AGROSIZE®Touchscreen A digital caliper / sizer By Agro Technologie Version October 2013
APOLLINAIRE Ltd - AGRO TECHNOLOGIE Dept Zone Industrielle – 76440 FORGES LES EAUX - FRANCE
[email protected] - www.agro-technology.co.uk – Tel +33 6 83181720
Sorting, grading and sizing fruits and vegetables... Agrosize® registers the size / caliper, and makes statistics It is a laboratory
grading system for fruits and vegetables
Completely designed and manufactured in France by Apollinaire Ltd – Agro Technologie Department
AGROSIZE®Touchscreen A digital caliper / sizer By Agro Technologie Version October 2013
APOLLINAIRE Ltd - AGRO TECHNOLOGIE Dept Zone Industrielle – 76440 FORGES LES EAUX - FRANCE
[email protected] - www.agro-technology.co.uk – Tel +33 6 83181720
1) RECOMMANDATIONS
- Agrosize®Touchscreen is a precision instrument, avoid falls and shocks - Agrosize®Touchscreen is not waterproof ! Keep it clean from any fruit juice or water - Agrosize®Touchscreen is guaranteed 2 years from the date of shipment
2) SPECIFICATIONS
Congratulations for having acquired an Agrosize®Touchscreen!
Your box contains: - The device itself composed by the Touchscreen console, and the sensor The software backup (On a
CD) - The manual - A certificate of conformity - A charger - A CD for operating system recovery - A stilet - 2 batteries : one of 6000 mAh and one of 3000 mAh
The Agrosize®Touchscreen has been completely designed and assembled in France. The electronic card
has been manufactured through a highly robotized process.
The Agrosize®Touchscreen waterproof ! It is a precision instrument, avoid falls and shocks
The Agrosize®Touchscreen is guaranteed 2 years from the date of shipment
- Resolution : +/- 0.1 mm - Precision : +/- 0.5 mm - Time of load : 2 hours for an autonomy of 9 hours (Normal use) - Li-Ion polymer battery by Cameron Sino : 6000 mAh 7.2 V - Touchscreen console by Archos - Working under Windows 7 starter (The software starts immediately when turning on, and registers
parameters automatically when turning off the device – You don’t have to use Windows interface…) - 1 GB Ram - 32 GB hard disk - Intel inside
AGROSIZE®Touchscreen A digital caliper / sizer By Agro Technologie Version October 2013
APOLLINAIRE Ltd - AGRO TECHNOLOGIE Dept Zone Industrielle – 76440 FORGES LES EAUX - FRANCE
[email protected] - www.agro-technology.co.uk – Tel +33 6 83181720
3) STARTING
- Press 3 seconds on this button :
- A blue Led switches on - Windows starts - The software starts automatically as well
- This window appears :
AGROSIZE®Touchscreen A digital caliper / sizer By Agro Technologie Version October 2013
APOLLINAIRE Ltd - AGRO TECHNOLOGIE Dept Zone Industrielle – 76440 FORGES LES EAUX - FRANCE
[email protected] - www.agro-technology.co.uk – Tel +33 6 83181720
- Take the stillet on back side :
- Open the foot of the instrument in order to put it on a table :
AGROSIZE®Touchscreen A digital caliper / sizer By Agro Technologie Version October 2013
APOLLINAIRE Ltd - AGRO TECHNOLOGIE Dept Zone Industrielle – 76440 FORGES LES EAUX - FRANCE
[email protected] - www.agro-technology.co.uk – Tel +33 6 83181720
- With the stillet, click in the field « Batch name » - Press on this button in order to open the keyboard - Enter the name of the batch, and click again on the keyboard button in order to remove the keyboard
- In order to switch off the instrument, close the software using the following button :
AGROSIZE®Touchscreen A digital caliper / sizer By Agro Technologie Version October 2013
APOLLINAIRE Ltd - AGRO TECHNOLOGIE Dept Zone Industrielle – 76440 FORGES LES EAUX - FRANCE
[email protected] - www.agro-technology.co.uk – Tel +33 6 83181720
4) MEASURING WITHOUT REGISTERING
- First click on the button “Zero” in order to initialize the instrument - Just move slowly the fruit you want to measure along the square, and cross the door - The maximum is displayed in the fields “Inch”, “mm” and “row”
5) MEASURING & REGISTERING A BATCH
- First click on the button “Zero” in order to initialize the instrument - Enter the name of your batch in the field “Batch” - Enter the type of fruits you are going to measure (optional) - The button “Start” appears, click on it – It disappears and the button “End” appears
AGROSIZE®Touchscreen A digital caliper / sizer By Agro Technologie Version October 2013
APOLLINAIRE Ltd - AGRO TECHNOLOGIE Dept Zone Industrielle – 76440 FORGES LES EAUX - FRANCE
[email protected] - www.agro-technology.co.uk – Tel +33 6 83181720
- Cross the door slowly with your fruits one after each other, the size is automatically
displayed in the list
- Don’t forget to click on “End” when you have finished your batch, otherwise the batch will not be registered
- A graph is displayed
AGROSIZE®Touchscreen A digital caliper / sizer By Agro Technologie Version October 2013
APOLLINAIRE Ltd - AGRO TECHNOLOGIE Dept Zone Industrielle – 76440 FORGES LES EAUX - FRANCE
[email protected] - www.agro-technology.co.uk – Tel +33 6 83181720
- If you want to cancel the last measurement, click on “Cancel” – The data displayed becomes red, and stays red till you make a number of new measurements equivalent to the ones you have cancelled – Otherwise, the statistic data are false (Average, Deviation, H Index)
6) BATCHES CONSULTATION
- Click on “Access to Batches” in order to reach the batches consultation window - You can classify the batches by fruit or by batch name by clicking on the top of each column. - You can delete the corresponding batch, or open corresponding files - All batches are available in the folder “C:\AGROSTASAVE” under .csv extension (Compatible
with Excel)