Manual de servicio de Inversora V270
-
Upload
taz-juan-g -
Category
Documents
-
view
296 -
download
39
description
Transcript of Manual de servicio de Inversora V270
-
1
W8300009 02/2004
Rev. 0
V270 & V405 CONTROL P.C. BOARD
Part number: W05X0483R
WARNING Be sure that only qualified individuals perform all installation, operation, maintenance and repair procedures. Lincoln Electric is not responsible for damages caused by improper installation, improper care or abnormal operation. Before opening or disassembling any parts of the product, the power must be turned OFF and the product must be disconnected from the input power source. Only Lincoln trained service technicians are authorized to perform these modifications.
-
2
Control P.C. board DIP-SWITCH setup: Read in the appropriate row of the table below the type and the code number written on the rating plate of your machine. The 2nd and the
3rd columns shows the SW1 and SW2 dip-switch setup for each machine type.
Dip-switch SW1
Dip-switch SW2
Machine: 1 2 3 4 5 6 7 8 1 2 3 4
V270-S CE Part number: WF200285 Code: NO CODE, 52014
ON Off Off ON Off Off Off Off ON ON ON Off
V270-T CE Part number: WF200286 Code: NO CODE, 52015
Off Off Off ON Off Off Off Off ON ON ON Off
V270-S AUS Part number: K12002-1 Code: 52005, 52016
ON Off Off ON ON Off Off Off ON ON ON Off
V270-T AUS Part number: K12003-1 Code: 52006, 52017
Off Off Off ON ON Off Off Off ON ON ON Off
V270-S 2V CE Part number: K12004-1 Code: 52007
ON Off Off ON Off Off Off Off ON ON ON Off
V270-T 2V CE Part number: K12005-1 Code: 52008
Off Off Off ON Off Off Off Off ON ON ON Off
V405-S CE Part number: K12000-1 Code: 52003, 52012
ON Off Off ON Off Off Off Off Off Off Off Off
V405-T CE Part number: K12001-1 Code: 52004, 52013
Off Off Off ON Off Off Off Off Off Off Off ON
Control P.C. board TRIMMER setup Verify that the input cord is disconnected from the main supply and the main switch set to OFF. Mount the board on the machine. The machine's output leads must not be connected. On the command panel, set the mode switch to Lift TIG and, if present, the V / A switch to A. Connect the machine to the main supply. Switch ON the machine. On command panel, rotate the Output potentiometer to maximum. On control board, adjust the TR36 trimmer in order to read on the display:
Trimmer TR36 For V270 and V270 2V (all types) For V405 (all types)
270A 400A
Switch OFF the machine and disconnect the input cord from the main supply. Seal the trimmer after calibration. Reassembly the command panel on the machine.
LINCOLN ELECTRIC ITALIA S.r.l Via Fratelli Canepa 8, 16010 Serr Ricc (GE), Italia
www.lincolnelectriceurope.com
Torna Uso: