Atlas Copco Control solutions ES 4i Instruction book

description

Manual de instalación y operación de compresores alemanes Atlas Copco.

Transcript of Manual de compresores Atlas Copco

  • Atlas CopcoControl solutions

    ES 4i

    Instruction book

  • Atlas CopcoControl solutions

    ES 4i

    Instruction book

    Copyright noticeAny unauthorized use or copying of the contents or any part thereof is prohibited.This applies in particular to trademarks, model denominations, part numbers and drawings.This instruction book meets the requirements for instructions specified by the machinerydirective 98/37/EC and is valid for CE as well as non-CE labelled machines.

    2008 - 07No. 2920 7048 01Replaces No. 2920 7048 00www.atlascopco.com

  • Table of contents1 Safety precautions..........................................................................................................4

    1.1 SAFETY ICONS...................................................................................................................................41.2 SAFETY PRECAUTIONS DURING INSTALLATION...........................................................................................41.3 SAFETY PRECAUTIONS DURING OPERATION..............................................................................................51.4 SAFETY PRECAUTIONS DURING MAINTENANCE OR REPAIR...........................................................................6

    2 General description........................................................................................................8

    2.1 INTRODUCTION...................................................................................................................................82.2 LOCAL AREA NETWORK (LAN)............................................................................................................9

    3 Installation instructions...............................................................................................10

    3.1 CONNECTING MACHINES EQUIPPED WITH A MKIV CONTROLLER.................................................................103.2 CONNECTING ATLAS COPCO MACHINES WITH AN ELEKTRONIKON MKI OR MKII REGULATOR...........................123.3 CONNECTING OF ATLAS COPCO MACHINES WITH AN ELEKTRONIKON MKIII REGULATOR.................................123.4 CONNECTING ELECTRO-PNEUMATICALLY CONTROLLED MACHINES AND MACHINES OF OTHER BRANDS.................14

    4 Set-up of the parameters.............................................................................................15

    4.1 INTRODUCTORY REMARKS..................................................................................................................154.2 COMMISSIONING VIA THE DISPLAY........................................................................................................154.3 COMMISSIONING VIA FSP..................................................................................................................17

    5 Operation.......................................................................................................................20

    5.1 REMARKS.......................................................................................................................................205.2 BEFORE STARTING............................................................................................................................205.3 STARTING.......................................................................................................................................215.4 DURING OPERATION..........................................................................................................................225.5 ISOLATION AND RE-INTEGRATION OF A COMPRESSOR...............................................................................235.6 STOPPING.......................................................................................................................................23

    Instruction book

    2 2920 7048 01

  • 6 Integration of a remote pressure sensor....................................................................25

    6.1 CREATING A NEW INPUT.....................................................................................................................256.2 LINK MCC FUNCTIONALITY TO THE EXTERNAL PRESSURE MEASUREMENT....................................................27

    Instruction book

    2920 7048 01 3

  • 1 Safety precautions

    1.1 Safety iconsExplanation

    Danger for life

    Warning

    Important note

    1.2 Safety precautions during installation

    All responsibility for any damage or injury resulting from neglecting these precautions, or non-observance of the normal caution and care required for installation, operation, maintenance and repair,even if not expressly stated, will be disclaimed by the manufacturer.

    General precautions1. The operator must employ safe working practices and observe all related local work safety requirements

    and regulations.2. If any of the following statements does not comply with local legislation, the stricter of the two shall apply.3. Installation, operation, maintenance and repair work must only be performed by authorised, trained,

    specialised personnel.4. Before carrying out any maintenance, repair work, adjustment or any other non-routine checks, stop the

    device. In addition, the power isolating switch must be opened and locked.

    Precautions during installation1. Place the device where the ambient air is as cool and clean as possible.2. During installation or any other intervention on one of the connected machines, the machine must be

    stopped, de-energized and the isolating switch opened and locked before any maintenance or repair. As afurther safeguard, persons switching on remotely controlled machines shall take adequate precautions toensure that there is no one checking or working on the machine. To this end, a suitable notice shall beaffixed to the start equipment.

    3. The electrical connections must correspond to the local codes. The device must be earthed and protectedagainst short circuits by fuses in all phases. A lockable power isolating switch must be installed near thedevice.

    4. For machines controlled by a central control system, a sign stating "This machine may start withoutwarning" must be affixed near the instrument panel.

    5. In multiple compressor systems, manual valves must be installed to isolate each compressor. Non-returnvalves (check valves) must not be relied upon for isolating pressure systems.

    Instruction book

    4 2920 7048 01

  • 6. Never remove or tamper with the safety devices.

    Also consult following safety precautions: Safety precautions during operation and Safetyprecautions during maintenance or repair.These precautions apply to electrical devices.For precautions applying to the connected equipment consult the relevant instruction book.Some precautions are general and cover several machine types and equipment; hence somestatements may not apply to your device.

    1.3 Safety precautions during operation

    All responsibility for any damage or injury resulting from neglecting these precautions, or non-observance of the normal caution and care required for installation, operation, maintenance and repair,even if not expressly stated, will be disclaimed by the manufacturer.

    General precautions1. The operator must employ safe working practices and observe all related local work safety requirements

    and regulations.2. If any of the following statements does not comply with local legislation, the stricter of the two shall apply.3. Installation, operation, maintenance and repair work must only be performed by authorised, trained,

    specialised personnel.4. Before carrying out any maintenance, repair work, adjustment or any other non-routine checks, stop the

    device. In addition, the power isolating switch must be opened and locked.

    Precautions during operation1. Persons switching on remotely controlled machines shall take adequate precautions to ensure that there

    is no one checking or working on the machine. To this end, a suitable notice shall be affixed to the remotestart equipment.

    2. Never operate the device in the presence of flammable or toxic fumes, vapours or particles.3. Never operate the machine below or in excess of its limit ratings.4. Keep all bodywork doors and panels closed during operation. The doors may be opened for short periods

    only, e.g. to carry out routine checks. Wear ear protectors when opening a door if applicable.5. People staying in environments or rooms where the sound pressure level reaches or exceeds 90 dB(A)

    shall wear ear protectors.6. Periodically check that:

    All guards and fasteners are in place and tight All hoses and/or pipes are in good condition, secure and not rubbing There are no leaks All electrical leads are secure and in good order

    7. Never remove or tamper with the safety devices.

    Instruction book

    2920 7048 01 5

  • Also consult following safety precautions: Safety precautions during installation and Safetyprecautions during maintenance or repair.These precautions apply to electrical devices.For precautions applying to the connected equipment consult the relevant instruction book.Some precautions are general and cover several machine types and equipment; hence somestatements may not apply to your machine.

    1.4 Safety precautions during maintenance or repair

    All responsibility for any damage or injury resulting from neglecting these precautions, or non-observance of the normal caution and care required for installation, operation, maintenance and repair,even if not expressly stated, will be disclaimed by the manufacturer.

    General precautions1. The operator must employ safe working practices and observe all related local work safety requirements

    and regulations.2. If any of the following statements does not comply with local legislation, the stricter of the two shall apply.3. Installation, operation, maintenance and repair work must only be performed by authorised, trained,

    specialised personnel.4. Before carrying out any maintenance, repair work, adjustment or any other non-routine checks, stop the

    device. In addition, the power isolating switch must be opened and locked.

    Precautions during maintenance or repair1. Use only the correct tools for maintenance and repair work.2. Use only genuine spare parts.3. A warning sign bearing a legend such as "work in progress; do not start" shall be attached to the starting

    equipment, including all remote start equipment.4. Persons switching on remotely controlled machines shall take adequate precautions to ensure that there

    is no one checking or working on the machine. To this end, a suitable notice shall be affixed to the remotestart equipment.

    5. Never use flammable solvents or carbon tetrachloride for cleaning parts. Take safety precautions againsttoxic vapours of cleaning liquids.

    6. Scrupulously observe cleanliness during maintenance and repair. Keep dirt away by covering the partsand exposed openings with a clean cloth, paper or tape.

    7. Never use a light source with open flame for inspecting the interior of the device.8. All regulating and safety devices shall be maintained with due care to ensure that they function properly.

    They may not be put out of action.9. Before clearing the device for use after maintenance or repair, check that operating pressures, temperatures

    and time settings are correct. Check that all control and shut-down devices are fitted and that they functioncorrectly.

    10. Never use caustic solvents which can damage materials of the air net.

    Instruction book

    6 2920 7048 01

  • Also consult following safety precautions: Safety precautions during installation and Safetyprecautions during operation.These precautions apply to electrical devices.For precautions applying to the connected equipment consult the relevant instruction book.Some precautions are general and cover several machine types and equipment; hence somestatements may not apply to your machine.

    Units and/or used parts should be disposed of in an environmentally friendly and safe manner and inline with the local recommendations and legislation.

    Instruction book

    2920 7048 01 7

  • 2 General description

    2.1 IntroductionES 4i

    Elektronikon II and Elektronikon III regulators of the fourth generation (MkIV) can be used to control up to4 compressors in order to regulate the air net pressure within programmable limits by automatically starting,loading, unloading and stopping the connected compressors.This so-called ES 4i functionality (also referred to as MCC, abbreviation of Multi Compressor Control) is anintegrated feature of the mentioned regulator types. A dongle (part number 8092 2482 62) is required toactivate this extra feature. On the regulator display this function is shown as MCC (Multiple CompressorControl).

    Elektronikon II - MkIV (B controller)

    Elektronikon III - MkIV (D controller)

    Instruction book

    8 2920 7048 01

  • Dongle

    2.2 Local Area Network (LAN)

    The compressors to be controlled must be connected with each other in a Local Area Network (LAN) usingCAN (Controller Area Network) technology.Elektronikon I, Elekronikon II and Elektronikon III regulators (Mk IV) can be directly connected to the localarea network (LAN).The regulator with the integrated ES 4i (MCC) function and the dongle serves as master regulator for thecompressors. The dongle must be connected with the regulator of this compressor, using the free I/O-connection. The regulators of the other compressors act as slave regulators. Elektronikon I regulators can onlyserve as slave.Apart from load/unload controlled compressors, also one VSD (Variable Speed Driven) compressor can beintegrated in the MCC network.Besides Elektronikon Mk IV regulators, also Mk I, Mk II, Mk III and relay-regulated compressors can beconnected to the network by means of a conversion box and/or a communication module between regulatorand network (see the next chapters for details).Select the compressor regulator which will serve as the master regulator for all compressors in the LAN andlabel this compressor as Master Compressor 1.Select the compressor regulator(s) which will serve as slave regulator(s). Label this (these) compressor(s) asCompressor 2, 3 and 4 respectively.More information about how to set-up a compressor network can be found in document 9820 3582 00.

    Instruction book

    2920 7048 01 9

  • 3 Installation instructions

    3.1 Connecting machines equipped with a MkIV controller

    Always stop each compressor and switch off the voltage before making any connection!Remember that Elektronikon I regulators can only act as slave, because they do not have theES 4i feature.In case expansion modules are provided, the dongle must be plugged in into the I/O connectorof the last expansion module.

    Except for the first version of the Elektronikon I (part numbers: see below), all electronic control modules ofthe fourth generation (MkIV), i. e. Elektronikon II or Elektronikon III can directly be connected with eachother using the LAN port as shown in below figure:

    LAN set-up in case of MkIV regulators

    Reference Description Reference Description(1) Compressor 1

    Master(4) Compressor 4

    Slave(2) Compressor 2

    Slave(5) dongle

    (3) Compressor 3Slave

    In case an Elektronikon I regulator of the first version has to be connected to a LAN, the most practical solutionis to replace it by a more recent version (Elektronikon I Plus - part numbers: see below), because hardwiringbetween this version of the Elektronikon I regulator and a master regulator is not possible.

    Instruction book

    10 2920 7048 01

  • Controller with limitedCAN connectionpossibilities

    Part number Used on Replacement controller Part number

    Elektronikon I 1900 0711 01 GA5-90C Elektronikon I Plus 1900 0712 71Elektronikon I 1900 0711 02 GA5-90C Elektronikon I Plus 1900 0712 71Elektronikon I 1900 0711 03 GA5-90C Elektronikon I Plus 1900 0712 71Elektronikon I 1900 0711 06 GA5-90C Elektronikon I Plus 1900 0712 71

    Elektronikon I regulator - MkIV (A controller)

    Elektronikon II regulator - MkIV (B controller)

    Elektronikon III regulator - MkIV (D controller)

    Instruction book

    2920 7048 01 11

  • 3.2 Connecting Atlas Copco machines with an Elektronikon MkI orMkII regulator

    There are two ways to connect an Atlas Copco machine fitted with either Elektronikon MkI or MkII to themaster regulator with the built-in ES 4i feature: Connect a ComBox S (part number 8092 2482 54) to the Elektronikon module and connect the ComBox

    S to the LAN. Use a CANBox interface (part number 1900 0712 61) to connect with the Elektronikon and connect the

    CANBox Interface with the LAN.

    Connecting Elektronikon MkI or MkII to a LAN

    Reference Description Reference Description(1) LAN (4) Elektronikon MkI or MkII(2) CANBox interface (5) COMBox S(3) hardwired connection

    3.3 Connecting of Atlas Copco machines with an ElektronikonMkIII regulator

    This generation of the Elektronikon regulator came in two variants: a Low Range and a High Range version.One of the key differences between these two regulators are the communication possibilities. The detailsbelow explain the possibilities for each variant. Elektronikon MkIII Low Range regulator (part number 1900 0700 0x):

    There are two connection possibilities for this regulator:

    Instruction book

    12 2920 7048 01

  • Via a CANBox interface (part number 1900 0712 61), which in turn is connected to the LAN tocommunicate with the ES 4i master regulator (see the figure below)

    hardwired directly to the ES 4i master regulatorIn both cases some simple changes are required inside the electrical cubicle. More specifically, two relaysmust be added, one for the signal running status and the other for the signal load/unload status.

    Elektronikon MkIII High Range regulator (part number 1900 0701 0x).Here also are two possibilities: The regulator includes an extra module known as COM 1

    The easiest way to connect the machine to the ES 4i master is to add a ComBox S interface (partnumber 8092 2482 54) which converts all communications to the LAN.

    Alternatively the compressor can be hardwired directly to the ES 4i. If the machine does not include a COM 1 module there are two possibilities:

    Use both a COM 1 (part number 8104 0115 00) and a ComBox S (part number 8092 2482 54) Use a CANBox interface (part number 1900 0712 61).

    Connecting MkIII regulators to a LAN

    Instruction book

    2920 7048 01 13

  • Reference Description Reference Description(1) LAN (5) Elektronikon MkIII - Low Range

    regulator(2) CANBox interface (6) Elektronikon MkIII - High Range

    regulator without COM1(3) ComBox S (7) RS232 connection(4) hardwired connection (8) Elektronikon MkIII - High Range

    regulator with COM1

    3.4 Connecting electro-pneumatically controlled machines andmachines of other brands

    The only way to connect this type of machines to the regulator with the activated ES 4i function is to use aCANBox interface (part number 1900 0712 61) , which in turn is connected to the LAN network viahardwiring.

    Connecting electro-pneumatically controlled machines to the LAN

    Reference Description Reference Description(1) LAN network (3) hardwired connection(2) CANBox interface (4) Elektro-pneumatically controlled

    machine or non- Atlas Copco machine

    The connections between the CANBox interface(s) and the master regulator are made using the LAN ports,in exactly the same way as MkIV regulators are connected (see Connecting machines equipped with a MkIVcontroller).

    Instruction book

    14 2920 7048 01

  • 4 Set-up of the parameters

    4.1 Introductory remarks

    There are two ways to modify the ES 4i (MCC) parameters in the regulators: via the display via FSP (Field Service Program) software. This is specific software, available to the Atlas Copco

    Aftermarket Department. Contact your Atlas Copco Customer Centre for details.However, some modifications are only possible via the display, while some other modifications are onlypossible via FSP. Consult the survey at the end of this chapter.

    Always stop the compressor before making changes to the settings.

    4.2 Commissioning via the displayActivating the ES 4i (MCC) function in the master regulator

    From the main screen, press and hold the arrow up key (1) for 3 seconds. The following screen is displayed:C.C.M. Remote Control Service Main Mod F1 F2 F3

    Next, press the arrow down key (1) until the option M.C.C. is shown. By default, the text Not Activatedis blinking.

    Press the F2 key (Mod) to modify . Use the arrow up or down key (1) to change the setting. With Activated blinking, Press F1 (Prog) to save the modification. Use the F1 key to go back to the min menu

    Instruction book

    2920 7048 01 15

  • Selection of the number of compressors in the LAN

    From the main screen, press F1 (Menu) In the next screen, use the arrow keys (1) to scroll until the option Modify Params is shown Use the tab key (2) to select Modify Params Use the arrow keys (1) until option Parameters MCC is shown and press the tab key (2) to select. Press F2 (Mod) to modify. On the screen, number 1 is blinking Use the arrow keys (1) to change the number of compressors in the LAN Press key F1 (Prog) to save the selected value:Number Of Compr

    1

    Prog Lim Canc F1 F2 F3

    Use the F1 key to go back to the main menu

    Programming the node ID number and activation of the LAN for master and slave regulators

    Repeat following steps for each slave regulator: Switch on the voltage From the main menu, press the F1 key (Menu) Use the arrow down keys (1) until the option Modify params, followed by a horizontal arrow is shown.

    Press the tabulator key (2) to activate this menu. Press the arrow down key (1) until option Configuration is followed by a horizontal arrow on the screen.

    Press the tabulator key to activate this menu and scroll down to the option C.C.M.. The next screenappears:

    Instruction book

    16 2920 7048 01

  • C.C.M. LAN control

    Menu Mod Canc F1 F2 F3

    Press key F2 (Mod) to modify and use the arrow keys (1) to select LAN control. To be recognizablein the LAN, each slave regulator must have a unique compressor node address.

    In the configuration menu of each slave regulator, scroll to the option Node ID. Press key F2 (Mod)and use the arrow up/down keys (1) to select the number. Press the corresponding function key (Prog)to confirm the modification.

    It is recommended to set the master regulator as number 1 in the configuration. Each slave regulator needs tobe programmed separately by repeating the above describes actions. Select node ID 2 for compressor 2, nodeID 3 for compressor 3 and node ID 4 for compressor 4.

    4.3 Commissioning via FSPProgramming the MCC parameters in the master regulator via FSP

    With the Mk IV FSP software , it is possible to change the MCC Master and activate the MCC function.Always use the latest version of the software!The path to this receipt is: Standard settings\MCC status

    Double-click on the receipt MCC Status to open the dialog window:

    Next, change the status. There is a choice between following options: None Exists but non active Exists and is activeSelect Exists and is active, save and close the dialog window to change the settings.

    Instruction book

    2920 7048 01 17

  • Survey of parameters that can be changedParameter Function min

    valueexfactorysetting

    maxvalue

    unit Note

    Number OfCompr

    to program the number of compressorsconnected to the LAN

    1 1 4 - (1)

    System Stop to allow the master regulator to stop allconnected compressors or not

    - enabled - - (4)

    SystemForced

    to allow the master regulator to forceanother sequencing by starting a newcompressor at the interval programmed inparameter forced time

    - enabled - - (4)

    Pres BandSel

    to select between two different systempressure bands (pressure band 1 and 2)

    - activated

    - -

    running hours1

    to enter running hours for compressor 1 toinfluence the MCC control algorithm

    0 0 65535 hrs

    running hours2

    to enter running hours for compressor 2 toinfluence the MCC control algorithm

    0 0 65535 hrs

    running hours3

    to enter running hours for compressor 3 toinfluence the MCC control algorithm

    0 0 65535 hrs

    running hours4

    to enter running hours for compressor 4 toinfluence the MCC control algorithm

    0 0 65535 hrs

    Min presband 1

    to program the minimum setting forpressure band 1

    4.0 7.0 bar(e) (3)

    Max presband 1

    to program the maximum setting forpressure band 1

    (3) 8.0 (3) bar(e)

    Min presband 2

    to program the minimum setting forpressure band 2

    4.0 (3) 7.0 (3) bar(e)

    Max presband 2

    to program the maximum setting forpressure band 2

    (3) 8.0 (3) bar(e)

    C1 starts/day to program the number of starts per day forcompressor 1 (Node 1)

    3 240 720 -

    C2 starts/day to program the number of starts per day forcompressor 2 (Node 2)

    3 240 720 -

    C3 starts/day to program the number of starts per day forcompressor 3 (Node 3)

    3 240 720 -

    C4 starts/day to program the number of starts per day forcompressor 4 (Node 4)

    3 240 720 -

    Forced time to program the interval at which, if activatedby parameter system forced, the masterstarts a new compressor in case nosequence change has occured during theinterval

    1(2) 7 (4) 60(2) days (2)

    Rem to loc T to program the time interval betweenremote to local commands from the masterregulator to the slave regulators

    5(2) 20(4) 600 (2) s

    Starts react T to program the time interval between whichthe start commands from the master shouldresult in loaded running of compressors

    10 15 60 s

    Instruction book

    18 2920 7048 01

  • Parameter Function minvalue

    exfactorysetting

    maxvalue

    unit Note

    Start time to program the time interval between thedifferent start and load commands frommaster regulator to slave regulators

    5 20 600 s

    Delta time to program the difference in running hoursto allow the master to decide starting /loading another compressor

    10(2) 168 (4) 672 (2) hrs

    Stop react T to program the time interval between whichthe stop command from the master shouldresult in stopping the compressor

    5 (2) 35 (4) 120 (2) s

    Unload time to program the time interval betweendifferent unload commands from themaster to the slave regulators

    2 (2) 5 (4) 60 (2) s

    Notes:(1): can only be modified via the display of the regulator(2): can only be modified via FSP software(3): can only be modified via FSP (full access required)(4): can be modified via the display and via FSP

    To change the settings in FSP, use the following path:Standard settings \ MCC Settings:

    Instruction book

    2920 7048 01 19

  • 5 Operation

    5.1 RemarksLocal start/stop function

    All local start and stop functions on the control panels of the compressors are disabled, except for theemergency stop buttons which remain active.

    Clock functionsIn case time-based automatic start/stop commands were programmed in the regulators of the participatingcompressors (via menu Clock function), these commands will not be taken into account.

    Variable Speed Driven CompressorsIn case a VSD compressor is participating, it will start first and the set point and stop levels will change asfollows: The set point will be in the middle of the net pressure band. The Indirect stop level will equal the maximum level of the net pressure band. The Direct stop level will equal the sum of the new Set point and the programmed direct stop level of the

    VSD compressor; the direct stop level must be higher than the Indirect stop level.Example:Pressure band levels programmed in the master regulator: max. 8.0 bar(e) - min. 7.0 bar(e) and Direct stoplevel programmed in the regulator of the variable speed compressor: 1 barIn LAN configuration, the VSD compressor will have a Set point of 7.5 bar(e), an Indirect stop level of 8.0bar(e) and a Direct stop level of 8.5 bar(e).

    5.2 Before startingType III controller

    When switching on the voltage (or if no key is pressed during 4 minutes), the Main screen will be shown onthe master regulator. Press the F2 button to show the MCC screen, of which an example is shown here:

    The screen in above example shows: The master (compressor 1) runs load

    Instruction book

    20 2920 7048 01

  • Compressor 2 is stopped Compressor 3 shows no communication between the master regulator and the related slave regulator Compressor 4: the related compressor is shut down The maximum pressure is 8.0 bar The minimum pressure is 7.0 bar

    The related compressor runs load

    The related compressor runs unloadThe related compressor is stoppedThe related compressor is shut down

    !!

    The related compressor is not reacting on a command from the master regulator

    ??

    No communication between master regulator and the related slave regulator

    XX

    The related compressor is not recognized

    If one of the compressors is a VSD compressor, a speed bar indicator will be shown.If one of the compressors is not reacting on a command from the master regulator, Rset will be shown inthe main screen:

    Rset (reset) can be used to reset the communication between master and slave regulators, e.g. after integratinga compressor. See Isolation and re-integration of a compressor.

    5.3 Starting

    After pressing the start button, the master regulator with the activated ES 4i (MCC) functionality will start,load, unload and stop the compressors in the network as needed to keep the net pressure between theprogrammed pressure bands, while taking into account the programmed parameters.

    Instruction book

    2920 7048 01 21

  • 5.4 During operationType III controller

    If the master regulator is a type III controller, the MCC main screen will be similar to the one below:

    The screen in above example shows: Compressor 1 (master regulator) runs loaded Compressor 2 is stopped Compressor 3: no communication between regulator and related slave Compressor 4: the related compressor is not reacting The maximum pressure is 8.0 bar The minimum pressure is 7.0 bar

    After pressing the arrow down button the following screen will be shown:

    This screen shows: The net pressure is 8.0 bar The master regulator is regulating the compressors connected to the LANThe Stop key (F2) can be used to stop all compressorsThe Loc key (F3) can be used to switch the compressors back to local controlUse the arrow up button to go back to the previous screen.

    After pressing the Main key in the MCC main screen the screen below will be shown:

    Instruction book

    22 2920 7048 01

  • The compressor main screen shows: The compressor outlet pressure is 7.5 bar The compressor is running loaded and is connected to a LAN The Menu key (F1) can be used to scroll through the menus of the master compressor, e.g. to call up data

    of the compressor The MCC key (F2) can be used to return to the MCC main screen

    5.5 Isolation and re-integration of a compressorIsolation of a compressor

    It is possible to isolate a compressor from the regulation by the master regulator.1. On the regulator of the compressor to be isolated, press the key Menu and scroll to menu Configuration.2. Scroll to option CCM (compressor control mode), press the key Mod and use the arrow up or arrow down

    keys to select Local; press the Prog key to program it. The compressor will be isolated; the correspondingcompressor number will blink on the control panel of the master regulator.

    Re-integration of a compressorTo re-integrate an isolated compressor:1. On the regulator of the compressor to be re-integrated, press the key Menu and scroll to menu

    Configuration.2. Scroll to option CCM (Compressor Control Mode), press key F2 and use the arrow up or arrow down keys

    to select LAN. Press the Prog key (F1) to program it.3. Press the key Rset on the MCC screen of the master regulator. The master regulator will take over the

    pressure regulation of the integrated compressor.

    5.6 StoppingType III controller

    If the master regulator is a type III controller, press Function key F2 (Stop) in following screen to stop allcompressors connected to the LAN:

    Instruction book

    2920 7048 01 23

  • See During operation for more details.

    Instruction book

    24 2920 7048 01

  • 6 Integration of a remote pressure sensor

    6.1 Creating a new inputIntroduction

    By default, the MCC master regulates the compressors based on its own compressor outlet pressure, i.e. thepressure measured by the pressure sensor in the master compressor. It is however also possible to use anotherinput device (a remote pressure sensor) as the regulation input.Creating a new input can be done using the service and commissioning software (FSP) for MkIV. For moredetails, see the FSP user manual (can be found via LN in the Elektronikon Software Market database).After creating the remote sensor input, the MCC function must be linked to this input. This can be done usingthe same service and commissioning software (FSP) for MkIV.

    Creating a new input for a Kavlico pressure transducerIf no spare inputs are available on the Master Module, first an AIE1 expansion module must be linked to themaster module. The AIE1 module (part number 1900 0710 41) adds 2 pressure inputs to the MkIV controller.

    Important note: before physically connecting expansion modules, switch off the power, thesame way as for connecting the MCC dongle!

    Instructions for FSP: Activate the Advanced or Full Access level. Click on the box before AIE1/AIE2 Expansion and select the type of expansion box. Be sure that the

    compressor is on local control.

    => Add a pressure input function:

    Next, select System pressure from the list and click OK:

    Instruction book

    2920 7048 01 25

  • Next, enter text to define the input and program this data by clicking on the Save button:

    On the MkIV regulator, you can now check the new pressure input:The Extra information screen of the master regulator now shows D 2 K where D=type of master module,2=AIE1 expansion module and K=MCC dongle. In the list of Measured data the input Net Pressure isindicated.

    Creating a new input for a pressure transmitterIt is also possible to use a pressure transmitter as pressure sensing device. In this case, first an AIE2 expansionmodule must be linked to the master module. The AIE2 module (part number 1900 0710 52) adds 4 transmitterinputs to the MkIV controller. Remember that transmitters must always be powered by an external supply.

    Important note: before physically connecting expansion modules, switch off the power, thesame way as for connecting the MCC dongle!

    Instructions for FSP: Activate the Advanced or Full access level Click on the box before AIE1/AIE2 Expansion => select the type of expansion box.

    Add a pressure input function

    Instruction book

    26 2920 7048 01

  • Next, select System pressure from the list and click OK:

    Next, enter text to define the input and program this data by clicking on the Save button:

    On the MkIV regulator, you can now check the new pressure input:The Extra information screen of the master regulator now shows e.g. D 3 K where D=type of master module3=AIE2 expansion module and K=MCC dongle.In the list of Measured data the input Net Pressure is indicated.

    6.2 Link MCC functionality to the external pressure measurement

    After creating the remote sensor input, the MCC function must be linked to this input.Instructions for FSP: Activate the Advanced or Full access level Select the new input as the input used for MCC in the MCC status data

    Instruction book

    2920 7048 01 27

  • Select the correct status (MCC active, System Stop enabled/disabled,...) and program these data by clickingthe Save icon:

    Instruction book

    28 2920 7048 01

  • No. 2

    920 7

    048 0

    1 / 20

    08 - 0

    7 - Pr

    inted

    in B

    elgium

    In order to be First in Mind-First in Choice for all your qualitycompressed air needs, Atlas Copco delivers the products andservices that help to increase your business efficiency andprofitability.Atlas Copco's pursuit of innovation never ceases, driven by ourneed for reliability and efficiency. Always working with you, we arecommitted to providing you the customized quality air solution thatis the driving force behind your business.

    www.atlascopco.com

    Table of contents1 Safety precautions1.1 Safety iconsExplanation

    1.2 Safety precautions during installationGeneral precautionsPrecautions during installation

    1.3 Safety precautions during operationGeneral precautionsPrecautions during operation

    1.4 Safety precautions during maintenance or repairGeneral precautionsPrecautions during maintenance or repair

    2 General description2.1 IntroductionES 4i

    2.2 Local Area Network (LAN)

    3 Installation instructions3.1 Connecting machines equipped with a MkIV controller

    3.2 Connecting Atlas Copco machines with an Elektronikon MkI or MkII regulator

    3.3 Connecting of Atlas Copco machines with an Elektronikon MkIII regulator

    3.4 Connecting electro-pneumatically controlled machines and machines of other brands

    4 Set-up of the parameters4.1 Introductory remarks

    4.2 Commissioning via the displayActivating the ES 4i (MCC) function in the master regulatorSelection of the number of compressors in the LANProgramming the node ID number and activation of the LAN for master and slave regulators

    4.3 Commissioning via FSPProgramming the MCC parameters in the master regulator via FSPSurvey of parameters that can be changed

    5 Operation5.1 RemarksLocal start/stop functionClock functionsVariable Speed Driven Compressors

    5.2 Before startingType III controller

    5.3 Starting

    5.4 During operationType III controller

    5.5 Isolation and re-integration of a compressorIsolation of a compressorRe-integration of a compressor

    5.6 StoppingType III controller

    6 Integration of a remote pressure sensor6.1 Creating a new inputIntroductionCreating a new input for a Kavlico pressure transducerCreating a new input for a pressure transmitter

    6.2 Link MCC functionality to the external pressure measurement