081 1.4 nP 4.2 nP 8.0 nP 13.0 nP 19.1 nP 26.5 nP 35.0 nP N/A 3 2 (17#) PA131 17 X 58 68,000 94,308 113,200 124,772 132,108 1.5 nP 4.4 nP 8.6 nP 14.0 nP 20.5 nP 28.3 nP 37.0 nP N/A 4 3 (17#) PA191 24 x 71 102,000 141,462 169,800 187,158 198,162 1.3 nP 3.4 nP 6.9 nP 11.6 nP 17.9 nP 24.0 nP 32.0 nP 41.0 nP 6 1 (50#) 1 (50#) 1 (50#) 1500# 1 PA251 24 x 71 136,000 188,616 226,400 249,544 264,216 1.3 nP 3.6 nP 7.3 nP 12.0 nP 18.4 nP 24.9 nP 33.0 nP 42.2 nP 8 1 (50#) 1 (50#) 1 (50#) 1500# 1 10.0 PA321 24 x 71 170,000 235,770 283,000 311,930 330,270 1.3 nP 3.8 nP 7.6 nP 12.4 nP 19.0 nP 25.6 nP 34.0 nP 43.4 nP 10 1 (50#) 1 (50#) 1 (50#) 1500# 1

psi pressure loss @

continuous flow rates intermittent or peak flow rates flow rates not recommended (hardness leakage, reduced efficiency, etc.)PROGRAMMING INFORMATION

RESIN QUANTITY (CU. FT.) REFILL RATE (GPM) TURBINE SIZE (IN) BACKWASH TIME (MIN) FAST RINSE TIME (MIN) LBS 4, Auto Adj. or Salt Eff. 6 8 10 12

1.50 0.3 1 20 5

2 0.3 1 20 5

3 0.3 1 12 5

4 0.3 1 12 5 MINUTES

6 0.5 1 14 10

8 0.5 1 14 10

10 0.5 1 14 10

108 97 86 74 63

144 129 114 99 84

115 110 105 100 95

160 150 145 135 130

150 145 135 130 125

160 150 145 135 130

180 175 170 160 150

BRINE TIME (MIN) @ SALT DOSE (LBS)

synthetic high capacity resin

4

SPECIFICATIONSEQUIPMENT SPECIFICATIONS FILTERS MODEL TANK SIZE (IN) CONTAMINANT REMOVAL SERVICE WATER FLOW RATE (GPM) 2 GPM 4 GPM 6 GPM 8 GPM 10 GPM 12 GPM 14 GPM 16 GPM 18 GPM MINERAL (CU. FT.) ANTHRACITE FILTER SAND BAGS OF MINERAL (LBS) *Use ( ) only partial bags of l ti l b f supplied mineral GARNET ACTIVATED CARBON MANGANESE GREENSAND GRAVEL BKW/FR FLOW RATES PIPE SIZE (IN) LOCATION (GAL/MIN) FA FB 12 1 1-1/2 30 - 125 35 - 100 24v 60Hz 12 1 1-1/2 30 - 125 35 - 100 24v 60Hz MULTI-MEDIA PA121 12 x 54 based on water analysis 4- 8 1.0 nP 2.3 nP 3.9 nP 5.7 nP 7.9 nP N/A N/A N/A N/A 2 2 (65#)* 1 (52#) 1 (33#)* 2 (17#